You are on page 1of 57

2-00-00 44-00-00

32-11-08

6/
5/
4/
3/
2/
1/
Notes:
AGF1

B
DG1

DGF
(3ply)
D(5)

9-00-00
B
B

10.75/12
B
AA(10)
20-06-00

6" brick allowance


spacing = 2-0-0 oc
10.75/12

20T-31-End Std
B

10.75/12
B

Elev A1 - Lot 234-1


11-06-00
CGF
B B
AGF2

overhang = 1-0-0 (finished)


AGF2

bottom of fascia = top of plate


B B

dimensions = feet,inch,sixteenths
B
JF(6)
A(6)

11-06-00
B

pitch = 5.75/12 unless noted otherwise


FG1
(3ply)

20T-29 Rev
B B
20-00-00

unit 2 to unit 3
10" step up from

Elev A1 - Lot 234-2


B(4)

8-06-00
AGF3
AGF3
B
B

EA(4)
EG1
(3ply)

8-06-00
EGF
B
B

10.75/12
B
AA(9)
20-00-00

20T-31 Std
32-11-08
10.75/12
B

10.75/12

11-06-00
B

CGF

Elev A1 - Lot 234-3


B
AGF2(2)
121-00-00

B
B
B
JF(6)
A(6)

11-06-00
B

FG1
(3ply)
B B
20-00-00

all lower roof conventionally framed


B(4)

20T-29 End Rev


8-06-00

Elev A1 - Lot 234-4

AGF3
AGF3
B
B

EA(4)
EG1

E
(3ply)

8-06-00
EGF
B
B

10.75/12
B
AA(9)
20-00-00

32-11-08
10.75/12

20T-31 Std
B

10.75/12

11-06-00
B

CGF
B

Elev A1 - Lot 234-5

AGF2

AGF2
B B
B
G(5)

JK(6)

11-06-00
B
10.75/12

KG1

G3
B

(3ply)

G2
20-06-00

20T-30 Cor Rev

G1
A

B
10.75/12

Elev A1 - Lot 234-6


B

JG5
7-10-00

JG6 JG(2)
JGG1
I(2)

A A

IGF
1-08-00
JG2

JG4
JG3
JG1

Hangers
HGF

6-01-08
JUS26 (2)

4-00-00 1-06-00 12-06-00 13-00-00 15-00-00


THDS26 (46)

SHOP DRAWING APPROVAL


THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be THIS LAYOUT IS THE SOLE SOURCE FOR FABRICATION OF TRUSSES AND VOIDS ALL PREVIOUS ARCHITECTURAL OR OTHER
incorporated into the building design at the specification of the building designer. See individual design sheets for each truss TRUSS LAYOUTS. REVIEW AND APPROVAL OF THIS LAYOUT MUST BE RECEIVED BEFORE ANY TRUSSES WILL BE BUILT.
design identified on the placement drawing. The building designer is responsible for temporary and permanent bracing of the VERIFY ALL CONDITIONS TO INSURE AGAINST CHANGES THAT WILL RESULT IN EXTRA CHARGES TO YOU.
roof and floor system and for the overall structure. The design of the truss support structure including headers, beams, walls,
and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing of Wood
Trusses" available from the Truss Plate Institute, 583 D'Onifrio Drive; Madison, WI 53179. APPROVED BY:__________________________________________ DATE:______________________

revision and date


Empire-Calderwood
Apr 25 2023 - added step in foundation
JOB DESCRIPTION:
June 15 2023 - revised truss direction
Block 234
2023-04-13

SALES REP: SCALE: DATE:


Thorold,Ontario Mike Salo N.T.S.
CONVENTIONAL
Phone: (519) 461-1180 JOB PATH: DRAWN BY: WO #: Project #:
FRAMING BY OTHERS.
Fax: (519) 461-0903 R:\manage\2023\09604A 09604A PR23-09536
wor
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A A 12 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:51 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-0a6czFhfCJmfVek6DUvcK?6nAIz2GWODU4yStVz606k
10-8 7-1-11 6-11-2 6-11-3 6-11-3 6-11-2 4-8-3
6x6 Scale = 1:98.0
5.75 12
6

3x4 T2 T2 3x4
3x6 7
5 3x6
2 1-4
0-1 8

1-1
4

2
11-0-0

4x8 4x8
3 W2 W1 W1 W2 W3 9
T32-4
2-0 2x4

1-1
T1
W3

2
W5 W6 10
8x10 W4

2-1-6
12 W7

1-8

2-8

1-8
11-4

W8 W4
B1 B2 B3
2-9
17 16 15 14 13 12
18 11
3x4 3x6 3x6 3x6 4x4 3x4
7x8
10-8 39-6-8
8-4-2 8-1-10 9-0-8 8-1-10 5-10-10
39-6-8

TOTAL WEIGHT = 12 X 164 = 1970 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY 2100F 1.8E SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY 2100F 1.8E SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 8 2x4 DRY 2100F 1.8E SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 10 2x4 DRY No.2 SPF 18 2623 0 2623 0 0 5-8 2-13 BOT CH. LL = 0.0 PSF
18 - 2 2x4 DRY No.2 SPF 11 2520 0 2520 0 0 MECHANICAL DL = 7.4 PSF
11 - 10 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
18 - 16 2x4 DRY No.2 SPF A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 11. MINIMUM
16 - 14 2x4 DRY No.2 SPF BEARING LENGTH AT JOINT 11 = 3-8. SPACING = 24.0 IN. C/C
14 - 11 2x4 DRY No.2 SPF
THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL WEBS 2x3 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
EXCEPT UNFACTORED REACTIONS NBCC 2015
18 - 3 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS DESIGN COMPLIES WITH:
DRY: SEASONED LUMBER. 18 1839 1298 / 0 0/0 0/0 0/0 541 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
11 1769 1239 / 0 0/0 0/0 0/0 530 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 18 - TPIC 2014

PLATES (table is in inches) BRACING (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.11 FT. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
2 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. LIVE LOAD
2 TMBMVW1*+mMT20 8.0 10.0 Edge 2.50
3 TMWW-t MT20 4.0 8.0 1.75 2.00 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(LL)= L/360 (1.32")
4 TS-t MT20 3.0 6.0 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.22")
5 TMWW+t MT20 3.0 4.0 1.75 0.75 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 5-15, 7-13, 7-12. DBS = 20-0-0 . ALLOWABLE DEFL.(TL)= L/360 (1.32")
6 TTWW+p MT20 6.0 6.0 Edge CBF = 142 LBS. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.43")
7 TMWW+t MT20 3.0 4.0 2.00 1.25 2 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 3 LENGTH OF 3-18. DBS = 10-0-0 . CBF = 271
8 TS-t MT20 3.0 6.0 LBS. CSI: TC=0.88/1.00 (7-9:1) , BC=0.76/1.00 (17-18:1) ,
9 TMWW-t MT20 4.0 8.0 2.00 2.25 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 9-11. DBS = 14-0-0 . CBF = 306 WB=0.90/1.00 (9-11:1) , SSI=0.32/1.00 (6-7:3)
10 TMV+p MT20 2.0 4.0 LBS.
11 BMVW1-t MT20 7.0 8.0 Edge DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
12 BMWW+t MT20 3.0 4.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). COMP=1.10 SHEAR=1.10 TENS= 1.10
13 BMWW-t MT20 4.0 4.0 1.50 2.00 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4,
14 BS-t MT20 3.0 6.0 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12. COMPANION LIVE LOAD FACTOR = 1.00
15 BMWW+t MT20 3.0 6.0 2.50 1.50
16 BS-t MT20 3.0 6.0 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN
17 BMWW+t MT20 3.0 4.0 1.50 1.50 THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW TRUSS PLATE MANUFACTURER IS NOT
18 RESPONSIBLE FOR QUALITY CONTROL IN THE
LOADING TRUSS MANUFACTURING PLANT .
Edge - INDICATES REFERENCE CORNER OF PLATE TOTAL LOAD CASES: (8)
TOUCHES EDGE OF CHORD. NAIL VALUES
CHORDS WEBS PLATE GRIP(DRY) SHEAR SECTION
MAX. FACTORED FACTORED MAX. FACTORED (PSI) (PLI) (PLI)
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX MAX MIN MAX MIN MAX MIN
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) MT20 650 371 1747 788 1987 1873
FR-TO FROM TO LENGTH FR-TO
1- 2 0 / 22 -109.0 -109.0 0.04 (1) 10.00 3-17 -510 / 37 0.15 (2) PLATE PLACEMENT TOL. = 0.250 inches
2- 3 0 / 31 -109.0 -109.0 0.45 (2) 10.00 17- 5 0 / 821 0.18 (2)
3- 4 -4018 / 0 -109.0 -109.0 0.55 (1) 3.92 5-15 -1134 / 0 0.46 (2) PLATE ROTATION TOL. = 5.0 Deg.
4- 5 -4018 / 0 -109.0 -109.0 0.55 (1) 3.92 15- 6 0 / 1342 0.30 (2)
5- 6 -3165 / 0 -109.0 -109.0 0.51 (1) 4.30 6-13 0 / 1018 0.23 (3) JSI GRIP= 0.90 (17) (INPUT = 0.90 )
6- 7 -2990 / 0 -109.0 -109.0 0.52 (1) 4.38 13- 7 -811 / 17 0.33 (3) JSI METAL= 0.96 (16) (INPUT = 1.00 )
7- 8 -3017 / 0 -109.0 -109.0 0.88 (1) 3.11 7-12 -282 / 27 0.18 (2)
8- 9 -3017 / 0 -109.0 -109.0 0.88 (1) 3.11 12- 9 0 / 376 0.08 (2)
9-10 0 / 30 -109.0 -109.0 0.44 (3) 10.00 18- 3 -4333 / 0 0.73 (1)
18- 2 -415 / 0 0.0 0.0 0.04 (1) 7.81 9-11 -3493 / 0 0.90 (1)
11-10 -185 / 0 0.0 0.0 0.02 (1) 7.81

18-17 0 / 3766 -18.5 -18.5 0.76 (1) 10.00


17-16 0 / 3167 -18.5 -18.5 0.66 (1) 10.00
16-15 0 / 3167 -18.5 -18.5 0.66 (1) 10.00
15-14 0 / 2314 -18.5 -18.5 0.54 (1) 10.00
14-13 0 / 2314 -18.5 -18.5 0.54 (1) 10.00
13-12 0 / 2879 -18.5 -18.5 0.63 (1) 10.00
12-11 0 / 2637 -18.5 -18.5 0.51 (1) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A AA 28 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:34 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-VyZWR?eC?OEDMv708QgSNcYVrR9e4S49ilJ5sOzRBRJ
10-8 7-1-11 6-11-2 6-11-3 6-11-3 5-0-5
4x6 Scale = 1:93.7
5.75 12
6

4x4 T2 4x6
3x6 T3 7
5

4 2x4
W1

11-0-0
8
4x8
3 W2 W1
W5
T1
W4 W3

5-3-4
W8 W6
2x4

12 W7
11-4

W9
B1 B2 B1
14 13 12 11 10
15 9
4x8 4x4 3x6 3x6 3x6 3x4 4x6
10-8 32-11-8
8-4-2 8-1-10 9-0-8 7-5-4
32-11-8

TOTAL WEIGHT = 28 X 146 = 4096 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 8 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
15 - 2 2x4 DRY No.2 SPF 15 2203 0 2203 0 0 5-8 2-6 BOT CH. LL = 0.0 PSF
9 - 8 2x4 DRY No.2 SPF 9 2101 0 2101 0 0 MECHANICAL DL = 7.4 PSF
15 - 13 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
13 - 11 2x4 DRY No.2 SPF A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 9. MINIMUM BEARING
11 - 9 2x4 DRY No.2 SPF LENGTH AT JOINT 9 = 2-4. SPACING = 24.0 IN. C/C

ALL WEBS 2x3 DRY No.2 SPF THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
EXCEPT SMALL BUILDING REQUIREMENTS OF PART 9,
15 - 3 2x4 DRY No.2 SPF UNFACTORED REACTIONS NBCC 2015
7 - 9 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS DESIGN COMPLIES WITH:
DRY: SEASONED LUMBER. 15 1544 1091 / 0 0/0 0/0 0/0 453 / 0 0/0 - PART 9 OF BCBC 2018 , ABC 2019
9 1474 1033 / 0 0/0 0/0 0/0 442 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 15 - TPIC 2014

PLATES (table is in inches) BRACING (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.12 FT. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
2 TMV+p MT20 2.0 4.0 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. LIVE LOAD
3 TMWW-t MT20 4.0 8.0 2.00 2.25
4 TS-t MT20 3.0 6.0 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(LL)= L/360 (1.10")
5 TMWW-t MT20 4.0 4.0 2.00 1.75 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.16")
6 TTWW+p MT20 4.0 6.0 Edge 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 5-12, 6-10, 7-9. DBS = 20-0-0 . CBF ALLOWABLE DEFL.(TL)= L/360 (1.10")
7 TMWW-t MT20 4.0 6.0 2.00 2.25 = 284 LBS. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.29")
8 TMV+p MT20 2.0 4.0 2 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 3 LENGTH OF 3-15. DBS = 14-0-0 . CBF = 305
9 BMVW1-t MT20 4.0 6.0 1.75 3.00 LBS. CSI: TC=0.87/1.00 (3-5:1) , BC=0.64/1.00 (14-15:1) ,
10 BMWW+t MT20 3.0 4.0 WB=0.85/1.00 (7-9:1) , SSI=0.33/1.00 (6-7:3)
11 BS-t MT20 3.0 6.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE).
12 BMWW+t MT20 3.0 6.0 2.50 1.50 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
13 BS-t MT20 3.0 6.0 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12. COMP=1.10 SHEAR=1.10 TENS= 1.10
14 BMWW-t MT20 4.0 4.0
15 BMVW1-t MT20 4.0 8.0 2.00 2.50 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN COMPANION LIVE LOAD FACTOR = 1.00
THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW
Edge - INDICATES REFERENCE CORNER OF PLATE
TOUCHES EDGE OF CHORD. LOADING TRUSS PLATE MANUFACTURER IS NOT
TOTAL LOAD CASES: (8) RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .
CHORDS WEBS
MAX. FACTORED FACTORED MAX. FACTORED NAIL VALUES
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX PLATE GRIP(DRY) SHEAR SECTION
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) (PSI) (PLI) (PLI)
FR-TO FROM TO LENGTH FR-TO MAX MIN MAX MIN MAX MIN
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 3-14 -543 / 0 0.16 (2) MT20 650 371 1747 788 1987 1873
2- 3 0 / 32 -109.0 -109.0 0.70 (2) 10.00 14- 5 0 / 862 0.19 (2)
3- 4 -3184 / 0 -109.0 -109.0 0.87 (1) 3.12 5-12 -1152 / 0 0.47 (2) PLATE PLACEMENT TOL. = 0.250 inches
4- 5 -3184 / 0 -109.0 -109.0 0.87 (1) 3.12 12- 6 0 / 1358 0.31 (2)
5- 6 -2265 / 0 -109.0 -109.0 0.77 (1) 3.63 6-10 -405 / 171 0.44 (2) PLATE ROTATION TOL. = 5.0 Deg.
6- 7 -1587 / 0 -109.0 -109.0 0.69 (1) 4.30 10- 7 0 / 576 0.13 (2)
7- 8 0 / 45 -109.0 -109.0 0.74 (3) 10.00 15- 3 -3490 / 0 0.59 (1) JSI GRIP= 0.89 (5) (INPUT = 0.90 )
15- 2 -412 / 0 0.0 0.0 0.04 (1) 7.81 7- 9 -2273 / 0 0.85 (1) JSI METAL= 0.73 (13) (INPUT = 1.00 )
9- 8 -167 / 0 0.0 0.0 0.09 (3) 7.81

15-14 0 / 3033 -18.5 -18.5 0.64 (1) 10.00


14-13 0 / 2366 -18.5 -18.5 0.53 (1) 10.00
13-12 0 / 2366 -18.5 -18.5 0.53 (1) 10.00
12-11 0 / 1490 -18.5 -18.5 0.41 (8) 10.00
11-10 0 / 1490 -18.5 -18.5 0.41 (8) 10.00
10- 9 0 / 1275 -18.5 -18.5 0.40 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A AGF1 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:34 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-VyZWR?eC?OEDMv708QgSNcYhXRJB4dU9ilJ5sOzRBRJ
10-8 3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 1-11-8
4x6 Scale: 1/8"=1'
5.75 12
13
12 14
11 15
4x6 T2 4x6
3x6 10 16
W2 W1 W2 T4
9 W3 W3 17
W4 T3 40 T5 W4
8 45 39 38 41 42 43 18
7
19

11-0-0
6 3x8 3x8 3x8 3x8 3x8 3x8 3x8
5

7-0-0
4 T1
ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6
ST5 ST5

5-3-4
3 W5
ST4
ST3
ST2
12 ST1
11-4

W6
B1 B2 B3

37 36 35 34 33 32 31 30 28 27 26 25 24 23 22 21 20
29
4x6
10-8 3x6
32-11-8
3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 1-11-8
32-11-8

