You are on page 1of 70

DMS Program

User’s Guide
For Integrated DMS-5 Software
Contents
DMS Program User’s Guide ................................................................................................................................................. 1

View DMS Program .................................................................................................................................................................. 5

Provide Function Overview ........................................................................................................................................ 5

General function ............................................................................................................................................................... 5

Tool ........................................................................................................................................................................................... 6

Machine Function............................................................................................................................................................. 6

Engine Function ................................................................................................................................................................ 7

The Basics ...................................................................................................................................................................................... 8

Program Setup ................................................................................................................................................................... 8

Program installation recommended ............................................................................................................ 8

Communication Connection....................................................................................................................................... 8

Communication Cable .......................................................................................................................................... 8

Communication Preferences ...................................................................................................................................... 9

Support Models Select Model ...................................................................................................................... 10

Program Preferences ................................................................................................................................................... 11

Report .................................................................................................................................................................................. 12

Export .................................................................................................................................................................................. 13

Start................................................................................................................................................................................................ 14

Login ..................................................................................................................................................................................... 14

function Start, Stop, Refresh, Exit ....................................................................................................................... 15

Check the basic information of the machine ................................................................................................ 15

Tool ................................................................................................................................................................................................. 17
Open the graphical log file (Play) ....................................................................................................................... 17

CAN Bus Monitoring(connected with UVIM adapter) ............................................................................. 17

TMS Terminal Status.................................................................................................................................................... 18

Snap Shot .......................................................................................................................................................................... 19

Machinery Diagnostics ........................................................................................................................................................ 21

Monitoring ........................................................................................................................................................................ 21

Graph.................................................................................................................................................................................... 22

Fault Code Information View ................................................................................................................................. 25

Force Operation ............................................................................................................................................................. 25

Fuel Consumption View ............................................................................................................................................ 28

Operation Hours View ................................................................................................................................................ 28

Filter/Oil Info ................................................................................................................................................................... 30

Daily Operation Info View ....................................................................................................................................... 32

Parameter View .............................................................................................................................................................. 33

Backup/Restore .............................................................................................................................................................. 34

ThumWheel Joystick Adjustable sensitivity ................................................................................................... 35

EPOS Update(for controller) ................................................................................................................................... 38

Diagnosis of engine TIER3 ................................................................................................................................................ 41

Fault code .......................................................................................................................................................................... 41

Data Monitoring ............................................................................................................................................................ 44

Run-up test ....................................................................................................................................................................... 46

Test shut-off ..................................................................................................................................................................... 47

Compression test .......................................................................................................................................................... 48


Remote Control .............................................................................................................................................................. 49

Register machine ID .................................................................................................................................................... 49

Software Updates (for ECU) .................................................................................................................................... 51

ECU Info.............................................................................................................................................................................. 51

Diagnosis of engine TIER4 Interim ............................................................................................................................... 53

Fault code .......................................................................................................................................................................... 53

Data Monitoring ............................................................................................................................................................ 54

Run Up Test ...................................................................................................................................................................... 57

Shut-Off Test .................................................................................................................................................................... 57

Input/Output Test ......................................................................................................................................................... 59

EOL ........................................................................................................................................................................................ 61

Software Updates (for ECU) .................................................................................................................................... 61

ECU Info.............................................................................................................................................................................. 62

Trouble Shooting .................................................................................................................................................................... 64


View DMS Program

Provide Function Overview

The Doosan Excavators / Wheel Loaders Monitoring Program (aka DMS) e-EPOS controller is
mounted on excavator Or VCU controller mounted on the wheel loader, and the engine controller
provides the following function using the communication between the (ECU) and an IBM, -In
function is a function to function as an engine for the device to distinguish and, Each feature is
configured to automatically screen depending on the connected model.
The main functions can be selected with the Top navigator and Left navigator. The selected
function is displayed on the main display screen, You can check the current status in the state bar.

General function

Function Description
Report You can report key information, such as the main sensor
data and uptime information of the machine.
Pleaes refer to the report function.
Export You can save the data identified in each function.
Pleaes refer to the Export function.
Select Machine You can choose to connect to the machine or engine
model. Communication preferences are set automatically.
Pleaes refer to the Select Machine function.
Property You can set the language of the application or output
units. Pleaes refer to the Property function.
Start You can begin to communicate with the machine. Start
the communication about the features that are currently
running on the main screen.
Stop You can stop the communication with the machine. Stop
the communication of the features that are currently
running on the main screen.
Refresh Refresh the current running function for the main screen.

Close Quit the program.

Tool

Function Description
Load Graph Log You can play the graph data storage.
File Pleaes refer to the Load Graph Log File function.
Manual View You can view the program help.

CAN Bus You can monitor the communication data of the CAN
Monitoring bus is the machine.
Pleaes refer to the CAN Bus Monitoring function.
TMS Terminal You can check the status of the TMS Terminal.
Status Pleaes refer to the TMS Terminal Status function.
Sanp Shot You can view the saved engine monitoring data.
Pleaes refer to the Sanp Shop function.

Machine Function

Function Description
Machine Info You can see the basic information, such as machine
model, serial number and version of the program of the
machine.
Monitoring It shows real-time information of the key sensors of the
machine to List or Gauge Panel form.
Graph You can see the real-time information on the important
sensor of the machine in graphic form.
Force Operation The output of the machine controller can be artificially
simulated by driving force, build a variety.
Parameter You can view or modify the machine control parameters.
Pleaes refer to the Parameter function.
Fuel Consum You can check or reset the fuel used information from
the machine.
Operation Hours You can check or reset the period-specific information in
the machine uptime.
Daily Oper. Info You can check or reset the daily operating information
of the machine.
Filter/Oil Info Check the filter / oil change intervals and the operating
time of the machine or modified, can be reset.
Fault Info You can check or reset the current faults and past faults
history of the machine.
Backup/Restore You can back up or restore the information stored in the
machine controller.
Software Update You can change the firmware of the machine controller
to the desired version.

Engine Function

Function Descriptiom
ECU Information The basic information such as the model name, serial
number and version of the program of the engine.
Monitoring It shows the important sensor and services data of the
engine to List or graph form. You can store data over a
snap shot function.
Snap Shot You can play the data through a snap shot function.

Fault Code You can check or reset the current faults and past faults
of the engine.
RunUp Test It is possible to test the performance of individual
cylinders of the engine.
ShutOff Test To switch off the injection of the selected cylinder
engine can be a shutoff test.
Input/Output It is possible to control the engine actuator test the
Control actuator status.
EOL You can change the PRV Valve and Ash and DPF.

