Professional Documents
Culture Documents
Table of Contents
1 Introduction................................................................................................................................... 16
1.1 Overview ............................................................................................................................ 16
1.2 System Log Message Format............................................................................................ 16
1.3 System Log Message Module List..................................................................................... 18
2 802.1X Messages......................................................................................................................... 21
2.1 DOT1X_LOG ..................................................................................................................... 21
2.2 DOT1X_LOG ..................................................................................................................... 22
2.3 DOT1X_LOG ..................................................................................................................... 22
2.4 DOT1XSOP_ACL_NOT_SUPPORT ................................................................................. 23
2.5 DOT1XSOP_ACL_NOT_CONFIGURED .......................................................................... 23
2.6 DOT1XSOP_ACL_DEL_FAILED....................................................................................... 23
2.7 DOT1XSOP_ACL_ADD_FAILED ...................................................................................... 24
2.8 DOT1XSOP_ACL_RESOUCE_EXHAUSTED .................................................................. 24
2.9 DOT1XSOP_ACL_CONFLICT_WITH_ MQC ................................................................... 24
2.10 DOT1XSOP_ACL_CONFLICT_WITH_ USERMAC........................................................ 25
2.11 DOT1XSOP_ACL_CONFLICT_WITH_FLOW_TEMPLATE ........................................... 25
2.12 DOT1XEAD_LOG ............................................................................................................ 26
2.13 DOT1XEAD_LOG ............................................................................................................ 26
2.14 DOT1XEAD_LOG ............................................................................................................ 26
2.15 DOT1XEAD_LOG ............................................................................................................ 27
2.16 DOT1XEAD_LOG ............................................................................................................ 27
4 ARP Messages............................................................................................................................. 29
4.1 ROUTECONFLICT ............................................................................................................ 29
4.2 DUPIFIP............................................................................................................................. 29
4.3 DUPVRRPIP ...................................................................................................................... 30
4.4 DUPGLOBALIP.................................................................................................................. 30
4.5 ARPDTC ............................................................................................................................ 31
4.6 SRC-MAC .......................................................................................................................... 31
Hangzhou H3C Technologies Co., Ltd. 1/220
COMWARE System Log Message
5 ASPF Messages........................................................................................................................... 32
5.1 SESS_LOG........................................................................................................................ 32
5.2 SMTP_INVALID_COMMAND............................................................................................ 33
5.3 HTTP_JAVA_BLOCK ........................................................................................................ 33
5.4 ASPF_LOGID_FTP_SESS_NOT_AUTH .......................................................................... 33
5.5 HOST_TCP_ALERT_ON................................................................................................... 34
10 CSPF Messages......................................................................................................................... 45
10.1 LOG ................................................................................................................................. 45
11 DEVM Messages........................................................................................................................ 46
11.1 BOARDREMOVE............................................................................................................. 46
11.2 BOARDOK ....................................................................................................................... 46
11.3 BOARDFAULT................................................................................................................. 47
11.4 BOARDLOADING ............................................................................................................ 47
11.5 CARDREMOVE ............................................................................................................... 48
11.6 CARDINSERT.................................................................................................................. 48
11.7 CARDFAULT ................................................................................................................... 49
11.8 POWERRECOVER ......................................................................................................... 49
11.9 MPOWERRECOVER ...................................................................................................... 50
11.10 SPOWERRECOVER ..................................................................................................... 50
11.11 POWERFAIL.................................................................................................................. 51
11.12 POWERABSENT........................................................................................................... 51
11.13 FANRECOVER .............................................................................................................. 51
11.14 FANFAIL ........................................................................................................................ 52
11.15 FANABSENT ................................................................................................................. 52
11.16 TEMPOK........................................................................................................................ 52
11.17 TEMPLOW..................................................................................................................... 53
11.18 TEMPUP ........................................................................................................................ 53
11.19 RPSNORMAL ................................................................................................................ 54
11.20 RPSABSENT ................................................................................................................. 54
11.21 CFINSERT ..................................................................................................................... 55
11.22 CFREMOVE................................................................................................................... 55
11.23 SYSTEMREBOOT......................................................................................................... 56
11.24 BOARDREBOOT........................................................................................................... 56
11.25 SUBCARDREBOOT ...................................................................................................... 57
11.26 CURRENTNORMAL...................................................................................................... 57
11.27 CURRENTSMALL ......................................................................................................... 58
11.28 CURRENTBIG ............................................................................................................... 58
11.29 VOLTNORMAL .............................................................................................................. 59
11.30 VOLTLOW ..................................................................................................................... 59
11.31 VOLTHIGH..................................................................................................................... 60
11.32 NOENOUGHMEM ......................................................................................................... 60
11.33 SAMEREQUEST ........................................................................................................... 61
11.34 ABORTLOAD................................................................................................................. 61
11.35 REQUESTINVALID ....................................................................................................... 62
Hangzhou H3C Technologies Co., Ltd. 3/220
COMWARE System Log Message
11.36 LOADFAIL...................................................................................................................... 62
11.37 LOADFINISH ................................................................................................................. 63
11.38 READFAIL ..................................................................................................................... 63
11.39 STARTSELF .................................................................................................................. 64
11.40 CANNOTOPEN.............................................................................................................. 64
11.41 MANYRESENT .............................................................................................................. 65
11.42 MANYINVALID............................................................................................................... 65
11.43 CHECKSUMERR........................................................................................................... 65
14 DHCPS Messages...................................................................................................................... 68
14.1 DHCPS_LOCAL_SERVER.............................................................................................. 68
15 DHCPSNOOP Messages........................................................................................................... 69
15.1 dhcpsnoop_log................................................................................................................. 69
15.2 dhcpsnoop_log................................................................................................................. 69
15.3 dhcpsnoop_log................................................................................................................. 69
15.4 dhcpsnoop_log................................................................................................................. 70
15.5 dhcpsnoop_log................................................................................................................. 70
16 DLDP Messages......................................................................................................................... 70
16.1 AuthenticationFailed ........................................................................................................ 71
16.2 UnidirectionalAuto............................................................................................................ 71
16.3 UnidirectionalManual ....................................................................................................... 71
16.4 UnidirectionalAutoEnhance ............................................................................................. 72
16.5 UnidirectionalManualEnhance ......................................................................................... 72
18 ETHOAM Messages................................................................................................................... 74
18.1 OAMENABLE................................................................................................................... 74
18.2 OAMDISABLE.................................................................................................................. 75
18.3 OAMDISOK...................................................................................................................... 75
18.4 OAMDISFAIL ................................................................................................................... 75
20 FILTER Messages...................................................................................................................... 86
20.1 IPFILTER ......................................................................................................................... 86
23 HA Messages ............................................................................................................................. 92
23.1 LOG ................................................................................................................................. 92
27 HWCM Messages....................................................................................................................... 96
27.1 EXIT ................................................................................................................................. 96
27.2 TRAPLOG........................................................................................................................ 96
27.3 CCOPY ............................................................................................................................ 97
29 IFNET Messages........................................................................................................................ 98
29.1 PORTTAG........................................................................................................................ 98
29.2 UPDOWN......................................................................................................................... 99
29.3 UPDOWN......................................................................................................................... 99
29.4 LINK UPDOWN................................................................................................................ 99
29.5 FLUX EXCEED UPPER LIMIT ...................................................................................... 100
29.6 FLUX BELLOW LOWER LIMIT ..................................................................................... 100
29.7 PORT STATUS TURNS TO CONTROLLED ................................................................ 101
29.8 PORT STATUS RETURNS TO NORMAL..................................................................... 102
44 LS Messages............................................................................................................................ 117
71 RM Messages........................................................................................................................... 182
71.1 RMLOG.......................................................................................................................... 182
1 Introduction
1.1 Overview
About the table in which the details of system log messages are filled, the
explanations of all the items of the table are stated here:
Item Description
Mnemonic The text string that uniquely describes the system message
Severity Level Single-digit code from 0 to 7 that indicates the severity of the message
This portion of the message might contain detailed information about the
event, such as terminal port numbers, network addresses, or addresses
that correspond to locations in the system memory address space.
Syslog Message
Because the information in these variable fields changes from message
to message, it is represented here by short strings enclosed in square
brackets ([ ]). A text string, for example, is represented as [string].
Variable Field The signification of the variable fields in syslog message format string
The action which triggers off system to send a syslog message. For the
Trigger Action
same syslog message, there is more than one trigger action possibly.
Recommended
The action to be done when such system log message occurs
Action
Trigger Action, Example and Recommended Action fields might occur many times in
the same table, if there are different trigger actions for that message. These three
fields should be bundled and sequenced by “Trigger Action->Example-
>Recommended Action” order.
This section describes system log messages as defined by the syslog protocol
(RFC3164) and how to understand the syslog message format.
① ② ③ ④/⑤/⑥ ⑦ ⑧
Element Description
Element Description
④ Module name
⑥ Mnemonic. The text string that uniquely describes the system message
The text string containing detailed information about the event or error
⑧
being reported
System log message severity level ranges from 0 to 7 and reflects the severity of the
condition, as defined in RFC3164. The lower the number is, the more serious the
situation is. The following table lists the severity levels.
Level Description
There are some variable fields representation in system log message format. The
representations (no case-sensitive) of variable fields and the type of information in the
fields as follows:
Representation Description
Representation Description
UCHAR Character
IPADDR IP address
DATE Date
TIME Time
GAUGE Gauge
TIMETICK Time
802.1X - 基于端口的网络接入控制协议
CLST Cluster 集群
FILTER 包过滤防火墙
HW Authentication Bypass
HABP HW旁路认证协议
Protocol
IP Customer Information
IPCIM IP用户信息管理
Management
Intermediate System-to-
Intermediate System intra-domain 中间系统到中间系统的域内路由信
ISIS
routing information exchange 息交换协议
protocol
LWPS
OPTMOD
PORTAL -
D信道的数据链路层协议(它定义
了网络接口上第2层实体间经D信道
Q921 -
交换信息的规则,同时支持第3层
实体的接入)
SHELL - 终端用户
SOCKET
TUNNEL - 隧道
2 802.1X Messages
This section contains the entire system log messages related to 802.1X.