TOTAL WEIGHT = 182 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
37 - 2 2x3 DRY No.2 SPF SPECIFIED LOADS:
1 - 8 2x4 DRY No.2 SPF THIS TRUSS DESIGNED FOR CONTINUOUS BEARINGS. TOP CH. LL = 31.3 PSF
8 - 13 2x4 DRY No.2 SPF DL = 6.0 PSF
13 - 19 2x4 DRY No.2 SPF THIS TRUSS REQUIRES RIGID SHEATHING ON EXPOSED FACE. BOT CH. LL = 0.0 PSF
20 - 19 2x3 DRY No.2 SPF DL = 7.4 PSF
37 - 29 2x4 DRY No.2 SPF BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) TOTAL LOAD = 44.7 PSF
29 - 25 2x4 DRY No.2 SPF
25 - 20 2x4 DRY No.2 SPF BRACING SPACING = 24.0 IN. C/C
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
ALL WEBS 2x3 DRY No.2 SPF MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL GABLE WEBS SMALL BUILDING REQUIREMENTS OF PART 9,
2x3 DRY No.2 SPF ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015
DRY: SEASONED LUMBER.
LOADING THIS DESIGN COMPLIES WITH:
GABLE STUDS SPACED AT 2-0-0 OC. TOTAL LOAD CASES: (8) - PART 9 OF BCBC 2018 , ABC 2019
- PART 9 OF OBC 2012 (2019 AMENDMENT)
CHORDS WEBS - CSA 086-14
MAX. FACTORED FACTORED MAX. FACTORED - TPIC 2014
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
PLATES (table is in inches) (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DESIGN ASSUMPTIONS
JT TYPE PLATES W LEN Y X FR-TO FROM TO LENGTH FR-TO -OVERHANG NOT TO BE ALTERED OR CUT OFF.
2 TMV+p MT20 2.0 4.0 37- 2 -285 / 0 0.0 0.0 0.03 (2) 7.81 26-38 -223 / 0 0.04 (1)
3, 4, 5, 6, 7, 10, 11, 12, 14, 15, 16, 18 1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 27-39 -224 / 0 0.04 (2) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
3 TMW+w MT20 2.0 4.0 2- 3 -33 / 0 -109.0 -109.0 0.12 (1) 6.25 28-40 -217 / 0 0.04 (2) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
8 TS-t MT20 3.0 6.0 3- 4 -25 / 0 -109.0 -109.0 0.08 (2) 6.25 30-45 -225 / 0 0.04 (1) LIVE LOAD
9 TMTW+m MT20 4.0 6.0 2.75 2.00 4- 5 -13 / 2 -109.0 -109.0 0.05 (2) 6.25 31- 9 -222 / 0 0.19 (2)
13 TTW-p MT20 4.0 6.0 5- 6 -11 / 2 -109.0 -109.0 0.05 (2) 6.25 32- 7 -211 / 0 0.13 (2)
17 TMTW+m MT20 4.0 6.0 2.75 2.00 6- 7 -8 / 3 -109.0 -109.0 0.05 (2) 10.00 33- 6 -217 / 0 0.09 (1) CSI: TC=0.12/1.00 (2-3:1) , BC=0.03/1.00 (36-37:8) ,
19 TMV+p MT20 2.0 4.0 7- 8 -4 / 3 -109.0 -109.0 0.05 (2) 10.00 34- 5 -220 / 0 0.06 (2) WB=0.19/1.00 (17-22:3) , SSI=0.12/1.00 (2-3:1)
20 BMV1+p MT20 2.0 4.0 8- 9 -4 / 3 -109.0 -109.0 0.05 (2) 10.00 35- 4 -199 / 0 0.04 (1)
21, 22, 23, 24, 26, 27, 28, 30, 31, 32, 33, 34, 35, 36 9-10 -3 / 3 -109.0 -109.0 0.05 (1) 10.00 36- 3 -268 / 0 0.04 (2) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
21 BMW1+w MT20 2.0 4.0 10-11 -4 / 3 -109.0 -109.0 0.06 (1) 10.00 25-41 -223 / 0 0.05 (3) COMP=1.10 SHEAR=1.10 TENS= 1.10
25 BSW1+l MT20 4.0 6.0 11-12 -4 / 3 -109.0 -109.0 0.06 (2) 10.00 24-42 -220 / 0 0.04 (3)
29 BS-t MT20 3.0 6.0 12-13 -4 / 7 -109.0 -109.0 0.06 (1) 10.00 23-43 -225 / 0 0.04 (3) COMPANION LIVE LOAD FACTOR = 1.00
37 BMV1+p MT20 2.0 4.0 13-14 0/3 -109.0 -109.0 0.06 (3) 10.00 22-17 -221 / 0 0.19 (3)
38, 39, 40, 41, 42, 43, 45 14-15 0/0 -109.0 -109.0 0.06 (3) 10.00 21-18 -222 / 0 0.14 (3)
38 TMWW+t MT20 3.0 8.0 15-16 0/1 -109.0 -109.0 0.06 (3) 10.00 45-10 -225 / 0 0.04 (1) TRUSS PLATE MANUFACTURER IS NOT
44 NP-p MT20 2.0 4.0 16-17 0/3 -109.0 -109.0 0.05 (3) 10.00 40-11 -217 / 0 0.04 (2) RESPONSIBLE FOR QUALITY CONTROL IN THE
17-18 0/0 -109.0 -109.0 0.05 (3) 10.00 39-12 -224 / 0 0.04 (2) TRUSS MANUFACTURING PLANT .
18-19 0/4 -109.0 -109.0 0.05 (3) 10.00 38-13 -223 / 0 0.00 (1)
20-19 -89 / 0 0.0 0.0 0.03 (3) 7.81 41-14 -223 / 0 0.05 (3) NAIL VALUES
42-15 -220 / 0 0.04 (3) PLATE GRIP(DRY) SHEAR SECTION
37-36 0 / 26 -18.5 -18.5 0.03 (8) 10.00 43-16 -225 / 0 0.04 (3) (PSI) (PLI) (PLI)
36-35 0 / 18 -18.5 -18.5 0.03 (8) 10.00 MAX MIN MAX MIN MAX MIN
35-34 -1 / 13 -18.5 -18.5 0.02 (8) 10.00 MT20 650 371 1747 788 1987 1873
34-33 -2 / 10 -18.5 -18.5 0.02 (8) 10.00
33-32 -2 / 7 -18.5 -18.5 0.01 (8) 10.00 PLATE PLACEMENT TOL. = 0.250 inches
32-31 -3 / 5 -18.5 -18.5 0.01 (8) 10.00
31-30 -3 / 1 -18.5 -18.5 0.01 (8) 10.00 PLATE ROTATION TOL. = 5.0 Deg.
30-29 -3 / 0 -18.5 -18.5 0.01 (8) 10.00
29-28 -3 / 0 -18.5 -18.5 0.01 (8) 10.00 JSI GRIP= 0.45 (19) (INPUT = 0.90 )
28-27 -3 / 0 -18.5 -18.5 0.01 (8) 10.00 JSI METAL= 0.14 (2) (INPUT = 1.00 )
27-26 -3 / 0 -18.5 -18.5 0.02 (8) 10.00
26-25 -3 / 0 -18.5 -18.5 0.02 (8) 10.00
25-24 -4 / 0 -18.5 -18.5 0.02 (8) 10.00
24-23 -4 / 0 -18.5 -18.5 0.01 (8) 10.00
23-22 -4 / 0 -18.5 -18.5 0.01 (8) 10.00
22-21 0/0 -18.5 -18.5 0.02 (8) 10.00
21-20 0/3 -18.5 -18.5 0.02 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A AGF2 6 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:35 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-z97ufLfqmiM4_3iCi7Bhwp4sHrfMp3kIxP3eOqzRBRI
10-8 3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 3-0-0
4x6 Scale: 1/8"=1'
5.75 12
13
12 14
11 15
4x6 T2 T2 4x6
3x8 10 16
W2 W1 W2
9 W3 W3 17 3x8
W4 T3 T4 W450
8 52 53 54 55 48 49 18
7 19
11-0-0

6 4x8 4x8 4x8 4x8 4x8 4x8 4x8 20


5 21

7-0-0
4 T1 T5 22
ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6
3 ST5 ST5 23
ST4 ST4
ST3 ST3
ST2 ST2 24
12 ST1 ST1
11-4

W5 W5

11-4
B1 B2 B1

47 46 45 44 43 42 41 40 38 37 36 35 34 32 31 30 29 28 27 26 25
39 33
3x8 42-10-8 3x8

3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 3-0-0
42-0-0

TOTAL WEIGHT = 6 X 211 = 1267 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
47 - 2 2x3 DRY No.2 SPF SPECIFIED LOADS:
1 - 8 2x4 DRY No.2 SPF THIS TRUSS DESIGNED FOR CONTINUOUS BEARINGS. TOP CH. LL = 31.3 PSF
8 - 13 2x4 DRY No.2 SPF DL = 6.0 PSF
13 - 18 2x4 DRY No.2 SPF THIS TRUSS REQUIRES RIGID SHEATHING ON EXPOSED FACE. BOT CH. LL = 0.0 PSF
18 - 24 2x4 DRY No.2 SPF DL = 7.4 PSF
25 - 24 2x3 DRY No.2 SPF BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) TOTAL LOAD = 44.7 PSF
47 - 39 2x4 DRY No.2 SPF
39 - 33 2x4 DRY No.2 SPF BRACING SPACING = 24.0 IN. C/C
33 - 25 2x4 DRY No.2 SPF TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL WEBS 2x3 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
ALL GABLE WEBS ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015
2x3 DRY No.2 SPF
DRY: SEASONED LUMBER. LOADING THIS DESIGN COMPLIES WITH:
TOTAL LOAD CASES: (8) - PART 9 OF BCBC 2018 , ABC 2019
GABLE STUDS SPACED AT 2-0-0 OC. - PART 9 OF OBC 2012 (2019 AMENDMENT)
CHORDS WEBS - CSA 086-14
MAX. FACTORED FACTORED MAX. FACTORED - TPIC 2014
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DESIGN ASSUMPTIONS
PLATES (table is in inches) FR-TO FROM TO LENGTH FR-TO -OVERHANG NOT TO BE ALTERED OR CUT OFF.
JT TYPE PLATES W LEN Y X 47- 2 -301 / 0 0.0 0.0 0.05 (1) 7.81 36-55 -193 / 0 0.03 (1)
2 TMV+p MT20 2.0 4.0 1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 37-54 -223 / 0 0.04 (2) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
3, 4, 5, 6, 7, 10, 11, 12, 14, 15, 16, 19, 20, 21, 22, 23 2- 3 -70 / 0 -109.0 -109.0 0.12 (1) 6.25 38-53 -217 / 0 0.04 (2) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMW+w MT20 2.0 4.0 3- 4 -62 / 0 -109.0 -109.0 0.08 (1) 6.25 40-52 -225 / 0 0.04 (2) LIVE LOAD
8 TS-t MT20 3.0 8.0 4- 5 -50 / 0 -109.0 -109.0 0.05 (1) 6.25 41- 9 -221 / 0 0.19 (2)
9 TMTW+m MT20 4.0 6.0 2.75 2.00 5- 6 -48 / 0 -109.0 -109.0 0.05 (1) 6.25 42- 7 -211 / 0 0.13 (1)
13 TTW-p MT20 4.0 6.0 6- 7 -45 / 0 -109.0 -109.0 0.05 (1) 6.25 43- 6 -217 / 0 0.09 (2) CSI: TC=0.12/1.00 (2-3:1) , BC=0.04/1.00 (25-26:8) ,
17 TMTW+m MT20 4.0 6.0 2.75 2.00 7- 8 -41 / 0 -109.0 -109.0 0.05 (2) 6.25 44- 5 -220 / 0 0.06 (1) WB=0.19/1.00 (17-31:3) , SSI=0.12/1.00 (23-24:3)
18 TS-t MT20 3.0 8.0 8- 9 -41 / 0 -109.0 -109.0 0.05 (2) 6.25 45- 4 -199 / 0 0.04 (2)
24 TMV+p MT20 2.0 4.0 9-10 -39 / 0 -109.0 -109.0 0.05 (2) 6.25 46- 3 -268 / 0 0.04 (1) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
25 BMV1+p MT20 2.0 4.0 10-11 -41 / 0 -109.0 -109.0 0.06 (1) 6.25 35-48 -222 / 0 0.04 (3) COMP=1.10 SHEAR=1.10 TENS= 1.10
26, 27, 28, 29, 30, 31, 32, 34, 35, 36, 37, 38, 40, 41, 42, 43, 11-12 -41 / 0 -109.0 -109.0 0.06 (2) 6.25 34-49 -218 / 0 0.04 (3)
44, 45, 46 12-13 -37 / 0 -109.0 -109.0 0.06 (2) 6.25 32-50 -225 / 0 0.04 (3) COMPANION LIVE LOAD FACTOR = 1.00
26 BMW1+w MT20 2.0 4.0 13-14 -37 / 0 -109.0 -109.0 0.05 (3) 6.25 31-17 -222 / 0 0.19 (3)
33 BS-t MT20 3.0 8.0 14-15 -41 / 0 -109.0 -109.0 0.06 (3) 6.25 30-19 -211 / 0 0.13 (1)
39 BS-t MT20 3.0 8.0 15-16 -41 / 0 -109.0 -109.0 0.06 (1) 6.25 29-20 -217 / 0 0.09 (1) TRUSS PLATE MANUFACTURER IS NOT
47 BMV1+p MT20 2.0 4.0 16-17 -39 / 0 -109.0 -109.0 0.05 (3) 6.25 28-21 -222 / 0 0.06 (3) RESPONSIBLE FOR QUALITY CONTROL IN THE
48, 49, 50, 52, 53, 54, 55 17-18 -41 / 0 -109.0 -109.0 0.05 (3) 6.25 27-22 -188 / 0 0.04 (1) TRUSS MANUFACTURING PLANT .
48 TMWW+t MT20 4.0 8.0 18-19 -41 / 0 -109.0 -109.0 0.05 (3) 6.25 26-23 -301 / 0 0.05 (3)
51 NP-p MT20 2.0 4.0 19-20 -45 / 0 -109.0 -109.0 0.05 (1) 6.25 52-10 -225 / 0 0.04 (1) NAIL VALUES
20-21 -48 / 0 -109.0 -109.0 0.05 (3) 6.25 53-11 -217 / 0 0.04 (1) PLATE GRIP(DRY) SHEAR SECTION
21-22 -49 / 0 -109.0 -109.0 0.05 (3) 6.25 54-12 -223 / 0 0.04 (2) (PSI) (PLI) (PLI)
22-23 -66 / 0 -109.0 -109.0 0.10 (3) 6.25 55-13 -193 / 0 0.00 (3) MAX MIN MAX MIN MAX MIN
23-24 -61 / 0 -109.0 -109.0 0.10 (3) 6.25 48-14 -222 / 0 0.04 (3) MT20 650 371 1747 788 1987 1873
25-24 -176 / 0 0.0 0.0 0.10 (1) 7.81 49-15 -218 / 0 0.04 (3)
50-16 -225 / 0 0.04 (1) PLATE PLACEMENT TOL. = 0.250 inches
47-46 0 / 59 -18.5 -18.5 0.03 (8) 10.00
46-45 0 / 50 -18.5 -18.5 0.03 (8) 10.00 PLATE ROTATION TOL. = 5.0 Deg.
45-44 0 / 46 -18.5 -18.5 0.02 (8) 10.00
44-43 0 / 43 -18.5 -18.5 0.02 (8) 10.00 JSI GRIP= 0.45 (24) (INPUT = 0.90 )
43-42 0 / 40 -18.5 -18.5 0.02 (8) 10.00 JSI METAL= 0.17 (2) (INPUT = 1.00 )
42-41 0 / 38 -18.5 -18.5 0.02 (8) 10.00
41-40 0 / 34 -18.5 -18.5 0.02 (8) 10.00
40-39 0 / 34 -18.5 -18.5 0.02 (8) 10.00
39-38 0 / 34 -18.5 -18.5 0.02 (8) 10.00
38-37 0 / 34 -18.5 -18.5 0.02 (8) 10.00
37-36 0 / 33 -18.5 -18.5 0.02 (8) 10.00
36-35 0 / 33 -18.5 -18.5 0.02 (8) 10.00
35-34 0 / 34 -18.5 -18.5 0.02 (8) 10.00
34-33 0 / 34 -18.5 -18.5 0.02 (8) 10.00
33-32 0 / 34 -18.5 -18.5 0.02 (8) 10.00
32-31 0 / 34 -18.5 -18.5 0.02 (8) 10.00
31-30 0 / 38 -18.5 -18.5 0.02 (8) 10.00
30-29 0 / 40 -18.5 -18.5 0.02 (8) 10.00
29-28 0 / 43 -18.5 -18.5 0.02 (8) 10.00
28-27 0 / 47 -18.5 -18.5 0.02 (8) 10.00
27-26 0 / 50 -18.5 -18.5 0.04 (8) 10.00
26-25 0 / 60 -18.5 -18.5 0.04 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A AGF3 4 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:36 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-RLhHshfSX0VxbDHPFriwT1d11F_fYW?S93oCxHzRBRH
10-8 3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 1-0-0
4x6 Scale: 1/8"=1'
5.75 12
13
12 14
11 15
4x6 T2 T2 4x6
3x6 10 16
W2 W1 W2
9 W3 W3 17 3x6
W4 T3 T4 W451
8 53 54 55 48 49 50 18
7 19
11-0-0

6 3x8 3x8 3x8 3x8 3x8 3x8 3x8 20


5 21
T5

7-0-0
4 T1 22
ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6 ST6
ST5 ST5
3 ST4 ST4 ST123
ST3 ST3 24
ST2 ST2

1-10-12
12 ST1 W5
11-4

W6
B1 B2 B1

47 46 45 44 43 42 41 40 38 37 36 35 33 32 31 30 29 28 27 26 25
39 34
10-8 3x6 40-0-0 3x6

