You are on page 1of 4

96M13285 yyKEYENCE never warrants the function or

performance of the IV Series if it is used


in manner that differs from the IV Series
specifications contained in this instruction
PC software for IV series manual or if the IV Series are modified by
yourself.

IV-H1 yyWhen the IV Series is used in combination with


other instruments, functions and performance
may be degraded, depending on operating
conditions and the surrounding environment.
Instruction Manual yyDo not place the instruments, including
Read this manual before using the product in order to peripherals, under rapid temperature
achieve maximum performance. change. It may cause condensation and may
Keep this manual in a safe place after reading it so that it damage instruments or peripherals.
can be used at any time. yyRemove the power cable from the power supply
For details of functions, refer to the User’s Manual (PC if you do not use this product for a long time.
Software).
yyThe User’s Manual (PDF) can be viewed inside the folder Important Instructions
where the IV-Navigator was installed or from the “Help”
menu of the IV-Navigator. Observe the following precautions to prevent malfunction
and to ensure that it is used properly.
Symbols
Precautions on use
The following symbols alert you to important messages.
Be sure to read these messages carefully. yyThe power of this product and instruments
connected to this product must be turned off when
It indicates a hazardous situation which, if not the cable is to be installed or removed. Failure to do
avoided, will result in death or serious injury. so may cause an electric shock or a product damage.
It indicates a hazardous situation which, if not yyUse this product in the correct supply voltage.
avoided, could result in death or serious injury. Failure to do so may cause a product damage.

It indicates a hazardous situation which, if not


avoided, could result in minor or moderate injury. Measures to be taken when an abnormality occurs
It indicates a situation which, if not avoided, In the following cases, turn the power OFF
could result in product damage as well as immediately. Using the IV Series in an abnormal
property damage. condition could cause fire, electric shock, or
malfunction. Contact our office for repair.
It indicates cautions and limitations that must yyIf water or debris enters the IV Series.
be followed during operation. yyIf the IV Series is dropped or the case is damaged.
yyIf abnormal smoke or odor emanates from
It indicates additional information on proper the IV Series.
operation.
It indicates tips for better understanding or useful Precautions on installation
information.
When connecting to a network, let engineers
who are knowledgeable about networks
Cautions handle it.
(1) Unauthorized reproduction of this manual in whole or
part is prohibited. Checking the Package Contents
(2) The contents of this manual may be changed for
improvements without prior notice.
(3) An utmost effort has been made to ensure the contents
PC software for IV series
of this manual are as complete as possible. If there are yyIV-H1
any mistakes or questions, please contact a KEYENCE Instruction Manual × 1 (This manual)
office listed in the back of the manual. Starting Guide × 1
(4) Regardless of item (3), KEYENCE will not be liable for
any effect resulting from the use of this unit. CD-ROM × 1
(5) Any manuals with missing pages or other paging faults
will be replaced.
The company names and product names used in this manual are
registered trademarks or the trademarks of their respective companies.

Safety Information for IV Series

General Precautions
yyDo not use this product for the purpose to
protect a human body or a part of human body.
yyThis product is not intended for use as an explosion-
proof product. Do not use this product in a hazardous
location and/or potentially explosive atmosphere.
yyYou must verify that the IV Series are
operating correctly in terms of functionality
and performance before the start and the
operation of the IV Series.
yyWe recommend that you take substantial
safety measures to avoid any damage in the
event of a problem occurring.

1 IV Series (PC Software) - IM_E


Connecting the Sensor and PC

Connecting directly
Sensor head/amplifier cable for ultra compact model
OP-87903 (2 m)
OP-87904 (5 m)
OP-87905 (10 m)

Ultra compact model


Sensor amplifier
(Main)

Ethernet cable
OP-87907 (1 m)
OP-87457 (2 m)
LAN cable OP-87458 (5 m)
OP-87950 (1 m) OP-87459 (10 m)
Ultra compact OP-87951 (3 m)
model OP-87952 (5 m)
Sensor head OP-87953 (2 m)
Sensor
Built-in amplifier model

For details on connection using the Ultra compact model Sensor amplifier (Expansion), refer to “User’s Manual (PC Software)”.

Connecting via a network

Ethernet switch

LAN cable
OP-87950 (1 m)
OP-87951 (3 m)
OP-87952 (5 m)
OP-87953 (10 m)

Sensor head/
amplifier cable for
ultra compact model Ethernet cable
OP-87903 (2 m) OP-87907 (1 m)
OP-87904 (5 m) Ultra compact model OP-87457 (2 m)
OP-87905 (10 m) Sensor amplifier OP-87458 (5 m)
(Main) OP-87459 (10 m)

Ultra Compact model


Sensor head
Sensor
Built-in amplifier model
LAN cable
OP-87950 (1 m)
OP-87951 (3 m)
OP-87952 (5 m)
OP-87953 (10 m)

For details on connection using the Ultra compact model Sensor amplifier (Expansion), refer to “User’s Manual (PC Software)”.

