You are on page 1of 14

HARNESS AND

PERIPHERICAL
UNITS INFORMaTION

Last Update: 02/2022


CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update
at any time. CRE TECHNOLOGY does not assume any responsibility for its use. E & O E.

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
NOTE

Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or
servicing this equipment. Apply all plant and safety instructions and precautions. Failure to follow instructions can cause
personal injury and/or property damage.
Motors, turbines and any other type of generator must be equipped with protections (overspeed, high temperature, low
pressure… depending on the power plant).
Any changes of the normal use of the equipment can cause human and material damage.

For further information, please contact your CRE Technology distributor or the After-Sales Service Team.
All CRE Technology products are delivered with one year warranty, and if necessary we will be happy to come on site for
product commissioning or troubleshooting. The company also provide specific trainings on our products and software.

Technical Support: +33 492 38 86 86 (office hours: 8.30AM-12.30AM / 2PM-6PM GMT+1)

Mail: support@cretechnology.com

Skype: support-cretechnology.com

i
INFORMATION
You can download the up-to-date version of this documentation and different other documentations on our web-
site: www.cretechnology.com

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 2
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

TECHNICAL DOCUMENTATION HISTORY

DATE VERSION COMMENTS


Nov. 2012 A Initial version.
Oct. 2016 B Addition of GENSYS COMPACT and optic fiber information.
May. 2018 C New product design (GENSYS COMPACT & GENSYS COMPACT CORE).
Oct. 2019 D Modification EDS-208A,connection with I4Gen and EDS 280A,modification (p.12) of BSD 2.0 by EC350.
Feb. 2020 E Deletion of chapter «Optic Fiber - Multiple CAN Network (different baud rates).
April 2020 F Modification on optic fiber chapter. Addition of 3G/4G WIFI modem chapter.
Nov. 2020 G Modification on 3G/4G WIFI modem chapter.
Feb. 2022 H Modification of the visuals of the COMPACT range products.

NOTE

i Read this entire manual and all other publications pertaining to the work to be performed before installing,
operating, or servicing this equipment. Apply all plant and safety instructions and precautions. Failure to follow
instructions can cause personal injury and/or property damage.

Contact your CRE TECHNOLOGY distributor for course training.

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 3

HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
RANGE OF WIRING HARNESS

REFERENCES OVERVIEW
A53W1 (3 meters long)
ETHERNET
CROSS CABLE CAT 5

A40W2
CAN, RS485

A40W3
CAN, RS485

A40W4
CAN, RS485

A40W5
CAN

A40W8
CAN, RS485

I-2533CS-60
OPTICAL FIBER CONVERTER Single mode SC
Maximum length: 60 kms

EDS-208A
Ethernet Switch

RUT240
3G/4G WIFI Modem

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 4
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

WIRES
2 – WHITE-BLUE STRIPE = CAN L

7 – BLUE-WHITE STRIPE = CAN H

3 – WHITE-GREEN STRIPE = CAN GND

4 – GREEN-WHITE STRIPE= RS485 GND

5 – WHITE-ORANGE STRIPE= RS485 Rx

6 – ORANGE-WHITE STRIPE= RS485 Tx

WIRING HARNESS FOR COMPACT PLATFORM


COMPACT PRODUCTS → PC (ETHERNET)

A53W1 (Ethernet) CROSS CABLE CAT 5

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
5
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
GENSYS COMPACT → GENSYS COMPACT (CAN Bus)

* 120Ω internal end line resistor activated by * 120Ω internal end line resistor
shunt between CAN H and RES activated by shunt between
CAN H and RES

GENSYS COMPACT → GENSYS COMPACT → MASTER COMPACT →... (CAN Bus)

A40W4 A40W4

* 120Ω internal end line * 120Ω internal end line


resistor activated by shunt resistor activated by shunt
between CAN H and RES between CAN H and RES

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 6
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

COMPACT PLATFORM → REMOTE I/O (CAN Open)

Shield- Drain

GENYS COMPACT
CAN 2

CONNECTION WITH I4Gen AND EDS-280A

I4Gen
A53W1
A53W1
EDS-208A
Ethernet Switch
A53W1

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
7
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
WIRING HARNESS FOR GENSYS 2.0

GENSYS 2.0 → PC (Ethernet)

A53W1 (Ethernet) CROSS CABLE CAT 5

GENSYS 2.0 → GENSYS 2.0 (CAN Bus)

Enable 120Ω
termination resistor

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 8
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

GENSYS 2.0 → GENSYS 2.0 → GENSYS 2.0 → ... (CAN Bus)

120 Ω resistor integrated =


No need to activate the GENSYS 2.0 termination

How many cables do you need?


REFERENCES REQUIRED QUANTITY COMMENTS
A40W3 Total number of GENSYS 2.0 & MASTER 2.0 units - 2
A40W4 Total number of GENSYS 2.0 & MASTER 2.0 units - 3
A40W2 2 One to each end of the CAN Bus

GENSYS 2.0 → GENSYS 2.0 → MASTER 2.0 → (CAN Bus)

120Ω resistor integrated =


No need to activate the GENSYS 2.0/MASTER 2.0 termination

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
9
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
GENSYS 2.0 → REMOTE I/O (CAN Open)

120Ω resistor integrated =


No need to activate the GENSYS 2.0 termination

GENSYS 2.0 CORE → RDM 2.0

Ethernet
(COM4)

A53W1 (Ethernet) CROSS CABLE CAT 5

GENSYS 2.0 CORE → i4Gen

A53W1 (Ethernet) CROSS CABLE CAT 5

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 10
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

CONNECTION WITH OPTIC FIBER

OPTIC FIBER MANAGEMENT

OPTIC FIBER CONVERTOR SINGLEMODE SC. REF : I-2533CS-60 ( MAX LENGHT : 60 KMS)

OPTIC FIBER - Single CAN Network

OPTIC FIBER

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
11
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
CONNECTION WITH 3G/4G WIFI MODEM

MOBILE NETWORK 3G/4G MANAGEMENT

3G/4G router modem : P/N : RUT240X


(The « x » number will change regarding the world region, please check with your CRE TECHNOLOGY contact).

< OR >
3G/4G 3G/4G
MODEM MODEM
RUT240X RUT240X

ETHERNET WIFI
CABLE CONNECTION

I4GEN

AMF COMPACT

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com 12
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
HARNESS AND PERIPHERICAL
UNITS INFORMATION

CONNECTION WITH EC 350

GENSYS (2.0 or COMPACT) → EC 350

WAN (Internet)
or GSM/GPRS (carte SIM)

MODBUS RTU or MODBUS TCP

A40W4 (RS485) for GENSYS 2.0 only

CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE
Phone: + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com
13
HARNESS_PERIPHERICAL_DOCUMENTATION_TECH-SALES DOCUMENTATION_EN_H2022
EXPERT IN GENERATOR solutionS

www.cretechnology.com

www.cretechnology.com
PARALLELING SOLUTIONS_EN_A2017

You might also like