3-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 2-0-0 1-0-0
40-0-0

TOTAL WEIGHT = 4 X 207 = 829 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
47 - 2 2x3 DRY No.2 SPF SPECIFIED LOADS:
1 - 8 2x4 DRY No.2 SPF THIS TRUSS DESIGNED FOR CONTINUOUS BEARINGS. TOP CH. LL = 31.3 PSF
8 - 13 2x4 DRY No.2 SPF DL = 6.0 PSF
13 - 18 2x4 DRY No.2 SPF THIS TRUSS REQUIRES RIGID SHEATHING ON EXPOSED FACE. BOT CH. LL = 0.0 PSF
18 - 24 2x4 DRY No.2 SPF DL = 7.4 PSF
25 - 24 2x3 DRY No.2 SPF BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) TOTAL LOAD = 44.7 PSF
47 - 39 2x4 DRY No.2 SPF
39 - 34 2x4 DRY No.2 SPF BRACING SPACING = 24.0 IN. C/C
34 - 25 2x4 DRY No.2 SPF TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL WEBS 2x3 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
ALL GABLE WEBS ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015
2x3 DRY No.2 SPF
DRY: SEASONED LUMBER. LOADING THIS DESIGN COMPLIES WITH:
TOTAL LOAD CASES: (8) - PART 9 OF BCBC 2018 , ABC 2019
GABLE STUDS SPACED AT 2-0-0 OC. - PART 9 OF OBC 2012 (2019 AMENDMENT)
CHORDS WEBS - CSA 086-14
MAX. FACTORED FACTORED MAX. FACTORED - TPIC 2014
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DESIGN ASSUMPTIONS
PLATES (table is in inches) FR-TO FROM TO LENGTH FR-TO -OVERHANG NOT TO BE ALTERED OR CUT OFF.
JT TYPE PLATES W LEN Y X 47- 2 -286 / 0 0.0 0.0 0.03 (2) 7.81 36-48 -225 / 0 0.04 (1)
2 TMV+p MT20 2.0 4.0 1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 37-55 -224 / 0 0.04 (2) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
3, 4, 5, 6, 7, 10, 11, 12, 14, 15, 16, 19, 20, 21, 22, 23 2- 3 -35 / 3 -109.0 -109.0 0.12 (1) 6.25 38-54 -217 / 0 0.04 (1) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMW+w MT20 2.0 4.0 3- 4 -28 / 4 -109.0 -109.0 0.08 (2) 6.25 40-53 -225 / 0 0.04 (1) LIVE LOAD
8 TS-t MT20 3.0 6.0 4- 5 -16 / 6 -109.0 -109.0 0.05 (2) 6.25 41- 9 -222 / 0 0.19 (1)
9 TMTW+m MT20 4.0 6.0 2.75 2.00 5- 6 -13 / 6 -109.0 -109.0 0.05 (2) 6.25 42- 7 -211 / 0 0.13 (2)
13 TTW-p MT20 4.0 6.0 6- 7 -10 / 7 -109.0 -109.0 0.05 (2) 6.25 43- 6 -217 / 0 0.09 (1) CSI: TC=0.12/1.00 (2-3:1) , BC=0.03/1.00 (46-47:8) ,
17 TMTW+m MT20 4.0 6.0 2.75 2.00 7- 8 -7 / 7 -109.0 -109.0 0.05 (2) 10.00 44- 5 -220 / 0 0.06 (2) WB=0.19/1.00 (9-41:1) , SSI=0.12/1.00 (2-3:1)
18 TS-t MT20 3.0 6.0 8- 9 -7 / 7 -109.0 -109.0 0.05 (2) 10.00 45- 4 -199 / 0 0.04 (1)
24 TMV+p MT20 2.0 4.0 9-10 -5 / 8 -109.0 -109.0 0.05 (1) 10.00 46- 3 -268 / 0 0.04 (2) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
25 BMV1+p MT20 2.0 4.0 10-11 -7 / 7 -109.0 -109.0 0.06 (1) 10.00 35-49 -225 / 0 0.04 (3) COMP=1.10 SHEAR=1.10 TENS= 1.10
26, 27, 28, 29, 30, 31, 32, 33, 35, 36, 37, 38, 40, 41, 42, 43, 11-12 -6 / 8 -109.0 -109.0 0.06 (2) 10.00 33-50 -217 / 0 0.04 (3)
44, 45, 46 12-13 -7 / 11 -109.0 -109.0 0.06 (1) 10.00 32-51 -226 / 0 0.04 (3) COMPANION LIVE LOAD FACTOR = 1.00
26 BMW1+w MT20 2.0 4.0 13-14 0/5 -109.0 -109.0 0.06 (3) 10.00 31-17 -221 / 0 0.19 (3)
34 BS-t MT20 3.0 6.0 14-15 -3 / 4 -109.0 -109.0 0.06 (3) 10.00 30-19 -211 / 0 0.13 (1)
39 BS-t MT20 3.0 6.0 15-16 -3 / 4 -109.0 -109.0 0.06 (3) 10.00 29-20 -218 / 0 0.09 (3) TRUSS PLATE MANUFACTURER IS NOT
47 BMV1+p MT20 2.0 4.0 16-17 -2 / 6 -109.0 -109.0 0.05 (3) 10.00 28-21 -214 / 0 0.06 (3) RESPONSIBLE FOR QUALITY CONTROL IN THE
48, 49, 50, 51, 53, 54, 55 17-18 -3 / 4 -109.0 -109.0 0.05 (3) 10.00 27-22 -225 / 0 0.04 (1) TRUSS MANUFACTURING PLANT .
48 TMWW+t MT20 3.0 8.0 18-19 -3 / 4 -109.0 -109.0 0.05 (3) 10.00 26-23 -162 / 0 0.03 (3)
52 NP-p MT20 2.0 4.0 19-20 -3 / 0 -109.0 -109.0 0.05 (1) 10.00 53-10 -225 / 0 0.04 (2) NAIL VALUES
20-21 -4 / 0 -109.0 -109.0 0.05 (1) 10.00 54-11 -217 / 0 0.04 (2) PLATE GRIP(DRY) SHEAR SECTION
21-22 -9 / 0 -109.0 -109.0 0.05 (1) 10.00 55-12 -224 / 0 0.04 (2) (PSI) (PLI) (PLI)
22-23 -10 / 0 -109.0 -109.0 0.05 (1) 6.25 48-13 -225 / 0 0.00 (1) MAX MIN MAX MIN MAX MIN
23-24 -15 / 0 -109.0 -109.0 0.03 (3) 6.25 49-14 -225 / 0 0.04 (3) MT20 650 371 1747 788 1987 1873
25-24 -49 / 0 0.0 0.0 0.04 (1) 7.81 50-15 -217 / 0 0.04 (3)
51-16 -225 / 0 0.04 (1) PLATE PLACEMENT TOL. = 0.250 inches
47-46 -4 / 28 -18.5 -18.5 0.03 (8) 10.00
46-45 -5 / 19 -18.5 -18.5 0.03 (8) 10.00 PLATE ROTATION TOL. = 5.0 Deg.
45-44 -5 / 15 -18.5 -18.5 0.02 (8) 10.00
44-43 -6 / 12 -18.5 -18.5 0.02 (8) 10.00 JSI GRIP= 0.45 (24) (INPUT = 0.90 )
43-42 -6 / 9 -18.5 -18.5 0.01 (8) 10.00 JSI METAL= 0.14 (2) (INPUT = 1.00 )
42-41 -7 / 7 -18.5 -18.5 0.01 (8) 10.00
41-40 -7 / 3 -18.5 -18.5 0.01 (8) 10.00
40-39 -7 / 3 -18.5 -18.5 0.01 (8) 10.00
39-38 -7 / 3 -18.5 -18.5 0.01 (8) 10.00
38-37 -7 / 3 -18.5 -18.5 0.02 (8) 10.00
37-36 -7 / 2 -18.5 -18.5 0.01 (8) 10.00
36-35 -7 / 2 -18.5 -18.5 0.01 (8) 10.00
35-34 -7 / 2 -18.5 -18.5 0.01 (8) 10.00
34-33 -7 / 2 -18.5 -18.5 0.01 (8) 10.00
33-32 -6 / 2 -18.5 -18.5 0.01 (8) 10.00
32-31 -6 / 2 -18.5 -18.5 0.01 (8) 10.00
31-30 -3 / 3 -18.5 -18.5 0.01 (8) 10.00
30-29 0/3 -18.5 -18.5 0.01 (8) 10.00
29-28 0/4 -18.5 -18.5 0.01 (8) 10.00
28-27 0/7 -18.5 -18.5 0.02 (8) 10.00
27-26 0 / 12 -18.5 -18.5 0.02 (8) 10.00
26-25 0 / 17 -18.5 -18.5 0.02 (1) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A B 8 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:37 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-vXEf41g4IJdoDNsbpYD9?EA?Le7EHpsbOjYlTjzRBRG
10-8 6-9-11 6-7-3 6-7-3 6-7-3 6-7-3 6-9-11 10-8
4x6 Scale = 1:89.7
5.75 12
6

3x4 T2 T2 3x4
3x6
5 7 3x6
4 8
10-6-4

4x8 4x8
3 W2 W1 W2 9
T1 T1
W3 W3
8x10 W5 W5
W4 W4 10
12 11
11-4

W6 W6

11-4
B1 B2 B1
17 16 14 13
18 15 12
3x4 4x6 6x6 4x6 3x4 8x10
10-8 40-0-0 10-8
10-1-4 9-10-12 9-10-12 10-1-4
40-0-0

TOTAL WEIGHT = 8 X 160 = 1282 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 8 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 11 2x4 DRY No.2 SPF 18 2652 0 2652 0 0 5-8 2-14 BOT CH. LL = 0.0 PSF
18 - 2 2x4 DRY No.2 SPF 12 2652 0 2652 0 0 5-8 2-14 DL = 7.4 PSF
12 - 10 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
18 - 16 2x4 DRY No.2 SPF
16 - 14 2x4 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
14 - 12 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL WEBS 2x3 DRY No.2 SPF 18 1859 1312 / 0 0/0 0/0 0/0 547 / 0 0/0 SMALL BUILDING REQUIREMENTS OF PART 9,
EXCEPT 12 1859 1312 / 0 0/0 0/0 0/0 547 / 0 0/0 NBCC 2015
18 - 3 2x4 DRY No.2 SPF
9 - 12 2x4 DRY No.2 SPF BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 18, 12 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , ABC 2019
DRY: SEASONED LUMBER. BRACING - PART 9 OF OBC 2012 (2019 AMENDMENT)
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 2.83 FT. - CSA 086-14
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. - TPIC 2014

ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
PLATES (table is in inches) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
JT TYPE PLATES W LEN Y X 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 7-15, 5-15. DBS = 20-0-0 . CBF = LIVE LOAD
2, 10, 12, 18 147 LBS.
2 2 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 3 LENGTH OF 3-18, 9-12. DBS = 10-0-0 . CBF = ALLOWABLE DEFL.(LL)= L/360 (1.33")
2 TMBMVW1*+mMT20 8.0 10.0 Edge 2.50 273 LBS. CALCULATED VERT. DEFL.(LL) = L/ 999 (0.27")
3 TMWW-t MT20 4.0 8.0 1.75 2.75 ALLOWABLE DEFL.(TL)= L/360 (1.33")
4 TS-t MT20 3.0 6.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). CALCULATED VERT. DEFL.(TL) = L/ 910 (0.53")
5 TMWW+t MT20 3.0 4.0 1.75 1.00 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4,
6 TTW+p MT20 4.0 6.0 Edge 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12. CSI: TC=0.92/1.00 (7-9:1) , BC=0.84/1.00 (17-18:1) ,
7 TMWW+t MT20 3.0 4.0 1.75 1.00 WB=0.79/1.00 (5-15:2) , SSI=0.31/1.00 (9-10:3)
8 TS-t MT20 3.0 6.0 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN
9 TMWW-t MT20 4.0 8.0 1.75 2.75 THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
12 TMBMVW1*+mMT20 8.0 10.0 Edge 2.50 COMP=1.10 SHEAR=1.10 TENS= 1.10
13 BMWW+t MT20 3.0 4.0 LOADING
14 BS-t MT20 4.0 6.0 TOTAL LOAD CASES: (8) COMPANION LIVE LOAD FACTOR = 1.00
15 BMWWW-t MT20 6.0 6.0
16 BS-t MT20 4.0 6.0 CHORDS WEBS
17 BMWW+t MT20 3.0 4.0 MAX. FACTORED FACTORED MAX. FACTORED TRUSS PLATE MANUFACTURER IS NOT
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX RESPONSIBLE FOR QUALITY CONTROL IN THE
Edge - INDICATES REFERENCE CORNER OF PLATE (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) TRUSS MANUFACTURING PLANT .
TOUCHES EDGE OF CHORD. FR-TO FROM TO LENGTH FR-TO
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 15- 6 0 / 1828 0.41 (1) NAIL VALUES
2- 3 0 / 30 -109.0 -109.0 0.63 (2) 10.00 15- 7 -1173 / 0 0.79 (3) PLATE GRIP(DRY) SHEAR SECTION
3- 4 -3906 / 0 -109.0 -109.0 0.92 (1) 2.83 7-13 0 / 630 0.14 (3) (PSI) (PLI) (PLI)
4- 5 -3906 / 0 -109.0 -109.0 0.92 (1) 2.83 13- 9 -486 / 57 0.22 (3) MAX MIN MAX MIN MAX MIN
5- 6 -2813 / 0 -109.0 -109.0 0.76 (1) 3.36 5-15 -1173 / 0 0.79 (2) MT20 650 371 1747 788 1987 1873
6- 7 -2813 / 0 -109.0 -109.0 0.76 (1) 3.36 17- 5 0 / 630 0.14 (2)
7- 8 -3906 / 0 -109.0 -109.0 0.92 (1) 2.83 3-17 -486 / 57 0.22 (2) PLATE PLACEMENT TOL. = 0.250 inches
8- 9 -3906 / 0 -109.0 -109.0 0.92 (1) 2.83 18- 3 -4376 / 0 0.70 (1)
9-10 0 / 30 -109.0 -109.0 0.63 (3) 10.00 9-12 -4376 / 0 0.70 (1) PLATE ROTATION TOL. = 5.0 Deg.
10-11 0 / 22 -109.0 -109.0 0.07 (1) 10.00
18- 2 -399 / 0 0.0 0.0 0.04 (1) 7.81 JSI GRIP= 0.89 (3) (INPUT = 0.90 )
12-10 -399 / 0 0.0 0.0 0.04 (1) 7.81 JSI METAL= 0.83 (2) (INPUT = 1.00 )

18-17 0 / 3796 -18.5 -18.5 0.84 (1) 10.00


17-16 0 / 3282 -18.5 -18.5 0.76 (1) 10.00
16-15 0 / 3282 -18.5 -18.5 0.76 (1) 10.00
15-14 0 / 3282 -18.5 -18.5 0.76 (1) 10.00
14-13 0 / 3282 -18.5 -18.5 0.76 (1) 10.00
13-12 0 / 3796 -18.5 -18.5 0.84 (1) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A CGF 3 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:37 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-vXEf41g4IJdoDNsbpYD9?EACUeK6Hz?bOjYlTjzRBRG
10-8 5-9-0 5-9-0 10-8
4x6 Scale = 1:52.9

10.75 12
6
4

T1 T1

6-6-1
ST3 7
3
ST2 ST2

2 ST1 ST1 8
9

1-4-4

1-4-4
1 W1 W1
B1

10-8 12-4-8
16 15 14 13 12 11 10
11-6-0
11-6-0

TOTAL WEIGHT = 3 X 51 = 152 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
16 - 2 2x3 DRY No.2 SPF SPECIFIED LOADS:
1 - 5 2x4 DRY No.2 SPF THIS TRUSS DESIGNED FOR CONTINUOUS BEARINGS. TOP CH. LL = 31.3 PSF
5 - 9 2x4 DRY No.2 SPF DL = 6.0 PSF
10 - 8 2x3 DRY No.2 SPF THIS TRUSS REQUIRES RIGID SHEATHING ON EXPOSED FACE. BOT CH. LL = 0.0 PSF
16 - 10 2x4 DRY No.2 SPF DL = 7.4 PSF
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) TOTAL LOAD = 44.7 PSF
ALL WEBS 2x3 DRY No.2 SPF
ALL GABLE WEBS BRACING SPACING = 24.0 IN. C/C
2x3 DRY No.2 SPF TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
DRY: SEASONED LUMBER. MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
SMALL BUILDING REQUIREMENTS OF PART 9,
GABLE STUDS SPACED AT 2-0-0 OC. ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015

LOADING THIS DESIGN COMPLIES WITH:


TOTAL LOAD CASES: (8) - PART 9 OF BCBC 2018 , ABC 2019
- PART 9 OF OBC 2012 (2019 AMENDMENT)
PLATES (table is in inches) CHORDS WEBS - CSA 086-14
JT TYPE PLATES W LEN Y X MAX. FACTORED FACTORED MAX. FACTORED - TPIC 2014
2 TMV+p MT20 2.0 4.0 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
3, 4, 6, 7 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DESIGN ASSUMPTIONS
3 TMW+w MT20 2.0 4.0 FR-TO FROM TO LENGTH FR-TO -OVERHANG NOT TO BE ALTERED OR CUT OFF.
5 TTW+p MT20 4.0 6.0 Edge 16- 2 -213 / 0 0.0 0.0 0.04 (1) 7.81 13- 5 -208 / 0 0.14 (1)
8 TMV+p MT20 2.0 4.0 1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 14- 4 -234 / 0 0.08 (2) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
10 BMV1+p MT20 2.0 4.0 2- 3 -29 / 0 -109.0 -109.0 0.04 (1) 6.25 15- 3 -192 / 0 0.03 (1) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
11, 12, 13, 14, 15 3- 4 -19 / 0 -109.0 -109.0 0.06 (2) 6.25 12- 6 -234 / 0 0.08 (3) LIVE LOAD
11 BMW1+w MT20 2.0 4.0 4- 5 -16 / 0 -109.0 -109.0 0.06 (2) 6.25 11- 7 -192 / 0 0.03 (1)
16 BMV1+p MT20 2.0 4.0 5- 6 -16 / 0 -109.0 -109.0 0.06 (3) 6.25
6- 7 -19 / 0 -109.0 -109.0 0.06 (3) 6.25 CSI: TC=0.08/1.00 (1-2:1) , BC=0.02/1.00 (15-16:1) ,
Edge - INDICATES REFERENCE CORNER OF PLATE 7- 8 -29 / 0 -109.0 -109.0 0.04 (1) 6.25 WB=0.14/1.00 (5-13:1) , SSI=0.07/1.00 (4-5:2)
TOUCHES EDGE OF CHORD. 8- 9 0 / 35 -109.0 -109.0 0.08 (1) 10.00
10- 8 -213 / 0 0.0 0.0 0.04 (1) 7.81 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
COMP=1.10 SHEAR=1.10 TENS= 1.10
16-15 0 / 24 -18.5 -18.5 0.02 (1) 10.00
15-14 0 / 16 -18.5 -18.5 0.02 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00
14-13 0 / 11 -18.5 -18.5 0.02 (8) 10.00
13-12 0 / 11 -18.5 -18.5 0.02 (8) 10.00
12-11 0 / 16 -18.5 -18.5 0.02 (8) 10.00 TRUSS PLATE MANUFACTURER IS NOT
11-10 0 / 24 -18.5 -18.5 0.02 (1) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING NAIL VALUES


AS PER NBCC 4.1.6.2.(8) PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.18 (8) (INPUT = 0.90 )


JSI METAL= 0.13 (8) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A D 5 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:38 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Oko1HNhj3dlerXRnNGkOYSiI62dM0KWkdNHI?9zRBRF
5-2-12 5-0-4 4-10-15 5-1-7
4x6 Scale = 1:98.5

10.75 12
3x4 3x4
2 T1 4
T2

10-6-7
W1
4x6
4x6
W2 W3 5
1 W5 W4

1-6-10
1-4-4
W9 W8
W7 B1 W6
8
11 10 9 7 6
2x4 4x4 4x6 3x6 2x4
20-3-6 4x4
5-2-12 5-0-4 4-10-15 5-1-7
20-3-6

TOTAL WEIGHT = 5 X 94 = 470 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 3 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
3 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
11 - 1 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
6 - 5 2x4 DRY No.2 SPF 11 1293 0 1293 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
11 - 8 2x4 DRY No.2 SPF 6 1293 0 1293 0 0 3-6 1-8 DL = 7.4 PSF
8 - 6 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. 11 907 635 / 0 0/0 0/0 0/0 272 / 0 0/0 SMALL BUILDING REQUIREMENTS OF PART 9,
6 907 635 / 0 0/0 0/0 0/0 272 / 0 0/0 NBCC 2015

BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 11, 6 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , ABC 2019
PLATES (table is in inches) BRACING - PART 9 OF OBC 2012 (2019 AMENDMENT)
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 5.30 FT. - CSA 086-14
1 TMVW-t MT20 4.0 6.0 1.50 Edge MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. - TPIC 2014
2 TMWW-t MT20 3.0 4.0 1.50 1.25
3 TTW+p MT20 4.0 6.0 Edge ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
4 TMWW-t MT20 3.0 4.0 1.50 1.25 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
5 TMVW-t MT20 4.0 6.0 1.50 Edge LOADING LIVE LOAD
6 BMV1+p MT20 2.0 4.0 TOTAL LOAD CASES: (8)
7 BMWW-t MT20 4.0 4.0 2.00 1.50 ALLOWABLE DEFL.(LL)= L/360 (0.68")
8 BS-t MT20 3.0 6.0 CHORDS WEBS CALCULATED VERT. DEFL.(LL) = L/ 999 (0.03")
9 BMWWW-t MT20 4.0 6.0 MAX. FACTORED FACTORED MAX. FACTORED ALLOWABLE DEFL.(TL)= L/360 (0.68")
10 BMWW-t MT20 4.0 4.0 2.00 1.75 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX CALCULATED VERT. DEFL.(TL) = L/ 999 (0.06")
11 BMV1+p MT20 2.0 4.0 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC)
FR-TO FROM TO LENGTH FR-TO CSI: TC=0.40/1.00 (1-2:1) , BC=0.21/1.00 (9-10:1) ,
Edge - INDICATES REFERENCE CORNER OF PLATE 1- 2 -1230 / 0 -109.0 -109.0 0.40 (1) 5.30 10- 2 -79 / 67 0.04 (1) WB=0.57/1.00 (2-9:2) , SSI=0.20/1.00 (1-2:2)
TOUCHES EDGE OF CHORD. 2- 3 -913 / 0 -109.0 -109.0 0.38 (1) 5.95 2- 9 -490 / 0 0.57 (2)
3- 4 -912 / 0 -109.0 -109.0 0.36 (1) 5.98 9- 3 0 / 753 0.17 (1) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
4- 5 -1189 / 0 -109.0 -109.0 0.38 (1) 5.40 9- 4 -460 / 0 0.53 (3) COMP=1.10 SHEAR=1.10 TENS= 1.10
11- 1 -1252 / 0 0.0 0.0 0.13 (1) 7.19 7- 4 -114 / 54 0.07 (1)
6- 5 -1253 / 0 0.0 0.0 0.13 (1) 7.18 1-10 0 / 967 0.22 (1) COMPANION LIVE LOAD FACTOR = 1.00
7- 5 0 / 943 0.21 (1)
11-10 0/0 -18.5 -18.5 0.12 (8) 10.00
10- 9 0 / 949 -18.5 -18.5 0.21 (1) 10.00 TRUSS PLATE MANUFACTURER IS NOT
9- 8 0 / 918 -18.5 -18.5 0.20 (1) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
8- 7 0 / 918 -18.5 -18.5 0.20 (1) 10.00 TRUSS MANUFACTURING PLANT .
7- 6 0/0 -18.5 -18.5 0.11 (8) 10.00
NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING (PSI) (PLI) (PLI)
AS PER NBCC 4.1.6.2.(8) MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.87 (10) (INPUT = 0.90 )


JSI METAL= 0.34 (1) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A DG1 1 3 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:38 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Oko1HNhj3dlerXRnNGkOYSiHs2TJ0HkkdNHI?9zRBRF
5-2-12 5-0-4 4-10-15 5-1-7
4x8 Scale = 1:98.5

10.75 12
4x6 4x6
2 T1 4
T2

10-6-7
O1 W1 O2
5x8 5x8
W2 W3 W4 5
1 W5

1-6-10
W9 W8

1-4-4
W7 B1 W6

8 Provide a 24" long 2x6 scab at joint 6,


11 10 9 7 6
one side, nailed to chord with 2 row of
6x8 6x8 6x10 4x6 3x4 3" common nails @ 3" o/c, (15 nails
20-3-6 7x8 min) 3-6 bearing.
5-2-12 5-0-4 4-10-15 5-1-7
20-3-6

TOTAL WEIGHT = 3 X 108 = 323 lb


***BEARING UNDERSIZED: 6***
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 3 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
3 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
11 - 1 2x6 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
6 - 5 2x6 DRY No.2 SPF 11 11207 0 11207 0 0 5-8 5-8 BOT CH. LL = 0.0 PSF
11 - 8 2x6 DRY No.2 SPF 6 11207 0 11207 0 0 3-6 6-10 DL = 7.4 PSF
8 - 6 2x6 DRY No.2 SPF TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL GIRDER TYPE: CStdGirder
DRY: SEASONED LUMBER. 11 7864 5508 / 0 0/0 0/0 0/0 2356 / 0 0/0 START DISTANCE = 0-0
6 7864 5508 / 0 0/0 0/0 0/0 2356 / 0 0/0 START SPAN CARRIED = 32-11-8
DESIGN CONSISTS OF 3 TRUSSES BUILT END DISTANCE = 20-3-6
SEPARATELY THEN FASTENED TOGETHER AS BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 11, 6 END SPAN CARRIED = 32-11-8
FOLLOWS: BEARING SIZE FACTOR = 1.15 AT JNT(S) 11 ( BASED ON SUPPORT DEPTH = 1-8 ) END WALL WIDTH = 3-6
APPLIED TO FRONT SIDE OF BOTTOM CHORD.
CHORDS #ROWS SURFACE LOAD(PLF) BRACING - ADDT'L LOADS BASED ON 55 % OF GSL.
SPACING (IN) TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.47 FT.
TOP CHORDS : (0.144"X3") NAILS MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
1- 3 1 12 TOP SMALL BUILDING REQUIREMENTS OF PART 9,
3- 5 1 12 TOP ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015
11- 1 2 12 TOP
6- 5 2 12 TOP 2x6 DRY SPF No.2 T-BRACE AT 2-9, 4-9 THIS DESIGN COMPLIES WITH:
BOTTOM CHORDS : (0.144"X3") NAILS - PART 9 OF BCBC 2018 , ABC 2019
11- 8 2 5 SIDE(651.8) FASTEN T AND I-BRACES TO NARROW EDGE OF WEB WITH ONE ROW PER PLY OF 3" - PART 9 OF OBC 2012 (2019 AMENDMENT)
8- 6 2 5 SIDE(651.8) COMMON WIRE NAILS @ 6" O.C. WITH 3" MINIMUM END DISTANCE. BRACE MUST COVER 90% - CSA 086-14
WEBS : (0.144"X3") NAILS OF WEB LENGTH. - TPIC 2014
2x3 1 6
END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
STAGGER NAILS BY HALF THE SURFACE SPACING IN THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
ADJACENT PLIES. LIVE LOAD
LOADING
TOP - COMPONENTS ARE LOADED FROM THE TOP AND TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.68")
MUST BE PLACED ON TOP EDGE OF ALL PLIES FOR CALCULATED VERT. DEFL.(LL) = L/ 999 (0.11")
THE LOAD TO BE TRANSFERRED TO EACH PLY. CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.68")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.20")
SIDE - PLF SHOWN IS THE EQUIVALENT UDL APPLIED MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
TO ONE SIDE THAT THE CORRESPONDING NAILING (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.48/1.00 (1-2:1) , BC=0.85/1.00 (9-10:1) ,
PATTERN SHALL BE CAPABLE OF TRANSFERING. FR-TO FROM TO LENGTH FR-TO WB=0.75/1.00 (3-9:1) , SSI=0.62/1.00 (10-11:3)
REMAINING PLF MUST BE APPLIED ON THE OPPOSITE 1- 2 -10998 / 0 -109.0 -109.0 0.48 (1) 3.47 10- 2 0 / 4312 0.32 (3)
SIDE OR ON THE TOP. 2- 3 -7815 / 0 -109.0 -109.0 0.29 (1) 4.13 2- 9 -3660 / 0 0.43 (2) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
3- 4 -7814 / 0 -109.0 -109.0 0.27 (1) 4.13 9- 3 0 / 9942 0.75 (1) COMP=1.10 SHEAR=1.10 TENS= 1.10
4- 5 -10638 / 0 -109.0 -109.0 0.44 (1) 3.54 9- 4 -3336 / 0 0.39 (3)
PLATES (table is in inches) 11- 1 -9057 / 0 0.0 0.0 0.20 (1) 6.07 7- 4 0 / 3897 0.29 (2) COMPANION LIVE LOAD FACTOR = 1.00
JT TYPE PLATES W LEN Y X 6- 5 -9098 / 0 0.0 0.0 0.20 (1) 6.06 1-10 0 / 8344 0.63 (1)
1 TMVW-t MT20 5.0 8.0 1.50 3.25 7- 5 0 / 8136 0.61 (1) AUTOSOLVE HEELS OFF
2 TMWW-t MT20 4.0 6.0 2.00 2.00 11-10 0/0 -996.2 -996.2 0.53 (3) 10.00
3 TTW+p MT20 4.0 8.0 Edge 10- 9 0 / 8216 -996.2 -996.2 0.85 (1) 10.00 TRUSS PLATE MANUFACTURER IS NOT
4 TMWW-t MT20 4.0 6.0 2.00 2.25 9- 8 0 / 7947 -996.2 -996.2 0.82 (1) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
5 TMVW-t MT20 5.0 8.0 1.50 3.25 8- 7 0 / 7947 -996.2 -996.2 0.82 (1) 10.00 TRUSS MANUFACTURING PLANT .
6 BMV1+p MT20 3.0 4.0 2.25 1.50 7- 6 0/0 -996.2 -996.2 0.51 (2) 10.00
7 BMWW-t MT20 7.0 8.0 4.25 3.25 NAIL VALUES
8 BS-t MT20 4.0 6.0 PLATE GRIP(DRY) SHEAR SECTION
9 BMWWW+t MT20 6.0 10.0 TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING (PSI) (PLI) (PLI)
10 BMWW+t MT20 6.0 8.0 4.25 2.00 AS PER NBCC 4.1.6.2.(8) MAX MIN MAX MIN MAX MIN
11 BMV1+t MT20 6.0 8.0 5.50 MT20 650 371 1747 788 1987 1873

Edge - INDICATES REFERENCE CORNER OF PLATE PLATE PLACEMENT TOL. = 0.250 inches
TOUCHES EDGE OF CHORD.
PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.87 (10) (INPUT = 0.90 )


JSI METAL= 0.82 (10) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A DGF 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:38 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Oko1HNhj3dlerXRnNGkOYSiG82el0JlkdNHI?9zRBRF
10-8 5-2-12 5-0-4 5-0-4 5-2-12 10-8
4x6 Scale = 1:98.5

10.75 12
4x4 3x4
3 5
ST3 ST3

10-6-7
T1 T1
ST5 ST5
W1

4x4 ST2 ST4 ST6 W2 4x4


2 ST1 W3 W3
W2 6
1

1-4-4

1-4-4
W5 W5 7
W4 B1 W4
10
13 12 11 9 8
3x4 28 3x6
3x6
10-8 20-6-0 3x4 10-8
5-2-12 5-0-4 5-0-4 5-2-12
20-6-0

TOTAL WEIGHT = 120 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 7 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
13 - 2 2x3 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 6 2x3 DRY No.2 SPF 13 498 0 508 0 0 9-5-8 1-8 BOT CH. LL = 0.0 PSF
13 - 10 2x4 DRY No.2 SPF 12 1046 0 1046 0 0 9-5-8 1-8 DL = 7.4 PSF
10 - 8 2x4 DRY No.2 SPF 8 1030 0 1030 0 0 5-8 1-8 TOTAL LOAD = 44.7 PSF
28 252 0 252 0 0 9-5-8 1-8
ALL WEBS 2x3 DRY No.2 SPF SPACING = 24.0 IN. C/C
ALL GABLE WEBS
2x3 DRY No.2 SPF UNFACTORED REACTIONS THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. 1ST LCASE MAX./MIN. COMPONENT REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL NBCC 2015
GABLE STUDS SPACED AT 2-0-0 OC. 13 345 274 / -7 0/0 0/0 0/0 78 / 0 0/0
12 737 501 / 0 0/0 0/0 0/0 236 / 0 0/0 THIS DESIGN COMPLIES WITH:
8 719 521 / 0 0/0 0/0 0/0 198 / 0 0/0 - PART 9 OF BCBC 2018 , ABC 2019
28 178 117 / 0 0/0 0/0 0/0 61 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
PLATES (table is in inches) BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 13, 12, 8, 28 - TPIC 2014
JT TYPE PLATES W LEN Y X
2 TMVW-t MT20 4.0 4.0 2.00 1.25 BRACING (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
3 TMWW-t MT20 4.0 4.0 2.00 1.25 TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 5.99 FT. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
4 TTW+p MT20 4.0 6.0 Edge MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. LIVE LOAD
5 TMWW-t MT20 3.0 4.0 1.50 1.25
6 TMVW-t MT20 4.0 4.0 2.00 1.25 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(LL)= L/360 (0.37")
8 BMV1+p MT20 2.0 4.0 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.03")
9 BMWW-t MT20 3.0 4.0 1.50 1.75 LOADING ALLOWABLE DEFL.(TL)= L/360 (0.37")
10 BS-t MT20 3.0 6.0 TOTAL LOAD CASES: (8) CALCULATED VERT. DEFL.(TL) = L/ 999 (0.05")
11 BMWWW-t MT20 3.0 6.0
12 BMWW1+t MT20 3.0 4.0 1.50 1.50 CHORDS WEBS CSI: TC=0.53/1.00 (5-6:1) , BC=0.18/1.00 (9-11:1) ,
13 BMV1+p MT20 2.0 4.0 MAX. FACTORED FACTORED MAX. FACTORED WB=0.62/1.00 (5-11:3) , SSI=0.21/1.00 (2-3:1)
14 NP+w MT20 2.0 4.0 1.75 1.00 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
14 NP+w MT20 2.0 4.0 FR-TO FROM TO LENGTH FR-TO COMP=1.10 SHEAR=1.10 TENS= 1.10
17 NP+w MT20 2.0 4.0 1.75 1.00 1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 11- 4 0 / 98 0.02 (3)
2- 3 -133 / 6 -109.0 -109.0 0.49 (2) 6.25 11- 5 -533 / 0 0.62 (3) COMPANION LIVE LOAD FACTOR = 1.00
Edge - INDICATES REFERENCE CORNER OF PLATE 3- 4 -406 / 0 -109.0 -109.0 0.51 (1) 6.25 9- 5 0 / 96 0.03 (8)
TOUCHES EDGE OF CHORD. 4- 5 -405 / 0 -109.0 -109.0 0.50 (1) 6.25 3-11 0 / 277 0.06 (3)
5- 6 -780 / 0 -109.0 -109.0 0.53 (1) 5.99 12- 3 -993 / 0 0.56 (1) TRUSS PLATE MANUFACTURER IS NOT
6- 7 0 / 35 -109.0 -109.0 0.08 (1) 10.00 2-12 0 / 136 0.03 (2) RESPONSIBLE FOR QUALITY CONTROL IN THE
13- 2 -468 / 0 0.0 0.0 0.07 (2) 7.81 9- 6 0 / 626 0.14 (1) TRUSS MANUFACTURING PLANT .
8- 6 -993 / 0 0.0 0.0 0.14 (1) 6.90
NAIL VALUES
13-12 0/0 -18.5 -18.5 0.11 (8) 10.00 PLATE GRIP(DRY) SHEAR SECTION
12-28 0 / 133 -18.5 -18.5 0.16 (1) 10.00 (PSI) (PLI) (PLI)
28-11 0 / 133 -18.5 -18.5 0.16 (1) 10.00 MAX MIN MAX MIN MAX MIN
11-10 0 / 615 -18.5 -18.5 0.18 (1) 10.00 MT20 650 371 1747 788 1987 1873
10- 9 0 / 615 -18.5 -18.5 0.18 (1) 10.00
9- 8 0/0 -18.5 -18.5 0.13 (8) 10.00 PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) JSI GRIP= 0.90 (9) (INPUT = 0.90 )
JSI METAL= 0.36 (6) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A E 2 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:39 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-swMPUjiLqxtVSh0zxzGd4fFS2StllnHus11sXbzRBRE
10-8 5-1-4 4-10-12 4-10-12 4-10-10
4x6 Scale: 1/8"=1'

10.75 12
4x4 4x4
3 T2 5

10-3-12
T1
W1
O1
W4 2x4
2x4 6
2 W3 W2 W2

1-6-10
1 W6

1-4-4
W5
B1 B2
8
10 9 7
3x6
4x6 4x6 4x4
10-8 19-9-6
10-0-0 9-9-6
19-9-6

TOTAL WEIGHT = 2 X 88 = 176 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
10 - 2 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
7 - 6 2x4 DRY No.2 SPF 10 1367 0 1367 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
10 - 8 2x4 DRY No.2 SPF 7 1261 0 1261 0 0 2-14 1-8 DL = 7.4 PSF
8 - 7 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. 10 957 681 / 0 0/0 0/0 0/0 277 / 0 0/0 SMALL BUILDING REQUIREMENTS OF PART 9,
7 885 620 / 0 0/0 0/0 0/0 265 / 0 0/0 NBCC 2015

BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 10, 7 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , ABC 2019
PLATES (table is in inches) BRACING - PART 9 OF OBC 2012 (2019 AMENDMENT)
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 5.99 FT. - CSA 086-14
2 TMV+p MT20 2.0 4.0 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. - TPIC 2014
3 TMWW-t MT20 4.0 4.0 1.75 1.50
4 TTW+p MT20 4.0 6.0 Edge ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
5 TMWW-t MT20 4.0 4.0 1.75 1.50 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
6 TMV+p MT20 2.0 4.0 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 5-7. DBS = 20-0-0 . CBF = 166 LIVE LOAD
7 BMVW1-t MT20 4.0 4.0 2.00 1.75 LBS.
8 BS-t MT20 3.0 6.0 2x4 DRY SPF No.2 T-BRACE AT 3-10 ALLOWABLE DEFL.(LL)= L/360 (0.66")
9 BMWWW-t MT20 4.0 6.0 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.03")
10 BMVW1-t MT20 4.0 6.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). ALLOWABLE DEFL.(TL)= L/360 (0.66")
FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, CALCULATED VERT. DEFL.(TL) = L/ 999 (0.23")
Edge - INDICATES REFERENCE CORNER OF PLATE 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12.
TOUCHES EDGE OF CHORD. CSI: TC=0.46/1.00 (2-3:2) , BC=0.58/1.00 (9-10:8) ,
FASTEN T AND I-BRACES TO NARROW EDGE OF WEB WITH ONE ROW PER PLY OF 3" WB=0.53/1.00 (3-10:1) , SSI=0.20/1.00 (3-4:2)
COMMON WIRE NAILS @ 6" O.C. WITH 3" MINIMUM END DISTANCE. BRACE MUST COVER 90%
OF WEB LENGTH. DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
COMP=1.10 SHEAR=1.10 TENS= 1.10
END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN
THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW COMPANION LIVE LOAD FACTOR = 1.00

LOADING
TOTAL LOAD CASES: (8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
CHORDS WEBS TRUSS MANUFACTURING PLANT .
MAX. FACTORED FACTORED MAX. FACTORED
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX NAIL VALUES
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) PLATE GRIP(DRY) SHEAR SECTION
FR-TO FROM TO LENGTH FR-TO (PSI) (PLI) (PLI)
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 3- 9 -399 / 0 0.43 (2) MAX MIN MAX MIN MAX MIN
2- 3 0 / 44 -109.0 -109.0 0.46 (2) 10.00 9- 4 0 / 738 0.17 (1) MT20 650 371 1747 788 1987 1873
3- 4 -912 / 0 -109.0 -109.0 0.36 (1) 5.99 9- 5 -367 / 12 0.40 (3)
4- 5 -910 / 0 -109.0 -109.0 0.35 (1) 6.01 10- 3 -1331 / 0 0.53 (1) PLATE PLACEMENT TOL. = 0.250 inches
5- 6 0 / 44 -109.0 -109.0 0.44 (3) 10.00 5- 7 -1324 / 0 0.46 (1)
10- 2 -311 / 0 0.0 0.0 0.03 (1) 7.81 PLATE ROTATION TOL. = 5.0 Deg.
7- 6 -193 / 0 0.0 0.0 0.02 (1) 7.81
JSI GRIP= 0.88 (7) (INPUT = 0.90 )
10- 9 0 / 896 -18.5 -18.5 0.58 (8) 10.00 JSI METAL= 0.45 (3) (INPUT = 1.00 )
9- 8 0 / 869 -18.5 -18.5 0.58 (8) 10.00
8- 7 0 / 869 -18.5 -18.5 0.58 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A EA 8 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:39 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-swMPUjiLqxtVSh0zxzGd4fFTLSu_loWus11sXbzRBRE
4-10-10 4-10-12 4-10-12 4-10-10
4x6 Scale = 1:91.7

