You are on page 1of 94
0/2017 16:01:40 de uso excluswo de ABB LTDA- OSASCO Arquivo de mpressao gerado em 1: Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” NORMA BRASILEIRA ABNT NBR 17505-4 Terceira edigaio 09.07.2015 Valida a partir de (09.08.2015 Verso corrigida 20.07.2015 Armazenamento de liquidos inflamaveis e combustiveis Parte 4: Armazenamento em recipientes e em tanques portateis até 3 000 L Storage of flammable and combustible liquids Part 4: Storage containers and portable tanks up to 3.000 L ICS 75.160; 75.200 ASSOCIACAO BRASILEIRA. DE NORMAS. TECNICAS ISBN 978-85-07-05682-9 Numero de referéncia ABNT NBR 17505-4:2015 84 paginas © ABNT 2018 Arquivo de mpressdo gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 © ABNT 2015 ‘Todos 0s direitos reservados. A menos que especificado de outro modo, nenhuma parte desta pubicacéo pode ser reproduzida ou utlizada por qualquer meio, eletrénico ou mecéinico,incluindo fotocépia e microflme, sem permissao por escrito da ABNT, ABNT Av Treze de Maio, 13 - 28° andar 20081-901 - Rio de Janeiro - Fu Tel: + 55.21 9974-2300 Fax: +55 21 9974-2346 abnt@abnt.org.or wwabntorg br © ABNT 2018 - Todos 08 direitos reservados Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Sumario Pagina Prefacio Introdugao. 1 Escopo 2 Referéncias normativas. 3 Termos e definicées. 4 Requisitos gerais 5 Recipientes aceitaveis 6 (*) Armarios (gabinetes) para armazenamento de liquidos inflamaveis 7 Quantidades maximas permitidas por area controlavel de armazenamento TA Limites em estabelecimentos em geral 7.2 Limites em estabelecimentos especiais 8 Area controlavel de armazenamento. 9 Requisitos para construcao. 10 Protegao contra incéndio 10.4 Armazenamento protegido 10.2 Protecao manual contra incéndit 1 Sistemas elétricos. 12 (*) Contengao, drenagem e controle de derrames e vazamentos.... 13 VentilagdO verse 14 Controle de exploso. 15 16 Envasamento, manuseio e utilizagao de liquidos em areas de armazenamento. 17 Armazenamento externo de liquids .. 18 Armazenamento de liquidos em recipientes — Estabelecimentos comerciai 18.1 Requisitos gerais 18.2 Areas controlaveis de armazenamento.. 18.3 Restricdes especificas. 18.4 Requisitos construtivos. 18.5 Protecao contra incéndio 18.6 Sistemas elétricos. 18.7 Contengao, drenagem e controle de derrames e vazamentos.. 18.8 Ventlagd0..nnssnss = 18.9 Separagao de materiais incompativei: 18.10 Envasamento, manuseio e utilizagao de Iiquides em estabelecimentos comerciais 15 18.11 Armazenamento externo de liquidos .. 19 Armazenamento de liquidos em recipientes - Estabelecimentos industriais 19.4 Requisitos gerais 20 Armazenamento de liquidos em recipientes — Estabelecimentos de armazenamento 16 20.1 Requisitos gerais... eee 20.2 Quantidades e alturas maximas permitidas de armazenamento.... 20.2.1 Salas de armazenamentos de liquidos © ABNT 2015 - Todos 08 direitos reservados i Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 20.2.2 20.3 20.4 20.5 20.6 20.7 20.8 20.9 20.10 20.11 20.12 20.13 21 2a4 21.2 24.24 21.2.2 21.3 21.4 21.5 21.6 21.7 21.8 21.9 22 22.4 22.2 22.3 22.4 23 23.1 23.2 24 24.1 24.2 24.3 24.3.1 24.3.2 24.4 24.44 iv ‘Armazém de liquids . Areas controlaveis de armazenament Armazéns gerais.. Requisitos construtivos. Protecao contra incéndios Sistemas elétricos. Contengao, drenagem e controle de derrames/vazamentos.. Ventilacao. Controle de explosao. Separacao de materiais incompativeis Envasamento, manuseio e utilizagao de liquidos em areas de armazenamento .....20 Armazenamento externo de liquidos Armazenamento de liquidos em recipientes — Edificacdes destacadas e desprotegidas. Requisitos gerals Quantidades maximas permitidas e alturas méximas de armazenamento..... Requisitos construtivos Protecao contra incéndio.. Sistemas elétricos. Contengao, drenagem e controle de derrames e vazamento: Ventilacao. Controle de explosao. ‘Separacdo de materials incompativeis Envasamento, manuseio e utilizagao de liquidos em areas de armazenamento..... Armazenamento externo de liquidos (‘) Cubiculos para armazenamento de produtos perigosos .. Requisitos gerais Projeto e construcao de cubiculos para armazenamento de materials perigosos . Locais selecionadios para instalagao de cubiculos para armazenamento de materiais perigosos...... Requisitos para o armazenamento. Armazenamento externo Requisitos gerais Armazenamento externo préximo a uma edificagao (*) Protecao automatica contra incéndios em armazenamentos internos. Requisitos gerais Sistemas de protecao contra incéndios por chuveiros automaticos (sprinklers) de agua ou de espuma... Critérios para projeto de sistemas de protecao contra incéndios .. Geral. Critérios especificos para projeto (*) Esquemas para projetos de sistemas de protecdo contra incéndios Esquema “A” de protecao contra incéndio. © ABNT 2018 - Todos 08 direitos reservados Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Esquema “B” de protecao contra incéndio. Esquema “C” de protecao contra incéndio. Leiautes para sistemas de chuveiros de niveis intermediarios para a Tabela A.20...38 Suprimento de agua Contengao, drenagem e controle de derrames e vazamentos.. 