Cat Electronic Technician 2019A v1.

0
Product Status Report

25/09/2021 20:58

Product Status Report


Parameter Value
Engine Serial Number XL600180
Equipment ID 350-1850-0013
Comments

G3500 Auxiliary Sensing (XL600180)


Parameter Value
Equipment ID 350-1850-0013
Engine Serial Number XL600180
ECM Serial Number 1152B028AL
Software Group Part Number 3227250-01
Software Group Release Date JUN08
Software Group Description G3500 ASM

Logged Diagnostic Codes [Diagnostic Clock = 10142:40:11 hours] - G3500 Auxiliary Sensing
(XL600180)
Code Description Occ. First Last
1719- 3 Generator Output Power Sensor : Voltage Above 6 10129:14:3 10131:42:0
Normal 2 0

Logged Event Codes [Diagnostic Clock = 10142:40:11 hours] - G3500 Auxiliary Sensing
(XL600180)
Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - G3500 Auxiliary Sensing (XL600180)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - G3500 Auxiliary Sensing (XL600180)


Code Description
No Active
Event Codes

Current Totals - G3500 Auxiliary Sensing (XL600180)


Description Value Unit
Total Operating Hours 10143 hours
Configuration - G3500 Auxiliary Sensing (XL600180)
Description Value Unit
Equipment ID 350-1850-0013
Engine Serial Number XL600180
Generator Output Power Sensor Scale 370.650 kW/V
Factor
Generator Output Power Sensor Offset 5.80 kW
Customer Password #1 ****************
Customer Password #2 ****************
Total Tattletale 87

Graphical Display G3500 EPG-Standard


Parameter Value
ECM Serial Number 0182B054HX
Software Group Part Number 3521125V03
Software Group Release Date FEB10
Software Group Description Advisor G3516B DTO

Logged Diagnostic Codes [Diagnostic Clock = 0] - Graphical Display G3500 EPG-Standard


Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [Diagnostic Clock = 0] - Graphical Display G3500 EPG-Standard


Code Description Occ. First Last
No Logged
Event Codes

Active Diagnostic Codes - Graphical Display G3500 EPG-Standard


Code Description
No Active
Diagnostic
Codes

G3516 EPG-Standard (XL600180)


Parameter Value
Equipment ID 350-1850-0013
Engine Serial Number XL600180
ECM Serial Number 1072B029AL
Personality Module Part Number 5389605-00
Personality Module Release Date APR17
Personality Module Description G3516C 1500 IM
Number of Engine Cylinders 16

Logged Diagnostic Codes [Diagnostic Clock = 10142:40:11 hours] - G3516 EPG-Standard


(XL600180)
Code Description Occ. First Last
1042- 9 ITSM : Abnormal Update Rate 4 10053:20:5 10142:30:4
5 3
1440- 9 Throttle Actuator : Abnormal Update Rate 3 10132:29:1 10132:29:1
7 7
1720- 9 Turbocharger Compressor Bypass Valve Actuator 3 10132:29:1 10132:29:1
: Abnormal Update Rate 7 7
109- 3 Engine Coolant Outlet Pressure Sensor : Voltage 2 10131:29:4 10131:29:4
Above Normal 7 7
254- 9 Electronic Control Module : Abnormal Update Rate 2 10131:29:4 10131:29:4
7 7
336- 2 Engine Control Switch : Erratic, Intermittent, or 2 10131:29:4 10131:29:4
Incorrect 7 7
444- 5 Starter Motor Relay : Current Below Normal 3 10131:29:4 10131:29:4
7 7
1440-11 Throttle Actuator invalid 7 10045:01:4 10131:29:4
9 7
524- 4 Desired Engine Speed Sensor : Voltage Below 2 10042:05:1 10042:05:1
Normal 2 2

Logged Event Codes [Diagnostic Clock = 10142:40:11 hours] - G3516 EPG-Standard (XL600180)
Code Description Occ. First Last
E198 (1) Low Fuel Pressure 6 10044:06:3 10107:21:5
0 5
E223 (1) High Gas Temperature 1 10135:34:3 10135:34:3
9 9
E225 (3) Engine Overcrank 2 10052:36:0 10052:36:0
7 7
E264 (3) Emergency Stop Activated 17 10047:26:1 10131:29:4
3 7
E269 (3) Customer Shutdown Requested 1 10131:29:4 10131:29:4
7 7
E864 (1) Low Gas Fuel Differential Pressure 6 10044:06:3 10107:21:5
0 5

Active Diagnostic Codes - G3516 EPG-Standard (XL600180)


Code Description
No Active
Diagnostic
Codes

Active Event Codes - G3516 EPG-Standard (XL600180)


Code Description
No Active
Event Codes

Current Totals - G3516 EPG-Standard (XL600180)


Description Value Unit
Total Operating Hours 10143 hours

Configuration - G3516 EPG-Standard (XL600180)


Description Value Unit
Equipment ID 350-1850-0013
Engine Serial Number XL600180
First Desired Timing 26.0 Deg
Second Desired Timing 26.0 Deg
Fuel Quality Input Type Configuration Unavailable
Fuel Quality 1000.00 Btu
Fuel Quality Sensor LHV Lower Setpoint Unavailable Btu
Fuel Quality Sensor LHV Upper Setpoint Unavailable Btu
Gas Specific Gravity 0.685
Fuel Specific Heat Ratio 1.400
Desired Emissions Gain Adjustment 98.00 %
Percentage
Air/Fuel Proportional Gain 0
Air/Fuel Integral Gain 0
Low Idle Speed 1200 rpm
Minimum Engine High Idle Speed 1745.0 rpm
Maximum Engine High Idle Speed 2000.0 rpm
Engine Acceleration Rate 45 rpm/s
Desired Speed Input Configuration 4-20 mA Input
Governor Type Setting Droop
Engine Speed Droop 0.0 %
Governor Gain Factor 0
Governor Stability Factor 2
Governor Compensation Factor 0
Auxiliary Proportional Governor Gain 1 0
Auxiliary Integral Governor Gain 1 0
Auxiliary Derivative Governor Gain 1 0
Driven Equipment Delay Time 120.0 sec
Crank Terminate RPM 350 rpm
Engine Purge Cycle Time 0 sec
Cooldown Duration 0 min
Cycle Crank Time 15 sec
Engine Overcrank Time 120 sec
Engine Speed Drop Time 30.0 sec
Engine Pre-Lube Time Out Period 120.000 sec
High Inlet Air Temperature Engine Load 80 %
Set Point
Impending Shutdown Delay Enable Status Disabled
Impending Shutdown Delay Time 10.0 min
Engine Output Power 1978 hp
Engine Driven Accessory Load 48 hp
Configuration
Customer Password #1 ****************
Customer Password #2 ****************
Total Tattletale 397

Monitoring System - G3516 EPG-Standard (XL600180)


