You are on page 1of 8

Viewguard Motion detctors

PIR and DUAL detectors


Passive infrared sensor
Passive infrared and microwave sensor

Viewguard
DUAL
Viewguard
DUAL AM
Viewguard
PIR
Viewguard
PIR AM

Variations PIR detectors:


Variations DUAL detectors:
- Viewguard PIR AM BUS-2/BUS-1
VdS Class C - Viewguard DUAL AM BUS-2/BUS-1
EN 50131-1 and EN 50131-2-2, grade 3 VdS Class C
SES-EMA-RL-T2:2010-08 EN 50131-1 and EN 50131-2-4, grade 3
SES-EMA-RL-T2:2010-08
- Viewguard PIR BUS-2/BUS-1
VdS Class B - Viewguard DUAL BUS-2/BUS-1
EN 50131-1 and EN 50131-2-2, grade 2 VdS Class B
SES-EMA-RL-T2:2010-08 EN 50131-1 and EN 50131-2-4, grade 2
SES-EMA-RL-T2:2010-08
- Viewguard PIR AM FAI
VdS Class C - Viewguard DUAL AM FAI
EN 50131-1 and EN 50131-2-2, grade 3 VdS Class C
SES-EMA-RL-T2:2010-08 EN 50131-1 and EN 50131-2-4, grade 3
SES-EMA-RL-T2:2010-08
- Viewguard PIR FAI
VdS Class B - Viewguard DUAL FAI
EN 50131-1 and EN 50131-2-2, grade 2 VdS Class B
SES-EMA-RL-T2:2010-08 EN 50131-1 and EN 50131-2-4, grade 2
SES-EMA-RL-T2:2010-08
VdS approval no. see page 7.

The detectors are suitable for intrusion alarm panels with BUS-2/BUS-1- or conventional connection technology and are availa-
ble with or without Anti-Mask function (monitoring against covering).
To ensure optimum detection, detectors are equipped with high-quality mirror optics. Standard equipment includes a mirror for
area optics.

The Viewguard PIR detectors are motion detectors based on the passive infrared principle.
If required, the detectors can be retrofitted on site to long-range optics or curtain optics with accessories that are available sepa-
rately.

The Viewguard DUAL motion detectors comprise two sensor systems that operate independently:
• Passive infrared sensor and microwave sensor.
The functioning principle of the detector is based on an intelligent linking of the two sensor systems. This type of linking renders
the detectors particularly insensitive to air and thermal turbulences. Their distinguishing features being optimum alarm detection
and extremely high false alarm security.
Features

Anti-Mask function (only AM detectors)


• Detects covering, spraying or taping of the foil.
LED indication
• Clearly arranged indication of operating state via two LEDs. Walktest indication.
FAI-logic (First alarm indication, all types)
• The detector that is triggered first, can be identified with the aid of the LED indication.
Walk test function
• Easy way to check function and detection area.
Detector zone input (only BUS detectors)
• Integration of contacts/potential-free detectors in the BUS-2/ BUS-1 system (zone not erasable).
Microwave sensor (only DUAL detectors)
• Can be deactivated in the "disarmed" state.

Function overview PIR detectors

Viewguard PIR motion detectors Viewguard PIR Viewguard PIR AM


Function overview

T ype F AI BUS-2/ BUS-1 F AI BUS-2/ BUS-1


Item no. 033330.01 033332.21 033430.01 033432.21
VdS approval Class B Class B Class C Class C
As per EN 50131-2-2 Grade 2 Grade 2 Grade 3 Grade 3
Operating mode FAI FAI EL BUS-2 BUS-2 BUS-1 FAI FAI EL BUS-2 BUS-2 BUS-1
View- SCM View- SCM View- SCM View- SCM
Functions guard 3000 guard 1) 3000 guard 3000 guard 1) 3000

