Professional Documents
Culture Documents
SikaGrout®-214 IN
High strength non-shrink pourable cementitious precision grout
PRODUCT INFORMATION
Product declaration ASTM C1107
Chemical base Portland cement, special additives and aggregates
Packaging 30 kg bag
Shelf life 6 months from date of production
Storage conditions The product must be stored properly in undamaged and unopened original
sealed packaging in dry conditions at temperatures between +5 °C and
+35 °C. Protect from moisture, direct sunlight and frost.
1/4
Appearance / Colour Grey powder
Maximum grain size Dmax: 2.36 mm
Density Mixed density : 2.15 kg/L (EN ISO 2811-1)
TECHNICAL INFORMATION
Compressive strength Curing time Compressive strength (ASTM C109)
1 day ~25 N/mm2
3 days ~35 N/mm2
7 days ~45 N/mm2
28 days ~65 N/mm2
Values at water : powder = 0.15, cube size 70.6 mm, curing temperature
+30 °C
Tensile adhesion strength ~2 N/mm2 (28 days, +30 °C) (EN 1542)
Pull-out bond strength Time Pull out bond strength (IS : 2770 Part 1)
7 days ~19 N/mm2
28 days ~20 N/mm2
APPLICATION INFORMATION
Mixing ratio Application Water to powder ratio Quantity of water per
bag
Flowable Water : Powder = 0.15 4.5 L to 4.8 L
to 0.16 (by weight)
Pourable Water : Powder = 0.14 4.2 L
(by weight)
2/4
BASIS OF PRODUCT DATA clean water into a clean mixing container.
2. Stir water slowly with a spiral paddle (< 500 rpm).
All technical data stated in this Product Data Sheet are 3. Add the complete bag of powder into the water
based on laboratory tests. Actual measured data may while stirring slowly.
4. Add balance quantity of water and mix continuously
vary due to circumstances beyond our control.
for 3 minutes to achieve a uniform and lump free
smooth consistency.
FURTHER DOCUMENTS 5. Wait for 1–2 minutes to allow the entrapped air to
escape.
Sika Method Statement : Cementitious grouting of ma-
chine bases and base plates Grout mixer
IMPORTANT
ECOLOGY, HEALTH AND SAFETY Product must be mixed using suitable grout mixing
equipment combined with agitator for large volume
User must read the most recent corresponding Safety mixing.
Data Sheets (SDS) before using any products. The SDS IMPORTANT
provides information and advice on the safe handling, Volume capacity of equipment must be proportionally
storage and disposal of chemical products and con- greater than the volume of material being mixed.
tains physical, ecological, toxicological and other
safety-related data. Note: Equipment trials must be considered to make
sure product can be mixed satisfactory before full
APPLICATION INSTRUCTIONS project application.
SUBSTRATE QUALITY / PRE-TREATMENT 1. Pour the minimum water ratio in the correct propor-
tion into the grout mixer.
Concrete 2. While stirring the water, slowly add the powder to
▪ The concrete must be structurally sound, thoroughly the water.
clean, free from oil, grease, dust, loose material, sur- 3. Add more water within the mixing time up to the
face contamination and materials which will impair maximum allowed until the required consistency is
the grout flow or reduce adhesion strength. achieved.
▪ Laitance, delaminated, weak, damaged and deterior- 4. Mix continuously for a minimum of 4 minutes. For
ated concrete and where necessary unsound con- larger mixes the mixing time must be extended to
crete must be removed by suitable mechanical pre- approximately 6 minutes or as necessary until the
paration as directed by the engineer or supervising grout achieves a lump free smooth consistency.
officer.
▪ Any pockets or holes for structural fixings must also APPLICATION
be cleaned of all debris.
