You are on page 1of 8

Easy UPS 3S and 3M

Business continuity
made easy
Easy UPS 3S
10-40 kVA
220/230/240/380/400/415 V

Easy UPS 3M
60-200 kVA
380/400/415 V

se.com/ups
Business continuity
made easy
The Schneider Electric Easy UPS 3S and Easy UPS 3M are easy to install,
connect, use, and service 10-200 kVA 3-phase UPSs ideal for small and
medium businesses, data centers, and other mission-critical applications.

Easy UPS 3S and Easy UPS 3M uninterruptible power supplies deliver competitive specifications and
robust electrical design in an easy-to-use package. It is exceptionally easy to install, connect, operate,
maintain, and service, making it ideal for a wide range of small and medium business applications.
This EcoStruxure™ connected UPS features a wide operating temperature range and strong overload
protection, all in a compact and lightweight footprint. Start-up service* optimizes your system’s
performance, quality, and safety. The Easy UPS 3S and Easy UPS 3M are the easy choice for your
business continuity in the data center or electrical room.

Easy UPS 3S
• 10-40 kVA UPS with internal batteries
• 10-40 kVA UPS for external batteries

Easy UPS 3M
• 60-80 kVA UPS with internal batteries
• 60-200 kVA UPS for external batteries

Easy to install and start up


• Rolls into position quickly and easily
• Minimal footprint requirement with lightweight,
compact form factor
• Straightforward installation
• Input, output, and bypass breakers are included
100 kVA Easy UPS 3M 40 kVA Easy UPS 3S UPS
• Emergency Power Off (EPO) switch is included for external batteries with internal batteries
• Easy Loop test verifies UPS performance before
you connect your load, without the need for a
load bank
• Aesthetic design blends well into your installation Typical applications
environment
• On-site start-up* with Schneider Electric Field • Small and medium data centers
Service Representatives and computer rooms
*Included with Easy UPS 3M; recommended service option • Manufacturing facilities
for Easy UPS 3S • Telecommunication
• Commercial buildings
• Healthcare
• Transportation

2 Schneider Electric | Easy UPS 3S and Easy UPS 3M


Easy to use, connect, monitor, and manage Easy to expand
• User-friendly display interface supports • Parallel UPSs for capacity or redundancy:
easy configuration – Easy UPS 3S: Up to four UPSs
• With the included Network Management Card, you can: – Easy UPS 3M: Up to six UPSs
– Monitor UPS status remotely through a web interface
– Monitor and manage the UPS status and Easy to maintain
performance through EcoStruxure IT’s cloud-based • Front and rear access for service
and on-premise software suites, or through SNMP • Quickly and easily replace the dust filter conveniently
integration to the Network Management System of located behind the front door
your choice, bringing you peace of mind. • Schneider Electric service team available to make service
– Manage buildings through the BACnet protocol for easy and improve uptime with proper maintenance of
integration with Building Management your UPS and batteries
Systems (BMSs)
Robust and competitive
Versatile
• Easy UPS 3S and Easy UPS 3M bring predictability
Easy UPS 3S and Easy UPS 3M are easy to adapt for to utility costs, with up to 96% efficiency in double
your site requirements: conversion mode and up to 99% efficiency in
• Only pay for the options you need, with upgrade kits that ECO mode
enhance the resilience of the UPS • Minimize your power losses and cooling
• Internal, external, and third-party battery options requirements with up to unity power factor (kW=kVA)
• Galaxy Lithium-ion Battery Cabinets for Easy UPS 3M for • Protect your data center or electrical room with these
external batteries fortifying features:
• Common battery bank: Redundant UPSs can share the – Embedded dust filter
same battery bank, reducing battery costs – Conformal coating
• Extended runtime: – Operating temperature up to 40°C
– Easy UPS 3S UPSs with internal batteries include up – Wide input voltage range
to 93 minutes of runtime (Easy UPS 3S 10 kVA with 3
modular high capacity battery strings)
– Easy UPS 3M UPSs with internal batteries include
up to 24 minutes of runtime (Easy UPS 3M 60 kVA at
PF=0.8, 70% load)

