Professional Documents
Culture Documents
User’s Guide
For Integrated DMS-5 Software
Contents
DMS Program User’s Guide ................................................................................................................................................. 1
Tool ........................................................................................................................................................................................... 6
Machine Function............................................................................................................................................................. 6
Communication Connection....................................................................................................................................... 8
Report .................................................................................................................................................................................. 12
Export .................................................................................................................................................................................. 13
Start................................................................................................................................................................................................ 14
Login ..................................................................................................................................................................................... 14
Tool ................................................................................................................................................................................................. 17
Open the graphical log file (Play) ....................................................................................................................... 17
Monitoring ........................................................................................................................................................................ 21
Graph.................................................................................................................................................................................... 22
Backup/Restore .............................................................................................................................................................. 34
ECU Info.............................................................................................................................................................................. 51
EOL ........................................................................................................................................................................................ 61
ECU Info.............................................................................................................................................................................. 62
The Doosan Excavators / Wheel Loaders Monitoring Program (aka DMS) e-EPOS controller is
mounted on excavator Or VCU controller mounted on the wheel loader, and the engine controller
provides the following function using the communication between the (ECU) and an IBM, -In
function is a function to function as an engine for the device to distinguish and, Each feature is
configured to automatically screen depending on the connected model.
The main functions can be selected with the Top navigator and Left navigator. The selected
function is displayed on the main display screen, You can check the current status in the state bar.
General function
Function Description
Report You can report key information, such as the main sensor
data and uptime information of the machine.
Pleaes refer to the report function.
Export You can save the data identified in each function.
Pleaes refer to the Export function.
Select Machine You can choose to connect to the machine or engine
model. Communication preferences are set automatically.
Pleaes refer to the Select Machine function.
Property You can set the language of the application or output
units. Pleaes refer to the Property function.
Start You can begin to communicate with the machine. Start
the communication about the features that are currently
running on the main screen.
Stop You can stop the communication with the machine. Stop
the communication of the features that are currently
running on the main screen.
Refresh Refresh the current running function for the main screen.
Tool
Function Description
Load Graph Log You can play the graph data storage.
File Pleaes refer to the Load Graph Log File function.
Manual View You can view the program help.
CAN Bus You can monitor the communication data of the CAN
Monitoring bus is the machine.
Pleaes refer to the CAN Bus Monitoring function.
TMS Terminal You can check the status of the TMS Terminal.
Status Pleaes refer to the TMS Terminal Status function.
Sanp Shot You can view the saved engine monitoring data.
Pleaes refer to the Sanp Shop function.
Machine Function
Function Description
Machine Info You can see the basic information, such as machine
model, serial number and version of the program of the
machine.
Monitoring It shows real-time information of the key sensors of the
machine to List or Gauge Panel form.
Graph You can see the real-time information on the important
sensor of the machine in graphic form.
Force Operation The output of the machine controller can be artificially
simulated by driving force, build a variety.
Parameter You can view or modify the machine control parameters.
Pleaes refer to the Parameter function.
Fuel Consum You can check or reset the fuel used information from
the machine.
Operation Hours You can check or reset the period-specific information in
the machine uptime.
Daily Oper. Info You can check or reset the daily operating information
of the machine.
Filter/Oil Info Check the filter / oil change intervals and the operating
time of the machine or modified, can be reset.
Fault Info You can check or reset the current faults and past faults
history of the machine.
Backup/Restore You can back up or restore the information stored in the
machine controller.
Software Update You can change the firmware of the machine controller
to the desired version.
Engine Function
Function Descriptiom
ECU Information The basic information such as the model name, serial
number and version of the program of the engine.
Monitoring It shows the important sensor and services data of the
engine to List or graph form. You can store data over a
snap shot function.
Snap Shot You can play the data through a snap shot function.
Fault Code You can check or reset the current faults and past faults
of the engine.
RunUp Test It is possible to test the performance of individual
cylinders of the engine.
