Introduction
S.L.A. Surface 04
SimpleLine II Characteristics 06
SimpleLine II Color Coding by Diameter 07
SimpleLine II Fixture 08

Surgical Components
Cover Screw & Healing Abutment 10

Prosthetic Procedure 1
Solid / Dual / SCA Abutment 12
Solid Abutment 13
Dual Abutment 14
Abutment Level Impression Components- Solid / Dual Abutment 15
SCA Abutment 16
Abutment Level Impression Components- SCA Abutment 17
Restorative Kit 18
Prosthetic Procedure 2
Dual / SCA / Dual Milling / Angled / Direct-Casting Abutment / Metal-Casting Abutment 19
Fixture Level Impression Components 20
Dual Milling / Angled / Direct-Casting / Metal-Casting Abutment 21
Temporary Abutment(Ti / Plastic) / Analog 24
Prosthetic Procedure 3
Screw Abutment 26
Screw Abutment 27
Screw Abutment Impression Components 28
Prosthetic Procedure 4
Overdenture Procedure - Positioner / Ball / Magnetic Attachment 32
Positoner 33
Mini Ball Attachment 35
Magnetic Attachment 36

Instruments­­­­­
SimpleLine II Surgical Kit 37
Drill 38
Instrument 39
Prosthetic Kit 41
Prosthetic and Laboratory Instrument 42

Surgical Manual 44
Prosthetic Manual 49
4 SimpleLine ll Product Catalog

S.L.A. Surface
S.L.A. (Sandblasting with large grit and acid etching)
•   Higher bone-to-implant contact.
•   Faster bone formation on the surface.

In vivo test
SimpleLine ll Product Catalog 5
6 SimpleLine ll Product Catalog

SimpleLine II Characteristics

SCA Abutment

• Offers additional gingival height options


Ti-Retaining Screw
• Implantation with the SCA Abutment
• Smaller diameter of abutment screw has • Able to reproduce emergence profile
reduced a tendency of falling off a resin in • Effective soft tissue management
the screw hole.
• More stable occlusal scheme

Ø2.0mm

4.8mm

Ø1.6mm
8 degree Morse Taper Octagon
Connection

• Screw loosening is well prevented due


to the cold welding mechanism for solid
abutment application.
• Maximized depth of the octagon design
to enable easy adaptation verification
Double-threaded Design for dual abutment application.

• Sharpened thread design promotes


better initial stability in soft bone
• Easy & fast insertion can be done due to
double threaded straight body design

0.4
SimpleLine ll Product Catalog 7

SimpleLine II Color Coding by Diameter

Color Coding by Diameter

• Cover screw is not included in the packaging. (Unit: mm)

Cap Color

Yellow Green Sky Blue Brown Red

Fixture
SimpleLine II
(Mount Free)

A
Platform 4.8 4.8 4.8 6.5 6.5
Diameter

D
B
Body 3.4 3.8 4.3 4.3 4.8
Diameter

C
Bevel Height 0.55 0.55 0.55 0.75 0.75

D
Gingival 2.0 2.0 2.0 2.0 2.0
Height
8 SimpleLine ll Product Catalog

SimpleLine II Fixture
Unit: mm, Scale 1 : 1.5 / mm

Ø4.8
Platform Ø4.8 | Body Ø3.4 0.55 08 10 12
G/H 2.0
L Art. No.
08 SOFX 4834 08 R
L
10 SOFX 4834 10 R
12 SOFX 4834 12 R

Ø3.4

Ø4.8
Platform Ø4.8 | Body Ø3.8 08 10 12
0.55
G/H 2.0
L Art. No.
08 SOFX 4838 08 R
10 SOFX 4838 10 R L

12 SOFX 4838 12 R

Ø3.8

Ø4.8
Platform Ø4.8 | Body Ø4.3 08 10 12
0.55
G/H 2.0
L Art. No.
08 SOFX 4843 08 R
L
10 SOFX 4843 10 R
12 SOFX 4843 12 R

Ø4.3
SimpleLine ll Product Catalog 9

SimpleLine II Fixture

Ø6.5
Platform Ø6.5 | Body Ø4.3
0.75 08 10 12
L Art. No. G/H 2.0

08 SOFX 6543 08 R
L
10 SOFX 6543 10 R
12 SOFX 6543 12 R

Ø4.3

Ø6.5
Platform Ø6.5 | Body Ø4.8
0.75 08 10 12
L Art. No. G/H 2.0

08 SOFX 6548 08 R
L
10 SOFX 6548 10 R
12 SOFX 6548 12 R

Ø4.8
10 SimpleLine ll Product Catalog

Cover Screw
Unit:mm, Scale 1: 1.5 / mm

Ø 3.5­­­­­­­­

SOCS4835 and SOFX483810R

Cover Screw | Single use only

Application Diameter Art. No. Ø3.5 Ø4.3


Ø4.8 Ø3.5 SOCS 48 35
Ø6.5 Ø4.3 SOCS 65 43
SimpleLine ll Product Catalog 11

Healing Abutment
Unit:mm, Scale 1: 1.5 / mm

Ø 5.2­­­­­­­­

SOHAB4820 and SOFX483810R

Healing Abutment | Single use only Ø5.2


Ø5.2

Application H Art. No. 4.0


2.0
2.0 SOHAB 48 20
Ø4.8
4.0 SOHAB 48 40
2.0 SOHAB 65 20
Ø6.5
4.0 SOHAB 65 40 Ø6.8
Ø6.8

2.0 4.0
12 SimpleLine ll Product Catalog

Prosthetic Procedure 1
Impression Technique and Restoration Selection

Solid / Dual / SCA Abutment

Abutment Level Impression


Closed Tray Technique

Solid Abutment Dual Abutment SCA Abutment


Ø4.8 / Ø6.5 Octa Ø4.8 / Ø6.5 Octa / Non-octa Ø4.8 / Ø6.5
Page 14 Page 14 Page 16

Impression Coping Impression Coping


Transfer (Snap on) Ø4.8 / Ø6.5 Transfer (Snap on) Ø5.5 / Ø6.5
Page 15 Page 17

Analog Analog
Ø4.8 / Ø6.5 Ø5.5 / Ø6.5

Page 15 Page 17

Burn-out Cylinder

Single Bridge Single Bridge


Non-rotational Rotational Non-rotational Rotational
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø5.5 / Ø6.5 Ø5.5 / Ø6.5

Page 15 Page 15 Page 17 Page 17

Modification

Cemented Restoration
SimpleLine ll Product Catalog 13

Solid Abutment
Unit:mm, Scale 1: 1.5 / mm

SOSAB4840N and SOFX483810R

Application Ø4.8 | One piece

5.5 7.0
H Art. No. 4.0
4.0 SOSAB 48 40 N
5.5 SOSAB 48 55 N
7.0 SOSAB 48 70 N

Application Ø6.5 | One piece

H Art. No.
5.5 7.0
4.0 SOSAB 65 40 N 4.0

5.5 SOSAB 65 55 N
7.0 SOSAB 65 70 N
14 SimpleLine ll Product Catalog

Dual Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

SODAB4855O and SOFX483810R

Application Ø4.8 | Octa

H Art. No. 5.5 7.0


4.0
4.0 SODAB 48 40 O
5.5 SODAB 48 55 O
7.0 SODAB 48 70 O Octa Octa Octa

Application Ø6.5 | Octa

H Art. No. 7.0


4.0 5.5
4.0 SODAB 65 40 O
5.5 SODAB 65 55 O
7.0 SODAB 65 70 O Octa Octa Octa

Abutment Screw

6.5
Art. No. SOAAS 20 23
SimpleLine ll Product Catalog 15

Abutment Level Impression Components


Unit:mm, Scale 1: 1.5 / mm

Comfort Cap | Solid / Dual Abutment

Application H Art. No.