Lithium-ion batteries
Save space and the environment Lithium-ion compared to VRLA batteries
As a first mover with a vast installed base, Schneider
Electric has developed our own Galaxy Lithium-ion
battery solution that pairs with Easy UPS 3M to deliver Higher
operating temp.
these benefits: (less cooling)

• Optimize TCO and achieve sustainability targets by


doubling your battery life
• Simplify and speed up installation with our internal
power supply
2 – 3X
expected life
• Enhance battery safety with three levels of battery
management system (BMS)

60 – 70%
less weight

2 – 3X
Faster recharge

Life Is On | Schneider Electric 3


Easy UPS 3S

Easy UPS 3S for external batteries Easy UPS 3S with internal batteries
UPS rating 10-15 kVA 20-40 kVA 10-20kVA 30-40kVA
Dimensions 530 x 250 x 700 mm 770 x 250 x 800 mm 1400 x 380 x 928 mm 1400 x 500 x 928 mm
(HxWxD)
Batteries VRLA: external classic battery cabinet VRLA: internal modular battery strings
IP level IP20
Special 10-30 kVA: 3:3 or 3:1-phase UPS available
features 40 kVA: 3:3-phase UPS available

Easy UPS 3M

Easy UPS 3M for external batteries Easy UPS 3M with


internal batteries
UPS rating 60-100 kVA 120-160 kVA 200 kVA 60-80 kVA
Dimensions 915 x 360 x 850 mm 1300 x 500 x 850 mm 1300 x 600 x 850 mm 1970 x 600 x 928 mm
(HxWxD)
Batteries VRLA: external classic battery cabinet VRLA: internal modular
Li-ion: Galaxy Lithium-ion Battery Cabinet battery strings
IP level IP20 (up to IP42 with optional kits)

Options and accessories

• Modular high-capacity battery string


• Temperature sensor
• Dust filter kit
• Parallel kit
• Parallel or unitary maintenance
bypass panels
• Battery breaker box
• Battery breaker kit
• Backfeed boxes
• Empty auxiliary cabinet
Empty battery Modular battery cabinet Classic battery cabinet with Galaxy Lithium-ion Battery • Cable kit for adjacent installation of
cabinet for battery for extended runtime factory installed long-life Cabinet (available for Easy classic battery cabinet (available for
installation on-site requirements (compatible batteries,for quick and UPS 3M) Easy UPS 3M)
with Easy UPS 3S and easy installation on-site
• Start-up service (included with Easy
Easy UPS 3M 60-80 kVA (available for Easy UPS 3M)
with internal batteries) UPS 3M; recommended service
option for Easy UPS 3S)
• IP30, IP40, and IPX2 kits (available for
Easy UPS 3M)
4 Schneider Electric | Easy UPS 3S and Easy UPS 3M
Easy Monitoring,
Management, and Services
EcoStruxure IT enables resilient, secure, and sustainable data centers and
IT environments

Schneider Electric’s comprehensive Data Center Infrastructure Management (DCIM) solution,


EcoStruxure IT, ensures business continuity by enabling secure monitoring, management, insights, Resilient

planning, and modeling - whether from a single IT rack to hyper- scale IT – on-premises, in the cloud,
and at the edge.

With the included Network Management Card, you can deploy EcoStruxure IT software and services to Secure
enhance monitoring and management of your Easy UPS 3S or 3M.

Easy visibility
Monitoring and management software that streamlines data center Sustainable
device management:
EcoStruxure IT Expert provides you a hands-on
approach with cloud-based monitoring software
that synthesizes and analyzes performance Comprehensive on-site services
and alert data into proactive recommendations Start-up service*
and enables wherever-you-go visibility from any
device. • Commission the installation in
Try it now: www.ecostruxureit.com/ecostruxure- accordance with manufacturer’s
it-expert/#trial recommendations. Ensure optimal
system performance from Day 1.
EcoStruxure Data Center Expert is a scalable
end-to-end on-premise monitoring software Schneider Electric-certified
that collects, organizes, and distributes critical installation services
device information, providing a comprehensive • Expert configuration of your
view of your company-wide multi-vendor physical equipment for optimal performance
infrastructure. and reliability.

