Professional Documents
Culture Documents
Choose Olex-Flexs™ – the complete solution for all your WHY NEXANS OLEX?
No Cutting Charges
flexible cable needs. We Bring Energy to Australians
Free cut to length A proud history of over 75 years,
service to meet your manufacturing quality cables for the
Easy to Bend.
design specifications Australian market and conditions.
Easy to Install.
Reliable Project
manufacturing processes that have
Turnaround
achieved the following accreditations:
Stock available to meet
project turnarounds ISO 9001:2008
without delay ISO 14000:2004
OHSAS 18001:2007
Technical Excellence
Best-in-class technical support and
services. Our highly experienced
and knowledgeable technical team
continue to deliver exceptional
solutions to unique problems.
Page 1 Page 2
COMPLETE FLEXIBLE ALSECURE® Fire Performance
SOLUTIONS FOR
FEATURES
Operating temperature 90ºC and 110ºC, passed WS52W
fire test in accordance with AS/NZS 3013
BUILDING AND
Conductor range up to 630mm2 for Single Core and
300mm2 for Multicore
Maintains circuit integrity for essential services when under fire
INDUSTRIAL
Low Smoke Zero Halogen sheath for reduced environmental
impact, particularly under fire conditions
SUITABLE FOR
FEATURES FEATURES
Operating temperature 110ºC meeting AS/NZS 5000.1 Operating temperature 90ºC meeting AS/NZS 5000.1
AS/NZS 1995 and AS/NZS 4507 RHE (Power) and AS/NZS 1995 (Welding)
Conductor range up to 630mm2 for Single Core Conductor range up to 630mm2 for Single Core
and 300mm² for Multicore and 300mm2 for Multicore
Flexible power cable for variety of building Flexible power cable for variety of building
and industrial applications and industrial applications
Low Smoke Zero Halogen sheath for reduced environmental
impact, particularly under fire conditions SUITABLE FOR
FEATURES FEATURES
Operating temperature 90ºC* meeting AS/NZS 3191, AS/NZS 3012 Operating temperature 90ºC meeting AS/NZS 5000.1
Available in Ordinary and Heavy Duty flexible cords for building, Conductor range up to 300mm2 for Multicore
industrial and manufacturing applications Flexible power cables designed to deliver better EMC
Conductor range in Multicore comes in wide range (Electro Magnetic Compatibility) performance, via 100%
of sizes (For more details, refer to product page) coverage copper tape compared to braided cable
Manufactured in Australia Manufactured in Australia
PVC Best Practice and Green Star rating certified. PVC Best Practice and Green Star Rating Certified
ENVIROLEX
®
OLEX-FLEXS ™
110ºC
of wires diameter
mm2 mm mm kg/100m
10 0.21 8.6 16 BZHX01AA001CXNA
16 0.21 9.8 23 BZHX02AA001CXNA
25 0.21 11.3 31 BZHX03AA001CXNA
35 0.21 12.5 40 BZHX04AA001CXNA
Voltage Rating 50 0.31 14.3 56 BZHX05AA001CXNA
0.6/1 kv
70 0.31 16.2 75 BZHX06AA001CXNA
95 0.31 18.1 98 BZHX07AA001CXNA
Hospital
120 0.51 20.4 113 BZHE87AA001CXNA
150 0.51 22.5 151 BZHE88AA001CXNA
185 0.51 24.8 182 BZHE89AA001CXNA
Construction 240 0.51 27.9 236 BZHE90AA001CXNA
300 0.51 30.8 295 BZHE91AA001CXNA
Single and Multicore flexible 400 0.51 34.7 382 BZHE92AA001CXNA
copper conductor (Class 5 & 6) 500 0.51 40.0 483 BZHE93AA001CXNA
630 0.51 44.6 635 BZHE94AA001CXNA
X-110 (XLPE) insulated
HFS-110-TP sheathed Note: Also available in green/yellow earth between 10mm2-120mm2.