2.1 DOT1X_LOG
Mnemonic DOT1X_LOG Severity Level 3
Recommended
No action is recommended.
Action
2.2 DOT1X_LOG
Mnemonic DOT1X_LOG Severity Level 3
Recommended
No action is recommended.
Action
2.3 DOT1X_LOG
Mnemonic DOT1X_LOG Severity Level 3
Recommended
Input correct username or password.
Action
2.4 DOT1XSOP_ACL_NOT_SUPPORT
Mnemonic DOT1XSOP_ACL_NOT_SUPPORT Severity Level 3
Trigger Action The authorization ACL from AAA server can’t be supported.
Recommended Reconfigure the authorization ACL and make sure the ACL group
Action number is between 2000~4999.
2.5 DOT1XSOP_ACL_NOT_CONFIGURED
Severity
Mnemonic DOT1XSOP_ACL_NOT_CONFIGURED 3
Level
2.6 DOT1XSOP_ACL_DEL_FAILED
Mnemonic DOT1XSOP_ACL_DEL_FAILED Severity Level 3
Recommended When this information occurs, there is some hardware fault with the
Action device. Please turn to technical support engineer.
2.7 DOT1XSOP_ACL_ADD_FAILED
Mnemonic DOT1XSOP_ACL_ADD_FAILED Severity Level 3
Recommended When this information occurs, it seems that there is some hardware
Action fault with the device. Please turn to technical support engineer.
2.8 DOT1XSOP_ACL_RESOUCE_EXHAUSTED
Severity
Mnemonic DOT1XSOP_ACL_RESOUCE_EXHAUSTED 3
Level
Recommended
Configure the authorization ACL correctly.
Action
Trigger Action Apply authorization ACL to a port that MQC is configured on it.
Recommended
Undo the MQC configuration on this port.
Action
Apply a link layer ACL to a port of which rules contain source MAC
Trigger Action
information.
Recommended Don’t configure the source MAC field of the rules in authorization
Action ACL.
2.11 DOT1XSOP_ACL_CONFLICT_WITH_FLOW_TEMPLATE
Severity
Mnemonic DOT1XSOP_ACL_CONFLICT_WITH_FLOW_TEMPLATE 3
Level
Syslog
[STRING]
Message
Apply authorization ACL to port failed because it conflicts with the flow
Explanation
template configured on this port.
Trigger Action The flow template conflicts with the authorization ACL.
Recommended
Reconfigure the flow-template on this port.
Action
2.12 DOT1XEAD_LOG
Mnemonic DOT1XEAD_LOG Severity Level 3
Recommended
Continue to set an EAD rule for another port.
Action
2.13 DOT1XEAD_LOG
Mnemonic DOT1XEAD_LOG Severity Level 3
Setting an EAD rule on the port failed because the rule does not
Explanation
exist.
Recommended
Continue to set an EAD rule for another port.
Action
2.14 DOT1XEAD_LOG
Mnemonic DOT1XEAD_LOG Severity Level 3
Setting an EAD rule on the port failed because the number of driver
Explanation
ACLs has reached the maximum!
Trigger Action The number of driver ACLs has reached the maximum!
Recommended
Continue to set an EAD rule for another port.
Action
2.15 DOT1XEAD_LOG
Mnemonic DOT1XEAD_LOG Severity Level 3
Setting an EAD rule on the port failed because the driver does not
Explanation
support the operation.
Recommended
Continue to set an EAD rule for another port.
Action
2.16 DOT1XEAD_LOG
Mnemonic DOT1XEAD_LOG Severity Level 3
Setting an EAD rule on the port failed because the rule already
Explanation
exists.
Recommended
Continue to set an EAD rule for another port.
Action
3 ADDR Messages
This section contains the entire system log messages related to IPV6 AM.
3.1 Information
Mnemonic Information Severity Level 2
Explanation The information when failing to get control block or add address
Recommended
No action is recommended.
Action
3.2 Information
Mnemonic Information Severity Level 2
Recommended
No action is recommended.
Action
3.3 RESOURCE
Variable Fields
Recommended
No action is recommended.
Action
4 ARP Messages
This section contains the entire system log messages related to ARP.
4.1 ROUTECONFLICT
Mnemonic ROUTECONFLICT Severity Level 3
$1: IP address
Variable Fields
$2: VrfIndex
The driver returns route conflict when the ARP entry is added to the
Explanation
driver.
If route conflict is found when ARP entry is added to the driver, this
Trigger Action
log is displayed.
Recommended
No action is recommended.
Action
4.2 DUPIFIP
$1: IP address
Recommended
No action is recommended.
Action
4.3 DUPVRRPIP
Mnemonic DUPVRRPIP Severity Level 3
$1: IP address
Recommended
No action is recommended.
Action
4.4 DUPGLOBALIP
$1: IP address
Variable Fields
$2: MAC Address
Recommended
No action is recommended.
Action
4.5 ARPDTC
Mnemonic ARPDTC Severity Level 4
$1:interface name
Variable Fields
$2:ip address
Trigger Action An invalid ARP packet is detected and dropped by ARP Detection.
Recommended
No action is recommended.
Action
4.6 SRC-MAC
Syslog Message \r\n An attack from MAC [string] was detected on interface [string].
$1:MAC address
Variable Fields
$2:interface name
Trigger Action Attack is detected by ARP fixed source MAC address anti-attack.
Recommended
No action is recommended.
Action
5 ASPF Messages
This section contains the entire system log messages related to ASPF.
5.1 SESS_LOG
Mnemonic SESS_LOG Severity Level 3
$2:.Source IP address
Recommended
No action is recommended.
Action
5.2 SMTP_INVALID_COMMAND
Mnemonic SMTP_INVALID_COMMAND Severity Level 2
Recommended
No action is recommended.
Action
5.3 HTTP_JAVA_BLOCK
Mnemonic HTTP_JAVA_BLOCK Severity Level 2
$1:.Source IP address
Trigger Action ASPF detects a request form user for java applet
Recommended
No action is recommended.
Action
5.4 ASPF_LOGID_FTP_SESS_NOT_AUTH
Severity
Mnemonic FTP_SESSION_NOT_AUTHENTICATED 2
Level
$1:.Source IP address
Variable Fields
$2: Destnation IP address
Recommended
No action is recommended.
Action
5.5 HOST_TCP_ALERT_ON
Mnemonic HOST_TCP_ALERT_ON Severity Level 2
$1:.IP address
Variable Fields
$2: Incomplete connection number
Recommended
No action is recommended.
Action
6 BFD Messages
This section contains the entire system log messages related to BFD
6.1 FSM
Mnemonic FSM Severity Level 4
Recommended
No action is recommended.
Action
6.2 no_echo_source_ip
Mnemonic No_echo_source_ip Severity Level 4
The source address located in bfd echo packet has not been
Syslog Message
specified, please set it
Variable Fields
Explanation Source address of bfd echo packet has not been configured.
Trigger Action Source address of bfd echo packet has not been configured.
Recommended
Please specify source address under system view.
Action
7 CFM Messages
This section contains the entire system log messages related to CFM.
7.1 CFM_LOG
Mnemonic CFM_LOG Severity Level 4
Recommended
Check sequence of the command string in configuration file.
Action
Variable Fields
Recommended
Check the configuration file
Action
Variable Fields
Configuration is skipped.
Recommended
Check the configuration gotten from auto-configuration
Action
Variable Fields
Recommended
Check the configuration
Action
Recommended
Check the configuration.
Action
8 CLST Messages
This section contains the entire system log messages related to CLST.
8.1 Info
Mnemonic Info Severity Level 5
Recommended
No action is recommended.
Action
8.2 Member
Recommended
No action is recommended.
Action
8.3 MemberJoinCluster
Mnemonic MemberJoinCluster Severity Level 4
Recommended
No action is recommended.
Action
8.4 JoinStack
Mnemonic JoinStack Severity Level 4
Recommended
No action is recommended.
Action
8.5 DeleteCluster
Mnemonic DeleteCluster Severity Level 4
Recommended
No action is recommended.
Action
8.6 DeleteStack
Mnemonic DeleteStack Severity Level 4
Recommended
No action is recommended.
Action
8.7 RejoinCluster
Mnemonic RejoinCluster Severity Level 4
Recommended
No action is recommended.
Action
8.8 AlreadyDown
Mnemonic AlreadyDown Severity Level 4
Recommended Check that if the communication between the administrator and the
Action member error or the member device is down.
8.9 SwitchJoinCluster
Severity
Mnemonic SwitchJoinCluster 4
Level
Recommended
No action is recommended.
Action
8.10 SwitchJoinStack
Severity
Mnemonic SwitchJoinStack 4
Level
Variable Fields -
Recommended
No action is recommended.
Action
8.11 SwitchDeleteCluster
Severity
Mnemonic SwitchDeleteCluster 4
Level
Recommended
No action is recommended.
Action
8.12 SwitchDeleteStack
Severity
Mnemonic SwitchDeleteStack 4
Level
Variable Fields -
Recommended
No action is recommended.
Action
8.13 CommandDown
Severity
Mnemonic CommandDown 4
Level
Variable Fields
Recommended Check that if the communication between the administrator and the
Action member error or the administrator is down.
8.14 SwitchRejoinCluster
Severity
Mnemonic SwitchRejoinCluster 4
Level
Variable Fields
When he member switch rejoind the cluster after shakehand error for
Trigger Action
sometime.
Recommended
No action is recommended.
Action
8.15 LOG
Mnemonic LOG Severity Level 4
Recommended
No action is recommended
Action
8.16 LOG
Mnemonic LOG Severity Level 4
Recommended
Check whether the member switch is in the white list.
Action
9 CMD Messages
This section contains the entire system log messages related to CMD.
9.1 REBOOT
Mnemonic REBOOT Severity Level 4
Recommended
No action is recommended.
Action
9.2 REBOOT
Mnemonic REBOOT Severity Level 4
Variable Fields
***
Example
*** --- REBOOT IN ONE MINUTE ---
***
Recommended
The device will reboot.
Action
9.3 REBOOT
Mnemonic REBOOT Severity Level 4
Recommended
No action is recommended.