24.7 Outros sistemas de protecao automatica contra incéndios... Bibliografia.. ‘Anexos ‘Anexo A (normativo) Tabelas e figuras Anexo B (informativo) Material explanatério Figuras Figura A.1 — Viscosidade versus concentracao porcentual em massa de componente inflamavel ou combustivel. Figura A.2 - Arvore de decisao para o critério de protegao para recipientes metalicos contendo liquidos misciveis e nao misciveis em agua — Inflamavel e combustivel..56 Figura A.3 - Arvore de decisao para o critério de protegao para recipiente nao metalico contendo liquidosmisciveis e nao misciveis em agua — Inflamavel e combustivel...57 Figura A.4 — Arvore de decisao para o critério de protecdo contra fogo para Iiquidos inflamaveis e combustiveis misciveis em agua contido em recipientes ndo metalicos.. Figura A.5 ~ Contengao de derramamentos e controle de dispersao de liquidos em areas de armazenamento protegido: Figura A.6 — Lelaute de chuveiros automaticos para uma estrutura-suporte de fileira unica Esquema de projeto “ Figura A.7 — Lelaute de chuveiros automaticos para uma estrutura-suporte de fileira dupla — Esquema de projeto “A” Figura A.8 - Leiaute de chuveiros automaticos para uma estrutura-suporte de multiplas fileiras — Esquema de projeto “A’ Figura A.9 — Leiaute de chuveiros automaticos para uma estrutura-suporte de fileira unica Esquema de projeto “B” — Chuveiros no centro da estrutura Figura A.10 — Leiaute de chuveiros automaticos para estrutura-suporte de fileira nica — Esquema de projeto "B” — Chuveiros voltados para a estrutura..... Figura A.11 — Leiaute de chuveiros automaticos para estrutura-suporte de fileira dupla— Esquema de projeto “B” Figura A.12 — Leiaute de chuveiros automaticos para estrutura-suporte de fil — Esquema de projeto“C” Figura A.13 — Leiaute de chuveiros automaticos para estrutura-suporte de fileira dupla — Esquema de projeto " Figura A.14 — Lelaute de chuveiros automaticos para estrutura-suporte de multiplas fileiras — Esquema de projeto “C” 55 © ABNT 2015 - Todos 08 direitos reservados v Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Figura A.15 — Leiaute de chuvelros automaticos para estrutura-suporte de fileira dupla — Esquema de projeto “G” Figura A.16 — Leiaute de chuveiros automaticos para estrutura-suporte de fileira dupla — Esquema de projeto “I’- Opcao # 1.. Figura A.17 — Leiaute de chuveiros automatics para estrutura-suporte de fileita dupla ~ Esquema de projeto “I” — Opcao # 2 Figura A.18 — Leiaute de chuveiros automatics para estrutura-suporte de fileira dupla — Esquema de projeto “H" — Op¢do # 1 Figura A.19 - Leiaute de chuvelros automaticos para estrutura-suporte de fileira dupla — Esquema de projeto “H” - Opcao # 2 Figura A.20 - Esquema geral para controle de derramamentos de liquidos em atmazéns......74 Figura A.21 — Vista em planta do controle deliquidos em armazén: Figura A.22 — Detalhes do projeto de drenagem de caneletas . Figura A.23 — Arranjo tipico de drenos de piso. Figura A.24 — Detalhes de purgador selado por liquido. Figura B.1 - Exemplos das varias areas internas de armazenamento de liquidos .. Tabelas Tabela A.1 - Capacidades maximas permitidas para recipientes, recipientes intermediarios para granel (IBC) ¢ tanques portatels Tabela A.2 - Quantidade maxima permitida de liquidos inflamaveis e combustiveis por érea controlavel de armazenamento. Tabela A.3 - Quantidade maxima permitida - Limites para ocupagées especiais, Tabela A.4 - Projeto e numero de dreas controlaveis de armazenamento Tabela A.5 - Classificagao de resisténcia ao fogo para areas de armazenamento de liquids no interior de edificagées.. Tabela A.6 - Tempo requerido de resisténcia ao fogo para portas corta-fogo. Tabela A.7 - Quantidades maximas permitidas para armazenamento e exposicao em ocupagées comerciais... Tabela A.8 — Quantidade maxima de armazenamento de liquidos em salas internas. Tabela A.9 - Quantidades maximas para armazéns de liquidos sem sistema de protecéo automatica .. Tabela A.10 - Locais selecionados # ve ses sv secon Tabela A.11 - Limitag6es para o armazenamento externo de liquidos em recipientes, em recipientes intermediarios para granel (IBC) e em tanques portateis Tabela A.12 — Conversao dos valores do fator K.. Tabela A.13 - Criterios de projeto para protecao por chuveiros autométicos de estruturas- suporte simples ou duplas de liquidos em recipientes metalicos, recipientes intermediarios para granel metélicos e tanques portateis metélicos Tabela A.14- Critérios de projeto para protecao por chuveiros automaticos de armazenamento paletizado e empilhado de liquidos em recipientes metélicos, recipientes intermediarios para granel metélicos e tanques portateis metalicos vi © ABNT 2018 - Todos 08 direitos reservados Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Tabela A.15 — Critérios de projeto para protecdo por chuveiros automaticos de espuma de estruturas-suporte simples ou duplas armazenando liquidos em recipientes metalicos, tanques portateis metalicos e recipientes intermediarios para granel metalicos.. Tabela A.16 — Critérios de projeto para protegao por chuveiros autométicos de espuma de armazenamento paletizado ou empilhado de liquidos em recipientes metélicos, em tanques portateis metélicos e recipientes intermedidrios para granel metalicos..47 Tabela A.17 — Critérios de projeto para protecao por chuveiros automaticos de estruturas- suporte de fileiras simples, duplas ou multiplas para o armazenamento de liquide de classe Ill B Tabela A.18 - Critérios de projeto para protecdo por chuveiros automaticos de recipientes metilicos armazenados em prateleiras .. Tabela A.19 - Critérios de projeto para protecao por chuveiros autométicos de estruturas- suporte simples ou duplas armazenando liquidos misciveis em agua em recipientes de vidro ou de plastico .. 