EEG-1200K: Electrocephalograph Product Features & Technical Data
EEG-1200K: Electrocephalograph Product Features & Technical Data
EEG-1200K Electrocephalograph
Product Features & Technical Data
PRODUCT FEATURES
General
The EEG-1200 Electroencephalograph is designed for both clinical and research use.
(For details of the composition in regards of standard and optional equipment please see technical data section)
2
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Acquistion
3
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Data review during acquisition
Comparison mode: The EEG Scope function lets you look back into
and review previous epochs of EEG while simultaneously monitoring
current EEG acquisition. One side of a split screen shows previous EEG
epochs and the other side shows the current EEG.
Review
Easy to use software interface
EEG-1200 software has an easy to operate graphical user interface
which can be adapted to user requirements. Standard settings provide
an intuitive software layout making it easy to learn even for beginners.
Individual configuration of the software layout allows adapting EEG-
1200 to every need:
flexible arrangement of menu bars
colouring of waveforms
individual montage settings
4
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
3D voltage mapping
Whole head maps provide a complete overview and a better interpretation
of the topography of EEG abnormalities. Just click on a detected pattern to
obtain 3D maps of the whole head. Click on a particular view to obtain a
series of maps showing the change over time.
EEG mapping
The EEG mapping module QP-220AK provides amplitude and frequency
mapping of EEG waveforms
Real-time mapping during acquisition
Off-line mapping during review for selected intervals
Up to eight frequency maps (seven power/voltage maps at seven different frequency bands and one map of all
frequency bands)
Power/Voltage spectra for up to 32 channels of EEG waveform data
Edge frequency, average frequency, median frequency or peak frequency for each spectrum is indicated with a
mark.
Reporting
NeuroReport is the common reporting tool for all
neurological systems from Nihon Kohden. Various predefined
templates can be used to create customized reports for
different examination types, physicians or other criteria.
You can also create an EMU examination report which has
screen comments automatically assigned to seizure events.
A powerful auto-text function helps to create individual
reports. Saved within the database in a license free format,
the reports will be automatically converted into PDF after
finalizing.
5
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Digital video system (option)
Patient image including sound can be recorded and reviewed
synchronized with the EEG waveform.
A wide range of different video formats (MPEG1 and MPEG4)
and resolutions (up to 720*576 pixel) are available.
Real time and fast forward mode (up to 20 times) for reviewing
the video
Comfortable clipping and snapshot functions allow reducing
the video data by creating new video EEG clips or attaching
the clipped video file to the original EEG recording.
6
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Data integration and management
Polaris.one
Polaris.one allows you to easily manage EEG data and examination schedules.
SQL based database for EEG, EMG/EP, and ECG data
User interface can be scaled according to user needs
Calendar view and to-do lists
Copies of EEG data can be stored for personal or global use
Presentation functionality for case conferences
Auto-proposing for text input fields
Manual, semi-automatic, and automatic transfer and archive as background service
Integrated NeuroReport incl. PDF conversion
Offline functionality for acquisition and review stations
Multi-client-capability with user-related filtering of patients
Extensive user rights management (via groups)
Activity log records all changes to medical data
Integrated DVD/CD burning
EEG PortaView
EEG PortaView integrates review software into EEG data files and saves them on a portable storage device, so you
can review the EEG data on any Windows PC without special software. Just carry the EEG data and you can review
anytime and anywhere.
7
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
TECHNICAL DATA
DATA ACQUISITION
8
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
JE-910A/AG electrode junction box
9
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Maximum number of recorded
referential electrodes and sampling 256 (2 kHz), 128 (5 kHz), 64 (10 kHz)
frequency (clinical line)
Maximum number of recorded
referential electrodes and sampling 256 (10 kHz)
frequency (extended line for research)
Input range: ±3.2mV or ±12,8mV (selectable)
Input impedance: 200 MΩ
Internal noise level: Less than 1.5 μVp-p (0.53 to 120 Hz)
CMRR: 110 dB or greater (60 Hz) (EEG inout)
Time constant: 2 or 10 s, selectable
High-cut filter: 3000 Hz (− 18 dB/oct), depending on the sampling frequency
Offset tolerance: ±1000 mV
A/D conversion: 24 bits
Sampling and hold: All electrodes at the same time
Sampling frequency: 10000 Hz (max)
JE-208A 25 33 8 (4ch) 1
JE-213A / JE-214A 64 1
JE-215A / JE-226A /
64 1
JE-227A / JE-228A
JE-921A/AG 25 14 (7ch) * 3 (X5, X6, X7) 1 6 **
JE-910A/AG 25 4 3
DATA PROCESSING
Sensitivity
OFF, 1, 2, 3 (2.5), 5, 7, 10, 15, 20, 30, 50, 75, 100, 150,
EEG INPUT:
200 μ V/mm
DC INPUT: OFF, 10, 15, 20, 30, 50, 75, 100, 150, 200 mV/mm
0.001, 0.003, 0.03, 0.1, 0.3, 0.6, 1.0, 2.0, 5.0, 10.0 s
Time constant (Low-cut filter): 0.016, 0.03, 0.08, 0.16, 0.27, 0.53, 1.6, 5.3, 53, 159 Hz
(− 6 dB/oct)
10
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
JE-921A electrode junction box
15, 30, 35, 60, 70, 120 (− 12 dB/oct), 50 (RAPID), 300 Hz (− 18 d
B/oct)
High-cut filter:
JE-120A electrode junction box (option)
15, 30, 35, 60, 70, 120, 300, 600, 1200 (− 12 dB/oct),
50 (RAPID), 3000 Hz (− 18 dB/oct)
AC filter: 50 or 60 Hz, (rejection ratio: 1/25 or more)
Calibration waveform
Waveform shape: 0.25 Hz step wave or 10 Hz sine wave
Voltage: 2, 5, 10, 20, 50, 100, 200, 500, 1000 μV (×1000 for DC input
signal)
ECG elimination filter: Available in acquisition and review programs
Impedance check
Indication on the screen: All electrodes are displayed on the screen in electrode position
layout. Impedance for each electrode is displayed and
electrodes with impedance higher than the preset impedance
threshold are highlighted.
