Professional Documents
Culture Documents
Product/Manual Catalog
SimpleLine II
PRODUCT CATALOG
Introduction
S.L.A. Surface 04
SimpleLine II Characteristics 06
SimpleLine II Color Coding by Diameter 07
SimpleLine II Fixture 08
Surgical Components
Cover Screw & Healing Abutment 10
Prosthetic Procedure 1
Solid / Dual / SCA Abutment 12
Solid Abutment 13
Dual Abutment 14
Abutment Level Impression Components- Solid / Dual Abutment 15
SCA Abutment 16
Abutment Level Impression Components- SCA Abutment 17
Restorative Kit 18
Prosthetic Procedure 2
Dual / SCA / Dual Milling / Angled / Direct-Casting Abutment / Metal-Casting Abutment 19
Fixture Level Impression Components 20
Dual Milling / Angled / Direct-Casting / Metal-Casting Abutment 21
Temporary Abutment(Ti / Plastic) / Analog 24
Prosthetic Procedure 3
Screw Abutment 26
Screw Abutment 27
Screw Abutment Impression Components 28
Prosthetic Procedure 4
Overdenture Procedure - Positioner / Ball / Magnetic Attachment 32
Positoner 33
Mini Ball Attachment 35
Magnetic Attachment 36
Instruments
SimpleLine II Surgical Kit 37
Drill 38
Instrument 39
Prosthetic Kit 41
Prosthetic and Laboratory Instrument 42
Surgical Manual 44
Prosthetic Manual 49
4 SimpleLine ll Product Catalog
S.L.A. Surface
S.L.A. (Sandblasting with large grit and acid etching)
• Higher bone-to-implant contact.
• Faster bone formation on the surface.
In vivo test
SimpleLine ll Product Catalog 5
6 SimpleLine ll Product Catalog
SimpleLine II Characteristics
SCA Abutment
Ø2.0mm
4.8mm
Ø1.6mm
8 degree Morse Taper Octagon
Connection
0.4
SimpleLine ll Product Catalog 7
Cap Color
Fixture
SimpleLine II
(Mount Free)
A
Platform 4.8 4.8 4.8 6.5 6.5
Diameter
D
B
Body 3.4 3.8 4.3 4.3 4.8
Diameter
C
Bevel Height 0.55 0.55 0.55 0.75 0.75
D
Gingival 2.0 2.0 2.0 2.0 2.0
Height
8 SimpleLine ll Product Catalog
SimpleLine II Fixture
Unit: mm, Scale 1 : 1.5 / mm
Ø4.8
Platform Ø4.8 | Body Ø3.4 0.55 08 10 12
G/H 2.0
L Art. No.
08 SOFX 4834 08 R
L
10 SOFX 4834 10 R
12 SOFX 4834 12 R
Ø3.4
Ø4.8
Platform Ø4.8 | Body Ø3.8 08 10 12
0.55
G/H 2.0
L Art. No.
08 SOFX 4838 08 R
10 SOFX 4838 10 R L
12 SOFX 4838 12 R
Ø3.8
Ø4.8
Platform Ø4.8 | Body Ø4.3 08 10 12
0.55
G/H 2.0
L Art. No.
08 SOFX 4843 08 R
L
10 SOFX 4843 10 R
12 SOFX 4843 12 R
Ø4.3
SimpleLine ll Product Catalog 9
SimpleLine II Fixture
Ø6.5
Platform Ø6.5 | Body Ø4.3
0.75 08 10 12
L Art. No. G/H 2.0
08 SOFX 6543 08 R
L
10 SOFX 6543 10 R
12 SOFX 6543 12 R
Ø4.3
Ø6.5
Platform Ø6.5 | Body Ø4.8
0.75 08 10 12
L Art. No. G/H 2.0
08 SOFX 6548 08 R
L
10 SOFX 6548 10 R
12 SOFX 6548 12 R
Ø4.8
10 SimpleLine ll Product Catalog
Cover Screw
Unit:mm, Scale 1: 1.5 / mm
Ø 3.5
Healing Abutment
Unit:mm, Scale 1: 1.5 / mm
Ø 5.2
2.0 4.0
12 SimpleLine ll Product Catalog
Prosthetic Procedure 1
Impression Technique and Restoration Selection
Analog Analog
Ø4.8 / Ø6.5 Ø5.5 / Ø6.5
Page 15 Page 17
Burn-out Cylinder
Modification
Cemented Restoration
SimpleLine ll Product Catalog 13
Solid Abutment
Unit:mm, Scale 1: 1.5 / mm
5.5 7.0
H Art. No. 4.0
4.0 SOSAB 48 40 N
5.5 SOSAB 48 55 N
7.0 SOSAB 48 70 N
H Art. No.
