PLUG & PLAY HVAC

Meet the most energy efficient HVAC system

OUTSIDE HUMIDITY
35°C 90%
45°C 40%

22º C Inside
PROVIDED BY
HEINEN & HOPMAN

1
Heating Ventilation Air Conditioning Refrigeration
TABLE OF CONTENTS PAGE

COMPANY INTRODUCTION 3

DISCOVER THE PLUG & PLAY HVAC SYSTEM 4
REDUCED ENERGY CONSUMPTION 5
COST SAVINGS 5
SAFE & HEALTHY INDOOR CLIMATE 6
ENERGY SAVINGS UP TO 30% 6
EASY TO CONTROL 7
ADVANTAGES 9

CATALOG 10
NOTE: INSULATION 10
REVERSE CYCLE CHILLERS 11
REVERSE CYCLE CHILLERS - 15 kW MODULE TYPE 12
REVERSE CYCLE CHILLERS - 20 kW MODULE TYPE 13
REVERSE CYCLE CHILLERS - 35 kW MODULE TYPE 14
BLDC REVERSE CYCLE CHILLERS 15
BLDC REVERSE CYCLE CHILLERS - 20 kW MODULE TYPE 17
BLDC REVERSE CYCLE CHILLERS - 35 kW MODULE TYPE 18
REVERSE CYCLE CHILLERS - CONTROL SET 19
CHILLER PUMP SET 23
FAN COIL UNITS 26
FAN COIL UNITS - PFC 27
FAN COIL UNITS - PFC SLIM TYPE 28
FAN COIL UNITS - CONTROL SET 29
FAN COIL UNITS - PFC ROOM THERMOSTAT COVERS 30
FAN COIL UNITS - AIR CONNECTION FITTINGS 31
AIR CONNECTION FITTINGS - SOUND DAMPING FLEXIBLE HOSES 32
AIR CONNECTION FITTINGS - AIR DIVIDERS 33
AIR CONNECTION FITTINGS - OBLONG RINGS 34
FRESH AIR UNITS 35
FRESH AIR UNITS - BASIC 36
FRESH AIR UNITS - ADVANCED 37
FRESH AIR UNITS - CONROL SET 38
CENTRALIZED EXHAUST UNITS 40
CENTRALIZED EXHAUST UNITS - AC TYPE 41
CENTRALIZED EXHAUST UNIT - EC TYPE 42
CENTRALIZED EXHAUST UNIT - EC TYPE HIGH PRESSURE 43
ENGINE ROOM VENTILATION 44
ENGINE ROOM VENTILATION - CONTROL SET 46

91 103 112
0 122 51 #5B6770
0 94 184 #007A33
#005EB8

2 Plug & Play HVAC systems - HEINEN & HOPMAN 2021 © 2


COMPANY INTRODUCTION
Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the
field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who
established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients
using our knowledge and experience by realising the best possible climate control solutions; either fully customised or
with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we
can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very
latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is
its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global
market for maritime climate control solutions in a future-proof way.

Looking for a customized or standard solution? With Heinen & Hopman you will get:
• Energy efficient solutions
• Flexibility because we design, build and service
• Worldwide service points available
• 24/7 availability
• All necessary certificates for global shipping industry operation.

For more information about products & services, case studies and blogs, visit our website www.heinenhopman.com.

OPERATING GLOBALLY

Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to
offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to
us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where
our clients need us to be.

Europe
29
Offices
1250
Employees
8
Factories
13
Countries

Americas Asia
12 240 5 3 16
Offices
320
Employees
6
Factories
7
Countries
Offices Employees Factories Countries

3
DISCOVER THE PLUG & PLAY
REDUCED
HVAC SYSTEM COST
ENERGY
CONSUMPTION SAVINGS
Wheter it be the icy fjords in Norway, or the sunshine
shores of the Caribbean, having a suitable indoor
climate is a must in the world of luxury on vessels.
Heinen & Hopman introduces a line of HVAC products
especially for vessels up to 45 meters.

The Plug & Play system focuses on:


• Reduced energy consumption
• Cost savings
• Safe & healthy indoor climate

The products in this range can be applied to multiple SAFE & HEALTHY
ship types ranging from yachts to trawlers and INDOOR
tugboats. The philosophy is to provide ready-to-use CLIMATE
machines that only need to be connected to the on-
board power panel and chilled water pipes on board.

Thanks to this philosophy, no additional cables or valves


are required as everything is integrated inside the units.
The P&P system is a product line that includes:
• Fan coil units
• Air handling units
• Engine room ventilation
• Reverse cycle chiller units
• Control system

Yards and crew alike benefit from the P&P system,


starting from a new concept of machinery that ensures
smaller service spaces, user-friendly application and fast
component installation and replacement.

Fully remote worldwide assistance is available from


Heinen & Hopman’s offices via a smart cloud system
which monitors and controls every unit parameter.

All necessary HVAC system building instructions are


ready to use and our new technical library can be
consulted anytime. In this dedicated cloud you will find
all the required information to integrate the
HVAC with electrical and hydraulic systems, including
more than 300 drawings.

Inside the library, interior designers can find layouts


and arrangements to interface the HVAC system with
interiors, from supply plenum dimensions to noise
requirements to various examples of how units are
allocated inside furniture classified by space class.

All P&P units have been designed using the latest


technologies. Brushless EC motors installed on fan
coils, air handling units and engine room fans are
designed and manufactured according to IEC-60034
and the related IE-2 regulation (high efficiency). This
future-proofs the P&P system for the time when these
requirements will also be a ‘must’ in the yachting
industry.
4
REDUCED ENERGY CONSUMPTION
Unlike other HVAC systems which rely heavily on the ship’s electric load, the Plug & Play HVAC system is designed to be
energy-efficient, cutting the energy consumption by more than 30%. Other benefits include smaller generators, lower CO2
emissions and a lighter ecological footprint.

Brushles EC motors
This low resistance motor is highly efficient. As well as reducing energy consumption it also attenuates noise and vibration.
The system allows fans to run on variable speeds for maximum energy efficiency.

Measurable quality
Each unit is monitored in real time via our web application exclusively designed for the P&P system. Energy consumption is
considerably reduced due to the new design and technology applications, leading to further cost efficiencies.

Direct seawater cooling


Using the free energy that is available in seawater, direct seawater cooling is a perfect fit in winter and shoulder seasons
when the water is relatively cool and cold demand is not yet as great as in the summer. Discover the full potential seawater
has to offer.

COST SAVINGS
These eco-friendly solutions have a positive effect on the economics of sailing, but this goes hand-in-hand with cutting
cost. Reducing CO2 emissions and saving on fuel consumption are both parts of the same medal. Every gallon of diesel not
needed because the system is so energy efficient is a gallon saved in costs.

Compact design
All Plug & Play components are designed to ensure small dimensions in combination with high efficiency. The compact
design makes it suitable for even the smallest spaces and reduces the total weight of the HVAC installation, which also
contributes to minimising fuel consumption.

Smart monitoring system


The smart monitoring system gives exact data regarding how much energy the HVAC system is consuming. Real-time data
on energy consumption gives you full control and the ability to pinpoint cabins and spaces showing signs of unnecessary
energy consumption.

Quickly available spare parts


Spare parts are easily purchased by means of P&P e-commerce and directly delivered on board all over the world.
Together with the high quality of parts, this lowers the necessity to have lots of spare parts in stock, reducing weight and
fuel consumption.

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


5
SAFE & HEALTHY INDOOR CLIMATE
The wellbeing of passengers and crew is top priority in all cases and this is reflected in the design of the P&P system. Every
possible measure is taken to ensure a fresh and healthy environment, reduce the risk of infection and stop the spread of
diseases.

UV-C purifying system


A UV-C light bulb uses ultraviolet energy to disable viral, bacterial and fungal organisms. A bombardment of highly
energetic particles damages the organisms’ DNA so that they no longer reproduce. And an organism that cannot
reproduce is no longer capable of causing diseases.

Filtering system
The easily cleanable and removable G4 filters take out sand, dust and pollen. The filter is fixed to the air handling unit skid
by means of cleads, facilitating ordinary maintenance operations normally carried out by the crew.

CO2-sensors
A sensor system measures the CO2 percentage, ensuring that it does not come above a pre-set threshold. All rooms and
cabins always have the right amount of fresh outside air, therefore, giving a healthy environment while reducing any
energy waste.

ENERGY SAVINGS UP TO 30%


COMPARED TO TRADITIONAL SYSTEMS

In addition to the benefits of lowering high indirect costs during construction and promising easy integration, user-
friendliness, the Plug & Play product range saves energy compared to a traditional HVAC system. Thanks to the highly
efficient brushless EC motors, the energy consumption is significantly reduced. Below is a situation with a 40 meter yacht.
If you would like us to make a calculation based on your project, please contact us.

