TAXIWAY

INSET LIGHTS
Application: Taxiway Center line | Stop Bar
| Intermediate Holding Position
| Runway Entrance Light

The new in-pavement LED lighting products


from Honeywell deliver enhanced energy
savings, reduced maintenance requirements,
and greater life span-optimizing the
operational costs of your airport.

FEATURES AND BENEFITS

MECHANICAL/ ELECTRONICS/ OPERATIONAL/


DESIGN DESIGN PERFORMANCE
Unique 3-light window output Compliant to operate in 3 or 5 steps with Low Maintenance with LED
design for operational flexibility IEC/FAA Constant Current Regulators useful life > 60000 Hours
Modular Top Cover design Auto adaptation operation with Optimized Thermal management for
across all 8 inch Luminaire 50Hz/60Hz Input Frequency Heat dissipation from electronics
No negative slope to prevent sand Near Unity Power factor for Input Surge Protected up to 10kV
or snow buildup in front of prism reduced system losses (FAA Engineering Brief EB-67D)
Designed for high structural stability Luminaire Internal Fault Input Power Factor > 0.95 (FAA
catering to load stresses by aircraft Detection (Fail Open) Engineering Brief EB-67D)
Highly resistant to shock Designed with optical Toe-in
and vibration for curved applications

TECHNICAL SPECIFICATIONS
PARAMETERS VARIANTS COMPLIANCES
Operational current 2.8A to 6.6A Taxiway Centerline (straight and curved section)
FAA AC 150/5345-46
<*13VA per side of Light Stop Bar (straight and curved section) (Current Edition),
Input Power
fixture terminal Engineering Brief No.
Intermediate Holding Position Lights (IHP) EB67
Input Power Factor >0.95
Runway Entrance Lights (RELs) ETL Certified
Operation Frequency 50Hz/60Hz
ICAO A2-12, A2-13, A2-14, A2-15, A2-16, A2-14 ICAO Annex 14 - Volume I
Operational Step 3 step or 5 step (2XREL) EASA Verification of compliance
Dust and Water tightness IP 68 CASA from Intertek
FAA L-852C, L-852D, L-852K
Useful Lamp Life > 60000 hrs TP312

Series circuit PACKAGING EU Declaration of


45W, 65W, 100W
Transformer Rating 260 x 255 x 165 mm Conformity
Packaging size
Temperature (-) 40°C to (+) 55°C (10.24 x 10.03 x 6.5 inch)
IEC 61827
Altitude ≤ 3000m Weight with packing
4.08 kg (9 lb)
(Bidirectional light)
*Note: <22VA primary side with 65W Honeywell make
NTR transformer Weight without packing
3.64 kg (8.03 lb)
(Bidirectional light)

Specifications are subject to change without notice


ACCESSORIES FOR LIGHT UNIT

1 Top cover

Prism 2

3 Prism gasket

4 O-ring for top cover

Optical engine 5

Thermal 6
insulator

Bottom cover
with electronics 7

Cable gland 8

Earth wire Pressure


9 11
assembly release plug

FAA L-823 10
Plug

Specifications are subject to change without notice 2


TECHNICAL DRAWINGS

Side B Beam Direction Side B Beam Direction

Centre Centre
of Curve of Curve

Side A Beam Direction Side A Beam Direction

Right Toe w.r.t Side A Left Toe w.r.t Side A

Specifications are subject to change without notice 3


CHROMATICITIES
0.9
Edi
CIE 1931 plot data
0.8
 Hon
• Hon
0.7
• Hon
FAA Green • Hon
0.6

ICAO/FAA
ICAO Green Yellow
0.5
CIE y

0.4
FAA Red

0.3

0.2
ICAO Red

0.1

0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CIE x
Honeywell Green
Honeywell White
Honeywell Amber
Honeywell Red

Specifications are subject to change without notice 4


LIGHT DISTRIBUTIONS
CAT III TAXIWAY CENTERLINE LIGHTS (ICAO) STRAIGHT WIDE

GREEN YELLOW RED

REQUIREMENT MEASURED REQUIREMENT MEASURED REQUIREMENT MEASURED


Average 200 440.43 Average 200 351.43 Average 200 351.21
Max/Min Max/Min
≤3 1.47 ≤3 1.44 Max/Min Ratio ≤3 1.52
Ratio Ratio

CAT III TAXIWAY CENTERLINE LIGHTS (ICAO/FAA) STRAIGHT NARROW

GREEN YELLOW RED

REQUIREMENT MEASURED REQUIREMENT MEASURED REQUIREMENT MEASURED


Average 200 440.77 Average 200 306.11 Average 200 309.72
Max/Min Max/Min
≤3 1.61 ≤3 1.43 Max/Min Ratio ≤3 1.7
Ratio Ratio

CAT III TAXIWAY CENTERLINE LIGHTS (ICAO/FAA) CURVE

GREEN YELLOW RED

REQUIREMENT MEASURED REQUIREMENT MEASURED REQUIREMENT MEASURED


Average 100 192.94 Average 100 168.89 Average 100 181.82
Max/Min Max/Min
≤3 2.45 ≤3 2.24 Max/Min Ratio ≤3 2.14
Ratio Ratio

Specifications are subject to change without notice 5


PRODUCT CODE ORDERING
TCL - GG - 1 - I - 8 - B - SC - 002 - S - W - 0 - M1 - L2 - 0 - 0
AREA
TCL Taxiway Centerline Light
STB Stop Bar Light
IHP Intermediate Holding Position Light
REL Runway Entrance light
CHANNEL A COLOR
G Green
R Red
Y Yellow
N Neutral/Blank
CHANNEL B COLOR

G Green
R Red
Y Yellow
N Neutral/Blank
INTELLIGENCE
1 Standard
TYPE
I Inset
FIXTURE
08 8” Inset Fitting
12 12” Inset Fitting
SIDES
B Bidirectional
U Unidirectional
CANDELA
SC Candela as per Standard
COMPLIANCE
001 A2-15 002 A2-12 003 L-852C
003 A2-13 004 A2-14 025 L-852D
005 A2-16 016 A2-16/STB 004 L-852K
017 A2-12/STB 018 A2-15/STB
019 A2-14/STB 020 A2-13/STB
022 A2-12/IHP 023 A2-13/IHP
027 A2-14/REL
DIRECTION
S Straight
C Curved
BEAM TYPE
W Wide Beam
N Narrow Beam
L Left Toe
R Right Toe
U Ultrawide
SENSOR SUITE
0 None
C&M
M1 With Hard Failopen
LEADS
L1 One Lead
L2 Two Leads
ARCTIC KIT
0 None
1 Arctic Kit
MOUNTING ASSEMBLY
0 None with Shallow or Deepbase

For more information


Buildings.Honeywell.com
Disclaimer: All tests are done as per
regulatory ICAO Annexure 14D and IEC
Honeywell Building Technologies standards in Honeywell laboratory.
Honeywell International Inc.
Specifications are subject to
1985 Douglas Drive North change without notice
Golden Valley, MN 55422
AGL-TCL-DS I 08/21