CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
300 200
145 117
230 270
700
500
3150
670
670
100
100
117
220 2760 145 220
315
220
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
2405 3700
670
700
105 125
30
100
100
175 200
175 200
300
100
250
115
230
10717890
1905 375 20 3535
R4
8 140
363
162
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
230 270
500
3700 2405
670
700
125 105
30
100
100
175 200
175 200
300
100
250
115
230
90178107
3535 20 375 1905
R4
8 140
363
162
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
670
700
100
100
115 7960 115
300 200
315
220
700
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
415
200 300
500
220
85 R4
8 128
363
440
1200
350 350
300 200
1200
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-104 -
10/Oct/2023 6:29:26 PM USER
7460
1580 4300 1580
1580 4300 1580
730 600 600 600 600 600 600 600 600 600 600 730
115 115
200 300
415
500
220
85
R4
128
1200
440
350 350
300 200
1200
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-104A -
10/Oct/2023 6:29:31 PM USER
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
250 250
250
200 175
550
363
250
75
200 155 755 250
20
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
250 250
250
200 175
550
250
75
363
250 755 155 200
20
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
730 600 600 600 600 600 600 600 600 600 600 730
115 96
230 270
500
250
250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
730 600 600 600 600 600 600 600 600 600 600 730
96 115
230 270
500
175 200 175
250
200 155 830 125
20
175
250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
1885
175 200
250 1385 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
1885
175 200
250 1385 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115 115
230 270
500
490
220
R4 140
8 128
440
363
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115 115
230 270
500
490
220
R4 140
8 128
440
363
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
114178 190108
300 300
2335 590 1710
115 300 300 90
175 200 175
R4 140
8 128
490
440
363
220
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
45N=920 L
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 2.5ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 2.3 Ton 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-110 -
10/Oct/2023 6:30:26 PM USER
4635
815 3005 815
815 3005 815
430 600 575 700 700 600 600 430
90 115
230 270
500
108190 178114
300 300
1710 590 2335
90 300 300 115
175 200 175
R4 140
8 128
490
440
363
220
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
45N=920 L
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 2.5ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 2.3 Ton 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-110A -
10/Oct/2023 6:30:31 PM USER
3260
315
315
815 1630 815
220
270
815 1630 815
363
440
350 350
230 270
500
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-111 A
10/Oct/2023 6:30:36 PM USER
3260
315
315
815 1630 815
220
270
815 1630 815
363
440
350 350
230 270
500
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-111A A
10/Oct/2023 6:30:41 PM USER
7460
730 600 600 600 600 600 600 600 600 600 600 730
115 115
1805 1805
200 300
500
415
220
R4
8 128
240
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-112 A
10/Oct/2023 6:30:46 PM USER
7460
730 600 600 600 600 600 600 600 600 600 600 730
115 115
1805 1805
200 300
500
415
220
R4
8 128
240
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-112A A
10/Oct/2023 6:30:51 PM USER
7460
1528 4505 1428
1528 4505 1428
1042 600 600 600 600 688 600 600 600 600 500 430
85 115
500
500
75 7260 125
300 300
175 200 175
200 175
175
100
100
3680 200 3580
115
200 3380 200
550
950
85
3505
575
300 115
300
200
100
100
135
270
175 200 3580
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
500
125 7260 75
300 300
175
200 175
100
3580 200 3680
115
200 3380 200
950
550
85
3505
575
115 300
300
200
100
100
135
270
3580 200 175
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
258 242
500
500
250 250
200
250 1660 20 20 5110 250
96 300 300 300 115
94178 190 88
200
325
110
300
270
96
135
94
3580 200 175
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
258 242
258 242
500
500
250
250
200
250 5110 20 20 1660 250
115 300 300 300 96
94178 190 88
200
175 200 175
110
3480 200 3580
96
700
200 3380 200
3305
325
110
300
270
96
135
94
175 200 3580
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
2460
175 200
250 1960 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115
258 242
258 242
500
2460
175 200
250 1960 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
270
815 1630 815
363
440
350 350
230 270
500
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-117 A
10/Oct/2023 6:31:36 PM USER
3260
315
815 1630 815
270
815 1630 815
363
440
350 350
230 270
500
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-117A A
10/Oct/2023 6:31:41 PM USER
4660
115 115
230 270
500
490
220
R4 140
8 128
440
363
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115 115
230 270
500
490
220
R4 140
8 128
440
363
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
100
395
395
1032
300
300
1310
710
1430
1130
250
300
330
20
125 242
475
3920
2065
250
1930
1655
1032
180
300
110
110
125
175 250
SCALE REF.
