TUGAS PERANCANGAN BERBANTUAN KOMPUTER

1. Cari Datasheet Panel Potovoltaik

2. Hitung 𝑃𝑝𝑣 dari Panel PV tersebut, jika radiasi matahari global (𝐼𝑇 ) = 0,7 𝑘𝑤/𝑚2

Diketahui:
𝑃𝑝𝑣,𝑠𝑡𝑐 = 350 𝑊 = 0,35 𝑘𝑤
𝑁𝑚𝑝,𝑠𝑡𝑐 = 18,1% = 0,181
𝑇𝑐,𝑁𝑂𝐶𝑇 = 45°𝐶
𝜕𝑝 = −0,38%/°𝐶 = −0,0038/°𝐶

𝐹𝑝𝑣 = 1 (𝑎𝑠𝑢𝑚𝑠𝑖 𝑙𝑖𝑛𝑔𝑘𝑢𝑛𝑔𝑎𝑛 𝑠𝑒𝑘𝑖𝑡𝑎𝑟 𝑠𝑒𝑚𝑝𝑢𝑟𝑛𝑎)


𝐼𝑇 = 0,7 𝑘𝑤/𝑚2
𝑇𝑎 = 25°𝐶
𝑇𝑎,𝑁𝑂𝐶𝑇 = 20°𝐶
𝑇𝑐,𝑠𝑡𝑐 = 25°𝐶

Penyelesaian:
𝑖𝑡
𝑃𝑝𝑣 = 𝑃𝑝𝑣,𝑠𝑡𝑐 𝑥 𝐹𝑝𝑣 𝑥 𝐹𝑡𝑒𝑚𝑝 ( )
𝑖𝑡,𝑠𝑡𝑐
𝑇 − 𝑇𝑎,𝑁𝑂𝐶𝑇
1 + 𝜕𝑝 [𝑇𝑎 + 𝐼𝑇 ( 𝑐,𝑁𝑂𝐶𝑇 ) − 𝑇𝑐,𝑠𝑡𝑐 ] 𝜂𝑀𝑝, 𝑠𝑡𝑐
𝐼𝑇 , 𝑁𝑂𝐶𝑇
𝐹𝑡𝑒𝑚𝑝 =[ ]𝑥
𝑇𝑐,𝑁𝑂𝐶𝑇 − 𝑇𝑎,𝑁𝑂𝐶𝑇 0.9
1 + 𝜕𝑝 𝑥 𝑖𝑡 ( )
𝐼𝑇 , 𝑁𝑂𝐶𝑇
45 − 20
1 + (−0,0038) [25 + 0,7 (
0,8 ) − 25] 0,181
𝐹𝑡𝑒𝑚𝑝 =[ ]𝑥
45 − 20 0.9
1 + (−0,0038) 𝑥 0,7 ( )
0,8
𝐹𝑡𝑒𝑚𝑝 = 0,201
0,7
𝑃𝑝𝑣 = 0.35 𝑥 1 𝑥 0.201 ( )
1

𝑃𝑝𝑣 = 0,049245 kw = 49,245 w