5.5 7.0
4.0 SOSAB 65 40 N 4.0
5.5 SOSAB 65 55 N
7.0 SOSAB 65 70 N
14 SimpleLine ll Product Catalog
Dual Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Abutment Screw
6.5
Art. No. SOAAS 20 23
SimpleLine ll Product Catalog 15
7.0
Analog | Solid / Dual Abutment 4.0 5.5
SCA Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Application Ø4.8
Octa Non-octa
Application Ø6.5
Octa Non-octa
SimpleLine ll Product Catalog 17
12.8 12.8
18 SimpleLine ll Product Catalog
Restorative Kit
SCA Abutment
Lab Components
Art. No
Comfort Cap Impression Coping Analog Burn-out Cylinder
XSSOCAB 48 S CCC 55 CS CAN 55 SL
CIC 55 L CBC 55 SL CBC 55 BL
XSSOCAB 48 CCC 55 C CAN 55 LL
XSSOCAB 65 S CCC 65 CS CAN 65 SL
CIC 65 L CBC 65 SL CBC 65 BL
XSSOCAB 65 CCC 65 C CAN 65 LL
SimpleLine ll Product Catalog 19
Prosthetic Procedure 2
Impression Technique and Restoration Selection
Octa Non-octa
Octa Non-octa
Page 20 Page 20
Analog
Ø4.8 / Ø6.5
Page 22
Modification Modification
Octa SODPU 48 52 O
Ø4.8
Non-Octa SODPU 48 52 N
Octa SODPU 65 68 O
Ø6.5
Non-Octa SODPU 65 68 N Octa Non-octa
Ø6.8 Ø6.8
Octa Non-octa
Ø5.2 Ø5.2
Application Type Art. No.
Octa SODTF 48 52 O
Ø4.8
Non-Octa SODTF 48 52 N
Octa SODTF 65 68 O
Ø6.5 Octa Non-octa
Non-Octa SODTF 65 68 N
Ø6.8 Ø6.8
Octa Non-octa
Ø 5.5
Ø5.5
Application Ø4.8 | Octa
Octa
Angled Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
15˚
SOAAB4815Oand SOFX483810R
15˚ SOAAB 48 15 O
25˚ SOAAB 48 25 O
Octa Octa
15˚ SOAAB 65 15 O
25˚ SOAAB 65 25 O
Octa Octa
SimpleLine ll Product Catalog 23
Octa Non-octa
Octa Non-octa
24 SimpleLine ll Product Catalog
Metal-Casting Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Octa Non-octa
Octa Non-octa
SimpleLine ll Product Catalog 25
Temporary Abutment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Temporary Abutment - Ti
Ø5.2 Ø5.2 Ø6.8 Ø6.8
Application Type Art. No.
Octa SOTAB 48 52 TOG
Ø4.8 10.0 10.0 10.0 10.0
Non-octa SOTAB 48 52 TNG
Octa SOTAB 65 68 TOG
Ø6.5
Non-octa SOTAB 65 68 TNG Octa Non-octa Octa Non-octa
Octa SOTAB 65 68 PO
Ø6.5
Non-octa SOTAB 65 68 PN
Octa Non-octa Octa Non-octa
Fixture Analog
Ø4.8 Ø6.5
Screw Abutment
Screw Abutment
Ø4.8 / Ø6.5
Page 24
Closed Open
Tray Technique Tray Technique
Analog
Ø4.8 / Ø6.5
Page 26
Polishing Protector
Ø4.8 / Ø6.5 Temporary Restoration
Page 26
Ti-Retaining Screw
Page 26
Screw-Retained Restoration
SimpleLine ll Product Catalog 27
Screw Abutment
Unit:mm, Scale 1: 1.5 / mm
r
de
ol
yH
er
liv
De
Screw Abutment
Ø3.6 Ø4.3
Application Art. No.