Power consumption comparison based on a 40m Yacht

Systems Traditional system P&P system


30 fan coil units 3.8 kW 0.6 kW
4 air handling units 1.8 kW 0.7 kW
4 axial fans 17 kW 14.8 kW
TOTAL 23,4 kW/h 16,1 kW/h

Savings over a 5-year period based on a 40m Yacht

Emission reduction Fuel savings in 1 year Fuel savings in 5 years


-/- 160.448 m CO2
3

greenhouse gas
-/- 11.461 m3 CO
toxic emission ± 15.000 liters ± 75.000 liters
= =
-/- 34.382 m HC
3
-/- € 20,000.- -/- € 100,000.-
pollution
-/- 114.606 m3 NOX
greenhouse effect

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


6
EASY TO CONTROL
Thanks to the included sensors in the Plug & Play system, the interactive air conditioning control platform Aria is available
for the ship builder, owner and the crew. It is available on the web and via a mobile app to take the best advantages from
dedicated services per type of user:
• Shipyards and ship designers can view and download ready-to-use instructions and drawings to integrate the system
in the ship design.
• Chief Engineers can monitor and control the HVAC system remotely. Also, our on-demand service and the e-commerce
platform to find and order spare parts easily are accessible in a click.
• Ship owners can remotely fully control the system according to their wishes.

CLOUD
For system intergra�on on ship design.

APP
E-COMMERCE User friendly.
All your spare parts online available. For owners and chief engineers.

ASSISTANCE TECHNICAL
Voice service, chat, mail, on site. Online technical interface to control all units.
Individual assistance �ckets.

OWNER
Customized and simplified opera�ng modes.
On-board comfort controlled by smarthphone.

7
Mobile app
Via the mobile app you can control your onboard HVAC system easily. It is user friendly and available for owners and
onboard crew.

Images: Mobile app home screens - devices and favourites

Images: Mobile app screens - engine room ventilation and chiller heat pump

Images: Mobile app screens - fan coil unit on and off 8


Desktop app
Via the desktop version of Aria you can control your onboard HVAC system easily. It is user friendly and available for
owners and onboard crew.

Images: Desktop app home screens - devices and favourites

Images: Desktop app screens - engine room ventilation setpoints and overview

Images: Desktop app screens - engine room ventilation analytics

PLUG & PLAY ADVANTAGES


The benefits of choosing for a Heinen & Hopman Plug & Play system:
• Compact units - less space required
• Super silent - more comfort, installation inside furniture (no structural bulkhead)
• Energy saving - lower emissions, smaller generator sets, operative cost reduction
• Inverter free - no THD issue for capacity control
• Indirect cost elimination (during build) - thanks to electrical and hydraulic unit integration
• Operative costs and maintenance operation reduction - thanks to smart thinking solutions
• Design and after sales cost reduction - thanks to Aria, the air conditioning interactive control platform
• Operating modes and customized assets - easy click interface, on-demand assistance, better service to the owner

9
CATALOG
The Plug & Play system is a product line that includes:
• Reverse cycle chiller units
• Fan coil units
• Fresh air units
• Air connection fittings
• Centralized exhaust units
• Engine room ventilation
• Control systems

NOTE: INSULATION
The air conditions are highly dependent on the quality
of the duct installation. Thermal insulation is one of
the most cost-effective improvements to comfort and
efficiency that can be made, because the best way to
beat the heat (or the cold) is to prevent it from ever
getting in. Thermal insulation also tends to muffle
audible noise.

IMPORTANT: Insulation always requires a vapor barrier


to effectively prevent condensation. This means that the
outer surface of the insulation must be impermeable to
water vapor. So it is important to maintain an airtight
vapor barrier around the insulation. The location of
the vapor barrier is also crucial. The insulation must be
between the vapor barrier and the cold surface.

10
REVERSE CYCLE CHILLERS
Each chiller module is factory tested and filled with R-410A. Multiple module skids have been developed and designed
for quick and easy module replacement. Multiple connectors and multi cables are supplied along with the unit and
control panel, making electrical and hydraulic connection on board simple and fast. The compact design and threaded
frames allow the unit to be installed directly with nuts and bolts attached to the ship’s foundation.

If multiple modules of vertical design are required, a skid plug-in is available upon request. Modules
can be assembled in one skid or supplied in separate modules to meet the most demanding space
requirements on board.

Available configurations
• One chilled water and one seawater pump
• Two chilled water and seawater pumps (one system on standby)
• One central switchboard or split with start board for remote pumps
• KNX network interface
• General alarm contact
• Remote start/stop and capacitance reduction contacts

Reverse cycle chillers come with a control panel, pump switches and an optional compressor soft start.

Exchanger SS brazed plates


Condenser Co-axial CuNi
Drip tray SS316L
Frame Painted alu
Compressor type High-efficiency scroll compressor
CW manifolds SS316L
SW manifolds SS316L
Insulation Armaflex
Junction box SS316L
Multiple connectors prot. IP68
Control system PLC type KNX
Touch screen 7” (optional)
Standard painting RAL9010

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


11
REVERSE CYCLE CHILLERS - 15KW MODULE TYPE
Plug & Play 15kW modular reverse cycle chillers are
available with capacities from 15kW (51.700 BTU/h) to
60kW (± 206.900 BTU/h) up to four modules.

Reverse cycle chillers come with a control panel, pump


switches and an optional compressor soft start.

Key features
• Compact design
• Corossion resistant
• Easy installation
• High efficiency
• Environment-friendly

Technical specifications

MODEL Electrical No. of H W L SW CW Icool Iheat


capacity standard stages (mm) (mm) (mm) Ø Ø (A) (A)

PCH15-230 1x230V/50Hz 1 787 550 440 1 ½” 1 ½” 15,08 18,11


43.100 BTU/h
PCH15-400 3x400V/50Hz 1 787 550 440 1 ½” 1 ½” 9,55 10,84
51.700 BTU/h
PCH15-460 3x460V/60Hz 1 787 550 440 1 ½” 1 ½” 8,0 9,25
51.700 BTU/h
PCH30-230 1x230V/50Hz 2 787 550 880 1 ½” 1 ½” 2x 15,08 2x 18,11
86.200 BTU/h
PCH30-400 3x400V/50Hz 2 787 550 880 1 ½” 1 ½” 2x 9,55 2x 10,84
103.400 BTU/h
PCH30-460 3x460V/60Hz 2 787 550 880 1 ½” 1 ½” 2x 8,0 2x 9,25
103.400 BTU/h
PCH45-400 3x400V/50Hz 3 787 550 1.320 1 ½” 1 ½” 3x 9,55 3x 10,84
155.170 BTU/h
PCH45-460 3x460V/60Hz 3 787 550 1.320 1 ½” 1 ½” 3x 8,0 3x 9,25
155.170 BTU/h
PCH60-400 3x400V/50Hz 4 787 550 1.760 1 ½” 1 ½” 4x 9,55 4x 10,84
206.900 BTU/h
PCH60-460 3x460V/60Hz 4 787 550 1.760 1 ½” 1 ½” 4x 8,0 4x 9,25
206.900 BTU/h

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Multiple module

12
REVERSE CYCLE CHILLERS - 20KW MODULE TYPE
Plug & Play 20kW modular reverse cycle chillers are
available with capacities from 20kW (69.000 BTU/h) to
80kW (± 276.900 BTU/h) up to four modules.

Reverse cycle chillers come with a control panel, pump


switches and an optional compressor soft start.

Key features
• Compact design
• Corossion resistant
• Easy installation
• High efficiency
• Environment-friendly

Technical specifications

MODEL Electrical No. of H W L SW CW Icool Iheat


capacity standard stages (mm) (mm) (mm) Ø Ø (A) (A)

PCH20-400 3x400V/50Hz 1 787 550 440 1 ½” 1 ½” 9,93 10,95


69.000 BTU/h
PCH20-460 3x460V/60Hz 1 787 550 440 1 ½” 1 ½” 9,96 11,26
69.000 BTU/h
PCH40-400 3x400V/50Hz 2 787 550 880 1 ½” 1 ½” 2x 9,93 2x 10,95
138.000 BTU/h
PCH40-460 3x460V/60Hz 2 787 550 880 1 ½” 1 ½” 2x 9,96 2x 11,26
138.000 BTU/h
PCH60.2-400 3x400V/50Hz 3 787 550 1.320 1 ½” 1 ½” 3x 9,93 3x 10,95
207.000 BTU/h
PCH60.2-460 3x460V/60Hz 3 787 550 1.320 1 ½” 1 ½” 3x 9,96 3x 11,26
207.000 BTU/h
PCH80-400 3x400V/50Hz 4 787 550 1.760 1 ½” 1 ½” 4x 9,93 4x 10,95
276.000 BTU/h
PCH80-460 3x460V/60Hz 4 787 550 1.760 1 ½” 1 ½” 4x 9,96 4x 11,26
276.000 BTU/h

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Multiple module

13
REVERSE CYCLE CHILLERS - 35KW MODULE TYPE
Plug & Play 35kW modular reverse cycle chillers are
available with capacities from 35kW (120.700 BTU/h) to
140kW (± 482.800 BTU/h) up to four modules.