Cl
(Low Smoke Zero Halogen) Br
Fl
It can incapacitate NEW Multicore
individuals and firemen Emergency exits Public high
traffic areas
Standards Nominal
Fire Nominal
Low Nominal Sheath
Corrosion Electro magnetic
Diameter
Approx.mass
Nominal OverallHalogen Product codeHigh
Operating Flam
conductor area Insulation Thickness Thickness interference
during evacuation with AS/NZS 5000.1
resistant
mm2
smoke
mm
resistant
mm mm
free
kg/100m
temp 90°C flexibility retard
ALSECURE
circuit integrity
®
ALSECURE
MICA 110°C
Alsecure® Fire Rated range of cables are designed to preserve
circuit integrity of essential services and electrical equipment
during fire. Alsecure® INFIT Ceramifiable 90ºC is a unique
Flexible Copper
polymer technology that transforms the cable from a flexible Low Smoke Zero
Conductor
insulation into a ceramic barrier during fire. Alsecure® Plus Halogen Material
For ease of handling
Non-toxic emissions in the event
110°, is a MICA Tape layer that acts as protective barrier and installation
of a fire and contributes to the
during fire. These cables meet the WS52W fire test in green star rating of your project
110ºC
110ºC during fire? Easy to strip. conductor
area
insulation
thickness
thickness overall
diameter
radius during
installation
tension code
No hassle. mm2
10
mm
0.7
mm
1.4
mm
8.9
kg/100m
18
mm
40
kN
0.22 PFLX01AA001JBNA
16 0.8 1.4 10.1 24 61 0.34 PFLX02AA001JBNA
25 0.9 1.4 11.6 34 70 0.53 PFLX03AA001JBNA
ALSECURE Voltage Rating 35 0.9 1.4 13.5 44 81 0.72 PFLX04AA001JBNA
Cl92
CERAMIFIABLE
0.6/1 kv
50 1.0 1.4 15.3 63 Br 1.08 PFLX05AA001JBNA
70 1.1 1.4 17.2 82 Fl
103 1.50 PFLX06AA001JBNA
90°C 95 1.1 1.6 19.3 110 116 2.00 PFLX07AA001JBNA
120 1.2 1.6 21.6 134 130 2.50 PFLE87AA001JBNA
Fire Low Corrosion Electro magnetic Halogen Operating High Flame
150 1.4 1.6 23.5 162 141 3.10 PFLE88AA001JBNA
resistant smoke 1.8 resistant interference free temp
3.80 90°C flexibility retardant
Construction 185 1.6 26.2 196 236 PFLE89AA001JBNA
A cable temperature 240 1.7 1.8 29.1 254 262 5.10 PFLE90AA001JBNA
Single and Multicore flexible 300 1.8 1.8 31.8 309 286 6.20 PFLE91AA001JBNA
rating has no direct copper conductor (Class 5 & 6) 400 2.0 2.0 35.9 396 323 8.10 PFLE92AA001JBNA
Cl
relationship to its X-HF-110 Insulated, 500
630Fl
Br
2.2
2.4
2.2
2.2
40.8
45.0
510
646
367
405
10.60
13.70
PFLE93AA001JBNA
PFLE94AA001JBNA
HFS-110-TP Sheathed
performance during fire. to AS/NZS 5000.1, Multicore
110°C, WS52W Fire Halogen Low Operating Flame High
Alsecure Ceramifiable 90ºC
® free conductor Nominal
Nominal smoke insulation
tempNominal
110°C sheath
retardant flexibilityApprox. mass
Nominal overall Product
Rated to AS/NZS 3013
area thickness thickness diameter code
cables were tested up to 1050°C in
mm2 mm mm mm kg/100m
accordance with Fire Test WS52W
requirement and they passed the two Standards 2C+E
Cl
2.5 0.7 1.8 14.2 27.0 PDGP07AA002JBNA
hour fire test. Br 4C+E
AS/NZS 3013 Fl
10.0 0.7 1.8 21.1 79.7 PDGX01AA004JBAA
Hence they will perform the same AS/NZS 5001.1 110.0 PDGX02AA004JBAA
16.0 0.8 1.8 23.9
as 110ºC to preserve circuit integrity AS/NZS 4507 RHE Halogen
25.0 Operating
1.0 Flame
1.8 27.7 174.9 PDGX03AA004JBAA
during fire. free
35.0 temp
1.0 90°C retardant
1.8 31.5 230.4 PDGX04AA004JBAA
50.0 1.0 2.0 35.9 312.2 PDGX05AA004JBAA
• Specifying 90°C fire rated cable Current Ratings
compared to 110ºC is not only a
Refer to AS/NZS 3008
more cost effective option, reducing table 6, 12 & 15 Cl
your total cost of ownership, but it Br
Fl
does so without compromising Emergency exits Shopping centres Public high
traffic areas
the effectiveness. Halogen Low Operating High Flame Chemical
•C
eramifiable cable construction is free smoke temp 110°C flexibility retardant resistance
developed with a layer of polymer
insulation that is easy to strip and
potentially save you cost as it would
Cl ®
be quicker to install (especially on a
Fl
Br Alsecure INFIT Ceramifiable
project that has a large number of
Multicores where installation can be is made to order as per project
Halogen Low
tedious and time consuming). free smoke requirement and lead time.