49 Tabela A.20 - Critérios de projeto para armazenamento de liquidos em estruturas-suporte de fileiras simples e duplas para recipientes metélicos do tipo com alivio de pressao paletizados. Tabela A.21 - Critérios de projeto para protecdo por chuveiros automaticos de armazenamento paletizado de liquidos de classes IIe Ill em recipientes intermediarios para granel, rigidos e nao metalicos Tabela A.22 — Critérios de projeto para protecdio por chuveiros automaticos de armazenamento em estruturas-suporte de fileira simples ou dupla de liquids de classe Il ¢ Ill em recipientes intermediarios para granel, rigidos e nao metalicos aprovados ... Tabela A.23 - critérios de projeto para protecdo por chuveiros autométicos para armazenamento de resinas de poliéster insaturado, paletizado ou empilhado, em recipientes metélicos. Tabela A.24 - Critérios de projeto para protecdo por chuveiros automaticos para armazenamento paletizado ou empilhado de recipientes em plastico ou vidro contendo liquidos misciveis Tabela A.25 - Arranjos de armazenamentos para proteger pilhas paletizadas ou sélidas de liquidos armazenados em recipientes e em tanques portatei Tabela A.26 - Arranjos de armazenamento para estruturas-suporte protegidas armazenando liquidos em recipientes e em tanques portdteis Tabela A.27 — Recipientes metalicos dos tipos com alivio comum e sem alivio .. © ABNT 2015 - Todos 08 direitos reservados i Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Prefacio A Associacao Brasileira de Normas Técnicas (ABNT) € 0 Foro Nacional de Normalizacao. As Normas Brasileiras, cujo contetido é de responsabilidade dos Comités Brasileiros (ABNT/CB), dos Organismos de Normalizacao Setorial (ABNT/ONS) e das Comissdes de Estudo Especiais (ABNT/CEE), so elaboradas por Comissdes de Estudo (CE), formadas pelas partes interessadas no tema objeto da normalizacdo. Os Documentos Técnicos ABNT sao elaborados conforme as regras da Diretiva ABNT, Parte 2 A ABNT chama a atencao para que, apesar de ter sido solicitada manifestagao sobre eventuais direitos de patentes durante a Consulta Nacional, estes podem ocorrer ¢ devem ser comunicados @ ABNT a qualquer momento (Lei n® 9.279, de 14 de maio de 1996). Ressalta-se que Normas Brasileiras podem ser objeto de citagao em Regulamentos Técnicos. Nestes casos, os Orgaos responsaveis pelos Regulamentos Técnicos podem determinar outras datas para exigéncia dos requisitos desta Norma, independentemente de sua data de entrada em vigor. A ABNT NBR 17505-4 foi elaborada pelo Organismo de Normalizagao Setorial de Petréleo (ABNT/ONS-034), pela Comissao de Estudo de Distribuicéo e Armazenamento de Combustiveis (CE-34:000.004). O Projeto circulou em Consulta Nacional conforme Edital n® 08, de 22.08.2012 a 22.10.2012. O seu Projeto de Emenda circulou em Consulta Nacional conforme Edital n? 03, de 20.03.2015 a 18.05.2015 Esta Norma 6 baseada na NFPA 30:2012. Esta terceira edigdio incorpora a Emenda 1, de 09.07.2015, e cancela ¢ substitui a edigao ant (ABNT NBR 17505-4:2013). Esta verso corrigida da ABNT NBR 17505-4:2015 incorpora a Errata 1, de 20.07.2016. A ABNT NBR 17505, sob 0 titulo geral “Armazenamento de Iiquidos inflamaveis e combustiveis’, tem previsdo de conter as seguintes partes: — Parte 1: Disposigées gerais; — Parte 2: Armazenamento em tanques, em vasos e em recipientes portateis com capacidade superior a 3.000 L; — Parte 3: Sistemas de tubulagées; — Parte 4: Armazenamento em recipientes e em tanques portateis até 3 000 L; — Parte 5: Operacées; — Parte 6: Requisitos para instalagdes e equipamentos elétricos; — Parte 7: Protegao contra incéndio para parques de armazenamento com tanques estacionérios. Nesta parte da ABNT NBR 17505, onde aparecer (") apés 0 ntimero ou a letra que designa uma seeao, subsepao ou pardgrafo, significa que existe um material explanatério, que pode ser encontrado no Anexo B. vil © ABNT 2018 - Todos 08 direitos reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 © Escopo desta Norma Brasileira em inglés é o seguint Scope This Part of ABNT NBR 17505 shall apply to the storage of flammable and combustible liquids in: a) drums or other containers that do not exceed 450 L individual capacity; b) portable tanks that do not exceed 3 000 L individual capacity; c) intermediate bulk containers that not exceed 3 000 L. To limited transfer of liquids incidental thereto. To overpack drums when used for temporary containment of containers that do not exceed 230 L capacity. Such overpack containers shall be treated as containers as defined in 3.91 to 3.96 of ABNT NBR 17505-1:2013 Shall apply the prescritions of ABNT NBR 17505-2 for portable tanks which individual capacity exceeds 3000 L. This Part of ABNT NBR 17505 shall not apply to the following: a) containers, intermediate bulk containers, and portable tanks that are used in operations areas, as covered by ABNT NBR 17505-5; b) liquids in the fuel tanks of motor vehicles, aircraft, boats, or portable or stationary engines; c) beverages where packaged in individual containers that do not exceed 5 L capacity; d) medicines, foodstuffs, cosmetics, and other consumer products that contain not more than 50 % by volume of water-miscible flammable or combustible liquids, with the remainder of the product consisting of components that do not burn and where packaged in individual containers that do not exceed 5 L capacity; ©) liquids that have no fire point when tested in accordance with ABNT NBR 11341, up to the boiling point of the liquid or up to a temperature at which the liquid shows an obvious physical change; 1) liquids with a flash point greater than 35° C in a water-miscible solution or water miscible dispersion with a water and noncombustible solids content of more than 80% by weight, and which does not sustain