Greenhouses p. 3
Features p. 6
Air extraction p. 8
Air circulation p. 12
Fan insulation p. 15
Air heating p. 17
Air inlet p. 19
Cooling p. 21
AIR EXTRACTION
COOLING
AIR CIRCULATION
Natural Ventilation
Tunnel Ventilation
FAN INSULATION
AIR HEATING
MUNTERS PROTECT
In agriculture, corrosion is usually caused by a combination of many factors such as pH, high humidity levels,
frequent contact with water, aggressive chemicals as found in manure or disinfectants, bacterial growth; and
the list goes on. The industry is also continuously evolving and that might have surprising side effects: new
agricultural chemicals or feed additives might do wonders for animal or plant health, but also enhance corrosion
on metal products. For offering a consistent remedy to corrosion troubles Munters switched to a new material,
called Munters Protect, which offers extremely high protection against corrosion. It consists of a coating made
of Zinc, Aluminum and Magnesium and it delivers the best corrosion resistance performance, up to 10 times
better than galvanised steel.
MOTORS
Munters is able to offer a wide range of motor power, depending on the application and the fan size. The
smallest fan Munters produces, the 18” air recirculator EDC18 is equipped by a 0.33 Hp motor. The minimum
ventilation fans and air recirculators can be equipped by a 0.5 or 0.75 Hp motor. The exhaust fan used for
tunnel ventilation can be equipped by 1.0 or 1.5 Hp motor. For the recent production of big diameter fans, like
EM52 and EC52, Munters has fitted them with a powerful 2.0 Hp motor. Most of the models of fans allows
speed control obtained either by inverter (VFD) or autotransformer. This huge flexibility in the offering has been
developed for being able to cover any demand in terms of airflow which might rise from our customers.
MUNTERS DRIVE
Ventilation inefficiencies are mainly related to 3 major causes: the types of motors used as the design of AC
motor has physical limitations; the belt drive systems as the friction on the transmission components energy
causes an energy loss and a high level of maintenance; the fixed single revolution speed and consequent fixed
capacity, which prevents energy savings when ventilation demand is low. Munters Drive avoids these limitations
through 3 innovations: a new motor architecture which shows a more efficient performance; the direct drive
which makes the motor turning at the same revolution speed as the optimum propeller speed, eliminating friction
losses and the need of maintenance; and the variable speed which reduces the motor speed and fan capacity
when ventilation demand is low, generating significant energy savings. By combining the energy efficiency
benefits that a Munters Drive offers over a conventional fan, users have been able to reduce annual ventilation
costs by up to 40% and additionally saved a similar amount in maintenance cost reduction.
LOADING VOLUMES
Munters has developed an optimized loading displacement for combined loads on 20ft, 40ft and 40ft high
cube containers and standard trailers*, which allows to balance volume and weight for delivery of complete
system of fans, pad, accessories and heaters. Fans can be delivered assembled, in partially assembled form
and fully disassembled depending on the number of products involved. The cooling pad and other accessories
can be stored as well inside the container/trailer in order to completely fill the empty space fore and optimize
the transport costs. Therefore, all the loading volumes shown in the catalogue are just a few of the many loading
options available. Assembly manuals are provided for easy mounting of the received products.
