GMKN1022

Active Data Cable


GENERAL INFORMATION
The GMKN1022 Active Data Cable provides a
5-wire RS232 interface (e.g. RxD, TxD, CTS,
RTS, DTR) between a computer and a mobile
radio.

OPERATION
The cable has to be connected to the 20-pin
Accessory Connector on the rear side of the
radio and into the 9-pin connector of a Data
Device (e.g. PC, Laptop, console etc.).

The Active Data Cable shall

! never be connected to a radio


equipped with a GMCE4053
Expansion Head.
Caution
Do not disconnect the cable
in the middle of a procedure.
This may leave the radio
incorrectly configured and
could degrade the radio’s
performance.

2
CABLE CONNECTIVITY
To Radio Accessory Connector
20 pins

EXTERNAL PTT 3
To Computer
GND 8 9 pins (female)
SWB + 13 Radio Interface Box 1 DCD
(RIB) 2 RxD
3 TxD
4 DTR
DTR 15 RS232 5 GND
CTS 17 Level Shifter 6 DSR
RTS 18 7 RTS
TxD 19 8 CTS
RxD 20 9 RI

Note: If the Active Data Cable shall be used in


conjunction with any other accessory using PTT
functionality (EXTERNAL_PTT), the black colored
cable at the accessory connector of the Active Data
Cable must be removed and cut.

CONNECTOR DETAIL
T o th e c o m p u te r
' #

$ 
R a d io In te r fa c e B o x (R IB )
  '


 &  %
T o R a d io A c c e s s o r y
C o n n e c to r

3
DEMOUNTING OF THE CONTACTS
It might be neccessary to change the pin
position in the connector housing. The
following section describes how to remove the
contacts from the connector housing.

REMOVE CONTACTS FROM ACCESSORY


CONNECTOR
To remove the contacts from the connector
push the tool into the front side slot as shown
in the diagram and pull out the contact.

REMOVE CONTACTS FROM RS232 CON-


NECTOR
Push with the tool into the slot and pull out the
contact.

4
ASSEMBLING RS232 INTERFACE CABLE,
ACCESSORY CONNECTOR KIT AND
SPEAKER CABLE
The following pictures show the RS232
Interface Cable GMKN1016 assembled with
the speaker and the Accessory Connector Kit
GMBN1021 with accessory connector. The
front of both connector housings should be
flush with each other.

All cables should be fixed with a strap (see


figure).

SERVICE
The GMKN1022 Active Data Cable is not
repairable. Order a replacement cable as
necessary.
5
© 2002 by Motorola, Inc.

Motorola and the Stylized M Logo are registered


in the U.S. Patent and Trademark Office.

5/02. All Rights Reserved

6866537D35

@6866537D35@