Indication on LED: LEDs on the electrode junction box with impedance higher than
the preset impedance threshold light.
Impedance threshold: 2, 5, 10, 20 and 50 kΩ
Pattern: 36 sets of programmable montages combined with
programmable individual amplifier settings
Reference electrode selector: A1 A2, A1 A2, A1 A2, A1 + A2, VX, AV (with
unsuitable electrode deletion function), Aav, Org, SD, BN and
OFF
Marking signal: Photic stimulation mark, Hyperventilation mark
DISPLAY
11
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Waveform freeze: Provided
Available when the optional QI-120A Camera Capture Unit and
Patient image display:
video camera are used.
Waveform sweep speed: 0.1, 0.2, 0.5, 1, 2, 5, 10, 15, 20, 30, 60 s or 5 min/page
Timing mark: 0.1, 1 s
Time scale: off, 0.2, 1 s
Event mark: Displays at the bottom of the screen
EEG scale: Provided
Dual display: Available
ACQUISITION PROGRAM
PHOTIC SIMULATOR
12
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
DIGITAL VIDEO UNITS (OPTOIN)
13
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
REVIEW PROGRAM
ELECTROMAGNETIC COMPATIBLITY
POWER REQUIREMENTS
SAFETY
CAN/CSA C22.2
Safety standard IEC 60601-1: 1988
No.601.1B-90
CAN/CSA C22.2
IEC 60601-1
No.60601-1-1-02
Amendment 1: 1991
(R2002)
IEC 60601-1 CAN/CSA C22.2
Amendment 2: 1995 No.60601-2-26-04
EN 60601-1
IEC 60601-1-2: 2001
Amendment 1: 1993
IEC 60601-1-2 EN 60601-1
Amendment 1: 2004 Amendment 2: 1995
14
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
EN 60601-1
IEC 60601-2-26: 2002
Amendment 13: 1996
CAN/CSA C22.2
EN 60601-1 -1: 2001
No.601.1-M90: 1990
CAN/CSA C22.2
EN 60601-2-26:2003
No.601.1-1S1-94
Type of protection against electric
Class I
shock:
Degree of protection against electric
shock (JE-921A)
Electrode jacks, bipolar jacks, SpO2 connector, CO2 connector
Type BF applied part:
JE-921A, electrode junction box: 185 (W) × 72 (D) × 167 (H) mm, 1.0 kg
200 (W) × 300 (D) × 185 (H) mm, 6.5 kg
PC unit: The dimensions and weight differ according to model.
Refer to the Operator’s manual of the PC unit.
SM-120AK, isolation unit: 181 (W) × 320 (D) × 140 (H) mm, 13 kg
LS-120A/AG, photic stimulator
155 (W) × 300 (D) × 75 (H) mm, 4.10 kg
control unit:
QD-120A, analog output unit: 155 (W) × 300 (D) × 75 (H) mm, 2.32 kg
NF-KD1200/1, cart: 565 (W) × 625 (D) × 830 (H) mm, 44 kg
15
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
OPERATION CONDITIONS
ELECTROMAGNETIC EMISSIONS
The EEG-1200’s essential performances in EMC standard satisfy the following criteria.
EEG-1200 is intended for use in the electromagnetic environment specified below.
The customer or the user of the EEG-1200 should assure that it is used in such an environment.
* When the optional JE-207A/209A/212A electrode junction box is used, the compliance for RF emission is class A.
The EEG-1200 with JE-207A/209A/212A is suitable for use in all establishments excluding domestic establishments
and those directly connected to the public low-voltage power supply network that supplies buildings used for
domestic urposes.
16
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Electromagnetic Immunity
The EEG-1200’s essential performances in EMC standard satisfy the following criteria. This Model EEG-1200 is
intended for use in the electromagnetic environment specified below. The customer or the user of the EEG-1200
should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment -
guidance
Electrostatic ±6 kV contact ±6 kV contact Floors should be wood, concrete
discharge (ESD) ±8 kV air ±8 kV air or ceramic tile. If floors are
IEC 61000-4-2 covered with synthetic material,
the relative humidity should be
at least 30%.
