You are on page 1of 65
OPERATING AND SERVICE MANUAL exon @ RMS VOLTMETER 3400A | © eee“ | ee __J ms HEWLETT ify PACKARD ‘woove att ha OPERATING AND SERVICE MANUAL (HP PART NO. 03400-90008} MODEL 3400A RMS VOLTMETER SERIALS PREFIXED: 11408" * Appendix C, Manual Backdating Changes, adapts this manual to instruments with serial numbers O9T9A13725, and below, and serials prefixed: $22-, 401-, 528-, and 714 Copyright Hewlett-Packard Company 1965 P.O. Box 301, Loveland, Colorado, 80587 U.S.A, ‘Table of Contents ‘Model 34008, TABLE OF CONTENTS Section Page T GENERAL INFORMATION ......... Le 1-1, Introductions... 00220001) 1 1-3. Description and Purpose 11.1.) 1-1 1-8 Specifications......:....-. 1 1-10, Instrument Identification |). 222. 1-1 1-12, Equipment Supplied... | | 11 I-14. Accessory Equipment Available <<. 1-1 Section Page M INSTALLATION. «2.0... 6-005 21 2-1, Introduction | | 21.) Diliii aa 2-8, Initial Inspection <2 22.21. 21 2-5. Power Requirements | - ilad 2-6, Installation... 1211) 21 2-10, Combining Gase(-hp- Models 1051A OF 10524) ve eee eee ee Bel 2-12, Adapter Frame (-hp- Part No. 5060-0797) vse se eee ee aa 2-14, Repackaging for Shipment... 21. 21 Section Page MI OPERATING INSTRUCTIONS... .. « 3-1 S-1. Introduction... ... ssl. s see 31 Section Vo MAINTENANCE. 6.0... 00-0 ees 5-1, Introduction. 11121 cere 5-8, Test Equipment»... : eer 5-5. Performance Checks «) 1.) 5-7, Accuracy, Linearity, andDC Out- put Cheeks vee eves eee 5-9, Frequency Response Check ; << | 5-10, Input Impedance Check . . <<<: 5-18. Crest Factor Check... 5-14. Output Noise Check <2. 22111 5-15" Adjustment and Calibration Procedures... eee ee eee 5-17, Mechanical Meter Zero |)... | 5-19. Power Supply Checks «2211 5-21, Low Frequency Calibration : << | 5-25, High Frequency Calibration |. | 5-29, Troubleshooting Procedure... | | 5-84, Checking Thermocouples TC401 ‘and TCH2 se eee ee 7 5-37. Thermocouple Replacement » . . 5-89. Checking Photochopper Assembly eter eeerees 5-41, Replacement of Neon Subassembly, “hp- Part No. 1990-0224 5-43. Servicing Etched Circuit Boards Section VI CIRCUIT DIAGRAM G-L, Introduction. 22222222255 6-8, Schematic Diagrams |. 1! 6-6. Parts Location Diagrams... | Section VII REPLACEABLE PARTS...... 2... T-1, Introduction. ..00 2122 T-. Ordering Information > << > 1-6. Non-Listed Parts... ‘Appendix A CODE LIST OF MANUFACTURERS Appendix BB’ SALES AND SERVICE OFFICES ‘Appendix (MANUAL BACKDATING CHANGES LIST OF TABLES 5-3. Controls and Indicators. 211211) aa 8-5. Turn On Procedure... 21211) a4 3-7. Operating Instructions ¢ 11221 a1 8-9. Applications... e211 #1 S611, RMS Value of ACSignais with DC Component se eee eee ee 1 $13, RMS Currents 122222211 5-1 3-15. RMS AC-to-DC Converter 5-1 Section Page IV. THEORY OF OPERATION.......... a1 4-1, Introduction. 2.00002 2202 a1 4-3, General Description, |. 222. “1 4-11, Detailed Description | fla 4-12, Input Attenuator Assembly AL |. 4-1 4-15. Impedance Converter Assembly 2 4-1 4-19. Second Attenuator Assembly A3. . 4-2 4-22, Video Amplifier Assembly Ad... 4-2 4-27. Photochopper Assembly AS, Chopper Amplifier Assembly A6, and Thermocouple Pair (art of A). ee 4-2 4-97. Power Supply’ Assembly A7 | 43 4-40, Regulator Operation... 43 4-48. Neon Lamp Drive Oscillator. + ++ 4-3 Number Page ‘Model 3400A Specifications... .-. . 1-0 Equipment Supplied 2212221 La Accessory Equipment Available. |. << | La Required Test Equipment... 1 1... 5-0 Accuracy, Linearity, and DC’ Ouipat Chock Dates ste eeeccees ce Bl a Number Page 5-8. Frequency Response Check ........ 5:2 Power Supply Checks... 11s... 5-5 Front Panel Symptoms 5-1 ‘Troubleshooting Procedure... |. 5-9 Factory Selected Components <<. | | . 8-16 Replaceable Paris... ee cscs 728 ‘Model 3400 ‘Table of Contents LIST OF ILLUSTRATIONS. Number Page 1-1, -hp- Model $400A RMS Voltmeter... . 1-0 3-1, Model 3400 Controls and Indicators | | 3-0 4-1. Block Diagram . “0 5-1, Accuracy, Linearity an Tost SUD vv seve eevee cess 52 5-2, Frequency Response Test Setup | 111) 5.2 5-3, Input Impedance Test Setup... 111. 5-3 5-4. Crest Factor Test Setup...) 1.1... 8-4 5-5, Troubleshooting Tree 5-8 5-6. Input to Demodulator - 5.9 5-7. Input to Demodulator (feedback Toop open) 5-10 5-8, Outpt of Demodulator (eedhackloopopen) $10 9. Neon Drive Voltage...» + 5-1 3-10. Collector of 602 (feedbacl S12 5-11. Base of Q604 (feedback loop open) 5-12 Number Page 5-12, Base of Q601 (feedback loop open). . . 5-13 6-1." Input Attenuator A1, Impedance Converter A2, and Second Attenuator AS Schematic and Parts Location Dia eee Tere 6-8/6-4 Video Amplifier A4, Schematic and Parts Location Diagram . . 6-5/6-6 Photochopper Assembly AS, Chopper ‘Amplifier Assembly A8, and ‘Thermocouple pair Schematic and Parts Location Diagrar 6-1/6-8 Power Supply AT, Scheu and Parts Location Diagram . , , . 6-9/8-10 Modular Cabinet seve vss cees 12 w Section I Model 34004 Table 1-1, Model S400A Specifications VOLTAGE RANGE: 1 mV to 800 V full scale, 12 ranges. DB RANGE: ~72 to +52 dBm (0 dBm e002). FREQUENCY RANGE: 10 Hz to 10 MHz. mW in RESPONSE: Responds to rms value (heating value) of input signal, METER ACCURACY: | % of Full Seale (209C to 3000)* 10H2_50Hz 1MH2 2MH2 3MH2z_10MHz 25% [art [ a2 [ ast AC-to-DC CONVERTER ACCURACY: % of Full Seale (20°C to 80°C)* 10H S0H2 1Mie 2MHz $MHe 10MH2 38% | 20. 753 | 5% OUTPUT: Negative 1 V de into open circuit for full-seale deflection, proportional to meter deflection; 1 mA maximum; nominal source ‘impedance 10002. OUTPUT NOISE: <1 mV RMS. CREST FACTOR: (ratio of peak-to-rms ampli- ‘tude of input signal): 10:1 at full scale (excent ‘where limited by maximum input), inversely proportional to meter deflection (c.g. 20:1 at hhalf-seale, 100:1 at tenth-scale). INPUT IMPEDANCE: 0,001 V to 0.3 V range; 10 MA shunted by <50 pF: 1.0 V to 300 V range; 19 MA shunted by <20 pF. AC-coupled Input. AC OVERLOAD: 30 dB above full seale or 800 V peak, whichever is less, on each range. MAXIMUM DC INPUT: 600 V on any range. RESPONSE TIME: For a step function, <5 seconds to respond to final value POWER: 115 or 230 V 210%, 48 to 440 Hx. approximately 7 watts. WEIGHT: Net 71/4 lbs. (8, 3kg); shipping 10 tbs, (ke). OVERALL DIMENSIONS: 6 1/2" high: 5 1/8" wide 1111/16" deep, “Temperature Coefficient: £0, f over range of 09C to 20°C and 30°C to $5°C, 10 Model 34004 Section T SCOPE OF MANUAL ‘This manual contains the information necessary for oper- ating and servicing the standard Model 3400A RMS Voltmeter ‘and the Model 3400A/Option 01 RMS Voltmeter (DB scale uppermost). SECTION I GENERAL INFORMATION 1-1. INTRODUCTION. number on your instrument does not agree with those fon the title page af this manual, change sheets supplied ‘with the manual will define the differences between your 1-2, This section contains general information about instrument and the Model 3400A described in this man~ the Model 3400A RMS Voltmeter (Figure 1-1). In- al. Some serial numbers may have a lolter separating cluded are: description of Instrument, purpose, in- the two sections of the number. This letter indicates strument identification, equipment supplied and the country in which the instrument was manufactured. accessory equipment available, Also included is a table of instrument specifications, 1-12. EQUIPMENT SUPPLIED. 1-3. DESCRIPTION AND PURPOSE. 1-19, ‘The equipment supplied with each Model 34008 ig Listed and described in Table 1-2. 1-4, ‘The Model 34004 RMS Voltmeter measures the actual root-means-square (RMS) value of ac voltages Table 1-2, Equipment Supplied between 100 microvolts and 300 volts. Frequency range is from 10 Hz to 10 MHz. Full scale IDENTIFICATION on . measurements of nonsinusoidal waveforms with crest NUMBER | Quantiry | pEscrIPTion factors (ratio of peak voltage to rms voltage) of 10 can be made. 101104 1 ‘Adapter (BNC to ual banana jack) 1-5. Ac voltages are measured with a specified full- scale accuracy of 21% from 50 Hz. to 1 MHz, 22% 8120-1348 1 Power Cord from 1 Miz to 2 Milz, £3 from 2 Milz to 3 MHz, and 5% from 10 Hz to 60 Hz and 3 Mile to 10 Miz. (08400-90008 1 [operating and ‘Asingle front panel control selects one of 12 voltage Service Manual or decibel ranges. 1-14. ACCESSORY EQUIPMENT AVAILABLE. 146, ‘The Model 340A crest factor rating is 10:1 ‘which enables full scale readings for pulses which 1-15, ‘The accessory equipment available is listed have 1% duty eyele, At 1/10th of full scale, pulse in Table 1-3. For further information contact your trains with 0, 01% duty eyele (100:1 erest factor] can _jgcal -hp~ Silles and Service Office. (See Appenaix B be accurately measured. for office locations.) 1-7. ‘The Model 84004 provides a de output which is proportional to the front panel meter reading. By Table 1-3, Accessory Equipment Available Using this voltage to drive auxiliary equipment, the SDeeESICATION Model 3400A functions as an rms ac-to-de converter. pa DESCRIPTION 105088 Cable (Male BNC to male 1-8, SPECIFICATIONS saremietueieel TH001A Cable (Male BNC to dual 4-9, ‘Table 1-1 contains the specifications for the ‘banana plug, 45 inches) Mode! 34004. 110028 ‘Test Lead (dual banana plug to alligator clips, 60 inches) Pamela ere arid 710088 "Test Lead (dual banana plug to IDENTIFICATION. probe andalligator elip, 60 in 1-11. Hewlett-Packard uses a two-section serial aum- 8A Current Probe e@ ber. If the first section (serial prefix) of the serial Model 24004 SECTION I Section INSTALLATION 2-1. INTRODUCTION 2-2, This section contains information and instructions necessary for installation and shipping of the-hp- Model 340A RMS Voltmeter. Included are initial inspection procedures, power requirements, installation Infor- Imation, andinstructions for repackaging for shipment, 2-3. INITIAL INSPECTION. 