combustion; g) distilled spirits and wines in wooden barrels or casks. This Part of ABNT NBR 17505 shall not apply to items listed in 1.1.1 of ABNT NBR 17505-1:2013. © ABNT 2015 - Todos 08 direitos reservados ix Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 Introdugao A aplicagdo desta Norma nao dispensa o atendimento a Legislacaio Nacional aplicével x © ABNT 2018 - Todos 08 direitos reservados Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” NORMA BRASILEIRA ABNT NBR 17505-4:2015 Armazenamento de liquidos inflamaveis e combustiveis Parte 4: Armazenamento em recipientes e em tanques portateis até 3 000 L 1 Escopo 1.1. Esta Parte da ABNT NBR 17505 prescreve os requisitos para o armazenamento de liquidos inflamaveis e combustiveis nas seguintes condicées: a) tambores ou outros recipientes que néo excedam 450 L em suas capacidades individuais; b) _tanques portateis que nao excedam 3 000 L em sua capacidade individual; ©) _recipientes intermedirios para gtanel que nao excedam 3 000 L em suas capacidades individuais. 1.2 Esta Parte da ABNT NBR 17505 também se aplica as transferéncias eventuais entre recipientes. 1.3 Esta Parte da ABNT NBR 17505 também se aplica aos recipientes de resgate quando utilizados para armazenamento tempordrio de embalagens, de produtos ou de residuos provenientes de acidentes ou incidentes que nao excedam 230 L de capacidade. Tais embalagens de resgate devem ser tratadas como recipientes, como definido na ABNT NBR 17505-1:2013, 3.91 a 3.94. 1.4 Paratanques portateis cuja capacidade individual exceda 3.000 L, devem-se aplicarasprescrigdes da ABNT NBR 17505-2. 1.5 Esta Parte da ABNT NBR 17505 nao se aplica a: a) _recipientes, recipientes intermediérios para granel (/BO) ¢ tanques portateis que estejam sendo utiizados em areas de proceso, conforme descrito na ABNT NBR 17505-5; = liquido sem tanques de combustivel de veiculos a motor, aeronaves, barcos, motores portateis ou estacionarios; bebidas, quando embaladas em recipientes individuais, cuja capacidade individual no ultrapasse 5L; 2 remédios, alimentos, cosméticos e outros produtos de consumo que contenham no maximo 50 % ‘em volume de liquidos misciveis em Agua, desde que a solugao resultante nao seja inflamavel ‘ou combustivel, quando embalados em recipientes individuais que nao excedam 5 | de capacidade; €) _liquidos que nao tenham ponto de igni¢ao, quando ensaiados pela ABNT NBR 11341, ou norma ‘equivalente para produtos quimicos, até seu ponto de ebulicao ou até uma temperatura em que a amostra usada no ensaio apresente uma mudanca evidente de estado fisico; f) liquidos com um ponto de fulgor superior a 35 °C em uma solugao ou disperséo miscivel ‘em Agua, com um contetido de sélidos inertes (nao combustiveis) e de agua de mais de 80 % ‘em peso, que nao mantenham combustéo; g) bebidas destiladas e vinhos em bartis ou pipas, de madeira. 1.6 Para as restrigGes ao emprego desta Parte da ABNT NBR 17505, ver ABNT NBR 17505-1:2013, 1.2. ‘© ABNT 2015 - Todos os aires reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 1.7 As disposicées desta Parte da ABNT NBR 17505 nao se aplicam as edificacdes, equipamentos, estruturas ou instalagGes ja existentes ou aprovadas para a construgao ou instalacao antes da data da publicagao da ABNT NBR 17505 (todas as Partes). Contudo, as reformas que alterem as carac- teristicas do projeto e/ou equipamentos, e as ampliagdes de instalacées, iniciadas a partir da data da publicago desta Parte ABNT NBR 17505 devem atender as suas disposigdes. Nestes casos, devem ser evidenciadas as Normas vigentes, na época do fato, para as edificagdes, equipamentos, estruturas ou instalagées jé existentes ou aprovadas. 2 Referéncias normativas Os documentos relacionados a seguir so indispensaveis a aplicacao deste documento. Para referéncias datadas, aplicam-se somente as edicdes citadas. Para referéncias nao datadas, aplicam-se as edigdes mais recentes do referido documento (incluindo emendas). ABNT NBR 9077, Saidas de emergéncias em edificios ABNT NBR 10897, Prote¢do contra incéndio por chuveiros automaticos ~ Requisitos ABNT NBR 11742, Porta corta-fogo para saida de emergéncia - Especificacao ABNT NBR 12693, Sistemas de prote¢ao por extintores de incéndio ABNT NBR 13792, Protegao contra incéndio, por sistema de chuveiros autométicos, para areas de armazenamento em geral — Procedimento ABNT NBR 17505-1, Armazenamento de liquidos inflaméveis e combustiveis — Parte 1: Disposigdes Gerais ABNT NBR 17505-2, Armazenamento de liquidos inflamaveis e combustiveis— Parte 2: Armazenamento em tanques e em vasos ABNT NBR 17505-5, Armazenamento de liquidos inflamaveis e combustiveis - Parte 5: Operagées ABNT NBR 17505-6, Armazenamento de liquidos inflamaveis e combustiveis ~ Parte 6: Instalagdes @ equipamentos elétricos ASTM F 852, Standard specification for portable gasoline containers for consume use ASTM F 976, Standard specification for potable kerosine and diesel containers for consume use NFPA 10, Standard for portable fire extinguishers NFPA 13, Standard for the installation of sprinkler systems NFPA 14, Standard for the installation of standpipe and hose systems NFPA 16, Standard for the installation of foam-water sprinkler and foam-water spray systems NFPA 25, Standard for the inspection, testing and maintenance of water basefire protection systems NFPA 30 B, Code for the manufacture and storage of aerosol products 2 © ABNT 2018 - Todos 08 direitos reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 NFPA 69, Standard on explosion prevention systems NFPA 80, Standard for fire doors and fire windows NFPA 221, Standard for high challenge fire walls, fire walls, and fire barrier walls NFPA 251, Standard method of tests of fire resistance of building construction and materials NFPA 704, Standard system for identification of the hazards of materials for emergency response UL 30, Standard for metal safety cans UL 1318, Standard for non-metallic safety cans for petroleum products UL 1314, Standard for special purpose metal containers UL 2388, Fire exposure testing of intermediate bulk containers for flammable and combustible liquids 3. Termos e definig6es Para os efeitos desta Parte da ABNT NBR 17505, aplicam-se os seguintes termos ¢ definicdes. 