ShutOff Test To switch off the injection of the selected cylinder
engine can be a shutoff test.
Input/Output It is possible to control the engine actuator test the
Control actuator status.
EOL You can change the PRV Valve and Ash and DPF.
Program Setup
You have to run SETUP.EXE program to automatically install the DMS. Please contact the program
manager if the monitor, the screen of the graph outputs, such as would normally appear when
you run the program after installation is complete.
To run the DMS program at a built-in over Windows XP OS IBM PC-compatible computer is
required.
Note: You must use a separate Adapter is certified Adapter provided by the company.
Communication Connection
In order to perform communication with an external PC and the machine requires a separate
communications cables. Communication cables must be connected to a COM port or a separate
Kit Adpater the inspection connector mounted on the machine with your PC.
Note) When removal of the communication cable is performed in the state, please disconnect the
power source of the excavator.
Communication Cable
Equipment that can be connected to the diagnostic port 3Pin, 14Pin have a cable, General RS232
cable, you can connect a USB type and the PC. Also, to connect to the engine controller can be
configured as a separate UVIM Adapter.
3 Pin Cable. 3 Pin cable diagnostics port, you can connect using the Equipment consists of 3 Pin.
14 Pin Cable. 14 Pin cable diagnostics port, you can connect using the Equipment consists of 14
Pin.
UVIM Apdater. UVIM ADpater connections at the same time by using the equipment and the
engine controller, you can check the machine or engine information. If you use the adapter, you
can UVIM than the PC connection via USB.
RS232 Cable. You can use the RS232 port and RS232 Cable to connect your PC. Depending on
the status of the PC RS232 to USB cable is required.
WARNING: If you use an unauthorized cable may not be normal communication is not
performed.
Communication Preferences
To communicate with the machine and engine Select a model of machine or engine during the
start of the program, Select the desired communication Port will be automatically communication
preferences. If you click the Apply button to start the communication with the machine.
Note: Solar, DL Model is Baudrate 9600, DX Model is 57600, and others have excluded the engine
and set to 115200 by default.
Support Models Select Model
Note: If the model is not identified in the list included by default in the model of the machine -3
U, H Model select, and if -5 is included, select V, K, C Model. Please contact us for additional
models are not identified as a Program Coordinator.
Communication state check. The right of the State Bar LED is lit, the LED during transmission /
reception, you can check the communication status.
Program Preferences
You can set the default language, units of the program. If the language change will apply when
Open the program Preferences items. Click Home> Settings item in the Navigator at the top of the
screen. ( )
The type of configuration data
Setting Language (Korean, English, Chinese, Russian, Spanish, Portuguese, French, Dutch)
Skin Settings program : Dark, Mac, Windows 7, Caramel, Whiteprint, Metropolis Dark,
Metropolis
unit setting
Pressure, Temperature, Volume, Fuel consumption, Speed, Flow rate
Setting Language. Home> Go to Settings, and then restarted when you apply the setting item
and then select the language of the program.
Skin Setting program. Home> Go to Settings, and then choose the desired skin can be applied
to the program Program Skin entries.
Unit setting. Home> Go to Settings, and then can be applied to select the desired unit of a unit
setting item.
Report
You can gather the main data of the machine and save the form as a report. You can share via E-
mail or any other sharing programs, depending on your PC environment.
Open Report Item. At the top of the screen Navigator Home> Click the report item. ( )
Export
You can save a file type that is currently done by collecting data. You can share via E-mail or any
other sharing programs, depending on your PC environment.
Open export items. Home > Click the Export item at the top of the screen. ( )
Start
Login
Login of the machine is divided into AD authentication system and installing H / W based
Registry Key registration method of the Doosan Group. Registry Key registration is available the
receiving grants Key generated based on the information in the program is installed H / W.
function Start, Stop, Refresh, Exit
By default, the start of communication via the start button, when performing the functions of the
program, and, during the stop, click Cancel. Stop automatically runs when you switch on each
screen.