2.0 2.0
Ø4.8 SOSAB 48 16 2.4 2.4
Ø6.5 SOSAB 65 16
Hex Hex
28 SimpleLine ll Product Catalog
Polishing Protector
Ø4.8 SOSPP 48 16
Ø6.5 SOSPP 65 16
Ø2.0
Ti-Retaining Screw
4.8
Art. No. SOSRS 16 T
Ø1.6
30 SimpleLine ll Product Catalog
Ti-Cylinder
Application Type Art. No.
Hex SOSTC 48 16 HG 8.3 8.3
Ø4.8
Non-hex SOSTC 48 16 NG
3.7 3.7
Hex SOSTC 65 16 HG
Ø6.5 Hex Non-hex
Non-hex SOSTC 65 16 NG
8.3 8.3
3.7 3.7
Hex Non-hex
Gold Cylinder
Application Type Art. No.
Hex SOSGC 48 16 H 12.0 12.0
Ø4.8
Non-hex SOSGC 48 16 N
Hex SOSGC 65 16 H
Ø6.5 Hex Non-hex
Non-hex SOSGC 65 16 N
12.0 12.0
Hex Non-hex
SimpleLine ll Product Catalog 31
12.0 12.0
Hex Non-hex
Burn-Out Cylinder
Application Type Art. No.
Hex SOSBC 48 16 H
12.0 12.0
Ø4.8
Non-hex SOSBC 48 16 N
Hex SOSBC 65 16 H
Ø6.5 Hex Non-hex
Non-hex SOSBC 65 16 N
12.0 12.0
Hex Non-hex
Prosthetic Procedure 4
Impression Technique and Restoration Type
Overdenture Procedure
Magnetic Assay
Page 31
Positioner Attachment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Positioner Abutment
Application G/H Art. No.
0 SOPAB 48 00
Ø4.8
1.0 SOPAB 48 10 1.0 1.0
0 SOPAB 65 00
Ø6.5
1.0 SOPAB 65 10
4.5
PIC
Positioner Analog
12.4
PAN
Positioner Attachment
Unit:mm, Scale 1: 1.5 / mm
MSHPN (Blue)
Non Tilting Type MSMPN (Orange)
MSLPN (Ivory) Retention Force 100gf 300gf 500gf 1,000gf
±5°
MSOP (White)
Ø4.8 SOBAB 48 00
Ø6.5 SOBAB 65 00
Ø3.8
Mini Ball Impression Coping
7.5
Art. No. ICA
Socket Spacer
Art. No. BIC3L 4.3
Magnetic Attachment
• Abutment screw is included. Unit:mm, Scale 1: 1.5 / mm
Implant Keeper
Ø5.0 Ø5.0
Application G/H Art. No.
2.0 SOMKP 48 20 D
2.0
Ø4.8 4.0
4.0 SOMKP 48 40 D
2.0 SOMKP 65 20 D
Ø6.5
4.0 SOMKP 65 40 D
Ø6.5 Ø6.5
2.0 4.0
SimpleLine ll Product Catalog 37
Surgical Kit
Unit:mm, Scale 1: 1.5 / mm
Kit includes
XPP 1622 48 XPP 1622 48 XPP 1622 48 XHD 25 H SOXHD 27 H XTS 40 XPP 1622 48
Drill
Unit: mm, Scale 1 : 1 / mm
Ø3.85
Ø4.4
29
Final Drill
Ø2.85
Diameter L Art. No.