Area optics (state of delivery) X X X X X X X X X X X X


Convertible to long-range or curtain optics X X X X X X X X X X X X
Anti Mask uo to approx. ca. 30 cm (AM) — — — — — — X X X X X X
Anti Mask active or inactive in armed state — — — — — — X — — X — —
Anti Masc automatically inactive in armed state — — — — — — — X — — X X
Anti Mask allways ative — — — — — — — — X — — —
Alarm indication after disarming X X — X X X X X — X X X
First alarm indication via interval LED indication X X — X — — X X — X — —
Alarm memory X X — X X X X X — X X X
PIR sensitivity programmable in 2 stages X X X X X X X X X X X X
PIR range programmable in 4 stages X X X X X X X X X X X X
Detector group input (without clear function) — — — X — 2) — — — X — 2)
Temperature alarm, alarm thresholds can be programmed — — — X — — — — — X — —
Walk test function (with LED indication) X X X X X X X X X X X X
Walk test activation directly through the panel X — — X — — X — — X — —
Walk test activation via "clear detector group" — X — — X X — X — — X X
Walk test automatically active after initialising is completed — — X — — — — — X — — —
Cyclical self-test (PIR function) — — — — — — X X X X X X
Monitoring of operating voltage X X X X X X X X X X X X
Fault message to the panel X X 3) X X X X X 3) X X X
Fault/cover signal: save or don't save X X — X X — X X — X X X
Fault/cover signal: only don't save — — X — — X — — X — — —
Cover contact/tear-off protection X X — X — — X X — X — —
EL Easy Logic mode. Only operating voltage and alarm output used (not as per VdS)
1) Viewguard mode on BUS-2 is supported from panel software V07 (HB/MB24, HB/MB48, MB100).
2) Operation on BUS-1: The detector group is connected in an "OR" function with the alarm message
3) The "Alarm" and "Fault" outputs can be connected in series.
Detection range
• Range programmable in four stages.
Detection sensitivity
• Sensitivity programmable in two stages.
Save fault / do not save fault
• Save: Fault is saved until it is cleared.
• Do not save: Fault signal is reset automatically after eliminating the fault.
Self-test (only AM detectors)
• Correct functioning of the detector is monitored in cycles.
Monitoring of operating voltage
• Fault message if the operating voltage drops to low.
Temperature measurement (only BUS-2 application)
• Temperature alarm if ambient temperature is too high/too low. Programmable alarm thresholds.
Tear-off protection/Cover contact

