Professional Documents
Culture Documents
RAC Catalogue2015 Low
RAC Catalogue2015 Low
2015 Catalogue
RAC
Room Air Conditioning
www.hitachi.com
2015 Catalogue
RAC
This is Hitachi page 04
ErP design page 08
Technology page 10
Products
RAC Mono page 15
RAC Multi page 35
Product
comparison page 48
Functions page 50
This is HITACHI!
I am MIRAI!
Hitachi Air Conditioning Products Europe - HAPE Production facility - Barcelona, Spain
In 2012 HITACHI widened their activities by the first design stage of a new product, to
setting up HITACHI Air Conditioning Europe production, to installation and operation
SAS. procedures, guaranteeing products ‘Engi-
HITACHI Air Conditioning Europe encom- neered for tomorrow’.
passes all Air Conditioning operations in HITACHI is committed to supplying prod-
the European market, including sales and ucts of outstanding quality with the highest
production. efficiency levels and the best cost-effective-
ness. Achieving success with such ambi-
Air conditioning according to HITACHI tious goals on a global scale does not only
means more innovative ideas, the most involve committing considerable resources,
recent technological developments and, but also implies a bold bet and huge com-
together with engineering and quality mitment to the future.
control processes, producing systems to
improve life in a home and professional en- Among the most prominent companies
vironment. worldwide, with about 360,000 employees,
In producing its range of innovative prod- HITACHI can build on their expertise and
ucts, HITACHI has a responsible and en- knowledge, in the awareness it has been
vironmentally-friendly approach which im- successfully addressing customers' chang-
bues every activity within the process, from ing needs for more than a century. Our de-
The design process starts in Japan's work- Hitachi Air Conditioning Systems Co., Ltd. - Production facility - Shimizu, Japan
shops and production units and is continu-
ously developed via an exchange with the
other units worldwide.
HITACHI Air Conditioning products are
sought after worldwide, whenever there is
a need for high-efficiency products with the
best price-quality ratio and an extremely
long life. The widest product range, matched
to an adequate set of electronic controls, al-
lows HITACHI to offer solutions for any ap-
plication or technical specification.
In addition to the technical support provid- Hitachi Air Conditioning Products (M) - HAPM Production Facility - Kuala Lumpur, Malaysia
ed by HITACHI Air Conditioning Europe, the
local units contribute with their abilities and
know-how to supporting customers from vironment, consider HITACHI Air Condition-
design to after-sale service in starting up ing Europe as your partner, able to guide
and controlling systems. you in all air conditioning choices and ‘In-
The after-sale service relies on a network spiring the Next ...’
of selected professionals and an extremely
fast support in spare parts.
To meet your air conditioning and heating
needs and to assure air quality in your en-
Europe has revisited the original EcoDesign Directive (Directive The efficiency level (a) refers to seasonal efficiency of the system,
2005/32/CE) and widened its field of application in order to achieve called SCOP (heating) and SEER (conditioning) for the average
European 3 x 20 environmental goals (-20% energy consumption, European climate. This efficiency coefficient is going to replace the
-20% CO2 emissions, +20% renewable energies) by 2020. previous COP and EER values.
The initial scope of EcoDesign was E.u.P. (Energy using Products).
However, the present scope of EcoDesign encompasses all prod- Table of minimum SCOP/SEER values for compliance
ucts that are connected to the use of energy (e.g.: windows, pan-
Energy rating SEER Energy rating
elling) and it has been more correctly named E.r.P. (Energy related
A +++ SEER 8.50 SCOP ≤ 5.10
Products).
A ++ 6.10 ≤ SEER ≥ 8.50 4.60 ≤ SCOP < 5.10
A+ 5.60 ≤ SEER ≥ 6.10 4.00 ≤ SCOP < 4.60
What does EcoDesign mean? A 5.10 ≤ SEER ≥ 5.60 3.40 ≤ SCOP < 4.00
EcoDesign means taking into consideration the environmental as- B 4.60 ≤ SEER ≥ 5.10
pects of every product/service in question. C 4.10 ≤ SEER ≥ 4.60
This approach consists in considering CO2 emissions and energy D 3.60 ≤ SEER ≥ 4.10
consumption throughout the entire life of the product (from design to
end of life, including transport).