Action
9.4 REBOOT
Mnemonic REBOOT Severity Level 4
Variable Fields $2: The date and time when this schedule is set.
$3: The date and time when the device will reboot on schedule.
Recommended
Don’t forget the time when the device will reboot.
Action
10 CSPF Messages
This section contains the entire system log messages related to CSPF.
10.1 LOG
Mnemonic LOG Severity Level 6
Recommended
No action is recommended.
Action
11 DEVM Messages
This section contains the entire system log messages related to DEVM.
11.1 BOARDREMOVE
Mnemonic BOARDREMOVE Severity Level 4
Recommended
No action is recommended.
Action
11.2 BOARDOK
Mnemonic BOARDOK Severity Level 4
Recommended
No action is recommended.
Action
11.3 BOARDFAULT
Mnemonic BOARDFAULT Severity Level 4
Recommended
No action is recommended.
Action
11.4 BOARDLOADING
Mnemonic BOARDLOADING Severity Level 4
Recommended
No action is recommended.
Action
11.5 CARDREMOVE
Mnemonic CARDREMOVE Severity Level 4
Recommended
No action is recommended.
Action
11.6 CARDINSERT
Mnemonic CARDINSERT Severity Level 4
Recommended
No action is recommended.
Action
11.7 CARDFAULT
Mnemonic CARDFAULT Severity Level 4
Recommended
No action is recommended.
Action
11.8 POWERRECOVER
Mnemonic POWERRECOVER Severity Level 4
Power 1 recovered.
Recommended
No action is recommended.
Action
11.9 MPOWERRECOVER
Mnemonic MPOWERRECOVER Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
11.10 SPOWERRECOVER
Mnemonic SPOWERRECOVER Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
11.11 POWERFAIL
Mnemonic POWERFAIL Severity Level 4
Recommended
No action is recommended.
Action
11.12 POWERABSENT
Mnemonic POWERABSENT Severity Level 5
Recommended
No action is recommended.
Action
11.13 FANRECOVER
Mnemonic FANRECOVER Severity Level 4
Trigger Action Insert the fan into its slot and wait.
Recommended
No action is recommended.
Action
11.14 FANFAIL
Mnemonic FANFAIL Severity Level 4
Recommended
No action is recommended.
Action
11.15 FANABSENT
Mnemonic FANABSENT Severity Level 4
Recommended
No action is recommended.
Action
11.16 TEMPOK
Hangzhou H3C Technologies Co., Ltd. 52/220
COMWARE System Log Message
Recommended
No action is recommended.
Action
11.17 TEMPLOW
Mnemonic TEMPLOW Severity Level 4
Trigger Action The board’s temperature changes to the range under the low limit
Recommended
No action is recommended.
Action
11.18 TEMPUP
Mnemonic TEMPUP Severity Level 4
Trigger Action The board’s temperature changes to the range over the up limit
Recommended
No action is recommended.
Action
11.19 RPSNORMAL
Mnemonic RPSNORMAL Severity Level 4
Recommended
No action is recommended.
Action
11.20 RPSABSENT
Mnemonic RPSABSENT Severity Level 4
Recommended
No action is recommended.
Action
11.21 CFINSERT
Mnemonic CFINSERT Severity Level 4
Recommended
No action is recommended.
Action
11.22 CFREMOVE
Mnemonic CFREMOVE Severity Level 4
Recommended
No action is recommended.
Action
11.23 SYSTEMREBOOT
Mnemonic SYSTEMREBOOT Severity Level 4
Recommended
No action is recommended.
Action
11.24 BOARDREBOOT
Mnemonic BOARDREBOOT Severity Level 4
Recommended
No action is recommended.
Action
11.25 SUBCARDREBOOT
Mnemonic SUBCARDREBOOT Severity Level 4
Recommended
No action is recommended.
Action
11.26 CURRENTNORMAL
Mnemonic CURRENTNORMAL Severity Level 4
Trigger Action Current between the upper limit and lower limit.
Recommended
No action is recommended.
Action
11.27 CURRENTSMALL
Mnemonic CURRENTSMALL Severity Level 4
Recommended
No action is recommended.
Action
11.28 CURRENTBIG
Mnemonic CURRENTBIG Severity Level 5
Recommended
No action is recommended.
Action
11.29 VOLTNORMAL
Mnemonic VOLTNORMAL Severity Level 4
Trigger Action Voltage between the upper limit and lower limit.
Recommended
No action is recommended.
Action
11.30 VOLTLOW
Mnemonic VOLTLOW Severity Level 4
Recommended
No action is recommended.
Action
11.31 VOLTHIGH
Mnemonic VOLTHIGH Severity Level 4
Recommended
No action is recommended.
Action
11.32 NOENOUGHMEM
Mnemonic NOENOUGHMEM Severity Level 4
Syslog Message IO Board [INTEGER] has not enough memory to load file.
Trigger Action There is not enough memory for the board loading file.
Recommended
No action is recommended.
Action
11.33 SAMEREQUEST
Mnemonic SAMEREQUEST Severity Level 4
Syslog Message IO Board [INTEGER] has a same request already, please try later.
Explanation As the board has a same request already, user should try later.
Recommended
No action is recommended.
Action
11.34 ABORTLOAD
Mnemonic ABORTLOAD Severity Level 4
Syslog Message The loading message of IO Board [INTEGER] timed out, abort load.
The loading message of the board timed out, and system abort the
Explanation
load.
Recommended
No action is recommended.
Action
11.35 REQUESTINVALID
Mnemonic REQUESTINVALID Severity Level 4
The loading request of the board is invalid, user should check the
Explanation
bootrom version.
Recommended
No action is recommended.
Action
11.36 LOADFAIL
Mnemonic LOADFAIL Severity Level 4
Syslog Message Board failed to load file in Frame [INTEGER] IO board [INTEGER].
Recommended
No action is recommended.
Action
11.37 LOADFINISH
Mnemonic LOADFINISH Severity Level 4
Recommended
No action is recommended.
Action
11.38 READFAIL
Mnemonic READFAIL Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
11.39 STARTSELF
Mnemonic STARTSELF Severity Level 4
Recommended
No action is recommended.
Action
11.40 CANNOTOPEN
Mnemonic CANNOTOPEN Severity Level 4
Syslog Message Cannot open the file, IO board [INTEGER] will request load again!
Explanation As cannot open the file, the board will request load again.
Recommended
No action is recommended.
Action
11.41 MANYRESENT
Mnemonic MANYRESENT Severity Level 4
As there are too many resent frames, the board will request load
Explanation
again.
Recommended
No action is recommended.
Action
11.42 MANYINVALID
Mnemonic MANYINVALID Severity Level 4
As the are too many invalid frames, the board will request load
Explanation
again.
Recommended
No action is recommended.
Action
11.43 CHECKSUMERR
Mnemonic CHECKSUMERR Severity Level 4
Syslog Message Checksum error, IO board [INTEGER] will request load again.
Recommended
No action is recommended.
Action
12 DHCP Messages
This section contains the entire system log messages related to DHCP.
12.1 DHCPC_LOCAL_SERVER
Mnemonic DHCPC_LOCAL_SERVER Severity Level 3
$2: The name of DHCP client interface from which the DHCP
packets are received.
Variable Fields
$3: The type of the received DHCP packet.
Recommended
No action is recommended.
Action
12.2 DHCPC_FSM_TO_HALT
$1: The name of DHCP client interface from which the DHCP
Variable Fields
packets are received.
Recommended
No action is recommended.
Action
12.3 DHCPC_BOOTP_ALLOC_FAIL
Mnemonic DHCPC_BOOTP_ALLOC_FAIL Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
13 DHCPR Messages
This section contains the entire system log messages related to DHCPR.
13.1 DHCPR_DETECT_SERVER
Mnemonic DHCPR_DETECT_SERVER Severity Level 4
Recommended
No action is recommended.
Action
14 DHCPS Messages
This section contains the entire system log messages related to DHCPS.
14.1 DHCPS_LOCAL_SERVER
Mnemonic DHCPS_LOCAL_SERVER Severity Level 4
$2: The name of DHCP server interface from which the DHCP
packets are received.
Variable Fields
$3: The type of the received DHCP packet.
Recommended
No action is recommended.
Action
15 DHCPSNOOP Messages
This section contains the entire system log messages related to DHCPSNOO.
15.1 dhcpsnoop_log
Mnemonic dhcpsnoop_log Severity Level 3
Recommended
No action is recommended.
Action
15.2 dhcpsnoop_log
Mnemonic dhcpsnoop_log Severity Level 3
Recommended
No action is recommended.
Action
15.3 dhcpsnoop_log
Mnemonic dhcpsnoop_log Severity Level 3
Trigger Action There is no enough resource for new rules on the interface.
Recommended
No action is recommended.
Action
15.4 dhcpsnoop_log
Mnemonic dhcpsnoop_log Severity Level 3
Recommended
No action is recommended.
Action
15.5 dhcpsnoop_log
Mnemonic dhcpsnoop_log Severity Level 3
Recommended
No action is recommended.
Action
16 DLDP Messages
This section contains the entire system log messages related to DLDP.
16.1 AuthenticationFailed
Mnemonic AuthenticationFailed Severity Level 2
Recommended
No action is recommended.
Action
16.2 UnidirectionalAuto
Mnemonic UnidirectionalAuto Severity Level 2
Recommended
Check the unidirectional link.
Action
16.3 UnidirectionalManual
Mnemonic UnidirectionalManual Severity Level 2
DLDP detects a unidirectional link and suggests that the port should
Explanation
be shutdown.
Recommended
Shutdown the port and check the unidirectional link.
Action
16.4 UnidirectionalAutoEnhance
Mnemonic UnidirectionalAutoEnhance Severity Level 2
In the enhance mode port [STRING] can not detect its aged out
neighbor. The transceiver has malfunction in TX direction or the
Syslog Message
misconnected link between local device and neighbour. The
shutdown mode is AUTO. DLDP shuts down the port.
UnidirectionalAutoEnhance:
Example In the enhance mode port GigabitEthernet1/3 can not detect its
aged out neighbor. The transceiver has malfunction in TX direction
or the misconnected link between local device and neighbour. The
shutdown mode is AUTO. DLDP shuts down the port.