Ø2.85 35 XFD 34 35 Ø3.3
Ø3.3 35 XFD 38 35
35
Ø3.85 33 XFD 43 33
Ø4.4 33 XFD 48 33 Ø3.85
Ø2.85 29 XFD 34 29
Ø4.4
Ø3.3 29 XFD 38 29
Ø3.85 29 XFD 43 29 33
Ø4.4 29 XFD 48 29
Ø2.85
Ø3.3
Ø3.85
Ø4.4
29
Round Bur
Instrument
Unit: mm, Scale 1 : 1 / mm
Adapter
Type L Art. No.
21
21 SOXHD 21 H
Hand-piece 24 SOXHD 24 H
24
27 SOXHD 27 H
21 SOXHD 21 W 27
Ratchet 24 SOXHD 24 W
27 SOXHD 27 W
21
24
27
Mount Adapter
Type L Art. No.
Hand-piece 19 SOXMA 19 19
Ratchet 19 SOXRA 19
19
Manual 26 XHD 26 T
26
40 SimpleLine ll Product Catalog
Instrument
Unit: mm, Scale 1 : 1 / mm
Path Pin
L Art. No.
18.3
18.3 SOXMFPAS
23.3 SOXMFPA
23.3
Parallel Pin
Ø4.8 Ø1.6
Diameter L Art. No.
21.5
Ø4.8 21.5 XPP1622 48
Ø6.5 21.5 XPP1622 65 Ø6.5 Ø1.6
21.5
Drill Extension
Art. No. XDE
26
Tissue Punch
Art. No. XTS 40
Ratchet
Art. No. XRCA1
SimpleLine ll Product Catalog 41
Prosthetic Kit
B.WRENCH
ADAPTER
XNTW
42 SimpleLine ll Product Catalog
21
28
Adapter
Type L Art. No. 21
Hand-piece 21 XMAA 1
Torque Wrench 21 XHD 21 W
21
Mini Ball 21 IPST 21 W
21
Slot Driver
Art. No. SDA 25 R
25
SURGICAL MANUAL
Fixture Installation 46
Fixture Connection 46
Warnings 48
SimpleLine ll Product Catalog 45
8 10 12 14 16
Final drill
First Second
guide guide
drill drill 3.4 3.8 4.3 4.8
Ø2.2 Ø2.6
Ø2.85 Ø3.3 Ø3.85 Ø4.4
Platform: Ø4.8
Body: Ø3.4
Platform: Ø4.8
Body: Ø3.8
Platform: Ø6.5
Body: Ø4.8
46 SimpleLine ll Product Catalog
Fixture Installation
Platform: Ø6.5 / Body: Ø4.8 (800~1,200rpm / 30~45N·cm)
Ø6.5
10mm
Ø4.8
Fixture Connection
By hand-piece By ratchet
20rpm / 35N·cm
SimpleLine ll Product Catalog 47
Connection
Hand-piece Ratchet The ratchet adapter and the fixture interal octa must be
adapter adapter firmly connected together.
01 A
ll instruments, immediately after use, must be pre-soaked for a few minutes in a germicidal bath to loosen and
prevent debris from attaching to instruments. Do not soak over-night.
02 Scrub with a soft brush to remove any debris.
03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.
04 If using an ultrasonic cleaner, wrap drills in a 2 x 2 gauze to prevent the drills from rubbing against each other.
05 Rinse thoroughly under warm water.
06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.
07 Dry completely and place back into kit.
08 Always check for damage or corrosion after rinsing and drying.
09 Seal the tray in a sterilization pouch.
10 Sterilize using a steam autoclave at 121°C / 250℉ for 30 minutes or refer to manufacture's recommendations.
11 Store in a dry area at room temperature.
Warnings
Warnings
Dental implant surgery and restoration involve complex dental procedures. Appropriate and adequate
training in proper technique is strongly recommended prior to use.
• Improper medical examination and / or treatment plan can result in implant failure and / or loss of supportive bone.
• Improper initial stability and / or excessive occlusal forces during healing period may lead to osseointergration failure.