Description State Trip Point Delay Time
Engine Overspeed
Most Severe (3) Always On 2175 rpm 0 sec
High Eng Oil to Eng
Coolant Differential
Temp
Least Severe (1) Always On 25 Deg F 20 sec
Moderate Severity (2) On 25 Deg F 20 sec
Most Severe (3) Always On 36 Deg F 20 sec
High Engine Coolant
Temperature
Least Severe (1) On 228 Deg F 20 sec
Moderate Severity (2) Off 234 Deg F 20 sec
Most Severe (3) Always On 239 Deg F 20 sec
High Engine Oil
Temperature
Least Severe (1) Always On 219 Deg F 20 sec
Moderate Severity (2) Off 228 Deg F 20 sec
Most Severe (3) Always On 234 Deg F 20 sec
High Fuel Pressure
Least Severe (1) On 19.6 psi 10 sec
High Fuel Temperature
Least Severe (1) On 140.0 Deg F 20 sec
High Gas Fuel
Differential Pressure
Least Severe (1) On 5.1 psi 10 sec
High Inlet Air
Temperature at High
Engine Load
Least Severe (1) On 185.0 Deg F 30 sec
Moderate Severity (2) Off 212.0 Deg F 20 sec
Most Severe (3) Always On 194.0 Deg F 60 sec
High Inlet Air
Temperature at Low
Engine Load
Least Severe (1) On 185.0 Deg F 30 sec
Moderate Severity (2) Off 212.0 Deg F 20 sec
Most Severe (3) Always On 194.0 Deg F 60 sec
High Oil Filter
Differential Pressure
Least Severe (1) Always On 15 psi 10 sec
Moderate Severity (2) On 19 psi 10 sec
Most Severe (3) Always On 20 psi 10 sec
High System Voltage
Least Severe (1) On 34.0 Volts 20 sec
Low Engine Coolant
Temperature
Least Severe (1) On 41 Deg F 20 sec
Low Fuel Pressure
Least Severe (1) On 15 psi 10 sec
Low Gas Fuel
Differential Pressure
Least Severe (1) On 0.7 psi 10 sec
Low Oil Filter
Differential Pressure
Least Severe (1) Always On 1 psi 10 sec
Moderate Severity (2) On 1 psi 10 sec
Most Severe (3) Always On 1 psi 10 sec
Low System Voltage
Least Severe (1) On 20 Volts 20 sec
Moderate Severity (2) On 19 Volts 20 sec
Most Severe (3) Always On 18 Volts 10 sec

ITSM
Parameter Value
Personality Module Part Number 2755389-01
Personality Module Release Date Apr05
Personality Module Description ITSM VER 0.1
ITSM Application Type V16,2 Turbos

Logged Diagnostic Codes [Diagnostic Clock = 10142:40:11 hours] - ITSM


Code Description Occ. First Last
1489- 5 Left Turbo Turbine Outlet Temperature Sensor : 4 10045:42:2 10050:08:4
Current Below Normal 9 5
1490- 5 Right Turbo Turbine Outlet Temperature Sensor : 4 10045:42:2 10050:08:4
Current Below Normal 9 5

Logged Event Codes [Diagnostic Clock = 10142:40:11 hours] - ITSM


Code Description Occ. First Last
E243 (1) High Left Turbocharger Turbine Outlet 3 9997:51:09 10045:01:1
Temperature 9
E243 (3) High Left Turbocharger Turbine Outlet 3 9997:51:09 10045:01:1
Temperature 9
E244 (1) High Right Turbocharger Turbine Outlet 1 10131:29:1 10131:29:1
Temperature 8 8
E244 (3) High Right Turbocharger Turbine Outlet 1 10131:29:1 10131:29:1
Temperature 8 8

Active Diagnostic Codes - ITSM


Code Description
No Active
Diagnostic
Codes

Active Event Codes - ITSM


Code Description
No Active
Event Codes

Configuration - ITSM
Description Value Unit
ITSM Application Type V16,2 Turbos
Total Tattletale 0

Monitoring System - ITSM


Description State Trip Point Delay Time
Exhaust Port
Temperature High
Deviation
Least Severe (1) On 90 Deg F 60 sec
Most Severe (3) On 360 Deg F 10 sec
Exhaust Port
Temperature Low
Deviation
Least Severe (1) On 90 Deg F 60 sec
Most Severe (3) On 360 Deg F 10 sec
High Exhaust
Temperature
Least Severe (1) On 1292 Deg F 30 sec
Most Severe (3) On 1292 Deg F 30 sec
High Turbo Turbine
Inlet Temperature
Least Severe (1) On 1310 Deg F 60 sec
Most Severe (3) On 1346 Deg F 30 sec
High Turbo Turbine
Outlet Temperature
Least Severe (1) On 1157 Deg F 60 sec
Most Severe (3) On 1157 Deg F 60 sec

PL1000E #2
Parameter Value
ECM Part Number 3461903-00
ECM Serial Number 0382B010TE
Personality Module Part Number 3764410-00
Personality Module Release Date MAR11
Personality Module Description PL1000E Communication ECU

Current Totals - PL1000E #2


Description Value Unit
ECM Lifetime Clock 3883 hours

Configuration - PL1000E #2
Description Value Unit
CAT Data Link Module Identifier PL1000 #2
Configuration
Ethernet Media Access Control (MAC) 00:0A:75:01:DC:36
Address
Internet Protocol Host Name PL1000E
Internet Protocol (IPv4) Address 192.168.1.53
Internet Protocol (IPv4) Network Mask 255.255.255.0
Network Default Gateway Internet Protocol 0.0.0.0
(IPv4) Address
Web Server Administrator Password admin
Dynamic Host Configuration Protocol Disabled
(DHCP) Enable Status
Modbus #1 Port Selection Serial Port #1
ModBus #1 Baud Rate 9600
ModBus #1 Echo/ No Echo No Echo
ModBus #1 Flow Control None
ModBus #1 Data Size 8
ModBus #1 Parity No Parity
Modbus #2 Port Selection Serial Port #2
ModBus #2 Baud Rate 9600
ModBus #2 Echo/ No Echo No Echo
ModBus #2 Flow Control None
ModBus #2 Data Size 8
ModBus #2 Parity No Parity
Modbus #3 Port Selection Serial Port #4
ModBus #3 Baud Rate 9600
ModBus #3 Echo/ No Echo No Echo
ModBus #3 Flow Control None
ModBus #3 Data Size 8
ModBus #3 Parity No Parity
RS-485 Mode 4-wire
Modbus TCP Data Link Address 254

EMCP 4.2
Parameter Value
ECM Part Number 3518758-02
ECM Serial Number 1012B217TX
Software Group Part Number 3911270-00
Software Group Release Date NOV2011
Software Group Description A5L1_1_1_1_Prod_Complex English, 4.1.1c
PROD, 08November2011