Recommended
Check the unidirectional link.
Action
16.5 UnidirectionalManualEnhance
Mnemonic UnidirectionalManualEnhance Severity Level 2
In the enhance mode port [STRING] can not detect its aged out
neighbor. The transceiver has malfunction in TX direction or the
Syslog Message misconnected link between local device and neighbour. The
shutdown mode is MANUAL. The port needs to be shut down by the
user.
UnidirectionalManualEnhance:
Example In the enhance mode port GigabitEthernet1/3 can not detect its
aged out neighbor. The transceiver has malfunction in TX direction
or the misconnected link between local device and neighbour. The
shutdown mode is MANUAL. The port needs to be shut down by the
user.
Recommended
Shutdown the port and check the unidirectional link.
Action
17 DPURPF Messages
This section contains the entire system log messages related to DPURPF.
17.1 DPURPF
Mnemonic ATCKDF Severity Level 4
Recommended
Please check IP source address of the packets received by the device.
Action
18 ETHOAM Messages
This section contains the entire system log messages related to ETHOAM.
18.1 OAMENABLE
Mnemonicm OAMENABLE Severity Level 2
Recommended
No action is recommended.
Action
18.2 OAMDISABLE
Mnemonic OAMDISABLE Severity Level 2
Recommended
No action is recommended.
Action
18.3 OAMDISOK
Mnemonic OAMDISOK Severity Level 2
Both ports of a link must enable OAM protocol and at least one of
Trigger Action
them runs in active mode.
Recommended
No action is recommended.
Action
18.4 OAMDISFAIL
Syslog Message port [string] OAM connection failed, for remote unsatisfied.
Recommended
No action is recommended.
Action
18.5 OAMDISTIMEOUT
Mnemonic OAMDISTIMEOUT Severity Level 2
Syslog Message port [string] OAM connection failed, for discovery timed out.
Recommended
No action is recommended.
Action
18.6 OAMPORTDOWN
Mnemonic OAMPORTDOWN Severity Level 2
Syslog Message port [string] OAM connection failed, for port link Down.
Recommended
No action is recommended.
Action
18.7 EnUnderControl
Mnemonic EnUnderControl Severity Level 2
After partner OAM entity inputs command “oam loopback”, local OAM
Explanation
entity enters remote loopback as a controlled DTE
Recommended
No action is recommended.
Action
18.8 DisUnderControl
Mnemonic DisUnderControl Severity Level 2
After partner OAM entity inputs command “undo oam loopback”, local
Explanation
OAM entity quits remote loopback as a controlled DTE
Trigger Action Partner OAM entity inputs command “undo OAM loopback”
Recommended
No action is recommended.
Action
18.9 EnControl
Mnemonic EnControl Severity Level 2
After local OAM entity inputs command “oam loopback”, local OAM
Explanation
entity enters remote loopback as a controlling DTE
Recommended
No action is recommended.
Action
18.10 DisControl
Mnemonic DisControl Severity Level 2
After local OAM entity inputs command “undo OAM loopback”, local
Explanation
OAM entity quits remote Loopback as a controlling DTE
Trigger Action local OAM entity inputs command “undo oam loopback”
Recommended
No action is recommended.
Action
18.11 LoopbackExit
Mnemonic LoopbackExit Severity Level 2
Trigger Action link status is down or OAM entity as controlled DTE is disable
Recommended
No action is recommended.
Action
18.12 StateError
Mnemonic StateError Severity Level 2
Syslog Message OAM Port [string]: Remote loopback exits due to error status.
Recommended It is best for OAM entity to stop OAM protocol at once and running
Action OAM protocol over again.
18.13 LINKFAULT
Mnemonic LINKFAULT Severity Level 2
Recommended
Reconnect the receiver fiber of local port
Action
18.14 REMOTELINKFAULT
Recommended
Reconnect the receiver fiber of remote port
Action
18.15 LOCALERRFRAME
Mnemonic LOCALERRFRAME Severity Level 2
Recommended
Check the link
Action
18.16 REMOTEERRFRAME
Recommended
Check the link
Action
18.17 LOCALERRFRAMEPERIOD
Mnemonic LOCALERRFRAMEPERIOD Severity Level 2
Syslog Message \r\nLocal errored frame period event has occured on [string].
Recommended
Check the link
Action
18.18 REMOTEERRFRAMEPERIOD
Syslog Message \r\nRemote errored frame period event has occured on [string].
This event is generated if the errored frame count on the remote port
Trigger Action is equal to or greater than the specified threshold for a period.
Recommended
Check the link
Action
18.19 LOCALERRFRAMESEC
Mnemonic LOCALERRFRAMESEC Severity Level 2
Recommended
Check the link
Action
18.20 REMOTEERRFRAMESEC
Recommended
Check the link
Action
18.21 REMOTEDYINGGASP
Mnemonic REMOTEDYINGGASP Severity Level 2
Recommended
Don’t use this link until it returns to a normal condition
Action
18.22 REMOTECRITICALE
Recommended
Don’t use this link until it returns to a normal condition
Action
19 FIBV4 Messages
This section contains the entire system log messages related to FIBV4.
19.1 log_fib
Mnemonic log_fib Severity Level 5
Explanation The operation described is running. This log is used in main board.
Recommended
No action is recommended.
Action
19.2 log_fib
Mnemonic log_fib Severity Level 5
Recommended
No action is recommended.
Action
19.3 log_fib
Mnemonic log_fib Severity Level 4
$1: IP address
Variable Fields
$2: VrfIndex
The driver returns conflict flag when the host route entry has already
Explanation
been added.
If the driver returns conflict flag when the host route entry has
Trigger Action
already been added, the log is displayed.
Recommended
Modify configuration.
Action
19.4 Log_fib_MemShortage
Mnemonic Log_fib_MemShortage Severity Level 4
message!
Recommended
Please check the configuration and the situation.
Action
19.5 Log_fib_MemResume
Mnemonic Log_fib_MemResume Severity Level 4
Recommended
No action is recommended
Action
20 FILTER Messages
This section contains the entire system log messages related to FILTER
20.1 IPFILTER
Mnemonic IPFILTER Severity Level 4
Recommended
No action is recommended
Action
21.1 USERIN
Mnemonic USERIN Severity Level 4
FTP server accepts a FTP client request, and user name and
Trigger Action
password are correct.
Recommended
No action is recommended.
Action
21.2 USEROUT
Mnemonic USEROUT Severity Level 4
Trigger Action The user which logged in logs out from FTP server
Recommended
No action is recommended.
Action
21.3 USERIN
Mnemonic USERIN Severity Level 4
Recommended
No action is recommended.
Action
21.4 USERFAIL
Mnemonic USERFAIL Severity Level 4
Some errors occurr during FTP client put file to server or the space
Trigger Action
of disk of FTP server is not enough.
Recommended
No action is recommended.
Action
21.5 REQUEST
Mnemonic REQUEST Severity Level 5
Turn on the FTP server debugging, the FTP user input some
Trigger Action
commands.
Recommended
No action is recommended.
Action
21.6 SENDDATA
Turn on the ftp server debugging, the FTP user gets file
Trigger Action
successfully.
Recommended
No action is recommended.
Action
21.7 RECVDATA
Mnemonic RECVDATA Severity Level 5
Syslog Message FTP server receive [ULONG] bytes from client [string]([ipaddr])
Switch on the FTP server debugging, the FTP user put file
Trigger Action
successfully.
Recommended
No action is recommended.
Action
21.8 RUNERROR
Mnemonic RUNERROR Severity Level 4
Recommended
No action is recommended.
Action
22 GARP Messages
This section contains the entire system log messages related to GARP
Variable Fields
Trigger Action Receive a garp packet in which the protocol Id field is not 0x0001.
Recommended
No action is recommended.
Action
Variable Fields
Trigger Action Receive a gvrp packet in which attribute type field is wrong.
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Explanation Receive a gvrp packet but in which the attribute field is unknown.
Trigger Action When receive a gvrp packet in which the attribute field is unknown.
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
23 HA Messages
This section contains the entire system log messages related to HA.
23.1 LOG
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
Restart the Slave Board and download a new image
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Explanation Slave board in slot $1 is not ready, and the device will reboot.
Trigger Action Slave board in slot $1 is not ready, and the device will reboot.
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
24 HABP Messages
24.1 HABPSTART
Mnemonic HABPSTART Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
24.2 HABPSTOP
Mnemonic HABPSTOP Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
25 HTTPD Messages
This section contains the entire system log messages related to HTTPD .
25.1 Log
Mnemonic Log Severity Level 4
Explanation This is a common print info and output the parameter info.
Recommended
No action is recommended.
Action
26 HTTPS Messages
This section contains the entire system log messages related to HTTPS.
26.1 LOG
Mnemonic LOG Severity Level 4
Explanation This is a common print info and output the parameter info.
Recommended
No action is recommended.
Action
27 HWCM Messages
This section contains the entire system log messages related to HWCM.
27.1 EXIT
Mnemonic EXIT Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
27.2 TRAPLOG
Mnemonic TRAPLOG Severity Level 4
$1: OID
EventIndex=13,CommandSource=1,ConfigSource=3,ConfigDestinati
on=2
Recommended
No action is recommended.
Action
27.3 CCOPY
Mnemonic CCOPY Severity Level 4
Recommended
No action is recommended.
Action
28 IGMP Messages
28.1 INFO
Recommended
No action is recommended.
Action
28.2 ERR
Mnemonic ERR Severity Level 3
Recommended
No action is recommended.
Action
29 IFNET Messages
This section contains the entire system log messages related to IFNET.
29.1 PORTTAG
Mnemonic PORTTAG Severity Level 4
Recommended Clear all porttags allocated. Input “reset unused porttag” under the
Action user view.
29.2 UPDOWN
Mnemonic UPDOWN Severity Level 4
Recommended
No action is recommended.
Action
29.3 UPDOWN
Mnemonic UPDOWN Severity Level 4
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
This log message is generated when any type of the flux exceeds
Explanation its upper limit on a port without configuring “storm-constrain control
[block | shutdown ]”.