• Excessive insertion torque may lead to a mechanical failure or a implant biologic failure due to bone compression and
necrosis.
• When forces or loads are greater than its design, implant or abutment fracture could occur. Therefore clinicians
should make careful decisions in regards to clinical treatment planning to minimize the risk of fracture. Appropriate
implant quantity, occlusal interface and a nightguard are essential. Potential excessive loading conditions may include
the following:
PROSTHESIS MANUAL
Types of Abutment 50
Prosthetic Procedure 1 51
Abutment Level- Solid / Dual Abutment 52
Abutment Level- SCA Abutment 55
Prosthetic Procedure 2 58
Fixture Level [Pick-up Type]- Dual Abutment 59
Fixture Level [Transfer Type]- Dual Abutment 62
Fixture Level- SCA Abutment 65
Fixture Level- Dual Milling Abutment 67
Fixture Level- Angled Abutment 69
Fixture Level- Direct Casting Abutment 71
Prosthetic Procedure 3 73
Abutment Level- Screw Abutment 74
Prosthetic Procedure 4 79
Positioner 80
Ball Attachment 82
Magnetic Attachment 84
50 SimpleLine ll Product Catalog
Types of Abutment
One-Piece Two-Pieces
Ti Plastic
· Dual Abutment
Positioner Ball Magnetic
· Solid Abutment Abutment level
· SCA Abutment Overdenture
· Dual Abutment
· SCA Abutment
· Dual Milling Abutment
· Angled Abutment (15°/25°) Fixture level
· Direct-Casting Abutment
· Metal-Casting Abutment
· Temporary Abutment
· Positioner
· Ball For denture use
· Magnetic
SimpleLine ll Product Catalog 51
Prosthetic Procedure 1
Impression Technique and Restoration Selection
Analog Analog
Ø4.8 / Ø6.5 Ø5.5 / Ø6.5
Burn-out Cylinder
Modification
Cemented Restoration
52 SimpleLine ll Product Catalog
Clinical Procedure
Chairside
Affix the impression coping on Apply the impression material. Take the impression.
the abutment.
Image of the set final impression Place comfort cap over the abutment.
with impression coping.
SimpleLine ll Product Catalog 53
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Lab Side
Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
embedded impression coping. locked into the impression coping
(line up the flat side of analog to the flat
side of the coping).
Create the master model. Snap on the burn-out cylinders Cut the cylinder after measuring proper
securely onto the analogs. height based on the proximity of the
opposing teeth.
Prepare for wax-up by affixing the Completion of wax-up. Produce the metal framework.
plastic bar.
54 SimpleLine ll Product Catalog
Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.
Final prosthesis. Create an access hole when the Image of the extended margin around
burn-out cylinder is used for the wax-up. the metal framework.
Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.
Clinical Procedure
Chairside
Affix the impression coping on Apply the impression material. Take the impression.
the abutment.
Image of the set final impression Place comfort cap over the abutment.
with impression coping.
56 SimpleLine ll Product Catalog
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Lab Side
Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
embedded impression coping. locked into the impression coping (line
up the flat side of analog to the flat
side of the coping).
Create the master model. Snap on the burn-out cylinders Cut the cylinder after measuring proper
securely onto the analogs. height based on the proximity of the
opposing teeth.
Prepare for wax-up by affixing the Completion of wax-up. Produce the metal framework.
plastic bar.
SimpleLine ll Product Catalog 57
Shave off the extended margin by us- Metal framework and reamer. Use the reamer to eliminate the "Lip"
ing the rubber wheel. created by the "snap-on" mechanism.
Final prosthesis. Create an access hole when the Image of the extended margin around
burn-out cylinder is used for the wax-up. the metal framework.
Shave off of the extended margin by Metal framework and reamer. Use the reamer to eliminate the "Lip"
using the rubber wheel. created by the "snap-on" mechanism.
Prosthetic Procedure 2
Impression Technique and Restoration Selection
Octa Non-octa
Octa Non-octa
Analog
Ø4.8 / Ø6.5
Modification Modification
Clinical Procedure
Chairside
Take the impression. Remove the screw before removing Image of the set final impression
the impression tray. with impression coping.