7.5 9.0
6.0 SODCC 48 40 6.0
Ø4.8 7.5 SODCC 48 55
9.0 SODCC 48 70
6.0 SODCC 65 40
Ø6.5 7.5 SODCC 65 55 7.5 9.0
6.0
9.0 SODCC 65 70

Impression Coping | Solid / Dual Abutment

Application Diameter Art. No.


10.8 10.8
Ø4.8 Ø4.8 SODIC 48
Ø6.5 Ø6.5 SODIC 65

7.0
Analog | Solid / Dual Abutment 4.0 5.5

Application H Art. No.


4.0 SOCAN 48 40 P
Ø4.8 5.5 SOCAN 48 55 P
7.0 SOCAN 48 70 P
4.0 SOCAN 65 40 P
7.0
4.0 5.5
Ø6.5 5.5 SOCAN 65 55 P
7.0 SOCAN 65 70 P

Burn-out Cylinder | Solid / Dual Abutment

Application Type Art. No. 12.8 12.8


Single SODBC 48 S
Ø4.8
Bridge SODBC 48 B
Single SODBC 65 S
Ø6.5
Bridge SODBC 65 B
12.8 12.8
16 SimpleLine ll Product Catalog

SCA Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

SOCAB4808O and SOFX483810R

Application Ø4.8

G/H Type Art. No.


5.5 5.5
Octa SOCAB 48 08 O G/H 0.8
0.8
Non-octa SOCAB 48 08 N
Octa Non-octa
Octa SOCAB 48 18 O
1.8
Non-octa SOCAB 48 18 N
5.5 5.5
G/H 1.8

Octa Non-octa

Application Ø6.5

G/H Type Art. No.


5.5 5.5
Octa SOCAB 65 08 O G/H 0.8
0.8
Non-octa SOCAB 65 08 N
Octa Non-octa
Octa SOCAB 65 18 O
1.8
Non-octa SOCAB 65 18 N
5.5 5.5
G/H 1.8

Octa Non-octa
SimpleLine ll Product Catalog 17

Abutment Level Impression Components


Unit:mm, Scale 1: 1.5 / mm

Comfort Cap | SCA Abutment

Application Diameter Art. No.


6.8 6.8
Ø4.8 Ø5.5 CCC 55 C
Ø6.5 Ø6.5 CCC 65 C

Impression Coping | SCA Abutment

Application Diameter Art. No.


Ø4.8 Ø5.5 CIC 55 L 10.4 10.4

Ø6.5 Ø6.5 CIC 65 L

Analog | SCA Abutment


5.5 5.5
Application Diameter Art. No.
Ø4.8 Ø5.5 CAN 55 LL
Ø6.5 Ø6.5 CAN 65 LL

Burn-out Cylinder | SCA Abutment

Application Type Art. No.


Single CBC 55 SL 12.8 12.8
Ø4.8
Bridge CBC 55 BL
Single CBC 65 SL
Ø6.5
Bridge CBC 65 BL

12.8 12.8
18 SimpleLine ll Product Catalog

Restorative Kit

Solid & Dual Abutment


Lab Components
Art. No
Comfort Cap Impression Coping Analog Burn-out Cylinder
XSSODAB 48 40 SODCC 48 40 SOCAN 48 40 P
XSSODAB 48 55 SODCC 48 55 SODIC 48 SOCAN 48 55 P SODBC 48 S SODBC 48 B
XSSODAB 48 70 SODCC 48 70 SOCAN 48 70 P
XSSODAB 65 40 SODCC 65 40 SOCAN 65 40 P
XSSODAB 65 55 SODCC 65 55 SODIC 65 SOCAN 65 55 P SODBC 65 S SODBC 65 B
XSSODAB 65 70 SODCC 65 70 SOCAN 65 70 P

SCA Abutment
Lab Components
Art. No
Comfort Cap Impression Coping Analog Burn-out Cylinder
XSSOCAB 48 S CCC 55 CS CAN 55 SL
CIC 55 L CBC 55 SL CBC 55 BL
XSSOCAB 48 CCC 55 C CAN 55 LL
XSSOCAB 65 S CCC 65 CS CAN 65 SL
CIC 65 L CBC 65 SL CBC 65 BL
XSSOCAB 65 CCC 65 C CAN 65 LL
SimpleLine ll Product Catalog 19

Prosthetic Procedure 2
Impression Technique and Restoration Selection

Dual / SCA / Dual Milling / Angled / Direct-Casting /


Metal-Casting / Temporary Abutment

Fixture Level Impression

Octa Non-octa
Octa Non-octa

Impression Coping / Pick-up Impression Coping / Transfer


Open tray technique (Complicated case) Closed tray technique (Simple case)
Ø4.8 / Ø6.5 Ø4.8 /Ø6.5

Page 20 Page 20

Analog
Ø4.8 / Ø6.5

Page 22

Dual SCA Dual Milling Angled Direct-Casting Metal-Casting Temporary


Abutment Abutment Abutment Abutment Abutment Abutment Abutment
Octa Octa / Non-octa Octa Octa Octa / Non-octa Octa / Non-octa Octa / Non-octa
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 / Ø7.5 15º / 25º Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ti / Plastic
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Page 14 Page 16 Page 21 Page 21 Page 21 Page 21 Page 21

Modification Modification

Cemented Restoration Screw-Retained Restoration


20 SimpleLine ll Product Catalog

Fixture Level Impression Components


Unit:mm, Scale 1: 1.5 / mm

Impression Coping Pick-up

Application Type Art. No. Ø5.2 Ø5.2

Octa SODPU 48 52 O
Ø4.8
Non-Octa SODPU 48 52 N
Octa SODPU 65 68 O
Ø6.5
Non-Octa SODPU 65 68 N Octa Non-octa

Ø6.8 Ø6.8

Octa Non-octa

Impression Coping Transfer

Ø5.2 Ø5.2
Application Type Art. No.
Octa SODTF 48 52 O
Ø4.8
Non-Octa SODTF 48 52 N
Octa SODTF 65 68 O
Ø6.5 Octa Non-octa
Non-Octa SODTF 65 68 N

Ø6.8 Ø6.8

Octa Non-octa

Impression Coping Screw

Type Art. No.


19.5
Pick-up SODPS 11
13.5
Transfer SODTS 11
SimpleLine ll Product Catalog 21

Dual Milling Abutment


• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

Ø 5.5

SOMAB4830OG and SOFX483810R

Ø5.5
Application Ø4.8 | Octa

Type Art. No. 10.0


Octa SOMAB 48 30 OG

Octa

Application Ø6.5 | Octa Ø6.5 Ø7.5

Type Art. No.