3 fundamental aspects in terms of compliance are described in Thermal load of the building (called Pdesign)
Directive 2010/30/UE No.626/2011 of 4 May 2011 and in Directive
2009/125/EC No.206/2012 of 6 March 2012. For these reasons, the SCOP (and SEER) give a more accurate
(a) Definition of the minimum efficiency level in heating and con- estimate of the actual efficiency of a system throughout the entire
ditioning time of utilisation.
(b) Definition of the Sound Power level for internal and external
unit at nominal conditions
(c) Definition of the criteria for communication to the user by
means of the label
A++++
A++++
A++++ A ++++
A+++
A+++
A+++ A+++
A++
I II A++
A++ A++
A+
SEER SCOP A+
A+ A+
A
A
A A A A
B
B B B
B B
C C C
C
D C D C
D
E E D
D D
F F E
E
G E G E
FXY,Z
kW XY,Z kW XY,Z F
XY,Z
SEER X,Y F SCOP X,Y F X,Y X,Y
G
kWh/annum XY kWh/annum XY G
XY XY
G G
ZYdB
ZYdB
H-LINK Adapter:
PSC-6RAD for centralised supervision of Room Air Conditioners
All indoor units can be connected with the H-Link adapter (PSC-6RAD) in a single bus according to a communication
protocol developed by Hitachi. This accessory makes residential units compatible with systems in the commercial, servi-
ce industry and industrial range. The basic functions (On/Off, operation mode, set temperature, etc.) are programmable
via the H-Link central controller.
ON OFF
(SPX-DST1 + SPX-WDST8M)
First connection
The optional distributor SPX-DST1 can be
used together with the remote controller
DISTRIBUTOR
when there is a need to centralise the control
of multiple indoor units using only a single wi- Second connection
The new infra-red remote controller, available for a large number of models in
the residential range, includes a host of functions to suit your lifestyle and assure
the utmost comfort in your home. Its neat and essential design inspired by mini-
mal and elegant aesthetics perfectly matches our air conditioners.
All the information on your air conditioner’s operation and condition are cle
arly laid out on the large LCD display and the pictograms on the function
keys make programming easy.
The new infrared remote controller is equipped with a 7-day timer to suit your utilisation needs.
Up to 6 on/off settings may be programmed for each day of the week, from Monday to Sunday.
Up to 2 programs may be stored on the remote controller, for instance one valid in summer and the other in winter.
The table below provides a programming example.
MON TUE WED THU FRI SAT SUN
04:00 ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C
12:00 Decrease
temperature during
14:00 daytime
16:00
18:00 ON 20°C
ECO MODE
It allows you to keep electricity consumption in check
while always assuring fully efficient operation.
POWERFUL MODE
The system works at maximum power in heating or cooling mode for 20
minutes in order to meet the demand for comfort in the shortest possible
time. When the 20 minutes have elapsed the system automatically returns to
the initial condition.
LEAVE HOME
When leaving home for a long period of time in winter, this function prevents
the rooms from getting too cold (below 10°C). The duration of the LEAVE
HOME function may be set for the desired length of time. When the set pe-
riod has expired, the unit goes back to operating in the previously set mode.
INFO
Three different parameters may be displayed with the INFO button.
1. Room temperature: the thermistor fitted in the remote controller lets you
view the room temperature on the display.
2. Electrical consumption display: the monthly electrical consumption
(current & previous month) may be displayed.
3. Malfunctioning self-diagnosis: in the event of failure,
the LCD remote controller displays the error code for
easier maintenance.
SILENT MODE
With the silent mode the sound level of the indoor unit may be lowered with just
one touch by changing the fan speed.
CLEANING
Thanks to this feature the indoor unit will always keep clean and mould
growth may be prevented after cooling operation by means of the evapora-
tor’s drying action.
SLEEP TIMER
The countdown timer may be set up to 7 hours’ duration. The ability to adjust
temperature (±2°C) and lower fan speed assures comfortable sleep and con-
siderable energy savings.
RAC Mono
INDOOR UNITS example:
RAK 25PSB
What type of What cooling What type of What family of What series
air conditioner? capacity? combination? products? of products?
RAK = wall XW = X,Y kW P = only mono-split S = Premium A = series 1
RAF = floor Q = only multi-split X = Cut Out / Akebono B = series 2
RAI = 4-way cassette R = mono and multi-split P = Performance
RAD = ductable E = Eco Comfort
A wide choice of units is available, suitable for both classical and modern environments,
designed for the maximum comfort in terms of performance and indoor air quality,
guaranteeing the maximum energy saving.