Reverse cycle chillers come with a control panel, pump


switches and an optional compressor soft start.

Key features
• Compact design
• Corossion resistant
• Easy installation
• High efficiency
• Environment-friendly

Technical specifications

MODEL Electrical No. of H W L SW CW Icool Iheat


capacity standard stages (mm) (mm) (mm) Ø Ø (A) (A)

PCH35-400 3x400V/50Hz 1 980 700 440 2 ½” 2” 21,84 24,37


120.700 BTU/h
PCH35-460 3x460V/60Hz 1 980 700 440 2 ½” 2” 14,46 16,67
120.700 BTU/h
PCH70-400 3x400V/50Hz 2 980 700 880 2 ½” 2” 2x 21,84 2x 24,37
241.400 BTU/h
PCH70-460 3x460V/60Hz 2 980 700 880 2 ½” 2” 2x 14,46 2x 16,67
241.400 BTU/h
PCH105-400 3x400V/50Hz 3 980 700 1.320 2 ½” 2” 3x 21,84 3x 24,37
362.100 BTU/h
PCH105-460 3x460V/60Hz 3 980 700 1.320 2 ½” 2” 3x 14,46 3x 16,67
362.100 BTU/h
PCH140-400 3x400V/50Hz 4 980 700 1.760 2 ½” 2” 4x 21,84 4x 24,37
482.800 BTU/h
PCH140-460 3x460V/60Hz 4 980 700 1.760 2 ½” 2” 4x 14,46 4x 16,67
482.800 BTU/h

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Multiple module

14
REVERSE CYCLE BLDC CHILLERS
Each chiller module is factory tested and filled with R-410A. Multiple module skids have been developed and designed
for quick and easy module replacement. Multiple connectors and multi cables are supplied along with the unit and
control panel, making electrical and hydraulic connection on board simple and fast. The compact design and threaded
frames allow the unit to be installed directly with nuts and bolts attached to the ship’s foundation.

If multiple modules of vertical design are required, a skid plug-in is available upon request. Modules
can be assembled in one skid or supplied in separate modules to meet the most demanding space
requirements on board.

Brushless DC technology ensures maximum overall system efficiency. By varying the compressor speed from 10% to
100% of nominal speed, BLDC chillers always minimize power consumption and maximize onboard comfort, avoiding
typical chilled water temperature fluctuations.

Available configurations
• Speed control on a single module from 10% to 100% of the total available cooling capacity
• Maximum efficiency
• Maximum comfort level in every room served
• One chilled water and one seawater pump
• Two chilled water and seawater pumps (one system on standby)
• One central switchboard or split with start board for remote pumps
• KNX network interface
• General alarm contact
• Remote start/stop and capacitance reduction contacts

Advantages of a BLDC chiller


• Variable speed of the chiller gives maximum comfort compared to a normal on/off chiller by close to 0 fluctuation of
the cooling water temperature
• With a BLDC chiller the efficiency of the compressor is more and more compared to a normal AC compressor (same
principle as a Danfoss Turbocor)
• With a BLDC chiller the capacity control is from 10% to 100% of the available cooling capacity
• With a BLDC chiller the current start up is reduced to 0...! With this solution we have no start peaks at all.
• A perfect integration with battery drive or small electric systems

Reverse cycle BLDC chillers come with a control panel, pump switches and an optional compressor soft start.

Exchanger SS brazed plates


Condenser Co-axial CuNi
Drip tray SS316L
Frame Painted alu
Compressor type High-efficiency BLDC variable speed
CW manifolds SS316L
SW manifolds SS316L
Insulation Armaflex
Junction box SS316L
Multiple connectors prot. IP68
Control system PLC type KNX
Touch screen 7” (optional)
Standard painting RAL9010

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


15
REVERSE CYCLE BLDC CHILLERS
We have tested the BLDC chillers extensively. The results:

Image: Brushless EC motor

Graphic: efficiency with BLDC Graphic: energy consumption

Image: Difference between a non-inverter and an inverter type

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


16
REVERSE CYCLE BLDC CHILLERS - 20KW MODULE TYPE
Plug & Play 20kW modular reverse cycle chillers are
available with capacities from 20kW (69.000 BTU/h) to
80kW (± 276.900 BTU/h) up to four modules.

BLDC Reverse cycle chillers come with a control panel,


pump switches and an optional compressor soft start.

Key features
• Compact design
• Corossion resistant
• Easy installation
• High efficiency
• Environment-friendly

Technical specifications

MODEL Electrical No. of H W L SW CW Icool Iheat


capacity standard stages (mm) (mm) (mm) Ø Ø (A) (A)

PCH20-400 3x400V/50Hz 1 787 550 440 1 ½” 1 ½” 9,93 10,95


69.000 BTU/h
PCH20-460 3x460V/60Hz 1 787 550 440 1 ½” 1 ½” 9,96 11,26
69.000 BTU/h
PCH40-400 3x400V/50Hz 2 787 550 880 1 ½” 1 ½” 2x 9,93 2x 10,95
138.000 BTU/h
PCH40-460 3x460V/60Hz 2 787 550 880 1 ½” 1 ½” 2x 9,96 2x 11,26
138.000 BTU/h
PCH60.2-400 3x400V/50Hz 3 787 550 1.320 1 ½” 1 ½” 3x 9,93 3x 10,95
207.000 BTU/h
PCH60.2-460 3x460V/60Hz 3 787 550 1.320 1 ½” 1 ½” 3x 9,96 3x 11,26
207.000 BTU/h
PCH80-400 3x400V/50Hz 4 787 550 1.760 1 ½” 1 ½” 4x 9,93 4x 10,95
276.000 BTU/h
PCH80-460 3x460V/60Hz 4 787 550 1.760 1 ½” 1 ½” 4x 9,96 4x 11,26
276.000 BTU/h

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Multiple module

17
REVERSE CYCLE BLDC CHILLERS - 35KW MODULE TYPE
Plug & Play 35kW modular reverse cycle chillers are
available with capacities from 35kW (120.700 BTU/h) to
140kW (± 482.800 BTU/h) up to four modules.

BLDC Reverse cycle chillers come with a control panel,


pump switches and an optional compressor soft start.

Key features
• Compact design
• Corossion resistant
• Easy installation
• High efficiency
• Environment-friendly

Technical specifications

MODEL Electrical No. of H W L SW CW Icool Iheat


capacity standard stages (mm) (mm) (mm) Ø Ø (A) (A)

PCH35-400 3x400V/50Hz 1 980 700 440 2 ½” 2” 21,84 24,37


120.700 BTU/h
PCH35-460 3x460V/60Hz 1 980 700 440 2 ½” 2” 14,46 16,67
120.700 BTU/h
PCH70-400 3x400V/50Hz 2 980 700 880 2 ½” 2” 2x 21,84 2x 24,37
241.400 BTU/h
PCH70-460 3x460V/60Hz 2 980 700 880 2 ½” 2” 2x 14,46 2x 16,67
241.400 BTU/h
PCH105-400 3x400V/50Hz 3 980 700 1.320 2 ½” 2” 3x 21,84 3x 24,37
362.100 BTU/h
PCH105-460 3x460V/60Hz 3 980 700 1.320 2 ½” 2” 3x 14,46 3x 16,67
362.100 BTU/h
PCH140-400 3x400V/50Hz 4 980 700 1.760 2 ½” 2” 4x 21,84 4x 24,37
482.800 BTU/h
PCH140-460 3x460V/60Hz 4 980 700 1.760 2 ½” 2” 4x 14,46 4x 16,67
482.800 BTU/h

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Multiple module

18
REVERSE CYCLE CHILLERS - CONTROL SET
Plug & Play controls are designed to be user-friendly, easy to
install and flexible to fit the tightest onboard performances.

Control switchboards are available in different versions


according to the:
• Number of pumps
• Number of chiller modules
• Type of web interface

Key features
• Fast connection
• Easy installation
• 7” touch screen
• PLC control logic
• Remote control
Chillers are controlled and monitored by our specially designed Plug &
Play switchboards that are made according to the number of modules to
be operated. All switchboards are supplied with pre-installed multipole
connectors. This allows for quick and easy installation by simply
connecting the multi cables.

Chiller control systems are fully PLC type. An optional 7” touch screen
can be installed on the switchboard.