Function overview DUAL detectors

Viewguard DUAL motion detectors V iewg u ard D U A L V iewg u ard D U A L A M


Function overview

T ype FAI B US - 2 / B US - 1 FAI B US - 2 / B US - 1


Item no . 033441.01 033443.21 033440.01 033442.21
VdS appro val Class B Class B Class C Class C
A s per EN 50131-2-4 Grade 2 Grade 2 Grade 3 Grade 3
O p eratin g m od e FA I FA I EL B US-2 B US-2 B US-1 FA I FA I EL B US-2 B US-2 B US-1
View- SCM View- SCM View- SCM View- SCM
F u n ction s guard 3000 guard 1) 3000 guard 3000 guard 1) 3000
A rea o ptics X X X X X X X X X X X X
A nti M ask uo to appro x. ca. 30 cm (A M ) — — — — — — X X X X X X
A nti M ask active o r inactive in armed state — — — — — — X — — X — —
A nti M asc auto matically inactive in armed state — — — — — — — X — — X X
A nti M ask allways ative — — — — — — — — X — — —
A larm indicatio n after disarming X X — X X X X X — X X X
First alarm indicatio n via interval LED indicatio n X X — X — — X X — X — —
A larm memo ry X X — X X X X X — X X X
P IR sensitivity pro grammable in 2 stages X X X X X X X X X X X X
M W sensitivity pro grammable in 2 stages — — — X — — — — — X — —
M W sensitivity auto matically as P IR sensitivity X X X — X X X X X — X X
P IR range pro grammable in 4 stages X X X X X X X X X X X X
M W range P IR and M W o perate auto matically with the same range
M W active o r inactive in disarmed state — — — X — — — — — X — —
M W auto matically inactive in disarmed state X X — — X X X X — — X X
M W allways ative — — X — — — — — X — — —
Detecto r gro up input (witho ut clear functio n) — — — X — 2) — — — X — 2)
Temperature alarm, alarm thresho lds can be pro grammed — — — X — — — — — X — —
Walk test functio n (with LED indicatio n) X X X X X X X X X X X X
Walk test activatio n directly thro ugh the panel X — — X — — X — — X — —
Walk test activatio n via "clear detecto r gro up" — X — — X X — X — — X X
Walk test auto matically active after initialising is co mpleted — — X — — — — — X — — —
Cyclical self-test (P IR functio n) — — — — — — X X X X X X
Cyclical self-test (M W functio n) — — — — — — X X X in preparatio n
M o nito ring o f o perating vo ltage X X X X X X X X X X X X
Fault message to the panel X X 3) X X X X X 3) X X X
Fault/co ver signal: save o r do n't save X X — X X — X X — X X X
Fault/co ver signal: o nly do n't save — — X — — X — — X — — —
Co ver co ntact X X — X — — X X — X — —
Tear-o ff pro tectio n X X — — — — X X — X — —
EL Easy Lo gic mo de. Only o perating vo ltage and alarm o utput used (no t as per VdS)
1) Viewguard mo de o n B US-2 is suppo rted fro m panel so ftware V07 (HB /M B 24, HB /M B 48, M B 100).
2) Operatio n o n B US-1: The detecto r gro up is co nnected in an "OR" functio n with the alarm message
3) The "A larm" and "Fault" o utputs can be co nnected in series.
Detection coverage Area optics

Optics 2. Mounting height 3.20 (3.00 m to 3.40 m


Area optics with sneak-by guard (state of delivery)
Horizonal detection coverage
Lens splitting 22 zones at 5 levels
Opening angle 80° hor., 64° vert.
Range 8 / 11 / 13 / 15 m (PIR and MW operate 40°
6m PIR
automatically with the same range)
MW
30°
Mounting height
20°
Recommended: 2.5 m for optimal operating sensitivity. 3m

Permitted: 2.2 m to 3.4 m PIR detectors 10°


2.2 m to 4.0 m DUAL detectors

ATTENTION! Important note for mounting heights of more than 0 0°


3.00 m:
In case of mounting heights of 3.00 to 3.40 m, the close range 10°
between 0 - 1.50 m cannot be monitored completely despite the
requirements for VdS systems of class C (see detection coverage 3m
20°
diagram on right side).
As the case may be, the respective areas must be monitored 30°
separately by appropriate means (such as a second detector). Expected
6m direction 40°
of motion
Detection diagrams
The following diagrams refer to a range setting of 15 m. 0 3m 6m 9m 12m
Note: The detectors have a high immunity against false alarms Vertical detection coverage
without reference surface
Vertical inclination 3° downward
1. Mounting height 2.5 m ( 2.20 to 3.00 m) 3.2m
Horizonal detection coverage
9m
40°
PIR
0 3m 6m 9m 12m
MW
6m 30°
3. Mounting height 3.70 (3.40 m to 4.00 m)
20°
(only DUAL detectors)
3m Horizonal detection coverage
10°
6m
40°
PIR
MW
0 0° 30°

3m 20°

10°
10°
3m

20° 0 0°

10°
6m
30°
Expected 3m 20°
direction 40°
of motion 30°
Expected
9m direction 40°
0 3m 6m 9m 12m 15m of motion

Due to the additional microwave, the dual detector has a very high 6m
detection capacity even with diagonal movement. 0 3m 6m 9m 10m
Vertical detection coverage, vertical inclination 7° downward
Vertical detection coverage
Vertical inclination 0° 3.7m
2.5m

