You are on page 1of 2

cfs0018_UK_R1_menvier-data-sheets_Layout 1 04/08/2011 12:03 Page 17

Conventional Product Range

Standard Base MDB800


Suitable detectors for use with
the MDB800 standard base

MPD821 optical detector

MDB800 standard base

Overview Features
MPT951 photo-thermal detector
The MDB800 Menvier conventional base has been • Quick and simple to install
specifically designed to be compatible with the • Separate zone in and zone out
terminals
Menvier range of conventional detectors.
• Stand off fixing feature
• Selectable detector locking
This standard base has been designed for flexibility,
simplicity and speed of installation.
Benefits
It incorporates purpose designed devices to provide
fault warning if detector is removed whilst • Accepts side entry surface
maintaining full zone wiring integrity. cables
• Common base for Menvier
The base has a spring contact switch and a parallel conventional detectors
zener diode to enable fault monitoring.

MFR830, MMT860, MHT890 heat detectors


cfs0018_UK_R1_menvier-data-sheets_Layout 1 04/08/2011 12:03 Page 18

Conventional Standard Base - MDB800

Dimensions Technical Specification


Dia (mm) D (mm) Code MDB800

104 22 Description Standard base


Physical
D Construction PC/ABS
Colour White
Dimensions (Dia x D) 104mm x 22mm
Compatibility
Suitable for use with Menvier conventional detectors

Dia

Installation Interface Options


1. Base incorporates a retaining clip to provide 1. Menvier conventional
positive feedback when detector is correctly fitted. detectors and bases support
2. Separate terminals are provided for zone in and the use of a remote LED
zone out connections. (optional extra CIR301).
3. Each terminal can accept up to 2 x 2.5mm cables
4. Base incorporates a substantial cable entry
aperture in the rear of the base.
5. Breakouts are provided to enable the detector
base to sit neatly over surface cables and then
enter via the rear entry aperture.
6. Base mounting incorporates a stand off feature to
help prevent distortion when mounted on an
uneven surface.
7. Fixings are suitable for standard BESA box or
direct fixing to suitable surface
8. Optional locking devices (supplied with base) to
prevent unauthorised detector removal.

Standard Connection
+ VE
+
remote indicator (optional)
Menvier Conventional

+ LED

end of line resistor


LED
1 1
Control Panel
Compatible

4 4
ZONE

2 E 2 E

- 3 3

- VE

WARNING:
If using the outer connection on terminal 2, ensure the operation of the switch is not impeded
and that there are no shorts between terminal 2 and the switch contact - use sleeves for end
of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code Description
MDB800 Conventional standard base
MDB800*10 Conventional standard base (pack of 10)
CIR301 Conventional remote indicator

Cooper Lighting and Safety Ltd, Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB. UK.
T: +44 (0) 1302 303350 l F: +44 (0) 1302 303332 l E: techsupport@cooperfire.com l W: www.cooperfire.com

You might also like