24/7 peace of mind Maintenance services


Digital services proactively monitor your critical devices: • Ensure proper care of your mission-
EcoStruxure Asset Advisor* for secure critical applications.
power and cooling provides you a hands-off • Preventive maintenance and response
approach with 24/7 remote monitoring service time upgrades, where available.
by the Schneider Electric Connected Services
Hub experts. Flexible service plans / on-site
extended warranty
We monitor and troubleshoot, you relax.
• Hassle-free system maintenance.
Operations, optimized • Improve uptime at a predictable cost.

Planning and modeling software transforms data into performance insights: *Included with Easy UPS 3M; recommended
service option for Easy UPS 3S
EcoStruxure IT Advisor is a data center
infrastructure planning and modeling solution
that provides Data Center Managers in large
enterprises and colocation data centers with
full insights into their infrastructure to improve
profitability, sustainability, and resiliency.
Life Is On | Schneider Electric 5
Easy UPS 3S technical specifications
Rated Power (kVA/kW)

Easy UPS 3:1 10/10 15/15 20/20 30/30

Easy UPS 3:3 10/10 15/15 20/20 30/30 40/40

Normal AC supply input


Input voltage (V) 380/400/415 V (3-phase + Neutral)
Frequency (Hz) 45 – 65 Hz
Input power factor >0.99
THDI <3% for 10 kVA UPS, <4% for 15-40 kVA UPS
Input voltage range 304 to 477 V at full load

Dual mains input Yes (default: single mains input)

Output
3:1 – 220/230/240 V
Nominal output voltage (V)
3:3 – 380/400/415 V
Efficiency: Double conversion mode Up to 96%
Efficiency: ECO mode Up to 99%
Overload capacity in normal operation 130% for 10 minutes and 130-150% for one minute
Output voltage tolerance +/-1%
Communication and management
Communication interface RS485, dry contacts, Ethernet (SNMP, Modbus, TCP/IP, BACnet)
Control panel Multi-function LCD, status and display console
Weights and dimensions

UPS for external batteries, unpackaged/ 530 × 250 × 700 mm/ 530 × 250 × 700 mm/ 770 × 250 × 800 mm/ 770 × 250 × 800 mm/ 770 × 250 × 900 mm/
shipping dimensions (H × W × D, mm) 772 × 400 × 857 mm 772 × 400 × 857 mm 1015 × 400 × 982 mm 1015 × 400 × 982 mm 1015 × 400 × 1050 mm

UPS for internal batteries, without


1400 × 380 × 928 mm/ 1400 × 380 × 928 mm/ 1400 × 380 × 928 mm/ 1400 × 500 × 969 mm/ 1400 × 500 × 969 mm/
batteries, unpackaged, shipping
1640 × 563 × 1014 mm 1640 × 563 × 1014 mm 1640 × 563 × 1014 mm 1640 × 683 × 1114 mm 1640 × 683 × 1114 mm
dimensions (H x W x D, mm)

UPS for external batteries,


36/50 36/50 58/75 60/77 70/86
unpackaged/shipping weight (kg)

UPS for internal batteries, without batteries,


112/145 112/145 122/158 152/190 158/195
unpackaged/shipping weight (kg)

Battery string (1 string/4 modules),


27 kg per module/28 kg per module
unpackaged/shipping weight (kg)

Regulatory
Safety IEC/EN62040-1-1 Performance IEC 62040-3
EMC/EMI/RFI IEC 62040-2 Environmental IEC 62040-4
Markings CE.RCM, EAC, WEEE
Battery type
Battery type VRLA
Nominal DC bus (100% load) +/-192 to +/-240
Charging power in % of output power
1-20%
(selectable)
Environmental
Operating temperature 0°C to 40°C
Relative humidity 0 to 95% non-condensing
Operating elevation 0 to 1,000 m at 100% load
Audible noise at 1 m from unit 10-20 kVA: 60 dBA at 100% load; 30-40 kVA: 63 dBA at 100% load
Protection class IP20

One year with Schneider Electric-certified Field Service Representative


Warranty
or Certified Service Partner Start-up Service (sold separately)