Office building Tunnel
Call us to discuss range and design solutions.
Cl
Page 7 Br Page 8
Fl
Convenience
Easy termination TPE Sheathed and
and installation physically tougher
VERSOLEX
than PVC
®
Versolex Single and Multicore power cables are specialised industrial SINGLE CORE 90ºC
cables developed for the demanding Australian market conditions.
This multipurpose flexible cable has been designed for use in commercial,
building, OEM, industrial and mining applications, including switchgear,
welding and submersible (up to 500m). onductor range up
C Manufactured in accordance
The Versolex range delivers excellent electrical and environmental properties, to 400mm2 for Single with Australian Standards
Core cables
including resistance to moisture, chemicals and oils. It is more flexible
and physically tougher than PVC with the configuration of XLPE insulation
90ºC
compared to 110ºC
area of wires diameter mass
mm2 mm mm kg/100m
rated power cables? 10 0.21 8.5 13.9 BDSX01AA001OMNA/HTNA
16 0.21 9.8 20.0 BDSX02AA001OMNA/HTNA
25 0.21 11.3 27.5 BDSX03AA001OMNA/HTNA
35 0.21 12.5 36.7 BDSX04AA001OMNA/HTNA
Voltage Rating 50 0.31 14.3 51.3 BDSX05AA001OMNA/HTNA
70 0.31 16.2 70.7 BDSX06AA001OMNA/HTNA
0.6/1 kv 95
120
0.31
0.51
18.1
20.6
91.7
107.8
BDSX07AA001OMNA/HTNA
BDSE87AA001OMNA/HTNA
150 0.51 22.5 144.2 BDSE88AA001OMNA/BFBE/JBRD
Office building 185 0.51 24.6 174.5 BDSE89AA001OMNA
240 0.51 27.7 227.8 BDSE90AA001OMNA
Construction
300 0.51 31.0 282.4 BDSE91AA001OMNA
Single and Multicore Flexible 400 0.51 35.4 369.1 BDSE92AA001OMNA
Copper Conductor (Class 5 & 6)
For applications that X-90 insulated
10mm2-150mm2 also available in Earth Conductor Green/Yellow. Sheath colour code (represent the last 4
letters): OMNA-Orange, HTNA-Earth G/Y, BFBE-Blue, JBRD-Red . Note: 500-630mm2 – Available on Made to
do not require higher TPE-90 sheathed to Order
AS/NZS 5000.1
operating temperature,
NEW Multicore
Versolex® 90ºC would be
Standards Nominal conductor Nominal insulation Nominal sheath Nominal overall Approximate mass Product code
the best option. Manufacturing Hospitals area thickness thickness diameter (kg/100m)
AS/NZS 5000.1 mm2 mm mm kg/100m
This will potentially save cost of ownership AS/NZS 1995 (Welding) 2C+E (Note: 6.0mm2 is available on Made to Order)
for developers and asset owners whilst 1.5 0.7 1.8 10.3 13.5 PTFR04AA002CXHF
reducing energy cost for end-users. 2.5 0.7 1.8 11.3 17.5 PTFR05AA002CXHF
Additionally, this will also minimise the Current Ratings 4.0 0.7 1.8 11.9 21.0 PTFR06AA002CXHF
impact on the environment and reduce 3C+E (Note: 1.5mm2, 6mm2-35mm2 are available on Made to Order)
Refer to AS/NZS 3008 2.5 0.7 1.8 12.2 20.9 PTFR05AA003CXRJ
CO2 emissions. table 5, 8, 11 & 14 4.0 0.7 1.8 13.0 26.0 PTFR06AA003CXRJ
Applications: Mains/sub-mains and final 4C+E (Note: 70mm2 - 300mm2 are available on Made to Order)
circuits connecting to moving equipment 1.5 0.7 1.8 12.0 18.6 PTFR04AA004CXEM
2.5 0.7 1.8 13.1 24.7 PTFR05AA004CXEM
and electrical appliances. Suitable for all 4.0 0.7 1.8 14.1 31.5 PTFR06AA004CXEM
applications from small equipment 6.0 0.7 1.8 15.2 40.6 PTFR07AA004CXEM
Heavy
to heavy industrial. industrial Industrial
10.0 0.7 1.8 18.5 63.0 PTFX01AA004CXEM
16.0 0.8 1.8 21.4 87.7 PTFX02AA004CXEM
25.0 0.9 1.8 24.7 116.9 PTFX03AA004CXEM
High High
Water Enviromental
Water Oil/fuel/solvent
Enviromental Oil/fuel/solvent
Heat Electromagnetic
Heat Electromagnetic
Operating Acids/bases
Operating Acids/bases
Physical Physi
flexibility immersion
flexibility immersion
exposure exposure
resistant environment
resistant compatibility
environment compatibility
temperature temperature
resistant toughness
resistant toughn
Page 9 Page 10