The PLC control offers the latest control technologies such as: Image: Air flow diagram with reverse cycle chiller
• Hour counter
• Frost protection
• Low pressure monitoring
• Low/high pressure alarm
• Compressor contactors alarm
• Flow switches
• Chilled water temperature set point heating
• Chilled water temperature set point cooling
• Capacity limit
• Remotely turned off
• General alarm contact
• Smart graphical interface
• Internet LAN connection for remote monitoring and control

Each chiller module control is centralized on the associated switchboard. Chiller control can be achieved through the
following user interfaces:
• Locally via plug-in service tool (standard)
• Local via touch screen panel (optional)
• Via web browser of the on-board internet network (optional)
• Via web browser via internet (optional)
• By smartphone or tablet via the P&P mobile app (optional)
Material Shining painted iron
Touch screen 7” Siemens
Soft starter Contained inside the panels (optional)
Installation Mounting brackets
Electrical connections Multi-cable for chiller modules
Standard painting RAL9010
PLC Siemens Climatix
Aux connection sockets KNX network, Internet LAN, ST LAN
Casing IP class IP54
Multiple connectors IP class IP68 Image: Chiller control installation connection
19
Technical specification

CENTRAL SWITCHBOARDS (INCLUDING PUMP STARTERS)

Electrical Controlled H W L Soft


MODEL
standard stages (mm) (mm) (mm) starter

PCS15-230 1x230V/50Hz N.A.


PCS15-400 3x400V/50Hz 1 506 200 406 Optional
PCS15-460 3x460/60Hz Optional
PCS20-400 3x400V/50Hz 1 506 200 406 Optional
PCS20-460 3x460/60Hz Optional
PCS30-230 1x230V/50Hz N.A.
PCS30-400 3x400V/50Hz 2 606 200 606 Optional
PCS30-460 3x460/60Hz Optional
PCS35-400 3x400V/50Hz 1 606 200 606 Optional
PCS35-460 3x460/60Hz Optional
PCS40-400 3x400V/50Hz 2 606 200 606 Optional
PCS40-460 3x460/60Hz Optional
PCS45-400 3x400V/50Hz 3 806 200 606 Optional
PCS45-460 3x460/60Hz Optional
PCS60-400 3x400V/50Hz 4 806 200 806 Optional
PCS60-460 3x460/60Hz Optional
PCS60.2-400 3x400V/50Hz 3 806 200 606 Optional
PCS60.2-460 3x460/60Hz Optional
PCS70-400 3x400V/50Hz 2 606 200 606 Optional
PCS70-460 3x460/60Hz Optional
PCS80-400 3x400V/50Hz 4 806 200 806 Optional
PCS80-460 3x460/60Hz Optional
PCS105-400 3x400V/50Hz 3 806 200 806 Optional
PCS105-460 3x460/60Hz Optional
PCS140-400 3x400V/50Hz 4 806 200 806 Optional
PCS140-460 3x460/60Hz Optional

Image: Example of a central switchboard including pump starters

20
MAIN SWITCHBOARD and remote pump starter switchboard

Electrical Controlled H W L Soft


MODEL
standard stages (mm) (mm) (mm) starter

PCS30-230-CS 1x230V/50Hz N.A.


PCS30-400-CS 3x400V/50Hz 2 606 200 606 Optional
PCS30-460-CS 3x460/60Hz Optional
PCS30-230-PS 1x230V/50Hz
PCS30-400-PS 3x400V/50Hz 2 506 200 306
PCS30-460-PS 3x460/60Hz
PCS35-400-CS 3x400V/50Hz 1 606 200 606 Optional
PCS35-460-CS 3x460/60Hz Optional
PCS35-400-PS 3x400V/50Hz 1 506 200 306
PCS35-460-PS 3x460/60Hz
PCS40-400-CS 3x400V/50Hz 2 606 200 606 Optional
PCS40-460-CS 3x460/60Hz Optional
PCS40-400-PS 3x400V/50Hz 1 506 200 306
PCS40-460-PS 3x460/60Hz
PCS45-400-CS 3x400V/50Hz 3 806 200 606 Optional
PCS45-460-CS 3x460/60Hz Optional
PCS45-400-PS 3x400V/50Hz 3 506 200 306
PCS45-460-PS 3x460/60Hz
PCS60-400-CS 3x400V/50Hz 4 806 200 806 Optional
PCS60-460-CS 3x460/60Hz Optional
PCS60-400-PS 3x400V/50Hz 4 506 200 306
PCS60-460-PS 3x460/60Hz
PCS60.2-400-CS 3x400V/50Hz 3 806 200 606 Optional
PCS60.2-460-CS 3x460/60Hz Optional
PCS60.2-400-PS 3x400V/50Hz 3 506 200 306
PCS60.2-460-PS 3x460/60Hz
PCS70-400-CS 3x400V/50Hz 2 606 200 606 Optional
PCS70-460-CS 3x460/60Hz Optional
PCS70-400-PS 3x400V/50Hz 2 506 200 306
PCS70-460-PS 3x460/60Hz
PCS80-400-CS 3x400V/50Hz 4 806 200 806 Optional
PCS80-460-CS 3x460/60Hz Optional
PCS80-400-PS 3x400V/50Hz 4 506 200 306
PCS80-460-PS 3x460/60Hz
PCS105-400-CS 3x400V/50Hz 3 806 200 806 Optional
PCS105-460-CS 3x460/60Hz Optional
PCS105-400-PS 3x400V/50Hz 3 506 200 306
PCS105-460-PS 3x460/60Hz
PCS140-400-CS 3x400V/50Hz 4 806 200 806 Optional
PCS140-460-CS 3x460/60Hz Optional
PCS140-400-PS 3x400V/50Hz 4 506 200 306
PCS140-460-PS 3x460/60Hz

Image: PCS-CS Image: PCS-PS

21
Image: Example of a main switchboard and remote pump starter

22
CHILLER PUMP SET
Plug & Play chillers can be supplied with a wide range of
seawater and chilled water pumps specially designed for
marine applications and fully integrated into the chiller
controls.

Spare parts and consumables can be easily purchased


through the E-commerce platform and delivered directly on
board around the world.

Key features
• Compact design
• Heavy duty
• Internal design
• Reliability
• Custom execution
Plug & Play non-self-priming seawater and chilled water pumps are
integrated into the reverse cycle control panel to provide a turnkey control
system and make installation quick and easy.

Seawater pumps have a bronze housing and impeller to ensure longer life
and maintenance time. Specific widia ceramic compounnd for mechanical
seals is supplied as standard for seawater pumps. Seawater pumps must
be installed below seawater level. Pump motors have an IP55 Class F
protection, tropical version.
Image: Seawater pump
The Plug & Play pump design ensures small dimensions combined with maximum efficiency. The mechanical internal
layout has been developed to ensure that all parts that come into contact with liquids are sized to withstand the most
demanding mechanical loads a pump may face during its lifetime.

Every rotating part is protected from the outside to prevent any possible contact with operators on board. The shaft
bearings are designed to reduce stress and provide high reliability under all pump operating conditions.

A wide range of customization is possible, ranging from flow and head characteristics to the final required color
according to the vessel’s specifications.
Sea water pumps Chilled water pumps
Pump body Bronze Pump body Cast iron
Impeller Bronze Impeller Brass / Cast iron
Shaft AISI316 Shaft AISI303
Protection IP55 Protection IP55
Execution Tropicalized Execution NA
Seals Widia Ceramix (XYXYRZY) Seals Widia Ceramic/EPDM
Color According request Color According request

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

23
Technical specification

Seawater pumps

Available Instal- H W L Flow/ Speed Inlet Out- Inlet Outlet Weight


MODEL standard led (mm) (mm) (mm) Head (RPM) Ø let con. con. (kg)
capacity power (m3/h / Ø (exec.) (excl.)
(kW) m.w.c.)