Logged Diagnostic Codes [SHM: 10144 RTC: 25/09/1936 20:21:45] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
3581-11 Modbus Data Link : Other 8 10047:33:4 10135:49:4 01/05/2021 24/09/2021
Failure Mode 3 3 17:18:45 09:05:04
190- 5 Engine Speed : Current 7 10013:13:3 10130:37:3 09/03/2021 16/08/2021
Below Normal 3 3 15:38:58 11:00:04
1383-11 Engine was Shut Down 1 10039:12:4 10039:12:4 11/03/2021 11/03/2021
Hot : Other Failure Mode 5 5 11:32:49 11:32:49

Logged Event Codes [SHM: 10144 RTC: 25/09/1936 20:21:45] - EMCP 4.2
Code Description Occ. SHM First SHM Last RTC First RTC Last
110-15 Engine Coolant 1 10045:15:4 10045:15:4 20/03/2021 20/03/2021
Temperature : High - least 2 2 17:04:20 17:04:20
severe (1)
190- 1 Engine Speed : Low - 2 10130:38:0 10144:05:5 14/08/2021 25/09/2021
most severe (3) 5 3 12:56:56 19:39:26
190-17 Engine Speed : Low - 2 10130:38:0 10144:05:5 14/08/2021 25/09/2021
least severe (1) 5 2 12:56:56 19:39:25
703-31 Auxiliary I/O #03 8 9999:01:33 10014:41:0 28/01/2021 09/03/2021
3 23:03:43 19:21:22
706-31 Auxiliary I/O #06 50 9995:46:33 10003:30:2 27/01/2021 01/02/2021
4 22:02:04 03:51:36
970-31 Engine Auxiliary Engine 20 9995:46:33 10133:52:3 27/01/2021 20/09/2021
Shutdown Switch 3 22:02:03 11:21:51
1664-31 Engine Automatic Start 2 10053:55:4 10053:55:3 24/06/2021 24/06/2021
Failed 8 3 17:25:34 17:30:43
2436- 1 Generator Average AC 12 10005:24:3 10144:05:5 02/02/2021 25/09/2021
Frequency : Low - most 2 1 22:51:17 19:39:24
severe (3)
2436-15 Generator Average AC 2 10013:18:3 10013:19:3 09/03/2021 09/03/2021
Frequency : High - least 9 2 16:15:08 16:16:01
severe (1)
2436-17 Generator Average AC 15 9998:55:17 10144:05:5 28/01/2021 25/09/2021
Frequency : Low - least 1 06:51:05 19:39:24
severe (1)
2440- 0 Generator Average Line- 1 10067:37:4 10067:37:4 29/06/2021 29/06/2021
Line AC RMS Voltage : 9 9 14:55:14 14:55:14
High - most severe (3)
2440- 1 Generator Average Line- 12 10045:29:0 10144:05:5 29/04/2021 25/09/2021
Line AC RMS Voltage : 4 1 16:51:32 19:39:24
Low - most severe (3)
2440-15 Generator Average Line- 1 10067:37:4 10067:37:4 29/06/2021 29/06/2021
Line AC RMS Voltage : 9 9 14:55:14 14:55:14
High - least severe (1)
2440-17 Generator Average Line- 21 10005:24:3 10144:05:5 02/02/2021 25/09/2021
Line AC RMS Voltage : 2 1 22:51:17 19:39:24
Low - least severe (1)
2456-15 Generator Total Reactive 1 10044:31:1 10044:31:1 19/03/2021 19/03/2021
Power : High - least 1 1 14:24:19 14:24:19
severe (1)
4025-31 Generator Phase 4 10067:34:1 10067:36:2 28/06/2021 29/06/2021
Sequence Incorrect 8 6 17:09:46 10:56:25

Active Diagnostic Codes [SHM: 10144 RTC: 25/09/1936 20:21:45] - EMCP 4.2
Code Description Occ.
No Active
Diagnostic
Codes

Active Event Codes [SHM: 10144 RTC: 25/09/1936 20:21:45] - EMCP 4.2
Code Description Occ.
4007-31 Generator Control not in Automatic 0

Current Totals - EMCP 4.2


Description Value Unit
Total Operating Hours 10144.1 hours
Generator Total kW Hours 10011898 KW-hr
Export