2-4, The -hp-Model 3400A RMS Voltmeter received a ‘careful mechanical and electrical inspection before shipment. As soon as the Model 3400A Is received, verify that the contents are intact and as ordered, Although the instrument should be free of mars and scratches and in perfect electrical condition, t should be inspected for any physical damge which may have been incurred in transit. Also test the electrical performance of the instrament using the procedures given in paragraph 5-5. If any physical damage or electrical deficiency is found, refer to the warranty fn the inside front cover of this manual. Should shipping of the instrument become necessary, refer {0 paragraph 2-14 for repackaging and shipping instructions 2-5. POWER REQUIREMENTS 2-6. ‘The Model 9400A can be operated from any ac Source of 115- or 280~ volts (+10"¥), at 48 to 440 cycles. With the instrument disconnected from the ae power Source, move the slide switeh (located on the rear nel) until the desired line voltage value appears, The ac line fuse is 2 0.25 amp, fast blow type for U5 oF 230-volt operation, Power dissipation is approxi- mately 7 watts, 2-7. The Model 3400A is equipped with a three-prong Power cord. To protect operating personnel, it is hecessary to preserve the grounding feature of this plug when using a two contact ac outlet, Use a three Prong to ¢wo-prong adapter and connect the green pigtail lead on the adapter to ground, 2-8. INSTALLATION, 2.8. The Model 34004 is a submodular unit suitable for bench top use, However, when used in combination with other submodular units it ean be bench and/or rack mounted. The -hp- combining case and adapter frame are designed for this purpose. 2-10, COMBINING CASE (-hp~ Modeis 10518 or 10524), 2-11. ‘The combining case is a full-module unit which accepts various combinations of submodular unis, Being a full-module unit, it can be bench or rack mounted and is analogous to any full-module instru 2-12, ADAPTER FRAME (-hp- PartNo. 5060-0797) 2-13. ‘The adapter frame is a rack frame that accepts ny combination of submodular units. Tt ean be rack mounted only. For additional information, address inguivies to your -hp- Salesand Service Office, (See Appendix B for office location.) 2-14, REPACKAGING FOR SHIPMENT. 2-15. ‘The following paragraphs contain a general guide for repackaging for shipment, Refer to para- graph 2-16 if the original container Is tobe used;2-17 It is not. If you have any questions, contact your local -hp- Sales and Service Orfiee, NOTE Ifthe instrument is to be shipped to Hewlett-Packard for service oF repair, attach a tag to the instrument identifying the owner and indicate the service or repair to be accomplished; Include the model number and full serial number of the instrument, In any correspondence, identify the Instrument by model number, serial number, and serial number prefix 2-16. If original container is to be used, proceedas follows: a. Place instrument in original container ifavail- able. If original container is not available, one ccan be purchased from your nearest -hp- Sales and Service Office b. Ensure that the container is well sealed with strong tape of metal bands, 2-17. original container is not to be used, pro- ceed as follows: 4. Wrap instrument in heavy paper or plastic before placing in an inner container, b. Use packing material around all sides of Instrument and protect panel face with cardboard strips. ©. Place instrument and inner container in a heavy carton or wooden box and seal with strong tape or metal bands, 4. Mark shipping container with “DELICATE INSTRUMENT," "FRAGILE, " ete a4 Section II ‘Model 34004, Direct reading meter: de meter which indicates rms voltage level of input signal. ‘Mechanical zero adjustment: screwdriver adjue*ment for zero.f divect reading meter, LINE ON pilot lamp: neon lamp which indicates when power is applied instrument and power switch Is ON, Power switch: two-position toggle switeh which applies 115- or 230-volts ac to instrument. RANGE switch: 12-position rotary switch which selects various attenuation ranges Available within Model $4004. INPUT connector: BNC jack which enables application of input signal to instruments measuring circuits. 1 10. 115/230-volt switch: two-position slide switch which sets instrument to operate from either 8 115- oF 280-volt ac source. Inpat power Jack: three-prong jack which enables applicationof line voltage to instru- ments power supply circuits, 115V/230¥ .25A FUSE: 0.25 ampere fuse whichprovides protection against Line voltage DC OUT jack: telephone-type jack which pro- vides negative 1-volt de out at full scale de- fection, output is proportional to meter de- flection, Output impedance is 1000 ohms. telephone type plugfor the DC OUT jack may bbe purchased under -hp- Part No. 1251-0067. Figure 9-1 Model $4004 Controls and Indicators Model 34008 Section I SECTION III OPERATING INSTRUCTIONS mation necessary for the operation of the -hp~ Model 3400A RMS Voltmeter. This section contains identi- fication of controls and indicators, turn-on pro= cedures, and operating instructions. Also included isa discussion of the applications for the Model 400A. 3-3. CONTROLS AND INDICATORS. 8-4. Each operatingcontrol, connector, andindieator located on the Model S400A 1s identified and described in Figure 3-1. The description of each component is keyed to an illustration of that component which is, included within the figure. 3-5. TURN ON PROCEDURE. 3-8, Toturnonthe Model 34004, proceed as follows: a. Set 116/280 switch (7, Figure 3-1) to correct position for input line voltage. »b. Apply ac voltage to Model S400A by plugging power cord into input power jack (8) ae receptacle. ©. Operate power switch (4) to ON; ensure that LINE indicator (3) Lights. NOTE Allow five minutes for the Model 340A to warm up and stabilize before making & reading. 3-7, OPERATING INSTRUCTIONS. DO NOT MEASURESIGNAL ABOVE, 80 VOLTS WITH 10 TO 1 CREST FACTOR. OTHERWISE, THE MAXI- MUM INPUT RATING (800 VOLTS PEAK) WILL BE EXCEEDED, WHEN MEASURING SIGNALS UP TO 80 VOLTS RMS WITH A 10 T01 CREST FACTOR, USE THE BNC TO DUAL BANANA JACK, ACCESSORY I0110A, SUPPLIED WITH THE INSTRUMENT, OR OTHER INPUT TEST LEADS AND’ CONNECTIONS THAT WILL WITH- STAND THE MAXIMUM INPUT OF 800 VOLTS PEAK. 3-8. To operate the Model 3400A as an rms volt- meter proceed as follow: a. Attach test lead toINPUT connector (6, Figure 8:1), (See Table 1-8 for a listof test leads available.) b. Set RANGE switch (5) to 900 VOLTS position. WHEN MEASURING ANAC SIGNAL SUPERIMPOSED ON A DC LEVEL, ALWAYS SET THE RANGE SWITCH TO THE 200 VOLT PosITIoN. AHIGH VOLTAGE TRANSIENT DUE ‘TO THE APPLICATION OF A DC VOLTAGE WILL DAMAGE THE INPUT CIRCUITRY. Connect test lead to point to be measured, 4. Rotate RANGE switch counterclockwise until ‘meter (1) indicates on upper two thirds of scale. 3-9. APPLICATIONS. 1-10. The Model 3400A can be used in conjunction ‘with other test instruments to measure the rms value of ac signal with a de component, measure rms current and act as an rms ac-to-de converter. For additional information on special applications, contact your -hp- Sales and Service Office. 8-11, RMS VALUE OF AC SIGNALS WITH DC COMPONENT. 3-12. Since the S400A is an ae device it will measure only the rms value of the ae component, If it 48 nec essary to include the rms value of the de component when measuring a signal use a -hp-Model 412A DC Voltmeter to measure the de component. Substitute the reading from the Model 412A and Model 3400A in the following formula: The ac signal up to G00V peak) may be superimposed on a de level of up to 600 V. {fe tve,? eo * ae 3-18. RMS CURRENT. 3-14, To measure rms current, use an -hp~ Model 456A, AC Current Probe. This probe clips around the current conductor and provides an output voltage that 1s proportional to the current being measured, Using this method, rms currents of one milliampere to one ampere ean be measured. 3-15, RMS AC-TO-DC CONVERTER. 3-16, Since the Model $400 is provided with a de output (10, Figure 3-1) which is proportional to the meter deflection, it can be used as a linear tme ac to de converter. “The de output can be used to drive a -np- Model 3440A Digital Voltmeter for high resolu tion measurements and/or a Mosely Model 680 Strip Chart Recorder. External loading does not affect the meter accuracy'so that both the meter and de output can be used simultaneously. A plug for DC OUT Jack may be purchased under -hp- Part No. 1251-0067, at i Model $4008, Section IV SECTION IV THEORY OF OPERATION 4-1. INTRODUCTION This section contains the theory of operation of the Model 3400A RMS Voltmeter. Included is. a general and detailed description of the theory of operation. 4-3, GENERAL DESCRIPTION. 4-4. ‘The Model 3400A comprises two attenuators, an impedance converter, a video amplifier, a photo: conductor chopper (modulator/demodulator), chop- per amplifier, an emitter follower, a thermocouple pair, and a direct reading meter. ‘(See Figure 4-1.) 4-5. A signal being measured with the Model 34004, 4s applied to input attenuator A through the INPUT jack, located on the Model 340A front panel. The input attenuator has an input impedance of over 10 megohms and provides two ranges of attenuation, ‘The output of the input attenuator is applied to imped ance converter A2, The impedance converter is a non-inverting unity voltage gain amplifier, Tt presents 4 high impedance to the input signal and provides a ow impedance output to drive the second attenuator AB. The second attenuator provides 6 ranges in a 1, 8, 10 sequence. The two attenuators are switched to provide 12 ranges of attenuation. 