You are on page 1of 1

CONSTRUCTION OF TOILET BLOCK FOR

HIGH SCHOOL (GIRLS) FOR 251 TO 500 STRENGTH


UNDER MANABADI :NADU-NEDU PHASE-II IN AP STATE

1) Toilet block is designed for 251 to 500 Strength without water tank.
2) Depending upon the area available the plan may be reworked out.

A
14640
V2 V1 V1 V1 V1

INCINERATOR
TOWEL VENDING

WASH BASINS
ROD MACHINE

GIRLS-
PH W.C./ WC WC WC WC WC WC
V3 CHANGE ROOM 1500x1200 1500x1200 1500x1200 1500x1200 1500x1200 1500x1200
2400x1800
D3 D3 D3 D3 D3 D3

3365
1200

V
D1
GIRLS TOILET
11550x3830
D3 D3 D3 D3 D3
UP WC WC WC WC WC
D1 1500x1200 1500x1200 1500x1200 1500x1200 1500x1200
WASH BASINS

V1 V1 V1 V1
A
RAMP
1:12 TO 1:20-SLOPE PLINTH AREA:62.80 sqm 676 sft FOR GIRLS
DESIGNED BY APEWIDC
PROJECT: //APPROVED//
DRG.NO:
01/MBNN/APEWIDC/TOILET BLOCK/G.FLOOR/
HS-GIRLS/251-500/AD NOTE: Sd-xxxxx
CONSTRUCTION OF TOILET BLOCK FOR
HIGH SCHOOL (GIRLS) FOR 251 TO 500 STRENGTH CHIEF ENGINEER
1. USE VIBRATED REINFORCED CONCRETE OF APEWIDC, VIJAYAWADA.
GROUND FLOOR PLAN UNDER MANABADI :NADU-NEDU PHASE-II IN AP STATE 1
MIX (1:1(2):3) CONFORMING TO IS:456-2000.
2. USE HYSD BARS OF Fe-500 AS PER IS:1786-2008. //TRUE COPY//
REFERENCE: 3. THE STRUCTURE IS DESIGNED FOR GROUND
D1 - DOOR 1 - 1.20 X 2.10 m V2 - VENTILATOR - 2.00 X 0.45 m FLOOR ONLY.
D2 - DOOR 2 - 0.90 X 2.10 m V3 - VENTILATOR1 - 1.50 X 0.45 m 4. FOOTINGS ARE DESIGN FOR
GROUND FLOOR AREA : 62.80 sqm (OR) 676 sft D3 - DOOR 3 - 0.75 X 2.10 m 100,150,200,250,300 kN/sqm
V - VENTILATOR - 3.36 X 0.45 m NOTE : ALL DIMENSIONS EXECUTIVE ENGINEER (D)
V1 - VENTILATOR1 - 2.20 X 0.45 m ARE IN MILLIMETERS NADU-NEDU PHASE-II APEWIDC, VIJAYAWADA.