96M16963 • KEYENCE never warrants the function or

performance of the IV3/IV2/IV Series if it is used


Copyright (c) 2021KEYENCE CORPORATION. All rights reserved. in manner that differs from the IV3/IV2/IV Series
16963GB 2071-1 96M16963 Printed in Japan
specifications contained in this instruction
manual or if the IV3/IV2/IV Series is modified by
yourself.
PC software for IV3/IV2/IV Series • When the IV3/IV2/IV Series is used in
combination with other instruments, functions

IV3-H1 and performance may be degraded, depending


on operating conditions and the surrounding
environment.
• Do not subject the controller or connected
Instruction Manual devices to a sudden change in temperature.
It may cause condensation and may damage
Read this manual before using the product in order to instruments or peripherals.
achieve maximum performance. • Remove the power cable from the power supply if
Keep this manual in a safe place after reading it so that it you do not use this product for a long time.
can be used at any time.
For details of functions, refer to the User’s Manual (PC Software) Important Instructions
for each IV series. Observe the following precautions to prevent malfunction
y The User’s Manual for each IV series can be downloaded and to ensure proper use.
from the KEYENCE website: www.keyence.com/glb
Precautions on use
Symbols • The power of this product and instruments
The following symbols alert you to important messages. connected to this product must be turned off
when the cable is to be installed or removed.
Be sure to read these messages carefully. Failure to do so may cause an electric shock or
Indicates a hazardous situation which, if not product damage.
avoided, will result in death or serious injury. • Use this product with the correct voltage. Failure
to do so may cause a product damage.
Indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
Measures to be taken when an abnormality
Indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury. occurs
Indicates a situation which, if not avoided, could In the following cases, turn the power OFF
result in product damage as well as property damage. immediately. Using the IV3/IV2/IV Series in an
abnormal condition could cause fire, electric shock,
Indicates cautions and limitations that must be or malfunction.
followed during operation. Contact our office for repair.
• If water or debris enters the IV3/IV2/IV Series.
Indicates additional information on proper operation. • If the IV3/IV2/IV Series is dropped or the case is
damaged.
Indicates tips for better understanding or useful information. • If abnormal smoke or odor emanates from the IV3/
IV2/IV Series.
Safety Information
Precautions on installation
General Precautions Only engineers who are knowledgeable about
networks should attempt connection when
• Do not use this product for the purpose to protect connecting the IV3/IV2/IV series to a network.
a human body or a part of a human body.
• Do not use this product in a hazardous location
and/or potentially explosive atmosphere. Checking the Package Contents
• Do not use this product in an application that may
cause death, serious injury or serious property PC software for IV3/IV2/IV series
damage due to a failure with this product should
occur, such as nuclear power plants, on aircraft, • IV3-H1
trains, ships, or vehicles, used within medical Instruction Manual x 1 (This manual)
equipment, playground equipment, roller coasters
and other rides, etc.
• If the product is used in a manner not specified DVD × 1
by this manual, the protection provided by the
product may be impaired.
• You must perform a sufficient risk assessment
for the machine where this product is to be
installed prior to installing this product. Provide
appropriate protective fail-safe measures on the
machine independent from this product in case a
failure with this product should occur.
Before starting or operating the system, check to
make sure all system functions are working properly.

1 IV3 Series (PC Software) - IM_E


Connecting the IV3 Series to a PC

Connecting to one sensor


z Ultra compact type z Built-in amplifier type
Cable for connecting sensor head to amplifier
OP-88648 (2 m)
OP-88649 (5m)
OP-88650 (10m)
Sensor amplifier
IV3-G120

Ethernet cable
Sensor head OP-88664 (2m)
OP-88665 (5m)
OP-88666 (10m)
LAN cable
OP-87950 (1m)
OP-87951 (3m)
OP-87952 (5m)
OP-87953 (10m)

Connecting to multiple sensors


Ethernet switch

LAN cable
OP-87950 (1m)
OP-87951 (3m)
OP-87952 (5m)
OP-87953 (10m)

Ethernet cable
OP-88664 (2m)
Sensor amplifier OP-88665 (5m)
IV3-G120 OP-88666 (10m)

Cable for connecting


sensor head to amplifier
• OP-88648 (2 m)
• OP-88649 (5m)
• OP-88650 (10m)

Sensor head PLC


• IV3-G500CA Built-in amplifier type (Communication network)
• IV3-G500MA • IV3-500CA FTP Server
• IV3-G600CA • IV3-500MA
• IV3-G600MA • IV3-600CA
• IV3-600MA

For details about how to connect to the IV2 series and IV series, see the applicable user manual.