PREMIUM
Wall RAK-PSB
+ ION MIST
+21 +43
-20 -10
(1)
AKEBONO
Wall RAK-RXB
RAK 25~35~50RXB
(1)
PERFORMANCE
Wall RAK-RPB / RAK-PPA
RAK 18~25RPB
PAM DC Inverter
Split Heat Pump
RAK 35~50RPB RAK 60PPA RAK 70PPA
Super silenzioso
only 20dBA noise level at the SUPER LOW speed
for guaranteeing peaceful sleeps.
Outdoor unit Unit of meas. RAC-18WPB RAC-25WPB RAC-35WPB RAC-50WPB RAC-60WPA RAC-70WPA
Nominal cooling capacity (min - max) kW 2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20) 6.10 (0.9-6.5) 7.00 (1.5-8.00)
Nominal heating capacity (min - max) kW 2.50 (0.90 - 3.20) 3.40 (0.90- 4.40) 4.20 (0.90- 5.00) 6.00 (2.2- 7.30) 6.80 (0.9-8.5) 8.00 (1.5-9.2)
Nominal cooling power input (min - max) kW 0.55(0.25 - 1.01) 0.70 (0.25 - 1.29) 1.090 (0.25 - 1.46) 1.560 (0.50 - 2.10) 1.85 (0.155-2.300) 2.17 (0.200-2.820)
Nominal heating power input (min - max) kW 0.58 (0.25 - 0.97) 0.88 (0.25 - 1.25) 1.100 (0.25 - 1.70) 1.660 (0.50 - 2.75) 1.88 (0.120-2.550) 2.2 (0.200-2.970)
EER / COP 3.64/4.31 3.57/3.86 3.21/3.82 3.21/3.61 3.30 /3.62 3.23/3.64
SEER / SCOP average climate 7.0/4.30 7.60/4.40 7.20/4.60 7.20/4.41 6.0/4.0 6.8/4.4
Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz
Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"
Indoor unit Unit of meas. RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB RAK-60PPA RAK-70PPA
Cooling SPL (SL / L / M / H) dB(A) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46 30/33/42/48 30/33/42/47
Heating SPL (SL / L / M / H) dB(A) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46 33/34/42/49 30/33/42/47
Cooling air flow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 353/420/485/680 353/410/540/750 480/540/690/930 510/630/870/1020
Heating air flow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 363 / 480 / 570/ 780 380/500/610/820 480/510/720/1050 510/630/870/1080
Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230 295x1030x207 333x1150x245
Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8"
Filter Standard Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-NTW1 Wasabi / SPX-NTW2
ECO COMFORT
Wall RAK-PEB
RAK 18~25~35~50PEB
+21 +43
-15 -10
(1)
Cooling sound pressure level (SL / L / M / H) dB(A) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 28 / 30 / 40 /46
Heating sound pressure level (SL / L / M / H) dB(A) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 25 /30/ 39 /47
Sound power dB(A) 51 54 57 60
Cooling air flow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 333/400/485/600 333/450/600/700
Heating air flow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 333 / 520 / 550/ 660 433 / 510 / 650/ 770
Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218
Weight kg 7,5 7,5 7,5 8
Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"
Condensate drain diameter (ext) mm 16 16 16 16
Standard RAR-5F1 RAR-5F1 RAR-5F1 RAR-5F1
Remote controller (standard, optional)
Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB
Filter Optional Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22
Standard filter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5
Standard WASHABLE WASHABLE WASHABLE WASHABLE
Pre-filter
Optional Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6
AKEBONO
Floor RAF-RXB
RAF-25-35-50RXB
(1)
PERFORMANCE
Floor RAF-RPA
7-day timer
6 on/off settings for every day of the week
2 storable programs (summer/winter).
+21 +43
-15 -10
(1)
DUCT
Low Static Pressure RAD-RPA
+21 +43
-15 -10
DUCT
Middle Static Pressure RAD-PPA
+21 +43
-15 -10
CASSETTE
4 Way RAI-RPA
Leave Home
the feature lets you set a minimum hold temperature
(10°C) in heating mode for the periods you are
away either on holiday or businness;
up to 99 days may be set.
Ideal for holiday homes!
2-WAY 3-WAY 4-WAY
Info key
room temperature reading, power consumption
display, alarm signal.
Clean function
the evaporator is dried to prevent mould formation.