SW15.20-230 1x230V/50Hz 0,37 260 167 380 2,4 / 7,50 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 69.000 BTU/h
SW15.20-400 3x400V/50Hz 0,37 260 167 380 2,4 / 7,50 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 69.000 BTU/h
SW15.20-460 3x460V/50Hz 0,37 260 167 380 2,4 / 7,50 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 69.000 BTU/h
SW30-230 1x230V/50Hz 0,37 260 167 380 4,8 / 7,80 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 103.400 BTU/h
SW30-400 3x400V/50Hz 0,37 260 167 380 4,8 / 7,80 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 103.400 BTU/h
SW30-460 3x460V/50Hz 0,37 260 167 380 4,8 / 7,80 1.450 G 1 ½” G 1” Threated Threated 17,5
Up to 103.400 BTU/h
SW35.40-400 3x400V/50Hz 0,37 292 240 410 8 / 7,20 1.450 DN50 DN32 Flanged Flanged 30,5
Up to 138.000 BTU/h
SW35.40-460 3x460V/50Hz 0,37 292 240 410 8 / 7,20 1.450 DN50 DN32 Flanged Flanged 30,5
Up to 138.000 BTU/h
SW45-400 3x400V/50Hz 0,37 305 250 385 6,6 / 9,5 1.450 G 1 ½” G 1” Threated Threated 21,5
Up to 152.100 BTU/h
SW45-460 3x460V/50Hz 0,37 305 250 385 6,6 / 9,5 1.450 G 1 ½” G 1” Threated Threated 21,5
Up to 152.100 BTU/h
SW60-400 3x400V/50Hz 0,55 230 173 313 8,4 / 16,3 2.900 G 1 ½” G 1” Threated Threated 13,5
Up to 202.800 BTU/h
SW60-460 3x460V/50Hz 0,55 230 173 313 8,4 / 16,3 2.900 G 1 ½” G 1” Threated Threated 13,5
Up to 202.800 BTU/h
SW80-400 3x400V/50Hz 0,75 292 242 450 16,8 / 8 1.450 DN65 DN40 Flanged Flanged 43
Up to 276.000 BTU/h
SW80-460 3x460V/50Hz 0,75 292 242 450 16,8 / 8 1.450 DN65 DN40 Flanged Flanged 43
Up to 276.000 BTU/h
SW105-400 3x400V/50Hz 1,1 272 209 423 24 / 9 2.900 G 2 ½” G 2 ½” Threated Threated 29,2
Up to 362.100 BTU/h
SW105-460 3x460V/50Hz 1,1 272 209 423 24 / 9 2.900 G 2 ½” G 2 ½” Threated Threated 29,2
Up to 362.100 BTU/h
SW140-400 3x400V/50Hz 1,1 272 209 423 32 / 8 2.900 G 2 ½” G 2 ½” Threated Threated 29,2
Up to 482.800 BTU/h
SW140-460 3x460V/50Hz 2,2 252 212 453 25 / 18 2.900 G 2 ½” G 2 ½” Threated Threated 29,2
Up to 482.800 BTU/h

NOTE:
Pumps are selected according to the standard sizing parameter. Correct measurements must be carried out for each project before purchase.
For other products of this type, specific customization requests, please contact: info@it.heinenhopman.com.

24
Technical specification

Chilled water pumps

Available Instal- H W L Flow/ Speed Inlet Out- Inlet Outlet Weight


MODEL standard led (mm) (mm) (mm) Head (RPM) Ø let con. con. (kg)
capacity power (m3/h / Ø (exec.) (excl.)
(kW) m.w.c.)

CW15.20-230 1x230V/50Hz 0,15 160 122 266 2,4 / 3,6 2.900 G ½” G ½” Threated Threated 5,2
Up to 69.000 BTU/h
CW15.20-400 3x400V/50Hz 0,15 160 122 266 2,4 / 3,6 2.900 G ½” G ½” Threated Threated 5,2
Up to 69.000 BTU/h
CW15.20-460 3x460V/50Hz 0,15 160 122 266 2,4 / 3,6 2.900 G ½” G ½” Threated Threated 5,2
Up to 69.000 BTU/h
CW30-230 1x230V/50Hz 0,37 168 149 263 4,8 / 9 2.900 G 1” G ½” Threated Threated 6,8
Up to 103.400 BTU/h
CW30-400 3x400V/50Hz 0,37 168 149 263 4,8 / 9 2.900 G 1” G ½” Threated Threated 6,8
Up to 103.400 BTU/h
CW30-460 3x460V/50Hz 0,37 168 149 263 4,8 / 9 2.900 G 1” G ½” Threated Threated 6,8
Up to 103.400 BTU/h
CW35.40-400 3x400V/50Hz 0,55 193 240 380 8 / 7,0 2.900 G 1 ½” G 1 ½” Threated Threated 11,8
Up to 138.000 BTU/h
CW35.40-460 3x460V/50Hz 0,55 193 240 380 8 / 7,0 2.900 G 1 ½” G 1 ½” Threated Threated 11,8
Up to 138.000 BTU/h
CW45-400 3x400V/50Hz 0,45 190 171 263 6,6 / 7,5 2.900 G 1 ½” G 1” Threated Threated 8,3
Up to 152.100 BTU/h
CW45-460 3x460V/50Hz 0,45 190 171 263 6,6 / 7,5 2.900 G 1 ½” G 1” Threated Threated 8,3
Up to 152.100 BTU/h
CW60-400 3x400V/50Hz 0,55 230 173 313 8,4 / 16,3 2.900 G 1 ½” G 1” Threated Threated 13,5
Up to 202.800 BTU/h
CW60-460 3x460V/50Hz 0,55 230 173 313 8,4 / 16,3 2.900 G 1 ½” G 1” Threated Threated 13,5
Up to 202.800 BTU/h
CW80-400 3x400V/50Hz 0,75 250 168 391 13 / 15 2.900 G 2” G 1 ¼” Threated Threated 18,8
Up to 276.000 BTU/h
CW80-460 3x460V/50Hz 0,75 250 168 391 13 / 15 2.900 G 2” G 1 ¼” Threated Threated 18,8
Up to 276.000 BTU/h
CW105-400 3x400V/50Hz 1,5 270 207 420 20 / 12 2.900 G 2 ½” G 2 ½” Threated Threated 23,2
Up to 362.100 BTU/h
CW105-460 3x460V/50Hz 1,5 270 207 420 20 / 12 2.900 G 2 ½” G 2 ½” Threated Threated 23,2
Up to 362.100 BTU/h
CW140-400 3x400V/50Hz 2,2 252 212 453 25 / 18 2.900 DN65 DN40 Flanged Flanged 32
Up to 482.800 BTU/h
CW140-460 3x460V/50Hz 2,2 252 212 453 25 / 18 2.900 DN65 DN40 Flanged Flanged 32
Up to 482.800 BTU/h

NOTE:
Pumps are selected according to the standard sizing parameter. Correct measurements must be carried out for each project before purchase.
For other products of this type, specific customization requests, please contact: info@it.heinenhopman.com.

25
Image: Chilled water pump
FAN COIL UNITS
PFC fan coil units feature the ultimate technologies available in the marine HVAC market. Super quiet EC fan blowers
allow fans to be installed in furniture without any risk of environmental noise pollution from engine noise.

Plug & Play brushless technology and latest aerodynamic design make the PFC fan coil unit the most efficient terminal
unit available on the market. Specially designed vibration dampers provide a vibration-free environment allowing
installation of the units in the most unusual and sensitive areas.

Key features
• Compact design
• Quick installation
• Super silent
• Vibration free
• High efficiency

PFC fan coil units are supplied with all water valves installed in the unit, including:
• Electrically operated three way valve
• Flow balancing valves
• Closing valves

A dedicated vent valve is connected to the top end of the water coil, allowing quick and easy cleaning of chilled / hot
water loop during system start-up or cleaning.

A built-in junction box with multiple connectors is fitted to the top case, allowing quick connection to the room
thermostat controller. A specially designed Heinen & Hopman multi cable with quick couplings is part of the power
supply for power and control connection. Cable lengths according to the requirements on board. The touchscreen
controller provides a user-friendly interface. PFC fan coil units can be fully monitored and controlled by a simple KNX
network. Each individual speed step can be set individually based on the actual system pressure drop.

Notes
• Refer to the fan coil control section of this document for the full fan coil + control package.
• The stated weights are subject to change depending on the electric heater layout chosen by the customer.
• Fully adjustable fan rotation.
• Fan with water connection on the right.
• For electric heating above 1,5 kW, an external switch must be added by the customer.

Drip tray Special treated galvanized


Drain connection 2x3/8” threated*
Tray color Black
Fan type High efficiency EC fan
Water coil Cu/Al
Water connections Threated
Electric heater Stainless steel
Air filter NEO
Multiple connectors IP68 on fan coil
Control system Refer to related chapter
Standard execution Total black
Vibration damper (PFC type) Position adjustable
Vibration damper (Slim type) Adjustable horizontally

* For sailing vessel N.4 drain connection will be provided.

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


26
FAN COIL UNITS - PFC
Plug & Play fan coil units are available from 6.000 to 24.000
BTU/h.

Each fan coil unit is supplied with its own pre-wired multi-
cable and a touchscreen thermostat controller for a plug and
play installation.

CW control, balancing and closing valves are already installed


in the skid!