Octa SOMAB 65 30 OG 3.0 3.0
Octa SOMAB 75 30 OG
Octa Octa
22 SimpleLine ll Product Catalog

Angled Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

15˚

SOAAB4815Oand SOFX483810R

Diameter Ø4.8 | Octa

Angled Art. No. 15˚ 25˚

15˚ SOAAB 48 15 O
25˚ SOAAB 48 25 O
Octa Octa

Diameter Ø6.5 | Octa

Angled Art. No. 15˚ 25˚

15˚ SOAAB 65 15 O
25˚ SOAAB 65 25 O
Octa Octa
SimpleLine ll Product Catalog 23

Direct Casting Abutment


• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Ø 5.2

SOCS4835 and SOFX483810R

Diameter Ø4.8 | Gold Ø5.2 Ø5.2

Type Art. No. 8.7


Octa SORAB 48 52 O
Non-octa SORAB 48 52 N 3.3

Octa Non-octa

Diameter Ø6.5 | Gold Ø6.8 Ø6.8

Type Art. No. 8.7


Octa SORAB 65 68 O
Non-octa SORAB 65 68 N 3.3

Octa Non-octa
24 SimpleLine ll Product Catalog

Metal-Casting Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

SORAB4852CO and SOFX483810R

Diameter Ø4.8 | Co-Cr Ø5.2 Ø5.2

Type Art. No. 8.7


Octa SORAB 48 52 CO
Non-octa SORAB 48 52 CN 3.3

Octa Non-octa

Diameter Ø6.5 | Co-Cr Ø6.8 Ø6.8

Type Art. No. 8.7


Octa SORAB 65 68 CO
3.3
Non-octa SORAB 65 68 CN

Octa Non-octa
SimpleLine ll Product Catalog 25

Temporary Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

SOTAB4852TOG and SOFX483810R SOTAB4852PO and SOFX483810R

Temporary Abutment - Ti
Ø5.2 Ø5.2 Ø6.8 Ø6.8
Application Type Art. No.
Octa SOTAB 48 52 TOG
Ø4.8 10.0 10.0 10.0 10.0
Non-octa SOTAB 48 52 TNG
Octa SOTAB 65 68 TOG
Ø6.5
Non-octa SOTAB 65 68 TNG Octa Non-octa Octa Non-octa

Temporary Abutment - Plastic

Ø5.2 Ø5.2 Ø6.8 Ø6.8


Application Type Art. No.
Octa SOTAB 48 52 PO
Ø4.8
Non-octa SOTAB 48 52 PN 10.0 10.0 10.0 10.0

Octa SOTAB 65 68 PO
Ø6.5
Non-octa SOTAB 65 68 PN
Octa Non-octa Octa Non-octa

Fixture Analog
Ø4.8 Ø6.5

Application Art. No.


Ø4.8 SODAN 48
12.7 12.9
Ø6.5 SODAN 65
Prosthetic Procedure 3
Impression Technique and Restoration Selection

Screw Abutment

Abutment Level Impression

Screw Abutment
Ø4.8 / Ø6.5

Page 24

Closed Open
Tray Technique Tray Technique

Impression Coping Transfer Impression Coping Pick-up


Hex / Non-hex Ø4.8 / Ø6.5 Hex / Non-hex Ø4.8 / Ø6.5
Page 25 Page 25

Analog
Ø4.8 / Ø6.5

Page 26

Burn-out Cylinder Gold Cylinder Metal Cylinder Titanium Cylinder


Ø4.8 /Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Page 27 Page 27 Page 27 Page 26

Bridge Single Bridge Single Bridge Single Bridge Single


(Non-hex) (Hex) (Non-hex) (Hex) (Non-hex) (Hex) (Non-hex) (Hex)

Polishing Protector
Ø4.8 / Ø6.5 Temporary Restoration
Page 26

Ti-Retaining Screw
Page 26

Screw-Retained Restoration
SimpleLine ll Product Catalog 27

Screw Abutment
Unit:mm, Scale 1: 1.5 / mm

r
de
ol
yH
er
liv
De

SOSAB4816 and NFX3609S

Screw Abutment
Ø3.6 Ø4.3
Application Art. No.
2.0 2.0
Ø4.8 SOSAB 48 16 2.4 2.4
Ø6.5 SOSAB 65 16
Hex Hex
28 SimpleLine ll Product Catalog

Screw Abutment Impression Components


Unit:mm, Scale 1: 1.5 / mm

Comfort Cap | Plastic

Application Art. No.


3.8 3.8
Ø4.8 SOSCC 48 35
Ø6.5 SOSCC 65 35

Comfort Cap | Metal

Application Art. No.


Ø4.8 SOSCC 48 T 5.5 5.5
Ø6.5 SOSCC 65 T

Impression Coping Pick-up

Application Type Art. No. Ø4.8 Ø4.8 Ø6.5 Ø6.5


Hex SOSPU 48 16 H
Ø4.8
Non-Hex SOSPU 48 16 N
Hex SOSPU 65 16 H
Ø6.5 Hex Non-hex Hex Non-hex
Non-Hex SOSPU 65 16 N

Impression Coping Transfer

Application Type Art. No.


Hex SOSTF 48 16 H Ø4.8 Ø4.8 Ø6.5 Ø6.5
Ø4.8
Non-Hex SOSTF 48 16 N
Hex SOSTF 65 16 H
Ø6.5
Non-Hex SOSTF 65 16 N Hex Non-hex Hex Non-hex
SimpleLine ll Product Catalog 29

Screw Abutment Impression Components


Unit:mm, Scale 1: 1.5 / mm

Impression Coping Screw

Type Art. No.


Pick-up SOSPS 09 16
14.0
Transfer SOSTS 09 16 8.4

Analog Ø4.8 Ø6.5

Application Art. No.


Ø4.8 SOSAN 48 16 14.8
14.8
Ø6.5 SOSAN 65 16

Polishing Protector

Application Art. No. Ø4.8 Ø6.5

Ø4.8 SOSPP 48 16
Ø6.5 SOSPP 65 16

Ø2.0
Ti-Retaining Screw
4.8
Art. No. SOSRS 16 T
Ø1.6
30 SimpleLine ll Product Catalog

Screw Abutment Impression Components


Unit:mm, Scale 1: 1.5 / mm

Ti-Cylinder
Application Type Art. No.
Hex SOSTC 48 16 HG 8.3 8.3
Ø4.8
Non-hex SOSTC 48 16 NG
3.7 3.7
Hex SOSTC 65 16 HG
Ø6.5 Hex Non-hex
Non-hex SOSTC 65 16 NG

8.3 8.3

3.7 3.7

Hex Non-hex

Gold Cylinder
Application Type Art. No.
Hex SOSGC 48 16 H 12.0 12.0
Ø4.8
Non-hex SOSGC 48 16 N
Hex SOSGC 65 16 H
Ø6.5 Hex Non-hex
Non-hex SOSGC 65 16 N

12.0 12.0

Hex Non-hex
SimpleLine ll Product Catalog 31

Screw Abutment Impression Components


Unit:mm, Scale 1: 1.5 / mm

Metal Cylinder - Co-Cr


Application Type Art. No.
Hex SOSGC 48 16 CH 12.0 12.0
Ø4.8
Non-hex SOSGC 48 16 CN
Hex SOSGC 65 16 CH
Ø6.5 Hex Non-hex
Non-hex SOSGC 65 16 CN

12.0 12.0

Hex Non-hex

Burn-Out Cylinder
Application Type Art. No.
Hex SOSBC 48 16 H
12.0 12.0
Ø4.8
Non-hex SOSBC 48 16 N
Hex SOSBC 65 16 H
Ø6.5 Hex Non-hex
Non-hex SOSBC 65 16 N

12.0 12.0

Hex Non-hex
Prosthetic Procedure 4
Impression Technique and Restoration Type

Overdenture Procedure

Positoner / Mini Ball / Magnetic Attachment

Positioner Mini Ball Abutment Implant Keeper


Ø4.8 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Page 29 Page 30 Page 31