+21 +43
-15 -10
(1)
RAC Multi
INDOOR UNITS example:
RAK 25RPB
What type of What cooling What type of What family of What series
air conditioner? capacity? combination? products? of products?
RAK = wall XW = X,Y kW P = only mono-split P = Performance B = series 2
RAF = floor Q = only multi-split
RAI = 4-way cassette R = mono and multi-split
RAD = ductable
What type of What cooling What type of What family of How many
combination? capacity? application? products? connections?
RAC = only mono-split XW = X,Y kW W = wall P = all Multi 2,3,..,6 =
RAM = only multi-split F = floor 2,3,..,6 environments
C = 4-way cassette
D = ductable
N = universal
Outdoor Units
PAM DC Inverter
Multisplit RAM 33NP2B RAM 53NP2B RAM 68NP3B RAM 90NP5B RAM 110NP6B
Heat Pump RAM 40NP2B RAM 53NP3B RAM 70NP4B
Unit
Outdoor unit RAM-33NP2B RAM-40NP2B RAM-53NP2B
of meas.
Min / Max number of connectible indoor units 2 2 2
Nominal Cooling Capacity (min - max) kW 3.3 (1.5-3.8) 4.0 (1.5-4.2) 5.3 (1.5-6.6)
Nominal Heating Capacity (min - max) kW 4.0 (1.5-4.6) 5.2 (1.5-5.5) 6.8 (1.5-7.2)
Nominal Cooling Power Input (min - max) kW 0.80 (0.20-1.05) 1.05 (0.20-1.15) 1.55 (0.20-1.66)
Nominal Heating Power Input (min - max) kW 0.92 (0.20-1.50) 1.21 (0.20-1.50) 1.79 (0.20-2.01)
EER / COP 4.13/4.35 3.81/4.30 3.42/3.80
SEER / SCOP average climate 6.30/4.30 7.00/4.33 7.15/4.31
Energy Class (SEER/SCOP) A++/A+ A++/A+ A++/A+
Cooling sound pressure level dB(A) 48 49 50
Heating sound pressure level dB(A) 50 51 51
Sound Power - Indoor/Outdoor dB(A) 47/61 47/62 50/62
Dimensions (H x L x D) mm 570x750x280 570x750x280 750x850x298
Weight kg 38 41 53
Power supply V/Ph/Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz
Piping diameter (Liq / Gas) inch 1/4” x 2 / 3/8” x 2 1/4” x 2 / 3/8” x 2 ( 1/4” x 2 / 3/8” x 2 )
Minimum piping length m 3 3 3
Max piping length / max lift m 20 / 10 35 / 20 35 / 20
Max pre-charge length/Amount of additional
m / g/m 20/- 35/- 35/-
refrigerant
Working range °C -10 ~ 43 -10 ~ 43 -10 ~ 43
(cooling, heating) °C -15 ~ 21 -15 ~ 21 -15 ~ 2
Refrigerant R410A R410A R410A
+21 +43
-15 -10
COMBINATIONS
DUCTABLE MEDIUM
WALL FLOOR CASSETTE
STATIC PRESSURE
OUTDOOR UNIT
RAK-QXB RAK-QPB
RAF-RXB RAD-QPB RAI-QPB
RAK-RXB RAK-RPB
18 25 35 50 15 18 25 35 50 25 35 50 18 25 35 50 25 35 50
RAM-33NP2B x x x x x x x x x
RAM-40NP2B x x x x x x x x x x x x x x
RAM-53NP2B x x x x x x x x x x x x x x x x x x x
RAM-53NP3B x x x x x x x x x x x x x x x x x x x
RAM-68NP3B x x x x x x x x x x x x x x x x x x x
RAM-70NP4B x x x x x x x x x x x x x x x x x x x
RAM-90NP5B x x x x x x x x x x x x x x x x x x x
RAM-110NP6B x x x x x x x x x x x x x x x x x x x
AKEBONO
Wall RAK-RXB / RAK-QXB RAK 18QXB
RAK 25/35/50RXB
(1)
Unit of
Indoor unit RAK-18QXB RAK-25RXB RAK-35RXB RAK-50RXB
meas.
