Professional Documents
Culture Documents
Checklist Safe
Checklist Safe
REVISION-R0
S.NO DESCRIPTION
SERVICE MODEL CHECKLIST TEMP CHECKLIST
2 Properties
Beam Check
Sizes As Per Plan As Per Plan
Concrete Grade C40 C40
Main Reinf.Grade FE500 FE500
Shear Reinf.Grade FE420 FE420
Effective Cover(Top&Bot) 60 60
Column Check
Sizes As Per Plan As Per Plan
Concrete Grade C40 C40
Wall Check
Sizes As Per Plan As Per Plan
Concrete Grade C40 C40
5 Beam Modifier
Torsion 0.001 0.001
Edge Beam, I value about 2 & 3 axis 1.5 1.5
Internal Beam,I value about 2 & 3 axis 2 2
6 Column Modifier
I value about 2-2 1 1
I value about 3-3 1 1
8 Wall Modifier
F11 1 1
F22 1 1
F12 1 1
M11 1 1
M22 1 1
M12 1 1
9 Column Rigid Zone Include Rigid Zone Not Include Rigid Zone
10 Wall Rigid Zone Include Rigid Zone Not Include Rigid Zone
14 Min.cover Slab
Clear cover top (mm) 30 30
Clear cover bottom (mm) 30 30
Inner slab rebar layer Layer B Layer B
15 Min.cover beams
Clear cover top (mm) 40 40
Clear cover bottom (mm) 40 40
Preferred bar size (flexure) 28 28
Preferred bar size (shear) 12 12
NOTE:
1 Percentage of compression reinf.will change according to deflection(Point no-17).
2 Load Combination
Service Model Temperature Model
Long Term 1.4DL
1.0Immed.-1.0Sustained+1.0Long Term 1.2DL+1.6LL
Incremental 1.2DL+1.2PTEMP+1.6LL
1.0Immed.-1.0Sustained+1.0Long Term-1.0SW Cracked 1.2DL+1.2NTEMP+1.6LL