10.75 12

4x4 4x4
2 T1 T1 4

10-3-12
W1
W3 W3 2x4
2x4
W2 W2 5
1

1-6-10

1-6-10
W4 W4
B1 B2
7
9 8 6
4x4 4x6 3x6 4x4
19-6-12
9-9-6 9-9-6
19-6-12

TOTAL WEIGHT = 8 X 86 = 688 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 3 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
3 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
9 - 1 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
6 - 5 2x4 DRY No.2 SPF 9 1247 0 1247 0 0 3-6 1-8 BOT CH. LL = 0.0 PSF
9 - 7 2x4 DRY No.2 SPF 6 1247 0 1247 0 0 3-6 1-8 DL = 7.4 PSF
7 - 6 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. 9 875 613 / 0 0/0 0/0 0/0 262 / 0 0/0 SMALL BUILDING REQUIREMENTS OF PART 9,
6 875 613 / 0 0/0 0/0 0/0 262 / 0 0/0 NBCC 2015

BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 9, 6 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , ABC 2019
PLATES (table is in inches) BRACING - PART 9 OF OBC 2012 (2019 AMENDMENT)
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.05 FT. - CSA 086-14
1 TMV+p MT20 2.0 4.0 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. - TPIC 2014
2 TMWW-t MT20 4.0 4.0 1.75 1.50
3 TTW+p MT20 4.0 6.0 Edge ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
4 TMWW-t MT20 4.0 4.0 1.75 1.50 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
5 TMV+p MT20 2.0 4.0 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 2-9, 4-6. DBS = 20-0-0 . CBF = 163 LIVE LOAD
6 BMVW1-t MT20 4.0 4.0 2.00 1.75 LBS.
7 BS-t MT20 3.0 6.0 ALLOWABLE DEFL.(LL)= L/360 (0.65")
8 BMWWW-t MT20 4.0 6.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). CALCULATED VERT. DEFL.(LL) = L/ 999 (0.03")
9 BMVW1-t MT20 4.0 4.0 2.00 1.75 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, ALLOWABLE DEFL.(TL)= L/360 (0.65")
2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.21")
Edge - INDICATES REFERENCE CORNER OF PLATE
TOUCHES EDGE OF CHORD. END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN CSI: TC=0.44/1.00 (4-5:3) , BC=0.57/1.00 (8-9:8) ,
THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW WB=0.46/1.00 (4-6:1) , SSI=0.20/1.00 (3-4:3)

LOADING DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10


TOTAL LOAD CASES: (8) COMP=1.10 SHEAR=1.10 TENS= 1.10

CHORDS WEBS COMPANION LIVE LOAD FACTOR = 1.00


MAX. FACTORED FACTORED MAX. FACTORED
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) TRUSS PLATE MANUFACTURER IS NOT
FR-TO FROM TO LENGTH FR-TO RESPONSIBLE FOR QUALITY CONTROL IN THE
1- 2 0 / 44 -109.0 -109.0 0.44 (2) 10.00 8- 3 0 / 710 0.16 (1) TRUSS MANUFACTURING PLANT .
2- 3 -891 / 0 -109.0 -109.0 0.35 (1) 6.05 8- 4 -369 / 10 0.40 (3)
3- 4 -891 / 0 -109.0 -109.0 0.35 (1) 6.05 2- 8 -369 / 10 0.40 (2) NAIL VALUES
4- 5 0 / 44 -109.0 -109.0 0.44 (3) 10.00 9- 2 -1305 / 0 0.46 (1) PLATE GRIP(DRY) SHEAR SECTION
9- 1 -193 / 0 0.0 0.0 0.02 (1) 7.81 4- 6 -1305 / 0 0.46 (1) (PSI) (PLI) (PLI)
6- 5 -193 / 0 0.0 0.0 0.02 (1) 7.81 MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873
9- 8 0 / 856 -18.5 -18.5 0.57 (8) 10.00
8- 7 0 / 856 -18.5 -18.5 0.57 (8) 10.00 PLATE PLACEMENT TOL. = 0.250 inches
7- 6 0 / 856 -18.5 -18.5 0.57 (8) 10.00
PLATE ROTATION TOL. = 5.0 Deg.

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING JSI GRIP= 0.87 (9) (INPUT = 0.90 )
AS PER NBCC 4.1.6.2.(8) JSI METAL= 0.44 (4) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A EG1 2 3 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:40 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-K6wni3izbE?M4qbAUhnsdtoepsAzUBo14hmP42zRBRD
4-11-15 4-9-7 4-9-7 4-11-15
4x8 Scale = 1:91.7

10.75 12
4x6 4x6
2 T1 4
T1

10-3-12
O1 W1
O2
5x8 6x8
W3 W2 W2 W3 5
1

1-6-10

1-6-10
W6 W7
W4 B1 B2 W5

8
11 10 9 7 6
4x8 7x8 6x8 6x6 6x8 4x8
19-6-12
4-11-15 4-9-7 4-9-7 4-11-15
19-6-12

TOTAL WEIGHT = 6 X 104 = 623 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 3 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
3 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
11 - 1 2x6 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
6 - 5 2x4 DRY No.2 SPF 11 10810 0 10810 0 0 3-6 3-6 BOT CH. LL = 0.0 PSF
11 - 8 2x6 DRY No.2 SPF 6 10810 0 10810 0 0 3-6 3-6 DL = 7.4 PSF
8 - 6 2x6 DRY No.2 SPF TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL GIRDER TYPE: CStdGirder
DRY: SEASONED LUMBER. 11 7586 5313 / 0 0/0 0/0 0/0 2273 / 0 0/0 START DISTANCE = 0-0
6 7586 5313 / 0 0/0 0/0 0/0 2273 / 0 0/0 START SPAN CARRIED = 32-11-8
DESIGN CONSISTS OF 3 TRUSSES BUILT END DISTANCE = 19-6-12
SEPARATELY THEN FASTENED TOGETHER AS BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 11, 6 END SPAN CARRIED = 32-11-8
FOLLOWS: BEARING SIZE FACTOR = 1.15 AT JNT(S) 11, 6 ( BASED ON SUPPORT DEPTH = 1-8 ) END WALL WIDTH = 3-6
APPLIED TO FRONT SIDE OF BOTTOM CHORD.
CHORDS #ROWS SURFACE LOAD(PLF) BRACING - ADDT'L LOADS BASED ON 55 % OF GSL.
SPACING (IN) TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.63 FT.
TOP CHORDS : (0.144"X3") NAILS MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
1- 3 1 12 TOP SMALL BUILDING REQUIREMENTS OF PART 9,
3- 5 1 12 TOP ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015
6- 5 1 12 TOP
11- 1 2 12 TOP 2x6 DRY SPF No.2 T-BRACE AT 4-9, 2-9 THIS DESIGN COMPLIES WITH:
BOTTOM CHORDS : (0.144"X3") NAILS - PART 9 OF BCBC 2018 , ABC 2019
11- 8 2 5 SIDE(651.8) FASTEN T AND I-BRACES TO NARROW EDGE OF WEB WITH ONE ROW PER PLY OF 3" - PART 9 OF OBC 2012 (2019 AMENDMENT)
8- 6 2 5 SIDE(651.8) COMMON WIRE NAILS @ 6" O.C. WITH 3" MINIMUM END DISTANCE. BRACE MUST COVER 90% - CSA 086-14
WEBS : (0.144"X3") NAILS OF WEB LENGTH. - TPIC 2014
2x3 1 6
END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
STAGGER NAILS BY HALF THE SURFACE SPACING IN THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
ADJACENT PLIES. LIVE LOAD
LOADING
TOP - COMPONENTS ARE LOADED FROM THE TOP AND TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.65")
MUST BE PLACED ON TOP EDGE OF ALL PLIES FOR CALCULATED VERT. DEFL.(LL) = L/ 999 (0.10")
THE LOAD TO BE TRANSFERRED TO EACH PLY. CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.65")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.17")
SIDE - PLF SHOWN IS THE EQUIVALENT UDL APPLIED MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
TO ONE SIDE THAT THE CORRESPONDING NAILING (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.39/1.00 (1-2:1) , BC=0.78/1.00 (9-10:1) ,
PATTERN SHALL BE CAPABLE OF TRANSFERING. FR-TO FROM TO LENGTH FR-TO WB=0.71/1.00 (3-9:1) , SSI=0.59/1.00 (10-11:3)
REMAINING PLF MUST BE APPLIED ON THE OPPOSITE 1- 2 -10177 / 0 -109.0 -109.0 0.39 (1) 3.63 9- 3 0 / 9453 0.71 (1)
SIDE OR ON THE TOP. 2- 3 -7435 / 0 -109.0 -109.0 0.24 (1) 4.24 9- 4 -3247 / 0 0.36 (3) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
3- 4 -7435 / 0 -109.0 -109.0 0.24 (1) 4.24 7- 4 0 / 3796 0.28 (2) COMP=1.10 SHEAR=1.10 TENS= 1.10
4- 5 -10176 / 0 -109.0 -109.0 0.39 (1) 3.63 2- 9 -3249 / 0 0.36 (2)
PLATES (table is in inches) 11- 1 -8751 / 0 0.0 0.0 0.19 (1) 6.15 10- 2 0 / 3798 0.28 (3) COMPANION LIVE LOAD FACTOR = 1.00
JT TYPE PLATES W LEN Y X 6- 5 -8749 / 0 0.0 0.0 0.30 (1) 5.05 1-10 0 / 7793 0.58 (1)
1 TMVW-t MT20 5.0 8.0 1.75 3.25 7- 5 0 / 7792 0.58 (1) AUTOSOLVE HEELS OFF
2 TMWW-t MT20 4.0 6.0 2.00 2.50 11-10 0/0 -996.2 -996.2 0.48 (3) 10.00
3 TTW+p MT20 4.0 8.0 Edge 10- 9 0 / 7602 -996.2 -996.2 0.78 (1) 10.00 TRUSS PLATE MANUFACTURER IS NOT
4 TMWW-t MT20 4.0 6.0 2.00 2.50 9- 8 0 / 7601 -996.2 -996.2 0.77 (1) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
5 TMVW+p MT20 6.0 8.0 2.75 2.00 8- 7 0 / 7601 -996.2 -996.2 0.77 (1) 10.00 TRUSS MANUFACTURING PLANT .
6 BMV1+t MT20 4.0 8.0 Edge 0.50 7- 6 0/0 -996.2 -996.2 0.48 (2) 10.00
7 BMWW+t MT20 6.0 8.0 4.25 2.25 NAIL VALUES
8 BS-t MT20 6.0 6.0 PLATE GRIP(DRY) SHEAR SECTION
9 BMWWW+t MT20 6.0 8.0 4.25 3.00 TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING (PSI) (PLI) (PLI)
10 BMWW-t MT20 7.0 8.0 4.25 3.50 AS PER NBCC 4.1.6.2.(8) MAX MIN MAX MIN MAX MIN
11 BMV1+t MT20 4.0 8.0 5.50 MT20 650 371 1747 788 1987 1873

Edge - INDICATES REFERENCE CORNER OF PLATE PLATE PLACEMENT TOL. = 0.250 inches
TOUCHES EDGE OF CHORD.
PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.90 (9) (INPUT = 0.90 )


JSI METAL= 0.95 (5) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A EGF 2 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:40 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-K6wni3izbE?M4qbAUhnsdtodFsFgUFE14hmP42zRBRD
10-8 5-1-4 4-10-12 4-10-12 5-1-4 10-8
4x6 Scale: 1/8"=1'

10.75 12
4x4 4x4
3 5

10-3-12
ST3 ST3
T1 T1
O1 ST5 ST5
W1 O1
ST2
W3 ST6 W2
2 ST4 W3
W2 6
1 W4 ST1

1-4-4

1-4-4
W4 7
B1 B2

26 10 9
11 8
3x6
4x6 3x8 4x6
10-8 20-0-0 10-8
10-0-0 10-0-0
20-0-0

TOTAL WEIGHT = 2 X 111 = 223 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 7 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
11 - 2 2x3 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 6 2x3 DRY No.2 SPF 11 1254 0 1254 0 0 8-11-8 1-8 BOT CH. LL = 0.0 PSF
11 - 9 2x4 DRY No.2 SPF 8 1278 0 1278 0 0 5-8 1-8 DL = 7.4 PSF
9 - 8 2x4 DRY No.2 SPF 26 230 0 230 0 0 8-11-8 1-8 TOTAL LOAD = 44.7 PSF

ALL WEBS 2x3 DRY No.2 SPF SPACING = 24.0 IN. C/C
ALL GABLE WEBS UNFACTORED REACTIONS
2x3 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL SMALL BUILDING REQUIREMENTS OF PART 9,
11 875 642 / 0 0/0 0/0 0/0 233 / 0 0/0 NBCC 2015
GABLE STUDS SPACED AT 2-0-0 OC. 8 892 650 / 0 0/0 0/0 0/0 242 / 0 0/0
26 167 83 / 0 0/0 0/0 0/0 84 / 0 0/0 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , ABC 2019
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 11, 8, 26 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
PLATES (table is in inches) BRACING - TPIC 2014
JT TYPE PLATES W LEN Y X TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.07 FT.
2 TMV+p MT20 2.0 4.0 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
3 TMWW-t MT20 4.0 4.0 2.00 1.50 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
4 TTW+p MT20 4.0 6.0 Edge ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LIVE LOAD
5 TMWW-t MT20 4.0 4.0 2.00 1.50
6 TMV+p MT20 2.0 4.0 2x4 DRY SPF No.2 T-BRACE AT 3-11, 5-8 ALLOWABLE DEFL.(LL)= L/360 (0.37")
8 BMVW1-t MT20 4.0 6.0 Edge CALCULATED VERT. DEFL.(LL) = L/ 999 (0.08")
9 BS-t MT20 3.0 6.0 FASTEN T AND I-BRACES TO NARROW EDGE OF WEB WITH ONE ROW PER PLY OF 3" ALLOWABLE DEFL.(TL)= L/360 (0.37")
10 BMWWW-t MT20 3.0 8.0 COMMON WIRE NAILS @ 6" O.C. WITH 3" MINIMUM END DISTANCE. BRACE MUST COVER 90% CALCULATED VERT. DEFL.(TL) = L/ 385 (0.34")
11 BMVW1-t MT20 4.0 6.0 Edge OF WEB LENGTH.
12 NP+w MT20 2.0 4.0 1.75 1.00 CSI: TC=0.49/1.00 (4-5:1) , BC=0.48/1.00 (10-26:8) ,
12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN WB=0.49/1.00 (5-8:1) , SSI=0.20/1.00 (4-5:3)
12 NP+w MT20 2.0 4.0 THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW
15 NP+w MT20 2.0 4.0 1.75 1.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
LOADING COMP=1.10 SHEAR=1.10 TENS= 1.10
Edge - INDICATES REFERENCE CORNER OF PLATE TOTAL LOAD CASES: (8)
TOUCHES EDGE OF CHORD. COMPANION LIVE LOAD FACTOR = 1.00
CHORDS WEBS
MAX. FACTORED FACTORED MAX. FACTORED
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX TRUSS PLATE MANUFACTURER IS NOT
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) RESPONSIBLE FOR QUALITY CONTROL IN THE
FR-TO FROM TO LENGTH FR-TO TRUSS MANUFACTURING PLANT .
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 10- 4 0 / 564 0.13 (1)
2- 3 0 / 44 -109.0 -109.0 0.46 (2) 10.00 10- 5 -410 / 0 0.45 (3) NAIL VALUES
3- 4 -779 / 0 -109.0 -109.0 0.49 (1) 6.07 3-10 -410 / 0 0.45 (2) PLATE GRIP(DRY) SHEAR SECTION
4- 5 -779 / 0 -109.0 -109.0 0.49 (1) 6.07 11- 3 -1199 / 0 0.49 (1) (PSI) (PLI) (PLI)
5- 6 0 / 44 -109.0 -109.0 0.46 (3) 10.00 5- 8 -1199 / 0 0.49 (1) MAX MIN MAX MIN MAX MIN
6- 7 0 / 35 -109.0 -109.0 0.08 (1) 10.00 MT20 650 371 1747 788 1987 1873
11- 2 -311 / 0 0.0 0.0 0.04 (1) 7.81
8- 6 -311 / 0 0.0 0.0 0.04 (1) 7.81 PLATE PLACEMENT TOL. = 0.250 inches

11-26 0 / 806 -18.5 -18.5 0.46 (8) 10.00 PLATE ROTATION TOL. = 5.0 Deg.
26-10 0 / 806 -18.5 -18.5 0.48 (8) 10.00
10- 9 0 / 806 -18.5 -18.5 0.48 (8) 10.00 JSI GRIP= 0.84 (5) (INPUT = 0.90 )
9- 8 0 / 806 -18.5 -18.5 0.48 (8) 10.00 JSI METAL= 0.40 (3) (INPUT = 1.00 )

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A FG1 2 3 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:52 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Vmg?AbiHzduW7oJInBQrtDf4biJI?0IMjki0Pxz606j
3-9-9 3-8-5 3-9-9
2x4 3x4 Scale = 1:20.0
4x10 4x10
1 2 3 4
2-12 T1 2-12

W1 W1
1-11-4

W2 W3 W4 W3 W2

3-12

3-12
B1
4-0 2-0

8 7 6 6x8
Provide a 20" long 2x8 vertical scab at
6x10
joint 5, two sides, nailed to chord with 4
5
2x4 rows of 3" common nails @ 3" o/c, (30
2x4
nails min) 1-6 bearing.
11-3-6
3-9-9 3-8-5 3-9-9
11-3-6