Nominal cooling capacity
kW 1.8 (1.0-2.5) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20)
(min - max)
Nominal heating capacity
kW 2.5 (1.1-3.2) 3.20 (0.90- 4.20) 4.00 (0.90- 4.80) 5.80 (2.2- 7.00)
(min - max)
Cooling sound pressure
dB(A) 20/25/30/36 20/26/32/40 22/29/35/42 25/31/39/47
(SL / L / M / H)
Heating sound pressure
dB(A) 20/26/32/38 20/27/33/40 22/30/35/42 25/31/39/48
(SL / L / M / H)
Sound power dB(A) 49 55 60 60
Cooling air flow rate
m3/h 300/330/430/500 300/330/510/560 320/340/430/580 350/400/580/720
(SL / L / M / H)
Heating air flow rate
m3/h 310/360/480/600 290/370/560/610 310/360/480/630 350/420/620/800
(SL / L / M / H)
Dimensions (H x L x D) mm 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210
VERIFICARE CODICI (LA TABELLA È TRATTA DA LISTINO)
Weight kg 11 11 11 11
Piping diameter (Liq / Gas) inch 1/4” / 3/8” 1/4” / 3/8” 1/4” / 3/8” 1/4” / 1/2”
Condensate drain diameter mm 16 16 16 16
Remote controller Standard RAR-6N1 RAR-6N1 RAR-6N1 RAR-6N1
(standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB
Standard filter Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22
Dimensions standard filter
mm 48x243x5 48x243x5 48x243x5 48x243x5
(H x L x D)
Standard Pre-filter Stainless steel Stainless steel Stainless steel Stainless steel
PERFORMANCE
Wall RAK-RPB / RAK-QPB RAK 15QPB
RAK 18/25/35/50RPB
(1) (2)
Unit
Indoor unit RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB
of meas.
Nominal cooling capacity
kW 1.50 (0.90- 2.00) 2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00) 5.00 (1.90- 5.20)
(min - max)
Nominal heating capacity
kW 2.00 (1.00 - 2.50) 2.50 (0.90 - 3.20) 3.40 (0.90- 4.40) 4.20 (0.90- 5.00) 6.00 (2.2- 7.30)
(min - max)
Cooling sound pressure
dB(A) 20/24/30/34 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46
(SL / L / M / H)
Heating sound pressure
dB(A) 20/24/32/35 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46
(SL / L / M / H)
Sound power dB(A) 47 51 54 57 60
Cooling air flow rate 312 / 350 / 400 312 / 350 / 400 333 / 370 / 430 353 /420 / 485
m3/h 353/410/540/750
(SL / L / M / H) / 420 / 440 / 510 / 680
Heating air flow rate 312 / 350 / 420 312 / 350 / 420 333 / 400 / 500/ 363 / 480 / 570/
m3/h 380/500/610/820
(SL / L / M / H) / 480 / 480 570 780
Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230
Weight kg 7,5 7,5 7,5 10 10
Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"
Condensate drain diameter mm 16 16 16 16 16
Remote controller Standard RAR-6N2 RAR-6N2 RAR-6N2 RAR-6N1 RAR-6N1
(standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB
Wasabi / SPX- Wasabi / SPX- Wasabi / SPX- Wasabi / SPX- Wasabi / SPX-
Standard filter
CFH22 CFH22 CFH22 CFH22 CFH22
Dimensions standard filter
mm 48x243x5 48x243x5 48x243x5 48x243x5 48x243x5
(H x L x D)
Standard Pre-filter WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE
Optional Pre-filter Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF7 Stainl. S./SPX-SPF7
AKEBONO
Wall RAF-RXB RAF 25/35/50RXB
(1)
Unit of
Indoor unit RAF-25RXB RAF-35RXB RAF-50RXB
meas.
Nominal cooling capacity
kW 2.50 (0.90 - 3.10) 3.5(0.9-4.0) 5.0 (0.9-5.2)
(min - max)
Nominal heating capacity
kW 3.40 (0.90- 4.40) 4.5(0.9-5.0) 6.0 (0.9-8.1)
(min - max)
Cooling sound pressure
dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/43
(SL / L / M / H)
Heating sound pressure
dB(A) 20/26 / 31 /38 20/26/31/39 22/29/36/44
(SL / L / M / H)
Sound power dB(A) 55 56 59
Cooling air flow rate
m3/h 270 / 390 / 510 / 630 270/390/510/660 300/450/540/720
(SL / L / M / H)
Heating air flow rate
m3/h 300 / 420 / 540/ 660 300/420/540/690 330/480/570/750
(SL / L / M / H)
Dimensions (H x L x D) mm 590 x 750 x 215 590 x 750 x 215 590 x 750 x 215
Weight kg 15 15 15
Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"
Condensate drain diameter mm 16 16 16
Remote controller Standard RAR-6N4 RAR-6N4 RAR-6N4
(standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB
Standard filter Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15
Dimensions standard filter
mm 48x243x8 48x243x8 48x243x8
(H x L x D)
Standard Pre-filter Stainless steel Stainless steel Stainless steel
DUCT
Middle Static Pressure RAD-QPB
RAD 18/25/35/50QPB
Available only for Multi combination. This new compact unit can be mount either in a duct or in a ductless configuration.
