You are on page 1of 1

"CM"

C2 C3
* STUDY PURPOSE ONLY
C1 C4 C5

MATERIAL GRADE M20 & Fe500


LAP LENGTH - M20
COLUMNS - 46XD
SLABS & BEAMS - 57XD

ROOF SLAB

STEEL AS PER SCHEDULE


T8@100 C/C
PLINTH BEAM PLINTH LVL.

GROUND BEAM GROUND LVL.


C6
FOUNDATION FOOTING LVL.

KEY SECTION
C7 C9 C10 NTS
C8
SCHEDULE ( ) LONG BARS
SHORT BARS

*NOTE: WE ARE ONLY RESPONSIBLE FOR SOUNDNESS OF STRUCTURE


* STRUCTURAL LAYOUT @ FOUNDATION LEVEL

150(Min.)
FIRST FLR. LVL. Ld REFLECTED THROUGH THE DRAWING ONLY & NOT FOR EXECUTION

D
THESE GENERAL NOTES APPLY TO ALL DRAWINGS. THE APPLY TO ALL RELEVANT PORTIONS
Ld 450 OF THE STRUCTURAL STANDARD PROVISIONS SPECIFIED HERE UNDER ALL WORKS &
SHALL FORM PART OF THIS CONTRACT.
GENERAL NOTES :-

150
LINKS IN CONFINE
IN CONFINE ZONE
1) THIS DRAWING SHALL BE READ ALONG WITH ARCH DRAWING,THE CONTRACTOR SHALL VERIFY

ZONE:-T8-100C/C,
SPECIAL CONFINING REINFORCEMENT
ALL DIMENSIONS & LEVELS ON SITE & RESOLVE ALL DISCREPANCIES WITH ARCHITECT OR

TRANSVERSE REINFORCEMENT
ENGINEER PRIOR TO COMMENCEMENT OF WORK. DRAWING INDICATES GENERAL & TYPICAL
DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE OF SIMILAR CHARACTER TO DETAILS

h/3
SHOWN & ALTHOUGH NOT SPECIFICALLY INDICATED, SIMILAR DETAILS OF CONSTRUCTION
SHALL BE USED & SUBJECTED TO REVIEW BY THE ENGINEER.
2) MATERIAL GRADE M20 & Fe500 SHALL BE USED.(UNLESS SPECIFIED)
SCALE = NTS

AS PER 7-3-3
3) NOMINAL COVERS FOR MILD CONDITION

AS PER 7-4-1
I) FOOTINGS : 50 MM , III) SLABS : 20 MM , V) LIFT WALL/SHEAR WALL : 40 MM ,
A (SHORT SPAN)
II) COLUMNS : 40 MM , IV) BEAMS : 25 MM

ZONE:-T8-200C/C
4) IN CASE OF SLAB IF MAIN REINF, DIAMETER EXCEEDS 12MM THEN COVER FOR

LINKS IN REST
LD
MODERATE AND SEVERE EXPOSURE CONDITION SHOULD BE INCREASED BY 5MM.

IN REST PART
5) MAXIMUM ALLOWABLE HEIGHT OF COLUMN WITHOUT ANY BRACER OR TIE

h/3
1) 230 WIDE-4000MM. 2) 200 WIDE-3400MM. 3) 300 WIDE-5000MM.

6) LAP LENGTH - M20 M25 M30 M35 M40 &


ABOVE Note:-

hc 300MM.
COLUMNS
SLABS & BEAMS
46XD
57XD
40XD
50XD
37XD
46XD
32XD
40XD
29XD
36XD
} At any section of slab/beam not
more than 50% bars to be lapped

B (LONG SPAN)
& laps should be staggered.

h
PROVIDE A CROSSTIE
A A 7) NO SPLICES SHALL BE MADE AT POINTS OF MAXIMUM STRESS. E.G.,TOP BARS IN BEAMS
10D (75MM) & SLABS SHOULD BE SPLICED AT MID SPAN AND BOTTOM BARS AT SUPPORTS. SPLICES

IN CONFINE ZONE
SHALL BE STAGGERED WHEREVER POSSIBLE.
COLUMN MAIN BAR LAP
Bc 300 mm.

MINIMUM BENT
SHOULD BE @MIDDLE COLUMN
8) TOP BARS OF CANTILEVER BAR SHALL NOT HAVE ANY LAP.
6MM:75MM h/3 & STAGGERED
.

