350kW NG/LP Dual Fuel Mobile Generator Set

Specifications
Rated Winding Prime Power Speed
Frequency Phase Rated Amps
Voltage (V) Configuration kW (kVA) (rpm)
60 Hz 480/177 Hi-Wye 3 350 (437.5) 526 1800
60 Hz 240/139 Lo-Wye 3 350 (437.5) 1052 1800
60 Hz 208/120 Lo-Wye 3 346 (432.5) 1200 1800

PSI Heavy Duty 21.9L Natural Gas/LP Engine Metric Imperial (English)
Number of Cylinders V12
Type 4 Stroke Cycle
Bore 128 mm 5.04 in
Stroke 142 mm 5.59 in
Displacement 21.9 L 1338 in3
Compression Ratio 10.5
Engine Speed rpm 1800
Aspiration Turbo Charged Air Cooled
Fuel NG, LP, LNG, CNG
Generator Set Data
Prime Rated Power 350 ekW
kVA rating 437 kVA
Rated power factor 0.8 pf
Frequency 60 Hz
350kW NG/LP Dual Fuel Mobile Generator Set

Specifications (continued)
Stamford Alternator
Frame size S4L1D-G - Winding 311
Pitch 2/3
No. of Poles 4
Excitation PMG excited
Constructions Single bearing
Insulation UL 1446 Class H
Enclosure Drip-proof IP23
Temperature rise 105°C
Alignment Close coupled
Wave form deviation Less than 5%
Telephone Influence Factor (TIF) Less than 50
Harmonic Distortion(THD) Less than 5%

Performance Specification
Units
Engine standby power 510 (684) bkW (bhp)
Engine prime power 434 (581) bkW (bhp)
BSFC @ 100% load 11.3 (8,013) MJ/bkW-hr (Btu/bhp-hr)
Induction air flow rate 27 (968) m3/min (ft3/min)
Cooling air flow rate 1,133 (40,000) m3/min (ft3/min)
Max exhaust stack temperature 732 (1,350) °C (°F)
Exhaust flow rate 84.8 (2,995) m3/min (ft3/min)
Engine oil system capacity 40 (10.5) L (gal)
Engine coolant capacity 52 (13.7) L (gal)
Radiator coolant capacity 176 (46.5) L (gal)
Oil change interval 750 Hours

Weight and Dimensions


Length Width Height Weight with Lube oil and
Model
(ft) (ft) (ft) Coolant (lbs)
350kW Mobile
23’ 7” 8’ 9’ 11” 17,060
Generator
350kW NG/LP Dual Fuel Mobile Generator Set

Standard Features
Stamford Alternator Sound Attenuated Container
• UL listed S4L1D-G • Temperature controlled enclosure for harsh climates
• Cont. F - 105/40°C Rating • Sound attenuated air intake system
• 510kVA, 408kW, 93.9% Efficiency • Motorized actuated louvers programmed for optimal
• 4-pole, Permanent Magnet Generator (PMG) temperature control
Excitation • Three lockable doors with panic release
Voltage Regulation • External hookups for oil and coolants drain and fill
• Field-Proven MX341 base regulation • Meets 75 dB(A) at 7 meters sound performance
• 3-phase digital sensing (RMS) and adjustments • Full spill containment of onboard engine fluids with
through bias adjustment from DSE8610 MKII easy drain access
• Low-draw LED work-lighting
Load Sharing • Custom Paint Scheme
• DSE 8610MKII provides fully automated voltage
Distribution Panel
bias and governor control
• 480/277V, 240/139V, 208/120V, 3-phase
• High-speed CANBUS load share communications
• Door safety switch for breaker trip
between generators
• 3 - position selector switch for easy reconfiguration,
• Standard kW sharing and kVAR sharing balanced
@ 480V, 240V, 208V
between generators
• 3 X 400A camlock receptacles per phase, neutral, and
• Other options included: Fixed Export, Fixed PF
ground connections
control, Power vs Frequency (IEEE 1547 curves),
• 4 conductor terminal, double set-screw 2AWG -
and Reactive Power vs Voltage (IEEE 1547 curves)
600MCM per phase, neutral, and ground
Control Panel
• Onboard Deep Sea 8610 MKII parallel controlled Side Customer Access
• Idle/rated switch • Separate control panel, distribution panel, and
• 3 Fuel Control Modes: NG, LP, Auto circuit access doors
• Generator protection features: 27, 32 L/R, 37 P, 40, • External emergency stop push button
46, 50 P, 51 P/G, 59, 81 O/R/U • Remote start/stop contacts
• Metering display: voltage, current frequency, • Lock out tag out switch
power factor, kW, WHM, and kVAR Telemetry
• Panel illumination light and emergency stop switch • Telematics capable of integration
• Manual and automatic paralleling capability • Dual-carrier satellite and cellular access
• Automatic start/stop switch with cool down timer • Provides access to: engine data, electrical data, aver-
• RS485 and ethernet modbus options age total power, peak total power, fuel consumption,
Trailer Features physical location real time status, etc.
• 2 - 5/16 ball hook up
• 2 - 8,000 lb axle
• 4 - way leveling jacks
350kW NG/LP Dual Fuel Mobile Generator Set

Standard Features (continued)


Circuit Breaker Rental-ready Features
• 1600 fixed type, 3 poles, generator set mounted, • Anti-condensation heater 110-120 VAC
electrically operated with electronic trip unit • Coolant Heater 110-120 VAC
• 50 KA-interrupting capacity at 480 VAC • UL Listed battery charger
• Shunt trip Cooling System
Current Transformers • Provides 40 degrees Celsius (104 degrees F)
• CTs rated 1200:5 ambient capability at 100% continuous rating
Starting System before de-rating
• Single electric starting motor, 24VDC Auxillary Distribution System
• Dual 12V maintenance free batteries with lock out • Shore power connection via distribution block
tag out disconnect switch, battery rack, and cables connections for jacket water heater, battery
• UL/CSA listed, 120 volt single phase jacket water charger, and generator condensation heaters,
heater with thermostat and shut off valves, auto duplex service receptacle
disconnect on start-up • Remote start/stop terminals
Certifications Fuel System
• Engines are EPA certified • LNG, CNG, LP, Natural Gas
• Onboard LP vaporization and automatic, seam-
less switch between LP and natural gas under
an electrical load
• Stoichiometric air fuel mixture with NSCR
catalyst
• Capable of switching fuel sources at upwards of
Emissions 75% load
PSI Heavy Duty 21.9L Engine PSI Heavy Duty 21.9L Engine
(NG) (LP)
g/hp-hr g/hp-hr
BSCO 0.198 0.210
BSCO2 462.70 657.19
BSCH4 0.015 0.000
BSTHC 0.015 0.035
BSNMHC 0.000 0.035
BSNOx 0.006 0.024
BSTHC+NOx 0.021 0.059
BSNMHC+NOx 0.006 0.059
BSFC (kg/kW-hr) 0.169 0.199
The emissions are in accordance with ISO 8178 D1 weighted test cycle from a single engine. Actual field test results may vary based on operating conditions, fuel specification, testing procedures, and
engine age.
The above emission levels are not guaranteed emissions for purposes of air permitting. These rates are typical for a new, properly maintained and running engine.