Depending on whether ductless or linear ducting installation is opted for, fan static pressure may be adjusted via a sui-
table selector on the electronic board (max. 69Pa).
For further details on static pressure consult Hitachi technical documentation.
IR remote controller or wired remote control shall be separately purchased.
Unit of
Indoor unit RAD-18QPB RAD-25QPB RAD-35QPB RAD-50QPB
meas.
Nominal cooling capacity
(min - max)
kW 1.8 (0.9~2.5) 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.6)
Nominal heating capacity
(min - max)
kW 2.5 (0.9~3.2) 3.5 (0.9-5.5) 4.8 (0.9-6.6) 6.0 (0.9-7.5)
Cooling sound pressure
(SL / L / M / H)
dB(A) 30/33/37/41 30/33/37/41 30/33/37/41 31/35/39/43
Heating sound pressure
(SL / L / M / H)
dB(A) 30/34/38/42 30/34/38/42 30/34/38/42 32/35/39/43
CASSETTE
4 Way RAI-QPB RAI 25/35/50QPB
(1)
Unit of
Indoor unit RAI-25QPB RAI-35QPB RAI-50QPB
meas.
Nominal cooling capacity
kW 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.2)
(min - max)
Nominal heating capacity
kW 3.5 (0.9-5.0) 4.8 (0.9-6.6) 6.2 (0.9-7.6)
(min - max)
Cooling sound pressure
dB(A) 28/31/34/37 30/34/38/42 32/36/40/44
(SL / L / M / H)
Heating sound pressure
dB(A) 29/32/35/38 30/35/39/43 32/36/40/44
(SL / L / M / H)
Sound power dB(A) 50 58 58
Cooling air flow rate
m3/h 330/360/420/510 390/420/510/650 390/450/510/720
(SL / L / M / H)
Heating air flow rate
m3/h 390/420/480/550 450/480/510/660 450/510/540/720
(SL / L / M / H)
Included condensate drain pump yes yes yes
Max height available
cm 30,4 30,4 30,4
for drain pump
Drain pump pressure lift cm 11,5 11,5 11,5
Dimensions (H x L x D) mm 285x580x580 285x580x580 285x580x580
Weight kg 20 20 20
Panel weight kg 4 4 4
Panel dimensions (H x L x D) mm 32x650x650 32x650x650 32x650x650
Panel code RAI-ECPP RAI-ECPP RAI-ECPP
Panel colour (RAL) RAL 9010 RAL 9010 RAL 9010
Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2"
Condensate drain diameter mm 16 16 16
Remote controller Standard RAR-6N2 RAR-6N2 RAR-6N2
(standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB
Standard filter WASABI / SPX-NTW1 WASABI / SPX-NTW1 WASABI / SPX-NTW1
Standard filter dimensions (H x L x D) mm 35x270x5 35x270x5 35x270x5
Pre-filtro standard WASHABLE WASHABLE WASHABLE
MULTI COMBINATIONS
POSSIBLE COMBINATIONS
- - - - - 1,5+1,5+1,5+1,5
ONE UNIT
- - - - - 1,5+1,5+1,5+1,8
- - - - - 1,5+1,5+1,5+2,5
- - - - - 1,5+1,5+1,5+3,5
- - - - - 1,5+1,5+1,5+5,0
1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5+1,8+1,8
1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,5+1,8+2,5
1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+1,5+1,8+3,5
1,8+1,8 1,5+3,5 1,5+3,5 1,5+3,5 1,5+3,5 1,5+1,5+1,8+5,0
1,8+2,5 1,8+1,8 1,5+5,0 1,5+5,0 1,5+5,0 1,5+1,5+2,5+2,5
2,5+2,5 1,8+2,5 1,8+1,8 1,8+1,8 1,8+1,8 1,5+1,5+2,5+3,5
TWO UNITS
POSSIBLE COMBINATIONS
FOUR UNITS
- 1,5+1,5+1,5+2,5 2,5+2,5+3,5+5,0 1,5+1,8+3,5+3,5+5,0
- 1,5+1,5+1,5+3,5 2,5+2,5+5,0+5,0 1,8+1,8+1,8+1,8+1,8
- 1,5+1,5+1,5+5,0 2,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+2,5