Reprogramming Firmware can be changed to any version of the engine


controller.
The Basics

Program Setup

You have to run SETUP.EXE program to automatically install the DMS. Please contact the program
manager if the monitor, the screen of the graph outputs, such as would normally appear when
you run the program after installation is complete.

Program installation recommended

To run the DMS program at a built-in over Windows XP OS IBM PC-compatible computer is
required.

 More than Memory 2G


 PC operating system, and then you have a USB 2.0 or 3.0 port:
 Windows 8, Windows 7, Windows Vista or Windows XP Home or Professional(Service
Pack 3)
 more than Microsoft DotNet Framework 4.0

Note: You must use a separate Adapter is certified Adapter provided by the company.
Communication Connection

In order to perform communication with an external PC and the machine requires a separate
communications cables. Communication cables must be connected to a COM port or a separate
Kit Adpater the inspection connector mounted on the machine with your PC.
Note) When removal of the communication cable is performed in the state, please disconnect the
power source of the excavator.

Communication Cable

Equipment that can be connected to the diagnostic port 3Pin, 14Pin have a cable, General RS232
cable, you can connect a USB type and the PC. Also, to connect to the engine controller can be
configured as a separate UVIM Adapter.

3 Pin Cable. 3 Pin cable diagnostics port, you can connect using the Equipment consists of 3 Pin.
14 Pin Cable. 14 Pin cable diagnostics port, you can connect using the Equipment consists of 14
Pin.

UVIM Apdater. UVIM ADpater connections at the same time by using the equipment and the
engine controller, you can check the machine or engine information. If you use the adapter, you
can UVIM than the PC connection via USB.

RS232 Cable. You can use the RS232 port and RS232 Cable to connect your PC. Depending on
the status of the PC RS232 to USB cable is required.

WARNING: If you use an unauthorized cable may not be normal communication is not
performed.

Communication Preferences

To communicate with the machine and engine Select a model of machine or engine during the
start of the program, Select the desired communication Port will be automatically communication
preferences. If you click the Apply button to start the communication with the machine.

Note: Solar, DL Model is Baudrate 9600, DX Model is 57600, and others have excluded the engine
and set to 115200 by default.
Support Models Select Model

Select Model Support Model


Select Model Support Model
Solar Model Solar
DX110LCR, DX140W, DX140WE, DX140LCR, DX140LC,
DX180LC, DX170W, DX190W, DX190WA, DX235LCR,
DX220LC, DX220LCY, DX225LC, DX225LL, DX210W,
DX255LCY, DX255LC, DX300LCY, DX300LC, DX340LC,
DX350LC, DX350LCY, DX380LC, DX700LC, DX420LC,
DX Model
DX480LC, DX480LCA, DX420LCA, DX420LCA, DX340LCA,
DX300LCA, DX480LCY, DX420LCY, DX380LCY, DX225LCY,
DX340LCY, DX150LCY, DX225LCA, DX210, DX225LNC.
DX225NLCA, DX260LCA, DX520LC, DX300LL, DX140W
ACE, DX190WA, DX210WA
DX140LC-3, DX140LCR-3, DX140W-3, DX170W-3,
DX180LC-3, DX190W-3
U Model
DX210W-3, DX210LCR-3, DX225LC-3, DX255LC-3,
DX300LC-3, DX340LC-3,
DX350LC-3, DX350LCY-3, DX380LC-3, DX420LC-3,
DX490LC-3, DX700LC-3
DX140LC-5, DX140LCR-5, DX180LC-5, DX225LC-5,
DX235NLC-5, DX235LCR-5
DX255LC-5, DX300LC-5, DX340LC-5, DX380LC-5,
DX420LC-5, DX490LC-5, DX530LC-5, DX140W-5,
V Model
DX170W-5, DX190W-5, DX210W-5, DX190WA,
DX210WA, DX225NLCA, DX260LCA, V05, DX140W,
DX220LCA, DX480LCA, DX420LCA, DX420LCA,
DX340LCA, DX300LCA
DL Model DL
DL200-3, DL250-3, DL300-3, DL300-3 (eMCV), DL350-3,
H Model DL350-3 (eMCV), DL400-3, DL400-3 (eMCV), DL450-3,
DL450-3 (eMCV), DL550-3, DL550-3 (eMCV)
DL200-5, DL250-5, DL300-5, DL300-5 (eMCV), DL350-5,
K Model DL350-5 (eMCV), DL400-5, DL400-5 (eMCV), DL450-5,
DL450-5 (eMCV), DL550-5, DL550-5 (eMCV)
DX120-9C, DX220LC-9C, DX340LC-9C, DX380LC-9C,
C Model
DX420LC-9C, DX500LC-9C

Note: If the model is not identified in the list included by default in the model of the machine -3
U, H Model select, and if -5 is included, select V, K, C Model. Please contact us for additional
models are not identified as a Program Coordinator.

Communication state check. The right of the State Bar LED is lit, the LED during transmission /
reception, you can check the communication status.

Program Preferences

You can set the default language, units of the program. If the language change will apply when

you restart the program.

Open the program Preferences items. Click Home> Settings item in the Navigator at the top of the

screen. ( )
The type of configuration data
 Setting Language (Korean, English, Chinese, Russian, Spanish, Portuguese, French, Dutch)
 Skin Settings program : Dark, Mac, Windows 7, Caramel, Whiteprint, Metropolis Dark,
Metropolis
 unit setting
 Pressure, Temperature, Volume, Fuel consumption, Speed, Flow rate

Setting Language. Home> Go to Settings, and then restarted when you apply the setting item
and then select the language of the program.

Skin Setting program. Home> Go to Settings, and then choose the desired skin can be applied
to the program Program Skin entries.

Unit setting. Home> Go to Settings, and then can be applied to select the desired unit of a unit
setting item.

Report

You can gather the main data of the machine and save the form as a report. You can share via E-
mail or any other sharing programs, depending on your PC environment.

Open Report Item. At the top of the screen Navigator Home> Click the report item. ( )
Export

You can save a file type that is currently done by collecting data. You can share via E-mail or any
other sharing programs, depending on your PC environment.

Open export items. Home > Click the Export item at the top of the screen. ( )
Start

Login

Login of the machine is divided into AD authentication system and installing H / W based

Registry Key registration method of the Doosan Group. Registry Key registration is available the

receiving grants Key generated based on the information in the program is installed H / W.
function Start, Stop, Refresh, Exit

By default, the start of communication via the start button, when performing the functions of the
program, and, during the stop, click Cancel. Stop automatically runs when you switch on each

screen.