4-6. The output of the second attenuator is amplified by video amplifier Ad. ‘The video amplifier Is a wide- band, five stage amplifier. The overall gain of the video amplifier 18 controlled by an ac feedback loop. The ac output of the amplifier is applied to TC404; one of the thermocouples of the thermocouple pair. 4-1, ‘The de output of TC401 is modulated by mod- ulator AS, The modulator comprises two photocells which are alternately illuminated by two neon lamps ‘which in turn are controlled by the oscillator located ‘on power supply assembly AT. The output of the ‘modulator is a square wave whose amplitude is pro- portional to the de input level 4-8. The square wave output of the modulator is amplified by chopper amplifier A6. The chopper amplifier is a high gain ac amplifier. Its output is applied to demodulator AS. ‘The demodulator outpat is.a de level whose magnitude is proportional to the amplitude of the ac input, ‘The demodulator output is applied to two direct coupled emitter followers. The emitter follower is used to make the impedance trans formation from the high impedance output of the de- modulator to the low impedance of the direct reading meter M1 and TC402; the second thermocouple of the thermocouple pair. 4-9, The thermocouple pair TC401 and TC402 acts a8 a summing point for the ac output of the video amplifier A4 and the de output of the emitter followers. ‘The difference in the heating effect of these voltages is felt as a de input to modulator AS. This difference ‘input is amplified and is fed to TC402 and to meter Mi. This amplified de voltage represents the rms value of the ac signal applied at the INPUT jack. By using two "matched" thermocouples and measuring the difference, the output to the modulator will be Linear, Using two thermocouples also provides temperature stability. 4-10. ‘The de voltage driving meter M1 is also available at the DC OUT jack, located at the rear of the Model 3400. 4-11. DETAILED DESCRIPTION. 4-12, INPUT ATTENUATOR ASSEMBLY A. 4-13. ‘The input attenuator assembly is a eapacitive- compensated attenuator which provides two ranges of attenuation for the 12 positions of the RANGE switeh, See input aitenuator schematic diagram illustrated on Figure 6-1, 4-14, When the RANGE switch is positioned to one of the six most sensitive ranges (.001 to .8 VOLTS), the attenuator output voltage is equal to the input voltage. When the RANGE witch is positioned to one of six highest ranges (1 to 300 VOLTS), the input sig~ tal is attenuated 60 dB (1000: 1 voltage division) by the resistive voltage divider consisting of R101, R103, and R104, ‘Trimmer C102 is adjusted at 100 kiiz, and R104 is adjusted at 400 Hz to provide constant atten uation over the input frequeney range. 4-15, IMPEDANCE CONVERTER AS: MBLY A2, 4-16, ‘The impedance converter assembly utilizes a anuvistor tube cathode follower cireuit to match the high output impedance of the input attenuator to the low input impedance of the second attenuator. The cathode follower circuit preserves the phase relation- ship of the input and output signals while maintaining 2 gain of unity, See impedance converter assembly Schematic diagram illustrated on Figure 6-1 4-17, The ac signal input to the impedance converter is RC coupled to the grid of cathode follower V201 ‘through C201 and R203, The output signal is devel- oped by Q201 which acts as a variable resistance in the cathode circuit of V201. The bootstrap feedback from the cathode of V201 to R203 Increases the effective resistance of R203 to the input signal, This prevents R203 from loading the input signal and pre- Serves the high input impedance of the Model 2400A, ‘The gain compensating feedback from the plate of ‘V201 to the base of Q201 compensates for any varying ain in V201 due to age or replacement, 4-18, Breakdown diode CR201 controls the grid bias 4a Section 1V voltage on V201 thereby establishing the operating point of this stage. CR202 and R211 across the base- emitter junction of Q201 protects Q201 in the event of a failure in the +75 volt power supply. Regulated de is supplied to V201 filaments to avoid inducing ae hum in the signal path. This also prevents the gain of V201 ‘changing with line voltage variations. 4-19, SECOND ATTENUATOR ASSEMBLY A3, 4-20, The second attenuator is a resistive divider which attenuates the ac input signal while maintaining a low impedance output for the following amplification Stages, See second attenuator assembly schematic Giagram illustrated in Figure 6-1. 4-21, ‘The ac input signal is applied to a precision resistance voltage divider consisting of R902 through R312. These resistors are arranged to give six ranges of attenuation at 10 dB per range. The six ranges of the second attenuator combined with the two ranges of the input attenuator make up the 12 ranges of attenuation (0.001 to 300V), Trimmer capacitor (€303 (10 MHz 0.3V ADJ) provides an adjustment for frequency response at the higher frequencies, 4-22, VIDEO AMPLIFIER ASSEMBLY A\ 4-23, ‘The video amplifier functions to provide con- stant gain to the ac signal being measured over the entire frequency range of Model 3400A. See video amplifier assembly schematie diagram iMustrated on Figure 6-2. 4-24, ‘Tho ac input signal from the secondattenuator 4s coupled through C402 to the base of input amplifier Q401. QHO1, a class A amplifier, amplifies and in- verts the signal which is then direct coupled to the base of bootstrap amplifier Q402. The output, taken from Q402 emitter is applied to the base of Q403 and fed back to the top of R406 as a bootstrap feedback. ‘This positive ac feedback increases the effective ac resistance of R408 allowing a greater portion of the signal to be felt at the base of Qi02, In this manner, the effective ac gain of Q401 is increased for the mid band frequencies without disturbing the static operating voltages of Q401. 4-25, Driver amplifier Q403 further amplifies the fac signal and the output at Q403 collector is fed to the base circuit emitter follower Q404. The feedback path from the collector of Q403 to the base of Q402 through C405 (10 MHz ADJ) prevents spurious oscil~ lations at high input frequencies. A de feedback loop exists from the emitter circuit of Q408, to the base ‘of Q4OL through R425, This feedback stabilizes the (QUO1 bias voltage. Emitter follower QiO4 acts as a driver for the output amplifier consisting of Q405 and 06; a complimentary pair operating as a push-pull amplifier, The video amplifier output is taken trom the collectors of the output amplifiers and applied to thermocouples TCA0I. A gain stabilizing feedback is @eveloped in the emitter eireuits of the output ampli- fiers, This negative feedback is applied tothe emitter of input amplifier Qi01 and establishes the overall gain of the video amplifier. 42 ‘Model 24004, 4-26, ‘Trimmer capacitor C405 is adjusted at 10 Miz {or frequency response of the video amplifier. Diodes ‘CR&O2 and CR406 are protection diodes which prevent voltage surges from damaging transistors. in the video amplifier, R401, CR407, and CR408 are ‘temperature compensating diodes to maintain the zero signal balance condition in the output amplifier over the operating temperature range. CR4Q3, a break- down diode, establishes the operating potentials for the output amplifier, 4-27. PHOTOCHOPPER ASSEMBLY AS, CHOPPER ‘AMPLIFIER ASSEMBLY A8, AND THERMO- ‘COUPLE PAIR (PART OF AW]. 4-28, ‘The modulator/demodulator, chopper ampli- fier,” and thermocouple pair form a servo loop which functions to position the direct reading meter M1 to the rms value of the ac input signal. See modulator/ demodulator, chopper amplifier, and thermocouple pair schematic diagram illustrated in Figure 6-3. 4-29, ‘The video amplifier output signal is applied to the heater of thermocouple TC401. This ae voltage causes a de voltage to be generated in the resistive portion of TC401 which is proportional to the heating effect (rms value) of the ac input. The de voltage is applied to photocell V501. 4-30, Photocells V501 and V502 in conjunction with neon lamps DS501 and D$502 form « modulator cir ceait, The neon lamps are lighted alternately between 90 and 100 Hz, Each lamp illuminates one of the photocells, DS501 illuminates V501;DS502 illuminates 'V502. When a photocell is illuminated it has a low resistance compared to its resistance when dark. ‘Therefore, when V501 is illuminated, the output of thermocouple TC401 is applied to the input of the chopper amplifier through V501. When V502 is i1lumi- nated, a ground signal is applied to the chopper amp- fier, “The alternate illumination of VS01 and V502 modulates the de input at a frequency between 90 and 100 Hz, ‘The modulator output is a square wave whose amplitude is proportional to the de input level. 4-31, The chopper amplifier, consisting of Q601 through (605, is a high gain amplifier which amplifies the square wave developed by the modulator. Power supply voltage variations are reduced by diodes CR601 thru CR603. The amplified output is taken from the collector of Q503 and applied to the demodulator through emitter follower Q604. 4-32, ‘The demodulator comprises two photocells, ‘V503 and V504, which operate in conjunction with S501 and DS502; the same neon lamps usedto illumal- rate the photocells in the modulator. Photocells V503 land V504 are illuminated by DS501 and DS502, res- peetively. 4-28. ‘The demodulation process is the reverse of the modulation procese discussed in Paragraph 4-30. ‘The output of the demodulator is a de level whieh is, proportional to the demodulator input. The magnitude And phase of the input square wave determines the magnitude and polarity of the de output level. This de ‘output level is applied to two emitter follower output stages. Modet 34008 4-34, ‘The emitter follower is needed to mateh the high output impedance of the demodulator to the low input impedance of the meter and thermocouple cir- cults, ‘The voltage drop across CR604 in the collec- tor circuit of Q805 Is the operating bias for Q604. ‘This fixed bias prevents Q605 failure when the base voltage is zero with respect to ground. 4-85, ‘The de level output, takon from the emitter of Q606, is applied to meter MI and to the heating clement of thermocouple TC402, The de voltage de- veloped in the resistive portion of TC402 is effectively subtracted from the voltage developed by TC401. The Input signal to the modulator then becomes the differ- tence in the de outputs of the two thermocouples. When the difference between the two thermocouples becomes zero the de from the emitter followers (driving the meter) will be equal to the ac from the videoamplifier. 4-36. Noise on the modulated square wave is sup- pressed by feedback [rom emitter of Q606 through (C807 and C808 to the resistive element of TC402. 