1,5+1,5 1,5+1,5+1,8+1,8 2,5+3,5+3,5+5,0 1,8+1,8+1,8+1,8+3,5
1,5+1,8 1,5+1,5+1,8+2,5 3,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+5,0
1,5+2,5 1,5+1,5+1,8+3,5 3,5+3,5+3,5+5,0 1,8+1,8+1,8+2,5+2,5
1,5+3,5 1,5+1,5+1,8+5,0 1,5+1,5+1,5+1,5+1,5 1,8+1,8+1,8+2,5+3,5
1,5+5,0 1,5+1,5+2,5+2,5 1,5+1,5+1,5+1,5+1,8 1,8+1,8+1,8+2,5+5,0
1,8+1,8 1,5+1,5+2,5+3,5 1,5+1,5+1,5+1,5+2,5 1,8+1,8+1,8+3,5+3,5
TWO UNITS
FIVE UNITS
POSSIBLE COMBINATIONS
FIVE UNITS
- 1,5+2,5+2,5+2,5 1,5+1,5+1,8+2,5+2,5 1,5+3,5+1,5+1,8+5,0 3,5+3,5+1,8+2,5+3,5
- 1,5+2,5+2,5+3,5 1,5+1,5+1,8+2,5+3,5 1,5+3,5+1,5+2,5+2,5 3,5+3,5+1,8+3,5+3,5
- 1,5+2,5+2,5+5,0 1,5+1,5+1,8+3,5+3,5 1,5+3,5+1,5+2,5+3,5 2,5+2,5+2,5+2,5+2,5
TWO UNITS (*)
FIVE UNITS
POSSIBLE COMBINATIONS
SIX UNITS
SIX UNITS
SIX UNITS
SIX UNITS
WALL
up-down √ √ √ √ √ √
Auto Swing
right-left √ √ - - √ √
Power consumption display √ √ √ √ √ √
Room Temperature Display Remocon √ √ √ √ √ √
Remocon √ √ √ √ √ √
Operation Lock √ √ √ √ √ √
IU
DSW DSW DSW DSW DSW DSW
One Touch Clean √ √ √ √ √ √
Extended Airflow - - - - - -
Dry contact SPX-WDC3 SPX-WDC3 SPX-WDC1 SPX-WDC3 SPX-WDC3 SPX-WDC1
Auto Restart √ √ √ √ √ √
Auto Changeover √ √ √ √ √ √
√ √ √ √ √ √
ID Switch Software Software Software Software Software Software
(remocon) (remocon) (remocon) (remocon) (remocon) (remocon))
Self diagnosis digital display √ √ √ √ √ √
Cable number between IU and OU 3 + earth 3 + earth 2 + earth 3 + earth 3 + earth 2 + earth
Wasabi Wasabi Wasabi Wasabi Wasabi
standard - SPX-CFH22 SPX-CFH22 SPX-CFH22 SPX-CFH22 SPX-CFH22
Air purifying filter
Wasabi
optional - - - - -
SPX-CFH22
Filter
Micro Mesh
standard Inox Washable Washable Washable Washable
Inox
Pre-filter
Inox Inox
opzionale - - - -
SPX-SPF6 SPX-SPF7
standard remocon parts no. RAR-5W1 RAR-6N1 RAR-5E2 RAR-6N2 RAR-6N1 RAR-5E1
√ √ √ √ √ √
simple wired
(SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB)
RC
optional
weekly timer
wireless
RAK PPA RAK PPA RAK PEB RAF RXB RAF QXA RAF RPA RAD RPA RAD QPB RAD PPA RAI RPA RAI QPB
- - - - - - - - - - -
- - - - - - - - - - -
√ √ √ √ √ √ (√) (√) (√) √ √
√ √ √ √ √ √ (√) (√) (√) √ √
√ √ - √ √ √ (√) (√) (√) √ √
√ √ √ √ √ (√) (√) (√) √ √
√
(1-99) (1-99) (1-99) (1-99) (1-99) (1-99) (1-99) (1-99) (1-99) (1-99)
10 10 10 10-16 10 10 10 10-16 10 10 10-16
√ √ - √ √ √ (√) (√) (√) √ √
√ √ - √ √ √ (√) (√) (√) √ √
- - √ - - - - - - - -
√ √ - √ √ √ (√) (√) (√) √ √
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
√ √ √ √ √ √ - - - √ √
- √ - - - - - - - - -
√ √ - √ √ √ (√) (√) (√) √ √
√ √ - √ √ √ (√) (√) (√) √ √
√ √ - √ √ √ (√) (√) (√) √ √
√ √ √ √ √ √ √ √ √ √ √
DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW
√ √ - √ √ √ (√) (√) (√) √ √
- - - √ √ - - - - - -
SPX-WDC4 SPX-WDC4 SPX-WDC3 SPX-WDC3 SPX-WDC1 SPX-WDC1 SPX-WDC2 SPX-WDC2 SPX-WDC2 SPX-WDC2 SPX-WDC2
√ √ √ √ √ √ √ √ √ √ √
√ √ - √ √ √ (√) (√) (√) √ √
√ √ √ √ √ √ √ √ √ √ √
Software Software DSW (IU) Jumper Software Software Software Software Software Software Software Software