9) ALL STRUCTURAL CONCRETE SHOULD BE WEIGH BATCHED, MACHINE MIXED&MECHANICALLY


8MM:80MM

h/3
VIBRATED
10MM:100MM
10) FOR CANTILEVERS, TOP BARS TO BE ANCHORED BEHIND FOR-70XDIA. OF BARS OR SPAN
LINKS @ 1/2
OF CANTILEVERS (WHICHEVER IS GREATER)
SPACING FOR h/3
11) MOVEMENT CRACKS
hc 300 mm. PLINTH LVL. ALL VISIBLE CRACKS IN NEWLY CAST CONCRETE SHALL BE SEALED BY PRESSURE GROUTING
BEFORE APPLICATION OF FINISHES.
h SHALL BE LARGER OF
DESIGN FOR :- ( G+0 )
hc AND Bc
*LOADS *REFERENCE
TYPICAL DETAIL OF 150
DETAIL FOR TRANSVERSE BEARING CAPACITY KN/SQMT IS 456-2000 R.C.C.

MINIMUM BENT FOR LINKS REINFORCEMENT IN COLUMN TYPICAL C/S OF COLUMN *DETAIL OF PLAN FOR BOX FOOTING LIVE LOAD 2.00 KN/SQMT IS 13920-2016 Ductile Detailing

SCALE = NTS SCALE = NTS SCALE = NTS SCALE = NTS FLOOR FINISH 1.00 KN/SQMT IS 800-2007 Steel structures
BRICK DENSITY IS 3370-2009 Liquid retaining structure
BURNT BRICK 18.00 KN/CUB.MT
Criteria for earthquake
LOW WEIGHT BRICK 06.00 KN/CUB.MT IS 1893-2016
resistance design

STATUS OF RELEASE
FOR APPROVAL
FOR DISCUSSION
FOR TENDER
FOR CONSTRUCTION ARCHITECT DRAWING DATED 01-07-2019
COLUMN & FOOTING SCHEDULE :- ( LINKS IN CONFINE ZONE :- T8 - 100 C/C )
REVISIONS - DRAG. BY DSG. BY APR. BY DATE
1
GROUND SIZE
M20:Fe500 M20:Fe500

300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 DETAIL OF LINKS ARRANGEMENTS 2
TO STEEL 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12
FOR COMBINED STEEL 3
ROOF LINKS T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C
4
BASE SIZE 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300 300 X 300
DRAWING TITLE :- BY DATE
TO STEEL 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12 8-T12
BALU S. 1-Jul-19
DRAG.
GROUND LINKS T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C T8@100 C/C STRUCTURAL DETAILS DSG. BAHUBALI 1-Jul-19

300
SHORT DIR T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C + OF FOUNDATION LEVEL. QC. AJIT T. 1-Jul-19
APPR. B.P.B. 1-Jul-19
M20:Fe500

LONG DIR T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C T10@150 C/C
PROJECT :-
FOOTING
D/d 300 300 350 300 300 300 300 350 300 300 300 PROPOSED CONSTRUCTION OF SANITARY COMPLEX AT TRIBAL SCHOOL

SIZE 1100 x 1100 1400 x 1400 1500 x 1500 1300 x 1300 1200 x 1200 1100 x 1100 1400 x 1400 1500 x 1500 1300 x 1300 1200 x 1200 8-T12 CLIENT :-
DWG NO. SHEET NO.
M15

P.C.C 150 THK 1400 x 1400 1700 x 1700 1800 x 1800 1600 x 1600 1500 x 1500 1400 x 1400 1700 x 1700 1800 x 1800 1600 x 1600 1500 x 1500 P.W.D.

REMARK Box Footing Box Footing Box Footing Box Footing Box Footing Box Footing Box Footing Box Footing Box Footing Box Footing ARCHITECT :- 2019/300 ST- 01
P.W.D. -1-
COLUMN MARKED C1 C2 C3 C4 C5 C6 C7 C8 C9 C10
DELTACOM STRUCTURAL
COUNTING 1 1 1 1 1 1 1 1 1 1
CONSULTANTS
TOTAL NUMBERS TOTAL :- 10
NASHIK OFFICE PUNE OFFICE
" Avdhoot Adhar ", 2nd floor'
Opp. Hotel Vihar, Old Gangapur Naka, Dange Chowk, Thergaon,
Nasik - 422005 Pune - 411033
Tel - 0253-2314995, 2571096 Tel - 83800 21794
Email - design@deltacomcpl.com Email - design.pune@deltacomcpl.com

"Inch"
deltacomscpl@gmail.com dscplpune@gmail.com
Website - www.deltacomcpl.com