You are on page 1of 4

cEEG Monitoring

Maximum flexibility
without compromise
Superior Amplifier Solutions
Nihon Kohden amplifiers have long been
regarded for delivering superior signal quality
JE-921 Multimodalilty The use of continuous EEG (cEEG) can
using the highest recording specifications 10-20 System Amplifier enhance the neurological assessment and
available. Our flagship JE-921 provides
flexibility and configurability that is exclusive Specifications care of critically ill patients through
in the industry. With a full 10-20 electrode
Number of Inputs:
array, 14 bipolar inputs, built in End Tidal 32 Channels Total early detection of reversible neurological
CO2 and SpO2, this proven technology will 10-20 Input Layout
increase ease of use and recording power 3 Dedicated Bipolar Channels
4 Programmable Bipolar Channels
deterioration.
for all types of EEG recordings.
4 DC Channels
When reliable trend data is instrumental Optically Isolated

in detecting subtle changes over time, you Input Impedance: Nihon Kohden amplifiers’ superior signal
can rely on the superior signal processing 100 MΩ

that has defined Nihon Kohden amplifiers CMRR: quality ensure reliable cEEG trends.
for decades, even in adverse recording > 105 dB
environments. Internal Noise Level: The QP-160 application is designed to fully
<3uV p-p (0.53-120Hz)

High-Cut Filter: integrate the EEG-1200 data with user-


300 Hz (-18 dB/oct)

Low-Cut Filter:
selectable trends over time. Areas of
clinical interest are easily recognized at
0.016-160 Hz

Sampling Frequency:
Up to 1000 Hz
the bedside and provide clinicians
fast review capabilities of the associated
EEG data over days, and even weeks, in a
single display with synchronized audio
and video data.
Superior Amplifier Solutions Data Capture and Analysis Vital Sign Integration
Nihon Kohden amplifiers have long been
regarded for delivering superior signal quality
JE-921 Multimodalilty The QP-160 application offers quantitative
EEG and real-time trend displays to quickly
Vital sign integration through the Neurofax
DC input or optional bedside monitor
using the highest recording specifications 10-20 System Amplifier identify changes over time. Color coded interface allows for time synchronized EEG,
available. Our flagship JE-921 provides annotations, as well as integrated event logs, vital sign numerics and QP-160 trending.
flexibility and configurability that is exclusive Specifications facilitate the review process. View real-time This real-time correlation between EEG and
in the industry. With a full 10-20 electrode EEG and a variety of single or dual time physiological parameters such as HR, SpO2,
Number of Inputs:
array, 14 bipolar inputs, built in End Tidal 32 Channels Total base trend displays for short- and long- term MAP and ICP assists in monitor-guided
CO2 and SpO2, this proven technology will 10-20 Input Layout trend comparison either at the bedside decision support.
increase ease of use and recording power 3 Dedicated Bipolar Channels or remotely. The integration of the vital sign data is
4 Programmable Bipolar Channels
for all types of EEG recordings. available at the bedside, as well as remotely
4 DC Channels These user-selectable trends allow review
When reliable trend data is instrumental Optically Isolated of data for a patient’s entire recording of for more timely EEG intervention by the
in detecting subtle changes over time, you Input Impedance: several days, even weeks in a single display. reviewing clinician.
can rely on the superior signal processing 100 MΩ Use integrated annotation and editing The QP-160 is flexible, yet comprehensive and
that has defined Nihon Kohden amplifiers CMRR: tools to navigate through the record. integrates cEEG and vital sign trends into
for decades, even in adverse recording > 105 dB Customize the layout of the EEG and trend • In spectral analysis, the EEG signals acquired Nihon Kohden’s trusted high quality EEG-1200
environments. Internal Noise Level: display on acquisition and review for by the EEG-1200 are analyzed with FFT for instrumentation.
<3uV p-p (0.53-120Hz) convenient navigation between trend and display of DSA, spectral edge, power and
Vital sign monitor integration is available for Nihon Kohden, GE, Philips
High-Cut Filter: EEG data. Optional synchronized digital power ratio measurements and Spacelabs monitors. See your Nihon Kohden representative for monitor
model and interface information.
300 Hz (-18 dB/oct) video enables confirmation of EEG traces • Asymmetry for DSA and FFT power trends
Low-Cut Filter: vs. environmental artifacts. Our unique can be displayed
0.016-160 Hz artifact detection algorithm marks the trends
• Amplitude integrated EEG (aEEG) is displayed
Sampling Frequency: influenced by electrode artifact for more

Configuration
Up to 1000 Hz
in a time compressed format and is inclusive
reliable interpretation.
within the QP-160 application
• Burst suppression parameters include burst
suppression ratio (BSR), inter burst interval (IBI),
and bursts per minute (BPM)
Flexibility
• Trend relationships between real time EEG
Sensitive to the space constraints in the busy ICU
changes and vital sign monitor data such
setting, Nihon Kohden offers a wide range of
as HR, SpO2 and EtCO2 along with other DC
configuration options from portable flexibility to
parameters for multimodality monitoring
dedicated bedside monitoring.
• Real-time numeric values are displayed with
• Fixed, fold-away wall-mount options
the trends
• Ceiling mount options
• Optional comprehensive EEG monitoring
pack (CPA) from Persyst ® includes RevealTM • Portable, compact cart-based systems for
Rosetta and MagicMarker ® multi-room and multi-purpose use
Different Thinking for
us.nihonkohden.com
Better Healthcare.™
NMLB 016 [C]-CO-0558 Different Thinking for Better Healthcare is a trademark of Nihon Kohden.
Persyst and MagicMarker are registered trademarks and Reveal is a
trademark of Persyst Corporation.

You might also like