34 recipiente intermediario para granel (IBC) conforme definido na ABNT NBR 17505-1:2013, 3.93 3.2 armazenamento protegido armazenamento de liquidos inflamaveis e combustiveis protegido de acordo com a Segao 24 3.3 (*) recipiente tipo com alivio de presséo recipiente metélico, recipiente intermediario para granel metalico ou tanque portatil metalic, equipados com no minimo um mecanismo de alivio de pressao no seu topo, projetado, dimensionado e montado para aliviar a pressao interna gerada em decorréncia de exposigo ao fogo, evitando uma ruptura violenta do recipiente 34 (*) resina poliéster insaturada uma resina que contenha até 50 % em peso de liquidos de classe | C, classe I! ou classe Ill, mas nado liquidos de classe | A ou! B 35 liquido viscoso liquido que se torne gelatinoso, espesso ou se solidifique quando aquecido, ou cuja viscosidade temperatura ambiente versus percentual contido de liquidos de classe |, classe II ou classe Ill encontre-se na porgdo sombreada da Figura A.1 NOTA Os liquidos descritos pela definigao acima incluem resinas espessas, adesivos e tintas. Alguns destes liquidos sao misturas que contem uma pequena porcentagem de Iiquidos volateis inflamaveis ou combustiveis, resultando em uma mistura nao combustivel ‘© ABNT 2015 - Todos os aires reservados 3 Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 3.6 liquido miscivel em agua liquido que se mistura em todas as proporgdes com a agua, sem o auxilio de aditivos quimicos, como agentes emulsificantes 4 Requisitos gerais 4.1. Os requisitos gerais desta Parte da ABNT NBR 17505 sdo aplicaveis ao armazenamento de liquidos, como especificado nas Segdes 18 a 21, independentemente das quantidades armazenadas. Excegdo: Onde houver requisitos mais restritos nas Secdes 18 22, estas restricdes devem prevalecer. 4.2 Para os propésitos das Segdes 18 a 24, os liquidos instaveis devem ser tratados como liquidos de classe | A. 4.3 Requisitos de evacuagao de area devern estar de acordo com a ABNT NBR 9077. O armazenamento de liquidos nao pode obstruir fisicamente as vias de evacuagao. 4.4 Para os efeitos das Segdes 4, 18, 20 e 24, armazenamento protegido significa que este esté protegido de acordo com a Seco 24. Todos os outros armazenamentos devem ser considerados sem protecdo, a nao ser que tenham sido adotados meios alternativos de protecao aprovados pela Corporagaio de Bombeiros local (ver 24.1.5 @ 24.7). 4.5 Pode ser utiizada madeira, com uma espessura nominal minima de 25 mm, na construgéo de prateleiras, suportes, paletes, plataformas, sobrepisos ¢ instalagGes similares. 4.6 _Liquidos de classe | ndo podem ser armazenados em pordes ou nos subsolos. 4.7 _Liquidos das classes Ile Ill A podem ser armazenados em pordes ou subsolos, desde que protegidos de acordo com a Segao 24. 4.8 Liquidos de classe III B podem ser armazenados em pordes ou subsolos. 4.9 Onde forem empilhados recipientes, recipientes intermediarios para granel ou tanques portateis, eles devem ser empilhados de forma a manter a estabilidade da pilha e a evitar esforcos excessivos nas paredes dos recipientes. 4.9.1 Tanques portéteis e recipientes intermedidrios para granel podem ser armazenados em mais de um nivel, desde que projetados seguramente sem o uso de chapas intermedirias. 4.9.2 Equipamentos de movimentacaio de carga devem ser capazes de alcancar e movimentar 6s recipientes, tanques portateis ¢ recipientes intermedidrios para granel que estejam armazenados em todos os niveis de armazenamento. 4.10 Recipientes, recipientes intermedidrios para granel e tanques portateis, que estejam em areas desprotegidas de armazenamento de liquidos, nao podem ser armazenados em uma distancia inferior a1 mde traves, vigas ou outras pecas da estrutura de cobertura. 4.11. Liquidos utiizados para manutengao de edificac&o, pintura ou outras manutengées similares © nao frequentes podem ser armazenados em recipientes fechados fora de armarios e no interior de dreas de armazenamentos de liquidos, se nao excederem uma quantidade para 10 dias de suprimento na taxa de consumo estimado. 