4.97, Pow SUPPLY ASSEMBLY AT. 4-88, ‘The power supply assombly provides de oper= ating voltages for the tube andtransistors used in the Modet 34008, See power supply assembly sehematle diagram illustrated on Figure 6-4 4-59, Either 115 or 230 volts ac is connected to the primary of power transformer Tl through fuse FY and the POWER switch SI. Switch $2 (slide switch on rear panel) connects T1 primary windings in series for 250-volt operation or in parallel for 115-volt oper- ation, Neon lamp DSI lights to indicate LINE power ‘ON when ac power is applied and 81 is closed. 4-40, REGULATOR OPERATION. 4-41, ‘The series regulator acts as a dynamic vari~ able resistor in series with the power supply output. ‘A control amplifier senses changes in the output volt= age by comparing the output with a fixed reference voltage. The control amplifier then supplies any out~ put voltage changes to the driver transistor, which in turn changes the resistance of the series regulator to oppose the change in output vottage. Diodes CR704, CRTI3 and CRI06 across the base emitter junction of the series regulator provide overload current protection. Section IV 4-42, 415 VOLT SUPPLY. 4-43. The +15 volt supply consists of a full-wave rectifier (CR701 and CR702) whose output is filtered by CIA and C1B and regulated by series regulator Qi. ‘The #75 volt supply provides regulated +75 volts which is used as the plate supply voltage for V201. Voltage variation from tho output is felt at Q702 base circuit through C704, RT15, and RT16, ‘The C703 and R708 network provides phase correction for power supply Stability. The regulation circuitry is in the negative leg of the +75 volt supply, and uses the -17.5 volt supply as a reference, 4-44, -17.5 VOLT SUPPLY. 4-45, ‘The regulated -17.5 volt supply consists of a full-wave rectifier (CR711, and CR712) whose output is filtered by 7108 and C107 and regulated by Q2. Breakdown diod 2RT1S provides reference voltage at the base of Q. 1. Regulation operation is the same described in Parag, ~ph 4-41, 4-48, -6.8 VOLT SUPPLY. 4-47, ‘The regulated -6.3 volt supply consists of a fave rectifier (CR716 and CRT17) whose output is filtered by C2 and regulated by Q8. Emitter follow- er Q105 is connected to the -17. 5 volt supply which provides a reference for the -6. 3 volt supply. Series regulator Q3 acts as a dynamic variable resistor in series with the output to oppose changes in output voltage. 4-48, NEON LAMP DRIVE OSCILLATOR. 4-49, The neon lamp drive oscillator consists of transistor Q108, diode CR718, resistors R701, R702, R712, RIS, and capacitor C711. Transistor Q706 is held on (conducting) by the base bias developed at the junction of R712 and CR718. ‘The collector current ‘of Q106 charges up capacitor C711 through R101 or 702 depending upon the illuminated neon lamp onthe Chopper Amplifier Assembly AB. When the capacitor reaches a sufficient charge to fire the dark neon lamp, the illumination of the neon lamps alternate and the capacitor discharges through the previously dark neon amp. With the previously dark neon lamp illuminated, the capacitor charges up in the opposite direction until firing the previously illuminated neon lamp. ‘The eycle described above repeats at a frequency of 90 to 100 He as determined by the RC time constants of RTOLand C71, and R702 and C711. 43 Seetion V Table 5-1, Required Test Equipment Modet 34004 INSTRUMENT |” pequineD CHARACTERISTICS se RECOMMENDED woe DC Voltmeter | Accuracy 0.1 Ril seale Performance Checks | “hp- Mods) 4408/8408 Voltage Hang! 1oniV fo 00V | AgjustmentandCatbrtion | “Digtat Votmeter Votmetor ] Votage Range: 1m to S00 nme | Pestormance Checks | “hp- Model 1905 VoI™ Trowbloshoating Supa Tay av Agjustinentandcabrtion | “Oselator Frequency Response: 0.25% Troubleshooting (Shrandseal) Osciioscope | sensitivity 0,005 v/em ‘ajastment ana Calioaton | “hp Moget 104/ Banca to 20 de Troutlesoaing ‘oan tib0A Pile Pals Wit Posformance Cheake | pe Mode 2144 Fresuency | Range: 250 fo 1000 ie Performance Checks | -Ap-Moaet 52551, Tine herve Thee Peak Votiage Range; 0.5v10000V | Pesformance Checks | tps model 4106 Tesponding | Meeuracy si fo seale MVoumeter Tyeraye | Votiage Range: 0,001 0 200 | Adjustment andaibration | “hp afoast 4008/50 Responding Accuracy: 1'b full scale ‘Troubleshooting. Voltmeter Volmter Gave) Ouipa 8 mA of current wto100a | Tooableshooting “hp- afodel 4108 DG Sip” | Olin Rangel co 10 actu Tube eee Votimeter Resistor | 200K, metal Performance Checks | -hp- Past Wo, 0767-0782 Tesisior | 400 KO, meta im Troubleshooting hye Par No, 0767-0827 Capctor 2a Troubleshooting ~hp- PartNo, 0780-0060 Sow Fecahra | Resistor tved comp 00289) Performance checks | “hp. Mode! 110465 fdayter 106 to Dua Banana Performance Ghecks | pe Model 110184 Tatenior | 18 pin programmatie Troubleshooting “hp- PartNo, 5060-6088 Douce Model 3400 Section V SECTION V MAINTENANCE 5-1, INTRODUCTION. 5-2. This section contains the information necessary for maintenance of the Model 8400A RMS Voltmeter, Included are performance checks, adjustment and calibration procedures, andtroubleshooting procedures. 5-3. TEST EQUIPMENT. 5-4, Thetest equipment required forthe maintenance of the Model 34004 is listed in Table 5-1. If the re- commended model is not available, use any substitute that meets the required characteristics. 5-5. PERFORMANCE CHECKS 5-6, The Performance Checks are in-cabinet tests that compare the Model $400A with its given speclfi- cations. ‘These checks may be used for incoming inspection, periodic maintenance, and for specifica tion checks after a repair. A Performanee Check ‘Test Card is provided at the end of this section for recording the performance of the instrument during the Performance Checks. The card may be removed from the manual and used as a permanent record of the incoming inspection or of a routine performance check, If the instrument fails to mect any of its specifications, perform the Adjustment and Cal- Ibration Procedures outlined in Paragraph 5-15, NOTE Allow a 30-minute warmup period before ‘making performance checks. During the performance checks, periodically vary ‘the Model 3400 line voltage +10% with a power line transformer to assure that the instrument operates correctly at various ac line voltages, ACCURA LINEARITY, AND DC OUTPUT 5-8. The accuracy, linearity, and de output test set- up is ilustrated in Figure 5-1. A Voltmeter Calibrator chb- Model 738B and a DC Voltmeter -hp- Model 3440/3443A) are required for this test. . Connect test setup illustrated in Figure 5-1. b, Set Model 3400A RANGE switch to 0.001 position. c. Adjust Voltmeter Calibrator for 0.001 volt, rms 400 Hz output; set the DC Voltmeter to measure 1 volt, If Model $400A does not indicate within values listed under"meter reading’ in Table 5-2, perform low frequency calibration procedure, Paragraph 5-21. Record 34008 readings. eDe output as indicated on de voltmeter should be within values listed under "S400A DC output" in Table 5-2. Continue to check accuracy, linearity, and de output using Table 5-2. Table 5-2. Accuracy, Linearity, and DC Output Check Data VOLTMETER 34008 3400A METER 3400 De CALIBRATOR VOLTAGE READING. OUTPUT ‘OUTPUT (¥) RANGE (V) Ww wy 0.001 10,.000890 to 0.00101 0.992 to 1.008 0.003 0.00287 to 0, 00803 0, 942 to 0.957 0.01 (0, 00980 to 0, 0101 0,992 to 1.008 0.03 0.0297 to 0.0303, 0,942 to 0.957 on 10,0990 to 0. 101 0,992 to 1,008, 0.3 0,297 to 0. 303 (0,942 to 0.957 Lo 0.990 to 1,08 0,992 to 1,008 0.9 0.88 to.0.81 0.892 to 0. 908 0.8 0.79 to 0.81 0.792 to 0, 808 0.7 0.69 to 0.71 0, 692 to 0. 708 06 0.59 to 0.61 0, 592 to 0, 608 0.5 0.49 to 0. 51 0.492 to 0,508 0.4 0.39 to 0.41 0, $92 to 0. 408 0.3 0.29 to 0.31 0,292 to 0. 308 0.2 0.19 to 0,21, 0, 192 to 0.208 ot 0.090 to 0. 11, 0,092 to 0. 108, 3.0 2.97 to 3.03 0,942 to 0.957 10.0 9,90 to 10. 10 0.992 to 1.008, 30.0 28.7 to 30.3 0,942 to 0.957 300.0 98.0 to 101.0 0,992 to 1.008, 300.0 207.0 to 303.0 0,042 to 0, 957 Section V ‘Mode! 34004, voLTwereR eaLisharor bpssooa E q fpseaon °O IAN Oo 7 °° o-| L op, = 8 8 ce oe . _ Figure 6-1, Accuracy, Linearity, and DC Output Teat Setup 5-9, FREQUENCY RESPONSE CHECK. ‘Table 5-2. Frequency Response Check NOTE FREQUENCY METER READING Connect 508 feedthru termination ‘Ye 900 kHz 0.99 to 1.01 b, Set Model 3400A RANGE switch and Test 2.2 MHz 0.97 to 1.03 ‘Oscillator output attenuator to 1 volt position. 2.0 MBs 0, 07 to 1.08 fe. Adjust test oscillator output frequency to 58 values listed under "frequency" in Table 5-3; adjust oscillator output voltage to maintain reference level set in step d. If Set S400A to 1 volt range and Test Oscillator Model 3400A does not indicate within values en a0 a under "meter reading” In Table 5-3, perform high frequency calibration procedures, Para €. Adjust Test Oscillator output for 1 volt in- graph 5-25. dication on Model 34004. ‘hps4o0a TEST oscILATOR aus vouTMeTeR posta Figure 5-2, Frequency Respine Fea Seip @ v2 Model 34004, Section V TEST sciLaToR speszn AC?) ° e-0 ea soa rega-oms hpsaooa ws VOLTWETER 5-12, 5-13, b Figure 5-8, Input Impedanc ‘Connect Model 3400A to position B in Figure 5-3. The 3400A meter reading should change Jess than 0.02 volts (2 minor divisions). ‘This corresponds to an input impedance of 10 megohms. CAPACITANCE CHECK, Connect Test Oscillator, $0 ohm feedthru land Model 3400A to position B in Figure 5-3. Insert the resistor lead directly intothe BNC connector on the 400A as an adapter adds ‘capacitances to the measurement, Set S400A to 0,001 volt range and Test Oscil- lator to 400 Hi, Adjust Test Oscillator output for full scale indication on Model $4004. Switch the Test Oscillator Switeh to Expand mode and set a convenient reference level. Change Test Oscillator frequency to 16 kHz, maintaining the reference level set in step ¢- ‘The Model 400A reading should be greater than 0.707 volts. This corresponds to an input Shunt capacity of less than 50 pF. Sot Model 3400A Range switch to 1 V position land repeat step c. ‘Change Test Oscillator frequency to 40 kHz, ‘maintaining the reference level set in step ¢. ‘The Model 3400A reading should be greater than 0.707 volts. This corresponds to an ‘nput shunt capacity of less than 20 pF. (CREST FACTOR CHECK. 