Technical specifications

M.U. PFC6 PFC9 PFC12 PFC18 PFC24


SPECIFICATIONS

Cooling cap.* BTU/h 6.000 9.000 12.000 18.000 24.000


Heating cap. (by water)** BTU/h 6.500 10.250 12.600 18.100 23.500
Power consumption (Max RPM) W 83 83 115 165 165
Power consumption (50% Qnom) W 13 13 19 27 27
Power consumption (30% Qnom) W 4 4 6 10 13
Heating Cap. (Electr. heater)*** kW 1 1 1/1,5 1/1,5 1/1,5
Water flow (10% Eth. glycol) l/h 315 465 621 907 1.219
Air flow m3/h 390 500 575 750 950
AESP at max. RPM Pa 331 165 203 374 180
Length mm 415 465 465 540 620
Depth mm 400 400 400 452 452
Height mm 358 383 383 415 482
Supply Air connection D mm 125 125 125 160 160
Weight Kg 10,5 12,5 14,0 21,0 23,5
Water connections DN ½” ½” ½” ¾” ¾”
* Water trace 7 C/12 C
0 0

** Water trace 450/N.D.


*** Electric heater power available according requests up to 2x2 kW

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: PFC18 fan coil unit

27
FAN COIL UNITS - PFC SLIM TYPE
Plug & Play fan coil units are available from 6.000 to 24.000
BTU/h.

Each fan coil unit is supplied with its own pre-wired multi-
cable and a touchscreen thermostat controller for a plug and
play installation.

Electric standards available:


• 1x230V - 50/60Hz
• 1x115V - 50/60Hz (for sailing vessel N.4 drain connection
will be provided)

Technical specifications

M.U. PFC6 PFC9 PFC12 PFC18 PFC24


SPECIFICATIONS

Cooling cap.* BTU/h 6.000 9.000 12.000 18.000 24.000


Heating cap. (by water)** BTU/h 6.500 10.250 12.600 18.100 23.500
Power consumption (Max RPM) W 83 83 115 165 165
Power consumption (50% Qnom) W 13 13 19 27 27
Power consumption (30% Qnom) W 4 4 6 10 13
Heating Cap. (Electr. heater)*** kW 1 1 1/1,5 1/1,5 1/1,5
Water flow (10% Eth. glycol) l/h 315 465 621 907 1.219
Air flow m3/h 390 500 575 750 950
AESP at max. RPM Pa 331 165 203 374 180
Length mm 415 465 465 540 620
Depth mm 279 279 279 309 309
Height mm 620 665 665 820 820
Supply Air connection D mm 125 125 125 160 160
Weight Kg 11,5 13,95 15,75 24,0 27,9
Water connections DN ½” ½” ½” ¾” ¾”

* Water trace 70C/120C


** Water trace 450/N.D.
*** Electric heater power available according requests up to 2x2 kW

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: PFC18 fan coil unit slim type

28
FAN COIL UNITS - CONTROL SET
The Plug & Play PFC fan coil unit control set offers the customer all
necessary control and power equipment to work with the PFC fan coil
unit. Thanks to simple click connections and the special design of the
thermostat installation, the PFC fan coil unit control set easy to adapt
to any type of interior. The thermostat controller is pre-programmed
to control any PFC fan coil unit configuration.

Electric standards available: Key features


• 1x230V - 50/60Hz • Modern design
• 1x115V - 50/60Hz (for sailing • Touchscreen
vessels N.4 drain connection will be
• User-friendly
provided) • Pre-programmed
• Prewired
The special design of our room thermostat controller allows for easy installation for all carpentry configurations. The
display can be hidden in the furniture or supplied with custom aesthetic plates made according to the interior design
(optionally available).

The main features have been developed to ensure


a user-friendly interface according to the ultimate
technologies available in the market:
• Room temperature control via built-in
temperature sensor or external air sensor
• DIP switches control
• KNX bus configuration
• Pre-selected working mode (comfort,
economy, long conservation)
• Independent function for window contact or
presence detector
• Automatic or manual fan speed control
• Automatic cooling/heating changeover
• Display of current temp. and setpoint in °C and/or °F
• Key lock function
• Filter cleaning reminder
• Time planning and central control of setpoints via KNX bus

The special Heinen & Hopman design multi-cable is Touch screen dimensions 66,80 (L) x 56,80 (H) mm
supplied pre-wired to the controller terminal for plug- Related voltage AC 230V
and-play installation. Overvoltage cat. III
Power consumption 2,1 W
On-board wiring is only limited to KNX network if KNX bus interface TP1-64 electrically isolated
required and power supply. No junction box is required Bus current 5mA
between the room controller and the fan coil units. Measuring range 00C to 490C
This makes the PFC FANCOIL unit control replaceable Accuracy < ± 0,5K
within a click in case of damages.

Image: Room thermostat Image: Mounting frame

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm. 29
FAN COIL UNITS - PFC ROOM THERMOSTAT COVERS
PFC FANCOIL thermostats can be supplied with a wide range of cover
plates to suit all cases where the display needs to be placed visibly and
specific covers are required to match the interior design.

3D printing enables custom covers according to the wishes of the


interior designer and in agreement with the main interior builders.

Final color, gloss effects, logos and ship names can be implemented
without limitation.
Industrialized 3D printing allows for any adjustment of thermostat covers if the standard touchscreen plate does not
match a vessel’s interior design.

Many types of colors and surface finishes are available on request, including ship logo and ship name.

If desired, the cover can also be manufactured according to the main brands.

30
FAN COIL UNITS - AIR CONNECTION FITTINGS
PFC FANCOIL unit air connection fittings ensure that the onboard installation is
carried out to the highest standards.

A good air connection to the internal supply plenums is the basis for a high-
quality installation.

PFC FANCOIL fittings are the basis for realizing the best comfort air network
according to the available spaces on board.

Installation kits for supply air connections mainly consists of:


• Sound-damping, pre-insulated flexible hoses
• Air divider
• Elongated air connectors for plenum supply

High quality sound damping flexible hoses, 3D printing elongated connections together with air dividers provide all
necessary parts/components for a perfect system according to the highest installation standard.

Super quiet PFC FANCOIL and PFC supply air connection fittings are the
perfect match to provide a super silent HVAC system, even when duct
space is very limited.

Image: Flexible duct Images: 3D printed air duct connections

31
AIR CONNECTION FITTINGS - SOUND DAMPING FLEXIBLE HOSES
Pre-insulated flexible hose realized with internal sound-absorbing
perforating flexible duct. Insulation is achieved by using a 25 mm
thick fiberglass mat and an additional outer layer of vapour-tight
aluminum foil.

Available in diameter from 76 to 610 mm, fully non-combustible


certified by class.

Key features
• High noise reduction
• High resistance
• Certified for all marine applications
Technical specifications

Fire resistance Incombustible


Internal Eternal
MODEL diameter diameter Max air speed 30 m/s
(mm)* (mm)* Max pressure 300mm H2O
Max bending 0,8 D
PFC100FLEX 102 152
Minimum ordering length 10m
PFC125FLEX 127 177
Insulation thickness 25mm
PFC160FLEX 160 210
Insulation density 16 kg/m3
PFC200FLEX 203 253
PFC250FLEX 254 304

* More sizes available on request.

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.

32
AIR CONNECTION FITTINGS - AIR DIVIDERS
Special care has been taken in the design of our 3D printed air
dividers to create the best solution to distribute PFC FANCOIL supply
airflow into more branches without creating additional turbulence,
making the use of air dividers almost silent. The flexibility offered by
the latest 3D printing technology enables a special design never seen
before in the marine HVAC market.

Key features
• Special design
• Wide range
• Great strength
Technical specifications

Inlet Outlet Outlet L W H


MODEL diameter diameter 1 diameter 2 (mm) (mm) (mm)
(mm) (mm) (mm)

PFCDIV125.100.100 125 100 100 196 146 175


PFCDIV125.125.125 125 125 125 258 148 201
PFCDIV160.100.100 160 100 100 196 174 160
PFCDIV160.125.125 160 125 125 248 174 192
PFCDIV160.160.125 160 160 125 278 183 209
PFCDIV160.160.160 160 160 160 303 183 222
PFCDIV125.125.125 125 slim 125 125 315 72 236

NOTE:
Above dividers are the most common according PFC unit dimensions.
Different sizes available upon request!

HDT 1050C
Tensile strength 40 MPa
Strain at break 47%
Tensile module 4000 MPa
Impact strength 43 Kj/m2
Specific weight 1,27 g/cm3

Images: 3D printed air dividers

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.

33
AIR CONNECTION FITTINGS - OBLONG RINGS
3D printed air ring for plenum connection duct supply. When designing
elongated rings, special attention has been paid to connecting flexible
supply air hoses to indoor plenums when normal round nipples are too
large to allocate the available height.

A small angle is given to horizontal surfaces, this allows safe installation


of flexible hoses even in the most critical cases where connection is
very difficult due to limited space.

Key features
• Special design
• Easy connection
• Limited space fitting
Technical specifications
Max air speed 30 m/s
Flex duct internal Equivalent
MODEL diameter (mm) minimum height Max pressure 300mm H2O
(mm) Minimum order quantity 50 pcs

PFCOR100 100 79
PFCOR125 125 82
PFCOR160 160 106
PFCOR200 200 133
PFCOR250 250 166

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm. Images: 3D printed oblong rings

34
FRESH AIR UNITS
The Heinen & Hopman plug-and-play fresh air units are equipped with the most recent technologies available on the
market for marine HVAC systems. Super quiet EC fan blowers allow the Fresh Air units to be installed in carpentry
without any risk of environmental noise pollution caused by engine noise.

