You are on page 1of 1

NOTES:

1. ALL DIMENSIONS ARE IN MILIMETRES & LEVELS IN METRES.

2. THIS DWG SHALL NOT BE SCALED, ONLY WRITTEN DIMENSIONS

TO BE FOLLOWED.

3. USE CONCRETE GRADE M25 (DESIGN MIX) UNLESS SPECIFIED

4. MINIMUM CLEAR COVER TO REINFORCEMENT

FOOTINGS: 50 (TO OUTERMOST BARS), COLUMNS: 40 (TO MAIN BARS)

BEAMS: 25 (TO STIRRUPS), SLABS: 25 (TO OUTERMOST BARS)

(40mm) CLEAR COVER 5. LAP LENGTH SHALL BE AS FOLLOWS


FOR COL
FOR COLUMNS 40d, OTHERS 50d (d IS BAR DIA)

6. THIS DWG SHALL BE READ IN CONJUCTION WITH RELEVANT

SHORTER SPAN ARCHITECTURAL DWG.

40 DIA OF BAR
LAP LENGTH
7. ANY DISCREPANCY SHALL BE DISCUSSED WITH THE
LAPPING TO BE CARRIED OUT IN MIDDLE HALF OF CONSULTANT BEFORE THE WORK IS EXECUTED.
8. MINIMUM DEPTH OF EXCAVATION IS 1200mm FROM NGL

THE COLUMN. COLUMN RINGS (TIES)


9. SBC ASSUMED 250KN/M2

SPACING 100MM 10. STEEL GRADE TO BE Fe500

FOR EXECUTION

LONGER SPAN
MAXIMUM SLOPE 1/6
FLOOR LVL.

REDUCED COLUMN SIZE BARS ALONG


(IF APPLICABLE)

SHORT SPAN

BARS ALONG
LONGER SPAN

PROJECT:
NGL
(AS PER SCH)
SURAJ SINGH
FOOTING TOP RESIDENTIAL BUILDING
EXCEVATION

ARCHITECTS:
AS SHOWN IN
DETAIL DRG
DEPTH

UNIKNOWN ARCHITECTS

CONSULTANT:

VIRAJ KUNKOLIENCAR
B.E. (Civil), AMIE, AIV

D
100MM THK P.C.C.
M10
230MM THK SOILING OVER
COMPACTED SOIL S. K. ASSOCIATES
(IN ABSENCE OF HARD A-11, SIXTH FLOOR, SILVIO HEIGHTS, ST. INEZ,
STRATA)
PANAJI - GOA 403001.
(M): +91-9765848536 (E): viraj@sk-associatesgoa.com

TYPICAL COLUMN/FOOTING ARRANGEMENT SHEET CONTENT: GAD-COLUMNS

CLIENT: SURAJ SINGH

DRAWN: OMKAR CHECKED: VIRAJ

DATE: 14.12.2023 SCALE: N.T.S.

DRAWING NO: SKA/51/01 REV NO: R0