S-1 S-2 S-3 S-4 S-5

1F-ACU 1F-ACU 1F-ACU 1F-ACU 1F-ACU

W-3 W-2 W-2 W-2 W-2 W-4 W-4


COMPUTED COOLING LOAD RATED
D-6 A R E A C O D E DESTINATION CAPACITY T Y P E
CHANGING
ROOM
D-6 D-6
HP
D-6
GENERAL MANAGER'S OFFICE SHOP SHOP
D-5 ASSISTANT MANAGER'S OFFICE CR FOR CR FOR
EMPLOYEE'S MEN WOMEN
D-6 F I R S T F L O O R RECEPTION BEDROOM-1 CENTRAL TYPE
LOUNGE

D-6
EMPLOYEE'S F I R S T F L O O R SPLIT TYPE
STUFF D-4 D-4 D-2 D-2

D-4 F I R S T F L O O R EMPLOYEE'S LOUNGE SPLIT TYPE


D-4

GENERAL
RECEPTION F I R S T F L O O R SPLIT TYPE
MANAGER'S OFFICE
C-1
ASSISTANT
1F-ACU
F I R S T F L O O R SPLIT TYPE
MANAGER'S OFFICE

F I R S T F L O O R SHOP SPLIT TYPE


DN

L O B B Y

ELEVATOR E S C A L A T O R ELEVATOR F I R S T F L O O R SHOP SPLIT TYPE

UP
UP
F I R S T F L O O R DINING ROOM MULTI-SPLIT TYPE
1 2 3 4 5 6 7 8 9 111213141516171819202122

F I R S T F L O O R COFFEE LOUNGE AREA MULTI-SPLIT TYPE


MS-1 MS-2
FIRE FIRE
D-4

D-4
1F-ACU 1F-ACU
EXIT EXIT
F I R S T F L O O R

D-4
F I R S T F L O O R
D-4

F I R S T F L O O R
DINING ROOM D-2 D-2 COFFEE LOUNGE AREA ELECTRICAL ROOM
D-3 LOUNGE
STORAGE F I R S T F L O O R
KITCHEN
R O O M

F I R S T F L O O R

D-1 D-1

W-1 W-1
F I R S T F L O O R

E N T R A N C E
F I R S T F L O O R
PLANT
B O X
PLANT
F I R S T F L O O R
B O X
PLANT
B O X
PLANT
UP UP B O X

RAMP UP 5.00 5.00

1. COOLING LOAD CALCULATIONS ARE IN ACCORDANCE WITH THE PHILIPPINE MECHANICAL CODE, 2012 ED.

2. ALL WORKS SMALL SHALL BE EXECUTED IN CLOSE COORDINATION WITH THE WORKS OF THE TRADES, COORDINATE WITH THE ARCHITECTURAL AND
ELECTRICAL THE EXACT LOCATION OF ALL AIR CONDITIONING UNITS AND PIPING.

3. PIPE ALL CONDESATED RAIN LINES IN THE NEAREST FLOOR/CATCH DRAIN, USE MINIMUM 25MM DIAMETER PVC PIPE DRAIN LINES.

4. AIR CONDITIONING UNIT SHOULD BE INSTALLED BY A QUALIFIED PROFESSIONAL TECHNICIAN.

5. THE INSTALLATION HOLD SHOULD BE STRONG ENOUGH TO SUPPORT THE AIR CONDITIONING UNIT, USE IRON SUPPORT THAT IS FIXED ON THE
BUILDING IF NECESSARY.

F I R S T SCALE
F L O O R 1:100
P L A N MTRS.
6. AIR CONDITIONING UNITS SHOULD AVOID DIRECT SUNLIGHT, INSTALL SUNSHADE BOARD, IF NECESSARY.

FROM THE SCHOOL OF: NOTE: CHECKED BY: PROJECT TITLE: APPROVED BY: SHEET CONTENTS: SHEET NO:

Drawings and specifications and other contract


BENGIE A. ANTONIO FIRST FLOOR PLAN
documents duly signed, stamped or sealed,as
M A R I A N O M A R C O S S T A T E U N I V E R S I T Y
A-1
instruments of service,are the intellectual property and P R O F E S S O R

C I V I L E N G I N E E R / A R C H I T E C T
COLLEGE OF INDUSTRIAL TECHNOLOGY
documents of the architects,whether the object for
which they are made is executed or not.It shall be
unlawful for any person to duplicate or to make copies DRAWN BY: PROPOSED 4 STOREY HOTEL
P . G O M E Z S T R E E T L A O A G C I T Y of said documents for use in the repetition of and for
REG:
PTR:
TIN:
ISSD ON:
C A D T 1 1 0 - A R C H I T E C T U R A L I I - C O M M E R C I A L other projects or buildings, whether executed partly or
in a whole, without the written consent of architect or
WIELMER G. DUMRIQUE. M R . D U M B R I Q U E Z 1 1
author of said documents.
Art. iv-Sec. 33 RA9266 B S I T - C A D T 3 - A PROJECT LOCATION:BRGY. 5 STO. NINO NUEVA ERA ILOCOS NORTE O W N E R