Project:

TATA Housing
Designed by: PC
Checked by: Sheet __ of __
Date: 9-Jan-24
Part of structure: Job no: Contents Location:
T1-1.5BHK-SL-64 : Slab Stripping Check

Stripping Check calculations for slabs T1-1.5BHK-SL-60, 92 and 179

Self weight = 3.5 kN/ m2


Long Span = 2.9 m
Short span = 1.215 m
Superimposed load = 0 kN/ m2
Live load = 0 kN/ m2
Total Load = 12.33225 kN

Capacity of 140mm slab at stripping stage


Strenth of concrete at stripping stage
Fck = 15 Mpa

Check for slab moments


Design Load = 5.25 kN/m2
αx = 0.0107 αy = 0.0107
Bending moment in short dir = 0.240488 kNm PCI Fig.8.3.1
Bending moment in long dir = 0.574005 kNm

Maximum bending moment = 0.574005


Min. Eff. Depth required 24.82368 mm a= 1
Effective depth = 96 mm SAFE b= -1296
Area of steel required = 13.89428 mm 2
c= 17814
Area of steel provided = 200.96 mm 2
SAFE width 450

Punching shear check


Design load 4.624594 kN
Punching shear stress 0.12545 N/mm2 < 0.968246 N/mm2
Ok
Provide lifting anchor 6000-1,3-0085
Capacity of anchor 13 kN > 4.624594 kN
Project:
TATA Housing
Designed by: PC
Checked by: Sheet __ of __
Date: 9-Jan-24
Part of structure: Job no: Contents Location:
T1-1.5BHK-SL-64 : Slab Stripping Check

Stripping Check calculations for slabs T1-1.5BHK-SL-60, 92 and 179

Self weight = 2.5 kN/ m2


Long Span = 2.65 m
Short span = 2.33 m
Superimposed load = 0 kN/ m2
Live load = 0 kN/ m2
Total Load = 15.43625 kN

Capacity of 100mm slab at stripping stage


Strenth of concrete at stripping stage
Fck = 15 Mpa

Check for slab moments


Design Load = 3.75 kN/m2
αx = 0.0107 αy = 0.0107
Bending moment in short dir = 0.577262 kNm PCI Fig.8.3.1
Bending moment in long dir = 0.656542 kNm

Maximum bending moment = 0.656542


Min. Eff. Depth required 26.5485 mm a= 1
Effective depth = 96 mm SAFE b= -1296
Area of steel required = 15.91729 mm 2
c= 20375
Area of steel provided = 200.96 mm 2
SAFE width 450

Punching shear check


Design load 5.788594 kN
Punching shear stress 0.157026 N/mm2 < 0.968246 N/mm2
Ok
Provide lifting anchor 6000-1,3-0085
Capacity of anchor 13 kN > 5.788594 kN
Project:
TATA Housing
Designed by: PC
Checked by: Sheet __ of __
Date: 9-Jan-24
Part of structure: Job no: Contents Location:
T1-1.5BHK-SL-64 : Slab Stripping Check

Stripping check calculations for slabs T1-1.5BHK-SL-64 to 67, 148 and 167 to 169

Self weight = 3.125 kN/ m2


Long Span = 3.4 m
Short span = 3.1 m
Superimposed load = 0 kN/ m2
Live load = 0 kN/ m2
Total Load = 32.9375 kN

Capacity of 125mm slab at stripping stage


Strenth of concrete at stripping stage
Fck = 15 Mpa

Check for slab moments


Design Load = 4.6875 kN/m2
αx = 0.0107 αy = 0.0107
Bending moment in short dir = 1.638805 kNm PCI Fig.8.3.1
Bending moment in long dir = 1.797399 kNm

Maximum bending moment = 1.797399


Min. Eff. Depth required 43.92693 mm a= 1
Effective depth = 96 mm SAFE b= -1296
Area of steel required = 44.57425 mm 2
c= 55781
Area of steel provided = 200.96 mm 2
SAFE width 450

Punching shear check


Design load 12.35156 kN
Punching shear stress 0.335058 N/mm2 < 0.968246 N/mm2
Ok
Provide lifting anchor 6000-1,3-0085
Capacity of anchor 13 kN > 12.35156 kN