Start Communication. In the Navigator, click the Start button at the top of the screen. When you
click the Start button, stop button is activated, the Start button is disabled.

Stop Communication. Click the Stop button in the Navigator at the top of the screen. If you click

the Stop button the start button is activated, the Stop button is disabled.

Refresh. Click the Refresh button in the Navigator at the top of the screen. Refresh is used for

one-off requests, the periodic transmission function will be disabled.

Check the basic information of the machine

The program will display the basic information of the normal equipment and communication
equipment are made, the Main Screen. The machine information can be checked through the
mechanical information function.
Open the machine infomation. Machine Information > In the Navigator at the top of the screen,
click the Machine Information topic. ( )

The type of data provided


 Machine Information : Model name, serial number, you can check the program version
information.
 Serial Number: You can view and modify the unique serial number that identifies your
machine.
Click Modify button, and then enter the serial number

 Machine Condition: The total running time of the machine, you can check the current
failure count.
Tool

Open the graphical log file (Play)

You can play the stored graphical log file. And analyze the data for the entire trend analysis, and
the specific conditions of the data stored by the graph view..

Open graph of log file entries. Screen Tools at the top of the Navigator > Click on the graph log
file open items ().

Check the values in the graph. (Action: Mouse Over) If the Mouse Over a graph screen graph
of the data values in Mouse Cursor time are displayed on the screen.

CAN Bus Monitoring(connected with UVIM adapter)

When performing a communication through a machine controller and UVIM Adapter, you can
monitor the signal of the CAN Bus equipment. If it is connected via the CAN device controller and
UVIM Adpater, you can use the feature.
CAN Bus Monitoring Open Items. Screen Tools at the top of the Navigator > Click on the CAN
Bus Monitoring item ().

Transmit Message. You can send your ID and Data via the CAN Bus. Enter the ID and Data and
click the Send button to send the data to the CAN Bus.

Data Logging. If you check the log file, you can save data to a file of the CAN Bus.

Send Data. Make the desired CAN Message can be sent to the control unit.

TMS Terminal Status

To monitor the state of TMS Terminal attached to the device.

Opening the TMS Terminal Status Item. Screen Tools at the top of the Navigator > Click TMS
Terminal Status item
Security release. You can turn off the machine Lock feature of the TMS Terminal.

Warning: Security release function can only be used by authorized users

Snap Shot

You can play back the stored Engine Monitoring Data.

Open topic Snap Shot. Screen Tools at the top of the Navigator > Click the Snap Shot item.

Open. You can call up the saved Engine Monitoring Data. (*.snap)
Graph. You can view the imported Data in Graph.

Start. Data stored can be played in chronological order.

X2 Start. You can play back the stored Data 2-speed roads.

Pause. You can temporarily stop playback.

Stop. Stops playback.


Machinery Diagnostics

Monitoring

To read various data associated with the machine in real time. The data show a List form, by
default, you can choose an item to select the data you want to see. After selecting the desired
data, you can perform the communication with the device via the Start / Stop button in the Top
Navigator.
See the data types can be found in List, Graph, Gauge Control.
The type of data provided
 Sensor data : Data of the frequency and analog sensors
 Engine speed (rpm), Battery voltage (V), FRONT PUMP Pressure / REAR PUMP etc.
 Digital input / output state: Data of ON / OFF type sensors, such as various switches, the
control state
 Start Switch, Alternator, etc.

Open machinery monitoring. Machine information at the top of the screen or the left Navigator
> Click the Monitoring item. ( )

Open Graph View. Machine information at the top of the screen or the left Navigator > Click the
Graph item. Or click on the graph view in the Main Screen.
Show controls. Click the View Control in the Main Screen.

Select Monitoring Group. So you can select the items you want to monitor to switch to List View
screen. When you select the desired data is updated value of the selected data. This button is
activated only view control.

Communication period setting. It sets the period of the data received from the machine.
Transmission cycle can be set up to 10msec ~ 2550msec. However, this feature is not supported
for models this item will not be visible.

Graph

Can identify a variety of data relating to the machine in real time, The data show the Graph type
by default, select the data selection (monitor screen), you can select the data you want to see.
After selecting the desired data, you can perform the communication with the device via the Start
/ Stop button in the Top Navigator.
The type of data provided
 Sensor Data : Data of the frequency and analog sensors
 Engine Speed(rpm), Battery voltage (V), FRONT PUMP Pressure / REAR PUMP
pressure, etc.
 Digital input / output state: Data of ON / OFF type sensors, such as various switches, the
control state
 Start switches, alternators, etc.

Note: If you have a long time to collect data stored in a file via the Export function, open the
graphical log file (play) it is effective analysis functions.

Open View Machines graph. Machine information at the top of the screen or the left Navigator
> Click the Graph item or mechanical information. ( ) > Click on the button in the graph view
monitoring item.

Select Monitoring Group. If you click the Select button to switch to monitoring data List
selection Page. Select the desired data and press the Graph View icon to switch to graph view
screen.

View individual graph. You can view the data that is being monitored as a separate graph. If a
check function is activated and deactivated when the check revocation.

Logging File Save. Save a file for the data being monitored. If the left Navigator > Click the
Export item, function is activated. When the user activates the pop-up function for saving a file is
output. You can save the file to the desired name in the desired position. The files are saved as
* .csv form. Data is stored at the top of the Navigator tool > Open the log file can be played with
graph functions. You can also edit the desired shape through the editable program for saved files.
(Ex: Micosoft Excel)

Communication period setting. It sets the period of the data received from the machine.
Transmission cycle can be set up to 10msec ~ 2550msec. However, this feature is not supported
for models this item will not be visible.

View selected Y-axis data. The check items for viewing the Y-axis value of the data. When you
select the Check Box of the data that you want to see Y Y-axis values of the graph axes it is
added. In addition, so that the thickness of the thick graph makes it easier to distinguish between
the selected data.

Key+Mouse Functions. When you click this item, you can see a description of the functions that
can be performed by combining the operations of the Key and Mouse, such as zoom in / out /
move the graph pop-up Screen.