Start Communication. In the Navigator, click the Start button at the top of the screen. When you
click the Start button, stop button is activated, the Start button is disabled.
Stop Communication. Click the Stop button in the Navigator at the top of the screen. If you click
the Stop button the start button is activated, the Stop button is disabled.
Refresh. Click the Refresh button in the Navigator at the top of the screen. Refresh is used for
The program will display the basic information of the normal equipment and communication
equipment are made, the Main Screen. The machine information can be checked through the
mechanical information function.
Open the machine infomation. Machine Information > In the Navigator at the top of the screen,
click the Machine Information topic. ( )
Machine Condition: The total running time of the machine, you can check the current
failure count.
Tool
You can play the stored graphical log file. And analyze the data for the entire trend analysis, and
the specific conditions of the data stored by the graph view..
Open graph of log file entries. Screen Tools at the top of the Navigator > Click on the graph log
file open items ().
Check the values in the graph. (Action: Mouse Over) If the Mouse Over a graph screen graph
of the data values in Mouse Cursor time are displayed on the screen.
When performing a communication through a machine controller and UVIM Adapter, you can
monitor the signal of the CAN Bus equipment. If it is connected via the CAN device controller and
UVIM Adpater, you can use the feature.
CAN Bus Monitoring Open Items. Screen Tools at the top of the Navigator > Click on the CAN
Bus Monitoring item ().
Transmit Message. You can send your ID and Data via the CAN Bus. Enter the ID and Data and
click the Send button to send the data to the CAN Bus.
Data Logging. If you check the log file, you can save data to a file of the CAN Bus.
Send Data. Make the desired CAN Message can be sent to the control unit.
Opening the TMS Terminal Status Item. Screen Tools at the top of the Navigator > Click TMS
Terminal Status item
Security release. You can turn off the machine Lock feature of the TMS Terminal.
Snap Shot
Open topic Snap Shot. Screen Tools at the top of the Navigator > Click the Snap Shot item.
Open. You can call up the saved Engine Monitoring Data. (*.snap)
Graph. You can view the imported Data in Graph.
X2 Start. You can play back the stored Data 2-speed roads.
Monitoring
To read various data associated with the machine in real time. The data show a List form, by
default, you can choose an item to select the data you want to see. After selecting the desired
data, you can perform the communication with the device via the Start / Stop button in the Top
Navigator.
See the data types can be found in List, Graph, Gauge Control.
The type of data provided
Sensor data : Data of the frequency and analog sensors
Engine speed (rpm), Battery voltage (V), FRONT PUMP Pressure / REAR PUMP etc.
Digital input / output state: Data of ON / OFF type sensors, such as various switches, the
control state
Start Switch, Alternator, etc.
Open machinery monitoring. Machine information at the top of the screen or the left Navigator
> Click the Monitoring item. ( )
Open Graph View. Machine information at the top of the screen or the left Navigator > Click the
Graph item. Or click on the graph view in the Main Screen.
Show controls. Click the View Control in the Main Screen.
Select Monitoring Group. So you can select the items you want to monitor to switch to List View
screen. When you select the desired data is updated value of the selected data. This button is
activated only view control.
Communication period setting. It sets the period of the data received from the machine.
Transmission cycle can be set up to 10msec ~ 2550msec. However, this feature is not supported
for models this item will not be visible.
Graph
Can identify a variety of data relating to the machine in real time, The data show the Graph type
by default, select the data selection (monitor screen), you can select the data you want to see.
After selecting the desired data, you can perform the communication with the device via the Start
/ Stop button in the Top Navigator.
The type of data provided
Sensor Data : Data of the frequency and analog sensors
Engine Speed(rpm), Battery voltage (V), FRONT PUMP Pressure / REAR PUMP
pressure, etc.
Digital input / output state: Data of ON / OFF type sensors, such as various switches, the
control state
Start switches, alternators, etc.