Electrical fast ±2 kV for power supply ±2 kV for power supply Mains power quality should be
transient / burst lines lines thatof a typical commercial or
IEC 61000-4-4 ±1 kV for input/output ±1 kV for input/output hospital environment.
lines lines
Surge ±1 kV differential mode ±1 kV differential mode Mains power quality should be
IEC 61000-4-5 ±2 kV common mode ±2 kV common mode that of a typical commercial or
hospital environment.
Voltage dips, short <5% UT (>95% dip in UT) <5% UT (>95% dip in UT) Mains power quality should be
interruptions and for 0.5 cycle for 0.5 cycle thatof a typical commercial or
voltage variations on 40% UT (60% dip in UT) 40% UT (60% dip in UT) hospital environment.
power supply input for 5 cycles for 1 cycle If the user of the EEG-1200
lines 70% UT (30% dip in UT) 70% UT (30% dip in UT) requires continued operation
IEC 61000-4-11 for 25 cycles for 2 cycles during power mains
<5% UT (>95% dip in UT) (for 1 cycle*1) interruptions, it is recommended
for 5 s <5% UT (>95% dip in UT) that the EEG-1200 be powered
for 5 s from an uninterruptible power
supply or a battery.*2
Power frequency 3 A/m 3 A/m Power frequency magnetic fields
(50/60 Hz) should be at levels characteristic
magnetic field of a typical location in a typical
IEC 61000-4-8 commercial or hospital
environment.
NOTE: UT is the AC mains voltage prior to application of the test level
*1 When the QI-120A is connected to the EEG-1200.
*2 It is recommended that the EEG-1200 be powered from an uninterruptible power supply or a battery if the power
quality is not stable.
17
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Immunity test IEC 60601 test Compliance Electromagnetic environment – guidance
level level
3 Vrms Portable and mobile RF communications
3 V/m equipment should be used no closer to any part
of the EEG-1200, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency of
Conducted RF 3 Vrms the transmitter.
IEC 61000-4-6 150 kHz to 80
MHz Recommended separation distance
Radiated RF d = 1.2 P
IEC 61000-4-3 3 V/m
80 MHz to 2.5 d = 1.2 P 80 MHz to 800 MHz
GHz d = 2.3 P 800 MHz to 2.5 GHz
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
*1 Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones
and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured field strength in the location in which
the EEG-1200 is used exceeds the applicable RF compliance level above, the EEG-1200 should be observed
to verify normal operation. If abnormal performance is observed, additional measures may be necessary,
such as re-orienting or relocating the EEG-1200.
*2 Over the frequency range 150 kHz to 80 MHz, field strengths should be less than for all other
functions.
18
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Avoiding Electromagnetic Interference (Impedance Respiration)
Impedance respiration measurement is very sensitive and affected by electromagnetic interference. Technological
limitations do not allow immunity levels higher than 1 Vrms for conducted disturbances induced by RF fields.
Electromagnetic fields with conducted disturbances above 1 Vrms may cause measurement error. Do not use
electrically radiating equipment near the impedance respiration measurements.
When the JE-921A electrode junction box is connected to the EEG-1200 electroencephalograph
NOTE 1: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection structures, objects and people.
NOTE 2: It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to
assure that they meet the minimum specification.
* Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength outside the shielded location in which the JE-921A that is connected to the
EEG-1200 is used exceeds 3 V/m, observe the JE-921A that is connected to the EEG-1200 to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as relocating the JE-921A that is
connected to the EEG-1200 or using the shielded location with a higher RF shielding effectiveness and filter attenuation.
NOTE
The JE-921A that is connected to the EEG-1200 should be used in a shielded location with an RF filter
attenuation of 31 dB over the frequency range 80 MHz to 2.5 GHz. If the JE-921A that is connected to the
EEG‑1200 is used outside shielded location, use it in a location where the measured field strength is less than
0.3 V/m. To measure shielding effectiveness, consult a service engineer.
19
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
Recommended Separation Distances between Portable and Mobile RF Communications Equipment
The EEG-1200 is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the EEG-1200 can help prevent electromagnetic interference by maintaining
a minimum distance between portable and mobile RF communications equipment (transmitters) and the EEG-1200
as recommended below, according to the maximum output power of the communications.
20
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
STANDARD COMPOSITION
For routine study:
For 64 channel monitoring: For 128 channel monitoring: For 192 channel monitoring:
Main unit, EEG-1200K, PC unit, Main unit, EEG-1200K, PC unit, Main unit, EEG-1200K, PC unit,
Electrode junction box, JE-207A Electrode junction box, JE-209A Electrode junction box, JE-212A
Input box converter, QI-122AJ/K Input box converter, QI-122AJ/K Input box converter, QI-122AJ/K
STANDARD ACCESSORIES
OPTIONAL SOFTWARE
21
Neurofax EEG-1200K | Product Features / Technical Data (Ver. 120131)
This brochure may be revised or replaced by Nihon Kohden at any time without notice.