0m 3m 6m 9m 12m 15m 0 3m 6m 9m 10m


Detection coverage Viewguard PIR Replacement Mirror sets

The Viewguard PIR Replacement Mirror sets are not suitable for DUAL detectors.

approval in combination with all VdS approved Viewguard PIR detectors (approval no. see page 7).
- Viewguard PIR Class B
- Viewguard PIR AM Class C

• Curtain optics

033434 Viewguard PIR mirror, Curtain optics Horizonal detection coverage


(PU = 3 piece) 0.5m
0.5m
The curtain mirror is suitable for monitoring possible 0 5m 10m 15m 20m 25m 30m
intrusion locations.
mirror distribution 11 zones on 11 levels Vertical detection coverage, Mounting height 2.50 m
acceptance angle 7.5° hor., 85° vert.
Vertical inclination 0°
range 17 / 21 / 25 / 30 m 2.5m

Mounting height:
- Recommended: 2.50 m 5m 10m 15m 20m 25m 30m

- Permitted: 2.20 m to 3.00 m

• Long-range optics

033435 Viewguard PIR mirror, Long-range optics Horizonal detection coverage


(PU = 3 piece) 1.5m
0
The long-range mirror is suitable for monitoring 1.5m
0 10m 20m 30m 40m 50m
corridors.
mirror distribution 8 zones on 6 levels Vertical detection coverage, Mounting height 2.50 m.
acceptance angle 30° hor., 78° vert.
Vertical inclination 0°
range 29 / 35 / 42 / 50 m
2.5m

Mounting height: 0 10m 20m 30m 40m 50m


- Recommended: 2.50 m
- Permitted: 2.20 m to 3.00 m

Retrofitting of the mirror optics


1
Easy retrofitting of the mirror optics on site:

1. Remove screw
2. Fold up mirror
3. Remove mirror

Installation: 3
Insert the new mirror in reverse order. Insert the
screw and tighten slightly. Close housing.
2
Mounting

45°
1. Mounting directly on the wall a)
Mounting possibilities:
- 0° Vertical at a 0° downward angle 1
+/-0°
- 3° Vertical at a 3° downward angle 2 1 2 3 b) 4
- 45° Horizontal at a 45° angle to the left
or right 3
- Corner mounting 4
c)

45°

Please note:
When installed in accordance with VdS systems class B and C, the backtamper must be used.
Backtampre is not possible when installing as per Fig. 3 a) and 3 c) (PIR detectors) or Fig. 3 c) (DUAL detectors)
The only exceptions are class B detectors without backtamper.

2. Mounting on Adjustable joint (Accessories, Item no. 033390.17)

Should the mounting possibilities in accordance with Fig. above not suffice, the detector can be mounted on the "Adjustable joint".
Swivel range: ±20° horizontal, +4° to -8° vertical.
Detector on Adjustable joint as per EN grade 2.
±20°
45°

+4°
Mounting possibilities:
- Mounting directly on the wall 5 0°
- 45° Horizontal at a 45° angle to the left 5 6 7
or right 6
- Corner mounting 7 -8°

Adjustable joint 45°

The adjustable joint is not provided with a backtamper!


For the installation in VdS systems of class B and C, a solid basis with the defined inclination is required on site to ensure proper
functioning of the backtamper.
The only exceptions are class B detectors without backtamper.

3. Mounting on Ball-and-socket set (Accessories, Item no. 033588.17)

The Ball-and-socket set provides the most versatile adjustment possibilities.


Swivel range: ±45° horizontal, ±20° vertical.

Mounting on Ball-and-socket set not as per VdS and EN.


