RMCi – APPLICATION SHEET

…the comfortable Remote Machine Control unit for your test machine

Extend you flexibility by operating your test


application with the DOLI RMCi concept

 +49 (0) 89 202 43 - 0 DOLI ELEKTRONIK GMBH  sales@doli.de


 +49 (0) 89 202 43 - 243 RUDOLF-DIESEL-STRASSE 3  www.doli.de
72525 MÜNSINGEN, Germany REV 18/03/2021
RMCi – APPLICATION SHEET
…the comfortable Remote Machine Control unit for your test machine

RMCi Overview

iCreep

Tensile &
Compression
Standalone
mode (iSAT)

Concrete

Device RMCi1 RMCi8 RMCi7 RMCi6


Suitable for Electric cabinet, All All All
EDCi with desktop
design
Control mode PC, Standalone PC, Standalone PC PC
Display [Pixel] 272x480 272x480
Display type Touchxx Touchxx OLED OLED

No of keys 18 18 21 16
Emergency botton -
Holder type to Magnet Magnet Magnet Magnet
machine Frame

 +49 (0) 89 202 43 - 0 DOLI ELEKTRONIK GMBH  sales@doli.de


 +49 (0) 89 202 43 - 243 RUDOLF-DIESEL-STRASSE 3  www.doli.de
72525 MÜNSINGEN, Germany REV 18/03/2021
RMCi – APPLICATION SHEET
…the comfortable Remote Machine Control unit for your test machine

RMCi Functions (RMCi 8 illustration)


KEY Function Comment
ON Switch drive on. LED is flashing. After drive
amplifier is on, LED is also on
+ OFF Press Digipoti and ON key to switch drive
off. LED is off.

UP Moves crosshead up. LED is on during


movement in this direction.

HALT Halts movement of crosshead. In


standalone mode the key stops the running
test. Test results are shown.
DOWN Moves crosshead down. LED is on during
movement in this direction.

POS MODE Change operational mode of Digipoti from


speed to position control mode.
Both direction LEDs are on.
TURN (All) In speed control mode: increase / decrease
PRESS (RMCi1/8) speed.
In position control mode: increase /
decrease position.
ENTER function in menus or selects a menu
item.
+ HIGH/LOW Activate / deactivate high pressure.
PRESSURE This function must be enabled and
configured in the EDC setup. LED is on if
high pressure is active.
CLOSE/OPEN These four keys operate hydraulic /
GRIPS pneumatic grips. This function must be RMCi8
enabled and configured in the EDC setup.
LEDs are controlled by an external device.

CLOSE/OPEN Operate automatic extensometer arms. This


EXTENSOMETER function must be enabled and configured in
the EDC setup. LEDs are controlled by an
external device.
MOVE XHEAD Operate adjustment of a fixed crosshead.
This function must be enabled and
configured in the EDC setup. LEDs are on if
crosshead is moving.
START Start test (LED on).
HALT Halt running test (LED flashing).
CONTINUE Continue test (LED on).
Function depends on the standalone or PC
application.

 +49 (0) 89 202 43 - 0 DOLI ELEKTRONIK GMBH  sales@doli.de


 +49 (0) 89 202 43 - 243 RUDOLF-DIESEL-STRASSE 3  www.doli.de
72525 MÜNSINGEN, Germany REV 18/03/2021
RMCi – APPLICATION SHEET
…the comfortable Remote Machine Control unit for your test machine

RMCi Functions (RMCi 8 illustration)


KEY Function Comment
RETURN Return to start position. Function depends
on the standalone or PC application.

LINK Function depends on the EDC general data


setup parameter RMC Active Mode. If two
or more RMC are connected, you can set
the behavior of the active RMC.

MULTI: All connected RMCs are active. All


link LEDs are on.
SINGLE: 1. Only one active RMC is
allowed. One link LED is on.
2. All other RMC keys are
disabled (Estop is always active).
3. Press link key of the active
RMC to switch to another RMC.
4. Now all RMC link LEDs are
blinking.
5. Press the RMC link key of the
new RMC.
F1…F3 Function keys are only used in PC Control.
…. Function depends on the PC application. RMCi8
Build in EDCi standalone tests don’t use
(ONLY RMCi6/7) these keys.
TOUCH ENTER function in menus or selects a
SWIP menu item.
Moves cursor up/down or selects a choice
(ONLY RMCi1/8) in parameter menus.

 +49 (0) 89 202 43 - 0 DOLI ELEKTRONIK GMBH  sales@doli.de


 +49 (0) 89 202 43 - 243 RUDOLF-DIESEL-STRASSE 3  www.doli.de
72525 MÜNSINGEN, Germany REV 18/03/2021
RMCi – APPLICATION SHEET
…the comfortable Remote Machine Control unit for your test machine

STANDALONE APPLICATIONS (NO PC)

Universal IOs

DC
Temperature controller

mA
20
Load cell

Sensor plugs 2mV/V


Auto. extensometer
Safety interlock

RMCi8

Amplifier
RMCi8 Sensor plugs TTL

RMCi1
Encoder

 +49 (0) 89 202 43 - 0 DOLI ELEKTRONIK GMBH  sales@doli.de


 +49 (0) 89 202 43 - 243 RUDOLF-DIESEL-STRASSE 3  www.doli.de
72525 MÜNSINGEN, Germany REV 18/03/2021
RMCi – APPLICATION SHEET
…the comfortable Remote Machine Control unit for your test machine

PART LIST
Code Description Part number
RMCi1 EDCi front panel with keyboard unit and TFT touch display 7007503
Suitable for standalone mode

RMCi8 Remote Machine Control unit with 16 keys, emergency-stop, DigiPoti and 1000733
4,3 " TFT touch display, M12 cable interface and 3m cable
Suitable for standalone mode

RMCi7 Remote Machine Control unit with 19 keys, emergency-stop, DigiPoti and 1000505
display, M12 cable interface and 3m cable
Not suitable for standalone mode

RMCi6 Remote Machine Control unit with 15 keys and DigiPoti, M12 cable 1000650
interface and 3m cable
Not suitable for standalone mode

Accessories for RMCi


RMCi-K1 extension cable, 1m, M12-M12, for RMCi and drive box 7007312
RMCi-K3 extension cable, 3m, M12-M12, for RMCi and drive box 7008783
RMCi-K5 extension cable, 5m, M12-M12, for RMCi and drive box 7007313
RMCi-K10 extension cable, 10m, M12-M12, for RMCi and drive box 7007314
RMCi-H Hub for two RMCs incl. cabel 1m (RMCi1, RMCi6, RMCi7,RMCi8) 1000718