Symmetrical Full (100%) coverage overlapping PVC Bedding
Split Earth copper tape screen with strong surface for consistent shape
VAROLEX
Design transfer impedance properties for increased
® shielding effectiveness vs braid screens
Flexible
Class 5
VAROLEX
or Class 6
Copper
NOW WITH NEW FLEXIBLE CONDUCTOR
FLEXIBLE 90°C
Conductor
EASY TO TERMINATE & INSTALL for easier
termination
Olex VSD Flexible Cables are specially designed to
deliver better EMC (Electro Magnetic Compatibility) performance
Low Capacitance Increased Earth
than traditional braided cable. With increased shielding Insulation with Conductors for
high voltage reduced grounding Independently
effectiveness, it improves transfer impedance, making it ideal breakdown impedance audited PVC Best
for a variety of applications in manufacturing, tunnels and strength Practice sheath
90ºC
Nominal Nominal insulation Combined earth Nominal Approx. Min. Bend Product code
performance? conductor area thickness size area overall mass Radii(installed)
Varolex® unique cable design incorporates 100% coverage copper tape diameter
screen, symmetrical split earth, increased earth sizes and low capacitance mm2 mm mm2 mm kg/100m mm
1.5 0.7 1.5* 13.5 26 162 FTDR04AA003CXRJ
insulation thus it delivers superior EMC performance through better transfer 2.5 0.7 2.5* 14.6 33 175 FTDR05AA003CXRJ
impedance and shielding effectiveness as shown below. Voltage Rating 4.0 0.7 4.5 16.8 46 202 FTDR06AA003CXRJ
6.0 0.7 4.5 18.7 59 224 FTDR07AA003CXRJ
Note: *Split earth not feasible, therefore a single earth conductor is utilised.
Nexans Olex
Standards
Varolex VSD Varolex design
®
Benefits of Nexans Olex 10-4 Copper Tape copper tape AS/NZS 5000.1
ST PRACTI ST PRACTI
VSD Flexible Cables
BE
CE
BE
CE
Corrugated
ES
ES
MANU
MANU
Steel Aluminium Current Ratings
ABL
ABL
Conduit
FA C C FA C C
Improves handling and installation 10-5 High Water Refer to AS/NZS Oil/fuel/solvent
Enviromental 3008 High
Heat Water
Electromagnetic Enviromental
Operating TURED
Oil/fuel/solvent
Acids/bases Heat T U R E D Electromagnetic
Physical Operating Acids
1 10 100 1.103 1.104 1.105 1.106 1.107 1.108 flexibility immersion exposure resistant flexibility
environment immersion
compatibility exposure
temperature resistant
resistant environment
toughness compatibility temperature resi
The inclusion of PVC bedding and table 14
Nexans quality manufacturing processes
assist in maintaining the circular shape
Screen Performance Shielding Effectiveness ST PRACTI ST PRACTI
of the cable throughout the entire
BE
CE
BE
CE
length for consistent handling by
ES
ES
MANU
MANU
100
ABL
ABL
electrical installers. In addition, Varolex® Steel Corrugated
FA C FA C
TURED C TURED C
95 Conduit Aluminium
VSD Flexibles incorporates a flexible 90 Mains Versolex / ®
Variable Varolex® Motor
copper conductor for fast and easy 85 Nexans Olex Varolex® design power Envirolex® Speed VSD Cable
Varolex VSD
terminating. 80 copper tape supply Flexible Drive
75
Copper Tape
Cable ST PRACTI bl
es Best
Longevity
BE
CE
red Ca
Practice
70
ES
MANU
With high voltage breakdown strength
ABL
65
FA C
tu
T U R E D C ® Flexible Conductors are
Varolex
Ma ac
insulation and P VC Best practice
nuf
60 Steel Wire
sheathing compounds, you can trust
Varolex® VSD cables to continue to
55
50
Armour
currently made to order and will
Aluminium ** T
hese graphs are calculated
perform. 45 Foil using Nexans Olex cable be
es
t Pracstocked
ti in coming months.
40 designs and only appropriate
ce
Call 1300 CABLE to discuss availability.
B
Open Helix Copper to the Nexans Olex cable offer.
35 Copper Tape Wire Braid
30 The use of these graphs without
Nexans Olex permission
1 10 100 1.103 1.104 1.105 1.106 1.107 1.108
is prohibited.