Configuration - EMCP 4.2


Description Value Unit
Analog Input #1 Signal Type Disabled
Analog Input #2 Signal Type Disabled
Analog Input #3 Signal Type Disabled
Analog Input Supply Voltage 5 Volt
Engine Start Fault Protection Activation 30 sec
Delay Time
Crank Duration 15 sec
Crank Cycle Rest Interval 10 sec
Engine Purge Cycle Time 0 sec
Maximum Number of Crank Cycles 5
Cooldown Duration 0 min
Start Aid Activation Time 30 sec
Crank Alert Activation Time 0 sec
Crank Terminate RPM 350 rpm
Engine Fuel Type Configuration Diesel
Fuel Shutoff Solenoid Type Configuration Energized to Run
Engine Cooldown Speed Configuration Rated Speed
Engine Operating State Input Configuration Hardwired Input
Fuel Priming Feature Enable Status Disabled
Engine Forced Idle Feature Enable Status Enabled
Emergency Stop Switch Active State High
Configuration
High Battery Voltage Warning Event 30.0 Volts
Threshold
High Battery Voltage Warning Event 10 sec
Notification Delay Time
High Battery Voltage Shutdown Event 32.0 Volts
Threshold
High Battery Voltage Shutdown Event 2 sec
Notification Delay Time
Low Battery Voltage Warning Event 23.4 Volts
Threshold
Low Battery Voltage Warning Event 30 sec
Notification Delay Time
Low Battery Charging System Voltage 25.0 Volts
Warning Event Threshold
Low Battery Charging System Voltage 30 sec
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event 21.0 Volts
Threshold
Low Cranking Voltage Warning Event 10 sec
Notification Delay Time
Customer Password Security Level to 3-Factory, Single Use
Reset Crank/Start Counters
SCADA Data Link Baud Rate 19200 baud
SCADA Data Link Parity None
SCADA Data Link Slave Address 3
SCADA Data Link Access Password 00000000
RS-485 Bias Resistor Enable Status Enabled
Digital Input #1 Usage Type Disabled
Digital Input #2 Usage Type Disabled
Digital Input #3 Usage Type Disabled
Digital Input #4 Usage Type Disabled
Digital Input #5 Usage Type Disabled
Digital Input #6 Usage Type Disabled
Digital Output #1 Usage Type Command/Status Parameter
Digital Output #1 Command/Status Disable Aux AC Supply
Parameter Data Identification
Digital Output #2 Usage Type Command/Status Parameter
Digital Output #2 Command/Status Run Mode
Parameter Data Identification
Engine Coolant Temperature Sensor Data Link
Configuration
High Engine Coolant Temperature Warning 216 Deg F
Event Threshold
High Engine Coolant Temperature Warning 10 sec
Event Notification Delay Time
High Engine Coolant Temperature 225 Deg F
Shutdown Event Threshold
High Engine Coolant Temperature 20 sec
Shutdown Event Notification Delay Time
Low Engine Coolant Temperature Warning 70 Deg F
Event Threshold
Low Engine Coolant Temperature Warning 30 sec
Event Notification Delay Time
Engine Oil Pressure Sensor Configuration Data Link
Low Engine Oil Pressure Warning Event 38 psi
Threshold
Low Idle Low Engine Oil Pressure Warning 15 psi
Event Threshold
Low Engine Oil Pressure Warning Event 30 sec
Notification Delay Time
Low Engine Oil Pressure Shutdown Event 30 psi
Threshold
Low Idle Low Engine Oil Pressure 10 psi
Shutdown Event Threshold
Low Engine Oil Pressure Shutdown Event 0 sec
Notification Delay Time
Low Engine Oil Pressure Step Speed 1200 rpm
Flywheel Teeth 183
Engine Overspeed Setpoint 2175 rpm
Engine Underspeed Warning Event 1400 rpm
Threshold
Engine Underspeed Warning Event 10.0 sec
Notification Delay Time
Engine Underspeed Shutdown Event 1300 rpm
Threshold
Engine Underspeed Shutdown Event 10.0 sec
Notification Delay Time
Engine Speed Sensor Configuration Sensor
Generator Drive Ratio 1.000 Ratio
Engine Cylinder Temperature Sensor Not Installed
Installation Status
Number of Engine Cylinders 1
Generator Winding Temperature Sensor Not Installed
Installation Status
Generator Bearing Temperature Sensor Not Installed
Installation Configuration
Accessory Data Link Diagnostic Response Activate Warning Condition
Configuration
Accessory Data Link Diagnostic Audible Yes
Alert
Accessory Data Link Diagnostic Breaker #1 No
Trip
Accessory Data Link Diagnostic Breaker #2 No
Trip
Engine Speed Sensor Diagnostic Activate Hard Shutdown Condition
Response Configuration
Engine Speed Sensor Diagnostic Audible Yes
Alert
Engine Speed Sensor Diagnostic Breaker No
#1 Trip
Engine Speed Sensor Diagnostic Breaker No
#2 Trip
Primary Data Link Diagnostic Response Activate Warning Condition
Configuration
Primary Data Link Diagnostic Audible Alert No
Primary Data Link Diagnostic Breaker #1 No
Trip
Primary Data Link Diagnostic Breaker #2 No
Trip
RS-485 SCADA Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 SCADA Data Link Diagnostic No
Audible Alert
RS-485 SCADA Data Link Diagnostic No
Breaker #1 Trip
RS-485 SCADA Data Link Diagnostic No
Breaker #2 Trip
RS-485 SCADA Data Link Diagnostic Fault No
Protection Timer
RS-485 Annunciator Data Link Diagnostic Activate Warning Condition
Response Configuration
RS-485 Annunciator Data Link Diagnostic No
Audible Alert
RS-485 Annunciator Data Link Diagnostic No
Breaker #1 Trip
RS-485 Annunciator Data Link Diagnostic No
Breaker #2 Trip
RS-485 Annunciator Data Link Diagnostic No
Fault Protection Timer
Battery Charger Failure Diagnostic Activate Warning Condition
Response Configuration
Battery Charger Failure Diagnostic Audible Yes
Alert
Engine Controller Not Responding Disable Condition
Diagnostic Response Configuration
Engine Controller Not Responding No
Diagnostic Audible Alert
Engine Controller Not Responding No
Diagnostic Breaker #1 Trip
Engine Controller Not Responding No
Diagnostic Breaker #2 Trip
Analog Input #1 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #1 Diagnostic Audible Alert No
Analog Input #1 Diagnostic Breaker #1 Trip No
Analog Input #1 Diagnostic Breaker #2 Trip No
Analog Input #2 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #2 Diagnostic Audible Alert No
Analog Input #2 Diagnostic Breaker #1 Trip No
Analog Input #2 Diagnostic Breaker #2 Trip No
Analog Input #3 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #3 Diagnostic Audible Alert No
Analog Input #3 Diagnostic Breaker #1 Trip No
Analog Input #3 Diagnostic Breaker #2 Trip No
Air Damper Closed Event Response Hard Shutdown & Active Only
Configuration Condition
Air Damper Closed Event Audible Alert Yes
Emergency Stop Activated Event Activate Hard Shutdown Condition
Response Configuration
Emergency Stop Activated Event Audible Yes
Alert
Emergency Stop Activated Event Breaker No
#1 Trip
Emergency Stop Activated Event Breaker No
#2 Trip
High Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
High Engine Coolant Level Warning Event Yes
Audible Alert
High Engine Coolant Level Warning Event No
Breaker #1 Trip
High Engine Coolant Level Warning Event No
Breaker #2 Trip
High Engine Coolant Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Coolant Level Shutdown Yes
Event Audible Alert
High Engine Coolant Level Shutdown No
Event Breaker #1 Trip
High Engine Coolant Level Shutdown No
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Coolant Level Warning Event Yes
Audible Alert
Low Engine Coolant Level Warning Event No
Breaker #1 Trip
Low Engine Coolant Level Warning Event No
Breaker #2 Trip
Low Engine Coolant Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Coolant Level Shutdown Event Yes
Audible Alert
Low Engine Coolant Level Shutdown Event No
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event No
Breaker #2 Trip
High Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Coolant Temperature Warning Yes
Event Audible Alert
High Engine Coolant Temperature Warning No
Event Breaker #1 Trip
High Engine Coolant Temperature Warning No
Event Breaker #2 Trip
High Engine Coolant Temperature Warning Yes
Event Fault Protection Timer
High Engine Coolant Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Engine Coolant Temperature Yes
Shutdown Event Audible Alert
High Engine Coolant Temperature No
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature No
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature Yes
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Coolant Temperature Warning Yes
Event Audible Alert
Low Engine Coolant Temperature Warning No
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning No
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning No
Event Fault Protection Timer
Engine Failure To Start Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Failure To Start Shutdown Event Yes
Audible Alert
Engine Failure To Start Shutdown Event No
Breaker #1 Trip
Engine Failure To Start Shutdown Event No
Breaker #2 Trip
High Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
High Engine Oil Level Warning Event Yes
Audible Alert
High Engine Oil Level Warning Event No
Breaker #1 Trip
High Engine Oil Level Warning Event No
Breaker #2 Trip
High Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Engine Oil Level Shutdown Event Yes
Audible Alert
High Engine Oil Level Shutdown Event No
Breaker #1 Trip
High Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Level Warning Event Yes
Audible Alert
Low Engine Oil Level Warning Event No
Breaker #1 Trip
Low Engine Oil Level Warning Event No
Breaker #2 Trip
Low Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Level Shutdown Event Yes
