3.2.3 Operating Procedure of One-Sided Fin Only either of the fins has failed, i is possib remaining fin only, © stop the failed fin and operate the This operating procedure shall be as follows, (1) If one of the fins has failed to function Properly during the normal operation, stop the failed System in accordance with the : “Stoppin; Procedure in Normal Operation" ‘ in para. 3.1.2 (1), (2) If the failed fin can not be rigged IN, rig it IN, using the Local Control Panel or the Hand Pump. (3) Stopping Procedure of the Failed Fin a. Ensure that the failed fin has been properly rigged IN for stowing and that the Rigging Lock has been securely latched, b. “STOP” the Selector Switch of the Hydraulic Pump Starter for the failed fin. | (4) Actuation of the Normal Fin After stowing the failed fin in accordance with the instructions given in para, (3) above, start to run the normal fin in accordance with the “Normal Operation” in para. 3.1. At this time, the PUMP RUN Indicator Lamp for the failed fin now off duty goes out. Upon the actuation of the normal fin, the PUMP RUN Indicator Lamp for the fin now off duty goes out, and the Alarm Buzzer begins to sound. So, the Buzzer must be reset (muted). 3.2.4 Comeback and Its Operating Procedure of the Failed Fin To return the failed fin to the normal operation after it has been service/repaired, set the Selector Switch of the Hydraulic Pump Starter for the stopped fin, to “REMOTE”, and then, start to run the system in accordance with the “Normal Operation" as detailed in para, 3.3.1. 48 (1) Ensure that the Hydraulic Pump has Stopped, (2) To center the fin to its ZERO Toce Position, change over the Manually operated Directional Valve (DV3) and then, operate the lever of the Manually. (4) After releasing the Rigging Lock Mechanism Operated Directional Valve (DV1) and operate rig the fin OUT/IN. , change over the Manually fe the lever of the Hand Pump to (5) Upon completion of the fin Rigging OUT/IN, change over the Manually Operated Directional Valve (DV2) and operate the lever of the Hand Pump to lock the Rigging System with the Rigging Lock Mechanism, 49 3.2.6 SS gee Fin Operation Using the Emergency Pump Hydraulic Syste a a a 2 ys 7 for the Normal Operation should happen to fail, the centering tothe Position and Rigging OUTIIN of the fin ae avilable, using the Emergency Pump, The fin operating procedure using the Emergency Pump is given below: (1) Ensure that the Hydraulic Pump has stopped, (2) Start Emergency Pump by PushStar button of Starter for Emergency Pump Unit, (3)_ To center the fin tits ZERO position, eh ange over the Manually operated Directional Valve (DV3) . (4) When the fin has reached a range of within 0:2 ° change over the Manually Operated Directional Valve (DV2) to release the Rigging Lock Mechanism. (©) After releasing the Rigging Lock Mechanism, change over the Manually Operated Directional Valve (DV1) to rig the fin OUTN, (6) Upon completion ofthe fin Rigging OUTVIN, change over the Manually Operated Directional Valve (DV2) to lock the Rigging System with the Rigging Lock Mechanism. (1) Stop Emergency Pump by Push Stop button of Starter for Emergency Pump Unit.

You might also like