4 © ABNT 2018 - Todos 08 direitos reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 5 Recipientes aceitaveis 5.1 (*) Somente os seguintes recipientes, recipientes intermediarios para granel e tanques portéteis 0 aceitaveis no armazenamento de liquidos de classe |, classe Il e classe Ill A a) recipientes, recipientes intermediarios para granel e tanques portateis, quando metalicos, se estiverem de acordo com os requisitos e se contiverem produtos em embalagens homologadas conforme “Regulamentaco do Transporte de Produtos Perigosos” do Ministério dos Transportes/ Agéncia Nacional de Transportes Terrestres; b) recipients metalicos ou em plistico que atendam aos requisitos @ ao uso com produtos de petréleo de acordo com 0 escopo de uma ou mais das ASTM F 852, ASTM F 976, UL 1313, UL 30, UL 1314; ©) recipientes plésticos que atendam aos requisitos ¢ que contenham produtos autorizados por Legislacao especifica, oriunda da Agéncia Nacional de Transportes Terrestres (ANTT). Sao também aceitéveis as embalagens conforme regulamentagdes emanadas da Agéncia Nacional de Transporte Aquavigrio (ANTAQ) e Agéncia Nacional de Aviagao Civil (ANAC); NOTA — Recipientes de pldstico de construcdo com parede muito fina, semelhante aqueles utilizados na maioria dos produtos de consumo @ que nao séo previstos para 0 reenvase, néo podem ser reutilizados como armazenamento de liquidos inflamaveis @ combustiveis. Embora esses recipentes sejam permitidos para embarques Unicos de algumas classes de Ifquidos inflamaveis e combustiveis, eles nao atendem a0s requisitos rigidos estabelecidos nas normas referenciadas em 5.1 b). d)_tambores de fibra que atendam aos requisitos e que contenham produtos autorizados por legislagao especifica oriundada Agéncia Nacional de Transportes Terrestres (ANTT). Sao também aceitaveis as embalagens conforme regulamentacdes emanadas da Agéncia Nacional de Transporte Aquaviario (ANTAQ) e Agéncia Nacional de Aviacao Civil (ANAC); ©) _(*) recipientes intermedidrios para granéis (IBC) em materiais nao metalicos rigidos que atendam 0s requisitos e contenham produtos autorizados pela Agéncia Nacional de Transportes Terrestres (ANTT). Sao também aceitaveis as embalagens conforme regulamentagdes emanadas da Agéncia Nacional de Transporte Aquaviario (ANTAQ) e Agéncia Nacional de Aviacao Civil (ANAC); — otermo recipiente intermedirio para granel rigido e ndo metalico refere-se a um equipamento composto de vaso pldstico de contengao priméria ao liquido que deve ser fechado ou encapsulado por uma estrutura externa metdlica, uma parede de conten¢ao simples de metal ou pldstico, uma parede dupla de pléstico sélido ou expandido ou uma estrutura de cartao de fibra vegetal. O termo recipiente intermedidrio para granel rigido e nao metalico também denota um /BC de parede unica de plastico que pode ou nao possuir uma base separada de plistico, que também serve como estrutura de suporte para o vaso plastico. Os IBC’s que tenham uma estrutura externa de metal estanque sao considerados IBC’s metalicos ou tanques portateis metalicos como definidos em 5.1 f) _recipientes de vidro com a capacidade limite definida na Tabela A.1 de acordo com o Regulamento pata 0 Transporte Rodovidrio de Produtos Perigosos do Ministério dos Transportes (ANTT). Sao também aceitaveis as embalagens conforme regulamentagdes emanadas da Agéncia Nacional de Transporte Aquaviario (ANTAQ) e Agéncia Nacional de Aviagao Civil (ANAC). 5.1.1 Para armazenamento protegido, recipientes intermediarios para granel rigidos e nao metalicos, ‘como descrito em 5.1 e), devem ser submetidos a um ensaio de fogo que demonstre seu desempenho aceitével para esta condigao de armazenamento interno ¢ devem ser adequadamente identificados com a marcagao da homologacao do ensaio. ‘© ABNT 2015 - Todos os aires reservados 5 Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 5.1.2 Medicamentos, bebidas, alimentos, cosméticos e outros produtos comuns de consumo, quando embalados de acordo com as praticas aceitaveis para vendas a varejo, devem ser isentos dos requi- sitos de 5.1 ¢ da Tabela A.1. 5.2 Cada tanque portatil ou recipiente intermedirio para granel deve ser provido por um ou mais dispositivos instalados no topo, com capacidade de alivio de emergéncia suficiente para limitar a pressao interna, sob condigdes de exposi¢ao ao fogo, a uma pressao manométrica de 70 kPa ou a 30 % da pressao de ruptura do tanque portatil, adotando-se o maior valor 5.2.1 Acapacidade total de alivio néo pode ser inferior & especificada na ABNT NBR 17505-2:2013, 5.5.3.2 00 5.5.3.4. 5.2.2 Deve ser utiizado no minimo um dispositive de alivio de pressio, com capacidade minima de 170 m3 de ar livre por hora (760 mmHg a 15,6 °C). O alivio deve ser ajustado para abrir a uma pressao superior a 35 kPa. 5.2.3 Se forem utiizados allvios do tipo fusivel (plugues-fusiveis) estes devem ser ativados por elementos que atuem a uma temperatura abaixo de 150 °C. Quando houver possibilidade de travamento de um alivio ativado por pressao, como os utilizados em embalagens para tintas, dleos de secagem ou materiais similares, os plugues fusiveis ou dispositivos de ventilacao que se fundam a uma temperatura maxima de 150 °C, sob exposigao ao fogo, podem ser utilizados como dispositivos de alivio de emergéncia. 5.3 A capacidade maxima permitida para um recipiente, recipiente intermediario para granel ou tanque portatil metélico para liquidos de classe |, classe I e classe Ill A, nao pode exceder as especificagdes contidas na Tabela A.1 Excegao: Conforme previsto na Sedo 1 e em 5.3.1,5.3.265.3.3. 5.3.1 Liquidos misciveis em Agua de classe | B e classe | C podem ser armazenados em recipientes de pldstico de até 230 L de capacidade, se armazenados ¢ protegidos de acordo com 24,3.2.7. 5.3.2 Os liquidos de classe | A e de classe | B podem ser estocados em recipientes de vidro com capacidade individual maxima de § L, se a pureza requerida pelo liquido puder ser afetada pelo armazenamento em recipientes metdlicos ou se o liquido puder causar corroséo excessiva em recipientes metalicos. 5.3.3. Recipientes com vazamento ou danificados, com capacidade individual maxima de 230 L, podem ser liberados para serem armazenados, temporariamente, de acordo com 5.1, 5.2 € 5.3.6 com as Secdes 18, 19 € 20, desde que sejam encapsulados em recipientes de sobre-embalagem 5.3.3.1 Para ser considerado um armazenamento protegido como definida em 4.4 e de acordo com aSecao 24, um recipiente de sobre embalagem deve ser fabricado com material compativel com © produto que esteja armazenado no recipiente original (com vazamento ou danificado). 