Audible Alert
Low Engine Oil Level Shutdown Event No
Breaker #1 Trip
Low Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Pressure Warning Event Yes
Audible Alert
Low Engine Oil Pressure Warning Event No
Breaker #1 Trip
Low Engine Oil Pressure Warning Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Yes
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Pressure Shutdown Event Yes
Audible Alert
Low Engine Oil Pressure Shutdown Event No
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event Yes
Fault Protection Timer
High Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Oil Temperature Warning Yes
Event Audible Alert
High Engine Oil Temperature Warning No
Event Breaker #1 Trip
High Engine Oil Temperature Warning No
Event Breaker #2 Trip
High Engine Oil Temperature Warning No
Event Fault Protection Timer
High Engine Oil Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Oil Temperature Shutdown Yes
Event Audible Alert
High Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Low Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Oil Temperature Warning Yes
Event Audible Alert
Low Engine Oil Temperature Warning No
Event Breaker #1 Trip
Low Engine Oil Temperature Warning No
Event Breaker #2 Trip
Low Engine Oil Temperature Warning Yes
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown Disable Condition
Event Response Configuration
Low Engine Oil Temperature Shutdown No
Event Audible Alert
Low Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Unexpected Engine Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Unexpected Engine Shutdown Event Yes
Audible Alert
Unexpected Engine Shutdown Event No
Breaker #1 Trip
Unexpected Engine Shutdown Event No
Breaker #2 Trip
Engine Overspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Overspeed Shutdown Event Yes
Audible Alert
Engine Overspeed Shutdown Event No
Breaker #1 Trip
Engine Overspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Warning Event Activate Warning Condition
Response Configuration
Engine Underspeed Warning Event Audible Yes
Alert
Engine Underspeed Warning Event No
Breaker #1 Trip
Engine Underspeed Warning Event No
Breaker #2 Trip
Engine Underspeed Warning Event Fault Yes
Protection Timer
Engine Underspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Underspeed Shutdown Event Yes
Audible Alert
Engine Underspeed Shutdown Event No
Breaker #1 Trip
Engine Underspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault Yes
Protection Timer
High Exhaust Temperature Warning Event Disable Condition
Response Configuration
High Exhaust Temperature Warning Event No
Audible Alert
High Exhaust Temperature Warning Event No
Breaker #1 Trip
High Exhaust Temperature Warning Event No
Breaker #2 Trip
High Exhaust Temperature Warning Event No
Fault Protection Timer
High Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Exhaust Temperature Shutdown Yes
Event Audible Alert
High Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
Low Exhaust Temperature Warning Event Yes
Audible Alert
Low Exhaust Temperature Warning Event No
Breaker #1 Trip
Low Exhaust Temperature Warning Event No
Breaker #2 Trip
Low Exhaust Temperature Warning Event Yes
Fault Protection Timer
Low Exhaust Temperature Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Exhaust Temperature Shutdown Event Yes
Audible Alert
Low Exhaust Temperature Shutdown Event No
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event No
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event Yes
Fault Protection Timer
High Fuel Level Warning Event Response Activate Warning Condition
Configuration
High Fuel Level Warning Event Audible Yes
Alert
High Fuel Level Warning Event Breaker #1 No
Trip
High Fuel Level Warning Event Breaker #2 No
Trip
High Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
High Fuel Level Shutdown Event Audible Yes
Alert
High Fuel Level Shutdown Event Breaker No
#1 Trip
High Fuel Level Shutdown Event Breaker No
#2 Trip
Low Fuel Level Warning Event Response Activate Warning Condition
Configuration
Low Fuel Level Warning Event Audible Yes
Alert
Low Fuel Level Warning Event Breaker #1 No
Trip
Low Fuel Level Warning Event Breaker #2 No
Trip
Low Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
Low Fuel Level Shutdown Event Audible Yes
Alert
Low Fuel Level Shutdown Event Breaker No
#1 Trip
Low Fuel Level Shutdown Event Breaker No
#2 Trip
External Tank High Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank High Fuel Level Warning Yes
Event Audible Alert
External Tank High Fuel Level Warning No
Event Breaker #1 Trip
External Tank High Fuel Level Warning No
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank High Fuel Level Shutdown Yes
Event Audible Alert
External Tank High Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown No
Event Breaker #2 Trip
External Tank Low Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank Low Fuel Level Warning Yes
Event Audible Alert
External Tank Low Fuel Level Warning No
Event Breaker #1 Trip
External Tank Low Fuel Level Warning No
Event Breaker #2 Trip
External Tank Low Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank Low Fuel Level Shutdown Yes
Event Audible Alert
External Tank Low Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown No
Event Breaker #2 Trip
Fuel Leak Event Response Configuration Activate Warning Condition
Fuel Leak Event Audible Alert Yes
Fuel Leak Event Breaker #1 Trip No
Fuel Leak Event Breaker #2 Trip No
Service Maintenance Interval Warning Disable Condition
Event Response Configuration
Service Maintenance Interval Warning No
Event Audible Alert
High Gas Pressure Warning Event Activate Warning Condition
Response Configuration
High Gas Pressure Warning Event Audible Yes
Alert
High Gas Pressure Warning Event Breaker No
#1 Trip
High Gas Pressure Warning Event Breaker No
#2 Trip
High Gas Pressure Shutdown Event Disable Condition
Response Configuration
High Gas Pressure Shutdown Event Yes
Audible Alert
High Gas Pressure Shutdown Event No
Breaker #1 Trip
High Gas Pressure Shutdown Event No
Breaker #2 Trip
Low Gas Pressure Warning Event Activate Warning Condition
Response Configuration
Low Gas Pressure Warning Event Audible Yes
Alert
Low Gas Pressure Warning Event Breaker No
#1 Trip
Low Gas Pressure Warning Event Breaker No
#2 Trip
Low Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Gas Pressure Shutdown Event Yes
Audible Alert
Low Gas Pressure Shutdown Event No
Breaker #1 Trip
Low Gas Pressure Shutdown Event No
Breaker #2 Trip
Engine Intake Manifold Charge Activate Warning Condition
Combustion Event Response Configuration
Engine Intake Manifold Charge Yes
Combustion Event Audible Alert
Engine Intake Manifold Charge No
Combustion Event Breaker #1 Trip
Engine Intake Manifold Charge No
Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge Yes
Combustion Event Fault Protection Timer
Remote Emergency Stop Activated Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Remote Emergency Stop Activated Yes
Shutdown Event Audible Alert
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #1 Trip
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
High Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
High Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature Yes
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
Low Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
Low Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature Yes
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature Disable Condition
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature No
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Generator Overcurrent Warning Event Activate Warning Condition
Response Configuration
Generator Overcurrent Warning Event Yes
Audible Alert
Generator Overcurrent Warning Event No
Breaker #1 Trip
Generator Overcurrent Warning Event No
Breaker #2 Trip
Generator Overcurrent Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Overcurrent Shutdown Event Yes
Audible Alert
Generator Overcurrent Shutdown Event No
Breaker #1 Trip
Generator Overcurrent Shutdown Event No
Breaker #2 Trip
Generator Over Frequency Warning Event Activate Warning Condition
Response Configuration
Generator Over Frequency Warning Event Yes
Audible Alert
Generator Over Frequency Warning Event No
Breaker #1 Trip
Generator Over Frequency Warning Event No
Breaker #2 Trip
Generator Over Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Over Frequency Shutdown Yes
Event Audible Alert
Generator Over Frequency Shutdown No
Event Breaker #1 Trip
Generator Over Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Warning Activate Warning Condition
Event Response Configuration
Generator Under Frequency Warning Yes
Event Audible Alert
Generator Under Frequency Warning No
Event Breaker #1 Trip
Generator Under Frequency Warning No
Event Breaker #2 Trip
Generator Under Frequency Warning Yes
Event Fault Protection Timer
Generator Under Frequency Shutdown Disable Condition
Event Response Configuration
Generator Under Frequency Shutdown Yes
Event Audible Alert
Generator Under Frequency Shutdown Yes
Event Breaker #1 Trip
