Document Title: Function Group: Information Type: Date:


Cylinder head, leakage 211 Service Information 14.04.2020
check
Profile:

Cylinder head, leakage check


Op nbr 21171

999 2124 Sealing plug, 2 pcs


999 6685 Clamp
999 3844 Reducing valve

1. Fit the sealing plugs 2124 in the coolant ducts on the underside of the cylinder head.

Figure 1

1. 999 2124, 2 pcs

2. Fit tools 6685 and 3844.


Immerse the cylinder head in water.
Water temperature: 70 °C (158 °F)
Figure 2

1. 999 3844
2. 999 6685

3. Set the reducing to a pressure of 50 kPa (7 psi).


Keep that pressure for 1 minute.
Air pressure: 50 kPa (7 psi), 1 minute

4. Raise the pressure to 150 kPa (22 psi). Close the valve. Check after a further two minutes, if the pressure drops or if
air bubbles are coming out of the water.
Air pressure: 150 kPa (22 psi), 1 to 2 minutes