* 13.60x2.40x2.60m
PERFORMANCES
Motor 1.0Hp 2.0Hp
Airflow at 0 Pa m /h [cfm]
3
42,200 [24,900] 49,500 [29,100]
Airflow at 25 Pa m3/h [cfm] 35,100 [20,700] 44,700 [26,300]
Airflow at 50 Pa m /h [cfm]
3
26,200 [15,400] 36,400 [21,400]
Specific performance at 0 Pa m3/h/W [cfm/W] 43.7 [25.7] 32.7 [19.2]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Container 20 ft pcs. 14 100
Container 40 ft pcs. 30 220
Container 40 ft HC pcs. 30 220
Trailer 13.60x2.40x2.60 m pcs. 36 250
EUROEMME® EM50
•• Family member of the time proven Euroemme® fan range
•• Propeller is statically and dynamically balanced
•• Patented centrifugal system permits an energy efficient solution
•• Powerful springs keep shutters firmly closed when fan is not operating
•• Every fan is individually checked for quality
•• Fan housing and Venturi made of strong Munters Protect coated sheet-steel
•• Shutters are made of pressed Munters Protect coated steel in order to ensure
highest strength
•• Central hub and v-belt pulley are made from die-cast aluminium, with reinforced
ribs for prolonged lifetime
PERFORMANCES
Motor 1.0/1.2Hp 1.5Hp
Airflow at 0 Pa m3/h [cfm] 37,000 [21,800] 42,400 [25,000]
Airflow at 25 Pa m3/h [cfm] 32,500 [19,200] 38,400 [22,600]
Airflow at 50 Pa m3/h [cfm] 26,200 [15,400] 33,800 [19,900]
Specific performance at 0 Pa m /h/W [cfm/W]
3
33.9 [20.0] 27.0 [15.9]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Container 20 ft pcs. 29 170
Container 40 ft pcs. 58 250
Container 40 ft HC pcs. 58 250
Trailer 13.60x2.40x2.60 m pcs. 65 300
PERFORMANCES
Motor 0.5Hp 0.75Hp 1.0Hp
Airflow at 0 Pa m /h [cfm]
3
18,800 [11,070] 20,500 [12,080] 23,400 [13,760]
Airflow at 25 Pa m3/h [cfm] 16,000 [9,420] 18,100 [10,630] 21,400 [12,610]
Specific performance at 0 Pa m /h/W [cfm/W]
3
32.6 [19.2] 27.2 [16.0] 22.6 [13.3]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Container 20 ft pcs. 54 170
Container 40 ft pcs. 108 300
Container 40 ft HC pcs. 108 300
Trailer 13.60x2.40x2.60 m pcs. 120 360
EUROEMME® EM30
PERFORMANCES
Motor 0.5Hp 0.75Hp
Airflow at 0 Pa m3/h [cfm] 14,100 [8,300] 15,300 [9,020]
Airflow at 25 Pa m3/h [cfm] 12,100 [7,120] 13,600 [8,030]
Specific performance at 0 Pa m3/h/W [cfm/W] 24.4 [14.4] 22.1 [13.0]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Container 20 ft pcs. 72 200
Container 40 ft pcs. 144 400
Container 40 ft HC pcs. 144 400
Trailer 13.60x2.40x2.60 m pcs. 168 400
PERFORMANCES
Model ED24HE ED30HE ED36HE
Motor 0.5Hp 0.5Hp 0.75Hp
Airflow at 0 Pa m /h [cfm]
3
9,100 [5,360] 14,400 [8,460] 19,100 [11,300]
Airflow at 12 Pa m3/h [cfm] 8,800 [5,180] 13,700 [8,080] 18,200 [10,700]
Airflow at 25 Pa m3/h [cfm] 8,400 [4,960] 12,900 [7,620] 17,200 [10,100]
Specific performance at 0 Pa m3/h/W [cfm/W] 17.3 [10.2] 22.1 [13.0] 30.3 [17.8]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Model ED30HE ED36HE ED30HE ED36HE
Container 20 ft pcs. 72 54 180 160
Container 40 ft pcs. 144 108 400 320
Container 40 ft HC pcs. 144 108 400 320
Trailer 13.60x2.40x2.60 m pcs. 168 120 400 360
PERFORMANCES
Model EDC18HE EDC18HE EDC24HE
Motor 4 poles - 0.33Hp 6 poles - 0.15Hp 4 poles - 0.5Hp
Airflow at 0 Pa m3/h [cfm] 5,046 [2,970] 3,483 [2,050] 10,087 [5,937]
Specific performance at 0 Pa m3/h/W [cfm/W] 15.6 [9.2] 17.2 [10.1] 17.7 [10.4]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
PERFORMANCES
Model EDC18 EDC18 EDC24
Motor 4 poles - 0.33Hp 6 poles - 0.15Hp 6 poles - 0.5Hp
Airflow at 0 Pa m3/h [cfm] 3,950 [2,325] 2,600 [1,530] 7,400 [4,350]
Specific performance at 0 Pa m3/h/W [cfm/W] 9.2 [5.4] 16.1 [9.5] 11.2 [6.6]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
PERFORMANCES
Motor 0.5Hp 0.75Hp
Airflow at 0 Pa m /h [cfm]
3
13,570 [7,990] 14,680 [8,640]
Specific performance at 0 Pa m3/h/W [cfm/W] 20.2 [11.9] 17.8 [10.5]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
EUROEMME® EDT30HE
PERFORMANCES
Motor 0.5л.с.