IMPORTANT
Shutter Formwork Do not use SikaGrout®-214 IN for patch repair work or
▪ Where formwork is to be used, all formwork must be overlay in unconfined spaces etc.
of adequate strength, treated with release agent and IMPORTANT
sealed to prevent leakage of pre-wetting water and Avoid application in direct sun and/or strong wind.
grout. IMPORTANT
▪ Ensure formwork includes outlets for removal of the Protect freshly applied material from freezing and
pre-soaking water or use vacuum extraction equip- frost.
ment to remove water.
▪ For manual grout application, a header box or hop- Strictly follow installation procedures as defined in
per must be constructed on one side of the form- method statements, application manuals and working
work so that a minimum grout head of 150–200 mm instructions which must always be adjusted to the ac-
can be maintained during the grouting operation. tual site conditions.
MIXING Pre-wetting
IMPORTANT ▪ The prepared concrete substrate must be thoroughly
Do not add more water than the maximum specified. saturated with clean water for a recommended min-
IMPORTANT imum 2 hours before application of the grout.
▪ The surface must not be allowed to dry within this
Do not use continuous mixing equipment.
time.
IMPORTANT ▪ Before application of the grout, all water must be re-
For large bedding holes and higher gaps or based on moved from within formwork, cavities or pockets
some specific customer requirements, duly washed and the final surface must achieve a dark matt ap-
coarse aggregates of size 6 mm down may be mixed pearance (saturated surface dry) without glistening.
with SikaGrout®-214 IN in the proportion of grout : ag- Placing: Manual application
gregate = 2 : 1 (by weight). Trials are recommended to 1. Apply the material within ~10 minutes after mixing
confirm suitability of aggregates to be used. to take advantage of the expansion properties.
Electric single or double paddle mixer 2. Immediately after mixing, pour the mixed grout into
1. Pour around 80 to 90 % of recommended amount of the header box or hopper ensuring continuous grout
3/4
flow during the complete grouting operation to avoid CLEANING OF TOOLS
trapping air.
Clean all tools and application equipment with water
Placing: Grout pump application immediately after use. Hardened material can only be
▪ For large volume placement, grout pumps are re- mechanically removed.
commended.
▪ Equipment trials must be considered to ensure LOCAL RESTRICTIONS
product can be pumped satisfactory.
Note that as a result of specific local regulations the
Surface finishing declared data and recommended uses for this product
IMPORTANT may vary from country to country. Consult the local
Do not add additional water on the surface. Product Data Sheet for exact product data and uses.
IMPORTANT
Do not over work the surface as this may cause sur- LEGAL NOTES
face discolouration and cracking.
The information, and, in particular, the recommenda-
1. Finish exposed grout surfaces to the required surface tions relating to the application and end-use of Sika
texture as soon as the grout has started to stiffen. products, are given in good faith based on Sika's cur-
2. After the grout has initially hardened, remove form- rent knowledge and experience of the products when
work and trim edges while concrete is ‘green’. properly stored, handled and applied under normal
conditions in accordance with Sika's recommenda-
Cold weather working tions. In practice, the differences in materials, sub-
▪ Consider storing bags in a warm environment and us- strates and actual site conditions are such that no war-
ing warm water to assist with achieving strength gain ranty in respect of merchantability or of fitness for a
and maintaining physical properties. particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
Hot weather working from this information, or from any written recom-
▪ Consider storing bags in a cool environment and us- mendations, or from any other advice offered. The
ing cold water to assist with controlling the exo- user of the product must test the product’s suitability
thermic reaction to reduce cracking and maintaining for the intended application and purpose. Sika re-
physical properties. serves the right to change the properties of its
CURING TREATMENT products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our
▪ Protect exposed grout surfaces after finishing from current terms of sale and delivery. Users must always
premature drying and cracking by curing under water refer to the most recent issue of the local Product
for at least 72 hours. Keep exposed surfaces to a Data Sheet for the product concerned, copies of which
minimum. will be supplied on request.
▪ In cold weather, apply insulated blankets to maintain
a constant temperature to prevent surface damage
from freezing and frost.
SikaGrout-214IN-en-IN-(10-2023)-3-1.pdf