Providing a key operation type

Division Action
shift + LeftMouse Drag Zoom into Selection.
shift + Alt + LeftMouse Drag Zoom into proportional selection.
shift + LeftClick Zoom in around point.
shift + UpArrow Zoom in around middle of plot area.
shift + DownArrow Zoom out around middle of plot area.
shift + MouseWheel Zoom in/Zoom out.
shift + RightClick Undo.
shift + Baclspace Reset.
Ctrl + LeftMouseDrag Pan.
Ctrl + LeftArrow Pan left.
Ctrl + RightArrow Pan right.
Ctrl + UPArrow Pan Up.
Ctrl + DownArrow Pan down.
Ctrl + RightClick Undo.
Ctrl + Backspace Reset.
Check the values in the graph. (Action: Mouse Over) If the Mouse Over a graph screen graph
of the data values in Mouse Cursor time are displayed on the screen.

Fault Code Information View

You can read about current / past information relating to machine malfunction. (Fault Code, failure
information and actions to take (Manual) and time of occurrence of past failures)

The type of data provided


 Fault: Up to 30 current fault information generated
 fault code, fault information, Manual
 Past failure: Up to 31 past caused the failure information
 Code number by failure, failure codes, failure information, fault occurrence time,
Manual

Open Fault Information. Machine information at the top of the screen or the left Navigator >
Click fault information items ().

Delete past failure history. Clicking the past fault history Delete button you can delete or
initialize the past failure information is stored.

Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.

Force Operation

The output of the machine control is a function to forcibly drive. It can be artificially achieved by
the implementation in the actual system, difficult by this function. Activates the driving force to
the driving force to the selected items, It is divided into two and applying the actual value, If the
driving force function is enabled (ON) of afterwards, it can not be applied to the driving force
value.

The type of data provided


 Proportional pressure reducing valve control output (Pumps, fans, flow control):
0~1000mA
 Solenoid valve output: Step-up, high-speed driving, turning priority, reverse, post heating
Relay (ON/OFF output)
 Engine control output (Mechanical): Standard Mode, AUTO IDLE, OVERHEATING, WORK
MODE (W) Signal output

Note: The type of data provided may be different for each model.

Open ForceOperation entry. Machine information at the top of the screen or the left Navigator >
Click the ForceOperation entry ().

Select the ForceOperation entry. Please check all the items, select the check box at the bottom
of each item or selection.
Off the ForceOperation entry. Turn off the Select or deselect the check box of each item at the
bottom.
ON the ForceOperation choices. Clicking on the selection ForceOperation ON button to turn ON
the ForceOperation for the selected item.

Off the ForceOperation choices. Clicking off the selection ForceOperation off button to turn off
the ForceOperation for the selected item.
ForceOperation value input. ForceOperation to specify the number in the value field of the
application screen. Or to adjust the value of the control bar of the applicable value to the desired
value.

ForceOperation apply. If you click the Apply icon of each item will ForceOperation the machine
to the value entered in the applicable value.

Combining a pop-up screen to the Main screen. A pop-up screen with the mouse to drag an
icon from which you can select the desired location on the main screen will be activated ( ).The
pop-up screen When you release the mouse in the desired position will be joined to the Main
screen.

Warning: ForceOperation has got the power to drive a mechanical force, only gateun users can
use the associated privileges. Users who do not have the right to provide its functionality.

Warning: When you exit the test ForceOperation home within the program, information
machines, tools > Click the Stop button or click the selection Forceoperation OFF button must be
stopped Forceoperation Because so should the machine is working properly. Or cycle the start-up
of the machine gun and restarts the action.
Fuel Consumption View

You can check the fuel consumption using the machine in each mode, which provides machinery.
You can reset the fuel consumption is stored in the machine.

Open the Fuel Consumption view. Machine information at the top of the screen or the left
Navigator > Click on the fuel Consumption items.

Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection.

Off initialization entry. Turn off the Select or deselect the check box of each item at the bottom.

Initialization selection. When you click the Reset button to reset the usage information for the
selected item.

Warning: Fuel consumption initialization function is available only to relevant authorized users
gateun. Users who do not have the right to provide its functionality.

Operation Hours View

You can check the uptime information for the items specified in the mode-specific or hydraulic oil
temperature, coolant temperature, etc. Group of machines.temperature, coolant temperature, etc.
Group of machines. Uptime is the time in each mode, except for chonggadong can optionally be
reset.
Open the Operation hours view. Machine information at the top of the screen or the left
Navigator > Operation hours view, click the item.

The type of data provided


 Total Uptime
 Operation Mode uptime
 Attachment used by uptime
 Work/Travel mode (wheel type) : Work/Travel
 Travel mode (Crawler type) : I speed/ 2speed
 Hydraulic oil temperature distribution (℃) : 30 Below /31~50/51~75/76~85/86~95/96
More than
 Cooling water temperature distribution (℃) : 40 Below /41~60/61~85/86~95/96~105/106
More than
 Engine Speed(rpm)/(Torque)/Torque-Speed Zone
 Front / rear pump load

Note: The type of data that can be provided by different models.


Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection. Only the selected item, you can check the information from the List on the right.

Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
The unchecked item can not verify the information in the List on the right.
Initialization selection. When you click the Reset button to reset the usage information for the
selected item.

warning: Uptime initialization function is available only to relevant gateun user rights. Users who
do not have the right to provide its functionality.

View a group-specific data Bar Char. (Action: Mouse Click) If you click the Group name is the
data values of the selected group it will be displayed on the screen at the bottom of a Bar Chart.

Filter/Oil Info

You can check the machine's filter / oil change intervals and the use of time. In case replace the
filter / oil set a new replacement cycle, or you can reset the usage time.

Open Filter / oil information items. Machine information at the top of the screen or the left
Navigator > Filter / oil information, click item.
The type of data provided
 Fuel Filter
 Aircleaner
 Engine Oil Filter
 Hydraulic Oil Filter
 Pilot Filter
 Engine Oil
 Hydraulic Oil
 Coolant
 DPF
 Breather oil separator filter

Note: The type of data that can be provided by different models.

Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection.

Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
Initialization selection. If you click the reset button to initialize the selection using time
information for the selected item.
Replacement Cycle input. When you click on each filter change intervals in the column, type /
exchange period after the oil change intervals by letter button, You can change the saved filter /
oil change intervals within each machine.

Daily Operation Info View

You can find information in the daily operation of the machine. (Uptime, fuel consumption, Error
Code, Error Description, Error Count) Up to 180 days
Open the Daily Operation Info. Machine information at the top of the screen or the left
Navigator > Click on the Daily Operation Info View

The type of data provided


 Date
 Uptime
 Fuel Consumption
 Error Code
 Error Info
 Error Count

Note: The error codes of faults that occurred that day, the highest priority is displayed only one
thing.
Parameter View

You can view or modify the parameters of your device.