5.3.3.2 Recipientes de sobre-embalagem metalicos devem ser considerados recipientes do tipo sem alivio de pressao. 6 (*) Armarios (gabinetes) para armazenamento de liquidos inflamaveis 6.1 O volume de liquidos de classe |, classe II e classe II A armazenado em um armario de arma- Zenamento individual nao pode exceder 460 L. 6 © ABNT 2018 - Todos 08 direitos reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 6.2 Ovolume total agregado de liquidos de classe |, classe Il e classe Ill A estocado em um grupo de armérios de armazenamento nao pode exceder a quantidade maxima permitida de liquidos inflamaveis e combustiveis por drea de controle, baseado no tipo do local de ocupagao onde os arma- rios estiverem locados. 6.3 Devem ser aceitos para armazenamento de liquidos os armarios que atendam no minimo a.um dos seguintes requisitos: a) b) a) 64 quando forem projetados e construidos para limitar a temperatura interna, no centro do armario a 2,5 om do seu topo ano maximo 160 °C, quando submetidos a 10 min de exposigao ao fogo com ensaio de acordo com a Norma Brasileira aplicavel ou, na inexisténcia desta, de acordo com a NFPA 251, para condi¢ao de fogo. Todas as juntas e soldas devem permanecer estanques © as portas devem permanecer fechadas durante todo o ensaio; metélicos, se construidos da seguinte maneira: 1) 0 fundo, o topo, a porta e as laterais do armario devem ser de chapas de ago de bitola n? 18, no minimo, ¢ de parede dupla com espagamento minimo de 38 mm; 2) as jungdes devem ser rebitadas, soldadas ou tornadas herméticas por um meio igualmente eficiente; 3) @ porta deve ser equipada com uma dobradiga de trés pontos e a soleira da porta deve ficar no minimo 5 cm acima do fundo, para reter o liquido eventualmente derramado dentro do armario; de madeira, se construidos da seguinte maneira: 1) 0 fundo, as laterais e 0 topo devem ser feitos em madeira compensada de qualidade, do tipo para exteriores, com espessura minima de 2,5 cm, resistente ao rompimento e separacao das léminas, em condigdes de ine&ndio: 2) todas as jungdes devem ser entalhadas ¢ fixadas em duas diregdes, com parafusos para madeira; 3) quando forem utilizadas mais de uma porta, elas devem ter uma borda entalhada sobreposta de mais de 2,5 cm; 4) as portas devem ser equipadas com fechos e dobradigas e devem ser montadas de maneira que seja garantida a sua capacidade de resisténcia, quando sujeitas a exposigao ao fogo; 5) deve ser previsto no fundo do armario um batente mais alto ou uma contengo com capacidade para 5 cm de liquido eventualmente derramado no armario: so aceitaveis armarios certificados que tenham sido construidos e ensaiados de acordo com 6.3. a) (*) Os armérios de armazenamento nao necessitam de ventilacao com o propésito de protecao contra incéndio. 6.4.1 Se os armérios no dispuserem de ventilagao, as aberturas dos respiros devem ser vedadas com os tampées fornecidos juntamente com os armarios ou com tampées especificados pelo fabricante. ‘© ABNT 2015 - Todos os aires reservados 7 Arquivo de mpressao gerado em 19/10/2017 16:01:40 de Uso exdlusWo de ABB LTDA-OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 6.4.2 (*) Se por alguma razao 0 armario de armazenamento dispuser de ventilacao, a saida da ventilagdo deve ser conduzida diretamente para o exterior ou para um dispositive de tratamento projetado para controlar compostos organicos volateis e vapores inflamaveis, de tal forma que nao seja comprometida o desempenho especificado para o armario e de forma que seja aceitavel pela Corporagao de Bombeiros local, 6.5 (") Os armarios de armazenamento devem ser identificados como a seguir: ATENGAO INFLAMAVEL MANTER LONGE DO FOGO 6.5.1 Aaltura minima das letras para a palavra INFLAMAVEL (alerta) deve ser de 50 mm e a altura minima das letras para a frase MANTER LONGE DO FOGO (mensagem) deve ser de 25 mm. 6.5.2 Todas as letras devem ser maitisculas e em cor contrastante com o fundo, 6.5.3 A marcacdo deve ser aposta na parte superior da(s) porta(s) ou do corpo dos armarios de armazenamento. 6.5.4 Podem ser aceitos simbolos internacionais, como “inflamavel” (uma chama em um tridngulo), “manter afastado do fogo” (uma chama cortada em um circulo”) 7 Quantidades maximas permitidas por area controlavel de armazenamento 7.1 Limites em estabelecimentos em geral ‘As quantidades maximas permitidas de liquidos em cada area controlavel de armazenamento em establecimentos em geral, nao industriais e em distribuidores, nao podem exceder as quantidades especificadas na Tabela A.2. Excegao: Como alteradas em 7.2 ¢ pelas Segées 18, 19, 20, 216 22. 7.2 Limites em estabelecimentos especiais 7.21 Para os seguintes estabelecimentos as quantidades maximas permitidas por érea controlavel de armazenamento nao podem exceder as quantidades especificadas na Tabela A.3: a) assembiéias; b) ambulatérios de pronto-socorro; ©) escritérios; d)cteches; €) _presidios ¢ casas de corregao; f) educandarios; 8 © ABNT 2018 - Todos 08 direitos reservados Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 9) assisténcias médicas; h) residéncias. 7.2.2 Para as ocupagées especificadas em 7.2.1, 0 armazenamento de quantidades superiores 4.40 L de liquidos de classe | e de classe Il combinados ou superiores a 250 L de liquidos de classe Ill As6 deve ser permitido se armazenados em armarios de armazenamento de liquidos e se a quanti- dade total agregada no exceder a 700 L. 7.2.3 E permitido exceder as quantidades especificadas na Tabela A.2 para os combustiveis contidos nos tanques de equipamentos méveis, desde que sejam operados de acordo com a legislacéo de seguranca contra incéndio. 