Generator Under Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Shutdown Yes
Event Fault Protection Timer
Generator Reverse Power Warning Event Activate Warning Condition
Response Configuration
Generator Reverse Power Warning Event Yes
Audible Alert
Generator Reverse Power Warning Event No
Breaker #1 Trip
Generator Reverse Power Warning Event No
Breaker #2 Trip
Generator Reverse Power Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Reverse Power Shutdown Event Yes
Audible Alert
Generator Reverse Power Shutdown Event No
Breaker #1 Trip
Generator Reverse Power Shutdown Event No
Breaker #2 Trip
Generator Over Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Over Voltage Warning Event Yes
Audible Alert
Generator Over Voltage Warning Event No
Breaker #1 Trip
Generator Over Voltage Warning Event No
Breaker #2 Trip
Generator Over Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Over Voltage Shutdown Event Yes
Audible Alert
Generator Over Voltage Shutdown Event No
Breaker #1 Trip
Generator Over Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Under Voltage Warning Event Yes
Audible Alert
Generator Under Voltage Warning Event Yes
Breaker #1 Trip
Generator Under Voltage Warning Event Yes
Breaker #2 Trip
Generator Under Voltage Warning Event Yes
Fault Protection Timer
Generator Under Voltage Shutdown Event Disable Condition
Response Configuration
Generator Under Voltage Shutdown Event Yes
Audible Alert
Generator Under Voltage Shutdown Event No
Breaker #1 Trip
Generator Under Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Shutdown Event Yes
Fault Protection Timer
Earth Fault Event Response Configuration Activate Hard Shutdown Condition
Earth Fault Event Audible Alert Yes
Earth Fault Event Breaker #1 Trip No
Earth Fault Event Breaker #2 Trip No
Generator Winding #1 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #1 High Temperature Yes
Warning Event Audible Alert
Generator Winding #1 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #1 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #1 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Shutdown Event Fault Protection Timer
Generator High Power Warning Event Activate Warning Condition
Response Configuration
Generator High Power Warning Event Yes
Audible Alert
Generator High Power Warning Event No
Breaker #1 Trip
Generator High Power Warning Event No
Breaker #2 Trip
Generator Reverse Reactive Power Activate Warning Condition
Warning Event Response Configuration
Generator Reverse Reactive Power No
Warning Event Audible Alert
Generator Reverse Reactive Power No
Warning Event Breaker #1 Trip
Generator Reverse Reactive Power No
Warning Event Breaker #2 Trip
Generator Reverse Reactive Power Disable Condition
Shutdown Event Response Configuration
Generator Reverse Reactive Power No
Shutdown Event Audible Alert
Generator Reverse Reactive Power No
Shutdown Event Breaker #1 Trip
Generator Reverse Reactive Power No
Shutdown Event Breaker #2 Trip
High Battery Voltage Warning Event Activate Warning Condition
Response Configuration
High Battery Voltage Warning Event Yes
Audible Alert
High Battery Voltage Warning Event No
Breaker #1 Trip
High Battery Voltage Warning Event No
Breaker #2 Trip
High Battery Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
High Battery Voltage Shutdown Event Yes
Audible Alert
High Battery Voltage Shutdown Event No
Breaker #1 Trip
High Battery Voltage Shutdown Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Activate Warning Condition
Response Configuration
Low Battery Voltage Warning Event Yes
Audible Alert
Low Battery Voltage Warning Event No
Breaker #1 Trip
Low Battery Voltage Warning Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Fault No
Protection Timer
Low Battery Charging System Voltage Disable Condition
Warning Event Response Configuration
Low Battery Charging System Voltage No
Warning Event Audible Alert
Low Battery Charging System Voltage No
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage No
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage No
Warning Event Fault Protection Timer
Generator Breaker Open Event Response Active Only Condition
Configuration
Generator Breaker Open Event Audible No
Alert
Generator Breaker Closed Event Response Active Only Condition
Configuration
Generator Breaker Closed Event Audible No
Alert
Engine In Cooldown Event Response Active Only Condition
Configuration
Engine In Cooldown Event Audible Alert No
Engine Speed-Generator Output Freq Activate Warning Condition
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq Yes
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #2 Trip
Generator Control Not in Automatic Activate Warning Condition
Warning Event Response Configuration
Generator Control Not in Automatic Yes
Warning Event Audible Alert
Emergency Power System Supplying Load Warning & Active Only Condition
Event Response Configuration
Emergency Power System Supplying Load No
Event Audible Alert
Low Cranking Voltage Warning Event Disable Condition
Response Configuration
Low Cranking Voltage Warning Event No
Audible Alert
Low Cranking Voltage Warning Event No
Breaker #1 Trip
Low Cranking Voltage Warning Event No
Breaker #2 Trip
Analog Input #1 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Custom Event #1 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #1 Condition Exists Event No
Audible Alert
Custom Event #1 Condition Exists Event No
Breaker #1 Trip
Custom Event #1 Condition Exists Event No
Breaker #2 Trip
Custom Event #1 Condition Exists Event No
Fault Protection Timer
Custom Event #2 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #2 Condition Exists Event No
Audible Alert
Custom Event #2 Condition Exists Event No
Breaker #1 Trip
Custom Event #2 Condition Exists Event No
Breaker #2 Trip
Custom Event #2 Condition Exists Event No
Fault Protection Timer
Custom Event #3 Condition Exists Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #3 Condition Exists Event No
Audible Alert
Custom Event #3 Condition Exists Event No
Breaker #1 Trip
Custom Event #3 Condition Exists Event No
Breaker #2 Trip
Custom Event #3 Condition Exists Event No
Fault Protection Timer
Custom Event #4 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #4 Condition Exists Event No
Audible Alert
Custom Event #4 Condition Exists Event No
Breaker #1 Trip
Custom Event #4 Condition Exists Event No
Breaker #2 Trip
Custom Event #4 Condition Exists Event No
Fault Protection Timer
Custom Event #5 Condition Exists Event Activate Warning Condition
Response Configuration
Custom Event #5 Condition Exists Event No
Audible Alert
Custom Event #5 Condition Exists Event No
Breaker #1 Trip
Custom Event #5 Condition Exists Event No
Breaker #2 Trip
Custom Event #5 Condition Exists Event No
Fault Protection Timer
Custom Event #6 Condition Exists Event Activate Hard Shutdown Condition
Response Configuration
Custom Event #6 Condition Exists Event Yes
Audible Alert
Custom Event #6 Condition Exists Event No
Breaker #1 Trip
Custom Event #6 Condition Exists Event No
Breaker #2 Trip
Custom Event #6 Condition Exists Event No
Fault Protection Timer
DIO #1 Custom Event # 1 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 1 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 1 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 1 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 1 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 2 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 2 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 2 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 2 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 2 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 3 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 3 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 3 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 3 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 3 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 4 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 4 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 4 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 4 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 4 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 5 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 5 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 5 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 5 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 5 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 6 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 6 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 6 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 6 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 6 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 7 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 7 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 7 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 7 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 7 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 8 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 8 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 8 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 8 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 8 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event # 9 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event # 9 Condition Exists No
