You are on page 1of 9

AS 1012.3.

4—1998 (Reconfirmed) 2014-10-24

STANDARDS AUSTRALIA

RECONFIRMATION
OF
AS 1012.3.4—1998
Methods of testing concrete
Method 3.4: Determination of properties related to the consistency of concrete—
Compactibility index

RECONFIRMATION NOTICE

Technical Committee BD-042 has reviewed the content of this publication and in
accordance with Standards Australia procedures for reconfirmation, it has been determined
that the publication is still valid and does not require change.

Certain documents referenced in the publication may have been amended since the original
date of publication. Users are advised to ensure that they are using the latest versions of
such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.

Approved for reconfirmation in accordance with Standards Australia procedures for


reconfirmation on 9 September 2014.

The following are represented on Technical Committee BD-042:

AUSTROADS
Australian Chamber of Commerce and Industry
Cement Concrete and Aggregates—Concrete
Concrete Institute of Australia
National Association of Testing Authorities Australia
The University of New South Wales
University of Technology Sydney
Victorian Construction Materials Laboratory
NOTES
1 AS 1012.3.4 — 1998
Reconfirmed 2014

Australian Standard ™
Methods of testing concrete

Method 3.4: Determination of properties


related to the consistency of
concrete—Compactibility index

PREFACE

This Standard was prepared by Standards Australia Committee BD/42, Methods of Testing
Concrete, to supersede, in part, AS 1012.3 — 1983. This method is one of a series
applying to the sampling and testing of concrete.

METHOD

1 SCOPE This Standard sets out the method for determining the compactibility index,
for concrete, where the expected slump is less than 10 mm and the nominal size of
aggregate does not exceed 40 mm.
NOTE: This Standard may involve hazardous materials, operations, and equipment. This
Standard does not purport to address all of the safety problems associated with its use. It is the
responsibility of the user of this Standard to establish appropriate safety and health practices
and determine the applicability of regulatory limitations prior to use.

2 REFERENCED DOCUMENTS The following documents are referred to in this


Standard:
AS
1012 Methods of testing concrete
1012.1 Method 1: Sampling of fresh concrete
1012.2 Method 2: Preparation of concrete mixes in the laboratory
1012.8 Method 8: Method for making and curing concrete compression, indirect
tensile and flexure test specimens in the laboratory or in the field.
1289 Methods of testing soils for engineering purposes
1289.5.1 1 Method 5.1.1: Soil compaction and density tests — Determination of the dry
density/moisture content relation of a soil using standard compactive effort

3 PRINCIPLE Concrete is placed into a mould and compacted by a rammer. The


amount of consolidation is expressed as a compactibility index.

4 APPARATUS
4.1 Mould A standard cylinder mould (300 mm high × 150 mm dia.) complying with
AS 1012.8, with a removable collar 150 mm high mounted above it, which shall have the
same internal diameter as the cylinder.

COPYRIGHT
AS 1012.3.4 — 1998 2

4.2 Rammer A steel rammer with a 50 mm diameter face and a drop mass of 2.7 kg,
equipped with a suitable device to control the height of drop to a free fall of 300 mm.
One suitable design of hand apparatus is shown in Figure 1 and Table 1, and is identical
to the standard rammer specified in AS 1289.5.1.1.
4.3 Scoop The scoop shall be made from non absorbent material not readily attacked
by cement paste and suitable for taking increments of concrete.
NOTE: The scoop should be large enough to accommodate the maximum size of aggregate in
the concrete, of sufficient size to obtain a representative sample but small enough to restrict
mass of scoopful of concrete to a size that is able to be handled.
4.4 Ruler An appropriate steel ruler is required.

5 SAMPLING
5.1 Field Sampling For concrete sampled in the field, the test sample shall be obtained
in accordance with the requirements of AS 1012.1.
5.2 Laboratory Sampling For concrete made in the laboratory, the test sample shall
be prepared in accordance with AS 1012.2.

6 PROCEDURE The test shall be carried out as follows:


(a) For concrete sampled in the field commence the test immediately following the
completion of mixing the test sample. For concrete prepared in the laboratory
commence test in accordance with AS 1012.2.
(b) Ensure that the internal surface of the standard cylinder mould is clean and free
from set concrete.
(c) Moisten the internal surface of the cylinder by wiping with a damp cloth
immediately before commencing each test.
(d) Firmly fix the 150 mm extension to the top of the cylinder mould, and place the
entire apparatus on a level rigid surface free from vibration or shock.
(e) Place the concrete to be tested gently into the mould and overfill the standard
cylinder mould. As each scoopful of concrete is being placed, move the scoop in
contact with and around the rim of the collar. This is to assist symmetrical
distribution of the concrete within the mould.
(f) Remove the collar then strike off the excess concrete remaining above the top of the
cylinder by moving a trowel, with blade horizontal, across the top of the mould.
(g) Replace the collar and compact the concrete remaining in the standard cylinder
mould with 100 blows of the rammer, working to a regular repetitive pattern to
ensure uniform compaction.
(h) Remove the collar and determine the mean drop in surface level from not less than
three evenly spaced measurements.
(i) Complete the overall procedure within 30 min. from time of sampling.

7 COMPACTIBILITY INDEX The compactibility index expressed to the nearest


whole number, shall be calculated from the following equation:
300 x
Compactibility index = ...7
3
where
x = mean drop in surface level due to compaction, in millimetres.

COPYRIGHT
3 AS 1012.3.4 — 1998

8 RECORDS The following information shall be recorded:


(a) Identification of the concrete.
(b) Job site or laboratory where tested.
(c) Date and time of test.
(d) Compactibility index.
(e) Mean drop in surface level due to compaction, in millimetres.
(f) Identification of testing operator.
(g) Reference to this Standard, i.e. AS 1012.3.4.