Open the Parameter View. Machine information at the top of the screen or the left Navigator >
Click the parameter entry.

The type of data provided.


 The main topics of the machine parameters (It varies from authority)

Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection. The details of the check group are displayed on the right side of the screen.

Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
Check the revocation items are not displayed on the screen.

Temporary application. Enter a value in the run value area, click the Apply icon ( ) This value is
stored in the RAM area of the machine is turned off before you can start operating the machine
to the specified value.

Apply. Enter a value in stored value area,, , Application icon ( )The value in the ROM area of the
machine before any changes can be saved to operate the machine to the specified value.

Parameter backup. You can back up parameter values shown on the current screen as an Excel
file. When you click the button, the user can save the file in the pop-up will be activated.

Restoring from a file. Restoring a backup to save modified parameters and then save the file or
to restore the parameters from a previously saved file.

Note: Only restore parameters Excel files can be created with the specified form when restored.

Create illustrative format:

ID Name Unit Min Max InitValue Run Value Stored value


1 - 0 10000 1800 0 0

Warning: Parameter modification feature is only available to users gateun the relevant authority.
Users who do not have the right to provide its functionality.

Backup/Restore

You can backup or restore all or part of the selected portion of the data stored on the device.
During restoration and prevent you from restoring the machine other than the machines that
were backed up by comparing the machine information.

Open Backup / Restore items. Screen Tools at the top of the Navigator > Click the Backup /
Restore item.
Select Save File. Click the Open File button and select the file you want to save the data.

Backup. When saving a file is selected will display the data that can be backed up. Select the
check box to select the desired data. After you click the Backup button, the data is backed up to
the specified file. Progress can be checked with the Progress Bar at the bottom.

Select Restore files. Click the Open File button and select the file you want to restore.

Restoration. After the restore, select the data file that can be restored are displayed. When you
select the desired data, select the check box and click the Restore button to restore the data from
the specified file. Progress can be checked with the Progress Bar at the bottom.

Warning: Backup / Restore function is available only to relevant gateun user rights. Users who do
not have the right to provide its functionality. If you want to randomly perform backup / restore
using the equipment may be limited.

ThumWheel Joystick Adjustable sensitivity

If the controller version provided ThumWheel Joystick sensitivity control function, The ThumWheel
Joystick sensitivity can be set by selecting each of the 11 steps and direction Joystick. In addition,
you can adjust the minimum operating speed in%.
Finally, you can adjust the reaction time of the Joytick in the range 0 ~ 10sec. That the above
functions can all revert to the default if you wish.
Note: That the above functions can all revert to the default if you wishThis feature will be
available, depending on the version of EPOS. (Ex: DX-3 Version 1.2 More than, DX-5 Version 1.1
More than)

Open ThumWheel Joystick sensitivity adjustment items. Screen Tools at the top of the
Navigator > Click ThumWheel sensitivity adjustment item.

Select the joystick. Joystick to the right, you can select the left.

Select the direction lever. You can select up and down directions of the joystick lever.

Lower Opt. Speed(%).You can select the minimum operating speed of the joystick lever in a
selected range between 0 and 100%. If the value is selected, you can see the values that are
changed via the Graph on the left side of the screen.

Selectivity. You can select the sensitivity of the joystick lever selected in the range from 0 to 10. If
the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.

Rise delay (sec). Ramp delay for rising within 0 ~ 10 (sec) range can be set in increments of 0.01.
If the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.

Fall delay (sec). Ramp delay the fall in the 0 ~ 10 (sec) range can be set in increments of 0.01. If
the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.

The default application. Revert to factory default settings.

Temporary application. By applying the selected value as a temporary, it can be tested.

Apply. By applying the selected value of the equipment, it can be applied until after the change.
EPOS Update(for controller)

You can install the Firmware of the device controller to the desired version. Firmware files, you
should use the files provided by the official route as a * .hex form

Open software updates. Screen Tools at the top of the Navigator > Click Software Updates.

Select the communications port. Select Communication Port to communicate on COM Port
combo box. If you are using an adapter, the COM Port UVIM will be displayed in green.

Reprogram. Clicking Reprogram button, a dialog box where you can select the desired Firmware
file is output. When you select the files you want the program to run. Overall progress is available
through the State Display and Progress bar.

State Display. And displays the progress, the software update algorithm, please see the following
Chart.

State Success Description Failed Description


[COMx] Port Open The COM Port for normal Can’t Open Port:
Connect!! communication has been Open. The state can not use the COM Port.
There is a problem with the re-
program files.:
Abnormal Firmware files have been
selected. Please try again in a normal
file.
Connecting with OK: Failed:
target… This controller has been properly Or the controller is not a BootMode,
connected. there may be a problem with
communication Cable or diagnostic
port.
Communication Communication kernel received Failed:
kernel is being and executing: This program has not been properly
sent... The program has been running sent to the controller. Please try again
successfully for the transfer is from the beginning.
complete, the controllers and
communication.
Connecting with OK: Failed:
target (second)... This controller has been properly There may be a problem with
connected. communication Cable or diagnostic
port.
FLASH Erasing.... OK: Failed:
FLASH of the controller has been FALSH Erase has not been made
properly emptied. properly.
CheckSum sent... OK: Failed:
Checksum of the program has Checksum of the program has not
been transferred successfully. been sent correctly.
Don't turn off your OK! You may now close this Failed:
device! window and reset the target. This program has not been
The program is completed successfully transmitted.
successfully. Close the program, to
restart the machine.

Important information: "Do not turn off your device!" State, do not block the communication
with the machine Also, do not reboot the machine It can cause a fatal error in the controller of
the machine.

Clear Display. Clear all the contents of the Display.

Close. Close the window.


Warning: Software Update feature is available only to relevant gateun user rights. Users who do
not have the right to provide its functionality. If you perform a software update, you can
optionally be limited to the machine in use.
Diagnosis of engine TIER3

Fault code

Until deleted by the user of the NDMS All messages remain in the ECU memory.
'Current' error message can not be deleted.
"Past" error message may be deleted.

The type of data provided


 Erase DTC: The user of the error status value of the ECU data can be deleted if the
previous state.
 Export…: The user can save the desired file.
 Fault Code: The user can check the error code.
 Description: It provides detailed information about each error.
 Activity: 'Present' is a failure means that now exist. 'History' means that the fault does not
currently exist.
 Help pop up: Click to view the online help for fault codes.

Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.

Freeze Frame. Click the freeze frame. You can view the environmental conditions when the error
occurred.