2 Test Setup ¢. Adjust Pulse Generator for pulse output with the following characteristics: Pulse Rate - 990 pps as indicated on electronic counter Pulse Width - 10 sec as indicated on ‘electronic counter in time Internal mode. Pulse Amplitude - 7.07 volts as indicated ‘on Model 410¢. NOTE The 410C responds tothe positive peake above the average ofthe input wavetorm. Since the Model 410C is calibrated 0 read the rms value of a sine wave a Correction factor is required to measure pulse amplitude, The correction factor Under these conditions i: 5, mp Equoc = 7a ve ( 7) see waveform below Ea1oc Egioc = Eps€ppl-0) Connect test setup as illustrated in Figure 5-4, Set Model 340A Range switch to 1 volt position, 5-3 Section V ‘Model 34004, PULSE GENERATOR hpaiaa hp34008, ‘VOLTMETER ? 7] eustccrweren —“hpaioe eee ee aX ELECTRONIC COUNTER °8 8 OB eS Apse33u 33 ; A : @ ¢ 20 3 siete | o3) oo [3.3 —1°.2 on“ pit-dore Q oben B Figure 5-4, Crest Factor Test Setup ‘This corresponds to a crest factor of 10 where: Erms = JD (rb) where D ==" Epp VD (-D) Doar Epp (1-D) Epp DD) Tb D 4, ‘The Model 34004 should indicate 1 volt, +4% (includes the 43% accuracy of 410C). e, Adjust pulse generator pulse rate to 250 pps as indicated on electronic counter. ‘This corresponds to a crest factor of 20. ‘Model 34008 should indicate 0.5 volt, 14% (includes the 43% accuracy of 410C.) 5-14, OUTPUT NOISE CHECK. a. Connect 50 ohm feedthru to 8400A INPUT. 5-4 Connect another RMS Voltmeter to DC output, Set -hp- Model S400A to 0,001 volt range. 4. ‘The reading on the RMS Voltmeter should not exceed I mV. 5-15. ADJUSTMENT AND CALIBRATION PROCEDURES. 5-16. ‘The following is a complete adjustment and calibration procedure for the Model 340A. ‘These procedures shouldbe conducted only if thas previously been established by Performance Checks, Paragraph 5-5 to 5-14, that the Model 8400A is out of adjustment. Indiseriminate adjustment of the internal controls to refine settings may actually cause more difficulty. If the procedures outlined do not rectify any maladjust- mente that may exist, and youhave carefully rechecked ‘your connections and settings,refer to Paragraph 5-29, Troubleshooting Procedures for possible cause and recommended corrective action. 5-17, MECHANICAL METER ZERO, 5-18, ‘The mechanical meter zero screw is located on the instrument front panel. If the meter pointer does not indicate zero when the instrument power has been off for at least one minute, mechanically zero the meter following the procedure outlined below. ‘Turn instrument power off; disconnect input signal and any cable connected to J2 (DC OUT) at rear of instrament and allow one minute for meter pointer to stabilize. Rotate zero adjust CW until pointer is to left of zero, moving up scale. Continue until pointer is at zero, If pointer overshoots zero, repeat operation, ‘Model 34004, When the pointer is exactly at zero, rotate the adjusting screw slightly counterclockwise to remove tension on pointer suspension. If the meter pointer moves to the left during this adjustment, repeat steps b and c. 5-19, POWER SUPPLY CHECKS, 5-20. Power supply voltage and ac ripple tolerances are listed in Table 5-4, Test points are also indi- cated in this table. When making ripple voltage measurements, it may be desirable to use a bat- tery powered A.C. Voltmeter (H-P 403B) to avoid any undesirable ground loop currents. 5-21, LOW FREQUENCY CALIBRATION. 5-22, AMPLIFIER GAIN ADJUSTMENT. . Connect test setup illustrated in Figure 8-1, 1. Set Model 3400A RANGE switch to 0,01 volt position. Adjust Voltmeter Calibrator for 0.01 volt rms, 400 Hz output; set DC Voltmeter to read 1.0. Remove Model 3400A top cover; adjust R¢ (CAL) for 1.0 volt as indicated on DC Volt- meter. If RA (CAL) does not have enough rrange to calibrate the de output, the value of RB should be changed. The range of R3 is from 820 ohms to 2. 16 k ohms. Adjust R6 (FULL-SCALE ADJUST) for Model 3400A full-scale meter indication, 5-23, Section V 1/10 SCALE ADJUSTMENT, Connect test setup illustrated in Figure 5-1; ‘omit the DC Voltmeter. Set Model 3400A RANGE switch to 0.1 volt position and adjust Voltmeter Calibrator for 0.01 volt rms, 400 Hz output NOTE ‘The 1/10 SCALE ADJUST should be set slightly low (needle's width) to reduce meter (needle) otfset ‘with shorted input, ©. Adjust RY (1/10 SCALE ADJUST) for Mode! 8400A 1/10 scale meter indication. Change value of RB if it is necessary to increase the adjustment range of RT. ‘The range of RB is, from approximately 270 ohms to 430 ohms. ‘See Table 5-7 5-24, 1 VOLT ADJUSTMENT. 8. Connect test sotup illustrated in Figure 5-1; omit the DC Voltmeter. D. Set Model 8400A RANGE switch to 1 volt position. €. Adjust voltmeter calibrator for 1.0 volt rms, 400 Hz output, 4, Remove right side cover (INPUT side) and adjust R104 (1 V ADJUST) for Model 34004, full-scale meter indication, Table 5-4, Power Supply Checks ‘TEST EQUIPMENT REGULATION RIPPLE POWER AND De vourAacE _ | (vary Line Voltage Between | SPECIFICATIONS SUPPLY CHECK POINT. SPECIFICATIONS |" "103.5 and 126.5 vac) -17.5 Vae | Connect DC Voltmeter, | -16,8 to 18.2 vac | 0.5 volt from nominal | 400 nV rms or AC Voltmeter, or Os- reading at 115 Vac line, | 1.1 mV p-p eilloscope between violet lead on video amplifier (A4) board and chassis ground, +15 vde | Connect DC Voltmeter, | 70.00 78.0 Vae | 1 volt from nominal 400 nV rms oF AC Voltmeter, or Oseil- reading at 115 Vac line. | 1.1 mV p-p Toscope between red/wht/| Due on video amplifier ‘Ad and chassis ground. }-6.3 vde | Connect DC Voltmeter, | -5.9t0-8.5 Vac | 40.1 volt from nominal | 750 zV rms or AC Voltmeter, or Oscil- reading at 115 Vac line. | 2.0 mV p-p loscope between Q3 emitter (grey lead) and chassis ground, 5-5 Section V 5-25, HIGH FREQUENCY CALIBRATION. 5-26. AMPLIFIER GAIN ADJUSTMENT. NOTE: The Test Oscillator used in this procedure should be calibrated af the end of its output cable Connect test setup Illustrated in Figure 5-2. b. Set Model 3400A RANGE switch and Test Oseitlator output attenvator 00. 001V position. fe. Adjust Test Oscillator output trequency for 400 Hz; output voltage for 90% of full scale {as indicated on Model 8400A meter. Switch the Test Oscillator monitor switch to fexpand mode and set a convenient reference level. Change Test Oscillator frequency to 10 MHz, Adjust Test Oscillator output voltage tomain~ tain reference level set in step d. f, Adjust C405 (10 MHz ADJUST) on Ad board for 90% full geale as indicated on the Model ‘SH00A meter, Replace right side cover; readjust C405 sf meter reading varies after replacing the cover. Vary oscillator between Sand 10 MHz; main~ taining reference level set in step d. If the Model 3400A meter reading varies below 85% or above 95% of full scale, repeat step f ‘until optimum response is obtained between 3 and 10 MHz. 5-27, INPUT ATTENUATOR ADJUSTMENT. NOTE ‘The Test Oscillator used in this procedure should be calibrated at the end of its output cable, a. Connect test setup illustrated in Figure 8- b. Set Model 3400 RANGE switch and Test Oécillator output attenuator to 1 volt position. € Adjust Test Oscillator output frequency fr 400 Hz, output voltage for 90° full scale as indi~ ‘cated on Model 34008 meter. Switch the ‘Test Oscillator monitor switch to ‘expand mode and set a convenient reference level. €. Change Test Oscillator frequency to 100 Kitz; adjust Test Oscillator output voltagetomain- tain reference level set in step d. {. Remove Model 34004 bottom cover. Adjust 102 (1, 100 KC ADS) for 90% full sealo as indicated on Model 3400A meter. 5-6 ‘Model 34004, g. Vary oscillator between 100 kitz and 10 MHz; maintain test oscillator output voltage to reference level set in step 4. If Model 34008 meter reading varies more than «1% to 1 Miz, 12% from 1 Mile to 2 MHz, 13% from 2 Mz to 3 MHz, or 8% from 3 Milz to 10 MHz, re- adjust C102 until optimum response is obtain- ed. 5-28, SECOND ATTENUATOR ADJUSTMENT. NOTE ‘The Test Oscillator used in this procedure should be calibrated at the end of its output cable, ‘a, Connect test setup illustrated in Figure 5-2. b. Set Model 400A RANGE switch and Test Oscillator output attenuator to a 0.3 volt position, fe. Adjust Test Oscillator output frequency for 400 Ha; output voltage for 90% full scale as ‘indicated on Model 3400A meter. Switch the Test Oscillator monitor switch to expand mode and set a convenient reference level. e. Change Test Oscillator output frequency to 5 MH; adjust output voltage to maintain re- ference level set in step d. Adjust €503 (10 MC . $V ADJ) for 90% full scale as indicated on Model S400 meter. Vary Test Oscillator hetween 3 MHz. and 10 MHz; maintain test oscillator output voltage to reference level set in step d. If Model 3400A meter reading varies below 85% or above 95% of full scale, repeat steps e and f ‘until optimum response is obtained between ‘Sand 10 Milz. 5-29, TROUBLESHOOTING PROCEDURES. 5-80. ‘This section contains procedures designed to assist in the isolation of malfunctions. ‘These opera- tions should be undertaken only after it has been es~ tablished that the difficulty cannot be eliminated by the Adjustment and Calibration Procedures, Para- graph 5-15. An investigation should also be made to ensure that the trouble is not a result of conditions external to the Model 34008, 5-31. Conduct a visual check of the Model 3400A for possible burned or loose components, loose connec= tions, or any other condition which might suggest a source of trouble, 5-82, Table 5-5 contains a summary of known pro- bleme by front panel symptoms. 5-89, ‘Table 5-6 contains procedures which may be used as a guide in isolating malfunctions. The checks outlined in Table 5-8 are not designed to measure all Modet 34008 circuit parameters, rather only to localize the mal- function. ‘Therefore, it 1s quite possible that add- itional measurements will be requiredto completely isolate the problem. Amplifier gain and biasing ‘may vary slightly from instrament to instrument: therefore, it should not be necessary to precisely duplicate waveforms or values described, NOTE Do not use an extender board on the Chopper Amplifier Board (A6). 