9 REPORT In the event of a report being prepared, the following information shall be
included:
(a) Identification of the concrete.
(b) Date and location of test.
(c) Compactibility index.
(d) Reference to this Standard, i.e. AS 1012.3.4.
(e) Such other information contained in the sampling records (see AS 1012.1) as may
be requested.

COPYRIGHT
AS 1012.3.4 — 1998 4

PARTS LIST AND TYPICAL DIMENSIONS


1 Handle Ø 30 × 3 thick, black low-carbon steel tube
90 long
2 Rod Ø 19 bright low-carbon steel rod
3 Guide washer 5 low-carbon steel flat Ø 40
4 Tube Ø 26 × 3.2 thick, black low-carbon steel tube 90
long
5 Frame washer 5 low-carbon steel flat Ø 75
6 Guides Ø 8 low-carbon steel rods — 3 no.
7 Full ring 25 × 3 low-carbon steel flat
8 Washer pad Ø 45 leather
9 Rammer Ø 50 bright low-carbon steel bar
10 Part ring 25 × 3 low-carbon steel flat
NOTES:
1 This design has been found satisfactory, but alternative designs and materials can be
employed provided that the essential requirements in Table 1 are met. The design of
the hammer should permit the hammer to fall freely through the specified drop height.
The design of the hammer should ensure that there is a clearance not greater than
6 mm between the wall of the mould and the hammer during use.
2 The thickness of the leather washer (Part 8) may be adjusted to give the specified
height of fall for the rammer.
3 The head of the rammer (Part 9) may be drilled and tapped to fit Part 2.
4 The mass of the moving parts may be adjusted by drilling deeper into Part 9.
5 Tolerances indicated are for manufacturing purposes.
DIMENSIONS IN MILLIMETRES

FIGURE 1 2.7 KG RAMMER

COPYRIGHT
5 AS 1012.3.4 — 1998

TABLE 1
DIMENSIONS AND TOLERANCES FOR SUITABLE RAMMER

Apparatus Dimension Tolerance

Diameter (round foot), mm 50 ±0.4


Radius (sector foot), mm 74 ±0.5†
Arc of segment (sector foot), degrees 41 ±0.5
2
Area of rammer, mm 1 964 ±31
Drop, mm 300 ±2.0‡
Mass, kg 2.7 ±0.01‡
Energy delivered per blow, J 7.94 ±0.08
3
Energy input, kJ/m 596 ±14
† Either but not both of the tolerances may be exceeded provided that the
tolerance of area is not exceeded. Diameter and radius of arc of segment are
measured 3 mm behind the face of the rammer.
‡ Either but not both of the tolerances may be exceeded provided that the
appropriate tolerance of energy delivered per blow is not exceeded.

COPYRIGHT
AS 1012.3.4 — 1998 8

This Australian Standard was prepared by Committee BD/42, Methods of Testing Concrete. It was approved on behalf of
the Council of Standards Australia on 10 July 1998 and published on 5 September 1998.

The following interests are represented on Committee BD/42:


Association of Consulting Engineers, Australia
Australian Chamber of Commerce and Industry
Australian Pre-mixed Concrete Association
AUSTROADS
Cement and Concrete Association of Australia
Concrete Institute of Australia
CSIRO, Division of Building, Construction and Engineering
National Association of Testing Authorities Australia
University of New South Wales
University of Technology, Sydney

Review of Australian Standards. To keep abreast of progress in industry, Australian Standards are subject to periodic
review and are kept up to date by the issue of amendments or new editions as necessary. It is important therefore that
Standards users ensure that they are in possession of the latest edition, and any amendments thereto.
Full details of all Australian Standards and related publications will be found in the Standards Australia Catalogue of
Publications; this information is supplemented each month by the magazine ‘The Australian Standard’, which subscribing
members receive, and which gives details of new publications, new editions and amendments, and of withdrawn Standards.
Suggestions for improvements to Australian Standards, addressed to the head office of Standards Australia, are welcomed.
Notification of any inaccuracy or ambiguity found in an Australian Standard should be made without delay in order that the
matter may be investigated and appropriate action taken.

Originated as part of AS 1012.3 — 1983.


Revised and redesignated in part as AS 1012.3.4 — 1998.

This Standard was issued in draft form for comment as DR 97438.

© Copyright STANDARDS AUSTRALIA


Users of Standards are reminded that copyright subsists in all Standards Australia publications and software. Except where the
Copyright Act allows and except where provided for below no publications or software produced by Standards Australia may be
reproduced, stored in a retrieval system in any form or transmitted by any means without prior permission in writing from
Standards Australia. Permission may be conditional on an appropriate royalty payment. Requests for permission and information
on commercial software royalties should be directed to the head office of Standards Australia.
Standards Australia will permit up to 10 percent of the technical content pages of a Standard to be copied for use
exclusively in-house by purchasers of the Standard without payment of a royalty or advice to Standards Australia.
Standards Australia will also permit the inclusion of its copyright material in computer software programs for no royalty
payment provided such programs are used exclusively in-house by the creators of the programs.
Care should be taken to ensure that material used is from the current edition of the Standard and that it is updated whenever the
Standard is amended or revised. The number and date of the Standard should therefore be clearly identified.
The use of material in print form or in computer software programs to be used commercially, with or without payment, or in
commercial contracts is subject to the payment of a royalty. This policy may be varied by Standards Australia at any time.

ISBN 0 7337 2155 9 Printed in Australia


This page has been left intentionally blank.

You might also like