TOTAL WEIGHT = 6 X 50 = 301 lb


***BEARING UNDERSIZED: 5***
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
8 - 1 2x6 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 4 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x6 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 5 2x6 DRY No.2 SPF 8 7447 0 7447 0 0 5-8 2-11 BOT CH. LL = 0.0 PSF
5 7447 0 7447 0 0 1-6 2-11 DL = 7.4 PSF
ALL WEBS 2x3 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
EXCEPT
1 - 7 2x4 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
6 - 4 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
DRY: SEASONED LUMBER. 8 5226 3660 / 0 0/0 0/0 0/0 1566 / 0 0/0 LOADING IN FLAT SECTION BASED ON A SLOPE
5 5226 3660 / 0 0/0 0/0 0/0 1566 / 0 0/0 OF 6.00/12
DESIGN CONSISTS OF 3 TRUSSES BUILT
SEPARATELY THEN FASTENED TOGETHER AS BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 8, 5 GIRDER TYPE: CStdGirder
FOLLOWS: START DISTANCE = 0-0
BRACING START SPAN CARRIED = 39-6-8
CHORDS #ROWS SURFACE LOAD(PLF) TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.23 FT. END DISTANCE = 11-3-6
SPACING (IN) MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. END SPAN CARRIED = 39-6-8
TOP CHORDS : (0.144"X3") NAILS END WALL WIDTH = 1-6
8- 1 2 12 TOP ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. APPLIED TO FRONT SIDE OF BOTTOM CHORD.
4- 5 2 12 TOP - ADDT'L LOADS BASED ON 55 % OF GSL.
1- 4 1 12 TOP LOADING
BOTTOM CHORDS : (0.144"X3") NAILS TOTAL LOAD CASES: (8) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
8- 5 3 6 SIDE(795.2) SMALL BUILDING REQUIREMENTS OF PART 9,
WEBS : (0.144"X3") NAILS CHORDS WEBS NBCC 2015
2x3 1 6 MAX. FACTORED FACTORED MAX. FACTORED
2x4 1 6 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX THIS DESIGN COMPLIES WITH:
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) - PART 9 OF BCBC 2018 , NBC-2019AE
STAGGER NAILS BY HALF THE SURFACE SPACING IN FR-TO FROM TO LENGTH FR-TO - PART 9 OF OBC 2012 (2019 AMENDMENT)
ADJACENT PLIES. 8- 1 -5359 / 0 0.0 0.0 0.12 (1) 7.45 1- 7 0 / 13492 0.72 (1) - CSA 086-14
1- 2 -12478 / 0 -109.0 -109.0 0.32 (1) 3.24 7- 2 -378 / 0 0.02 (1) - TPIC 2014
TOP - COMPONENTS ARE LOADED FROM THE TOP AND 2- 3 -12478 / 0 -109.0 -109.0 0.32 (1) 3.24 7- 3 -121 / 0 0.01 (1)
MUST BE PLACED ON TOP EDGE OF ALL PLIES FOR 3- 4 -12589 / 0 -109.0 -109.0 0.32 (1) 3.23 6- 3 -360 / 0 0.02 (1) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
THE LOAD TO BE TRANSFERRED TO EACH PLY. 5- 4 -5395 / 0 0.0 0.0 0.12 (1) 7.43 6- 4 0 / 13612 0.73 (1) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
SIDE - PLF SHOWN IS THE EQUIVALENT UDL APPLIED 8- 7 0/0 -1211.3-1211.3 0.40 (1) 10.00
TO ONE SIDE THAT THE CORRESPONDING NAILING 7- 6 0 / 12589 -1211.3-1211.3 0.76 (1) 10.00 ALLOWABLE DEFL.(LL)= L/360 (0.38")
PATTERN SHALL BE CAPABLE OF TRANSFERING. 6- 5 0/0 -1211.3-1211.3 0.39 (1) 10.00 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.11")
REMAINING PLF MUST BE APPLIED ON THE OPPOSITE ALLOWABLE DEFL.(TL)= L/360 (0.38")
SIDE OR ON THE TOP. CALCULATED VERT. DEFL.(TL) = L/ 686 (0.20")
TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) CSI: TC=0.32/1.00 (2-3:1) , BC=0.76/1.00 (6-7:1) ,
PLATES (table is in inches) WB=0.73/1.00 (4-6:1) , SSI=0.51/1.00 (5-6:1)
JT TYPE PLATES W LEN Y X
1 TMVW-t MT20 4.0 10.0 2.00 2.75 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2 TMW+w MT20 2.0 4.0 COMP=1.10 SHEAR=1.10 TENS= 1.10
3 TMWW-t MT20 3.0 4.0
4 TMVW-t MT20 4.0 10.0 2.00 2.75 COMPANION LIVE LOAD FACTOR = 1.00
5 BMV1+p MT20 2.0 4.0
6 BMWW-t MT20 6.0 8.0 3.75 2.00
7 BMWWW-t MT20 6.0 10.0 3.75 4.00 TRUSS PLATE MANUFACTURER IS NOT
8 BMV1+p MT20 2.0 4.0 RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.90 (5) (INPUT = 0.90 )


JSI METAL= 0.72 (6) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A G 5 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:52 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Vmg?AbiHzduW7oJInBQrtDfxBiKO?_oMjki0Pxz606j
10-8 6-10-11 6-8-3 6-8-3 6-8-3 6-8-3 6-5-3
4x6 Scale = 1:90.6
5.75 12
6

3x4 T2 T2 3x4
3x6
5 7 3x6
2 0-1
0-1 2 8

1-8
1-8
4
10-7-11

3x4 3x4
3 W2 W1 W2 9
2 1-1
T1 1-1 2
T3
W3 W3 5x8

W5 W4 W4 W5 3-0 10
12 2-8

1-1-14
W8
11-4

W9
B1 B2 B1

2
2-12

W6 W7

1-1
1-8 1-12 0-8
16 14
19 18 17 15 13 12 11
8x10 6x6 4x4 4x6 6x6 4x6 3x4 6x6 4x6
10-8 40-0-8
6-10-11 6-8-3 6-8-3 6-8-3 6-8-3 6-5-3
40-0-8

TOTAL WEIGHT = 5 X 162 = 811 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY 2100F 1.8E SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 8 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
8 - 10 2x4 DRY No.2 SPF 19 2655 0 2655 0 0 5-8 5-2 BOT CH. LL = 0.0 PSF
19 - 2 2x4 DRY No.2 SPF 11 2552 0 2552 0 0 MECHANICAL DL = 7.4 PSF
11 - 10 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
19 - 16 2x4 DRY No.2 SPF A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 11. MINIMUM
16 - 14 2x4 DRY No.2 SPF BEARING LENGTH AT JOINT 11 = 3-8. SPACING = 24.0 IN. C/C
14 - 11 2x4 DRY No.2 SPF
THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
ALL WEBS 2x3 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
EXCEPT UNFACTORED REACTIONS NBCC 2015
1ST LCASE MAX./MIN. COMPONENT REACTIONS
DRY: SEASONED LUMBER. JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS DESIGN COMPLIES WITH:
19 1861 1313 / 0 0/0 0/0 0/0 548 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
11 1791 1254 / 0 0/0 0/0 0/0 537 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 19 - TPIC 2014
PLATES (table is in inches)
JT TYPE PLATES W LEN Y X BRACING (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
2 TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 2.73 FT. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMWW-t MT20 3.0 4.0 1.50 1.75 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. LIVE LOAD
4 TS-t MT20 3.0 6.0
5 TMWW+t MT20 3.0 4.0 1.50 0.75 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(LL)= L/360 (1.33")
6 TTW+p MT20 4.0 6.0 Edge CALCULATED VERT. DEFL.(LL) = L/ 999 (0.25")
7 TMWW+t MT20 3.0 4.0 1.50 0.75 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 5-15, 7-15. DBS = 20-0-0 . CBF = ALLOWABLE DEFL.(TL)= L/360 (1.33")
8 TS-t MT20 3.0 6.0 152 LBS. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.47")
9 TMWW-t MT20 3.0 4.0 1.50 1.75
10 TMVW-t MT20 5.0 8.0 1.75 3.00 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). CSI: TC=0.93/1.00 (9-10:1) , BC=0.69/1.00 (17-18:1)
11 BMV1+t MT20 4.0 6.0 Edge 0.50 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, , WB=0.89/1.00 (3-17:2) , SSI=0.31/1.00 (2-3:2)
12 BMWW-t MT20 6.0 6.0 3.00 1.75 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12.
13 BMWW-t MT20 3.0 4.0 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
14 BS-t MT20 4.0 6.0 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN COMP=1.10 SHEAR=1.10 TENS= 1.10
15 BMWWW-t MT20 6.0 6.0 THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW
16 BS-t MT20 4.0 6.0 COMPANION LIVE LOAD FACTOR = 1.00
17 BMWW-t MT20 4.0 4.0 LOADING
18 BMWW-t MT20 6.0 6.0 3.00 1.50 TOTAL LOAD CASES: (8)
19 TRUSS PLATE MANUFACTURER IS NOT
19 TMBMVW1*+mMT20 8.0 10.0 2.75 2.50 CHORDS WEBS RESPONSIBLE FOR QUALITY CONTROL IN THE
MAX. FACTORED FACTORED MAX. FACTORED TRUSS MANUFACTURING PLANT .
Edge - INDICATES REFERENCE CORNER OF PLATE MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
TOUCHES EDGE OF CHORD. (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) NAIL VALUES
FR-TO FROM TO LENGTH FR-TO PLATE GRIP(DRY) SHEAR SECTION
1- 2 0 / 22 -109.0 -109.0 0.04 (1) 10.00 18- 3 -218 / 54 0.06 (1) (PSI) (PLI) (PLI)
2- 3 -4223 / 0 -109.0 -109.0 0.59 (1) 3.77 3-17 -723 / 0 0.89 (2) MAX MIN MAX MIN MAX MIN
3- 4 -3641 / 0 -109.0 -109.0 0.86 (1) 2.98 17- 5 0 / 487 0.11 (2) MT20 650 371 1747 788 1987 1873
4- 5 -3641 / 0 -109.0 -109.0 0.86 (1) 2.98 5-15 -1216 / 0 0.83 (2)
5- 6 -2780 / 0 -109.0 -109.0 0.78 (1) 3.36 15- 6 0 / 1790 0.40 (1) PLATE PLACEMENT TOL. = 0.250 inches
6- 7 -2781 / 0 -109.0 -109.0 0.78 (1) 3.35 15- 7 -1155 / 0 0.79 (3)
7- 8 -3580 / 0 -109.0 -109.0 0.86 (1) 2.98 13- 7 0 / 413 0.09 (3) PLATE ROTATION TOL. = 5.0 Deg.
8- 9 -3580 / 0 -109.0 -109.0 0.86 (1) 2.98 13- 9 -573 / 0 0.71 (3)
9-10 -3991 / 0 -109.0 -109.0 0.93 (1) 2.73 12- 9 -352 / 9 0.10 (1) JSI GRIP= 0.90 (12) (INPUT = 0.90 )
19- 2 -2599 / 0 0.0 0.0 0.26 (1) 5.33 2-18 0 / 3851 0.87 (1) JSI METAL= 0.87 (18) (INPUT = 1.00 )
11-10 -2500 / 0 0.0 0.0 0.25 (1) 5.42 12-10 0 / 3657 0.82 (1)

19-18 0/0 -18.5 -18.5 0.19 (8) 10.00


18-17 0 / 3835 -18.5 -18.5 0.69 (1) 10.00
17-16 0 / 3284 -18.5 -18.5 0.63 (1) 10.00
16-15 0 / 3284 -18.5 -18.5 0.63 (1) 10.00
15-14 0 / 3231 -18.5 -18.5 0.62 (1) 10.00
14-13 0 / 3231 -18.5 -18.5 0.62 (1) 10.00
13-12 0 / 3625 -18.5 -18.5 0.66 (1) 10.00
12-11 0/0 -18.5 -18.5 0.17 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A G1 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:53 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-zyDNOxjwkx0NlyuVKuy4PQB8m5etkRwWxORZxNz606i
10-8 5-0-11 4-10-3 6-0-10 6-0-10 6-0-10 2-6-6 4-10-3 5-0-11 10-8
Scale = 1:67.9
8x10
4x6 2x4 4x8 3x4
12x12
4 5 6 8 10- 9
7 4
5.75 12 3-12 T2 T3

4-4

1-12

5-4
3x4 4x4
3 10
1-1
-12
1T1 T12
5-8-3

5-8-3
W2 W3 W2 W1 W2 W1 W2 W4 W2

W6 W5 W5 W6
2 11

1-12
12
4-0

2-4
1 W8 W7 W7 W8
11-4

11-4
SB1
B1 B2 B3
2-12 1-8 3-0 3-12
1-12
20 17
23 22 21 19 18 16 15 14 13
6x6 8x16 MT18HS WB
10x10 7x8 4x4 6x6 4x8 4x10 4x4 5x12 10x14

10-8 40-6-0 10-8


5-0-11 4-10-3 6-0-10 6-0-10 6-0-10 2-6-6 4-10-3 5-0-11
40-6-0

TOTAL WEIGHT = 206 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY 2100F 1.8E SPF FACTORED MAXIMUM FACTORED INPUT REQRD *** SPECIAL LOADS ANALYSIS ***
4 - 7 2x6 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG GEOMETRY AND/OR BASIC LOADS CHANGED BY
7 - 9 2x6 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX USER.
9 - 12 2x4 DRY 2100F 1.8E SPF 23 3547 0 3547 0 0 5-8 4-4 LOADS WERE DERIVED FROM USER INPUT
23 - 2 2x8 DRY No.2 SPF 13 4819 0 4819 0 0 5-8 5-8 NO FURTHER MODIFICATIONS WERE MADE
13 - 11 2x8 DRY No.2 SPF
23 - 20 2x6 DRY No.2 SPF SPECIFIED LOADS:
20 - 17 2x6 DRY 2100F 1.8E SPF UNFACTORED REACTIONS TOP CH. LL = 31.3 PSF
17 - 13 2x6 DRY 2100F 1.8E SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS DL = 6.0 PSF
JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL BOT CH. LL = 0.0 PSF
ALL WEBS 2x3 DRY No.2 SPF 23 2486 1757 / 0 0/0 0/0 0/0 729 / 0 0/0 DL = 7.4 PSF
EXCEPT 13 3382 2367 / 0 0/0 0/0 0/0 1014 / 0 0/0 TOTAL LOAD = 44.7 PSF
2 - 22 2x4 DRY 2100F 1.8E SPF
14 - 11 2x4 DRY 2100F 1.8E SPF BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 23, 13 SPACING = 24.0 IN. C/C
BEARING SIZE FACTOR = 1.15 AT JNT(S) 13 ( BASED ON SUPPORT DEPTH = 1-8 )
DRY: SEASONED LUMBER.
BRACING LOADING IN FLAT SECTION BASED ON A SLOPE
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 2.35 FT. OF 6.00/12
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
GIRDER TYPE: CPrimeHip
PLATES (table is in inches) ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. SIDE SETBACK = 9-10-14
JT TYPE PLATES W LEN Y X END SETBACK = 4-10-0
2, 11, 13, 23 LOADING END WALL WIDTH = 5-8
2 TOTAL LOAD CASES: (8) CORNER FRAMING TYPE: CONVENTIONAL
3 TMWW-t MT20 3.0 4.0 1.50 1.75 END JACK TYPE: CONVENTIONAL
4 TTWW-m MT20 8.0 10.0 4.25 3.75 CHORDS WEBS APPLIED TO FRONT SIDE
5 TMWW-t MT20 4.0 6.0 1.75 3.00 MAX. FACTORED FACTORED MAX. FACTORED - ADDT'L LOADS BASED ON 55 % OF GSL.
6 TMW+w MT20 2.0 4.0 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX LOADS APPLIED TO FIRST 10-0-0 OF SPAN
7 TS-t MT20 4.0 8.0 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) MEASURED FROM THE RIGHT.
8 TMWW-t MT20 3.0 4.0 FR-TO FROM TO LENGTH FR-TO
9 TTWW-h MT20 12.0 12.0 5.25 10.25 1- 2 0 / 22 -109.0 -109.0 0.05 (1) 10.00 22- 3 -566 / 0 0.11 (1) *** NON STANDARD GIRDER ***
10 TMWW-t MT20 4.0 4.0 2.00 1.75 2- 3 -5921 / 0 -109.0 -109.0 0.58 (1) 3.20 3-21 -81 / 420 0.10 (3) ADDT'L USER-DEFINED LOADS APPLIED TO ALL
13 TMBMVW1*-t MT20 10.0 14.0 Edge 3- 4 -5903 / 0 -109.0 -109.0 0.56 (1) 3.21 21- 4 -53 / 212 0.05 (2) LOAD CASES.
14 BMWW-t MT20 5.0 12.0 2.25 3.75 4- 5 -7471 / 0 -109.0 -109.0 0.68 (1) 2.68 4-19 0 / 3021 0.75 (3)
15 BMWW-t MT20 4.0 4.0 5- 6 -8646 / 0 -109.0 -109.0 0.81 (1) 2.35 19- 5 -1892 / 0 0.83 (3) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
16 BMWW+t MT20 4.0 10.0 5.00 1.75 6- 7 -8646 / 0 -109.0 -109.0 0.80 (1) 2.37 5-18 0 / 1727 0.43 (3) SMALL BUILDING REQUIREMENTS OF PART 9,
17 BS-t MT18HS 8.0 16.0 7- 8 -8646 / 0 -109.0 -109.0 0.80 (1) 2.37 18- 6 -679 / 0 0.30 (2) NBCC 2015
18 BMWWW-t MT20 4.0 8.0 1.75 3.00 8- 9 -8878 / 0 -109.0 -109.0 0.56 (1) 2.55 18- 8 -479 / 0 0.62 (3)
19 BMWW-t MT20 6.0 6.0 3.00 1.50 9-10 -8455 / 0 -109.0 -109.0 0.80 (1) 2.50 16- 8 -504 / 0 0.22 (2) THIS DESIGN COMPLIES WITH:
20 BS-t MT20 6.0 6.0 10-11 -8229 / 0 -109.0 -109.0 0.81 (1) 2.56 16- 9 0 / 2991 0.74 (2) - PART 9 OF BCBC 2018 , NBC-2019AE
21 BMWW-t MT20 4.0 4.0 11-12 0 / 22 -109.0 -109.0 0.05 (1) 10.00 15- 9 -33 / 228 0.06 (8) - PART 9 OF OBC 2012 (2019 AMENDMENT)
22 BMWW-t MT20 7.0 8.0 4.00 2.75 23- 2 -3471 / 0 0.0 0.0 0.18 (1) 6.37 15-10 0 / 684 0.17 (2) - CSA 086-14
23 TMBMVW1*-t MT20 10.0 10.0 Edge 13-11 -4696 / 0 0.0 0.0 0.25 (1) 5.60 14-10 -791 / 0 0.16 (1) - TPIC 2014
2-22 0 / 5392 0.44 (1)
Edge - INDICATES REFERENCE CORNER OF PLATE 23-22 0/0 -18.5 -18.5 0.11 (1) 10.00 14-11 0 / 7484 0.62 (1) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
TOUCHES EDGE OF CHORD. 22-21 0 / 5361 -18.5 -18.5 0.80 (1) 10.00 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
21-20 0 / 5320 -18.5 -18.5 0.77 (1) 10.00 LIVE LOAD
WB - INDICATES BLOCKING REQUIRED 20-19 0 / 5320 -18.5 -18.5 0.77 (1) 10.00
19-18 0 / 7470 -18.5 -18.5 0.44 (1) 10.00 ALLOWABLE DEFL.(LL)= L/360 (1.35")
18-17 0 / 8876 -18.5 -18.5 0.55 (1) 10.00 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.43")
17-16 0 / 8876 -18.5 -18.5 0.55 (1) 10.00 ALLOWABLE DEFL.(TL)= L/360 (1.35")
16-15 0 / 7629 -18.5 -18.5 0.47 (1) 10.00 CALCULATED VERT. DEFL.(TL) = L/ 640 (0.76")
15-14 0 / 7441 -29.5 -29.5 0.49 (1) 10.00
14-13 0/0 -29.5 -29.5 0.10 (1) 10.00 CSI: TC=0.81/1.00 (10-11:1) , BC=0.80/1.00
(21-22:1) , WB=0.83/1.00 (5-19:3) , SSI=0.26/1.00
FACTORED CONCENTRATED LOADS (LBS) (2-3:2)
JT LOC. LC1 MAX- MAX+ FACE DIR. TYPE HEEL CONN.
9 30-7-2 -600 -600 --- FRONT VERT TOTAL --- C1 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.00
16 28-0-12 -2289 -2289 --- FRONT VERT TOTAL --- C1 COMP=1.00 SHEAR=1.00 TENS= 1.00