This log message is generated when any type of the flux exceeds
Trigger Action its upper limit on a port without configuring “storm-constrain control
[block | shutdown ]”.
This trap message is generated when any type of the flux exceeds
Explanation its upper limit on a port with configuring “storm-constrain control
[block | shutdown ]”.
This trap message is generated when any type of the flux exceeds
Trigger Action its upper limit on a port with configuring “storm-constrain control
[block | shutdown ]”.
30 IKE Messages
This section contains the entire system log messages related to IKE.
30.1 DROP
Mnemonic DROP Severity Level 4
IKE packet dropped: (src addr: [IPADDR], dst addr: [IPADDR]) with
Syslog Message I_Cookie [STRING] and R_Cookie [STRING], because of '
[STRING] ' from payload [STRING].
Example IKE packet dropped: (src addr: 1.0.0.2, dst addr: 1.0.0.1) with
I_Cookie 25f2c03c1ef46a5c and R_Cookie 7ae81223de52ab5d,
because of ' No IPSec policy found ' from payload PROPOSAL.
Recommended
No action is recommended.
Action
31 IPDBG Messages
31.1 IP Info
Mnemonic IP Info Severity Level 3
$1: Task ID
$4: Information
Recommended
No action is recommended.
Action
32 IPCIM Messages
This section contains the entire system log messages related to IP CIM.
32.1 ipcim_log
Mnemonic Ipcim_log Severity Level 4
Recommended
No action is recommended.
Action
33 IPsec Messages
This section contains the entire system log messages related to IPsec.
33.1 DROP
Mnemonic DROP Severity Level 4
Recommended
No action is recommended.
Action
34 IPV6FIBC Messages
This section contains the entire system log messages related to IPV6FIBC.
34.1 Log_fibc_MemShortage
Mnemonic Log_fibc_MemShortage Severity Level 4
%Feb608:55:26:1332007 SysName
Example IPV6FIBC/4/Log_fibc_MemShortage:Slot=3;
Recommended
Please check the configuration and the situation.
Action
34.2 Log_fibc_MemResume
Mnemonic Log_fibc_MemResume Severity Level 4
%Feb600:25:23:4952007 SysName
Example IPV6FIBC/4/Log_fibc_MemResume:Slot=3;
Recommended
No action is recommended
Action
35 IPV6PP Messages
This section contains the entire system log messages related to IPV6PP.
35.1 ReassError
Mnemonic ReassError Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
35.2 QueueFull
Mnemonic QueueFull Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
36 ISIS Messages
This section contains the entire system log messages related to ISIS.
36.1 ADJLOG
Hangzhou H3C Technologies Co., Ltd. 106/220
COMWARE System Log Message
Recommended
No action is recommended.
Action
37 L2TP Messages
This section contains the entire system log messages related to L2TP
37.1 CLVPDN1
Mnemonic CLVPDN1 Severity Level 6
Recommended
No action is recommended
Action
37.2 CLVPDN2
Mnemonic CLVPDN2 Severity Level 6
Recommended
No action is recommended
Action
38 L2V Messages
This section contains the entire system log messages related to L2V.
38.1 LOG
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
Check memory usage rate.
Action
Recommended
Check memory usage rate.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
Check encapsulation type.
Action
Recommended
Check the configuration of the remote CE ID and local CE ID.
Action
Recommended
Check the configuration of the remote CE ID and local CE ID.
Action
Trigger Action VSI receive unsupported ldp vpls mac withdraw message.
Recommended
No action is recommended.
Action
Recommended
Check the configuration of the remote CE ID and local CE ID.
Action
Trigger Action Same remote Site ID when insert RLB into VSI.
Recommended
Check the configuration of the remote CE ID and local CE ID.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
Check the configuration of CE connection.
Action
Recommended
Check the configuration of CE connection.
Action
Recommended
No action is recommended.
Action
39 L3VPN Messages
This section contains the entire system log messages related to L3VPN.
39.1 L3VPNLOG
Mnemonic L3VPNLOG Severity Level 1
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Trigger Action Create VPN instance, but failed to inform other module.
Recommended
No action is recommended.
Action
Trigger Action Delete VPN instance, but failed to inform other module.
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
40 LAGG Messages
This section contains the entire system log messages related to LAGG.
40.1 LAGG_LOG
Recommended
No action is recommended
Action
40.2 LAGG_LOG
Mnemonic LAGG_LOG Severity Level 2
Recommended
No action is recommended
Action
41 LDP Messages
This section contains the entire system log messages related to LDP.
41.1 SessionUp
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
41.2 SessionDown
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
41.3 LDP
Mnemonic LOG Severity Level 4
Recommended
No action is required.
Action
Recommended
No action is required.
Action
42 LLC2 Messages
Hangzhou H3C Technologies Co., Ltd. 114/220
COMWARE System Log Message
43 LLDP Messages
This section contains the entire system log messages related to LLDP.
43.1 CREREM
Mnemonic CREREM Severity Level 6
Recommended
No action is recommended.
Action
43.2 DELREM
Mnemonic DELREM Severity Level 6
Recommended
No action is recommended.
Action
43.3 AGEOUTREM
Mnemonic AGEOUTREM Severity Level 6
Trigger Action The port didn’t received message from the neighbour in time.
Recommended
No action is recommended.
Action
43.4 TOOMANGREM
Mnemonic TOOMANGREM Severity Level 6
Recommended
No action is recommended.
Action
43.5 NONTOOMANGREM
Mnemonic NONTOOMANGREM Severity Level 6
Recommended
No action is recommended.
Action
44 LS Messages
This section contains the entire system log messages related to LS.
44.1 CNAHGEPASSWORD
Mnemonic CNAHGEPASSWORD Severity Level 5
When user modify the password, record the reason that password
Explanation
will age out after n day
Recommended
No action is recommended.
Action
44.2 CNAHGEPASSWORD
Syslog Message [STRING] changed password for password has aged out
When user modify the password, record the reason that password
Explanation
has aged out
Recommended
No action is recommended.
Action
44.3 CNAHGEPASSWORD
Mnemonic CNAHGEPASSWORD Severity Level 5
Syslog Message [STRING] changed password for the password is too short
When user modify the password, record the reason that password
Explanation
is too short
Recommended
No action is recommended.
Action
44.4 CNAHGEPASSWORD
Mnemonic CNAHGEPASSWORD Severity Level 5
When user modify the password, record the reason that password
Explanation
composition is invalid
Recommended
No action is recommended.
Action
44.5 WRITEPASSTOFILE
Mnemonic WRITEPASSTOFILE Severity Level 5
Variable Fields
Recommended
No action is recommended.
Action
45 LSPM Messages
This section contains the entire system log messages related to LSPM.
45.1 LSPM
Mnemonic LSPM Severity Level 4
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
Recommended
No action is required.
Action
46 LWPS Messages
This section contains the entire system log messages related to LWPS.
46.1 LOG
Recommended
No action is required.
Action
46.2 LOG
Mnemonic LOG Severity Level 6
Explanation The AP failed to connect to AC, and the system can’t get AP name.
Recommended
No action is required.
Action
47 MCS Messages
This section contains the entire system log messages related to MCS.
47.1 LOG
Mnemonic LOG Severity Level 5
Recommended
No action is recommended.
Action
48 MFIB Messages
48.1 LOG
Mnemonic LOG Severity Level 5
$4: The number of the line in the file the warning comes from.
Recommended
No action is recommended.
Action
49 MLD Messages
This section contains the entire system log messages related to MLD.
49.1 ERROR
Mnemonic ERROR Severity Level 4
Recommended
No action is recommended.
Action
50.1 OAM_LOG_INFO
Mnemonic OAM_LOG_INFO Severity Level 4
$1:Ingress LSR ID
$2: Tunnel ID
rlsn down!
start detect!
stop detect!
This log records at the tunnel egress the fact that OAM detects
Explanation
status change.
Recommended
Check the status change reason and perform corresponding action.
Action
50.2 OAM_LOG_INFO
Mnemonic OAM_LOG_INFO Severity Level 4
rlsn up!
Variable Fields
rlsn down!
start detect!
stop detect!
This log records at the tunnel ingress the fact that OAM detects
Explanation
status change.
Recommended
Check the status change reason and perform corresponding action.
Action
51 QoS Messages
This section contains the entire system log messages related to QoS
51.1 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
51.2 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
51.3 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
51.4 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
51.5 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
51.6 warning
Mnemonic warning Severity Level 4
[STRING]
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
52.1 MACFULL
Mnemonic MACFULL Severity Level 4
Variable Fields
Trigger Action When the MAC address table is full, this log is dispayed.
Recommended
No action is recommended.
Action
53 MRM Messages
53.1 MRM
Mnemonic LOG Severity Level 4
$5: The number of the line in the file the warning comes from.
Recommended
No action is recommended.
Action
54 MSDP Messages
54.1 PEER_UP
$4: The number of the line in the file the warning comes from.
Recommended
No action is recommended.
Action
54.2 PEER_DOWN
Mnemonic PEER_UPDOWN Severity Level 4
$4: The number of the line in the file the warning comes from..
Recommended
No action is recommended.
Action
54.3 SA_LIMIT
$8: The number of the line in the file the warning comes from..
Recommended
No action is recommended.
Action
54.4 PEER_ACCEPT
$5: The number of the line in the file the warning comes from..
Recommended
No action is recommended.
Action
55 MSTP Messages
This section contains the entire system log messages related to MSTP.
55.1 STPSTART
Mnemonic STPSTART Severity Level 2
Variable Fields
Recommended
No action is recommended
Action
55.2 STPSTOP
Mnemonic STPSTOP Severity Level 2
Variable Fields
the device.
Recommended
No action is recommended
Action
55.3 ROOT
Mnemonic ROOT Severity Level 2
Syslog Message ROOT: We are not the root switch of the instance [ULONG]!,
55.4 IVBPDU
Mnemonic IVBPDU Severity Level 2
Recommended Ensure the network connection and configuration are correct. The
Action remote port should not send STP packets.