*Under 30°C

6 Schneider Electric | Easy UPS 3 Series


Easy UPS 3M technical specifications
Rated Power (kVA/kW) 60/60 80/80 100/100 120/120 160/160 200/200

Normal AC supply input

Input voltage (V) 380/400/415 V (3-phase + Neutral + PE)

Frequency (Hz) 40–70 Hz

Input power factor >0.99

THDI <3% at full linear load

Input voltage range 342 to 477 V at full load at 40°C**

Dual mains input Yes (default: single mains input)

Output

Nominal output voltage (V) 3:3 – 380/400/415 V

Efficiency: Double
Up to 95.5%
conversion mode

Efficiency: ECO mode Up to 99%

Overload capacity in
125% for 10 minutes, 150% for 1 minute*
normal operation

Output voltage tolerance +/-1%

Communication and management

Communication interface RS485, dry contacts, Ethernet (SNMP, Modbus, TCP/IP, BACnet)

Control panel Five inch touchscreen LCD, status, and display console

Weights and dimensions

UPS for external batteries,


915 × 360 × 850 mm/ 915 × 360 × 850 mm/ 915 × 360 × 850 mm/ 1300 × 500 × 850 mm/ 1300 × 500 × 850 mm/ 1300 × 600 × 850 mm/
unpackaged/ shipping
1140 × 475 × 965 mm 1140 × 475 × 965 mm 1140 × 475 × 965 mm 1500 × 625 × 975 mm 1500 × 625 × 975 mm 1500 × 725 × 975 mm
dimensions (H × W × D, mm)

UPS with internal batteries,


1970 × 600 × 1000mm/ 1970 × 600 × 1000mm
unpackaged/shipping
2102 × 750 × 1125mm 2102 × 750 × 1125mm
dimensions (HxWxD, mm)

UPS for external batteries,


unpackaged/shipping, 109/133 140/164 145/169 193/223 227/257 304/338
weights (kg)

UPS for internal batteries,


without batteries,
311 (360) 339 (387)
unpackaged/shipping
weight (kg)

Regulatory

Safety IEC/EN 62040-1 Performance IEC62040-3

EMC/EMI/RFI IEC 62040-2 Environmental IEC 62040-4

Markings CE TUV

Battery type

Battery type UPS with internal batteries: VRLA; UPS for external batteries: VRLA or Lithium-ion

Nominal DC Bus (100% load) +/-216 to +/-300

for external for external


Charging power in % of batteries: 1-20% batteries: 1-30% for external for external for external for external
output power (selectable) with internal with internal batteries: 1-24% batteries: 1-20% batteries: 1-22.5% batteries: 1-24%
batteries: 1-16% batteries: 1-24%

Environmental

Operating temperature 0 to 40°C

Relative humidity 0 to 95% non-condensing

Operating elevation 0 to 1,500 m at 100% load

Audible noise at
60-100 kVA: 65 dBA at 100% load*; 120-200 kVA: <70 dBA at 100% load*
1 m from unit

Protection class IP20 (optional IP30, IP40, and IPX2 kits available)

*Under 30°C
**342–150 with a linear derating of the load to 30%
Life Is On | Schneider Electric 7
To learn more about the Easy UPS 3S and Easy UPS 3M uninterruptible
power supplies and EcoStruxure IT DCIM, contact your Schneider Electric
representative or visit se.com/ups

About Schneider Electric Schneider’s purpose is to empower all to make the most of our energy and resources, bridging progress and
sustainability for all. We call this Life Is On.

Our mission is to be your digital partner for Sustainability and Efficiency.

We drive digital transformation by integrating world-leading process and energy technologies, end-point to cloud connecting products,
controls, software and services, across the entire lifecycle, enabling integrated company management, for homes, buildings, data centers,
infrastructure, and industries.

We are the most local of global companies. We are advocates of open standards and partnership ecosystems that are passionate about
our shared Meaningful Purpose, Inclusive and Empowered values.

Schneider Electric SE

35 rue Joseph Monier


92500 Rueil Malmaison – France
www.schneider-electric.com

November 2023

©2023 Schneider Electric. All Rights Reserved. Life Is On Schneider Electric is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies.
All other trademarks are the property of their respective owners.

998-20488370_GMA-US_B

You might also like