The Plug & Play brushless technology and latest aerodynamic design make the Fresh Air units one of the most efficient
air handling units on the market. Specially designed vibration dampers provide a vibration-free environment allowing
installation of the units in the most unusual and sensitive areas. The Advanced models are also equipped with a high-
tech heating element control system.

Fresh Air units are supplied with all water valves installed in the unit, including electrically operated three-way valve,
flow control valves and shut-off valves.

The Fresh Air units are mainly consists of the following sections:
• Filter section
Easily removable and cleanable G4 filter. The filter is cleat-mounted to the air handler skid, facilitating the normal
maintenance normally performed by the crew.

• Cooling/Heating
Copper tube coil and aluminum fin construction, suitable for chilled water as cooling medium or hot water as
heating medium. The coil is protected with a special cataphoresis coating treatment. Coil casing and drain tank
supplied in SS316L.

• Fan section
High-efficiency EC plug fan mounted on flexible connections to prevent transfer to the skid. The fan is equipped
with a special electronic board mounted directly in the electric motor. The fan speed can be adjusted during
commissioning according to the final pressure losses of the fresh air system. The fresh air supply ducts can be
connected directly to the fan section on three different sides of the unit, facilitating the construction of compact fan
rooms and avoiding the installation of an additional distribution section.

• Electric heating section (applies to Advanced models only)


This section contains an electric heater with an SS304 housing and SS304 electrical elements. The heater includes
maximum temperature protection and flow switch.

A pre-wired built-in junction box with multiple Frame material Aluminum


connectors is provided in the housing. This Frame finishing Painted RAL9010 (including corners)
allows a Plug & Play electrical connection to External panels Galvanized
the controller of the fresh air unit. Each unit External finishing Painted RAL9010 is
supplied complete with a specially designed Internal panels Stainless steel INOX AISI 304
Heinen Hopman multi-cable for control and Internal panels finishing Passivated
power connection with cable lengths according Panels insulation 25mm Rina approved Paroc (100 kg/m3)
to the requirements on board. Foundation Not necessary
Foundation finishing Threaded rivets for fastening marine foundations
Key features Filter type G4
• Compact design Drip tray Stainless steel INOX AISI 316 L
• Quick installation
Cooling coil case Stainless steel INOX AISI 316 L
• Super silent
Cooling coil Cu/Al with special cataphoresis coating
• Vibration free
Electrical re-heater* IP55 stainless steel INOX AISI 304
• High efficiency
Mist eliminator* PPTV
Fan EC centrifugal module RadiCal - Plug Fan
*Applies to Advanced models only
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


35
FRESH AIR UNITS - BASIC
The basic fresh air unit is especially designed for cooling/heating
control and manufactured to the highest quality standards for marine
HVAC applications.

Built-in junction box, three-way valves, shut-off valves and control


valves make the basic fresh air units ready for electrical and hydraulic
connection without additional running cables or hydraulic components.

Electric standards available:


• 1x230V - 50/60Hz
• 1x115V - 50/60Hz

Technical specifications

M.U. BSC 250 BSC 500 BSC 750


SPECIFICATIONS

Cooling capacity kW 4,23 8,7 13,0


Heating capacity kW 5,15 10,27 15,33
Installed power (fan) kW 0,169 0,169 2x0,169
Power consumption (fan) W 55 107 190
Water flow (10% Eth. glycol) l/h 608 1.258 2.232
Air flow m3/h 250 500 750
Static pressure Pa 300 300 300
Length mm 710 710 810
Width mm 490 540 850
Height mm 435 470 490
Connections (C) mm 97 97 97
Chilled/Hot water connections DN ½” ¾” 1”
Drain connection (N.2) DN 25 25 25
Locks and handles Type Black plastic Black plastic Black plastic

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Basic fresh air unit BSC 250

36
FRESH AIR UNITS - ADVANCED
The advanced fresh air unit is especially designed for cooling/heating/
humidity control and manufactured to the highest quality standards for
marine HVAC applications.

Built-in junction box, three-way valves, shut-off valves and control


valves make the advanced fresh air units ready for electrical and
hydraulic connection without additional running cables or hydraulic
components.

Electric standards available:


• 3x400V - 50/60Hz
• 3x460V - 50/60Hz
Technical specifications

M.U. ADV 250 ADV 500 ADV 750


SPECIFICATIONS

Cooling capacity kW 6,2 12,5 19,0


Heating capacity kW 5,74 11,44 17,0
Electrical post-heater kW 2,0 3,7 5,6
Installed power (fan) kW 0,169 0,169 2x0,169
Power consumption (fan) W 74 124 220
Water flow (10% Eth. glycol) l/h 894 1.013 2.690
Air flow m /h
3
250 500 750
Static pressure Pa 300 300 300
Length mm 1.110 1.110 1.200
Width mm 490 540 850
Height mm 435 470 470
Connections (C) mm 97 97 97
Chilled/Hot water connections DN ½” ¾” 1”
Drain connection (N.2) DN 25 25 25
Locks and handles Type Black plastic Black plastic Black plastic

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
Refer to the appropriate chapter for information about the control set.

Image: Advanced fresh air unit ADV 250

37
FRESH AIR UNITS - CONTROL SET
Plug & Play controls are designed to be user-friendly, easy to install and flexible to fit
the tightest onboard performances.

The fresh air unit control switchboards are supplied with prewired multi-pole
connectors and a multi-cable specially designed for powering and controlling Plug &
Play fresh air systems.

Available electrical standards: Key features


• 1x230V - 50Hz • Quick cabling
• 1x115V - 60Hz • Easy installation
• 3x400V - 50/60Hz • Compact dimensions
• 3x460V - 50/60Hz • PLC control logics
• Remote control
Plug & Play fresh air units are controlled and monitored by our specially designed P&P switchboards that are realized
according to the number of fresh air units to be controlled. All switchboard come with pre-installed multi-pole
connectors. This allows for quick and easy installation by simply connecting the multi cables.

Fresh air unit control systems are fully PLC type and a service tool quick
connect plug is installed on the front of each panel. The PLC control
offers the latest control and protection technologies such as:
• Hour counter (with auto-advise for maintenance) Image: Heinen & Hopman fresh air unit
• Frost protection
• Overheating protection
• Filter pressostat
• Chilled/hot water inlet temperature sensor
• Treated air trap temperature sensors
• Three-way valve control
• Remotely turned off
• General alarm contact
• Modern and smartly designed graphical interface
• Internet LAN connection for remote monitoring and control Image: Fresh ait unit control installation connection

Each control of the fresh air unit is centralized on the associated switchboard. The control of each unit can be made
from four different control stations:
• Locally via plug-in service tool (standard)
• Via web browser from the on-board internet network (optional)
• Via web browser via the internet (optional)
• By smartphone or tablet via the P&P mobile app (optional)
Material Shining painted iron
Local interface P&P service tool
Control type PLC
Installation Mounting brackets
Electrical connections Multi-cable for fresh air units
Standard painting RAL9010
PLC Siemens Climatix
Aux connection sockets KNX network, Internet LAN, ST LAN
Casing IP class IP54

38
Technical specifications

Electrical Control interface H W L


MODEL
standard (mm) (mm) (mm)

1x230V/50Hz Plug-in service tool 395 200 295


PFCBB
1x115V/60Hz
3x400V/50Hz Plug-in service tool 510 200 400
PFCBA
3x460V/60Hz

Image: Basic type switchboard Image: Advanced type switchboard

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.

39
CENTRALIZED EXHAUST UNITS
Plug & Play centralized exhaust units are the perfect combination to provide the right exhaust system for
accommodations in P&P HVAC system applications. Each unit is built with sound attenuating internal perforated
sandwich panels.

Models
The centralized exhaust units are available in three models:
• AC type
• EC type
• EC type high pressure

Available electrical standards:


• 1x230V - 50Hz
• 1x115V - 60Hz
Frame material Aluminum
Frame finishing Painted RAL9010 (including corners)
External panels Galvanized
External finishing Painted RAL9010
Internal panels Sound attenuating perforated panels
Internal panels finishing Inox
Panel insulation 25mm Rina approved Paroc (100 kg/m3)
Foundation Not necessary
Fan AC model 5 speeds high efficiency fan
Fan EC models High efficiency EC fan

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


40
CENTRALIZED EXHAUST UNITS - AC TYPE
Plug & play centralized AC exhaust units come with a 5-speed exhaust fan.

Manufactured with sound attenuating sound panels, exhaust units can be placed
in more critical areas where respecting noise requirements is a must. Each motor is
equipped with 5 different speeds to match the actual pressure loss in the ducting
system. The final operating speed is adjusted during commissioning to ensure that
the design airflows are respected.