Abutment Level Impression

Positioner Impression Coping Mini Ball Impression Coping


Page 29 Page 30

Positioner Analog Mini Ball Analog


Page 29 Page 30

Positioner Block Out Spacer Socket Spacer


Page 29 Page 30

Magnetic Assay
Page 31

Positioner Metal Socket Mini Denture Socket and O-ring


/ Plastic Socket Page 30
Page 29

Positioner Attachment Mini Ball and Socket Attachment Magnetic Attachment


for Overdenture for Overdenture for Overdenture
SimpleLine ll Product Catalog 33

Positioner Attachment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

FSMHS and SOPAB4810 and SOFX483810R

Positioner Abutment
Application G/H Art. No.
0 SOPAB 48 00
Ø4.8
1.0 SOPAB 48 10 1.0 1.0

0 SOPAB 65 00
Ø6.5
1.0 SOPAB 65 10

Positioner Impression Coping Ø4.5

4.5
PIC

Positioner Analog
12.4

PAN

Positioner Socket Set


FSMHS(Tilting Type ±10°)
Art. No.
FSMHSN(Non Tilting Type ±5°)
Metal Socket Plastic Socket Block Out spacer
34 SimpleLine ll Product Catalog

Positioner Attachment
Unit:mm, Scale 1: 1.5 / mm

Positioner Metal Socket


Ø5.2

Art. No. FSMH 2.3

­Positioner Plastic Socket


Application Art. No.
MSHP (Blue)
Tilting Type MSMP (Orange)
Retention Force 100gf 300gf 500gf 1,000gf
±10° MSLP (Ivory)
MSOP (White)

MSHPN (Blue)
Non Tilting Type MSMPN (Orange)
MSLPN (Ivory) Retention Force 100gf 300gf 500gf 1,000gf
±5°
MSOP (White)

Positioner Block Out Spacer Ø6.5


0.5
Art. No. PBOS

Positioner Core Tool


Art. No. XPCT
SimpleLine ll Product Catalog 35

Mini Ball Attachment


• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

BPF3 and SOBAB4800 and SOFX483810R

Mini Ball Abutment


Ø3.5 Ø4.3

Application Art. No. Ø1.8 Ø1.8

Ø4.8 SOBAB 48 00
Ø6.5 SOBAB 65 00

Ø3.8
Mini Ball Impression Coping
7.5
Art. No. ICA

Mini Ball Analog

Art. No. BANL

Socket Spacer
Art. No. BIC3L 4.3

Female Socket Ø4.05 Ø4.85


2.9 3.3
BPF3 (300~500gf)
Art. No. (BFS3) (BNO1) (BFS2) (BNO2)
BPF2 (500~700gf)
(300~500gf) (500~700gf)
36 SimpleLine ll Product Catalog

Magnetic Attachment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm

BPF3 and SOBAB4800 and SOFX483810R

Magnetic Assay Ø4.5


2.5 2.0 Retention Force 350gf
Application Art. No.
Ø4.8 MGT 45 20 D
Ø6.5 MGT 55 20 D Ø5.5
2.5 2.0 Retention Force 700gf

Implant Keeper
Ø5.0 Ø5.0
Application G/H Art. No.
2.0 SOMKP 48 20 D
2.0
Ø4.8 4.0
4.0 SOMKP 48 40 D
2.0 SOMKP 65 20 D
Ø6.5
4.0 SOMKP 65 40 D

Ø6.5 Ø6.5

2.0 4.0
SimpleLine ll Product Catalog 37

Surgical Kit
Unit:mm, Scale 1: 1.5 / mm

SimpleLine II Surgical Kit SOXIK

Kit includes

XLD 22 35 XLD 22 35 XFD 34 35 XFD 38 35 XFD 43 35 XFD 48 35

XLD 26 35 XLD 26 35 SOXTD 34 33 SOXTD 38 33 SOXTD 43 33 SOXTD 48 33

XPP 1622 48 XPP 1622 48 XPP 1622 48 XHD 25 H SOXHD 27 H XTS 40 XPP 1622 48

XPP 1622 48 XPP 1622 48 XPP 1622 48 XHD 26 T SOXHD 27 W XDE


38 SimpleLine ll Product Catalog

Drill
Unit: mm, Scale 1 : 1 / mm

Guide Drill (First, Second) | Stopper


Diameter L Art. No. Ø2.2 Ø1.7
Ø2.2 35 XLD 22 35
35
Ø2.6 35 XLD 26 35
Ø2.6 Ø2.35
Ø2.2 29 XLD 22 29
Ø2.6 29 XLD 26 29 35

Ø3.85

Ø4.4

29

Final Drill
Ø2.85
Diameter L Art. No.
Ø2.85 35 XFD 34 35 Ø3.3
Ø3.3 35 XFD 38 35
35
Ø3.85 33 XFD 43 33
Ø4.4 33 XFD 48 33 Ø3.85

Ø2.85 29 XFD 34 29
Ø4.4
Ø3.3 29 XFD 38 29
Ø3.85 29 XFD 43 29 33
Ø4.4 29 XFD 48 29
Ø2.85

Ø3.3

Ø3.85

Ø4.4

29

Round Bur

Diameter L Art. No. Ø2.0


Ø2.0 33 XRB 20 33
Ø3.0
Ø3.0 33 XRB 30 33
33
SimpleLine ll Product Catalog 39

Instrument
Unit: mm, Scale 1 : 1 / mm

Tap Drill Adapter


Art. No. XRA3917
17

Adapter
Type L Art. No.
21
21 SOXHD 21 H
Hand-piece 24 SOXHD 24 H
24
27 SOXHD 27 H
21 SOXHD 21 W 27
Ratchet 24 SOXHD 24 W
27 SOXHD 27 W

21

24

27

Mount Adapter
Type L Art. No.
Hand-piece 19 SOXMA 19 19

Ratchet 19 SOXRA 19

19

Hex Driver | Hex 1.28 mm


Type L Art. No.
Hand-piece 25 XHD 25 H 25

Manual 26 XHD 26 T

26
40 SimpleLine ll Product Catalog

Instrument
Unit: mm, Scale 1 : 1 / mm

Path Pin
L Art. No.
18.3
18.3 SOXMFPAS
23.3 SOXMFPA
23.3

Parallel Pin
Ø4.8 Ø1.6
Diameter L Art. No.
21.5
Ø4.8 21.5 XPP1622 48
Ø6.5 21.5 XPP1622 65 Ø6.5 Ø1.6