Airflow at 0 Pa m3/h [cfm] 14,400 [8,460]
Specific performance at 0 Pa m3/h/W [cfm/W] 22.1 [13.0]
* All values refer to 3 phases 50Hz single speed motors.
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
DIMENSIONS
Model FI36 FI50
Length [mm] 1,092 1,382
Height [mm] 1,092 1,382
Width [mm] 25 25
PERFORMANCES
Model GPmp100 GPmp130 GPmp160
Maximum heating power kW [kcal/h] 102.4 [88,043] 129 [110,871] 157 [134,780]
Working heating power kW [kcal/h] 93 [79,943] 116.5 [100,120] 141 [121,030]
Gas consumption natural gas [m3/h] 9.53 12.39 15.25
Gas consumption propane gas* [kg/h] 7.15 9.29 11.43
Diesel oil consumption l/h [gal/h] 9.5 [2.5] 12.0 [3.16] 14.6 [3.85]
IP class** IP54 IP54 IP54
* Nominal consumption at 15°C and 1,013.25mbar.
** Electric box IP grade.
LOADING VOLUMES
Model GPmp100 GPmp130 GPmp160
Container 20 ft pcs. 12 12 10
Container 40 ft pcs. 24 24 11
Container 40 ft HC pcs. 24 24 22
Trailer 13.60x2.40x2.60 m pcs. 28 28 24
Note: Shipping volumes include chimney kit, air outlet and air suction kit.
GFn85
•• Dedicated for Munters Agriculture applications
•• Unique frame design for convenient handling, transportation and installation
•• Ergonomic design for comfortable maintenance and full accessibility
•• IP55 enclosure of critical components e.g. electrical control box, electric motor
•• Predisposed 5 poles plug socket for farm controller or room thermostat connection
•• Corrosion resistant as housing components are made in Munters Protect or stainless steel AISI 430 and
combustion chamber made in stainless steel AISI 430
•• Safe design with photoelectric flame monitoring and overheating thermostat (airflow switch not needed)
•• Suitable for a wide variety of fuels i.e diesel oil (not bio-diesel) and winter diesel
PERFORMANCES
Maximum heating power kW [kcal/h] 80.6 [69.303]
Working heating power kW [kcal/h] 69.3 [59,587]
Diesel oil consumption l/h [gal/h] 7.5 [1.98]