Key features
• Fast cabling
• Versatile
• Silent blower
Technical specifications

Air flow Statis pressure I P RPM H W L


MODEL
(m3/h) (Pa) (A) (W) (mm) (mm) (mm)

EXH CET AC
Speed 1 265 165 1,04 230 1475 410 450 410
EXH CET AC
Speed 2 350 288 1,03 222 1980 410 450 410
EXH CET AC
Speed 3 415 410 1,03 210 2340 410 450 410
EXH CET AC
Speed 4 450 478 1,06 209 2525 410 450 410
EXH CET AC
Speed 5 500 550 1,21 253 2705 410 450 410

NOTE: The information in the table refers to 1x230V/50Hz execution. Max. capacity up to 1235m3/h with 215 Pa SP.

41
CENTRALIZED EXHAUST UNITS - EC TYPE
Plug & play centralized EC exhaust units come complete with super quiet, highly
efficient EC fans.

Super-quiet EC blowers and noise-reducing sound sound panels allow the installation
of EC exhaust units in carpentry, eliminating any risk of environmental noise pollution
due to engine noise. Further brushless technology and the latest aerodynamic design
make the P&P exhaust unit one of the most efficient units available on the market.
The final operating speed is adjusted during commissioning to ensure that the design
airflows are respected. The units are controlled directly from our fresh air control
system*, while stand-alone installations require a control potentiometer.
*Power to be supplied by the ship’s power system, controlled by the fresh air control
system - only if purchased in combination.

Key features
• Compact design
• Quick installation
• Super silent
• Vibration-free
• Very efficient
Technical specifications

Air flow Statis pressure P H W L


MODEL
(m3/h) (Pa) (W) (mm) (mm) (mm)

250 300 50 340 500 500


250 800 169 340 500 500
EXH CET
500 300 90 340 500 500
EC
500 550 169 340 500 500
750 300 169 340 500 500

42
CENTRALIZED EXHAUST UNITS - EC TYPE HIGH PRESSURE
Plug & play centralized EC exhaust units come complete with super quiet, highly
efficient EC fans.

Extreme versions allow for high airflow capacities with the minimum available space
to allocate the fan. On the other hand, special care should be taken to place this fan
on board because of the noise emission caused by high capacities and tight spaces.
Brushless technology and the latest aerodynamic design make the P&P exhaust unit
one of the most efficient units available on the market. The final operating speed
is adjusted during commissioning to ensure that the design airflows are respected.
The centralized EC exhaust units are controlled directly from our fresh air control
system*, while stand-alone installations require a control potentiometer.
*Power to be supplied by the ship’s power system, controlled by the fresh air control
system - only if purchased in combination.

Key features
• Compact design
• Quick installation
• Super silent
• Vibration-free
• Very efficient
Technical specifications

Air flow Statis pressure P H W L


MODEL
(m3/h) (Pa) (W) (mm) (mm) (mm)

750 400 180 370 640 640


750 1300 750 370 640 640
1000 400 250 370 640 640
EXH CET 1000 1250 750 370 640 640
EC-HP 1250 400 500 370 640 640
1250 1100 750 370 640 640
1500 400 380 370 640 640
1500 900 750 370 640 640

43
ENGINE ROOM VENTILATION UNITS
Plug & Play engine room systems can handle up to four fans serving engine room
ventilation.

Each fan is powered by eco-friendly, energy-saving and high-efficiency EC motors,


making the P&P engine room ventilation system the most advanced and efficient
system to maintain internal engine room conditions.

Available electrical standards: Key features


• 3x400V - 50/60Hz • Highly efficient
• 3x460V - 50/60Hz • Sturdy marine execution
• Speed control
• PAG impellers
• Compact design
The Heinen & Hopman Plug & Play Engine Room Ventilation Systems are
equipped with the most recent technologies available on the market for
Marine HVAC systems.

Highly efficient EC motor driven axial fans and the latest aerodynamic
PAG impellers reduce the overall power consumption of the engine room
ventilation system.

Each fan has a glossy epoxy coating, available in a wide variety of colors
and combinations. Quick connectors and multi-cables are supplied with
the unit and control panel, making on-board electrical connection simple
and direct. The compact design allows the unit to be installed directly
with bolts and nuts fixed to the ship’s foundation.
Image: Engine room ventilation control
Available configurations
• One axial supply fan and natural exhaust
• Two axial supply fans and natural exhaust
• One axial supply fan and one exhaust fan
• Two axial supply fans and two extract fans
• Two supply fans and two extract fans
• Up to N.4 fire damper control and power supply
• Modbus network interface
• General alarm contact
• Remote start/stop and capacitance reduction contacts
Case material Steel
Internal case finishing Special epoxy painted RAL9010
External case finishing Special epoxy painted RAL9010
Connections Flanged on both sides
Blades orientation Static
Factory balancing Dynamic
Impeller material Reinforced glass nylon (PAG)
Fan motor High efficient EC fan
Motor protection IP54
Motor efficiency class IE4
Protection grid Upon request
Fan silencer Upon request

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
Refer to the appropriate chapter for information about the control set.

44
Technical specifications

Air flow Static pressure Inner ø Outer ø RPM Absorbed power


MODEL
(m3/h) (Pa) (mm) (mm) (kW)

5.000 251 452 525 2015 0,605


AD452
10.000 253 452 525 2925 1,63
15.000 351 700 805 1640 2,72
AD700 20.000 355 700 805 1800 3,76
25.000 352 700 805 2000 5,19

NOTES:
Other cusomized executions are available upon request.
Where possible, H&H suggests installing a sound damper above the fan.

Image: Standard model AD452

Image: Standard model AD700

45
ENGINE ROOM VENTILATION UNITS - CONTROL SET
Plug & Play controls are designed to be easy to use, easy to install and flexible for the
most cramped onboard configurations.

Engine room ventilation switchboards can control up to four independent fans and
four fire dampers.

Available electrical standards: Key features


• 3x400V - 50/60Hz • Quick cabling
• 3x460V - 50/60 Hz • Easy installatoin
• 7” touch screen
• PLC control logic
• Remote control
The engine room ventilation is controlled and monitored by our specially
designed P&P switchboards, made according to the number of fans
to be controlled. All switchboards come with pre-installed multi-pole
connectors. This gives the possibility to quickly and easily proceed with
the installation, just connect the multi cables.

Chiller control systems are PLC type. An optional 7” touchscreen can be


installed on the switchboard.

The PLC controller offers the ultimate in control technologies such as:
• Hour counter (with auto-advise for maintenance)
• Automatic pressure control
• Automatic temperature control
• Automatic emergency shutdown Image: Engine room ventilation control
• N. 4 Fire damper control
• Temperature indicator
• Pressure indicator
• AUTO/MANUAL switch
• Alarm controller
• Remotelu turned off
• General alarm contact
• Modern and smartly designed graphical interface
• Internet LAN connection for remote monitoring and control

Each control of the cooling module is centralized on the corresponding switchboard. The control of each unit can be
made from five different control stations:
• Locally via plug-in service tool (standard)
• Locally via touchscreen (optional)
• Via web browser from the on-board internet network (optional)
• Via web browser via the internet (optional)
• By smartphone or tablet via the P&P mobile app (optional)
Material Shining painted iron
Touch screen 7” Siemens
Soft starter Contained inside the panels
Installation Mounting brackets
Electrical connections Multi-cable for chiller modules
Standard painting RAL9010
PLC Siemens Climatix
Aux connection sockets KNX network, Internet LAN, ST LAN
Casing IP class IP54
Multiple connectors IP IP68

NOTES:
For more technical information, log in to https://doc.plugandplayhvac.com
All dimensions are ± 5mm.
46
Technical specifications

Electrical Control H W L Fan


MODEL
standard interface (mm) (mm) (mm) control

3x400V/50Hz
ENG. ROM. V. 7”touch 505 200 405 EC
3x460V/60Hz

Image: Engine room ventilation control switchboard

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our products. We are eager to
explain the possibilities for your vessel or structure.

Scan the QR-code or visit heinenhopman.com


47
Heinen & Hopman
encourages a more
sustainable world. By
providing eco-friendly
solutions and services
we offer our clients
the option of reducing “ Do you require more information
about our products or do you
energy consumption “
require advice? I am keen to
and thus CO2
emissions.
help you further!

Huib Wassink
- Sales Manager
sales@heinenhopman.com

OUTSIDE HUMIDITY
35°C 90%
45°C 40%

22º C Inside
PROVIDED BY
HEINEN & HOPMAN
www.heinenhopman.com
48
Heating Ventilation Air Conditioning Refrigeration

You might also like