5-34, CHECKING THERMOCOUPLES TC401 AND SHECKING THERMOCOUPLES TC401 AND, 5-35, Thefollowing procedure will allowyoutacheck the thermocouples for proper operation in the -hp- Model 3400 RMS Voltmeter. NOTE ‘This check will not yield any informa- tion concerning thermocouple operation for either sluggish or overshoot -under- shoot response on 340A meter, If 2 S400A has the above symptoms re- place thermocouples. 5-36. To perform these checks, supply 5 mA of cur- rent to the heaters of the thermocouples. The -bp- Model 412A DC Vacuum Tube Voltmeter in ohms function on X100 range is ideal for this application. Instruments required for these checks areas follows: One -hp- Model 412A DC Vacuum Tube Voltmeter. Table 5-5. Section V One DC Voltmeter with 10 mV F.s capability such as another -hp- 412A or 3440A/3443A Digital Voltmeter. If the thermocouples fail any of the following checks replace the thermocouples according to procedures ‘outlined in Paragraph 5-37. a, Turnthe instrument off and remove the AG board, NOTE ‘See Figure 6-3 for component locations, b. Connect test leads of 412A, in ohms function fon X100 range, between ground and junction of C418 and C415 on Ad board (this. step checks the resistance of heater in C40). 412A should indicate between 76.5 to 103. 5 ohms. If not within limits, replace the matched set of thermocouples (-hp- Part No. (0855-0003) Leave the 412A connected as in Step b (412A. is used to supply 5 mA of current to heater ‘of TC401 in this step). Connect a DC Volt- meter as follows: Negative lead to pin 11 on AS socket. Positive load to pin 13 on AB socket Voltmeter should indicate between 16.5 mV and+8mV. Note the indicationfor future re- ference. Ifwithinthe test limits, leave DC Volt meter conectedand proceedto step d page 5-14, Front Panel Symptoms SYMPTOM! 1/2 scale readings on all RANGE. switeh settings and input voltages. POSSIBLE CAUSE Chopper Amplifier (AG), Check C612. 3 to 8% meter offset on all ranges with shorted input. RT (1/10 SCALE ADJ) misadjusted. C405 (10 Miz ADJ) misadjusted. 400 He calibration low and frequency response falls off above 50 kif 401 or Q402 shorted Switching transients exceed 5% of full scale with shorted input, Check collector voltage of Q201 (should not ex- ceed 9.0 V), Instrument has been overloaded. Check Q201, Q401, Q402 and TC401. See Paragraph §-24 for details on TC401, Meter jitter exceeds 0.5% of full scale. ‘Check Q801, Photochopper Assembly (neons) see Figure 5-9, Verify the value of R606 to be 3.3 k0 (-hp- Part No, 0683-3925), Full-scale difference from range to range. Check resistors in second attenuator. Meter pegs full scale. Check thermocouples, details. See Paragraph 5-34 for ‘Overshoot, undershoot or sluggish response on meter. Replace Thermocouples. See Paragraph 5-97 5-1 section V { PASSES FAILS ‘Model 34004, 5 @- g 3 = @ q \_@ Figure 5-5. Troubleshooting Tree seek cuddle Modet 84004 Section V ‘Table 5-6. ‘Troubleshooting Procedure cack PROCEDURE ACTION ‘Aly a1 wot 40 Ha sigal and st the 84008 t0 | PASSES: Proceea to @ evo range, Measure ac sigmiat junction, | FAILS” Proceed to, Ot ctls and Cui. "he reading shoul be tetween | (trouble proceeding the Ho mi and 280 VRS Chopper Amplifier wore: Do not use an extender board for measurements on Chopper Amplifier board A6. Measure ae signal at junction of CEOS and PASSES: Proceed to @) _ Demodulator Vo08 and VSO, Refer to Figure FAILS: Proceed to @ 5-0 for waveform. {trouble inthe Chopper ‘amplifier. POSITIVE SIDE OF C505 Full Seale deflection Sweep = 5ms/em Vertical = 0,5 V/em DC coupled use 10:1 probe Input to Demodulator Table 5-6. ‘Troubleshooting Procedure (Cont'd) CHECK PROCEDURE ACTION ® Investigate meter (Ml), RS, and RS for opens. ® Remove the input to 400A, _Unsolder red lend Proceed to from pin 19 (A6) and Insort a v10 mV de signal FAILS: Proceed from 73BBR through a 4990 resistor (-hp- Part No. 0757-0327) to pin 19. Measure ac signal at positive side of C605, Refer to Figure 5-7 for waveform, 5-9 Section V Model 34008, POSITIVE SIDE OF 0805 Insert +10 mV signal through 499k? resistor to pin 13 on A6 ‘Sweep = 5 ms/em Vertical = 2.0V/erm DC coupled ‘use 10:1 probe Figure 5-7. Input to Demodulator (feedback loop oper) ‘Table 5-6. Troubleshooting Procedure (Cont'd) CEC | PROCEDURE ACTION © | Measure the de signal at emitter of Qu08, PASSES: Proceed to © Reading shouldbe approximately -2.98 Vae. FAILS: Proceed to @ | Measure the de signal st pin 9 (AS). Reading PASSES: Proceed to @) Should be approximately “65 Ve. FAILS: Droceed to @ @ Investigate R619, R4, and thermocouples. See Paragraph 5-04 for thermocouple check. Investigate Q606 and associated circuit. @® | Measure the ae signal at base of Q80S. Refer Passes: Proceed to @ to igure 8-8 for waveform. FAILS: Proceedto ~ @ BASE OF Q605 Insert +10 mV signal through 4992. resistor to pin 19 on AS ‘Sweep = 5 ms/em Vertical = 0.2V/em AC coupled use 10:1 probe Figure 5-8. Output of Demodulator (feedback loop open) ‘Mode! 34008, Section V Table 5-6, ‘Troubleshooting Procedure (Cont'd) CHECK PROCEDURE ACTION Investigate QG08, CROOA, and ROIS. ® Investigate demodulator V503 and V504. See Paragraph 5-39 for photochopper check. Check chopper neon voltage. Refer to Figure 5-9 for waveform, Current variation through neons may cause meter jitter. For proper chopper action, neon firing potential (most negative point on wave~ form) is normally between §0V and 60V. If the waveform displays noise (nonlinearity) at both extremities, jitter will occur on the meter. If the waveform displays a noise replace the neon subassembly as outlined in Paragraph PIN SOR 5 ON AB Sweep = 2ms/em vertical = 20V/em DC coupled use 10:1 probe Figure 5-9. Neon Drive Voltage ‘Table 5-6, ‘Troubleshocting Procedure (Cont'd) CHECK PROCEDURE AcTION Measure the ac signal at collector of Q602, Refer | PASSES: Proceeato @ to Figure 5:10 for wavelorn. FAILS Proceed 0 Section V ‘Model 34008, COLLECTOR OF Q00? Insert + 10 mV signal through 49910 resistor topin 13 on AS Sweep Vertical = 0.5V/em DC coupled use 10:1 probe 5 ms/em Figure 5-10, Collector of Q602 (feedback loop open) ‘Table 5-6. Troubleshooting Procedure (Cont’é) CHECK 18 PROCEDURE “ACTION ‘Measure the ac signal at base of Q604. to Figure 8-11 for waveform. Refer PASSES Proceed fo Pa* presets © @ BASE OF Q604 Insert + 10 mV signal through 4990 resistor to pin13onA6 Sweep = 5 ms/em Vertical = 5V/em AC coupled no probe required Figure 5-11, Base of Q604 (feedback loop open} ‘Model 34004, Table 5-6, ‘Troubleshooting Procedure (Cont'd) Section V CHECK PROCEDURE Investigate Q604, C605, (and demodulator), V503 and V504. See Paragraph 5-39 for photochopper check. Check chopper neon voltage. Refer to Figure 5-9 for waveform. See check number for details. Investigate Q603 and associated circuit. Increase the level of the inserted signal to 40.2 PASSES: Ve. Measure the ac signal at the base of Q601. FAILS: Refer to Figure 5-12 for waveform, ACTION ceed to ae sweep BASE OF Qeo1 +.2Vsignal through 4999 resistor to pin 13 on AS Vertical = 5 mV/em AC coupled ro probe required 5 ms/em Figure 5-12, Base of Q601 (feedback loop open) Table 5-6, Troubleshooting Procedure (Cont'd) PROCEDURE, Investigate Q601 and associated circuit. Investigate VS01, 802, C601, C602 and R6O1. See Paragraph 5-39 for photochopper check. Check chopper neon voltage. Refer to Figure 5-9 for waveform, See check number (I) for details, Measure the ac signal at the output of impedance PASSES: Proceedto @ converter A2 (negative side of C205). ‘The reading | FAILS: should be approximately 0.96 mV rms. Measure the ac signal at the input to video amplifier ‘Ad positive aide of C402, ‘The reading should be approximately 0.96 mV rms. ‘Measure the ac signal at the base of Qé04. ‘The reading should be approximately 155 mV rms. ACTION Proceed to @ Proceed to Freeetis @ gp nrecsess B gp Proceed to Section V ‘Model 34004, Table 5-6, Troubleshooting Procedure (Cont'd) CHECK PROCEDURE ACTION Measure the ac signal atthe negative side of PASSES: Proceed to @ C427. The reading should be approximately 32 mV rms. Investigate C418 and C415. Investigate Q404, Q405, and Q406 circuit, Also check thermocouples. See Paragraph 5-54 for thermocouple check. ©® Measure the ac signal at emitter of Q402. should be 1.85 mV rms. Reading Investigate Q¢01 and Q402 eireult. Investigate Q403 circuit, Investigate second attenuator circuit A3, @OO®8 ® Measure the ac signal at the input to the impedance converter pin Ton A2 board. ‘Tho reading should bbe approximately 1 mV rms. © Investigate the impedance converter or power supply. See Table 5-4 for specifications on power supply. ® Investigate the input attenuator Al. FAILS: PASSES: FAILS: PASSES: FAILS Proeed ts @ Proceed to Froceetio @ o> Proceed to Proceed to Remove leads of 412A, connected in stepb, 5. land connect 412A between sliver-coloredlead 8. Shouldathermocouple be defective, it is neces- fon R4 (CAL pot on chassis) and pin 14 on AG socket (this step checks the resistance of sary to replace both as a matched pair (see Section ‘VIL, Table of Replaceable Parts) for part number. To replace thermocouples, perform the following steps: heater in TC402, 412A should indicate be- tween 78.5 to 103.5 ohms. a. Leave 412A connected as in step d (412A is used to supply 5 mA of current to heater of b. ‘TC402 in this stop). Note indication on DC Voltmeter connected between pins 11 and 13 ‘on AG socket. Indication should be negative with respect to reading in step ¢ and within I mV of that reading. £. Remove the DC Voltmeter and 412A from S400A. Connect the 412A between pins 11 and 14 on A6 socket (this steps checks for a thermocouples shorted to ground through cover. Indication of 412A should be greater than 200 kf. Ifless than 200 kA, look for short to ground, 5-31. THERMOCOI EXERCISE EXTREME CARE WHEN REMOVING OR REPLACING THE 1 AMPLIFIER PRINTED CIRCUIT BOARD ASSEMBLY AND WHEN SHAP- INGTHE THERMOCOUPLE LEADS. Turn instrument power off and remove right- side (INPUT side) and top covers. Remove the four lead connection to the Ad amplifier board, 1, Black coaxial cable (two Teads) 2. Violet tead 3, White lead/blue lead. Remove the three mounting screws on the amplifier board. Gently pull bottom of board out at the same time relieving stress on thermocouple cable until the board will drop down and the top will clear main frame. Carefully fold board down to expose the four nuts holding the ther= ‘mocouple shield, Remove four shield nuts; lift shield off. Re- move thermocouples, noting orientation, Leads on new thermocouples must be shaped before inserting into PC board. During the shaping process, hold leads between bending point and glass with long-nose pliors. Model 3400 Place the red dots on the thermocouples face down on the Ad Video Amplifier Board. If ‘one of the thermocouples has an additional colored dot place it in the TC402 position. h, Carefully insert new thermocouple leads and solder. 