55.5 RGSUP
Hangzhou H3C Technologies Co., Ltd. 133/220
COMWARE System Log Message
$ 1 Instance Identify
Variable Fields
$ 2 Interface name
55.6 LGEXP
Mnemonic LGEXP Severity Level 2
$ 1 Instance Identify
Variable Fields
$ 2 Port name
Recommended Ensure the lines are normal (optical fiber are bidirectional through),
Action and the uplink STP port is not disabled.
55.7 BPDUFORMATERROR
Mnemonic BPDUFORMATERROR Severity Level 2
Recommended Configure the format of the BPDU packets sent from the connected
Action device the same as the local port, and restore the port to up state.
55.8 BPDUFORMATCONFIGERROR
Mnemonic BPDUFORMATCONFIGERROR Severity Level 2
Recommended Configure the format of the BPDU packets sent from the connected
Action device the same as the local port.
55.9 BPDUFORMATCONFIGRIGHT
Mnemonic BPDUFORMATCONFIGRIGHT Severity Level 2
Recommended
No action is recommended.
Action
55.10 BPDURCVDEXPIRY
Hangzhou H3C Technologies Co., Ltd. 135/220
COMWARE System Log Message
$1:The instance-id
Variable Fields
$2:The port name
(1) concentrated:
Recommended
Prolong the hello packet timeout time.
Action
56 NATPT Messages
This section contains the entire system log messages related to NATPT.
56.1 TRANS
Mnemonic TRANS Severity Level 6
Trigger Action No
Recommended
No action is recommended.
Action
56.2 TRANS
Hangzhou H3C Technologies Co., Ltd. 136/220
COMWARE System Log Message
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
57 ND Messages
This section contains the entire system log messages related to ND.
57.1 ConfigConflict
Mnemonic ConfigConflict Severity Level 4
Syslog Message The same neighbor entry has been added on the interface [string]
The neighbor entry with same global IP address has been added
Explanation
into another interface
Recommended
No action is recommended.
Action
57.2 ConfigConflict
Mnemonic ConfigConflict Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
57.3 ConfigConflict
Mnemonic ConfigConflict Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
57.4 ConfigConflict
Mnemonic ConfigConflict Severity Level 4
Recommended
A different address should be configured
Action
57.5 ConfigConflict
Mnemonic ConfigConflict Severity Level 4
Recommended
A different value should be configured
Action
57.6 TimeError
Mnemonic TimeError Severity Level 3
Syslog Message Preferred lifetime is greater than the valid lifetime, Prefix: [ipaddr].
The preferred lifetime is greater than the valid lifetime in the prefix
Explanation information of RA received when address autoconfiguration is
enabled.
Recommended
No action is recommended.
Action
58 NDP Messages
58.1 NDPSTART
Mnemonic NDPSTART Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
59 NETSTREAM Messages
This section contains the entire system log messages related to NetStream.
59.1 MALLOC_FAIL
Mnemonic MALLOC_FAIL Severity Level 4
Recommended
No action is recommended.
Action
59.2 FREE_FAIL
Mnemonic MALLOC_FAIL Severity Level 4
Recommended
No action is recommended.
Action
59.3 NDPSTOP
Mnemonic NDPSTOP Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
60 NTDP Messages
60.1 NTDPSTART
Mnemonic NTDPSTART Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
60.2 NTDPSTOP
Mnemonic NTDPSTOP Severity Level 5
Variable Fields
Recommended
No action is recommended.
Action
61 NTP Messages
This section contains the entire system log messages related to NTP.
61.1 NTP_LOG
Mnemonic NTP_LOG Severity Level 4
Recommended
No action is recommended.
Action
62 OAM Messages
This section contains the entire system log messages related to OAM.
62.1 LOCALERRFRAME
Mnemonic LOCALERRFRAME Severity Level 2
Recommended
Check the link
Action
62.2 REMOTEERRFRAME
Mnemonic REMOTEERRFRAME Severity Level 2
Recommended
Check the link
Action
62.3 LOCALERRFRAMEPERIOD
Mnemonic LOCALERRFRAMEPERIOD Severity Level 2
Syslog Message \r\nLocal errored frame period event has occured on [string].
Recommended
Check the link
Action
62.4 REMOTEERRFRAMEPERIOD
Mnemonic REMOTEERRFRAMEPERIOD Severity Level 2
Syslog Message \r\nRemote errored frame period event has occured on [string].
This event is generated if the errored frame count on the remote port
Trigger Action is equal to or greater than the specified threshold for a period.
Recommended
Check the link
Action
62.5 LOCALERRFRAMESEC
Mnemonic LOCALERRFRAMESEC Severity Level 2
Recommended
Check the link
Action
62.6 REMOTEERRFRAMESEC
Recommended
Check the link
Action
62.7 REMOTEDYINGGASP
Mnemonic REMOTEDYINGGASP Severity Level 2
Recommended
Don’t use this link until it returns to a normal condition
Action
62.8 REMOTECRITICALE
Recommended
Don’t use this link until it returns to a normal condition
Action
63 OPTMOD Messages
This section contains the entire system log messages related to OPTMOD.
63.1 BIAS_HIGH
Mnemonic BIAS_HIGH Severity Level 2
Recommended
Check the module or replace it.
Action
63.2 TX_POW_HIGH
Mnemonic TX_POW_HIGH Severity Level 2
Recommended
Check the module or replace it.
Action
63.3 TYPE_ERR
Mnemonic TYPE_ERR Severity Level 3
Syslog Message [STRING] : The transceiver type is not supported by port hardware!
Recommended
Check the module or replace it.
Action
63.4 CFG_ERR
Mnemonic CFG_ERR Severity Level 3
Syslog Message [STRING] : The transceiver type does not match port configuration!
Recommended
Check the module or replace it.
Action
63.5 MODULE_OUT
Hangzhou H3C Technologies Co., Ltd. 147/220
COMWARE System Log Message
Trigger Action The module on this port has beed plugged out.
Recommended
None
Action
63.6 MODULE_IN
Mnemonic MODULE_IN Severity Level 4
Recommended
None
Action
63.7 IO_ERR
Mnemonic IO_ERR Severity Level 5
Recommended
Check the module or replace it.
Action
63.8 CHKSUM_ERR
Mnemonic CHKSUM_ERR Severity Level 5
Recommended
Check the module or replace it.
Action
63.9 TX_ALM_ON
Mnemonic TX_ALM_ON Severity Level 5
Recommended
Check the module or replace it.
Action
63.10 TX_ALM_OFF
Mnemonic TX_ALM_OFF Severity Level 5
Recommended
None
Action
63.11 RX_ALM_ON
Mnemonic RX_ALM_ON Severity Level 5
Recommended
Check the module or replace it.
Action
63.12 RX_ALM_OFF
Mnemonic RX_ALM_OFF Severity Level 5
Recommended
None
Action
63.13 MOD_ALM_ON
Mnemonic MOD_ALM_ON Severity Level 5
Recommended
Check the module or replace it.
Action
63.14 MOD_ALM_OFF
Mnemonic MOD_ALM_OFF Severity Level 5
Recommended
None
Action
63.15 TEMP_HIGH
Mnemonic TEMP_HIGH Severity Level 5
Recommended
None
Action
63.16 TEMP_LOW
Mnemonic TEMP_LOW Severity Level 5
Recommended
None
Action
63.17 TEMP_NORMAL
Mnemonic TEMP_NORMAL Severity Level 5
Recommended
None
Action
63.18 VOLT_HIGH
Mnemonic VOLT_HIGH Severity Level 5
Recommended
None
Action
63.19 VOLT_LOW
Mnemonic VOLT_LOW Severity Level 5
Recommended
None
Action
63.20 VOLT_NORMAL
Mnemonic VOLT_NORMAL Severity Level 5
Recommended
None
Action
63.21 RX_POW_HIGH
Mnemonic RX_POW_HIGH Severity Level 5
Recommended
None
Action
63.22 RX_POW_LOW
Mnemonic RX_POW_LOW Severity Level 5
Recommended
None
Action
63.23 RX_POW_NORMAL
Mnemonic RX_POW_NORMAL Severity Level 5
Recommended
None
Action
63.24 BIAS_LOW
Mnemonic BIAS_LOW Severity Level 5
Recommended
None
Action
63.25 BIAS_NORMAL
Mnemonic BIAS_NORMAL Severity Level 5
Recommended
None
Action
63.26 TX_POW_LOW
Recommended
None
Action
63.27 TX_POW_NORMAL
Mnemonic TX_POW_NORMAL Severity Level 5
Recommended
None
Action
63.28 PHONY_MODULE
Mnemonic PHONY_MODULE Severity Level 4
Recommended
None
Action
64 PBR6 Messages
This section contains the entire system log messages related to PBR6.
64.1 PBR6_LOG
Mnemonic PBR6_LOG Severity Level 4
Variable Fields
Recommended
No action is recommended.
Action
Variable Fields
Recommended
No action is recommended.
Action
65 PIM Messages
Hangzhou H3C Technologies Co., Ltd. 157/220
COMWARE System Log Message
This section contains the entire system log messages related to PIM.
65.1 INFO
Mnemonic INFO Severity Level 5
Recommended
No action is recommended.
Action
65.2 ERR
Mnemonic ERR Severity Level 4
Recommended
No action is recommended.
Action
66 PKEY Messages
This section contains the entire system log messages related to PKEY.
66.1 KEY_GENERATE
Mnemonic KEY_GENERATE Severity Level 4
Syslog
The public host key has been Created successfully.
Message
Variable Fields
Trigger Action The public host key has been Created successfully.
Recommended
No action is recommended.
Action
66.2 KEY_GENERATE
Mnemonic KEY_GENERATE Severity Level 4
Syslog
The public server key has been Created successfully.
Message
Variable Fields
Trigger Action The public server key has been Created successfully.
Recommended
No action is recommended.
Action
66.3 KEY_GENERATE
Mnemonic KEY_GENERATE Severity Level 4
Syslog
Failed to create public key pair.
Message
Variable Fields
Recommended
No action is recommended.
Action
66.4 KEY_ZEROIZE
Syslog
The public host key has been destroyed successfully.
Message
Variable Fields
Trigger Action The public host key has been destroyed successfully.
Recommended
No action is recommended.