CONNECTION REQUIREMENTS COMPANION LIVE LOAD FACTOR = 1.00

1) C1: A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED. AUTOSOLVE HEELS OFF

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING TRUSS PLATE MANUFACTURER IS NOT
AS PER NBCC 4.1.6.2.(8) RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873
MT18HS 586 403 2455 1382 3163 3004

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

2023-06-15 JSI GRIP= 0.89 (19) (INPUT = 0.90 )


JSI METAL= 0.98 (9) (INPUT = 1.00 )
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A G2 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:53 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-zyDNOxjwkx0NlyuVKuy4PQB5O5f6kPfWxORZxNz606i
10-8 6-11-2 6-8-10 6-7-4 6-7-4 6-8-10 6-11-2 10-8
Scale = 1:71.0
5.75 12 6x8
2x4 6x8
5 6 7

2-0

2-0
2-0 T3 2-0
3x6
T2 T2 3x6
4 8
3x4 3x4
3 9
1-1
-12
7-5-11
7-3-11

7-3-11
1 2
W1 W2 W1 W2 W1
T1 T1
W4 W3 W3 W4

2 2-8 2-8 10
1 11
11-4

W6 W6

11-4
W5 W5
B1 B2 B1
2-12

2-12
3-0 3-0
17 15
20 19 18 16 14 13 12
3x8 3x8
8x10 5x8 4x4 4x8 4x4 5x8 8x10
10-8 40-6-0 10-8
6-11-2 6-8-10 6-7-4 6-7-4 6-8-10 6-11-2
40-6-0

TOTAL WEIGHT = 160 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY 2100F 1.8E SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 7 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
7 - 8 2x4 DRY No.2 SPF 20 2684 0 2684 0 0 5-8 5-4 BOT CH. LL = 0.0 PSF
8 - 11 2x4 DRY 2100F 1.8E SPF 12 2684 0 2684 0 0 5-8 5-4 DL = 7.4 PSF
20 - 2 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
12 - 10 2x4 DRY No.2 SPF
20 - 17 2x4 DRY No.2 SPF UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
17 - 15 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
15 - 12 2x4 DRY No.2 SPF JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
20 1882 1328 / 0 0/0 0/0 0/0 554 / 0 0/0 LOADING IN FLAT SECTION BASED ON A SLOPE
ALL WEBS 2x3 DRY No.2 SPF 12 1882 1328 / 0 0/0 0/0 0/0 554 / 0 0/0 OF 6.00/12
EXCEPT
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 20, 12 THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
DRY: SEASONED LUMBER. SMALL BUILDING REQUIREMENTS OF PART 9,
BRACING NBCC 2015
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 2.64 FT.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , NBC-2019AE
PLATES (table is in inches) ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. - PART 9 OF OBC 2012 (2019 AMENDMENT)
JT TYPE PLATES W LEN Y X - CSA 086-14
2, 10, 12, 20 LOADING - TPIC 2014
2 TOTAL LOAD CASES: (8)
3 TMWW-t MT20 3.0 4.0 1.50 1.75 (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
4 TS-t MT20 3.0 6.0 CHORDS WEBS LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
5 TMTWW-l MT20 6.0 8.0 3.00 2.00 MAX. FACTORED FACTORED MAX. FACTORED LIVE LOAD
6 TMW+w MT20 2.0 4.0 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
7 TMTWW-l MT20 6.0 8.0 3.00 2.00 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) ALLOWABLE DEFL.(LL)= L/360 (1.35")
8 TS-t MT20 3.0 6.0 FR-TO FROM TO LENGTH FR-TO CALCULATED VERT. DEFL.(LL) = L/ 999 (0.28")
9 TMWW-t MT20 3.0 4.0 1.50 1.75 1- 2 0 / 22 -109.0 -109.0 0.04 (1) 10.00 19- 3 -224 / 54 0.06 (1) ALLOWABLE DEFL.(TL)= L/360 (1.35")
12 TMBMVW1*+mMT20 8.0 10.0 2.75 2.50 2- 3 -4303 / 0 -109.0 -109.0 0.61 (1) 3.70 3-18 -758 / 3 0.98 (2) CALCULATED VERT. DEFL.(TL) = L/ 977 (0.50")
13 BMWW-t MT20 5.0 8.0 2.50 3.00 3- 4 -3679 / 0 -109.0 -109.0 0.96 (1) 2.70 18- 5 0 / 509 0.11 (2)
14 BMWW-t MT20 4.0 4.0 4- 5 -3679 / 0 -109.0 -109.0 0.96 (1) 2.70 5-16 0 / 1033 0.23 (3) CSI: TC=0.96/1.00 (7-9:1) , BC=0.73/1.00 (13-14:1) ,
15 BS-t MT20 3.0 8.0 5- 6 -3815 / 0 -109.0 -109.0 0.89 (1) 2.64 16- 6 -980 / 0 0.93 (1) WB=0.98/1.00 (9-14:3) , SSI=0.35/1.00 (5-6:2)
16 BMWWW-t MT20 4.0 8.0 6- 7 -3815 / 0 -109.0 -109.0 0.89 (1) 2.64 16- 7 0 / 1033 0.23 (2)
17 BS-t MT20 3.0 8.0 7- 8 -3679 / 0 -109.0 -109.0 0.96 (1) 2.70 14- 7 0 / 509 0.11 (3) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
18 BMWW-t MT20 4.0 4.0 8- 9 -3679 / 0 -109.0 -109.0 0.96 (1) 2.70 14- 9 -758 / 3 0.98 (3) COMP=1.10 SHEAR=1.10 TENS= 1.10
19 BMWW-t MT20 5.0 8.0 2.50 3.00 9-10 -4303 / 0 -109.0 -109.0 0.61 (1) 3.70 13- 9 -224 / 54 0.06 (1)
20 TMBMVW1*+mMT20 8.0 10.0 2.75 2.50 10-11 0 / 22 -109.0 -109.0 0.04 (1) 10.00 2-19 0 / 3930 0.88 (1) COMPANION LIVE LOAD FACTOR = 1.00
20- 2 -2627 / 0 0.0 0.0 0.26 (1) 5.30 13-10 0 / 3930 0.88 (1)
12-10 -2627 / 0 0.0 0.0 0.26 (1) 5.30
TRUSS PLATE MANUFACTURER IS NOT
20-19 0/0 -18.5 -18.5 0.19 (8) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
19-18 0 / 3913 -18.5 -18.5 0.73 (1) 10.00 TRUSS MANUFACTURING PLANT .
18-17 0 / 3304 -18.5 -18.5 0.63 (1) 10.00
17-16 0 / 3304 -18.5 -18.5 0.63 (1) 10.00 NAIL VALUES
16-15 0 / 3304 -18.5 -18.5 0.63 (1) 10.00 PLATE GRIP(DRY) SHEAR SECTION
15-14 0 / 3304 -18.5 -18.5 0.63 (1) 10.00 (PSI) (PLI) (PLI)
14-13 0 / 3913 -18.5 -18.5 0.73 (1) 10.00 MAX MIN MAX MIN MAX MIN
13-12 0/0 -18.5 -18.5 0.19 (8) 10.00 MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.89 (20) (INPUT = 0.90 )


JSI METAL= 0.99 (17) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A G3 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:54 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-R9nlbHkYVE8EM5ShucTJyekK8VzSTsWfA2B7Tqz606h
10-8 5-11-3 5-8-11 5-8-11 5-8-13 5-8-11 5-8-11 5-5-11
6x6 4x10 Scale = 1:85.7
5.75 12
6 7

2-0

2-4 2-0
T3 3-4

3x4 T2 T2 3x4
3x6
5 8 3x6
4 1-4 9
O3
9-3-3
9-1-3

9-1-3
4x8 4x8
O2 O4 10
3 W2 W1 W2 2-8
2-8 T4

1-1

2
T1

1-1
O1 W4 W3 W3 W4 2x4

2
8x10
O1 O5 11
W6 W5 W5 W7
1 2

1-1-14
W8

1-8
W9
11-4

B1 B2 B3
2-9
19 18 17 14 13 12
16 15
3x4 4x6 4x6 3x4 7x8
4x6 3x4

10-8 40-0-8
8-9-9 8-7-1 5-8-13 8-7-1 8-4-1
40-0-8

TOTAL WEIGHT = 166 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 6 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 7 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
7 - 9 2x4 DRY No.2 SPF 19 2655 0 2655 0 0 5-8 2-14 BOT CH. LL = 0.0 PSF
9 - 11 2x4 DRY No.2 SPF 12 2552 0 2552 0 0 MECHANICAL DL = 7.4 PSF
19 - 2 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
12 - 11 2x4 DRY No.2 SPF A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 12. MINIMUM
19 - 17 2x4 DRY No.2 SPF BEARING LENGTH AT JOINT 12 = 1-8. SPACING = 24.0 IN. C/C
17 - 14 2x4 DRY No.2 SPF
14 - 12 2x4 DRY No.2 SPF
LOADING IN FLAT SECTION BASED ON A SLOPE
ALL WEBS 2x3 DRY No.2 SPF UNFACTORED REACTIONS OF 6.00/12
EXCEPT 1ST LCASE MAX./MIN. COMPONENT REACTIONS
19 - 3 2x4 DRY No.2 SPF JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
10 - 12 2x4 DRY No.2 SPF 19 1861 1313 / 0 0/0 0/0 0/0 548 / 0 0/0 SMALL BUILDING REQUIREMENTS OF PART 9,
12 1791 1254 / 0 0/0 0/0 0/0 537 / 0 0/0 NBCC 2015
DRY: SEASONED LUMBER.
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 19 THIS DESIGN COMPLIES WITH:
- PART 9 OF BCBC 2018 , NBC-2019AE
BRACING - PART 9 OF OBC 2012 (2019 AMENDMENT)
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.00 FT. - CSA 086-14
PLATES (table is in inches) MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. - TPIC 2014
JT TYPE PLATES W LEN Y X
2 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
2 TMBMVW1*+mMT20 8.0 10.0 Edge 2.50 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMWW-t MT20 4.0 8.0 1.75 2.50 2x4 DRY SPF No.2 T-BRACE AT 5-16, 7-16, 8-15, 10-12 LIVE LOAD
4 TS-t MT20 3.0 6.0 2x4 DRY SPF No.2 I-BRACE AT 3-19
5 TMWW+t MT20 3.0 4.0 2.00 1.25 ALLOWABLE DEFL.(LL)= L/360 (1.33")
6 TMTW-l MT20 6.0 6.0 Edge FASTEN T AND I-BRACES TO NARROW EDGE OF WEB WITH ONE ROW PER PLY OF 3" CALCULATED VERT. DEFL.(LL) = L/ 999 (0.24")
7 TMTWW-l MT20 4.0 10.0 2.25 3.25 COMMON WIRE NAILS @ 6" O.C. WITH 3" MINIMUM END DISTANCE. BRACE MUST COVER 90% ALLOWABLE DEFL.(TL)= L/360 (1.33")
8 TMWW-t MT20 3.0 4.0 OF WEB LENGTH. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.47")
9 TS-t MT20 3.0 6.0
10 TMWW-t MT20 4.0 8.0 1.75 2.50 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN CSI: TC=0.70/1.00 (3-5:1) , BC=0.78/1.00 (18-19:1) ,
11 TMV+p MT20 2.0 4.0 THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW WB=1.00/1.00 (10-12:1) , SSI=0.27/1.00 (7-8:3)
12 BMVW1-t MT20 7.0 8.0 Edge
13 BMWW-t MT20 3.0 4.0 LOADING DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
14 BS-t MT20 4.0 6.0 TOTAL LOAD CASES: (8) COMP=1.10 SHEAR=1.10 TENS= 1.10
15 BMWW+t MT20 3.0 4.0 1.50 1.50
16 BMWWW-t MT20 4.0 6.0 CHORDS WEBS COMPANION LIVE LOAD FACTOR = 1.00
17 BS-t MT20 4.0 6.0 MAX. FACTORED FACTORED MAX. FACTORED
18 BMWW+t MT20 3.0 4.0 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
19 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) TRUSS PLATE MANUFACTURER IS NOT
FR-TO FROM TO LENGTH FR-TO RESPONSIBLE FOR QUALITY CONTROL IN THE
Edge - INDICATES REFERENCE CORNER OF PLATE 1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 3-18 -320 / 117 0.11 (2) TRUSS MANUFACTURING PLANT .
TOUCHES EDGE OF CHORD. 2- 3 0 / 25 -109.0 -109.0 0.46 (2) 10.00 18- 5 0 / 468 0.11 (2)
3- 4 -4010 / 0 -109.0 -109.0 0.70 (1) 3.00 5-16 -944 / 0 0.53 (2) NAIL VALUES
4- 5 -4010 / 0 -109.0 -109.0 0.70 (1) 3.00 16- 6 0 / 754 0.17 (1) PLATE GRIP(DRY) SHEAR SECTION
5- 6 -3144 / 0 -109.0 -109.0 0.60 (1) 3.42 16- 7 -384 / 432 0.35 (3) (PSI) (PLI) (PLI)
6- 7 -2835 / 0 -109.0 -109.0 0.59 (1) 3.53 15- 7 0 / 757 0.17 (3) MAX MIN MAX MIN MAX MIN
7- 8 -3124 / 0 -109.0 -109.0 0.60 (1) 3.42 15- 8 -867 / 0 0.49 (3) MT20 650 371 1747 788 1987 1873
8- 9 -3849 / 0 -109.0 -109.0 0.69 (1) 3.06 8-13 0 / 340 0.08 (3)
9-10 -3849 / 0 -109.0 -109.0 0.69 (1) 3.06 13-10 -172 / 199 0.06 (3) PLATE PLACEMENT TOL. = 0.250 inches
10-11 0 / 24 -109.0 -109.0 0.41 (3) 10.00 19- 3 -4393 / 0 0.99 (1)
19- 2 -363 / 0 0.0 0.0 0.04 (1) 7.81 10-12 -4190 / 0 1.00 (1) PLATE ROTATION TOL. = 5.0 Deg.
12-11 -238 / 0 0.0 0.0 0.02 (1) 7.81
JSI GRIP= 0.89 (16) (INPUT = 0.90 )
19-18 0 / 3789 -18.5 -18.5 0.78 (1) 10.00 JSI METAL= 0.83 (2) (INPUT = 1.00 )
18-17 0 / 3443 -18.5 -18.5 0.73 (1) 10.00
17-16 0 / 3443 -18.5 -18.5 0.73 (1) 10.00
16-15 0 / 2816 -18.5 -18.5 0.56 (1) 10.00
15-14 0 / 3363 -18.5 -18.5 0.71 (1) 10.00
14-13 0 / 3363 -18.5 -18.5 0.71 (1) 10.00
13-12 0 / 3533 -18.5 -18.5 0.73 (1) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A HGF 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:42 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-GV2Y7kkD6sF4J8kYc5pKiIt38f2AyGYKY?FW8wzRBRB
10-8 6-6-0 6-6-0 10-8
4x6 Scale = 1:33.1

5.75 12
6
4

7
4-0-10

3 T1 T1
ST3
ST2 ST2

ST1 ST1 8
2
9
1 W1 W1
11-4

11-4
B1

10-8 16 15 14 13 13-10-8 12 11 10
13-0-0
13-0-0

TOTAL WEIGHT = 44 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
16 - 2 2x3 DRY No.2 SPF SPECIFIED LOADS:
1 - 5 2x4 DRY No.2 SPF THIS TRUSS DESIGNED FOR CONTINUOUS BEARINGS. TOP CH. LL = 31.3 PSF
5 - 9 2x4 DRY No.2 SPF DL = 6.0 PSF
10 - 8 2x3 DRY No.2 SPF THIS TRUSS REQUIRES RIGID SHEATHING ON EXPOSED FACE. BOT CH. LL = 0.0 PSF
16 - 10 2x4 DRY No.2 SPF DL = 7.4 PSF
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) TOTAL LOAD = 44.7 PSF
ALL WEBS 2x3 DRY No.2 SPF
ALL GABLE WEBS BRACING SPACING = 24.0 IN. C/C
2x3 DRY No.2 SPF TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
DRY: SEASONED LUMBER. MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
SMALL BUILDING REQUIREMENTS OF PART 9,
GABLE STUDS SPACED AT 2-0-0 OC. ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. NBCC 2015

LOADING THIS DESIGN COMPLIES WITH:


TOTAL LOAD CASES: (8) - PART 9 OF BCBC 2018 , ABC 2019
- PART 9 OF OBC 2012 (2019 AMENDMENT)
PLATES (table is in inches) CHORDS WEBS - CSA 086-14
JT TYPE PLATES W LEN Y X MAX. FACTORED FACTORED MAX. FACTORED - TPIC 2014
2 TMV+p MT20 2.0 4.0 MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
3, 4, 6, 7 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) DESIGN ASSUMPTIONS
3 TMW+w MT20 2.0 4.0 FR-TO FROM TO LENGTH FR-TO -OVERHANG NOT TO BE ALTERED OR CUT OFF.
5 TTW-p MT20 4.0 6.0 16- 2 -253 / 0 0.0 0.0 0.02 (1) 7.81 13- 5 -216 / 0 0.05 (1)
8 TMV+p MT20 2.0 4.0 1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 14- 4 -224 / 0 0.04 (2) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
10 BMV1+p MT20 2.0 4.0 2- 3 -30 / 0 -109.0 -109.0 0.08 (2) 6.25 15- 3 -236 / 0 0.04 (1) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
11, 12, 13, 14, 15 3- 4 -20 / 0 -109.0 -109.0 0.06 (1) 6.25 12- 6 -224 / 0 0.04 (3) LIVE LOAD
11 BMW1+w MT20 2.0 4.0 4- 5 -14 / 0 -109.0 -109.0 0.05 (1) 6.25 11- 7 -236 / 0 0.04 (1)
16 BMV1+p MT20 2.0 4.0 5- 6 -14 / 0 -109.0 -109.0 0.05 (1) 6.25
6- 7 -20 / 0 -109.0 -109.0 0.06 (1) 6.25 CSI: TC=0.08/1.00 (7-8:3) , BC=0.03/1.00 (10-11:8) ,
7- 8 -30 / 0 -109.0 -109.0 0.08 (3) 6.25 WB=0.05/1.00 (5-13:1) , SSI=0.10/1.00 (7-8:3)
8- 9 0 / 22 -109.0 -109.0 0.07 (1) 10.00
10- 8 -253 / 0 0.0 0.0 0.02 (1) 7.81 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
COMP=1.10 SHEAR=1.10 TENS= 1.10
16-15 0 / 25 -18.5 -18.5 0.03 (8) 10.00
15-14 0 / 17 -18.5 -18.5 0.02 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00
14-13 0 / 12 -18.5 -18.5 0.02 (8) 10.00
13-12 0 / 12 -18.5 -18.5 0.02 (8) 10.00
12-11 0 / 17 -18.5 -18.5 0.02 (8) 10.00 TRUSS PLATE MANUFACTURER IS NOT
11-10 0 / 25 -18.5 -18.5 0.03 (8) 10.00 RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING NAIL VALUES


