You are on page 1of 2

/ 0123456789

PRODUCT INFORMATION

Cetamine® G900
Surface-Active Corrosion Inhibitor for Closed Cooling and Hot
Water Systems
Product description
Cetamine® G900 is an all-in-one corrosion inhibitor based on a CLOSED SYSTEMS
blend of a surface active Cetamine® Filming Amine (CFA),
alkalizing amines a polymer and copper inhibitor. Cetamine®
G900 prevents corrosion and scaling in closed cooling and hot
water systems by formation of a protective Cetamine® film on
metal surfaces and adjusting the pH-value to the optimal range.

Cetamine® G900 passivates metallic surfaces and provides


exceptional protection throughout the whole system of both all-
ferrous and mixed metallurgy systems.

Cetamine® G900 prevents scale formation due to the stabilizing


and dispersing effect of the CFA and the polymer component.

Application FEATURES & BENEFITS


Cetamine® G900 provides full protection in systems containing
steel, copper and copper alloy installations.
Metal passivation
Oxide layer stabilization
Cetamine® G900 is suitable for closed systems filled with
Online system cleaning
demineralized or reversed osmosis water quality. It also can be
Improved heat transfer
applied in systems filled with softened or tap water.
Significant reduction of corrosion and
iron transport
Due to the surface active properties of the Cetamine® Filming
Excellent protection during stoppages
Amine Cetamine® G900 has a cleaning effect and existing scale
and lay-up periods
or incrustations will be mobilized. In order to avoid long term
Improved environmental discharge
circulation of these solid particles through the system one of the
profile in case of system leakages or
following measures is recommended for the treatment transition
draining
to Cetamine® G900:
Free of nitrite with lower potential for
denitrifying bacteria grow
• Temporally installation of side stream filters Free of cyclohexylamine
• Temporally blow-down increase
• Flushing and preventive pre-cleaning of the system

For further information on cleaning of closed systems please


refer to Kurita Technical Information TI 270 “Cleaning and
passivation of closed systems with Cetamine® Technology”. PRODUCT COMPLIANCE
Dosage
The dose rate of Cetamine® G900 is system specific and needs According to DIN EN 1717:2000 (§ 5.2)
to be defined together with a Kurita representative. Generally the “Protection against pollution of potable
dose rate refers to the total system content and has to be water installations and general
adjusted until a pH value of 9.0 to 10.0 and a concentration of requirements of devices to prevent
CFA of 0.5 to 2.0 g/m³ has established in the system. In systems pollution by backflow”, Cetamine®
containing copper or copper alloys a pH value of 9.5 must not be G900 is to be classified in category 3.
exceeded.

1/2
/ 0123456789

PRODUCT INFORMATION

Cetamine® G900
Surface-Active Corrosion Inhibitor for Closed Cooling and Hot
Water Systems
In semi closed systems or systems with leakages where make-
up water replenishment is necessary an additional maintenance CHEMICAL & PHYSICAL
dosage is necessary. PROPERTIES
• Initial dose rate: 500 – 2000 g/m³ colorless to slightly
• Maintenance dose rate: 100 – 400 g/m³ Colour and
yellow, clear to
appearance
slightly turbid liquid
Cetamine® G900 should be injected by means of an automatic
dosing system and must be dosed neat.
Density (20 °C) 1.01 ± 0.03 g/cm³
Product monitoring
The CFA content can be determined by the Kurita Cetamine®
Photometric Method, “Cetamine® Test Kit or Cetamine® Monitor.
During routine plant inspections the presence of the protective pH (20 °C)
11.0 ± 0.5
Cetamine® film on accessible system surfaces can be 1% aqueous
demonstrated with the Kurita Cetamine® Wipe Test.

Storage A dilution of the


The product should be stored in the original package in the Solubility in water product is not
temperature range of 5 to 40 °C. recommended

Material compatibility
All parts of the dosing equipment coming into contact with the
concentrated product must be made of PE, EPDM or PTFE
(Teflon). The concentrated product is not compatible with FPM
(Viton). When applied at recommended dosages, there is no
record of incompatibility with FPM components.

Certification
Our quality management system (ISO 9001), environmental
management system (ISO 14001) and occupational health and
safety management system (BS OHSAS 18001) are successfully
certified by Lloyd´s Register.

Product Safety
For information regarding product safety please refer to Kurita
Safety Data Sheet

The information in this publication reflects our level of technical knowledge and experience at the time of print of this product information. The information is provided
by Kurita Europe GmbH at the best of its knowledge and in good faith. Within legal frameworks, it does not, however, constitute legal warranties, liabilities, covenants
or such by Kurita Europe GmbH but are provided as guidance only. This is notably true in view of particular characteristics or of fitness for a specific purpose of the
product. The above-mentioned information does not relieve the user of the product from the obligation of own examinations, appropriate precautionary measures
and tests due to the abundance of possible influences during storage, manufacturing and application of the product – this is explicitly recommended by Kurita
Europe GmbH. It shall be the responsibility of the recipient of our products to respect any intellectual property rights, existing laws and other provisions. If not
explicitly regulated differently and in writing, the General Terms and Conditions of Kurita Europe GmbH are unaffected by this product information.

Headquarters:
Kurita Europe GmbH
Theodor-Heuss-Anlage 2
68165 Mannheim
Germany Internet: www.kurita.eu
Phone: +49 621 1218 3000 Email: kuritaeurope@kurita-water.com
Fax: +49 621 1218 3600

2/2