21.5

Drill Extension
Art. No. XDE
26

Tissue Punch
Art. No. XTS 40

※Hole punched diameter : Ø4.0

Ratchet
Art. No. XRCA1
SimpleLine ll Product Catalog 41

Prosthetic Kit

B.WRENCH
ADAPTER

SimpleLine II Prosthetic Kit XIP


Kit includes

XHD 15 XHD 30 T SDA 25 R XMMA 1

XHD 25 W XMA 21 W IPST 21 W

XNTW
42 SimpleLine ll Product Catalog

Prosthetic and Laboratory Instrument


Unit: mm, Scale 1: 1 / mm

Hex Driver | Hex 1.28 mm


Hex 1.28
L Art. No.
13
13 XHD 13
15 XHD 15
21 XHD 21
15
28 XHD 28

21

28

Hex Driver | Hex 1.28 mm


25
Type L Art. No.
Torque Wrench 25 XHD 25 W
Manual 30 XHD 30 T
30

Adapter
Type L Art. No. 21

Hand-piece 21 XMAA 1
Torque Wrench 21 XHD 21 W
21
Mini Ball 21 IPST 21 W

21

Slot Driver
Art. No. SDA 25 R
25

Torque Wrench | Scale 1 : 0.7 / mm


Art. No. XNTW
SimpleLine ll Product Catalog 43

Prosthetic and Laboratory Instrument


Unit: mm, Scale 1: 1 / mm

Reamer Guide | Solid / Dual Abutment


Application Art. No. Ø4.8
Ø4.8 OISRG 48
Ø6.5 SOSRG 65
Ø6.5

Reamer Guide | SCA Abutment


Application Art. No. Ø4.8
Ø4.8 CRG 55 L
Ø6.5 CRG 65 L
Ø6.5

Reamer Guide | Screw Abutment


Application Art. No. Bridge
Bridge SOSRG BL
Single SOSRG SL Single

Reamer | Solid / Dual / Screw Abutmen


Application Art. No.
Ø4.8 OISRM
Ø6.5 SOSRM 65

Reamer | SCA Abutment


Art. No. CRM

Reamer Handle | Scale 1 : 0.5 / mm


Art. No. CRH
44 SimpleLine ll Product Catalog

SURGICAL MANUAL

Surgical Drill Sequence 45

Fixture Installation 46

Fixture Connection 46

Surgical Kit Maintenance 47

Warnings 48
SimpleLine ll Product Catalog 45

Surgical Drill Sequence

8 10 12 14 16

Final drill
First Second
guide guide
drill drill 3.4 3.8 4.3 4.8

Ø2.2 Ø2.6
Ø2.85 Ø3.3 Ø3.85 Ø4.4

Platform: Ø4.8
Body: Ø3.4

Platform: Ø4.8
Body: Ø3.8

Platform: Ø4.8 /Ø6.5


Body: Ø4.3

Platform: Ø6.5
Body: Ø4.8
46 SimpleLine ll Product Catalog

Fixture Installation
Platform: Ø6.5 / Body: Ø4.8 (800~1,200rpm / 30~45N·cm)

Final drill Final drill


Ø4.3 Ø4.8

Ø6.5

10mm

Ø4.8

Fixture Connection

Caution_ When opening the fixture package,


hold it upright to avoid falling out of
the fixture. Securely engage the
adapter with the fixture.

By hand-piece By ratchet
20rpm / 35N·cm
SimpleLine ll Product Catalog 47

Directions when Using the Hand-piece / Ratchet Adapter


Hand-piece Ratchet
adapter adapter

Connection

Hand-piece Ratchet The ratchet adapter and the fixture interal octa must be
adapter adapter firmly connected together.

Surgical Kit Maintenance


Sterilization and Instrument Care Procedures
• Please follow legal regulations, as well as hygienic guidelines to prevent contamination and infection.
• Please remember that you are responsible for the maintenance and sterilization of your medical / dental
products/devices. It is important to use and follow proper cleaning, disinfection and sterilization procedures.
• It is also important to follow the manufacture's recommendation on the usage of the drills..
Please keep a log as to the number of times the drills are used.
• Drills are used per implant placed not per patient. Bone density determines the longevity of the drills.
• Replace white and red o-rings on the adapters and the hex drivers, if worn and dried out.
• Drills should be considered for replacement after about 40 uses based on bone density.

01 A
 ll instruments, immediately after use, must be pre-soaked for a few minutes in a germicidal bath to loosen and
prevent debris from attaching to instruments. Do not soak over-night.
02 Scrub with a soft brush to remove any debris.
03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.
04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 gauze to prevent the drills from rubbing against each other.
05 Rinse thoroughly under warm water.
06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.
07 Dry completely and place back into kit.
08 Always check for damage or corrosion after rinsing and drying.
09 Seal the tray in a sterilization pouch.
10 Sterilize using a steam autoclave at 121°C / 250℉ for 30 minutes or refer to manufacture's recommendations.
11 Store in a dry area at room temperature.

Maintenance Period for Surgical Drills


All surgical drills should be replaced after approximately 40 uses based on bone density

Guide Drill (First, Second) Final Drill


800~1200rpm, 30~45N·cm with Irrigation 800~1200rpm, 30~45N·cm with Irrigation
48 SimpleLine ll Product Catalog

Warnings

Warnings
Dental implant surgery and restoration involve complex dental procedures. Appropriate and adequate
training in proper technique is strongly recommended prior to use.
• Improper medical examination and / or treatment plan can result in implant failure and / or loss of supportive bone.
• Improper initial stability and / or excessive occlusal forces during healing period may lead to osseointergration failure.
• Excessive insertion torque may lead to a mechanical failure or a implant biologic failure due to bone compression and
necrosis.
• When forces or loads are greater than its design, implant or abutment fracture could occur. Therefore clinicians
should make careful decisions in regards to clinical treatment planning to minimize the risk of fracture. Appropriate
implant quantity, occlusal interface and a nightguard are essential. Potential excessive loading conditions may include
the following:

01 Inadequate number of implants are placed.


02 Implant width and / or length are inappropriate for a treatment site.
03 Prosthesis which has excessive cantilever length due to inadequate biomechanical design.
04 Continuous occlusal force may be generated by incomplete connection between implant and abutment and /
or abutment screw loosening.
05 Direct casting abutment angles are greater than 30°w from the vertical axis of the implant.
Angled abutment is excessively milled.
06 Occlusal interferences causing excessive lateral forces.
07 Patient parafunctions such as bruxism.
08 Inadequate dental laboratory casting procedures.
09 Improper prosthesis fit.
10 Trauma from patient habits or accidents.
11 Excessive marginal bone loss caused by inadequate bone width and / or advanced periimplantitis.
SimpleLine ll Product Catalog 49

PROSTHESIS MANUAL
Types of Abutment 50

Prosthetic Procedure 1 51
Abutment Level- Solid / Dual Abutment 52
Abutment Level- SCA Abutment 55

Prosthetic Procedure 2 58
Fixture Level [Pick-up Type]- Dual Abutment 59
Fixture Level [Transfer Type]- Dual Abutment 62
Fixture Level- SCA Abutment 65
Fixture Level- Dual Milling Abutment 67
Fixture Level- Angled Abutment 69
Fixture Level- Direct Casting Abutment 71

Prosthetic Procedure 3 73
Abutment Level- Screw Abutment 74

Cementation Repair Method (SCRP) 74

Prosthetic Procedure 4 79
Positioner 80
Ball Attachment 82
Magnetic Attachment 84
50 SimpleLine ll Product Catalog

Types of Abutment

One-Piece Two-Pieces

Octa Octa Non-Octa

Solid Abutment Dual Abutment SCA Abutment

Octa 15° 25° Octa Non-Octa

Screw Abutment Dual Milling Abutment Angled Abutment Direct-Casting Abutment

Ti Plastic

Octa Non-Octa Octa Non-Octa Octa Non-Octa

Cylinder Metal-Casting Abutment Temporary Abutment

Abutment Level Fixture Level

· Dual Abutment
Positioner Ball Magnetic
· Solid Abutment Abutment level
· SCA Abutment Overdenture

· Dual Abutment
· SCA Abutment
· Dual Milling Abutment
· Angled Abutment (15°/25°) Fixture level
· Direct-Casting Abutment
· Metal-Casting Abutment
· Temporary Abutment

· Screw Abutment Screw retained (Abutment level)

· Positioner
· Ball For denture use
· Magnetic
SimpleLine ll Product Catalog 51

Prosthetic Procedure 1
Impression Technique and Restoration Selection

Solid / Dual / SCA Abutment

Abutment Level Impression


Closed Tray Technique

Solid Abutment Dual Abutment SCA Abutment


Ø4.8 /Ø6.5 Octa Ø4.8 / Ø6.5 Octa / Non-octa Ø4.8 / Ø6.5

Impression Coping Impression Coping


Transfer (Snap on) Ø4.8 / Ø6.5 Transfer (Snap on) Ø5.5 / Ø6.5

Analog Analog
Ø4.8 / Ø6.5 Ø5.5 / Ø6.5

Burn-out Cylinder

Single Bridge Single Bridge


Non-rotational Rotational Non-rotational Rotational
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø5.5 / Ø6.5 Ø5.5 / Ø6.5

Modification

Cemented Restoration
52 SimpleLine ll Product Catalog

Abutment Level- Solid / Dual Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment Solid Abutment or Abutment Level Provisional Comfort Cap


Dual Abutment Impression Restoration with or
without Comfort Cap

Chairside

Fixture installation. Choose solid abutment Tighten the abutment


or dual abutment. with 25~30N·cm and
retighten it after 15 minutes.