Page 11 Page 12
Convenience
POWERLEX
Easy termination
® and installation
Powerlex® flexible cords and cables are versatile and can be used
POWERLEX 90°C
in a variety of applications including domestic, industrial, and
commercial environments. The range consists of Ordinary Duty and
Heavy Duty cables that have been designed to meet AS/NZS 3191.
Made with PVC insulation and PVC sheath, under PVC Best Practice Available in popular Manufactured in accordance
manufacturing processes and will contribute to your Green Star Multicore sizes with Australian Standards
90ºC
'Flexible Cords'. area
mm2
of wires
mm
diameter
mm kg/100m
2C+E
1.00 0.21 9.0 11.0 EBGR03AA003OGAA
1.50 0.21 9.9 14.0 EBGR04AA003OGAA
2.50 0.21 11.7 21.0 EBGR05AA003OGAA
Voltage Rating
Ordinary Duty
Ordinary duty
250/440V
Nominal conductor Maximum diameter Nominal overall Approx.mass Product code
area of wires diameter
Office building
mm2 mm mm kg/100m
Heavy duty
0.6/1 kv
2C
0.75 0.21 6.2 5.6 CAHR02AA002KKAA
Whether at home or at
0.75 0.21 6.2 5.6 CAHR02AA002GYAA
2C+E
work, Powerlex® flexible Construction
0.75
0.75
0.21
0.21
6.6
6.6
6.5
6.5
EAHR02AA003GYAA
EAHR02AA003KKAA
cords give you flexibility Flexible copper conductors
1.00
1.00
0.21
0.21
6.9
6.9
7.6
7.6
EAHR03AA003GYAA
EAHR03AA003KKAA
without compromising (Class 5),
1.50
1.50
0.31
0.21
8.1
8.1
11.0
11.0
EAHR04AA003OGAA
EAHR04AA003GYAA
performance. PVC V-90 insulated, PVC
sheathed Heavy Duty and
1.50 0.21 8.1 11.0 EAHR04AA003BKAA
Manufacturing 2.50 0.21 9.9 17.0 EAHR05AA003GYAA
Household
Ordinary Duty flexible cords 2.50 0.21 9.9 17.0 EAHR05AA003OGAA
Heavy Duty Powerlex® cables comply 4.00 0.31 11.2 23.0 EAHR06AA003GYAA
Manufactured to PVC 3C+E
with AS/NZS 3012 requirements for
Best Practice Guidelines 1.00 0.21 7.8 9.5 GAHR03AA004GYAA
construction and demolition sites. 1.50 0.21 9.1 13.0 GAHR04AA004GYAA
These cables give you resistance to
corkscrewing (pig-tailing) often seen with Standards Note: *The colour code for the above product (last 4 letters) represent: BKAA-Black, OGAA-Orange, GYAA-
flexible cable that are hard wound after AS/NZS 3191 Grey, KKAA-White.
the job is done. The tough outer sheath
AS/NZS 3012
reduces damage to the cable due to cuts (Heavy Duty range only)
and abrasions during operation.
AS/NZS 60227 ST PRACTI ST PRACTI
BE
CE
BE
CE
(Ordinary Duty range only)
ES
ES
MANU
MANU
ABL
ABL
Tradesmen
Commercial
FA C C FA C
C T U R E D Oil/fuel/solvent
Current Ratings High TURED
Water Enviromental Heat Electromagnetic Operating Acids
flexibility immersion exposure resistant environment compatibility temperature resi
Electrical appliance applications
refer to table 16 of AS/NZS
3008.
ST PRACTI ST PRACTI
Fixed installation wiring
BE
CE
BE
CE
ES
ES
MANU
MANU
applications refer to table
ABL
ABL
10,11,13 and 14 of AS/NZS FA C FA C
3008. TURED C TURED C
ST PRACTI bl
es Best
BE
CE
red Ca
Practice
Page 13 Page 14
ES
MANU
ABL
FA
tu
C
Ma ac
nuf
Trusted by
Australians
for over
75 Years
Nexans Olex is Australia’s leading cable
manufacturer with over 75 years of success in
servicing the Australian markets.
With a long standing reputation and excellence in
delivering world-class cable design, engineering
solutions and manufacturing excellency, Nexans
Olex cables meet and exceed the relevant Australian
and International Standards. With a rich history at
its core, Nexans Olex draws on global parentage
to lead the electrical industry through technical
innovation, quality and industry stewardship.
Nexans Olex specialises in delivering cables and
cabling solutions to major industries including
Building and Construction, Energy Resources,
Infrastructure, Renewable Energy and Electricity
Supply Industry (ESI).
Page 15