Technical Data Sheet for Low Voltage Cables

Construction
Reference Standard IEC 60502-1, IEC 60228, IEC 60332-1, IEC 60332-3-22 Cat A
Short Description CU/XLPE/SWA/PVC
Voltage Grade 0.6/1kV
Conductor Type Stranded Plain Copper Conductor according to IEC 60228 Class 2
Insulation XLPE
Bedding PVC / Black
Armouring Galvanized Steel Wires
Sheathing PVC / Black

Cable Marking (Embossed) =EL SEWEDY CABLES= No. of Cores x Size CU/XLPE/SWA/PVC 0.6/1kV IEC 60502-1 Manufacturing Year

Note: Polypropylene and/or Polyester binder tape(s) and/or fillers may be used over cores or armour when necessary according to manufacturing process

Core Identification
2 Cores Red, Black 4 Cores (4G) Red, Yellow, Blue, Y/G
3 Cores (3G) Red, Black, Y/G 5 Cores (5G) Red, Yellow, Blue, Black, Y/G

Packing
Cable will be supplied in lengths as indicated in drum schedule considering ± 5% length tolerance on non returnable wooden drums.
Both ends of the cable will be sealed to prevent the ingress of moisture during transportation and storage.
Each reel will be marked with type, size and length of cable, and gross weight written on metallic tage nailed properly on the flange.
Metering on cable outer sheath will be started from "X" to "X+999" m for 1000m cutting lengths and to "X+499" m for 500m cutting lengths.

Cable Features
Conductor Max. Operating Temperature 90 °C
Conductor Max. Temp. During Short Circuit 250 °C
Cable outer sheath will be anti-termite resistant & flame retardant according IEC 60332-3-22 Cat A

Tests
Conductor electrical resistance will be according IEC 60228. All thicknesses will be measured according to design standard
Routine tests will be generally to IEC 60502-1 Test certificate will be supplied on request

Laying Conditions
Cable must be protected from direct solar radiation and other thermal sources in the neighborhood. Cables current capacity are based on below laying conditions
Cable formation Trefoil Air temperature (°C) 40 Frequancy (Hz) 50
Soil thermal resistivity (˚C.m/W) 1.2 Ground temperature (°C) 35 Burial depth (m) 0.5

Specifications and Electrical Parameters


Max.
Apporx. Apporx. Max. conductor Conductor Current Current Current
Min bending conductor DC
No. of Size outer Cable AC resistance at short circuit current Laid in Laid in Laid In
ID CODE raduis resistance at
diam. weight 90°C at 1 Sec Ground Duct Free Air
20°C
Cores mm2 mm kg/km mm Ω/Km Ω/Km kA A A A
I64412922 2 4 14.5 413 116 4.61 5.88 0.57 51 41 47
I64412924 2 6 15.7 499 126 3.08 3.93 0.85 64 53 61
I64412912 2 10 17.5 701 140 1.83 2.34 1.43 83 70 80
I64412915 2 16 19.5 896 156 1.15 1.47 2.28 107 84 106
I64412937 3 2.5 14 389 112 7.41 9.45 0.35 33 27 30
I64412949 3 4 15.1 465 121 4.61 5.88 0.57 46 37 42
I64412954 3 6 16.4 570 132 3.08 3.93 0.85 58 46 51
I64412928 3 10 18.4 812 148 1.83 2.34 1.43 76 61 69
I64412934 3 16 20.5 1068 164 1.15 1.47 2.28 98 76 90
I64413096 4 2.5 14.9 436 120 7.41 9.45 0.35 33 27 30
I64413107 4 4 16.1 537 129 4.61 5.88 0.57 46 37 42
I64413110 4 6 18.3 770 147 3.08 3.93 0.85 58 46 51
I64413087 4 10 19.7 955 158 1.83 2.34 1.43 76 61 69
I64413093 4 16 22.8 1387 183 1.15 1.47 2.28 98 76 90