Fault code (Help Window). Clicking the fault code Help window opens. You can find more details
about the error, and, It makes it the preferred way for engine repair / check / check.
Click the radio button to open a bit Diagnostic Manual. You can find more details about the
error, and, It makes it the preferred way for engine repair / check / check.
Fault code (Freeze Frame). Click Description to open the description window. You can view the
environmental conditions when the error occurred.
Data Monitoring

Data monitoring can determine the sensor and the data values of the service engine Also, you

can check the status of sensors and switches in the electrical components.
Data Group. Select the Download menu, you can select the service data. (All data, Start data,
injector data, voltage data, fuel pressure data....)

Graph. It shows the value of each service selected data in a graph.

 Color: It indicates the line color of the graph.


 Service Data: Data indicates that the service name / parameter name displayed on the
graph.
 Variable : The current value is displayed on the screen is Y coordinates.
 maximum : It displays the maximum value of the service.
 Minimum : It displays the minimum value of the service.
 Time : X Coordinate
 Scroll Bar: Activated to display the next frame
 Stop Button : Temporarily stop the measurement on the graph
 Exit : Close the Graph window.

Save. Service Data name, parameter name, value and unit are stored in the current file.

Snapshot. Record the engine running for a long time and is available for viewing snapshots.

Run-up test

The run-up test is a test variation of the power performance of each cylinder.

Automatic. Start the engine to idle before pressing the start button. Choose Automatic from the
drop down menu. Press the Start button to start the test. Testing is carried out automatically six
times. 6 When the test is automatically stopped testing.

Manually. Select Manual from the drop-down menu. Select the cylinder to be tested. Press the
start button to perform the selected test cylinders only.
Status Messages. It shows the testing process.

Measuring Results.
 Result : This time the engine is accelerated measurements. If the shut-off of the cylinder
is much higher than -> It can be assumed that there is a defect in the cylinder or injection.
 Elapsed time : Idle RPM is to display the time at the minimum to the maximum is
reached.

Test shut-off

Shut-off test checks the status of each injector by blocking test.


Compression test

Start. Check the engine does not work, put the key in the "On" position. Press the Start button to
start the big engine rankings.

Stop. Clicking the test is stopped.

Status Messages. It shows the testing process. Always follow the instructions in the message
window.

Cranking message. Start immediately to start cranking. Stop stop cranking immediately.

Graph Description. Time compression and expansion of each cylinder. It shows the percentage
duration of the longest measurement time.
The program compresses the time axis of the expansion part and the other part is selected.
Assuming a compression ratio of cylinder compression time is shorter than the other cylinders.
The measurement time is short compression time interval, the expansion time is long part.
Remote Control

View the current value. It displays the current values of the parameters of the right-hand screen.

Start Remote Control. Replace the output signal of the ECU sensors through your computer.

Stop Remote Control. Stop the engine remote control.


 Select the data from the engine and remove the test.

Important information: Remote control operation method, please refer to the following
 'Input Variables' parameter is selected to send the input to the ECU.

 'When you click , then select 'Input Variable' is sent to the right of the screen.
 'Output Variables' output parameters are analyzed in ECU.

 Clicking the and then select 'Output Variable' is sent to the right of the screen.
 Click on 'View Current Value' You can see the current value of the selected parameter.
 Each puts the value of the apportioned value of the selected parameter in the 'Input' field.
 Press the remote control starts to see the results of the selected value.
 Press the remote control still shows the input value of the engine.

Register machine ID

The ECU can record the ID number and the engine of the equipment. After the ECU reprogram,
engine number and the machine serial number is not saved. You must save the engine number
and the machine serial number.
“Select in communication”.
 View all : press the 'view all' button to see all the EOL data.
 .CUID_D_DSID_CUC : Record the serial number and engine surfaces.
 .CUID_D_VIN_CUC : Make a note of the machine serial number.
 .CUID_D_VMS3_CUC : Record the machine model number.
 “Apply” : To apply the new values to the ECU.
 “Open selection” : Open the data items stored in the computer.
 “Save selection” : Save the selected data items.

Open. Open the value and specific service data previously stored.
Save. Save the data to a specific value.

Change the Data. Check the EOL to modify data values. “√” appears on the entry of ‘SEL’. Insert
a new value in the 'Value' column, click "Apply". The new value is stored in the ECU. The valid
input values, click the "Disconnect ECU" and wait for a few minutes. The new value is shown on
the ECU information.

Warning: Always, when you change the EOL data and ECU reprogram the engine must be
stopped. (The key is 'On' status)
Software Updates (for ECU)

Choose File. Select the ECU re-map file in a notebook or rework program, File is available from
Doosan.

Transferring files. Install the ECU map file, you can check the progress of the installation program.
Completing the installation (100%). "Communication end" is displayed, the installation is
complete.

Important information: After confirming the progress of the following conditions More
reprogramming.
 Ensure that the laptop battery has sufficient.
 If the proper transmission of the file fails, -> If the ECU is damaged, otherwise the
engine can no longer operate and must be replaced.
 After starting the engine again NDMS number, machine serial of the ECU using EOL, you
must re-enter.

ECU Info

The ECU can check the correct device to perform the test with the (hardware, software, machine

ID).
The type of data provided
 VIN: Serial number
 Engine Type: Surface / engine numbers
 The last used user: The ID number of the last recorded user data change
 Software Version: Software Version Displays
 Data set: Show map file versions
 Program data: EOL Displays the last modified data, If the data has not changed is
displayed as blank. Engine test data
 Engine test data show
 Model Number: Machine Model Number
Diagnosis of engine TIER4 Interim

Fault code

When you start the engine diagnostics, engine fails to display the error code and message.

Important information: Until deleted by the user of the NDMS All messages remain in the ECU
memory. 'Current' error message can not be deleted. "Past" error message may be deleted.

The type of data provided


 Erase DTC: The user of the error status value of the ECU data can be deleted if the
previous state.
 Export…: Users can save the desired file.
 Fault Code: The user can check the error code.
 Description: It provides detailed information about each error.
 Activity: 'Present' is a failure means that now exist. 'History' means that the fault does not
currently exist.
 Help pop up: Click to view the online help for fault codes.

Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.

Freeze Frame. Click the freeze frame. You can view the environmental conditions when the error
occurred.
Help. Click on the Diagnostic Trouble Code Manual is open. You can see the details of the error, It
will recommend a method for engine repair / check / check.