60 SimpleLine ll Product Catalog
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
Dual Abutment cutting for Cementation Type
height adjustment
Lab Side
Connect analogs with the Soft tissue modeling. Create the master model.
embedded impression coping.
Assemble the dual abutment. If deemed necessary, abutment milling Fabricate the positioning jig
is possible.
Chairside
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the intraoral occlusal adjustment.
and then tighten it with 25~30N·cm.
Re-tighten it after 15 minutes.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SCRP- Chairside
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the intraoral occlusal adjustment.
and tighten with to 25~30N·cm.
Re-tighten it after 15 minutes.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
62 SimpleLine ll Product Catalog
Clinical Procedure
Chairside
Apply the impression material. Take the impression. Image of the set final impression
with impression coping.
SimpleLine ll Product Catalog 63
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
Dual Abutment cutting for Cementation Type
height adjustment
Lab Side
Impression coping and analog Make sure the analogs are securely Soft tissue modeling.
connection. And insert impression seated in the impression coping (line
coping into the impression. up the flat side of analog to the flat
side of the coping).
Create the master model. Examine the soft tissue condition after Assemble the dual abutment.
the retrieval of the impression coping.
If deemed necessary, abutment milling Fabricate the positioning jig. Fabricate the cap with pattern resin.
is possible.
64 SimpleLine ll Product Catalog
Chairside
Use the positioning jig to transfer Cement the final prosthesis and make
the abutment from the model to the occlusal adjustment. Place wax into
intraoral and tighten it with 25~30N·cm. the opening of the abutment to protect
Re-tighten after 15 minutes. the screw head prior to the composite
sealing.
Create an access hole for the pick-up Completion of Wax-up. Metal framework.
coping screw.
SCRP- Chairside
Final prosthesis. Use positioning jig to transfer Cement the final prosthesis and make
abutment from the model to the in- occlusal adjustment. Place wax into
traoral and tighten it with 25~30N?cm. the opening of the abutment to protect
Re-tighten after 15 minutes. the screw head prior to the composite
sealing.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 65
Clinical Procedure
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Lab Analog Connection Assemble the Burn-out Cylinder Crown Wax-up Final Restoration
SCA Abutment cutting for Cementation Type
height adjustment
Lab Side
Connect analogs with the Soft tissue modeling. Create the master model.
embedded impression coping.
66 SimpleLine ll Product Catalog
Assemble the SCA abutment. If deemed necessary, abutment milling Fabricate the positioning jig
is possible.
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the in- clusal adjustment. Place wax into the open-
traoral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it after 15 minutes. head prior to the composite sealing.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
SCRP- Lab Side case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the in- occlusal adjustment. Place wax into the
traoral and tighten it with 25~30N·cm. opening of the abutment to protect the
Re-tighten it after 15 minutes. screw head prior to the composite sealing.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 67
Clinical Procedure
Laboratory Procedure
Lab Analog Connection Dual Milling Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type
Lab Side
Connect analogs with the Soft tissue modeling. Create the master model.
set impression material.
68 SimpleLine ll Product Catalog
Assemble the dual milling abutment. Milled the abutment to an Fabricate the positioning jig
appropriate size.
Fabricate the cap with pattern resin. Completion of wax-up. Metal framework.
Chairside
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the in- clusal adjustment. Place wax into the open-
traoral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it aAfter 15 minutes. head prior to the composite sealing.
* In the process of seating the prosthesis, the components can be rebounded by gingival tissue. In that
case, it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SimpleLine ll Product Catalog 69
Clinical Procedure
Laboratory Procedure
Lab Analog Connection Angled Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type
Lab Side
Impression coping with analog Soft tissue formation and fabrication Unscrew and separate the impression
connections. of master model. from the model.
70 SimpleLine ll Product Catalog
Create the master model. Assemble the angled abutment. Milled the abutment to an appropriate
size and fabricate the positioning jig.