(remocon) (remocon)) Wire (remocon) (remocon) (remocon) (remocon) (remocon) (remocon) (remocon) (remocon) (remocon)
√ √ - √ √ √ (√) (√) (√) √ √
4 + earth 4 + earth 3 + earth 3 + earth 2 + earth 2 + earth 2 + earth 3 + earth 4 + earth 2 + earth 3 + earth
Wasabi Wasabi Nano Titanium Nano Titanium
- Nano Titanium - - - - -
SPX-NTW1 SPX-NTW2 SPX-CFH15 SPX-CFH15
Washable Washable Washable Nano Inox Washable Inox Washable - Washable Washable Washable
√ √ √
(SPX-RCKA) (SPX-RCKA1) (SPX-RCKA)
ECO MODE
It limits the energy consumption for providing always a
high efficiency working (with human activity and position
detection sensor, with human absence sensor, without
sensor).
POWERFUL
The system works at the maximum capacity in heating
and cooling for 20 minutes for quickly satisfying the
comfort request. After the 20 minutes the system is au-
tomatically reset to starting condition.
SILENT MODE
The silent mode offers the possibility of reducing noise
level of the indoor unit by lowering the fan speed.
LEAVE HOME
This function prevents the room temperature from falling
too much (lower than 10°C) when the house is not occu-
pied for long time during winter.
It is possible to set the duration of LEAVE HOME fun-
ction (from 0 to 99 giorni) for the required period.
For some models the minimum temperature can be se-
lected (from 10°C to 16°C).
At the end of the selected period the unit will work ac-
cording to the set temperature previously selected.
TIMER
For all indoor units it is possible to set ON/OFF
by means of a timer integrated in the remocon.
Depending on the model the scheduling can be done on
a weekly base or on 24 h or only on 12h.
SLEEP TIMER
The countdown can be set for up to 7 hours. Tempera-
ture regulation (±2°C) and the reduction of the fan speed
provide comfortable sleeps and a great energy saving.
INFO
Three different parameters can be selected by means
of INFO button.
Room temperature: the thermistor mounted on the re-
mocon allows to visualise on the display the information
of room temperature.
Energy consumption indication : the monthly energy con-
sumption can be displayed (current and previous month) .
Self Diagnosis codes: in case of malfunctioning, the
LCD remocon displays the error code for facilitating the
service operations.
ID SWITCH
When two indoor units are installed very close between
them in the same environment, the IR frequency can be
differentiated on the remocon, for preventing to confuse
individual control signal.
http://erpactive.hitachiaircon.com/it/
Products marked with this symbol comply with the ErP Directive (Energy Related Products) and contribute to reducing the
building's energy consumption.
e-mail: aircon.italy@hitachi-eu.com
The specifications in this catalogue are subject to changes without
www.hitachiaircon.it
prior notice so that HITACHI may offer the latest innovations to its
customers. HITACHI shall not be liable for any errors or omissions
Follow us on contained in this catalogue.