Data Monitoring
Data monitoring can determine the sensor and the data values of the service engine Also, you

can check the status of sensors and switches in the electrical components.
 Data Group
 Select the service data by selecting the Download menu
 You can choose the (All data, Start data, injector data, voltage data, fuel pressure
DPM After treatment dat).
 Show selection
 Select the check Sel to select a rectangle placed within the first service.
 It is shown in only selected parameters (service data) screen.
 Snapshot
 Snapshots can be recorded and displayed for the engine operating conditions.
 Graph
 It shows the value of each service data selected by the graph.
 Save
 Service Data name, parameter name, value and unit are stored in the current file.

Graph. It shows the value of each service selected data in a graph.


 Color: It indicates the line color of the graph.
 Data Services : Data indicates that the service name / parameter name displayed on the
graph.
 Variable : The current value is displayed on the screen is Y coordinates.
 Maximum : It displays the maximum value of the service.
 minimum : It displays the minimum value of the service.
 Time : X coordinate
 scroll bar: Activated to display the next frame
 stop button : Temporarily stop the measurement on the graph
 exit : Close the Graph window.
Run Up Test
The run-up test is a test variation of the power performance of each cylinder.

Ex) Pictures of Blue saekseon displays all cylinders work.


According to the order from # 1 and # 6 cylinder is stopped, ECU is A, B, C, D, E, F, the graph is
displayed and estimated point. When compared to other lines, respectively, of each cylinder
combustion you can see that yellow. If the slope of the absence of a cylinder similar to the
cylinder inclination is bad state.

Shut-Off Test
Shut-off test is to determine the variation in the state of each injector.
 Testing Procedure:
 Down menu by selecting the select cylinder
 Click the Start button,
 Compared to the other cylinders
Input/Output Test
This is to control the actuators of the engine part and, You can check the condition of the
actuator.

Status Box. The contents of the status box, check the status of the engine is operating.
 Engine : Engine on/Off
 IG.Key : ignition key on/off
 Control : Activation
 Value : Input value
 MIN/MAX : Range

Results box. The contents of the box are the output results after the test engine.
Boost pressure actuator Test Procedure.
A. This test can tell the VGT normal operation.
B. Select the boost pressure actuator test.
C. Press the Start button.
D. Enter a value in the 'value' box.
E. Check the VGT shaft with the naked eye.
F. Click Return to ECU.

Epm_nEng Test Procedure required.


A. This test verifies the normal operation of the engine RPM.
B. Enter a value in the 'value' box.
C. Press the Start button
D. Make sure the display screen, the result of an incubator.
E. Click Return to ECU.

Glow lamps Signal Test Procedure.


A. This test verifies the normal operation of the engine lamp.
B. Enter a value in the 'value' box.
C. Press the Start button.
D. Check the engine lamp on the display panel.
E. Click Return to ECU.

Test Procedure throttle valve actuator.


A. This test verifies the normal operation of the throttle valve.
B. Enter a value in the 'value' box.
C. Press the Start button
D. Check the normal operation to the naked eye
E. Click Return to ECU.

Test Procedure cylinder shut-off signal


A. This test is to verify the proper operation of the injector.
B. Enter a value in the 'value' box.
C. Press the Start button
D. Check the engine lamp on the display panel.
E. Click Return to ECU.
EOL
You can change the value of each component.

Important information: If (PRV values, Ash, DPF value) must be changed, click the button below.
If you do not click on the Change button and components, The ECU continues to calculate the
extent of the part, and, Part 3 is a fault code will be generated.

Software Updates (for ECU)


Choose File. Select the ECU re-map file in a notebook or rework program, File is available from
Doosan.

Transferring files. Install the ECU map file, you can check the progress of the installation program.

Completing the installation (100%). "Communication end" is displayed, the installation is


complete.

Important note: After confirming the progress of the following conditions More reprogramming.
 Ensure that the laptop battery is sufficient.
 If the proper transmission of the file fails And the ECU is damaged or otherwise
need to be replaced if the engine can no longer operate.
 After starting the NDMS again using EOL engine number, equipment serial of the ECU
must be re-entered.
Reprogramming Procedure.
 Map file selected in the notebook.
 Press the Start version, you can check the progress.

ECU Info
The type of data provided
 ECU Hardware numbers: ECU Hardware Version Displays
 VIN Data ID: Displays the vehicle serial number
 ECU Software Version: ECU Software Version Displays
 Engine Type: Surface / engine numbers
 Program Data: EOL Display data modification date, Be blank if no data is changed
 Map Version: Show Map Version
 Model No. Machine model number
Trouble Shooting

Important information: When contact your representative if you pass as the error codes below
can help you troubleshoot.