Event Audible Alert
DIO #1 Custom Event # 9 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event # 9 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event # 9 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event #10 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event #10 Condition Exists No
Event Audible Alert
DIO #1 Custom Event #10 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event #10 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event #10 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event #11 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event #11 Condition Exists No
Event Audible Alert
DIO #1 Custom Event #11 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event #11 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event #11 Condition Exists No
Event Fault Protection Timer
DIO #1 Custom Event #12 Condition Exists Active Only Condition
Event Response Configuration
DIO #1 Custom Event #12 Condition Exists No
Event Audible Alert
DIO #1 Custom Event #12 Condition Exists No
Event Breaker #1 Trip
DIO #1 Custom Event #12 Condition Exists No
Event Breaker #2 Trip
DIO #1 Custom Event #12 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 1 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 1 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 1 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 1 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 1 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 2 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 2 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 2 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 2 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 2 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 3 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 3 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 3 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 3 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 3 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 4 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 4 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 4 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 4 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 4 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 5 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 5 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 5 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 5 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 5 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 6 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 6 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 6 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 6 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 6 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 7 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 7 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 7 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 7 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 7 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 8 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 8 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 8 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 8 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 8 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event # 9 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event # 9 Condition Exists No
Event Audible Alert
DIO #2 Custom Event # 9 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event # 9 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event # 9 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event #10 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event #10 Condition Exists No
Event Audible Alert
DIO #2 Custom Event #10 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event #10 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event #10 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event #11 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event #11 Condition Exists No
Event Audible Alert
DIO #2 Custom Event #11 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event #11 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event #11 Condition Exists No
Event Fault Protection Timer
DIO #2 Custom Event #12 Condition Exists Active Only Condition
Event Response Configuration
DIO #2 Custom Event #12 Condition Exists No
Event Audible Alert
DIO #2 Custom Event #12 Condition Exists No
Event Breaker #1 Trip
DIO #2 Custom Event #12 Condition Exists No
Event Breaker #2 Trip
DIO #2 Custom Event #12 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 1 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 1 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 1 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 1 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 1 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 2 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 2 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 2 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 2 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 2 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 3 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 3 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 3 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 3 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 3 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 4 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 4 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 4 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 4 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 4 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 5 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 5 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 5 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 5 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 5 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 6 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 6 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 6 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 6 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 6 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 7 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 7 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 7 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 7 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 7 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 8 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 8 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 8 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 8 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 8 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event # 9 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event # 9 Condition Exists No
Event Audible Alert
DIO #3 Custom Event # 9 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event # 9 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event # 9 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event #10 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event #10 Condition Exists No
Event Audible Alert
DIO #3 Custom Event #10 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event #10 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event #10 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event #11 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event #11 Condition Exists No
Event Audible Alert
DIO #3 Custom Event #11 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event #11 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event #11 Condition Exists No
Event Fault Protection Timer
DIO #3 Custom Event #12 Condition Exists Active Only Condition
Event Response Configuration
DIO #3 Custom Event #12 Condition Exists No
Event Audible Alert
DIO #3 Custom Event #12 Condition Exists No
Event Breaker #1 Trip
DIO #3 Custom Event #12 Condition Exists No
Event Breaker #2 Trip
DIO #3 Custom Event #12 Condition Exists No
Event Fault Protection Timer
Fuel Fill/Drain Feature Enable Status Disabled
Fuel Fill Activation Tank Level Percentage 5.0 %
Threshold
Fuel Fill Deactivation Tank Level 5.0 %
Percentage Threshold
Fuel Drain Deactivation Tank Level 5.0 %
Percentage Threshold
Generator Connection Configuration Wye (or Star) Connection
Generator Potential Transformer Primary 480 Volts
Winding Rating
Generator Potential Transformer 120 Volts
Secondary Winding Rating
Generator Current Transformer Primary 3500 Amps