SALMIA 9 STOREY BUILDING AT HIDD
08-July-23 / MNM
FILE NO. DRAWING NO. REV. M. CHECKED
KBS-148 BE-119 -
SCALE REF.
SALMIA 9 STOREY BUILDING AT HIDD
08-July-23 / MNM
FILE NO. DRAWING NO. REV. M. CHECKED
258 242
200 300
500
250 250
R4
8 128
240
415
363
258 242
258 242
440
270
500
330
350 350
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
730 600 600 600 600 750 600 600 600 600 600 730
115 115
1805 1805
200 300
500
415
220
R4
8 128
240
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-122 A
10/Oct/2023 6:32:11 PM USER
7610
730 600 600 600 600 750 600 600 600 600 600 730
115 115
1805 1805
200 300
500
415
220
R4
8 128
240
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-122A A
10/Oct/2023 6:32:16 PM USER
7610
1528 4655 1428
1528 4655 1428
5480 600 600 500 430
115 115
380
162
500
500
140
440
125 7410 75
300
315
120
250
115
100
128 8
R4
175
175
250
300
363
300
5410 200 1960
350 350 20 20
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
380
162
500
500
140
440
75 7410 125
300
315
120
175 200 175
250
115
100 R4
175 8 128
175
250
300
363
300
1960 200 5410
20 20 350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
162
342
342
600
258
258
140
242
250 300 250
440
20
250
200 1510 250
115
100 300 315
120
250
175
250
363
300
300
2060 200 5235 175
20 20 350 350
342
342
258
258
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
342
600
258
258
140
242
250 300 250
20
250
250 1510 200
115
315 300 100
120
250
175 200 175
128 8
R4
175
175
250
363
300
300
175 5235 200 2060
350 350 20 20
342
342
258
258
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
270
440
363
815 1630 815
440
440
2700
258 242
258 242
230 270
500
155 200
20
20
75
175 3085
258 242
258 242
500
330
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-125 A
10/Oct/2023 6:32:41 PM USER
R4
3260 8 128 140
315
270
440
363
815 1630 815
440
440
2700
258 242
258 242
230 270
500
155 200
20
155
75
3085 175
258 242
258 242
500
330
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
6692-55 = 1378
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 5.0ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 3.38 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-125A A
10/Oct/2023 6:32:46 PM USER
3710 315 315
120
270
815 2080 815
815 2080 815
R4
8 128
430 600 600 450 600 600 430
140
363
115 115
440
350 350
258 242
258 242
230 270
500
500 500
440
440
3150
250 3210 250
258 242
258 242
500
330
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 2.5 ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-126 -
10/Oct/2023 6:32:52 PM USER
3710 315 315
120
270
815 2080 815
815 2080 815
R4
8 128
430 600 600 450 600 600 430
140
363
115 115
440
350 350
258 242
258 242
230 270
500
500 500
440
440
3150
250 3210 250
258 242
258 242
500
330
250 250
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
3. Clear cover of reinforcement to be 40mm UNO. Frimeda 2.5 ton 2 08-July-23 / MNM
Bending Sch. Bending Rev. Element Wt. Panel Nos. 4. Please ensure that mould is 100% leak free. Rd 16 Mm Anchor Sockets (hdg) 2 FILE NO. DRAWING NO. REV. M. CHECKED
5. For finishes refer product standard Section 16.02.
Yes 1 CAST IN PARTS NO. MARK DATE BY REVISION SIGN KBS-148 BE-126A -
10/Oct/2023 6:32:57 PM USER
4660
115 115
230 270
500
315
220
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
115 115
230 270
500
315
220
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
175 200
250
115
100
2335 20 375 3280
315
250
380
115
120
162
100
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER
175 200
175 200
250
115
100
3280 375 20 2335
315 380
250
115
120
162
100
R4
8 128 140
363
440
350 350
SCALE REF.
CONCRETE MIX/QUANTITY IN LITRES NOTES SALMIA 9 STOREY BUILDING AT HIDD
LAYER 1 LAYER 2 LAYER 3 LAYER 4 1. Tolerances as per quality handbook.
2. 'C' = 10x10 and 'C1' = 20x20 chamfer. MOULD/RFT ARRANGEMENT DATE / DESIGNER