Affix the impression coping on Apply the impression material. Take the impression.
the abutment.

Image of the set final impression Place comfort cap over the abutment.
with impression coping­­­.
SimpleLine ll Product Catalog 53

Abutment Level- Solid / Dual Abutment


[Multiple Units]

Laboratory Procedure
Gold
Crown

Porcelain
Crown

Lab Analog Connection Cylinder Crown Wax-up Final Restoration


Cementation Type

Lab Side

Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
embedded impression coping. locked into the impression coping
(line up the flat side of analog to the flat
side of the coping).

Create the master model. Snap on the burn-out cylinders Cut the cylinder after measuring proper
securely onto the analogs. height based on the proximity of the
opposing teeth.

Prepare for wax-up by affixing the Completion of wax-up. Produce the metal framework.
plastic bar.
54 SimpleLine ll Product Catalog

Abutment Level- Solid / Dual Abutment


[Multiple Units]

Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.

Metal Framework after the removal of Metal framework. Porcelain build-up.


the "Lip".

[Only Dual Abutment]


SCRP : Once an access hole has been created, it could be converted to a
SCRP (Screw & Cement Retained Prosthesis).

Final prosthesis. Create an access hole when the Image of the extended margin around
burn-out cylinder is used for the wax-up. the metal framework.

Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.

Metal framework after the removal of Metal framework. Final prosthesis.


the "Lip".
SimpleLine ll Product Catalog 55

Abutment Level- SCA Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment SCA Abutment Abutment Level Provisional Comfort Cap


Impression Restoration with or
without Comfort Cap

Chairside

Fixture installation. Choose SCA abutment Tighten the abutment


(Octa / Non-octa). with 25~30N·cm and
retighten it after 15 minutes.

Affix the impression coping on Apply the impression material. Take the impression.
the abutment.

Image of the set final impression Place comfort cap over the abutment.
with impression coping.
56 SimpleLine ll Product Catalog

Abutment Level- SCA Abutment


[Multiple Units]

Laboratory Procedure
Gold
Crown

Porcelain
Crown

Lab Analog Connection Cylinder Crown Wax-up Final Restoration


Cementation Type

Lab Side

Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
embedded impression coping. locked into the impression coping (line
up the flat side of analog to the flat
side of the coping).

Create the master model. Snap on the burn-out cylinders Cut the cylinder after measuring proper
securely onto the analogs. height based on the proximity of the
opposing teeth.

Prepare for wax-up by affixing the Completion of wax-up. Produce the metal framework.
plastic bar.
SimpleLine ll Product Catalog 57

Abutment Level- SCA Abutment


[Multiple Units]

Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.

Metal Framework after the removal of Metal framework. Porcelain build-up.


the "Lip".

SCRP : Once an access hole has been created, it could be converted to a


SCRP (Screw & Cemented Retained Prosthesis).

Final prosthesis. Create an access hole when the Image of the extended margin around
burn-out cylinder is used for the wax-up. the metal framework.

Shave off of the extended margin by Metal framework and reamer. Use the reamer to eliminate the "Lip"
using the rubber wheel. created by the "snap-on" mechanism.

Metal framework after the removal of Metal framework. Final prosthesis.


the "Lip".
58 SimpleLine ll Product Catalog

Prosthetic Procedure 2
Impression Technique and Restoration Selection

Dual / SCA / Dual Milling / Angled / Direct-Casting /


Metal-Casting / Temporary Abutment

Fixture Level Impression

Octa Non-octa
Octa Non-octa

Impression Coping / Transfer


Impression Coping / Pick-up
Closed tray technique (Simple case)
Open tray technique (Complicated case)
Ø4.8 / Ø6.5
Ø4.8 / Ø6.5

Analog
Ø4.8 / Ø6.5

Dual SCA Dual Milling Angled Direct-Casting Metal-Casting Temporary


Abutment Abutment Abutment Abutment Abutment Abutment Abutment
Octa Octa / Non-octa Octa Octa Octa / Non-octa Octa / Non-octa Octa / Non-octa
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 / Ø7.5 15° / 25° Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ti / Plastic
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Modification Modification

Cemented Restoration Screw-Retained Restoration


SimpleLine ll Product Catalog 59

Fixture Level [Pick-up Type]- Dual Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment Impression Coping Fixture Level Impression


Pick-up Type Open Tray

Chairside

Pick-up type impression coping


(Octa).

Apply adhesive on the open tray. Apply the impression material.


(Individual tray)

Take the impression. Remove the screw before removing Image of the set final impression
the impression tray. with impression coping.
60 SimpleLine ll Product Catalog

Fixture Level [Pick-up Type]- Dual Abutment


[Multiple Units]

Laboratory Procedure
Gold
Crown

Porcelain
Crown

Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
Dual Abutment cutting for Cementation Type
height adjustment

Lab Side

Connect analogs with the Soft tissue modeling. Create the master model.
embedded impression coping.

Assemble the dual abutment. If deemed necessary, abutment milling Fabricate the positioning jig
is possible.

Fabricate the cap with Completion of wax-up. Metal framework.


pattern resin.
SimpleLine ll Product Catalog 61

Fixture Level [Pick-up Type]- Dual Abutment


[Multiple Units]

Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the intraoral occlusal adjustment.
and then tighten it with 25~30N·cm.
Re-tighten it after 15 minutes.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.

SCRP- Lab Side

Create an access hole for Completion of Wax-up. Metal framework.


pick-up coping screw.

SCRP- Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the intraoral occlusal adjustment.
and tighten with to 25~30N·cm.
Re-tighten it after 15 minutes.

* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
62 SimpleLine ll Product Catalog

Fixture Level [Transfer Type]- Dual Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment Impression Coping Fixture Level Impression


Transfer Type Closed Tray

Chairside

Transfer type impression coping Connect the impression coping for


(Octa). fixture level impression.

Apply the impression material. Take the impression. Image of the set final impression
with impression coping.
SimpleLine ll Product Catalog 63

Fixture Level [Transfer Type]- Dual Abutment


[Multiple Units]

Laboratory Procedure
Gold
Crown

Porcelain
Crown

Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
Dual Abutment cutting for Cementation Type
height adjustment

Lab Side

Impression coping and analog Make sure the analogs are securely Soft tissue modeling.
connection. And insert impression seated in the impression coping (line
coping into the impression.­­­ up the flat side of analog to the flat
side of the coping).

Create the master model. Examine the soft tissue condition after Assemble the dual abutment.
the retrieval of the impression coping.