Fabricate the cap with pattern resin. Completion of wax-up. Metal or zirconia framework.
Chairside
Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make
abutment from the model to the occlusal adjustment. Place wax into the
intraoral and tighten it with 25~30N·cm. opening of the abutment to protect the
Re-tighten it after 15 minutes. screw head prior to the composite sealing.
SimpleLine ll Product Catalog 71
Clinical Procedure
Laboratory Procedure
Lab Analog Connection Direct-Casting Abutment Modification Crown Wax-up Final Restoration
Connection Cementation Type
Lab Side
Impression coping with analog Soft tissue formation and fabrication Unscrew and separate the impression
connections. of master model. from the model.
72 SimpleLine ll Product Catalog
Assemble the direct casting abutment. Completed customized abutment. Fabricate the positioning jig.
Chairside
---Final prosthesis. Use positioning jig to transfer the Cement the final prosthesis and make oc-
abutment from the model to the int- clusal adjustment. Place wax into the open-
raral and tighten it with 25~30N·cm. ing of the abutment to protect the screw
Re-tighten it after 15 minutes. head prior to the composite sealing.
Prosthetic Procedure 3
Impression Technique and Restoration Selection
Screw Abutment
Screw Abutment
Ø4.8 / Ø6.5
Closed Open
Tray Technique Tray Technique
Analog
Ø4.8 / Ø6.5
Polishing Protector
Ø4.8 / Ø6.5 Temporary Restoration
Ti-Retaining Screw
Screw-Retained Restoration
74 SimpleLine ll Product Catalog
Clinical Procedure
Chairside
Screw abutment and delivery holder. Select and seat an appropriate screw Tighten it with 25~30N·cm.
abutment with delivery holder. Re-tighten it after 15 minutes
with screw abutment adapter.
Screw abutment transfer copings Connect the impression coping for Apply the impression material.
(abutment level). abutment level impression.
Take the impression. Image of the set final impression Place comfort cap over the screw
with impression coping. abutment.
SimpleLine ll Product Catalog 75
Laboratory Procedure
Lab Analog Connection Cylinder Connection Modification Crown Wax-up Final Restoration
Screw Retained
Lab Side
Insert analogs into the Make sure the analogs are securely Soft tissue modeling.
set impression. seated in the impression coping (line
up the flat side of analog to the flat
side of the coping).
Create the master model. Remove the impression coping. Connect the screw abutment cylinder
and tighten it with Ti-retaining screw.
Trim cylinder after measuring proper Connect the plastic bar in the middle Completion of wax-up.
height based on the proximity of the of trimmed burn-out cylinders to help
opposing teeth.. support the wax pattern.
Wax pattern may experience
shrinkages.
76 SimpleLine ll Product Catalog
Gold framework. Use the reamer to remove the "Lip" in Completion of gold framework.
the interior of the metal framework.
In case of the following: In order to unscrew, create access Unscrew, and remove the prosthesis
screw loosening or hole on the occlusal surface with a bur. from the patient's mouth.
prosthesis repair
Both cemented prosthesis and Finish the repair and seat it inside Tighten the prosthesis with
abutments are removed. the patient's mouth. 25~30N·cm with a screw driver
* It is recommended that the abutment screw is
retightened after 15 minutes.
Place a small piece of cotton to Fill the remaining access space with Final prosthesis.
cover the head of the screw. a resin.
78 SimpleLine ll Product Catalog
Remove the screw completely with Apply cement to the prosthesis. Place it back into the patient's mouth.
screw driver and remove prosthesis
* In case of screw abutment connection,
from the patient's mouth.
Ti-Retain screw has to be tightened with) 10N·cm.
Unscrew and remove the excessive Finish the repair and seat it inside Tighten the prosthesis with
cement. the patient's mouth. 25~30N·cm with a screw driver.
Adding volume to the interproximal Create access hole on the occlusal Unscrew and remove the cemented
surface to repair loosening. surface with a bur. prosthesis with abutment from the
patient's mouth.