Note: If you have a long time to collect data stored in a file via the Export function, open the
graphical log file (play) it is effective analysis functions.
Open View Machines graph. Machine information at the top of the screen or the left Navigator
> Click the Graph item or mechanical information. ( ) > Click on the button in the graph view
monitoring item.
Select Monitoring Group. If you click the Select button to switch to monitoring data List
selection Page. Select the desired data and press the Graph View icon to switch to graph view
screen.
View individual graph. You can view the data that is being monitored as a separate graph. If a
check function is activated and deactivated when the check revocation.
Logging File Save. Save a file for the data being monitored. If the left Navigator > Click the
Export item, function is activated. When the user activates the pop-up function for saving a file is
output. You can save the file to the desired name in the desired position. The files are saved as
* .csv form. Data is stored at the top of the Navigator tool > Open the log file can be played with
graph functions. You can also edit the desired shape through the editable program for saved files.
(Ex: Micosoft Excel)
Communication period setting. It sets the period of the data received from the machine.
Transmission cycle can be set up to 10msec ~ 2550msec. However, this feature is not supported
for models this item will not be visible.
View selected Y-axis data. The check items for viewing the Y-axis value of the data. When you
select the Check Box of the data that you want to see Y Y-axis values of the graph axes it is
added. In addition, so that the thickness of the thick graph makes it easier to distinguish between
the selected data.
Key+Mouse Functions. When you click this item, you can see a description of the functions that
can be performed by combining the operations of the Key and Mouse, such as zoom in / out /
move the graph pop-up Screen.
Division Action
shift + LeftMouse Drag Zoom into Selection.
shift + Alt + LeftMouse Drag Zoom into proportional selection.
shift + LeftClick Zoom in around point.
shift + UpArrow Zoom in around middle of plot area.
shift + DownArrow Zoom out around middle of plot area.
shift + MouseWheel Zoom in/Zoom out.
shift + RightClick Undo.
shift + Baclspace Reset.
Ctrl + LeftMouseDrag Pan.
Ctrl + LeftArrow Pan left.
Ctrl + RightArrow Pan right.
Ctrl + UPArrow Pan Up.
Ctrl + DownArrow Pan down.
Ctrl + RightClick Undo.
Ctrl + Backspace Reset.
Check the values in the graph. (Action: Mouse Over) If the Mouse Over a graph screen graph
of the data values in Mouse Cursor time are displayed on the screen.
You can read about current / past information relating to machine malfunction. (Fault Code, failure
information and actions to take (Manual) and time of occurrence of past failures)
Open Fault Information. Machine information at the top of the screen or the left Navigator >
Click fault information items ().
Delete past failure history. Clicking the past fault history Delete button you can delete or
initialize the past failure information is stored.
Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.
Force Operation
The output of the machine control is a function to forcibly drive. It can be artificially achieved by
the implementation in the actual system, difficult by this function. Activates the driving force to
the driving force to the selected items, It is divided into two and applying the actual value, If the
driving force function is enabled (ON) of afterwards, it can not be applied to the driving force
value.
Note: The type of data provided may be different for each model.
Open ForceOperation entry. Machine information at the top of the screen or the left Navigator >
Click the ForceOperation entry ().
Select the ForceOperation entry. Please check all the items, select the check box at the bottom
of each item or selection.
Off the ForceOperation entry. Turn off the Select or deselect the check box of each item at the
bottom.
ON the ForceOperation choices. Clicking on the selection ForceOperation ON button to turn ON
the ForceOperation for the selected item.
Off the ForceOperation choices. Clicking off the selection ForceOperation off button to turn off
the ForceOperation for the selected item.
ForceOperation value input. ForceOperation to specify the number in the value field of the
application screen. Or to adjust the value of the control bar of the applicable value to the desired
value.
ForceOperation apply. If you click the Apply icon of each item will ForceOperation the machine
to the value entered in the applicable value.