Action
66.5 KEY_ZEROIZE
Mnemonic KEY_ZEROIZE Severity Level 4
Syslog
The public server key has been destroyed successfully.
Message
Variable Fields
Trigger Action The public server key has been destroyed successfully.
Recommended
No action is recommended.
Action
66.6 KEY_ZEROIZE
Mnemonic KEY_ZEROIZE Severity Level 4
Syslog
Failed to destroy the public key pair.
Message
Variable Fields
Recommended
No action is recommended.
Action
66.7 KEY_EXPORT
Mnemonic KEY_EXPORT Severity Level 4
Syslog
The public key has been exported to file successfully.
Message
Variable Fields
Trigger Action The public key has been exported to file successfully.
Recommended
No action is recommended.
Action
66.8 KEY_EXPORT
Mnemonic KEY_EXPORT Severity Level 4
Syslog
Failed to export the public key to file.
Message
Variable Fields
Recommended
No action is recommended.
Action
66.9 KEY_BACKUP
Mnemonic KEY_BACKUP Severity Level 3
Syslog
Failed to backup the public host key.
Message
Variable Fields
Recommended
No action is recommended.
Action
66.10 KEY_BACKUP
Mnemonic KEY_BACKUP Severity Level 3
Syslog
Failed to backup the public server key.
Message
Variable Fields
Recommended
No action is recommended.
Action
67 PKI Messages
This section contains the entire system log messages related to PKI.
67.1 Local_Cert_Retrieval
Mnemonic Local_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.2 Local_Cert_Retrieval
Mnemonic Local_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.3 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.4 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.5 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.6 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.7 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.8 CA_Cert_Retrieval
Mnemonic CA_Cert_Retrieval Severity Level 4
Recommended
No action is recommended.
Action
67.9 Local_Cert_Request
Mnemonic Local_Cert_Request Severity Level 4
Recommended
No action is recommended.
Action
67.10 Local_Cert_Request
Mnemonic Local_Cert_Request Severity Level 4
Recommended
No action is recommended.
Action
67.11 Local_Cert_Request
Mnemonic Local_Cert_Request Severity Level 4
Recommended
No action is recommended.
Action
67.12 Import_Cert_File
Mnemonic Import_Cert_File Severity Level 4
Recommended
No action is recommended.
Action
67.13 Import_Local_Cert
Mnemonic Import_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.14 Import_Local_Cert
Mnemonic Import_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.15 Import_Local_Cert
Mnemonic Import_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.16 Import_Local_Cert
Mnemonic Import_Local_Cert Severity Level 4
Syslog Message Failed to import domain [String] local certificate, no certificate in file.
Recommended
No action is recommended.
Action
67.17 Import_Local_Cert
Mnemonic Import_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.18 Import_Local_Key
Mnemonic Import_Local_Key Severity Level 4
Syslog Message Import local private key of the domain [String] successfully.
Recommended
No action is recommended.
Action
67.19 Import_Local_Key
Mnemonic Import_Local_Key Severity Level 4
Syslog Message Failed to import local private key of the domain [String].
Recommended
No action is recommended.
Action
67.20 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.21 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.22 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.23 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.24 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.25 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.26 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.27 Import_CA_Cert
Mnemonic Import_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.28 Update_CA_Cert
Mnemonic Update_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.29 Update_CA_Cert
Recommended
No action is recommended.
Action
67.30 Delete_CA_Cert
Mnemonic Delete_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.31 Delete_CA_Cert
Mnemonic Delete_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.32 Delete_CA_Cert
Mnemonic Delete_CA_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.33 Delete_Local_Cert
Mnemonic Delete_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.34 Delete_Local_Cert
Mnemonic Delete_Local_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.35 Verify_Cert
Mnemonic Verify_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.36 Verify_Cert
Mnemonic Verify_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.37 Verify_CA_Root_Cert
Mnemonic Verify_CA_Root_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.38 Verify_CA_Root_Cert
Mnemonic Verify_CA_Root_Cert Severity Level 4
Recommended
No action is recommended.
Action
67.39 Retrieval_CRL
Mnemonic Retrieval_CRL Severity Level 4
Recommended
No action is recommended.
Action
67.40 Retrieval_CRL
Mnemonic Retrieval_CRL Severity Level 4
Recommended
No action is recommended.
Action
67.41 Update_CRL
Mnemonic Update_CRL Severity Level 4
Recommended
No action is recommended.
Action
67.42 Update_CRL
Mnemonic Update_CRL Severity Level 4
Recommended
No action is recommended.
Action
67.43 Update_CRL
Mnemonic Update_CRL Severity Level 4
68 PORTAL Messages
This section contains the entire system log messages related to PORTAL.
68.1 PORTAL_LOG
Mnemonic PORTAL_LOG Severity Level 4
Recommended
No action is recommended.
Action
68.2 PORTAL_LOG
Mnemonic PORTAL_LOG Severity Level 4
Recommended
No action is recommended.
Action
68.3 PORTAL_LOG
Hangzhou H3C Technologies Co., Ltd. 178/220
COMWARE System Log Message
Recommended
No action is recommended.
Action
68.4 PORTAL_LOG
Mnemonic PORTAL_LOG Severity Level 4
Trigger Action Cannot get packets number for TCP cheat or the queue is full.
Recommended
No action is recommended.
Action
68.5 PORTAL_LOG
Mnemonic PORTAL_LOG Severity Level 5
Recommended
No action is recommended.
Action
69 Q921 Messages
Hangzhou H3C Technologies Co., Ltd. 179/220
COMWARE System Log Message
This section contains the entire system log messages related to Q921.
69.1 Q921_Log
Mnemonic Q921_Log Severity Level 8
$1: Uport
Variable Fields
$2: the occurred error type.
Recommended
No action is recommended.
Action
70 RDS Messages
This section contains the entire system log messages related to RDS.
70.1 LOGIN
Mnemonic LOGIN Severity Level 6
Recommended
No action is recommended.
Action
70.2 LOGIN
Mnemonic LOGIN Severity Level 6
Recommended
No action is recommended.
Action
70.3 LOGIN
Mnemonic LOGIN Severity Level 6
Recommended
No action is recommended.
Action
70.4 LOGIN
Hangzhou H3C Technologies Co., Ltd. 181/220
COMWARE System Log Message
Recommended
No action is recommended.
Action
71 RM Messages
This section contains the entire system log messages related to RM.
71.1 RMLOG
Mnemonic RMLOG Severity Level 4
$1:[STRING]
Variable Fields
$2:[STRING]
Recommended
No action is recommended.
Action
72 RMON Messages
This section contains the entire system log messages related to RMON.
72.1 ADDINFO
Mnemonic ADDINFO Severity Level 6
Variable Fields $2: An index that uniquely identifies an entry in the alarm table.
Explanation A new entry has been added into alarm table successfully.
Recommended
No action is recommended.
Action
72.2 DELINFO
Mnemonic DELINFO Severity Level 6
Variable Fields $2: An index that uniquely identifies an entry in the alarm table.
Recommended
No action is recommended.
Action
73 RMX Messages
This section contains the entire system log messages related to RMX.
73.1 LOG
Hangzhou H3C Technologies Co., Ltd. 183/220
COMWARE System Log Message
$1:[STRING]
Variable Fields
$2:[STRING]
Recommended
No action is recommended.
Action
74 RPR Messages
This section contains the entire system log messages related to RPR.
74.1 TOPOINCONS
Mnemonic TOPOINCONS Severity Level 3
Recommended
No action is recommended.
Action
74.2 TOPOINCONSOVER
Mnemonic TOPOINCONSOVER Severity Level 3
Recommended
No action is recommended.
Action
74.3 TOPOINSTAB
Mnemonic TOPOINSTAB Severity Level 3
Recommended
No action is recommended.
Action
74.4 TOPOINSTABOVER
Mnemonic TOPOINSTABOVER Severity Level 3
Recommended
No action is recommended.
Action
74.5 STATNUMEXCED
Mnemonic STATNUMEXCED Severity Level 3
Explanation The number of stations on the RPR ring exceeded the maximum.
Trigger Action The number of stations on the RPR ring exceeded the maximum.
Recommended
Disconnect the station that exceeded the maximum.
Action
74.6 STATNUMEXCEEDOVER
Mnemonic STATNUMEXCEEDOVER Severity Level 3
When the number of stations on the RPR decreases to less than the
Trigger Action
maximum.
Recommended
No action is recommended.
Action
74.7 MACDUP
Mnemonic MACDUP Severity Level 3
More than two stations on the RPR ring have the same MAC
Explanation
address.
Trigger Action Two stations on the RPR ring have the same MAC address.
Recommended Finding the stations that have same MAC address with others, and
Action changing their MAC addresses.
74.8 MACDUPOVER
Hangzhou H3C Technologies Co., Ltd. 186/220
COMWARE System Log Message
Trigger Action The stations with same mac address changed their mac address.
Recommended
No action is recommended.
Action
74.9 IPDUP
Mnemonic IPDUP Severity Level 3
Explanation More than two stations on the RPR ring have the same IP address.
Trigger Action Two stations on the RPR ring have the same IP address.
Recommended Finding the station that have same IP address with others, and
Action changing their IP addresses.
74.10 IPDUPOVER
Mnemonic IPDUPOVER Severity Level 3
Explanation No more stations on the RPR ring has the same IP address.
Recommended
No action is recommended.
Action
74.11 LRTTINCOMP
Mnemonic LRTTINCOMP Severity Level 3
Recommended
No action is recommended.
Action
74.12 LRTTINCOMPOVER
Mnemonic LRTTINCOMPOVER Severity Level 3
Recommended
No action is recommended.
Action
74.13 PROTINCONS
Mnemonic PROTINCONS Severity Level 3
More than two stations on the RPR ring with the diffirent protection
Explanation
configuration
Recommended
Configure all the stations on the ring with same protection mode.
Action
74.14 PROTINCONSOVER
Mnemonic PROTINCONSOVER Severity Level 3
Recommended
No action is recommended.
Action
74.15 JBINCONS
Mnemonic JBINCONS Severity Level 3
More than two stations on the RPR ring with the diffirent jumbo
Explanation
preference configurations
Two stations on the RPR ring with the diffirent jumbo preference
Trigger Action
configurations.
