Control unit

4. Adjustment of current control circuit

4-3. SICOS 60 (2) Setting and adjustment (FB-60)


Basically, SICOS 60 is the same as SICOS 50, but the 1) Safety monitor symbol (LCD)
following points are different. Make sure that the monitor symbols are set to the
Potentiometer quantity : 5 same parameter of adjustment standards list for
It is possible to adjust back light brightness. FB-60.
Rotary switch quantity : 2 <Setting procedure>
The functions that rotary switches of SICOS 50 had
1. Set rotary switch RS1 to "E".
are done by combinations with two rotary switches,
2. Set (appear) or reset (disappear) each symbol by
[MODE], [UP] and [DOWN] buttons.
pushing , and buttons.
lItem selection : push button
(1) Adjustments and checking lSetting : push button
(FB-60) lResetting : push button

1) Monitor (LCD) "TRAVEL" and "HYD" are set automatically.

Item Checking / Description SAFTY 1 1 1 0 0 0 1 0


1 Symbol Check meeting specifications
Check language with T H S B O L B
2 Language
customer's request R T A O R
Y I
3 Hour meter Check operation A D E T L A A
4 Mode selection Check mode selection is possible V E T D K
E R E
Check meeting with customer's L
5 Option
request
(Table 5-54)
(Fig. 5-56)
2) MPU board
[Caution]
Item Checking / Description
After finishing to set or reset, return rotary switch
1 LED 0 (P12) Light on
RS1 to "0".
2 LED 1 (P5) Light on
3 LED 2 (STP) Light off
4 VR0 (ST) Starting current adjustment 2) Language setting on LCD
5 VR1 (CL) Current limit adjustment Make sure that the correct language is displayed when
6 VR2 (IP) IP voltage adjustment the key switch is turned on.
7 VR3 (LCD) LCD contrast adjustment
(Refer to the following table.)
Back light brightness
8 VR4 (CFL) <Setting procedure>
adjustment
9 RS0 Truck model selection Six languages can be selected by rotary switch RS1-7
10 RS1 Monitor selection (SW13).
(Table 5-55)
Display when turning key
Language SW13
switch on
Japanese OK [0]
English MONITORING OK [1]
French CONTROLEUR OK [2]
German UBERWACHUNG OK [3]
Spanish MONITOR OK [4]
Dutch MONITOR OK [5]
(Table 5-57)

182
Control unit
4. Adjustment of current control circuit

l MPU board
P12 (L0) : Turns on when 12V power supply is normal.
P5 (L1) : Turns on when 5V power supply is normal.
STP (L2) : Turns on when microprocessor is stuck.
ST (VR0) : Start current adjustment
CL (VR1) : Current limit adjustment
IP (VR2) : Sensitivity adjustment of plugging current detection
LCD (VR3) : LCD contrast adjustment
CFL (VR4) : Back light brightness adjustment
IP voltage check terminal
(RS0) : Model selection
(RS1) : Monitor selection

Pin locations for connectors

(Fig. 5-58)

* Pin locations for connectors are shown from insertion side of pins.

183
Control unit
4. Adjustment of current control circuit

(3) Functions for RS1


Position Function Remarks
0 Normal monitor Hour meter display
SW1 Plugging brake 0 F (strong)
1
SW2 Regenerative brake 0 F (strong)
SW3 Foot brake regeneration 0 F (strong)
2
SW4 Overdrive speed 0 F (fast)
SW5 Maximim lift speed 1 0 F (fast): for travel speed 10-15 km/h
3
SW6 Maximim lift speed 2 0 F (fast): for travel speed 5-10 km/h
SW7 Maximim lift speed 3 0 F (fast): for travel speed 0-5 km/h
4
SW8 Tilt speed 0 F (fast)
SW9 Attachment 1 speed 0 F (fast)
5
SW10 Attachment 2 speed 0 F (fast)
SW11 Not used
6
SW12 Not used
SW13 Language selection Six (6) language
7
SW14 Not used
8-B Internal memory
C I/O check
D Option setting
E Monitor symbols "STEER", "BATT", "OIL", "LOAD", "BRAKE"
F Hour meter display for errors
(Fig. 5-59)

* Each setting parameter should be followed by the adjustment standards list for FB-60.