Data sheet for SINAMICS Control Unit CU250S-2 PN

Ordering data
6SL3246-0BA22-1FA0

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Electrical data Ambient conditions

Operating voltage via Ambient temperature

The Power Module DC 24 V Operation -10 ... 50 °C (14 ... 122 °F)

External power supply DC 20 ... 29 V Storage -40 ... 70 °C (-40 ... 158 °F)

Max. power consumption 2.00 A Relative humidity

Power loss 12.00 W Max. operation 95 %

Inputs/ outputs Communication

Standard digital inputs Communication PROFINET

Number 15 Closed-loop control techniques


Switching level: 0→1 11 V V/f linear / square-law / parameterizable Yes

Switching level: 1→0 5V V/f with flux current control (FCC) Yes

Fail-safe digital inputs V/f ECO linear / square-law Yes

Number 3 (Use of 2 × DI Standard) Sensorless vector control Yes

Vector control, with sensor Yes


Digital outputs
Encoderless torque control Yes
Number as relay changeover contact 2
Torque control, with encoder Yes

Output (resistive load) DC 30 V, 1 A Standards


Compliance with standards
UL, cUL, CE, C-Tick
(RCM)
Output (resistive load) DC 30 V, 1 A CE marking

Analog/ digital inputs Low-voltage directive 2006/95/EC

Number 2 (Differential input) Mechanical data


Analog outputs Degree of protection IP20

Number Net weight 0.61 kg


2 (Non-isolated output)
Width 73.0 mm
Connections
Height 199.0 mm
Signal cable
Depth 67.0 mm
Conductor cross-section 0.05 ... 1.50 mm² (30 ... 16 AWG)

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.
Page 1 of 1 Generated Wed Jun 01 14:24:45 CEST 2016