Recommended Config all the stations on the ring with same jumbo preference
Action mode.
74.16 JBINCONSOVER
Mnemonic JBINCONSOVER Severity Level 3
No more station on the RPR ring with the diffirent jumbo preference
Explanation
configurations.
All the stations on the ring configed their jumbo preference to the
Trigger Action
same.
Recommended
No action is recommended.
Action
74.17 RESERBWEXCEED
Mnemonic RESERBWEXCEED Severity Level 3
74.18 RESERBWEXCEEDOVER
Mnemonic JBINCONSOVER Severity Level 3
Recommended
No action is recommended.
Action
74.19 MISCABLING
Mnemonic MISCABLING Severity Level 3
Recommended Finding the station that connects its west/ease span to another
Action station’s west/east, and connects reverse span. .
74.20 MISCABLINGOVER
Mnemonic MISCABLINGOVER Severity Level 3
Recommended
No action is recommended.
Action
74.21 IDLEISOLATE
Mnemonic IDLEISOLATE Severity Level 3
A station is in idle isolate state while its west span connects to its
Explanation
east
Trigger Action While a station’s west span connect to its east span
Recommended
No action is recommended.
Action
74.22 IDLEISOLATEOVER
Mnemonic IDLEISOLATEOVER Severity Level 3
A station exit Idle isolate state when its west span disconnects to its
Explanation
east
Trigger Action When the station’s west span disconnect to its east.
Recommended
No action is recommended.
Action
75 RRPP Messages
This section contains the entire system log messages related to RRPP.
75.1 FAIL
Mnemonic FAIL Severity Level 2
Trigger Action Link status of devices on this RRPP ring changed down.
75.2 RESTORE
Recommended
No action is recommended
Action
76 RSVP Messages
This section contains the entire system log messages related to RSVP.
76.1 RSVP_LOG_INFO
Mnemonic RSVP_LOG_INFO Severity Level 6
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
77 SHELL Messages
Hangzhou H3C Technologies Co., Ltd. 193/220
COMWARE System Log Message
This section contains the entire system log messages related to SHELL.
77.1 LOGIN
Mnemonic EXIT Severity Level 4
Recommended
No action is recommended.
Action
77.2 LOGOUT
Mnemonic EXIT Severity Level 4
Recommended
No action is recommended.
Action
77.3 CLI
Mnemonic CLI Severity Level 5
Recommended
No action is recommended.
Action
77.4 CMD
Mnemonic CMD Severity Level 4
Recommended
No action is recommended.
Action
77.5 LOGINFAIL
Mnemonic LOGINFAIL Severity Level 4
Recommended
No action is recommended.
Action
78 SNMP Messages
This section contains the entire system log messages related to SNMP.
78.1 GET
Mnemonic GET Severity Level 6
Explanation Record the information about the SNMP get request packet
NMS send the get request and the SNMP recording get operation,
Trigger Action
log function is enabled
Recommended
No action is recommended.
Action
78.2 SET
Explanation Record the information about set request and response packet
NMS send the set request and the SNMP recording set operation
Trigger Action
log function is enabled
Recommended
No action is recommended.
Action
79 SOCKET Messages
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
79.3 SOCKETLOG
Mnemonic SOCKETLOG Severity Level 4
Explanation There is something wrong when a task get its Task Control Block.
Some Task has forgot to release its Task Control Block When it kill
Trigger Action
itself.
Recommended
No action is recommended.
Action
80 SSH Messages
This section contains the entire system log messages related to ssh.
80.1 ACCEPTFAIL
Trigger Action Something wrong in socket module or the port of listening is in use.
Recommended
No action is recommended.
Action
80.2 LOGOUT
Mnemonic LOGOUT Severity Level 4
Recommended
No action is recommended.
Action
80.3 LOGIN
Mnemonic LOGIN Severity Level 4
Recommended
No action is recommended.
Action
80.4 LOGINFAIL
Mnemonic LOGINFAIL Severity Level 4
Recommended
No action is recommended.
Action
80.5 LOGINFAIL
Mnemonic LOGINFAIL Severity Level 4
[string] user [string] (IP:[string]) login failed because: The user don't
Syslog Message
support SFTP!
Explanation SSH user failed to login because user does not support SFTP.
Trigger Action SSH user failed to login because user does not support SFTP.
Recommended
No action is recommended.
Action
80.6 LOGINFAIL
Mnemonic LOGINFAIL Severity Level 4
[string] user [string] (IP:[string]) login failed because: The user don't
Syslog Message
support STEL!
Explanation SSH user failed to login because user does not support STEL.
Trigger Action SSH user failed to login because user does not support STEL.
Recommended
No action is recommended.
Action
80.7 AUTHFAIL
Mnemonic AUTHFAIL Severity Level 4
Recommended
No action is recommended.
Action
80.8 AUTHSUCC
Mnemonic AUTHSUCC Severity Level 4
Recommended
No action is recommended.
Action
80.9 LOGOUT
Mnemonic LOGOUT Severity Level 4
Recommended
No action is recommended.
Action
80.10 SFTPOPER
Mnemonic SFTPOPER Severity Level 4
Recommended
No action is recommended.
Action
81.1 TFTP_LOG
Mnemonic TFTP_LOG Severity Level 4
Explanation This is a common print info and output the parameter info.
Recommended
No action is recommended.
Action
82 TNLM Messages
This section contains the entire system log messages related to TNLM.
82.1 LOG
Mnemonic LOG Severity Level 4
Recommended
Check memory usage rate.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
No action is recommended.
Action
Recommended
Check memory usage rate.
Action
Recommended
Check memory usage rate.
Action
83 TUNNEL Messages
This section contains the entire system log messages related to TUNNEL.
83.1 NOTICE
Mnemonic NOTICE Severity Level 2
The IP address of the tunnel source interface is the same with that
Explanation of the destination of tunnel, which causes address conflict. You
must configure different addresses for them.
The IP address of the tunnel source interface is the same with that
Trigger Action
of the destination of tunnel.
Recommended
Modify the IP address of the tunnel source interface.
Action
83.2 NOTICE
Mnemonic NOTICE Severity Level 2
83.3 WARNING
Mnemonic WARNING Severity Level 4
Variable Fields No
Trigger Action The device driver has no enough resources when creating tunnel.
Recommended
No action is recommended.
Action
84 UDPH
84.1 UDPH_LOG
Mnemonic UDPH_LOG Severity Level 4
Explanation This is a common print info and output the parameter info.
Recommended
No action is recommended.
Action
85 USERLOG Messages
This section contains the entire system log messages related to USERLOG.
85.1 NAT
protocol;
source address;
NAT address;
Variable Fields destination address;
the time at which NAT session is deleted,or the time at which NAT
log is sent;
NAT log is enabled and configure that NAT log is export to info-
Trigger Action
center.
Recommended
No action is recommended.
Action
85.2 FLOW1.0
protocol;
source address;
source port;
destination port;
Example
Recommended
No action is recommended.
Action
85.3 FLOW3.0
protocol;
source address;
source port;
destination address;
destination port;
source VPN ID
destination VPN ID
Example
Recommended
No action is recommended.
Action
86 VFS Messages
This section contains the entire system log messages related to VFS.
86.1 LOG
Recommended
No action is recommended.
Action
86.2 LOG
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
86.3 LOG
Recommended
No action is recommended.
Action
86.4 LOG
Mnemonic LOG Severity Level 4
Recommended
No action is recommended.
Action
87 VMIB Messages
This section contains the entire system log messages related to VMIB.
Variable Fields NA
Recommended
Check the configuration of user and password.
Action
Variable Fields NA
Recommended
Check the configuration of SIP-ID and Password.
Action
Variable Fields NA
Recommended
No action is recommended.
Action
88 VOS Messages
This section contains the entire system log messages related to VOS.
88.1 ASSERT
Mnemonic ASSERT Severity Level 4
%2000-04-26 12:00:13-VOS-ASSERT:slot:0,Task:INTR(TID:-1)
Call Stack:
Recommended
No action is recommended.
Action
89 VRFFIB Messages
This section contains the entire system log messages related to VRFFIB.
89.1 log_vrffib
Mnemonic log_vrffib Severity Level 5
Explanation The operation described is running. This log is used in main board.
Recommended
No action is recommended.
Action
89.2 log_vrffib
Mnemonic log_vrffib Severity Level 5
Recommended
No action is recommended.
Action
89.3 log_vrffib
Mnemonic log_vrffib Severity Level 4
$1: IP address
Variable Fields
$2: VrfIndex
The driver returns conflict flag when the private host route entry is
Explanation
added.
If the driver returns conflict flag when the private host route entry is
Trigger Action
added, the log is displayed.
Recommended
Modify configuration.
Action
90 VRRP Messages
Hangzhou H3C Technologies Co., Ltd. 215/220
COMWARE System Log Message
This section contains the entire system log messages related to VRRP
90.1 LogAuthFailed
Mnemonic LogAuthFailed Severity Level 3
Variable Fields $2: The interface name which the vritual router was configed to.
90.2 PacketError
Mnemonic PacketError Severity Level 3
Trigger Action The version of the VRRP protocol is not the same as the system.
Recommended
See above
Action
90.3 ConfigError
Mnemonic ConfigError Severity Level 3
There are more than one IP Owners in the virtual router group.
Recommended
See above.
Action
90.4 MasterChange
$2: The interface name which the virtual router was configured to.
Variable Fields
$3: The Virtual Router’s ID.
Recommended
Check the status of the Virtual Router, make sure it works well.
Action
Recommended
See above.
Action
90.5 SetDriver
Mnemonic SetDriver Severity Level 3
Recommended
No action is recommended.
Action
90.6 SetDriver
Mnemonic SetDriver Severity Level 3
Variable Fields
Recommended
No action is recommended.
Action
90.7 TrapBecomeNewMaster
Mnemonic TrapBecomeNewMaster Severity Level 3
Recommended
No action is recommended.
Action
90.8 TrapAuthFailed
Mnemonic TrapAuthFailed Severity Level 3