Combining a pop-up screen to the Main screen. A pop-up screen with the mouse to drag an
icon from which you can select the desired location on the main screen will be activated ( ).The
pop-up screen When you release the mouse in the desired position will be joined to the Main
screen.
Warning: ForceOperation has got the power to drive a mechanical force, only gateun users can
use the associated privileges. Users who do not have the right to provide its functionality.
Warning: When you exit the test ForceOperation home within the program, information
machines, tools > Click the Stop button or click the selection Forceoperation OFF button must be
stopped Forceoperation Because so should the machine is working properly. Or cycle the start-up
of the machine gun and restarts the action.
Fuel Consumption View
You can check the fuel consumption using the machine in each mode, which provides machinery.
You can reset the fuel consumption is stored in the machine.
Open the Fuel Consumption view. Machine information at the top of the screen or the left
Navigator > Click on the fuel Consumption items.
Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection.
Off initialization entry. Turn off the Select or deselect the check box of each item at the bottom.
Initialization selection. When you click the Reset button to reset the usage information for the
selected item.
Warning: Fuel consumption initialization function is available only to relevant authorized users
gateun. Users who do not have the right to provide its functionality.
You can check the uptime information for the items specified in the mode-specific or hydraulic oil
temperature, coolant temperature, etc. Group of machines.temperature, coolant temperature, etc.
Group of machines. Uptime is the time in each mode, except for chonggadong can optionally be
reset.
Open the Operation hours view. Machine information at the top of the screen or the left
Navigator > Operation hours view, click the item.
Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
The unchecked item can not verify the information in the List on the right.
Initialization selection. When you click the Reset button to reset the usage information for the
selected item.
warning: Uptime initialization function is available only to relevant gateun user rights. Users who
do not have the right to provide its functionality.
View a group-specific data Bar Char. (Action: Mouse Click) If you click the Group name is the
data values of the selected group it will be displayed on the screen at the bottom of a Bar Chart.
Filter/Oil Info
You can check the machine's filter / oil change intervals and the use of time. In case replace the
filter / oil set a new replacement cycle, or you can reset the usage time.
Open Filter / oil information items. Machine information at the top of the screen or the left
Navigator > Filter / oil information, click item.
The type of data provided
Fuel Filter
Aircleaner
Engine Oil Filter
Hydraulic Oil Filter
Pilot Filter
Engine Oil
Hydraulic Oil
Coolant
DPF
Breather oil separator filter
Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection.
Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
Initialization selection. If you click the reset button to initialize the selection using time
information for the selected item.
Replacement Cycle input. When you click on each filter change intervals in the column, type /
exchange period after the oil change intervals by letter button, You can change the saved filter /
oil change intervals within each machine.
You can find information in the daily operation of the machine. (Uptime, fuel consumption, Error
Code, Error Description, Error Count) Up to 180 days
Open the Daily Operation Info. Machine information at the top of the screen or the left
Navigator > Click on the Daily Operation Info View
Note: The error codes of faults that occurred that day, the highest priority is displayed only one
thing.
Parameter View
Open the Parameter View. Machine information at the top of the screen or the left Navigator >
Click the parameter entry.
Select initialization entry. Please check all the items, select the check box at the bottom of each
item or selection. The details of the check group are displayed on the right side of the screen.
Off initialization entry. Turn off the Select or deselect the check box of each item on the bottom.
Check the revocation items are not displayed on the screen.
Temporary application. Enter a value in the run value area, click the Apply icon ( ) This value is
stored in the RAM area of the machine is turned off before you can start operating the machine
to the specified value.
Apply. Enter a value in stored value area,, , Application icon ( )The value in the ROM area of the
machine before any changes can be saved to operate the machine to the specified value.
Parameter backup. You can back up parameter values shown on the current screen as an Excel
file. When you click the button, the user can save the file in the pop-up will be activated.