State CODE Description


Communication Port The Port is in use or
abnormal behavior.
• Check the status of the Serial Port.
Can't Open Port FAD1001 • Make sure the Port is being used by another
program.
• Ensure that the operating normally Driver of the
Port.
Check Engine State{0} The conditions for the functioning does not fit.
FAD1002
Engine OFF, IG.Key ON • Make sure the engine Off, Ignition Key On State
This does not meet the conditions for the
Check Engine State{0}
FAD1003 functioning.
Engine On, IG.Key ON
• Make sure the engine On, Ignition Key Off state
This version does not conform to the engine
Check Engine ECU
FAD1004 perform their functions.
Version :
• Check the version of the engine.
There is no response from the ECU.
• Make sure the power is supplied to the ECU.
(Equipment driven state)
• Check the communication status. (Cable,
Connector tightening status.)
• Make sure you have the same notification also
Not Response from occurs in the Gauge panel
FAD1005
ECU. - If the same occurs in the gauge panel alerts,
check the communication connection between the
ECU.
• Make sure that the ECU information of the ECU
and the equipment selected in the program the
same model.
• Verify that the problem also perform other
functions.
• If you have problems in performing other
functions, please contact the administrator for the
notification.
There is no response from the ECU.
• Make sure the power is supplied to the
ECU.( Driven state machine)
• Check the communication status.
(Cable, Connector tightening status)
• Make sure you have the same notification also
occurs in the instrument cluster.
- Make sure you have the same notification also
Check Connection State
FAD1006 occurs in the gauge panel.
to ECU
• Make sure that you selected in the ECU
information of the ECU program with the same
model machine.
• Verify that the problem also perform other
functions.
• If you have problems in performing other
functions, please contact the administrator for the
notification.
There is no response from the ECU.
• Make sure the power is supplied to the
ECU.( Driven state machine)
• Check the communication status.
(Cable, Connector tightening status)
• Make sure you have the same notification also
occurs in the instrument cluster.
Connect to ECU Fail. FAD1007
- Make sure you have the same notification also
occurs in the gauge panel.
• Make sure that you selected in the ECU
information of the ECU program with the same
model machine.
• Verify that the problem also perform other
functions.
• If you have problems in performing other
functions, please contact the administrator for the
notification.• 다른 기능 수행에도 문제가 있다면,
해당 알림에 대해 담당자에게 문의 바랍니다.
Check Engine
State{0}Engine OFF, The conditions for the functioning does not fit
IG.Key ON.{0}(Engine • Make sure the engine Off, Ignition Key ON
will be stopped FAD1008 state.
soon.){0}After using this • After performing the function, then re-start the
function. you have to program and the machine.
restart this program
ECU and was not shut down properly connected.
• Restart your machine.
Exit Session Fail! FAD1009
• Please contact your representative if a problem
occurs consistently after.
The ECU is communicating deny state.
• Make sure the other features the same alert
occurs.
• After restarting the machine even when the
Negative response! FAD1010
retry hayeoteul make sure that the same
notification will occur.
• Please contact your representative if a problem
occurs consistently after.
ECU information selected is invalid.
Ecu Type select FAD1011 • Check the ECU information ECU information
associated with the selected.
The driving force driving force for performing ON
not taken.
State of ForceOperation
FAD1012 • Please turn ON the first driving force.
is not ON
• Items will be ON the driving force to change
the background color.
The Value of Type has been entered wrong.
Check the type. FAD1013
• Enter the Value of a given Type.
UVIM Initialization Fail. UVIM failed initialization.
FAD1014
Check the Engine • Make sure you select the correct engine Type.
type(T3, T4I) and state (Tier3, Tier4)
of ECU. • The correct power to the ECU, make sure that
the drive is applied.
• Check the version of UVIM driver.
It does not recognize the correct type information
Can not read Vehicle from the connected machine.
Information. Check • Make sure you select the correct machine Type.
FAD1015
COM State and try • Check the status of communication Cable.
again please! • Start> Device Manager> Check the status of the
communication Port in Ports (COM & LPT).
Normal data is not received.
• Check the communication status of the
There is a problem with
FAD1016 machine.
the reprogram files.
• Please contact your representative in case of
persistent problems after restarting the machine.
This is not a valid update file.
There is a problem with • Make sure that the update file connected to the
FAD1017
the reprogram files. machine.
• Use the update files get re-downloaded.
Try the update again, but the update failed
because the normal response is not received from
the ECU.
• Check the communication status of the
Failed reprogramming. FAD1018 machine.
• Make sure the machine is normally driven state.
(Engine Off, Ignition Key On)
• Please contact your representative in case of
persistent problems after restarting the machine.
There is no response from the machine.
• Make sure the machine is normally driven.
• Check the communication status. (Cable,
No reponse in time. FAD1019 Connector tightening status)
• Verify that the problem also perform other
functions.
• If you have problems in performing other
functions, please contact the administrator for the
notification.
There is no response from the machine.
• Make sure the machine is normally driven.
• Check the communication status. (Cable,
Connector tightening status)
No reponse in time.
FAD1020 • Verify that the problem also perform other
Check COM State.
functions.
• If you have problems in performing other
functions, please contact the administrator for the
notification.
The input format is It is not the correct file is selected,
FAD1021
invalid. • * .accdb file, select the correct form.
Failed to initialize the connection ECU.
• Make sure you select the correct engine Type.
(Tier3, Tier4).
• The correct power to the ECU, make sure that
Failed to initialize the drive is applied.
FAD1022
communication • Check the version of UVIM driver.
• Check the version information of the ECU.
• If the problem continues to occur even perform
other functions, please contact your
representative.
Type definitions of some of the data is incorrect.
Can not find the type. FAD1023 • If the problem continues to occur, contact your
stately character and obtain a new DataBase.
Type the correct ECU is not selected.
• Make sure you select the correct engine Type.
(Tier3, Tier4)
• The correct power to the ECU, make sure that
This is not normally the
FAD1024 the drive is applied.
type selected.
• Check the version of UVIM driver.
• Check the version information of the ECU.
• If the problem continues to occur even perform
other functions, please contact your
representative.
A problem has occurred in the communication.
• Check the communication connections.
• Start> Device Manager> Check the status of the
communication Port in Ports (COM & LPT).
Check COM State. FAD1025
• Make sure the Port in use by another program.
• Retry after restarting the machine.
• Please contact occurs, personnel issues
consistently.
A problem has occurred in the communication.
• Check the communication connections.
Failed to initialize • Make sure the Port in use by another program.
FAD1026
communication • Retry after restarting the machine.
• Please contact occurs, personnel issues
consistently.
Choose the file is currently in use by another
The current file is in
program.
use . Please restart to FAD1027
• Retry after the end of the other programs you
close the file in use.
are using.
Communication Port, has not been properly
Occupied a problem
recognized.
while reading the serial FAD1028
• Start> Device Manager> Check the status of the
port in WMI:
communication Port in Ports (COM & LPT).
The input of the Format that can be transferred is
Input Error: FAD1029 not within the CAN Bus.
• Modify the input normally retry.
Type definitions of some of the data is incorrect.
System selection is
FAD1030 • If the problem continues to occur, contact your
incorrect.
stately character and obtain a new DataBase.
An error occurred during the update program.
Occured Error: {0} Retry • Retry after restarting your machine.
FAD1031
Update Program • If the problem persists, please contact your
representative to convey its message.
Program data # on the problem occurred.
ProgrammingData FAD1032
• Make sure that the correct programming data.
• Do change the programming data.
A problem has occurred in the communication.
• Check the communication connections.
• Start> Device Manager> Check the status of the
No reponse in time.
communication Port in Ports (COM & LPT).
Please restart program FAD1033
• Make sure the Port in use by another program.
and machine.
• Retry after restarting the machine.
• Please contact occurs, personnel issues
consistently.
Delete past failure history has failed.
• Retry it may be a communication error.
Failed Delete Fault Code
FAD1034 • Retry later, even if the city continues to cause
History
problems, Please contact us with Version of the
machine to personnel.
It failed to authenticate users.
• When connected to Doosan AD account, you
LogIn Fail: Unknown ID will be connected to Doosan in-house networks.
FAD1035
or wrong Password. • If the ID and password from the grant date
service information, please contact us by passing
a version of the program to the representative.
Not Registered
The registry key is invalid.
Machine. To use this
FAD1036 • We reaffirm the key to the registry key
program you must
personnel.
activate.

You might also like