Winding Rating
Generator Current Transformer Secondary 5 Amps
Winding Rating
Number of Generator Poles 4 Poles
Generator Rated Frequency #1 60.00 Hz
Generator Rated Voltage #1 480 Volts
Generator Rated Power #1 1475 kW
Generator Rated Apparent Power #1 1844 kVA
Generator Rated Frequency #2 45.00 Hz
Generator Rated Voltage #2 100 Volts
Generator Rated Power #2 1 kW
Generator Rated Apparent Power #2 1 kVA
Generator Rated Frequency #3 45.00 Hz
Generator Rated Voltage #3 100 Volts
Generator Rated Power #3 1 kW
Generator Rated Apparent Power #3 1 kVA
Generator Rated Frequency #4 45.00 Hz
Generator Rated Voltage #4 100 Volts
Generator Rated Power #4 1 kW
Generator Rated Apparent Power #4 1 kVA
Maximum Generator Voltage Output Bias 15 %
Percentage
Customer Password Security Level to 3-Factory, Single Use
Reset Generator Energy Meters
Generator Definite Time Overcurrent 110 %
Warning Event Percentage Threshold
Generator Inverse Time Overcurrent 0.27 sec
Shutdown Event Time Multiplier
Generator Definite Time Overcurrent 120 %
Shutdown Event Percentage Threshold
Generator Definite Time Overcurrent 10.0 sec
Shutdown Event Notification Delay Time
Generator Over Frequency Warning Event 110.0 %
Percentage Threshold
Generator Over Frequency Warning Event 10 sec
Notification Delay Time
Generator Over Frequency Shutdown 120.0 %
Event Percentage Threshold
Generator Over Frequency Shutdown 20 sec
Event Notification Delay Time
Generator Under Frequency Warning 95.0 %
Event Percentage Threshold
Generator Under Frequency Warning 10 sec
Event Notification Delay Time
Generator Under Frequency Shutdown 85.0 %
Event Percentage Threshold
Generator Under Frequency Shutdown 10 sec
Event Notification Delay Time
Generator Over Voltage Warning Event 110 %
Percentage Threshold
Generator Over Voltage Warning Event 10 sec
Notification Delay Time
Generator Over Voltage Shutdown Event 120 %
Percentage Threshold
Generator Over Voltage Shutdown Event 10 sec
Notification Delay Time
Generator Under Voltage Warning Event 90 %
Percentage Threshold
Generator Under Voltage Warning Event 10 sec
Notification Delay Time
Generator Under Voltage Shutdown Event 85 %
Percentage Threshold
Generator Under Voltage Shutdown Event 10 sec
Notification Delay Time
Generator Reverse Power Warning Event 5 %
Percentage Threshold
Generator Reverse Power Warning Event 10 sec
Notification Delay Time
Generator Reverse Power Shutdown Event 10 %
Percentage Threshold
Generator Reverse Power Shutdown Event 10 sec
Notification Delay Time
Generator Reverse Reactive Power 5.00 %
Warning Event Percentage Threshold
Generator Reverse Reactive Power 20 sec
Warning Event Notification Delay Time
Generator Reverse Reactive Power 15.00 %
Shutdown Event Percentage Threshold
Generator Reverse Reactive Power 20 sec
Shutdown Event Notification Delay Time
Programmable Cycle Timer #1 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #1 Activation Deactivate
Day - Monday
Programmable Cycle Timer #1 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #1 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #1 Activation Deactivate
Day - Friday
Programmable Cycle Timer #1 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #1 Activation 0 min
Start Time
Programmable Cycle Timer #1 Active Time 1 min
Programmable Cycle Timer #1 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #1 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #2 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #2 Activation Deactivate
Day - Monday
Programmable Cycle Timer #2 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #2 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #2 Activation Deactivate
Day - Friday
Programmable Cycle Timer #2 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #2 Activation 0 min
Start Time
Programmable Cycle Timer #2 Active Time 1 min
Programmable Cycle Timer #2 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #2 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #3 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #3 Activation Deactivate
Day - Monday
Programmable Cycle Timer #3 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #3 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #3 Activation Deactivate
Day - Friday
Programmable Cycle Timer #3 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #3 Activation 0 min
Start Time
Programmable Cycle Timer #3 Active Time 1 min
Programmable Cycle Timer #3 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #3 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #4 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #4 Activation Deactivate
Day - Monday
Programmable Cycle Timer #4 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #4 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #4 Activation Deactivate
Day - Friday
Programmable Cycle Timer #4 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #4 Activation 0 min
Start Time
Programmable Cycle Timer #4 Active Time 1 min
Programmable Cycle Timer #4 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #4 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #5 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #5 Activation Deactivate
Day - Monday
Programmable Cycle Timer #5 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #5 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #5 Activation Deactivate
Day - Friday
Programmable Cycle Timer #5 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #5 Activation 0 min
Start Time
Programmable Cycle Timer #5 Active Time 1 min
Programmable Cycle Timer #5 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #5 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #6 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #6 Activation Deactivate
Day - Monday
Programmable Cycle Timer #6 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #6 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #6 Activation Deactivate
Day - Friday
Programmable Cycle Timer #6 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #6 Activation 0 min
Start Time
Programmable Cycle Timer #6 Active Time 1 min
Programmable Cycle Timer #6 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #6 Output #2 Inactive
Activation Configuration
Programmable Cycle Timer #7 Activation Deactivate
Day - Sunday
Programmable Cycle Timer #7 Activation Deactivate
Day - Monday
Programmable Cycle Timer #7 Activation Deactivate
Day - Tuesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Wednesday
Programmable Cycle Timer #7 Activation Deactivate
Day - Thursday
Programmable Cycle Timer #7 Activation Deactivate
Day - Friday
Programmable Cycle Timer #7 Activation Deactivate
Day - Saturday
Programmable Cycle Timer #7 Activation 1 min
Start Time
Programmable Cycle Timer #7 Active Time 1 min
Programmable Cycle Timer #7 Output #1 Inactive
Activation Configuration
Programmable Cycle Timer #7 Output #2 Inactive
Activation Configuration
Electronic Control Module Reduced Power Enabled
Mode Enable Status
Electronic Control Module Reduced Power 30 min
Mode Delay Time
Relay Output #1 Usage Type Command/Status Parameter
Relay Output #1 Command/Status Starter Motor Relay
Parameter Data Identification
Relay Output #2 Usage Type Command/Status Parameter
Relay Output #2 Command/Status Fuel Control Relay
Parameter Data Identification
Relay Output #3 Usage Type System Event
Relay Output #3 Event Suspect Parameter Custom Event #1
Number
Relay Output #3 Event Trigger Condition Specific Event - Condition Exists
Relay Output #4 Usage Type Command/Status Parameter
Relay Output #4 Command/Status Common Shutdown
Parameter Data Identification
Relay Output #5 Usage Type Command/Status Parameter
Relay Output #5 Command/Status Start Aid
Parameter Data Identification
Relay Output #6 Usage Type Command/Status Parameter
Relay Output #6 Command/Status Common Warning
Parameter Data Identification
Relay Output #7 Usage Type Command/Status Parameter
Relay Output #7 Command/Status Engine Start Initiated
Parameter Data Identification
Relay Output #8 Usage Type Command/Status Parameter
Relay Output #8 Command/Status Auto Mode
Parameter Data Identification
Maintenance Level 1 Cycle Interval Hours 500 hours
Maintenance Level 1 Cycle Interval Days 365
Customer Password Security Level to 0-No Security
Reset Service Maintenance Interval
Programmable Trip Point Function #1 Disabled
Trigger Condition
Programmable Trip Point Function #1 0 %
Percentage Threshold
Programmable Trip Point Function #1 0 %
Hysteresis Percentage
Programmable Trip Point Function #1 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #1 Trip 0 sec
Deactivation Delay Time
Programmable Trip Point Function #2 Disabled
Trigger Condition
Programmable Trip Point Function #2 0 %
Percentage Threshold
Programmable Trip Point Function #2 0 %
Hysteresis Percentage
Programmable Trip Point Function #2 Trip 0 sec
Activation Delay Time
Programmable Trip Point Function #2 Trip 0 sec
Deactivation Delay Time
Engine Serial Number XL600180
Display Pressure Units Configuration bar
Display Temperature Units Configuration Degrees Centigrade (Celsius)
Display Volume Units Configuration liters