1、 Product Name: Emergency Exit Sign Light 2、Input voltage: AC220-240V 50-60Hz 3 、Light source: White LED 4、 Emergency power: 3W 5、Transformation time: ≤0.25S 6、Charging time: <24 hours 7、Emergency time: 1.5 hours 8、Environment temperature: 0℃~55℃, Relative humidity: <95% 9、Battery specification: 1.2V/600mAH Ni-Cd battery pack 10、Texture: Aluminum + glass + iron board 11、The whole lamp warranty: two year, the battery life is one year 12、Weight: 0.36Kg Performance and instructions On the lamp: Three indicator light as red (charging), green (main power), yellow(trouble), and a test button. Power: The power source is normal if green light is on (note: this lamp has automatic voltage conversion circuit. It will turn to emergency status if voltage is 150v or so, and will turn to normal status when voltage recovers to about 170V. Please check if the voltage is in normal status when input.) It turns to monthly inspection when the light flashes slowly and to annual inspection when it flashes rapidly. Charge: Red indicator light. The lamp will charge automatically when it’s connected to AC220V. The battery is at charging status when the red light is on. The red light will be off after full charge, and it will turn to trickle of floating charge state so that life span of the lamp is longer. Trouble: Yellow light is on when the light is without battery, the line is not connected, protection tube is open circuit, battery is in short circuit or battery failure condition, and the charging circuit is in short circuit condition. The yellow light flashes rapidly when light source is in open circuit or short circuit condition, and when emergency circuit failure occurs. Yellow light keeps on when annual inspection time is not enough 30min. Test button: Through to AC220V, press the test button, simulation main electric power failure, emergency light should be lit state at this time, at the same time, the red light and green light is not bright, show that lamps should function normally. Loosen the button, restore the main electricity state; When in emergency, press the Test button to lamps and lanterns is not any change Over-discharge Protection: There’s accurate protection for over-discharge inside the light circuits. The over-discharge circuit will cut off the discharge circuit when the battery discharges to 82%-85% of the rated voltage. Current is zero after circuit cut off of in order to extend the life span of the lamp. Monthly and annual inspection: The Lamp has monthly and annual inspection function. If the lamp is working in normal condition or not discharged to the cut off condition, it will turn to emergency working status from normal status and last for 60 seconds every 30±2 days after 48H power on. Then it recovers to normal working status while the green light flashes slowly. If the lamp keeps working in normal condition for a year and not discharged to cut off condition, it will turn to emergency status and until discharge is finished. Then it will recover to normal condition and the green light start to flash rapidly. Size, installation size and method
Use 4cm steel nails or setscrew to fix the lamp on wall, through screw fixed hole on left and right sides of the bottom plate or through rings, and ensure its fastness and reliability.