You are on page 1of 3
EU-Type-Examination Certificate (2) Equipment and protective systems Intended for use in potently ‘explosive atmospheres, Creetive 2014/34EU (2). Conttieate Number ‘TOV GY 17 ATEX 0205070 x (0) forthe equipment Exposion-proof terminal box BXUSIB Series (8) ofthe manufacturer: Warom Technology Incorporated Company (0) Adsress: 'No.855 Baogien Roadsiading Distt, ‘Shanghei- CHINA Order number: 208970 Date of issue: 2017-10-08 (7) The dosign of this equipment or protective system and any acceptable variaton thereto are pected in the schesuls to tis EU-Type-Examination Cerificete and the documents therein refered to. (€) TOV CYPRUS Lt, noted body No. 2261 in accordance with Article 17 ofthe Council Directive of 2OTA/34/EU of February 26, 2014, carles that this equipment or protective system has been ‘ound ta comply withthe Essentisi Health and Safety Requirements relaing to the design and Construction of equipment and protective systems Infended for use in potenaly explosive atmospheres given in Armex Il tothe Directive. The examination and test results are recorded in the confident port No 17 0208970. (8) Compliance withthe Essential Health and Safely Requirements has been assured by compliance wath EN o0079-0:2012/a11:2013 EN 600794:2016 EN 60079-31:2014 (10) 1 te sign “X" Is placed ater the certificate number, it inalotes that the equipment or protective system is subject to spacial conditions for safe use spected inthe schedule io ths certificate. (11) This EU-Type-Examinatin Cerificate relates only to the design, examination and tests of the spectied equipment In accordance te the Directive 2014/34/EU. Further raquremenis of the Directive appy t the manufacturing process and supply ofthis equipment which are not coverod by is corticate. (12) The marking ofthe equipment or protective system must include te folowing: © 2G exabuBene Tsi75 Go retary alin ea Pari es a Ope (3) SCHEDULE (14) EU-Type-Examination Certificate No. TUV CY 17 ATEX 0205970 X (15) Description of equipment “The BXLAIB series explsion-re0f terminal boxes consist n a fameproo enclosure and terminals ‘The sreome re nade of d-csin sininmalo wh conor rot propery. The over fixed the casing with sews. Earthing crews are installed bath inside and outside the enclosure. ‘The enclosure are provided wih: NPT thread and ISO Standard Metric thread ‘The enclosure of exploslon-pt contol station 1s the BXT-W flameproof enclosure with type of protectin "Ex db’ and "Ex tb" The LCIE 11 ATEX 2013 is the older eerticale, Permissible range of ambient temperature 60°C 75/ TOC [60 °C5Tas +40 °C > 15 /T8OC “The degres of enclosure protection according lo EN 60529 Is IP86, ‘dentfication code: gsc by Le casper et quay rem net et quay tar et Teal ederent oie cote 1 HM, MB, WW wu) plo oedema bores OF MOMSEN END aa 206 roa Max. Rated Votage (Vac) 800 Max. Rated Current (A) 400 Warn ‘Tho following varings can be applied an the enclosure: WARNING: Do not open wher energized WARNING: Use fastonere with ied stress > 450 MPa WARNING: Potential electrostatic charging hazard ~ see instructions (16) Test documents are Hated inthe tot report No, 17 0208970. (17). Special condition fr safe use Repair ofthe flameprootjlnis must be made in compliance with the structural speciicatons provided by the manufacturer. Repairs must not be made onthe bass of valves specified I tables 2 3, 4, 5 of EN 60079. Only the suitably cert cable glands can be used for fixing cables. The unused holes must be cosed by the suitably cerifed plugs. Only use cables sutable for 110°C. (18) Essential Health and Safety Requirements ‘No addtional ones,

You might also like