IP class** IP55
** Electric box IP grade.
LOADING VOLUMES
Container 20 ft pcs. 48
Container 40 ft pcs. 108
Container 40 ft HC pcs. 108
Trailer 13.60x2.40x2.60 m pcs. 120
PERFORMANCES
Model SMT24 SMT30 SMT36 SMT50
Airflow at 0 Pa m /h
3
0 0 0 0
Airflow at 20 Pa m3/h 6,754 11,642 14,331 27,090
Airflow at 40 Pa m3/h 9,396 16,210 20,110 38,261
Airflow at 60 Pa m3/h 11,463 19,656 244,91 46,346
Note: airflow data are measured at standard conditions (20°C, 1,013hPa)
LOADING VOLUMES
ASSEMBLED DISASSEMBLED
Model SMT30 SMT36 SMT50 SMT30 SMT36 SMT50
Container 20 ft pcs. 264 200 116 900 750 600
Container 40 ft pcs. 528 400 232 1,400 1,400 1,000
Container 40 ft HC pcs. 528 400 232 1,400 1,400 1,000
Trailer 13.60x2.40x2.60 m pcs. 616 480 277 1,800 1,650 1,150
STANDARD DIMENSIONS
Length mm 600
Height mm 1,000 1,500 1,800 2,000
Width mm 100/150
DISTRIBUTION PAD CELdek® 70120
Length mm 600
Height mm 30
Width mm 100/150
ACCESSORIES: LIGHT FILTERS FOR CELdek®
High light reduction factor.
CELdek® 7060-15
•• High evaporation efficiency and superb wetting properties
•• Low pressure drop when wet, leading to lower operating costs
•• No water carry-over
•• Low scaling and self cleaning
•• Strong and self supporting
•• Long life time and low running costs
•• Quick and easy to install
•• Environmentally friendly
•• Consistent high quality
STANDARD DIMENSIONS
Length mm 600
Height mm 1,000 1,500 1,800 2,000
Width mm 100/150
DISTRIBUTION PAD CELdek® 70120
Length mm 600
Height mm 30
Width mm 100/150
ACCESSORIES: LIGHT FILTERS FOR CELdek®
High light reduction factor.
STANDARD DIMENSIONS
Length mm multiple of 600
Height mm 1,205 1,705 2,005 2,205
Width mm 100/150
STANDARD DIMENSIONS
Model DCP30 TOP4
Length mm 1,640 1,360
Height mm 1,000 1,000
Width mm 1,520 2,500
PERFORMANCES
Airflow at 0 Pa m3/h [cfm] 16,000 [9,415]
Motor power *
kW [hp] 1.1 [1.5]
Cooling efficiency % 83 - 85
DCP30 - TOP4
OUTSIDE TEMPERATURE INSIDE TEMPERATURE
Cooling effect @ 50% RH °C [°F] 34 [93] 27 [81]
30 [86] 23 [73]
26 [79] 20 [68]
* Three-phase electric motor as standard, single phase as options.
Notes: the DCP is intended to be installed outside the building. The cooling effect mentioned above are estimates and can vary based on local conditions.
www.munters.com
Australia Phone +61 2 8843 1594, agh.info@munters.com.au, Brazil Phone +55 41 3317 5050, contato@munters.com, Canada Phone +1 517 676 7070,
aghort.info@munters.com, China Phone +86 10 8048 3493, marketing@munters.cn, Denmark Phone +45 98 623 311, aghort@munters.dk, India Phone
+91 20 6681 8900, info@munters.in, Indonesia Phone +66 2 642 2670, info@munters.co.th, Italy Phone +39 0183 5211, info@munters.it, Japan Phone
+81 3 5970 0021, mkk@munters.jp, Korea Phone +82 2 7618 701, munters@munters.co.kr, Mexico Phone +52 818 2625 400, dhinfo@munters.com,
Singapore Phone +65 7 446 828, info@munters.com.sg, South Africa and Sub-Sahara Countries Phone +27 11 997 2000, info@munters.co.za Spain Phone
+39 0183 5211, info@munters.it, Sweden Phone +46 8 6266 300, info@munters.se, Thailand Phone +66 2 6422 670, info@munters.co.th, Turkey Phone
+90 262 7513 750, info@muntersform.com, USA Phone +1 517 676 7070, aghort.info@munters.com, Export & Other countries Phone +39 0183 5211, info@munters.it
Munters reserves the right to make alterations to specifications, quantities, etc., for production or other reasons, subsequent to publication.
© Munters AB, 2017