Technical Data

Operating voltage U_b 12 V DC


Operating voltge range 8.0 V to 15 V DC
Current consumption at U_b=12 V DC:
PIR PIR detector: 1.6 mA (BUS-2 and FAI), 3.0 mA (BUS-1)
DUAL detector: 6.6 mA (BUS-2 and FAI), 9.0 mA (BUS-1)
LED 4 mA
Detection range (programmable):
Area optics 8 / 11 / 13 / 15 m
Long-range optics (Item no. 033435) 29 / 35 / 42 / 50 m
Curtain optics (Item no. 033434) 17 / 21 / 25 / 30 m
Detection sensitivity (programmable): normal / high
PIR sensor temperature compensated
Anti-Mask function (only AM detectors) up to 30 cm
Frequency microwave (only DUAL detectors) 9.35 GHz (X band)
Contacts: (only FAI detectors)
Alarm- and fault contact 15 V DC / 0.1 A, Internal resistance £25 W
Tamper contact 15 V DC / 0.1 A, Internal resistance £10 W
Protection category as per EN 60529 IP 30
Environmental class as per VdS II
Operating temperature range -10 °C to +55 °C
Storage temperature range -25 °C to +70 °C
Dimensions W x H x D PIR detector: 64 x 130 x 48 mm
DUAL detector: 64 x 158 x 48 mm
Colour traffic white (similar to RAL 9016)

VdS approval no.

Item no. 033432.21 Viewguard PIR AM BUS-2/BUS-1 G108036, IDS Class C, with area optics
G108037, IDS Class C, retrofitted with curtain optics
G108038, IDS Class C, retrofitted with long-range optics

Item no. 033332.21 Viewguard PIR BUS-2/BUS-1 G108509, IDS Class B, with area optics
G108510, IDS Class B, retrofitted with curtain optics
G108511, IDS Class B, retrofitted with long-range optics

Item no. 033430.01 Viewguard PIR AM FAI G107087, IDS Class C, with area optics
G107088, IDS Class C, retrofitted with curtain optics
G107091, IDS Class C, retrofitted with long-range optics

Item no. 033330.01 Viewguard PIR FAI G107509, IDS Class B, with area optics
G107510, IDS Class B, retrofitted with curtain optics
G107513, IDS Class B, retrofitted with long-range optics

Item no. 033442.21 Viewguard DUAL AM BUS-2/BUS-1 G108039, EMT Class C

Item no. 033443.21 Viewguard DUAL BUS-2/BUS-1 G108512, EMT Class B

Item no. 033440.01 Viewguard DUAL AM FAI G108078, EMT Class C

Item no. 033441.01 Viewguard DUAL FAI G108518, EMT Class B


Ordering information

Item no. Designation

033432.21 Viewguard PIR AM BUS-2/BUS-1

033332.21 Viewguard PIR BUS-2/BUS-1

033430.01 Viewguard PIR AM FAI

033330.01 Viewguard PIR FAI

033442.21 Viewguard DUAL AM BUS-2/BUS-1

PIR DUAL 033443.21 Viewguard DUAL BUS-2/BUS-1


PIR AM DUAL AM
033440.01 Viewguard DUAL AM FAI

033441.01 Viewguard DUAL FAI

Accessories

Item no. Designation

Mirrors sets:
033434 Viewguard PIR Replacement Mirrors
Curtain mirror Curtain mirror, (PU = 3 piece)

033435 Viewguard PIR Replacement Mirrors


Long range mirror Long range mirror, (PU = 3 piece)

Mounting Accessories:
033390.17 Adjustable joint for motion detectors
Adjustable joint suitable for wall and corner mounting
horizontal ±20°, vertical +4° to -8°
as per EN grade 2

033588.17 Ball-and-socket set for wall and corner mounting


Ball-and-socket set horizontal ±45°, vertical ±20°
not as per VdS and EN

033391.17 Seal (PU = 20 piece)


Seal
033436 Viewguard spare parts wall-tamper

Honeywell Security Group


Novar GmbH
Johannes-Mauthe-Str. 14
72458 Albstadt
Telefon +49(0) 74 31/801-0
Telefax +49(0) 74 31/801-12 20 P01543-22-0G0-03
www.honeywell.com/security/de 04.2015 " Subject to change without notice
info.security.de@honeywell.com © 2015 Honeywell International Inc.