Restoring from a file. Restoring a backup to save modified parameters and then save the file or
to restore the parameters from a previously saved file.
Note: Only restore parameters Excel files can be created with the specified form when restored.
Warning: Parameter modification feature is only available to users gateun the relevant authority.
Users who do not have the right to provide its functionality.
Backup/Restore
You can backup or restore all or part of the selected portion of the data stored on the device.
During restoration and prevent you from restoring the machine other than the machines that
were backed up by comparing the machine information.
Open Backup / Restore items. Screen Tools at the top of the Navigator > Click the Backup /
Restore item.
Select Save File. Click the Open File button and select the file you want to save the data.
Backup. When saving a file is selected will display the data that can be backed up. Select the
check box to select the desired data. After you click the Backup button, the data is backed up to
the specified file. Progress can be checked with the Progress Bar at the bottom.
Select Restore files. Click the Open File button and select the file you want to restore.
Restoration. After the restore, select the data file that can be restored are displayed. When you
select the desired data, select the check box and click the Restore button to restore the data from
the specified file. Progress can be checked with the Progress Bar at the bottom.
Warning: Backup / Restore function is available only to relevant gateun user rights. Users who do
not have the right to provide its functionality. If you want to randomly perform backup / restore
using the equipment may be limited.
If the controller version provided ThumWheel Joystick sensitivity control function, The ThumWheel
Joystick sensitivity can be set by selecting each of the 11 steps and direction Joystick. In addition,
you can adjust the minimum operating speed in%.
Finally, you can adjust the reaction time of the Joytick in the range 0 ~ 10sec. That the above
functions can all revert to the default if you wish.
Note: That the above functions can all revert to the default if you wishThis feature will be
available, depending on the version of EPOS. (Ex: DX-3 Version 1.2 More than, DX-5 Version 1.1
More than)
Open ThumWheel Joystick sensitivity adjustment items. Screen Tools at the top of the
Navigator > Click ThumWheel sensitivity adjustment item.
Select the joystick. Joystick to the right, you can select the left.
Select the direction lever. You can select up and down directions of the joystick lever.
Lower Opt. Speed(%).You can select the minimum operating speed of the joystick lever in a
selected range between 0 and 100%. If the value is selected, you can see the values that are
changed via the Graph on the left side of the screen.
Selectivity. You can select the sensitivity of the joystick lever selected in the range from 0 to 10. If
the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.
Rise delay (sec). Ramp delay for rising within 0 ~ 10 (sec) range can be set in increments of 0.01.
If the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.
Fall delay (sec). Ramp delay the fall in the 0 ~ 10 (sec) range can be set in increments of 0.01. If
the value is selected, you can see the values that are changed via the Graph on the left side of
the screen.
Apply. By applying the selected value of the equipment, it can be applied until after the change.
EPOS Update(for controller)
You can install the Firmware of the device controller to the desired version. Firmware files, you
should use the files provided by the official route as a * .hex form
Open software updates. Screen Tools at the top of the Navigator > Click Software Updates.
Select the communications port. Select Communication Port to communicate on COM Port
combo box. If you are using an adapter, the COM Port UVIM will be displayed in green.
Reprogram. Clicking Reprogram button, a dialog box where you can select the desired Firmware
file is output. When you select the files you want the program to run. Overall progress is available
through the State Display and Progress bar.
State Display. And displays the progress, the software update algorithm, please see the following
Chart.
Important information: "Do not turn off your device!" State, do not block the communication
with the machine Also, do not reboot the machine It can cause a fatal error in the controller of
the machine.
Fault code
Until deleted by the user of the NDMS All messages remain in the ECU memory.
'Current' error message can not be deleted.
"Past" error message may be deleted.
Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.
Freeze Frame. Click the freeze frame. You can view the environmental conditions when the error
occurred.
Fault code (Help Window). Clicking the fault code Help window opens. You can find more details
about the error, and, It makes it the preferred way for engine repair / check / check.