If deemed necessary, abutment milling Fabricate the positioning jig. Fabricate the cap with pattern resin.
is possible.
64 SimpleLine ll Product Catalog

Fixture Level [Transfer Type]- Dual Abutment


[Multiple Units]

Completion of wax-up. Metal framework. Final prosthesis build-up on the


framework with porcelain.

Chairside

Use the positioning jig to transfer Cement the final prosthesis and make
the abutment from the model to the occlusal adjustment. Place wax into
intraoral and tighten it with 25~30N·cm. the opening of the abutment to protect
Re-tighten after 15 minutes. the screw head prior to the composite
sealing.

SCRP- Lab Side

Create an access hole for the pick-up Completion of Wax-up. Metal framework.
coping screw.

SCRP- Chairside

Final prosthesis. Use positioning jig to transfer Cement the final prosthesis and make
abutment from the model to the in- occlusal adjustment. Place wax into
traoral and tighten it with 25~30N?cm. the opening of the abutment to protect
Re-tighten after 15 minutes. the screw head prior to the composite
sealing.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 65

Fixture Level- SCA Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment Fixture Level Impression Fixture Level Impression


Pick-up Type Transfer Type
Open Tray Closed Tray

Laboratory Procedure
Gold
Crown

Porcelain
Crown

Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
SCA Abutment cutting for Cementation Type
height adjustment

Lab Side

Connect analogs with the Soft tissue modeling. Create the master model.
embedded impression coping.
66 SimpleLine ll Product Catalog

Fixture Level- SCA Abutment [Multiple Units]

Assemble the SCA abutment. If deemed necessary, abutment milling Fabricate the positioning jig
is possible.

Fabricate the cap with Completion of wax-up. Metal framework.


pattern resin
Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the in- clusal adjustment. Place wax into the open-
traoral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it after 15 minutes. head prior to the composite sealing.

* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
SCRP- Lab Side case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.

Create an access hole for Completion of wax-up. Metal framework.


pick-up coping screw
SCRP-Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the in- occlusal adjustment. Place wax into the
traoral and tighten it with 25~30N·cm. opening of the abutment to protect the
Re-tighten it after 15 minutes. screw head prior to the composite sealing.

* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 67

Fixture Level- Dual Milling Abutment


[Single Unit]

Clinical Procedure

Healing Abutment Fixture Level Impression Fixture Level Impression


Pick-up Type Transfer Type
Open Tray Closed Tray

Laboratory Procedure

Lab Analog Connection Dual Milling Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type

Lab Side

Connect analogs with the Soft tissue modeling. Create the master model.
set impression material.
68 SimpleLine ll Product Catalog

Fixture Level- Dual Milling Abutment


[Single Unit]

Assemble the dual milling abutment. Milled the abutment to an Fabricate the positioning jig
appropriate size.

Fabricate the cap with pattern resin. Completion of wax-up. Metal framework.

Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the in- clusal adjustment. Place wax into the open-
traoral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it aAfter 15 minutes. head prior to the composite sealing.

* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 69

Fixture Level- Angled Abutment


[Single Unit]

Clinical Procedure

Healing Abutment Fixture Level Impression Fixture Level Impression


Pick-up Type Transfer Type
Open Tray Closed Tray

Laboratory Procedure

Lab Analog Connection Angled Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type

Lab Side

Impression coping with analog Soft tissue formation and fabrication Unscrew and separate the impression
connections. of master model. from the model.
70 SimpleLine ll Product Catalog

Fixture Level- Angled Abutment


[Single Unit]

Create the master model. Assemble the angled abutment. Milled the abutment to an appropriate
size and fabricate the positioning jig.

Fabricate the cap with pattern resin. Completion of wax-up. Metal or zirconia framework.

Chairside

Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the occlusal adjustment. Place wax into the
intraoral and tighten it with 25~30N·cm. opening of the abutment to protect the
Re-tighten it after 15 minutes. screw head prior to the composite sealing.
SimpleLine ll Product Catalog 71

Fixture Level- Direct-Casting Abutment


[Single Unit]

Clinical Procedure

Healing Abutment Fixture Level Impression Fixture Level Impression


Pick-up Type Transfer Type
Open Tray Closed Tray

Laboratory Procedure

Lab Analog Connection Direct-Casting Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type

Lab Side

Impression coping with analog Soft tissue formation and fabrication Unscrew and separate the impression
connections. of master model. from the model.
72 SimpleLine ll Product Catalog

Fixture Level- Direct-Casting Abutment


[Single Unit]

Assemble the direct casting abutment. Completed customized abutment. Fabricate the positioning jig.

Fabrication of pattern resin cap Completion of wax-up. Metal or zirconia framework.

Chairside

---Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the int- clusal adjustment. Place wax into the open-
raral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it after 15 minutes. head prior to the composite sealing.

Fixture Level- Temporary Abutment


[Multiple Units]

<Using Ti Abutment> <Using Plastic Abutment>

Consider the opposing teeth before


Ti-Temporary Plastic seating the temporary abutment.
Abutment Temporary Trim off the abutment as needed and
Abutment complete the temporary abutment
prosthesis with direct resin.
SimpleLine ll Product Catalog 73

Prosthetic Procedure 3
Impression Technique and Restoration Selection

Screw Abutment

Abutment Level Impression

Screw Abutment
Ø4.8 / Ø6.5

Closed Open
Tray Technique Tray Technique

Impression Coping Transfer Impression Coping Pick-up


Hex / Non-hex Ø4.8 / Ø6.5 Hex / Non-hex Ø4.8 / Ø6.5

Analog
Ø4.8 / Ø6.5

Burn-out Gold Metal Titanium


Cylinder Cylinder Cylinder Cylinder
Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Bridge Single Bridge Single Bridge Single Bridge Single


(Non-hex) (Hex) (Non-hex) (Hex) (Non-hex) (Hex) (Non-hex) (Hex)

Polishing Protector
Ø4.8 / Ø6.5 Temporary Restoration

Ti-Retaining Screw

Screw-Retained Restoration
74 SimpleLine ll Product Catalog

Abutment Level- Screw Abutment


[Multiple Units]

Clinical Procedure

Healing Abutment Screw Abutment Impression Coping Abutment Level


Transfer Type Impression

Chairside

Screw abutment and delivery holder. Select and seat an appropriate screw Tighten it with 25~30N·cm.
abutment with delivery holder. Re-tighten it after 15 minutes
with screw abutment adapter.

Screw abutment transfer copings Connect the impression coping for Apply the impression material.
(abutment level). abutment level impression.

Take the impression. Image of the set final impression Place comfort cap over the screw
with impression coping. abutment.
SimpleLine ll Product Catalog 75

Abutment Level- Screw Abutment


[Multiple Units]

Laboratory Procedure

Lab Analog Connection Cylinder Connection Modification Crown Wax-up Final Restoration
Screw Retained

Lab Side

Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
set impression. seated in the impression coping (line
up the flat side of analog to the flat
side of the coping).

Create the master model. Remove the impression coping. Connect the screw abutment cylinder
and tighten it with Ti-retaining screw.

Trim cylinder after measuring proper Connect the plastic bar in the middle Completion of wax-up.
height based on the proximity of the of trimmed burn-out cylinders to help
opposing teeth.. support the wax pattern.
Wax pattern may experience
shrinkages.
76 SimpleLine ll Product Catalog

Abutment Level- Screw Abutment


[Multiple Units]

Gold framework. Use the reamer to remove the "Lip" in Completion of gold framework.
the interior of the metal framework.