4. Reverse steps e, d, c, b. Note: the violet lead goes to the lower of the two top connec- tors on the Ad board, jk After thermocouple replacements perform a complete adjustment and calibration pro- ‘cedure as outlined in Paragraph 5-15. 5-9, CHECKING PHOTOCHOPPER ASSEMBLY AS. ore. ‘The following procedure should also be performed after replac- Ing a neon subassembly to verify proper position of neons. 5-40. The following procedure verifies proper oper ation of the Photochopper Assembly. If the Photo chopper fails any of the tests below replace the entire Photochopper Assembly (-hp- Part No. 1980-0228) or the neon subassembly (-hp- Part No, 1990-0224) according to procedures outlined in Paragraph 5-41, ‘See Figure 5-9 to check operation of the neons. To ‘cheek the photochopper assembly proceed as follows: a. Remove the Chopper Amplifier board A6, >, Lift the following component leads from the AB board. Negative side of C601 Positive side of C605 Negative side of C606 Base of Q605 c. Place the A6 board on a programmable ex- tender board (-hp- Part No. 5060-6038). Remove pin 13 lead on extender boardclosest to the AS board. 4, Place a1 i:F capacitor (-hp- Part No, 0180- 0260) across the input leads of an ohmmeter (note the polarity af capacitor and chmmeter Teads). @. Connect the chmmeter between pin 13 and ground. {, Turnon the S400A. The ohmmeter should Indicate > 10 k@ (this checks the dynamic series resistance of the modulator). Turn off the 340A, anddisconnect ohmmeter. h. Ground pin 18 on A6 board. Connect ohm- meter between ground and junetion of VS01 and V502. Section V 1, Turn on the S400A, The ohmmeter should Indicate <7 KO (this checks the dynamic parallel resistance of modulator). ‘Turn off the 34008. Disconnect all connec tions made i step h. k. Connect ohmmeter between ground and V503 lead going to base of Q605, 1, Turn on the 3400A. The ohmmeter should indicate > 10 k® (this checks the dynamic series resistance of demodulator), m, Turn off the 8400A. Disconnect ohmmeter. 1, Ground V503 lead going to base of Q605 and connect chmmeter between ground and the junction of V508 and V504. ©. Turnon the 3400. The ohmmeter should indicate < 10 k (this checks the dynamic parallel resistance of demodulator). . Turn off the S400A. Disconnect ohmmeter and reconnect all component leads cisconnec ted in step b. & Replace chopper amplifier board. 5-41, REPLACEMENT OF NEON SUBASSEMBLY PART NO. 5-42, To replace neon subassembly, proceed as follows: Remove chopper amplifier assembly (A6). 'b. Disconnect the photochopper cable at pins 2, 8, 4, and 5 on PC board. €. Remove two phillipshead screws ontopcover of the photochopper block, NorE————— Note the orientation of neon sub- assembly. The neon subassembly does not lie flat but at an angle ‘within the photochopper block. 4. Remove the neon subassembly. NOTE: Clean the neon lamps with a tissue to remove finger prints before inserting new neon sub assembly in photochopper block. fe. With @ new neon subassembly, feed the cable through the hole in the PC board. Place the ew neon subassembly Inte photochopper block in the same orientation as the old neon subassembly. Section V Replace the top cover and two phillips head sserews in photochopper block. g& Reconnect the cable to pins 2, 8, 4 and 5, The larger Dlack lead in the cable connects to pin 2. Other leads identifications are as follows: White lead to pin 3 Green and ved lead to pin 4 ‘Thin black lead to pin 5. h. Replace chopper amplifier board, 5.42. SERVICING ETCHED CIRCUIT BOARDS 44 ‘The -hp- Model 3400A has five etched circuit boards, Use caution when removing them to avoid damaging mounted components. ‘The assembly and “hp- Part No. are silk screened on the interior of the circuit board to Identify it. Refer to Soction VII for 5-45, ‘The etchedeireuitboards are a plated-through type. ‘The electrical connection between sides of the board is made by & layer of metal plated through the component holes, When working on these boards, observe the following general rules: a Use soldering iron core solder. Iow-heat (25 to 50 watts) small-tip nda smal? diameter rosin parts replacement and -hp- part number Information. Model 3400 Circuit components can be removed by plac- ing the Soldering iron on the component lead ‘on esther side of the board and pulling upon lead, Ifa component is obviously damaged, clip Teads as close to component as possible and then remove, Excess heat can causethe tereult and board to separate or cause dam= e to the component, Component lead hole should be cleaned be- fore inserting new lead. ‘To replace components, shape new leads anc ingert them in holes. Rehoat with iron and add solder as requiredto insure a good elec~ trical connection Clean excess flux from the connection and Agjoining area, WATER, COMMERCIAL CLEANERS, OR DETERGENTS WILL CAUSE PER- MANENT DAMAGE TO PROTOCHOPPER ASSEMBLY AS. ‘To avoid surface contamination of the print- ed circuit, clean with woak solution of warm ‘water and mild detergent after repair. Rinse thoroughly with clean water. When complet ely dry, spray lightly with Krylon (#1302 or equivalent). ‘Table 5-7. Factory Selected Components VALUE FUNCTION vow | normaL | mow Adjust low frequency (10 Hz) response. 100 uF (selected) ‘Adjust high frequency (10 MHz) of Second Attenuator | S pF | 12 pF | 15 pF ‘on 0.001 V and 1 V ranges. ‘Adjust high frequency (3 Mllz to 10 MHz) of Second zepr | 39 pF Attenuator on 0.3 V and 800 V ranges. Adjust high frequency (10 ME2) of Second Attenuator | == spr | 120F ‘on 0.01 Vand 10 V ranges. ‘See NOTE on schematic. = | 200uF (selected) 200] 120002 | 2.16K0 + 390 2 (selected) Adjust voltage at collector of Q406 (a0 signal input, | 270 300 1. to 2.8 vee). Model 34004, PERFORMANCE CHECK TEST CARD Hewlett-Packard Model 34004 Tests performed by RMS Voltmeter Dak Serial No. 7 DESCRIPTION CHECK ‘ACCURACY, LINEARITY AND DC OUTPUT: Calibrator 34000 Meter pe ‘Output Reading Output 0.001 0.000990 0.00101 0.892 _ 1, 008 0.003, 0.00297 _0.00303 0.942 0.987 0.01 0.00990 — 0.0101 0.992 1, 008. 0.03 0.0297 0.0303 0,942 0.957 or 0.0990 0.101 0.992 1.008. 0.3 0.207 0.303 0.942 0.957 Lo 0.990 © 1.01 0.992 1.008 09 0.89 0.91 0,802 0. 908 0.8 0.79 oat 0.792 0. 808 0.7 0.69 om 0.692 ____ 0. 708 0.6 0.59 0.61 0.592 0. 608 0. 0.49 si 0.492 0.508 o4 0.39 oa 0. 392 0. 408 0.3 0.29 ost 0.292 0.308 0.2 0.19 0.21 0.192 0.208 0.1 0.090 9.11 0.092 0, 108 3.0 2.97 3.03 0.942 0.957 10.0 9.90 10.10 0.992 1,008. 30.0 29,7 90.8 0,042 0.957 100.0 99.0 101.0 0.992 1,008, 300.0 297.0 303.0 0.942 __ 0.987 FREQUENCY RESPONSE CHECK: F Meter 'requency Resting 18 He 0.95 ___ 1.05 45 He 0.95 1105 100 He 0.99 1101 900 KH 0.99 101 1,2 MHz 0.98 1.02 1.8 Mz 0.98 1102 212 Miz 0.97 —— 1103 2.8 Mz 0.97 1103 3.2 MBz 0.95 1.05 9.8 Mi 0.95 1.08 INPUT IMPEDANCE CHECK; Resistance 30 MQ or greater Capacitance 50 pF or less 0.001 V to 0.3 V] 20 pF or less 1 V to 300 V (CREST FACTOR CHECK: 10:1 full seale 20:1 half seale OUTPUT NOISE CHECK: 1 mV RMS or less Model 34004 Section VI SECTION VI CIRCUIT DIAGRAMS 6-1, INTRODUCTION. 6-2. This section contains the circuit diagrams necessary for the operation and maintenance of the Modet 34004 RMS Voltmeter. Included are schematic and parts location diagrams. 6-3. SCHEMATIC DIAGRAMS. 6-4. ‘The schematic diagrams depict the etrcuits conlained within each assembly of the 3400A as well as assembly interconnection, Main signal paths and significant feedback paths are identified, 6-5, The schematic diagrams are arranged in ascending order of assembly reference designation 6-6. PARTS LOCATION DIAGRAMS. 6-1. The parts location diagrams show the physical location of parts within an assembly. Parts are Identified by reference designation. A parts location diagram is included for each assembly which does not have adequate silk screening of reference designations 6-8, ‘The parts location diagrams are located on the same figure as the achematic of the assembly. ot Section VI Model 34008, GENERAL SCHI MATIC NOTES ——————__ COMPLETE REFERENCE DESIGNATIONS ARE SHOWN. COMPONENT VALUES ARE SHOWN AS FOLLOWS UNLESS OTHER- WISE NOTED. RESISTANCE IN OHMS CAPACITANCE IN MICROFARADS. -£ DENOTES POWER LINE GROUND (VOLTMETER CHASSIS ) GY DENOTES CIRCUIT GROUND; ON PRINTED CIRCUIT ASSEMBLY. DENOTES MAIN SIGNAL PATH, DENOTES DC FEEDBACK PATH. 9 2 rniores ac rreppack PATH, ————— DENOTES SHIELD. 5. (7) penores rRonT PANEL MARKING. [7] DENOTES REAR PANEL MARKING. MJ pexores screwpRiver apsusr. FS SSQQINF DENOTES COMPONENTS NOT MOUNTED ON, ASSEMBLY. % AVERAGE VALUE SHOWN, OPTIMUM VALUE SELECTED AT FACTORY. SEE TABLE 5~ 8, —< (DENOTES SECOND APPEARANCE OF A CONNECTOR PIN. NOTES Rg RIGS e305 Agee 10 TAN FROM 84 K 10 sib To rw FROM aT aot A3 thp Pan wo, 03400-68801) caTHooe FOLLOWER y Al (Ap PART No. 03400-66501) | a S301 {of a. PART NO. 03400-63401) Al Hp PaRT No. 03400-66501) ‘ CATHODE FOLLOWER 2 (hp pant nd 03400-66802) Figure €-1. Input Attenuator Al, Impedance Converter A2, and Second Atteruator AB Sehematie and Parts Locaticn Diagram 63/644 Up any no, 03400-86503) sine eames eas) s 5503) Figure 6-2, Video Amplifier Ad Schematic and Parts Location Diagram | | | { s-t/e-8 (hp Part No. 08400-66508) 66508) Figure 6-3. Photochopper AS, Chopper Amplifier AB, and Thermocouple Pair (Part of Ad) Schematic and Parts Location Diagram 1/6-8 SERIES RES SERIES AE A7 (Ap Part No. 03400-66510) Rev A -PlLed- 9, @BsO ~112¥0- MODEL 3400A RMS VOLTMETER 0-66510) SERIES REE Bown Qos ors r SOTTTTATY series res || a LEY seem pues] ewirren, roULoweR Figure 6-4, Power Supply AT Scherratic and Parts Location Diagram 6-9/6-10 ‘Model 34004, Section VII SECTION VII REPLACEABLE PARTS 7-1. INTRODUCTION. 