IV Series (PC Software) - IM_E 2


Installing the Software Changing the PC Settings
(IP Address Settings)
Required environment for the PC to be connected
yyLog on with a user who has administrative
For system requirements, refer to “Specifications” (Page 4). privileges.
yyAuto aquisition of IP address (DHCP server)
cannot be used due to the inability to
Installing the IV-Navigator (IV-H1) connect with the sensor.
This section describes the procedure for installing the IV-
Navigator (IV-H1) for IV Software on the PC.
yyThis section describes the installation using For Windows 7
an installation example for Windows 7.
yyExit or finish all other running software 1 Open the Control Panel.
before the installation.
yyLog on with a user who has administrative 2 Click ([Network and Internet]) - [Network and
Sharing Center].
privileges.
yyIf the user account control window appears
during the installation, click the [Continue]
3 Click [Change adapter settings] on the upper left
on the window.
button.
yyIf you have logged on with a user account
that does not have administrative privileges,
4 Right-click the [Local Area Connection] icon and
select [Properties] from the displayed menu.
input a user account with administrative
privileges and the password. 5 Select [Internet Protocol Version 4 (TCP/IPv4)] and
click the [Properties] button.
1 Turn ON the power of the PC and start Windows.
6 Select [Use the following IP address] and input
2 Insert the IV-H1 disc into the media drive.
The installation program activates by the auto run
the IP address and subnet mask.

function of the PC, and the InstallShield Wizard window


opens.
If the installation program does not activate, open the
media drive from the My Computer and double-click
"setup.exe".

3 Follow the instructions in the window.

yyIP address : 192.168.10.1


yySubnet mask : 255.255.255.0
For direct connection, set an arbitrary IP
address (The above is an example).
4 After the completion window for InstallShield To connect with the existing network, input the
Wizard is displayed, click the [Finish] button. IP address that was assigned by the network
5 Remove the installation CD. administrator.

7 After the setting is completed, click the [OK]


button and close all windows.

For Windows XP
1 Open the Control Panel.
2 Click [Network and Internet Connections] and
double-click [Network Connections].

3 Right-click the [Local Area Connection] icon and


select [Properties] from the displayed menu.

4 Select [Internet Protocol (TCP/IP)] and click the


[Properties] button.

3 IV Series (PC Software) - IM_E


5 Select [Use the following IP address] and input Warranties and Disclaimers
the IP address and subnet mask.
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and not
to represent that the Products would necessarily conform to said models or
samples. Any Products found to be defective must be shipped to KEYENCE
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option,
will refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting from
any action of Buyer, including but not limited to improper installation, improper
interfacing, improper repair, unauthorized modification, misapplication and
mishandling, such as exposure to excessive current, heat, coldness, moisture,
vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
fitness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specifications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/ Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
yyIP address : 192.168.10.1 PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
yySubnet mask : 255.255.255.0 IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
For direct connection, set an arbitrary IP PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE
address (The above is an example). AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY
To connect with the existing network, input the FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
IP address that was assigned by the network CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY
DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,
administrator. LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS
OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF

6 After the setting is completed, click the [OK] SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
button and close all the windows. INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S
CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
Specifications may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a
Model IV-H1 third party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to
Interface Equip the Ethernet (100BASE-TX) interface Buyer pertaining to the Products/Samples.
E 1101-3
Windows 10 Home/Pro/Enterprise *1
Windows 7 Home Premium/
OS Professional/Ultimate *1
Windows XP Professional/HomeEdition;
either of OS above needs to be pre-installed
Japanese / English / Deutsch /
Chinese (Simplified) / Chinese (Traditional) /
Languages
Italian / French / Spanish / Portuguese /
Korean
Windows 10/7:
System requirements

Needs to be compliant with system


requirements for OS.
Processor
Windows XP:
Pentium III or better
Clock speed 1 GHz or faster
Windows 10/7:
Needs to be compliant with system
Memory requirements for OS.
capacity Windows XP:
512 MB or more (1 GB or more is
recommended)
Required
capacity for 1 GB or more
installation
Resolution 1024 x 768 pixel or higher,
Monitor
Display color High Color (16bit) or higher
Operating .NET Framework 4.0 or 4.5 needs to be
conditions instaxlled *2
*1 Supported for 32bit and 64bit version.
*2 If .NET Framework 4.0 or 4.5 is not installed,
.NET Framework 4.0 will be installed automatically when
IV-H1 installed.

IV Series (PC Software) - IM_E 4


Copyright (c) 2018 KEYENCE CORPORATION. All rights reserved.
13285E 1048-3 96M13285 Printed in Japan
*96M13285-3*

You might also like