Final prosthesis. Insert the final prosthesis and make


necessary occlusal adjustments.
Tighten it with ti-retaining screw
(10 N·cm).
SimpleLine ll Product Catalog 77

Cementation Repair Method (SCRP)


[Screw & Cement Retained Prosthesis]

In light of Implant Prosthesis:


• Screw type restoration simplifies prosthetic repair or insertion and removal of the prosthesis to any given situation.
• Cement type restoration tend to have a stable occlusion and may enhance the adaptability.
However the weak point is, it cannot be removed after permanent cementation.
• A SCA abutment can be cemented or screw retained.
• Solid abutments are cement retained and no occlusal hole is necessary.

Screw Loosening or Prosthesis Repair

In case of the following: In order to unscrew, create access Unscrew, and remove the prosthesis
screw loosening or hole on the occlusal surface with a bur. from the patient's mouth.
prosthesis repair

Both cemented prosthesis and Finish the repair and seat it inside Tighten the prosthesis with
abutments are removed. the patient's mouth. 25~30N·cm with a screw driver
* It is recommended that the abutment screw is
retightened after 15 minutes.

Place a small piece of cotton to Fill the remaining access space with Final prosthesis.
cover the head of the screw. a resin.
78 SimpleLine ll Product Catalog

Cementation Repair Method (SCRP)


[Screw & Cement Retained Prosthesis]

Separation of Prosthesis with Abutment due to Cement Loss

Remove the screw completely with Apply cement to the prosthesis. Place it back into the patient's mouth.
screw driver and remove prosthesis
* In case of screw abutment connection,
from the patient's mouth.
Ti-Retain screw has to be tightened with) 10N·cm.

Unscrew and remove the excessive Finish the repair and seat it inside Tighten the prosthesis with
cement. the patient's mouth. 25~30N·cm with a screw driver.

Augmenting Interproximal Volume to Repair Prosthesis Loosening

Adding volume to the interproximal Create access hole on the occlusal Unscrew and remove the cemented
surface to repair loosening. surface with a bur. prosthesis with abutment from the
patient's mouth.

Add resin to the prepared space Screw back in the prosthesis and
on the contact surface. perform light curing. Aftermath, polish
the contact surface.

Position the prosthesis in the mouth and


tighten the screw with 25~30N·cm.
Fill in the access hole.
SimpleLine ll Product Catalog 79

Prosthetic Procedure 4
Impression Technique and Restoration Type

Overdenture Procedure

Positoner / Mini Ball / Magnetic Attachment

Positioner Mini Ball Abutment Implant Keeper


Ø4.8 Ø4.8 / Ø6.5 Ø4.8 / Ø6.5

Abutment Level Impression

Positioner Impression Coping Mini Ball Impression Coping

Positioner Analog Mini Ball Analog

Positioner Block Out Spacer Socket Spacer

Magnetic Assay

Positioner Metal Socket Mini Denture Socket and O-ring


/ Plastic Socket

Positioner Attachment Mini Ball and Socket Attachment Magnetic Attachment


for Overdenture for Overdenture for Overdenture
80 SimpleLine ll Product Catalog

Positioner
Chairside

Connect the Positioner Abutment onto Affix the impression coping on the Take impression for the production of
the fixture. Positioner Abutment. the individual tray.

Produce the individual tray for After connecting the Positioner Take the final impression with the
denture impression. Abutment and the impression coping prepared individual tray.
together, apply the impression material.

After the impression material is set, Image of the set final impression
discard the individual tray. (with impression coping).

Lab side

Positioner Analog. Insert the Positioner Analog into the Create the master model.
embedded impression coping.

"Block out" procedure to achieve the Fabrication of the denture with


space required for the metal socket. conventional method
SimpleLine ll Product Catalog 81

Positioner
Case 1 Chairside

Secure spaces for the female sockets. Place the "block out spacer" on the Posi- Connect the metal socket onto the
tioner Abutment in the patient's mouth. Positioner Abutment.

Apply a small amount of resin into the Position the denture in the mouth and Remove the white plastic socket (100gf)
space created for the metal socket. wait until the resin is completely set. using the positioner tool and replace
with a regular plastic socket of a desired
retention force (300, 500 or 1000gf).

Remove the denture after the resin is Remove the block out spacer from Polish and the overdenture
fully set. Image of the denture the patien's mouth. is complete.
with the metal socket.

Case 2 Chairside

Create holes for the placement Place the "block out spacer" on the Connect the metal socket onto the
of the metal sockets. Positioner Abutment in the intraoral. Positioner Abutment.

Examine for interference Apply the resin into the holes and wait Remove the white plastic socket (100gf)
between the inner surface of the until it is completely set. using the positioner tool and replace
with a regular plastic socket of a desired
holes and the female sockets. retention force (300, 500 or 1000gf).

Apply additional resin around the Apply resin around the metal socket. Polish and the overdenture
metal socket where there is a short- is complete.
age of resin.
82 SimpleLine ll Product Catalog

Ball Attachment
Chairside

Connect the Ball Abutment with Affix the impression coping Take impression for the production of
the fixture. on the Ball Abutment. the individual tray.

Produce the individual tray for Apply the impression material. Take the final impression with the
denture impression. prepared individual tray.

After the impression material is set, Image of the set final impression
discard the individual tray. (with impression coping).

Lab side

Ball Analog. Insert the analogs into the embedded Create the master model.
impression coping.

Socket spacer. Fabrication of the denture


with conventional method.
SimpleLine ll Product Catalog 83

Ball Attachment
Case 1 Chairside

Secure spaces for the female sockets. Connect the female sockets to the Apply small amount of the resin
Ball Abutment in the intraoral. into the secured area.

Position the denture in the mouth and Female sockets are placed Polish and the overdenture
wait until the resin is completely set. in the denture. is complete.

Case 2 Chairside

Create holes for the placement Connect the female sockets to the Examine for interference between the
of the female sockets. Ball Abutment in the intraoral. inner surface of the holes and the
female sockets.

Apply the resin into the holes and wait Place the female sockets. Apply resin around the female sockets.
until it is completely set.

Polish and the overdenture


is complete.
84 SimpleLine ll Product Catalog

Magnetic Attachment
Chairside

Remove the Healing Abutment. Connect implant keeper with the fix- Implant keepers connected with
ture and tighten it with 25~30 N·cm. the fixtures.

Position the magnetic assay on the Secure spaces for the magnetic as- Examine for interference between inner
implant keeper. says. divets of the denture and the magnets.

Case 1

Apply resin on the divets of the Position the denture into the mouth Position the denture into the mouth
denture's inner surface. and wait until the resin is completely and wait for initial setting.
set.

Remove the denture and apply resin After the resin is completely set,
around the magnets. remove excess. Polish and the
overdenture is complete.
SimpleLine ll Product Catalog 85

Magnetic Attachment
Case 2

Create holes for the placement of Examine for interference between the Apply small amount of resin into the
the magnets. inner surface of the holes and hole.
the magnets.

Position the denture in the mouth and After initial setting, remove denture Add the resin around the magnets.
wait until the resin is completely set. from the mouth.

Polish and the overdenture is complete.


88 SimpleLine ll Product Catalog

Unit:mm, Scale 1: 1.5 / mm

SimpleLine II
Product/Manual Catalog

Specifications are subject to change without notice.


Some products listed in this catalog are not available in the market due to pending approval.­

HEAD OFFICE SL2PM-1611[Rev.1]


501 Gyeonggi R&DB Center, 105 Gwanggyo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea [443-270]
T +82-31-888-5431 F +82-31-888-5430
E-mail biz_mail@dentium.com / www.dentium.com

You might also like