Click the radio button to open a bit Diagnostic Manual. You can find more details about the
error, and, It makes it the preferred way for engine repair / check / check.
Fault code (Freeze Frame). Click Description to open the description window. You can view the
environmental conditions when the error occurred.
Data Monitoring
Data monitoring can determine the sensor and the data values of the service engine Also, you
can check the status of sensors and switches in the electrical components.
Data Group. Select the Download menu, you can select the service data. (All data, Start data,
injector data, voltage data, fuel pressure data....)
Save. Service Data name, parameter name, value and unit are stored in the current file.
Snapshot. Record the engine running for a long time and is available for viewing snapshots.
Run-up test
The run-up test is a test variation of the power performance of each cylinder.
Automatic. Start the engine to idle before pressing the start button. Choose Automatic from the
drop down menu. Press the Start button to start the test. Testing is carried out automatically six
times. 6 When the test is automatically stopped testing.
Manually. Select Manual from the drop-down menu. Select the cylinder to be tested. Press the
start button to perform the selected test cylinders only.
Status Messages. It shows the testing process.
Measuring Results.
Result : This time the engine is accelerated measurements. If the shut-off of the cylinder
is much higher than -> It can be assumed that there is a defect in the cylinder or injection.
Elapsed time : Idle RPM is to display the time at the minimum to the maximum is
reached.
Test shut-off
Start. Check the engine does not work, put the key in the "On" position. Press the Start button to
start the big engine rankings.
Status Messages. It shows the testing process. Always follow the instructions in the message
window.
Cranking message. Start immediately to start cranking. Stop stop cranking immediately.
Graph Description. Time compression and expansion of each cylinder. It shows the percentage
duration of the longest measurement time.
The program compresses the time axis of the expansion part and the other part is selected.
Assuming a compression ratio of cylinder compression time is shorter than the other cylinders.
The measurement time is short compression time interval, the expansion time is long part.
Remote Control
View the current value. It displays the current values of the parameters of the right-hand screen.
Start Remote Control. Replace the output signal of the ECU sensors through your computer.
Important information: Remote control operation method, please refer to the following
'Input Variables' parameter is selected to send the input to the ECU.
'When you click , then select 'Input Variable' is sent to the right of the screen.
'Output Variables' output parameters are analyzed in ECU.
Clicking the and then select 'Output Variable' is sent to the right of the screen.
Click on 'View Current Value' You can see the current value of the selected parameter.
Each puts the value of the apportioned value of the selected parameter in the 'Input' field.
Press the remote control starts to see the results of the selected value.
Press the remote control still shows the input value of the engine.
Register machine ID
The ECU can record the ID number and the engine of the equipment. After the ECU reprogram,
engine number and the machine serial number is not saved. You must save the engine number
and the machine serial number.
“Select in communication”.
View all : press the 'view all' button to see all the EOL data.
.CUID_D_DSID_CUC : Record the serial number and engine surfaces.
.CUID_D_VIN_CUC : Make a note of the machine serial number.
.CUID_D_VMS3_CUC : Record the machine model number.
“Apply” : To apply the new values to the ECU.
“Open selection” : Open the data items stored in the computer.
“Save selection” : Save the selected data items.
Open. Open the value and specific service data previously stored.
Save. Save the data to a specific value.
Change the Data. Check the EOL to modify data values. “√” appears on the entry of ‘SEL’. Insert
a new value in the 'Value' column, click "Apply". The new value is stored in the ECU. The valid
input values, click the "Disconnect ECU" and wait for a few minutes. The new value is shown on
the ECU information.
Warning: Always, when you change the EOL data and ECU reprogram the engine must be
stopped. (The key is 'On' status)
Software Updates (for ECU)
Choose File. Select the ECU re-map file in a notebook or rework program, File is available from
Doosan.
Transferring files. Install the ECU map file, you can check the progress of the installation program.
