Steps:
5 - Backup the important modules(patient) : D, AD and AS Importance level .19 and 73 as well. And ROM and FIPS.
7 - Check the problem track and its corresponding module. For example, TLIST and VLIST are on track 2. If track 2 has
Change 02 to a another good track (pay attention with hex code like tracks 10 (0A), 11 (0B))
10 - In MRT software, open "Hard Disk Information" and then "Load the module list from a file" and choose the 02
FIT saved file and reload the information.
11 - Save the changed modules to be recorded in the new tracks. INCLUDE 02 FIT because is a module dir changed.
THIS IS IMPORTANT.
12 - At this moment, your patient HDD will be ready for hot swap with the new track positions and be able to recover
your patient.
13 - You can save the important modules ( D, AS and AD) from your PATIENT to your DONOR.
17 – Clear A-LIST