Add resin to the prepared space Screw back in the prosthesis and
on the contact surface. perform light curing. Aftermath, polish
the contact surface.
Prosthetic Procedure 4
Impression Technique and Restoration Type
Overdenture Procedure
Magnetic Assay
Positioner
Chairside
Connect the Positioner Abutment onto Affix the impression coping on the Take impression for the production of
the fixture. Positioner Abutment. the individual tray.
Produce the individual tray for After connecting the Positioner Take the final impression with the
denture impression. Abutment and the impression coping prepared individual tray.
together, apply the impression material.
After the impression material is set, Image of the set final impression
discard the individual tray. (with impression coping).
Lab side
Positioner Analog. Insert the Positioner Analog into the Create the master model.
embedded impression coping.
Positioner
Case 1 Chairside
Secure spaces for the female sockets. Place the "block out spacer" on the Posi- Connect the metal socket onto the
tioner Abutment in the patient's mouth. Positioner Abutment.
Apply a small amount of resin into the Position the denture in the mouth and Remove the white plastic socket (100gf)
space created for the metal socket. wait until the resin is completely set. using the positioner tool and replace
with a regular plastic socket of a desired
retention force (300, 500 or 1000gf).
Remove the denture after the resin is Remove the block out spacer from Polish and the overdenture
fully set. Image of the denture the patien's mouth. is complete.
with the metal socket.
Case 2 Chairside
Create holes for the placement Place the "block out spacer" on the Connect the metal socket onto the
of the metal sockets. Positioner Abutment in the intraoral. Positioner Abutment.
Examine for interference Apply the resin into the holes and wait Remove the white plastic socket (100gf)
between the inner surface of the until it is completely set. using the positioner tool and replace
with a regular plastic socket of a desired
holes and the female sockets. retention force (300, 500 or 1000gf).
Apply additional resin around the Apply resin around the metal socket. Polish and the overdenture
metal socket where there is a short- is complete.
age of resin.
82 SimpleLine ll Product Catalog
Ball Attachment
Chairside
Connect the Ball Abutment with Affix the impression coping Take impression for the production of
the fixture. on the Ball Abutment. the individual tray.
Produce the individual tray for Apply the impression material. Take the final impression with the
denture impression. prepared individual tray.
After the impression material is set, Image of the set final impression
discard the individual tray. (with impression coping).
Lab side
Ball Analog. Insert the analogs into the embedded Create the master model.
impression coping.
Ball Attachment
Case 1 Chairside
Secure spaces for the female sockets. Connect the female sockets to the Apply small amount of the resin
Ball Abutment in the intraoral. into the secured area.
Position the denture in the mouth and Female sockets are placed Polish and the overdenture
wait until the resin is completely set. in the denture. is complete.
Case 2 Chairside
Create holes for the placement Connect the female sockets to the Examine for interference between the
of the female sockets. Ball Abutment in the intraoral. inner surface of the holes and the
female sockets.
Apply the resin into the holes and wait Place the female sockets. Apply resin around the female sockets.
until it is completely set.
Magnetic Attachment
Chairside
Remove the Healing Abutment. Connect implant keeper with the fix- Implant keepers connected with
ture and tighten it with 25~30 N·cm. the fixtures.
Position the magnetic assay on the Secure spaces for the magnetic as- Examine for interference between inner
implant keeper. says. divets of the denture and the magnets.
Case 1
Apply resin on the divets of the Position the denture into the mouth Position the denture into the mouth
denture's inner surface. and wait until the resin is completely and wait for initial setting.
set.
Remove the denture and apply resin After the resin is completely set,
around the magnets. remove excess. Polish and the
overdenture is complete.
SimpleLine ll Product Catalog 85
Magnetic Attachment
Case 2
Create holes for the placement of Examine for interference between the Apply small amount of resin into the
the magnets. inner surface of the holes and hole.
the magnets.
Position the denture in the mouth and After initial setting, remove denture Add the resin around the magnets.
wait until the resin is completely set. from the mouth.
SimpleLine II
Product/Manual Catalog