7-2, This section contains information for ordering replacement parts, ‘Table 7-1 lists parts in alpha~ meric order of their reference designators and indi- cates the description, -hp- part number of each part, together with any applicable notes, and provides the following: ‘a, Total quantity used in the instrument (TQ column). The total quantity of a partis given the first time the part number appears. b, Deseription of the part, (See list of abbrevia- tions below.) cc. ‘Typical manufacturer of the part in a five= digit code, (See Appendix A for list of manu- facturers.) Manufacturer's part number. 1-3, Miscellaneous parts are listed at the end of ‘Table 7-1, 7-4, ORDERING INFORMATION. 1-5. To obtain replacement parts, address order or inquiry to your local Hewlett-Packard Field Office. (See Appendix B for list of office locations.) Identity parts by their Hewlett-Packard part numbers. Include Instrument model and serial numbers. 7-6. NON-LISTED PARTS. 7-1. To obtain a part that is not listed, include: Instrument model number. b. Instrument serial number. cc. Description of the part. 4. Function and location of the part. Br a Q “Ta, photocell, et acs He Se foeecs fe Ep geo Sees Ge pst mA 9) = 1079 pw v sie = ett, Mat See Gi slotsiee Roy ea wr zane as Sp cmmaee e me pith. — ee ce Be 2a 10 vate Pere bh # honey (tes) %, normally agen “ =e TET Beewe euemnns tha lata BD Pvpont de Nereus ort68-4 te Section VI ‘Model 34008 @ @ AS ® > ohh | © INDEX DESCRIPTION Quanrrry os 7 row Pavel 7 os400-00204 2 Meter Trim 1/3 module 1 5020-5368 3 Side Cover 611 sm 2 5000-8565 ‘ rane Assembly 2 so6o-o708 5 ‘Top Cover (with hanae) 1 oscon-sc103 ‘ Rear Panel 1 os4o0-00208 1 Betfom Cover 8x11 sm 1 5000-0571 3 Foot Assembly 1/8 modute 2 soco-o727 ® syacer 1/3 moda 1 020-2982 1 Hinge 2 5040-0709 1" Tit and 1/3 modute 1 1490-0081 12 Figure 7-1 Modular Cabinet Moder 3400, ‘Table 7-1. Replaceable Parts Section VIE rr. | mer. PART NO. REFERENCE P _ DestGxaTor | PART No. 7 Pesce oe ar ‘5400-88501 | Assombiye Tnpat Attenuator Board a 3400-80502 ‘Assembly: Impedance Converter Board a3 3400-83401 Assembly: Second attenuator M 13400-68503 Assembly: Amplifier Board a5 1990-0223 ‘Assembly: Photoconductor Chopper Part ‘LAG, Note: matched neon subassembly (D301 and 8809) available, =hp- Part No. 1990-0224 a6 3400-68508 Assembly: Chopper Amplifier Board " 3400-86510 Assembly: Power Supply Board a o1e0.0152 Cr fxd Al elect 2x40 1 +0% -10% 200 vade 200 vow a 0180-0148 1 | cr taal elect 890 uF -10% +100% 18 vdew 3A, 8 0160-3388 2) cy txd'cer$000 pr 20% ca 160-0379 1 | Ce td mea 4775 pF 210% 500 vdew 5 thru C100 [Not assigned cro 170-0022 1 | cr fxd my 0.1 uF 320% 600 waew cio (0132-0003 1 var poly 0,7 ~ 3.0 pF 103 0150-0058 1 |G: fxd cer 2-2 pi 600 dew C104 thew Not assigned C200 coo 0170-0019 CC fxd my 0.1 F 38% 200 vdew 202 150-0081 1 | Ci maT? 2 pr ss 500 vaew 203 ‘180-0060 2| Ci ted elect 200 uF 10% +100% 8 vaew 204 (3130-0089 3 C: ted elect 10 pF 150 vacw ca08* 0120-0039 4] Gi fed Al elect 100 pF: 75% -10% 12 vdew 208 0140-0201 1 | cz fxd mica 12 pF 18% 300 vaew 207 180-0081 1 | Gr fe elect 100 uF -10% -100% 15 vaew e208, 0150-0003 3 |G: tea cor 0.01 uF 20% «00% 100 vdew 200 thew Not assigned cal cana 0180-0087 (C; fd mica 12 pF 25% 800 vdew G30 0121-0039 1 | ce var -s0 pr 304s 0160-0196 1 | Ce sxe mica 24 pF 25% aos 0160-0987 2 | Cé fxd mica lap +5% 500 vdew 6308 thew Not assigned cant 402 0120-0083 CC fxd elect 600 uF -20% +100% 3 wdew e403 0150-0082 1] Ci fxd eer 0.05 F $20% 400 vaew cos 140-0201 CC fxd mica 12 pF <5 500 vdew 40s, 0130-0018 1 |G: var cer 1.5-7 pF 500 wew C408 0180-0137 1 |G: txeTa elect 100 nF 220 10 vdew coor 0180-0080 i fxd elect 200 uF 10% +100% 8 wéew cao 1e0-0127 2| Ci tedcer L uP 120% 25 vaew 409 Not assigned caro 0140-0225 2| Ce teamica 300 pF 21% 300 vdew cat (0180-0224 2| i ted elect 10 uF 10 vaow ca 180-0039 Cr fxd elect 100 uF 12 vaew cas. 0180-0142 2 | Ci fxd elect 20 1B ~10% 100% 25 vaew cas 0140-0198 1 |G: fed mica 150 pF 5% 800 vdew cus, 180-0142 t Exd elect 20 1 -10% «100% 25 waew aL thew Not assigned cata cao 0150-0008 1 | ce fxd cor 0.05 wF 100 vdew cat 140-0725, C2 x4 mica 300 DF 21 300 vaew can 010.0127 i fxd cer 1 uP 220% 25 vdew se2e0 | 30075 00083 | Type PLA 8988 "72982 ootss | type 27 ‘982 | 535-016-4n ‘72982 | 301000 coso 220¢ seaa9 | 192Pt0452-Prs. ‘16488 | Type GA 2 pF 5% 56200 | soprisa e200 | S0D218a1 56220 | torcor2cc2- Det o4oe2 | pstisciz0r 56209 | 3oDIT2A1 ouaia | TA bd ‘2136 | oba ‘982 | 587-062-U2PO-54R ‘2136 | oba mass | oba se2go | soptz0ai ‘72982 | 847-000-75U0-s03aH o4oe2 | Darisciz0y ‘range | 597-010-COPO-19 e280 | 1soploTx0OIOR2 senso | sop116a1 Be2a0 | scis 4062 | Dsusea0ty 200 ¥ e280 | 20D106c015DA5 se2ee | sopis¢at 50209 | ‘Type 40D 4082 | DMISFI815 200 V 6269 | Type 40D obd suas | TA oba o4oe2 | Daisrs0rs3007 Se2e0 | sca Oba Section Vil Replaceable Patts (Conta) Modet 34004 REFERENCE “ip DESIGNATOR | _ PART NO. cane aaa 160-0128 22s, cazs | 140-0176 cat 0180-0104 6928 thew C000 ceot 0180-0081 a0 180-0032 cc003, ceos | 0150-0084 cans: 0180-0111 ca08 0180-0224 aot (9150-0003 cane 0180-0022 ceo 0180-0039 e810, C611 cor 180-0156 ais 180-0039 64 thew e700. ctor x70-0024 cra (0380-0089 roa o1e0-0166 cra 280-0089 ers: 150-0012 70s, c1o7 | 180-0050 eros thre | 0180-0105, e709 ono 0160-0098 cnt 0100-2192 ona 0180-0282 crzot 1902-0045, Gr202 1901-0025, (CR203 thea CRAOO. rior 1901-0025, cnioa 3904-0040, crsos 1902-0040, crio4, CRAG crane, 1901-0025 cot, 1910-0016 CRIB (cRéo9 thea CRA00 creot 1902-0046 cre02 1910-0016 cRe03, 1901-0028 cRa04 (cR80S thea CRTO0 crtor, 1901-0028 CR702 R703 thea | 1901-0025 CRTOG DESCRIPTION, Cr fd cor 2.2 uF 420% 25 vdew (C: fxd mica 100 pF 32% 300 veew ed elect 200 jF 15 vaew Not aasigned Cr fxd Ta elect 50 uF +20" -15% 10 vow fxd elect 10 iF T's = 10 12 dew CC: fxd cor 0.1 uF 48015 -20'% 50 vaew : fxd elect 2 LF 25 vdew : fxd elect 10 uF 10 rdew (Cr fxd cer 0.01 j2F +80" 20% 100 veew : tnd Ta elect 4.9 F 35 vdew C: fxd elect 100 uF 12 veew Not assigned C: fxd Al elect 880 uF 00% -10% 1 vaew C: fd elect 100 uF 12 véew C: fxd my 0,022 wF 220% 200 vdew Ge: fad elect 10 1 100% -10% 130 vow (C: fed my 0.008 uF 410% 200 vdew : fxd elect 10 uF 100% -10% 180 vdow : fd cer 0.01 uP £20' 1000 vdew CC fxd elect 40 pF 100% -15% 50 vaew (fxd elect 50 F 25 vdew fxd elect 100 1 F 420% 20 vdew C: fxd my 0,082 5% 200 wdew : fd Al elect 35 2 +785 0% 250 vdew Diode: avatarche 182 V 12% 400 mW Diode: $1 100 piv Not assigned Diode: $i 100 piv Diode: $1 Diode: avatanene 14 V 45% 400 mW Not assigned inde: si 100 piv Diode: Ge 60 piv Not assigned Diode: breakdown 7.15 ¥ 410% Diode: Ge 60 piv Diode: 1 100'piv Not assigned Diode: $10,5 amp 400 piv Diode: Si 100 piv —e——reee su2a9 4082 50288 104i 56288 se2e0 56080 50289 sais 5307 sozes 080 56289 sovas 50289 628s 56289 e289 50289 50289 e209 56089 oars sa sass 03877 omnis onaee nm oars oss ores 93932 seis oud DMISFi016 300¥ SoD1T4A1 MTA-80-10 SODIGBGOT? Baz DSM sacat sopr7aa2 snp108c015BA TA ‘be SRONISKS SoDIS4A1 Type $4 SODISHAL reap22902 SOD218A1 192P68902-Prs sop218at m0% ob paasae staat 1s0D107x002082~ bys. 1ezP92352-Prs aez0 70999-144 ante poor Sc 5050 ‘70939-2246 aor GD 150 15210939-199 GD 150 3072 ba sora 14 Model 24008, Table 7-1. Replaceable Parts (Cont'é) Section VIE REFERENCE DESIGNATOR CRIOT ire R710 crit cr cRTIs, CRI, ‘cRT20 cis crms, cRrm7 crne cRn19 pst Fl a R 3 rn B Ma MI a @, Qa Qs tar @200 geo 202 thru ‘9400 aor thee ‘Ga0s 04 tos tos, 407 tru ‘Qc00 aot thew ‘aco 60s 608 Qeo7 tara ‘Q700 701, gr02 @108, Q704 Q108' qs RI 2 RS RE BS RS Ri Rue Ro R10 RIT thru R100 ar PART No. 1901-0158 1901-0025, 1902-3223, 1901-0045, 1902-0086 1901-0028, 1450-0419, 2110-0004 1250-0118, 4251-0208 1251-2857 1251-0208, 41251-0194 1120-0920, 41120-0308, 1950-0098, 1960-0035, 1954-0215 1659-0010, 1954-0008, 1852-0096 -0009 1958 0018 1953-0086 4853-0006, 1954-0215, 1954-0022, 87-3331 oer221 0758-0070, 2100-0805 fe12-0048 2100-0721 2100-0412, 0686-3015, oses-avan 89-2695 Te DESCRIPTION Not assigned Diode; $i 200 piv Diode: i 100 piv Diode: Si breakdown 17.4 ¥ £2% 400 mW Dinde: 4 100 piv Diode: ureakcown 7.15 V 210% 400 mW Diode: $1 400 pie Light: Indicator - Lamp No. A165 Fuse: cartridge 1/4 amp 250 V Connector BNC Sack: tolephone open elreuit Connector’ AC power cord receptacle Connector: PC 22 contact Connector; PC 15 contact Meter: fall seale 3 mA ‘Meter: ab seate uppermost (Option 02) onty TSTR: Ge PNP selected ‘STR: Ge PNP Not assigned Not assigned ‘TSTR: Si PNP TSTR: $1 PNP 2NTOB TSTR: $i PNP TSTR: Si aND 2NTO8 Not assigned ‘TSTR: Si PNP 2N3906 TTSTR: $i NPN 2NS901 TSTR: $1 PNP 2N3638 Not assigned ‘TSTR: PNP TSTR: PNP TetR: NPN ‘TSPR: Si NPN 2N2102 Re fxd comp 39 kO 10% 1/2 W R: fxd comp 2209 10% 1/2 W Re fxd met fm 12000 «8% 1/2 W var ww lin 509 20% 2 W fed wr 90048 1/2 W var ww 209 220% var we lin 2000 420% 2.w fed comp 2000 55 1/2 W BE BE fxd comp 470 k8 10% 1/4 W fed comp 36 ki? 83 1/4 W ol assigned ons osss2 oars 26094 oars oes 721685, ‘75015 ost s2i89 230 95354 98054 “hw. chee oars aces oars parts oars oars bats omnis uae 7203 12040 oan oan 03877 ona ona "75042 ‘T1480 uai9s aso aso ouiat ona ona MFR, PART NO. SRISS8-8 sora ‘s210939-225 15210999-199 ba 599.957- WHITE SAG/CAT. 312.250 ant 2u-Laa2 FAC-301 $51-0922-1500-00 $9126915-1113-00 swans bd 2N2006-5 awase1 2nsess sreaige SPS3611 ‘St 1657 en asa1 prea cet ob Series 117-SPC sat0 obet Series 112-SPL ‘Type 11? obd EB 915 EB ATA ob 3635

You might also like