IV3 Series (PC Software) - IM_E 2


Installing the Software Changing the PC Settings
(IP Address Settings)
Required environment for the PC to be
connected • This section describes installation using the
example for Windows 10.
“Specifications” (page 4)For system requirements, • Log on with a user who has administrative
refer to “Specifications” (Page 4). privileges.
• Auto aquisition of IP address (DHCP server)
cannot be used due to the inability to connect
Installation with the sensor.

• This section describes installation using the


example for Windows 10. 1 Open the Control Panel.
• Exit or finish all other running software before the
installation. 2 Click ([Network and Internet]) - [Network and
• Log on with a user who has administrative Sharing Center].
privileges.
• If the user account control window appears during 3 Click [Change adapter settings] on the upper left
the installation, click the [Continue] button. of the window.
• If you have logged on with a user account that
does not have administrative privileges, input a 4 Right-click the [Local Area Connection] icon and
user account with administrative privileges and select [Properties] from the displayed menu.
the password.
5 Select [Internet Protocol Version 4 (TCP/IPv4)] and
1 Turn ON the power of the PC and start Windows. click the [Properties] button.

2 Insert the “IV3-H1” disc into the media drive. 6 Select [Use the following IP address] and input
The selection window of an installation program activates the IP address and subnet mask.
using the auto run function of the PC. If the selection
window does not display, open the media drive from My
Computer and double-click “IV3 Launcher.exe”.

3 Select the software to install.


• When using the IV3 Series, click [IV3-Navigator].
• When using the IV2 Series, Click [IV2-Navigator].
• When using the IV Series, Click [IV-Navigator].

Setup example
The “InstallShield Wizard” window opens. • IP address: 192.168.10.1
• Subnet mask: 255.255.255.0
4 Follow the instructions in the window. To connect with the existing network, input the
IP address that was assigned by the network
administrator.

7 After setting is completed, click the [OK] button


and close all windows.

5 After the completion window for InstallShield


Wizard is displayed, click the [Finish] button.

6 Close the [IV3-Navigator Installer] window.


If using the IV2 Series or the IV Series, please
install the software corresponding to the device
you are using.

7 Remove the installation DVD.

3 IV3 Series (PC Software) - IM_E


Specifications

Model IV3-H1

Supported sensor IV3 series, IV2 series, IV series

Recording software For IV3 Series: IV3-Navigator, For IV2 Series: IV2-Navigator, For IV Series: IV-Navigator

Interface Equipped with the Ethernet (1000BASE-T) interface

Windows 10 Home/Pro/Enterprise
OS*1 Windows 7 (SP1 or higher) Home Premium/Professional/Ultimate;
either OS above needs to be pre-installed

Processor Needs to be compliant with system requirements for OS.


System
Memory capacity 4 GB or more
requirements
Required capacity for
4 GB or more
installation

Monitor Resolution: 1024 x 768 pixel or higher, Display: High Color (16bit) or higher

.NET Framework 4.5.2 must be installed*2


Operating conditions
Microsoft Visual C++ 2017 Redistributable Package must be installed.*2

*1 Supports 32-bit and 64-bit versions.


*2 If this software is not installed, it will be automatically installed when IV3-H1 is installed.

WARRANTIES AND DISCLAIMERS Cautions


(1) KEYENCE warrants the Products to be free of defects in materials and (1) Unauthorized reproduction of this manual in whole or part is prohibited.
workmanship for a period of one (1) year from the date of shipment. If any (2) The contents of this manual may be changed for improvements without prior
models or samples were shown to Buyer, such models or samples were notice.
used merely to illustrate the general type and quality of the Products and not (3) An utmost effort has been made to ensure the contents of this manual are as
to represent that the Products would necessarily conform to said models or complete as possible. If there are any mistakes or questions, please contact a
samples. Any Products found to be defective must be shipped to KEYENCE KEYENCE office listed in the back of the manual.
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and (4) Regardless of item (3), KEYENCE will not be liable for any effect resulting from
examination. Upon examination by KEYENCE, KEYENCE, at its sole option, the use of this unit.
will refund the purchase price of, or repair or replace at no charge any Products (5) Any manuals with missing pages or other paging faults will be replaced.
found to be defective. This warranty does not apply to any defects resulting from
any action of Buyer, including but not limited to improper installation, improper The company names and product names used in this manual are registered
interfacing, improper repair, unauthorized modification, misapplication and trademarks or the trademarks of their respective companies
mishandling, such as exposure to excessive current, heat, coldness, moisture,
vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer’s responsibility to ascertain the
fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples (“Products/Samples”) supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/ Samples.

(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE


PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE
AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY
FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY
DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,
LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS
OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S
CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.

BUYER’S TRANSFER OBLIGATIONS:


If the Products/Samples purchased by Buyer are to be resold or delivered to a
third party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to
Buyer pertaining to the Products/Samples.