Completing the installation (100%). "Communication end" is displayed, the installation is
complete.
Important information: After confirming the progress of the following conditions More
reprogramming.
Ensure that the laptop battery has sufficient.
If the proper transmission of the file fails, -> If the ECU is damaged, otherwise the
engine can no longer operate and must be replaced.
After starting the engine again NDMS number, machine serial of the ECU using EOL, you
must re-enter.
ECU Info
The ECU can check the correct device to perform the test with the (hardware, software, machine
ID).
The type of data provided
VIN: Serial number
Engine Type: Surface / engine numbers
The last used user: The ID number of the last recorded user data change
Software Version: Software Version Displays
Data set: Show map file versions
Program data: EOL Displays the last modified data, If the data has not changed is
displayed as blank. Engine test data
Engine test data show
Model Number: Machine Model Number
Diagnosis of engine TIER4 Interim
Fault code
When you start the engine diagnostics, engine fails to display the error code and message.
Important information: Until deleted by the user of the NDMS All messages remain in the ECU
memory. 'Current' error message can not be deleted. "Past" error message may be deleted.
Warning: Failure history Delete history is available only to relevant authorized users gateun. Users
who do not have the right to provide its functionality.
Freeze Frame. Click the freeze frame. You can view the environmental conditions when the error
occurred.
Help. Click on the Diagnostic Trouble Code Manual is open. You can see the details of the error, It
will recommend a method for engine repair / check / check.
Data Monitoring
Data monitoring can determine the sensor and the data values of the service engine Also, you
can check the status of sensors and switches in the electrical components.
Data Group
Select the service data by selecting the Download menu
You can choose the (All data, Start data, injector data, voltage data, fuel pressure
DPM After treatment dat).
Show selection
Select the check Sel to select a rectangle placed within the first service.
It is shown in only selected parameters (service data) screen.
Snapshot
Snapshots can be recorded and displayed for the engine operating conditions.
Graph
It shows the value of each service data selected by the graph.
Save
Service Data name, parameter name, value and unit are stored in the current file.
Shut-Off Test
Shut-off test is to determine the variation in the state of each injector.
Testing Procedure:
Down menu by selecting the select cylinder
Click the Start button,
Compared to the other cylinders
Input/Output Test
This is to control the actuators of the engine part and, You can check the condition of the
actuator.
Status Box. The contents of the status box, check the status of the engine is operating.
Engine : Engine on/Off
IG.Key : ignition key on/off
Control : Activation
Value : Input value
MIN/MAX : Range
Results box. The contents of the box are the output results after the test engine.
Boost pressure actuator Test Procedure.
A. This test can tell the VGT normal operation.
B. Select the boost pressure actuator test.
C. Press the Start button.
D. Enter a value in the 'value' box.
E. Check the VGT shaft with the naked eye.
F. Click Return to ECU.
Important information: If (PRV values, Ash, DPF value) must be changed, click the button below.
If you do not click on the Change button and components, The ECU continues to calculate the
extent of the part, and, Part 3 is a fault code will be generated.
Transferring files. Install the ECU map file, you can check the progress of the installation program.
Important note: After confirming the progress of the following conditions More reprogramming.
Ensure that the laptop battery is sufficient.
If the proper transmission of the file fails And the ECU is damaged or otherwise
need to be replaced if the engine can no longer operate.
After starting the NDMS again using EOL engine number, equipment serial of the ECU
must be re-entered.
Reprogramming Procedure.
Map file selected in the notebook.
Press the Start version, you can check the progress.
ECU Info
The type of data provided
ECU Hardware numbers: ECU Hardware Version Displays
VIN Data ID: Displays the vehicle serial number
ECU Software Version: ECU Software Version Displays
Engine Type: Surface / engine numbers
Program Data: EOL Display data modification date, Be blank if no data is changed
Map Version: Show Map Version
Model No. Machine model number
Trouble Shooting
Important information: When contact your representative if you pass as the error codes below