7.24 Para estabelecimentos clasificados como ambulatérios de pronto socorro, creches, assisténcias médicas e educandérios, as quantidades maximas permitidas para liquidos de classe Ill B podem ser aumentadas em 100 %, se a edificagao for protegida por um sistema de chuveiros automa ticos instalado de acordo com a Norma Brasileira aplicavel ou, na inexisténcia desta, com a NFPA 13 8 Area controlavel de armazenamento 8.1 Para os objetivos desta parte da Norma, uma tea controlavel de armazenamento 6 0 espago dentro de uma edificagdo de uso geral, exceto armazéns para liquidos, areas de processo @ areas comerciais, onde quantidades de liquidos armazenados nao excedam as quantidades maximas permitidas pelas Tabelas A.2 ¢ A.3. 8.2 Areas controlaveis de armazenamento devem ser separadas umas das outras por barreiras corta-fogo, de acordo com a Tabela A.4. 8.3 Areas controlaveis de armazenamento situadas abaixo do solo, que possam ser consideradas pordes, nao podem ser utilizadas para o armazenamento de liquidos de classe |. 9 Requisitos para construgao 9.1 Todas as areas de armazenamento devem ser construidas de forma a atender as classifica- Ges de resisténcia ao fogo especificadas pela Corporagdo de Bombeiros local e na Tabela A.5 As construgdes devem ser executadas de acordo com as especificacdes de ensaios estabelecidas na Norma Brasileira aplicavelou, na inexisténcia desta, na NFPA 251 9.2 As aberturas em paredes de salas internas, externas ou de edificagdes adjacentes com tempo de resisténcia ao fogo definido, devem ser providas com portas corta-fogo, que devem permanecer normalmente fechadas, e atender ao tempo de resisténcia de acordo com a Tabela A.6. 9.2.1 Estas portas podem ser instaladas pata permanecerem abertas durante as operagdes de manuseio do material, somente se forem projetadas para fechar automaticamente no caso de uma emergéncia de incéndio, com dispositivos de fechamento aprovados pela Corporagéio de Bombeiros local. 9.2.2 As portas corta-fogo devem ser instaladas de acordo com a ABNT NBR 11742 ou a NFPA 80. 9.3 O projeto de construgio das paredes externas deve prever um acesso rapido para operagdes de combate a ineéndio, através de aberturas de acesso, janelas ou painéis de parede nao combustiveis, © construidos com materiais leves. Excegdo: Este requisito nao se aplica a salas internas, ‘© ABNT 2015 - Todos os aires reservados 9 Arguive de mpressao gerado em 19/1 0/2017 16:01:40 de uso excluswo de ABE LTDA- OSASCO Arquivo de Impressao gerade em 19/10/2017 15.01.40 de uso exchisivo de ABB LTDA - OSASCO” ABNT NBR 17505-4:2015 10 Protecao contra incéndio 10.1 Armazenamento protegido Os requisitos de protegao contra incéndio para um armazenamento protegido devem atender a08 requisitos de 10.2 e da Seco 24. 10.2 Protecao manual contra incéndio 10.2.1 Extintores de incéndio portateis devem atender aos requisitos da ABNT NBR 12693, da NFPA 10 ou desta Parte da ABNT NBR 17505. 10.2.2 Os extintores de incéndio portateis devem atender 4 ABNT NBR 12693 e aos seguintes requisitos: a) no minimo um extintor de ineéndio portatil, com uma capacidade extintora minima de 40:B, deve estar localizado externamente a porta de entrada, a uma distancia inferior a 3,0 m de uma area interna de estocagem de liquidos; b) no minimo um extintor de incéndio portal, com capacidade extintora minima de 40:B, deve estar localizado a menos de 9,0 m de distancia de qualquer area de armazenamento de liquidos de classe | ou classe Il, localizado fora de uma rea interna de armazenamento de um depésito de liquidos. Excegao: Uma alternativa aceitavel é dispor de pelo menos um extintor de incéndio portétil, com capacidade extintora de 80:B, localizado a uma distancia inferior a 15,0 m da area de armazenamento em questao. 10.2.3 Onde estiverem previstas, conexdes de mangueira ligadas ao sistema de chuveiros autométicos devem ser instaladas de acordo com a Norma Brasileira aplicavel ou, na inexisténcia desta, com a NFPA 13. 10.2.4 Onde estiverem previstas, conexdes de mangueiras ligadas ao sistema de reservatorio elevado devem ser instaladas de acordo com a Norma Brasileira aplicavel ou, na inexisténcia desta, com a NFPA 14 10.2.5 Onde previstas, conexdes de mangueira deve também atender aos seguintes requisitos: a) devem ser previstas conexGes de mangueiras para protecao de armazéns gerais e para protecao de armazéns para liquidos; b) onde forem providas mangueiras pré-conectadas, estas devem ser de 3,81 cm, com forro interno ou mangotinhos de 2,54 cm de borracha rigida, utiizando-se uma combinagao adequada de bocais de jato pleno e de neblina. 10.2.6 Onde forem previstas conexées de mangueira, o suprimento de agua deve ser suficiente para atender 4 demanda do sistema fixo de combate a incéndio mais uma vazao que totalize, no minimo, 1 900 L/min para os sistemas externo e interno de conexdes de mangueiras, por um periodo minimo de 2 h, a nao ser que seja estabelecido em contrario na Segao 24. 11 Sistemas elétricos 11.1 Classificagao de areas elétricas nao podem ser requeridas para areas de armazenamento de liquidos se todos os recipientes, recipientes intermediatios para granel ¢ tanques portateis forem selados e no forem abertos no local, exceto como previsto em 11.2. 10 © ABNT 2018 - Todos 08 direitos reservados

You might also like