AS PER NBCC 4.1.6.2.(8) PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.17 (10) (INPUT = 0.90 )


JSI METAL= 0.12 (8) (INPUT = 1.00 )

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A I 4 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:43 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-khcwK4lrt9NxxIJlApKZFVQ2L3EQhWkUmf?3gNzRBRA
10-8 7-1-4 6-10-12 6-10-12 7-1-4
4x6 Scale = 1:65.9
5.75 12
5

3x6 T2

4
4x6 4x6
3 6
T3
7-7-12

W1 W1
W3 W3
2x4 2x4
W2 W2
7
2
1 W4 W4
11-4

11-4
B1 B2

11 10 9
12 8
4x6 4x4 3x6 4x4 4x6
10-8 28-0-0
9-4-13 9-2-5 9-4-13
28-0-0

TOTAL WEIGHT = 4 X 108 = 433 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 7 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
12 - 2 2x4 DRY No.2 SPF 12 1887 0 1887 0 0 5-8 2-1 BOT CH. LL = 0.0 PSF
8 - 7 2x4 DRY No.2 SPF 8 1785 0 1785 0 0 MECHANICAL DL = 7.4 PSF
12 - 10 2x4 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
10 - 8 2x4 DRY No.2 SPF A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 8. MINIMUM BEARING
LENGTH AT JOINT 8 = 1-15. SPACING = 24.0 IN. C/C
ALL WEBS 2x3 DRY No.2 SPF
EXCEPT THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
12 - 3 2x4 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
6 - 8 2x4 DRY No.2 SPF UNFACTORED REACTIONS NBCC 2015
1ST LCASE MAX./MIN. COMPONENT REACTIONS
DRY: SEASONED LUMBER. JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS DESIGN COMPLIES WITH:
12 1322 936 / 0 0/0 0/0 0/0 386 / 0 0/0 - PART 9 OF BCBC 2018 , ABC 2019
8 1252 877 / 0 0/0 0/0 0/0 375 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 12 - TPIC 2014
PLATES (table is in inches)
JT TYPE PLATES W LEN Y X BRACING (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
2 TMV+p MT20 2.0 4.0 TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 3.30 FT. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMWW-t MT20 4.0 6.0 2.00 1.50 MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. LIVE LOAD
4 TS-t MT20 3.0 6.0
5 TTWW+p MT20 4.0 6.0 Edge ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(LL)= L/360 (0.93")
6 TMWW-t MT20 4.0 6.0 2.00 1.50 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.14")
7 TMV+p MT20 2.0 4.0 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 3-12, 6-8. DBS = 16-0-0 . CBF = ALLOWABLE DEFL.(TL)= L/360 (0.93")
8 BMVW1-t MT20 4.0 6.0 1.75 2.00 288 LBS. CALCULATED VERT. DEFL.(TL) = L/ 999 (0.31")
9 BMWW-t MT20 4.0 4.0 2.00 1.75
10 BS-t MT20 3.0 6.0 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE). CSI: TC=0.88/1.00 (2-3:2) , BC=0.60/1.00 (11-12:1) ,
11 BMWW-t MT20 4.0 4.0 2.00 1.75 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, WB=0.89/1.00 (3-12:1) , SSI=0.33/1.00 (3-5:2)
12 BMVW1-t MT20 4.0 6.0 1.75 2.00 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12.
DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
Edge - INDICATES REFERENCE CORNER OF PLATE END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN COMP=1.10 SHEAR=1.10 TENS= 1.10
TOUCHES EDGE OF CHORD. THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW
COMPANION LIVE LOAD FACTOR = 1.00
LOADING
TOTAL LOAD CASES: (8)
TRUSS PLATE MANUFACTURER IS NOT
CHORDS WEBS RESPONSIBLE FOR QUALITY CONTROL IN THE
MAX. FACTORED FACTORED MAX. FACTORED TRUSS MANUFACTURING PLANT .
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) NAIL VALUES
FR-TO FROM TO LENGTH FR-TO PLATE GRIP(DRY) SHEAR SECTION
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 5- 9 0 / 928 0.21 (3) (PSI) (PLI) (PLI)
2- 3 0 / 40 -109.0 -109.0 0.88 (2) 10.00 9- 6 -701 / 0 0.26 (3) MAX MIN MAX MIN MAX MIN
3- 4 -2438 / 0 -109.0 -109.0 0.86 (1) 3.30 11- 5 0 / 928 0.21 (2) MT20 650 371 1747 788 1987 1873
4- 5 -2438 / 0 -109.0 -109.0 0.86 (1) 3.30 3-11 -701 / 0 0.26 (2)
5- 6 -2438 / 0 -109.0 -109.0 0.86 (1) 3.30 12- 3 -2878 / 0 0.89 (1) PLATE PLACEMENT TOL. = 0.250 inches
6- 7 0 / 40 -109.0 -109.0 0.88 (3) 10.00 6- 8 -2878 / 0 0.89 (1)
12- 2 -392 / 0 0.0 0.0 0.04 (1) 7.81 PLATE ROTATION TOL. = 5.0 Deg.
8- 7 -290 / 0 0.0 0.0 0.03 (1) 7.81
JSI GRIP= 0.88 (6) (INPUT = 0.90 )
12-11 0 / 2501 -18.5 -18.5 0.60 (1) 10.00 JSI METAL= 0.64 (3) (INPUT = 1.00 )
11-10 0 / 1696 -18.5 -18.5 0.49 (8) 10.00
10- 9 0 / 1696 -18.5 -18.5 0.49 (8) 10.00
9- 8 0 / 2501 -18.5 -18.5 0.60 (1) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A IGF 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.530 S Feb 3 2022 MiTek Industries, Inc. Thu Apr 13 09:18:43 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-khcwK4lrt9NxxIJlApKZFVQ0q3H4hYEUmf?3gNzRBRA
10-8 7-1-4 6-10-12 6-10-12 7-1-4
Scale = 1:73.2
4x6
5.75 12 3x6
5

3x6 T2ST6

3x4 4 W1 ST6 4x4


3 6
7-7-12 T3
ST3 ST3
ST8 W1
ST5 ST5
T1
ST1 ST4 ST4 W3
ST7 ST7
W3 ST2 W2 W2 ST2 7
2 ST1
1
11-4

W4 W4

11-4
B1 B2

9
3x4 3x4 8
12 11 10 37 4x4 4x4

10-8 4x6
28-0-0
9-4-13 9-2-5 9-4-13
28-0-0

TOTAL WEIGHT = 140 lb


LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 4 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
4 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 7 2x4 DRY 2100F 1.8E SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
12 - 2 2x3 DRY No.2 SPF 11 2099 0 2099 0 0 15-5-8 ( 13-11-0
3-14
) BOT CH. LL = 0.0 PSF
8 - 7 2x3 DRY No.2 SPF 12 475 0 568 0 0 15-5-8 ( 13-11-0
3-14
) DL = 7.4 PSF
12 - 10 2x4 DRY No.2 SPF 8 1058 0 1058 0 0 5-8 1-8 TOTAL LOAD = 44.7 PSF
10 - 8 2x4 DRY No.2 SPF 37 40 0 40 0 0 15-5-8 ( 13-11-0
3-14
)
SPACING = 24.0 IN. C/C
ALL WEBS 2x3 DRY No.2 SPF VALUE IN PARENTHESIS INDICATES EFFECTIVE BEARING LENGTH
ALL GABLE WEBS THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
2x3 DRY No.2 SPF SMALL BUILDING REQUIREMENTS OF PART 9,
DRY: SEASONED LUMBER. UNFACTORED REACTIONS NBCC 2015
1ST LCASE MAX./MIN. COMPONENT REACTIONS
GABLE STUDS SPACED AT 2-0-0 OC. JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL THIS DESIGN COMPLIES WITH:
11 1473 1031 / 0 0/0 0/0 0/0 442 / 0 0/0 - PART 9 OF BCBC 2018 , ABC 2019
12 331 304 / -63 0/0 0/0 0/0 90 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
8 742 520 / 0 0/0 0/0 0/0 223 / 0 0/0 - CSA 086-14
37 28 20 / 0 0/0 0/0 0/0 8/0 0/0 - TPIC 2014
PLATES (table is in inches)
JT TYPE PLATES W LEN Y X BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 11, 12, 8, 37 (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
2 TMV+p MT20 2.0 4.0 LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
3 TMWW-t MT20 3.0 4.0 BRACING LIVE LOAD
4 TS-t MT20 3.0 6.0 TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT.
5 TTWW+p MT20 4.0 6.0 Edge MAX. UNBRACED BOTTOM CHORD LENGTH = 6.25 FT OR RIGID CEILING DIRECTLY APPLIED. ALLOWABLE DEFL.(LL)= L/360 (0.42")
5 NP-p MT20 3.0 6.0 0.75 3.00 CALCULATED VERT. DEFL.(LL) = L/ 999 (0.06")
6 TMWW-t MT20 4.0 4.0 2.00 1.50 ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. ALLOWABLE DEFL.(TL)= L/360 (0.42")
7 TMV+p MT20 2.0 4.0 CALCULATED VERT. DEFL.(TL) = L/ 544 (0.28")
8 BMVW1-t MT20 4.0 4.0 1.75 1.50 1 - 2x4 DRY SPF No.2 LATERAL BRACE(S) AT 1/ 2 LENGTH OF 5-11, 6-8. DBS = 20-0-0 . CBF =
9 BMWW-t MT20 4.0 4.0 2.00 1.75 175 LBS. CSI: TC=0.98/1.00 (3-5:1) , BC=0.43/1.00 (8-9:8) ,
10 BSW+l MT20 4.0 6.0 WB=0.73/1.00 (5-11:1) , SSI=0.34/1.00 (2-3:1)
11 BMWW1+t MT20 3.0 4.0 1.75 1.50 DBS = DIAGONAL BRACE SPACING (MAX). CBF = CUMULATIVE BRACING FORCE (PER BRACE).
12 BMVW1-t MT20 3.0 4.0 FASTEN LATERAL BRACE(S) USING (0.144"X3") NAILS : 1 NAIL FOR 2x3 BRACE(S), 2 FOR 1x4, DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
13, 13, 14, 15, 16, 17, 18, 18, 19, 20, 21, 22, 23, 24, 25, 26, 2x4, 2x5, 3 FOR 2x6, 4 FOR 2x8, 5 FOR 2x10, AND 6 FOR 2x12. COMP=1.10 SHEAR=1.10 TENS= 1.10
27, 27, 28, 29, 30, 31, 32, 32, 33, 34, 35, 36
13 NP+w MT20 2.0 4.0 END VERTICAL(S) MUST BE SHEATHED OR HAVE BRACES AS INDICATED IN COMPANION LIVE LOAD FACTOR = 1.00
THE MAX. UNBRACED LENGTH COLUMN OF THE TABLE BELOW
Edge - INDICATES REFERENCE CORNER OF PLATE
TOUCHES EDGE OF CHORD. LOADING TRUSS PLATE MANUFACTURER IS NOT
TOTAL LOAD CASES: (8) RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .
CHORDS WEBS
MAX. FACTORED FACTORED MAX. FACTORED NAIL VALUES
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX PLATE GRIP(DRY) SHEAR SECTION
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) (PSI) (PLI) (PLI)
FR-TO FROM TO LENGTH FR-TO MAX MIN MAX MIN MAX MIN
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 5- 9 0 / 954 0.21 (3) MT20 650 371 1747 788 1987 1873
2- 3 0 / 41 -109.0 -109.0 0.92 (1) 10.00 9- 6 -761 / 0 0.28 (3)
3- 4 0 / 421 -109.0 -109.0 0.98 (1) 10.00 11- 5 -1394 / 0 0.73 (1) PLATE PLACEMENT TOL. = 0.250 inches
4- 5 0 / 421 -109.0 -109.0 0.98 (1) 10.00 3-11 -863 / 0 0.31 (1)
5- 6 -957 / 0 -109.0 -109.0 0.63 (1) 6.25 12- 3 -221 / 213 0.30 (2) PLATE ROTATION TOL. = 5.0 Deg.
6- 7 0 / 40 -109.0 -109.0 0.58 (3) 10.00 6- 8 -1401 / 0 0.62 (1)
12- 2 -389 / 0 0.0 0.0 0.05 (2) 7.81 JSI GRIP= 0.89 (9) (INPUT = 0.90 )
8- 7 -290 / 0 0.0 0.0 0.04 (1) 7.81 JSI METAL= 0.60 (5) (INPUT = 1.00 )

12-11 -185 / 192 -18.5 -18.5 0.37 (8) 6.25


11-10 0 / 323 -18.5 -18.5 0.39 (8) 10.00
10-37 0 / 323 -18.5 -18.5 0.39 (8) 10.00
37- 9 0 / 323 -18.5 -18.5 0.37 (8) 10.00
9- 8 0 / 1218 -18.5 -18.5 0.43 (8) 10.00

TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING


AS PER NBCC 4.1.6.2.(8)

2023-04-13
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JF 12 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:54 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-R9nlbHkYVE8EM5ShucTJyekUvV9PT5BfA2B7Tqz606h
10-8 2-1-0
Scale = 1:17.7
3
5.75 12

2x4
T1

1-11-4

1-11-4
2

1-6-10
1 W1

11-4
B1

2x4 4
10-8 2-1-0
2-1-0
2-1-0

TOTAL WEIGHT = 12 X 7 = 82 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 266 0 266 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 85 0 85 0 0 1-8 1-8 DL = 7.4 PSF
4 17 0 19 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 184 140 / 0 0/0 0/0 0/0 44 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 59 49 / 0 0/0 0/0 0/0 9/0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 13 0/0 0/0 0/0 0/0 13 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (9) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.00")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.08/1.00 (2-3:1) , BC=0.02/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.10/1.00 (2-3:1)
5- 2 -244 / 0 0.0 0.0 0.01 (8) 7.81
1- 2 0 / 22 -109.0 -109.0 0.07 (9) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -12 / 0 -109.0 -109.0 0.08 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.02 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
CANTILEVER ANALYSIS HAS BEEN CONSIDERED IN THIS DESIGN TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.14 (2) (INPUT = 0.90 )


JSI METAL= 0.10 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG 2 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:54 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-R9nlbHkYVE8EM5ShucTJyekQyV8GT5BfA2B7Tqz606h
10-8 4-10-0
Scale = 1:44.0
3

10.75 12

T1

5-8-3

5-8-3
5-2-3
2x4

1-4-4
1 W1

B1

5 4
2x4
10-8 4-10-0
4-10-0
4-10-0

TOTAL WEIGHT = 2 X 16 = 31 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 487 0 487 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 198 0 198 0 0 1-8 1-8 DL = 7.4 PSF
4 38 0 42 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 339 250 / 0 0/0 0/0 0/0 89 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 135 114 / 0 0/0 0/0 0/0 22 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 30 0/0 0/0 0/0 0/0 30 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.02")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.33/1.00 (2-3:1) , BC=0.09/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.19/1.00 (2-3:1)
5- 2 -435 / 0 0.0 0.0 0.07 (8) 7.81
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -44 / 0 -109.0 -109.0 0.33 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.09 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.31 (2) (INPUT = 0.90 )


JSI METAL= 0.23 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG1 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:55 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-vLL7pdlAGYG5_F1tSJ_YUrGdjvUVCYQpPiwg0Gz606g
10-8 3-9-5 1-0-11
Scale = 1:37.6
3

10.75 12

4-8-14
T1

2x4

2
W1

1-4-4
1
B1

3-8
5
4
2x4
10-8 3-9-5 1-0-11
4-10-0
3-9-5

TOTAL WEIGHT = 14 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 415 0 415 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 154 0 154 0 0 1-8 1-8 DL = 7.4 PSF
4 38 0 42 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 290 209 / 0 0/0 0/0 0/0 81 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 106 89 / 0 0/0 0/0 0/0 17 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 30 0/0 0/0 0/0 0/0 30 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5, 3 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.02")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.20/1.00 (2-3:1) , BC=0.09/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.15/1.00 (2-3:1)
5- 2 -363 / 0 0.0 0.0 0.07 (8) 7.81
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -34 / 0 -109.0 -109.0 0.20 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.09 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.26 (2) (INPUT = 0.90 )


JSI METAL= 0.19 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG2 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:55 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-vLL7pdlAGYG5_F1tSJ_YUrGfGvUVCYQpPiwg0Gz606g
10-8 2-8-8 2-1-8
Scale = 1:30.9
3

10.75 12

T1

3-9-6
2x4

W1

1-4-4
1

B1

3-8
5
4
2x4
10-8 2-8-8 2-1-8
4-10-0
2-8-8

TOTAL WEIGHT = 12 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 342 0 342 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 111 0 111 0 0 1-8 1-8 DL = 7.4 PSF
4 38 0 42 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 240 167 / 0 0/0 0/0 0/0 73 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 76 64 / 0 0/0 0/0 0/0 12 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 30 0/0 0/0 0/0 0/0 30 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5, 3 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.02")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.10/1.00 (2-3:1) , BC=0.09/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.11/1.00 (2-3:1)
5- 2 -290 / 0 0.0 0.0 0.07 (8) 7.81
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -24 / 0 -109.0 -109.0 0.10 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.09 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.21 (2) (INPUT = 0.90 )


JSI METAL= 0.15 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG3 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:55 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-vLL7pdlAGYG5_F1tSJ_YUrGfivUVCYQpPiwg0Gz606g
10-8 1-7-10 3-2-6
Scale: 1/2"=1'
3

10.75 12

2x4
T1

2-9-14
2

W1

1-4-4
1

B1

3-8
5

2x4 4
10-8 1-7-10 3-2-6
4-10-0
1-7-10

TOTAL WEIGHT = 11 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 268 0 268 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 68 0 68 0 0 1-8 1-8 DL = 7.4 PSF
4 38 0 42 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 190 125 / 0 0/0 0/0 0/0 65 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 46 39 / 0 0/0 0/0 0/0 7/0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 30 0/0 0/0 0/0 0/0 30 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5, 3 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.02")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.08/1.00 (1-2:1) , BC=0.09/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.07/1.00 (4-5:8)
5- 2 -217 / 0 0.0 0.0 0.07 (8) 7.81
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -14 / 0 -109.0 -109.0 0.04 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.09 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.15 (2) (INPUT = 0.90 )


JSI METAL= 0.12 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG4 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:56 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-NXvV0zlo0sOycPc301Vn13ppPJqhx?gydMgDYiz606f
10-8 6-13 4-3-3
Scale = 1:17.3
3

2x4
10.75 12

T1

1-10-6
W1
1-4-4 1

B1

3-8
5

2x4 4
10-8 6-13 4-3-3
4-10-0
6-13

TOTAL WEIGHT = 9 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M][F]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 218 0 218 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 2 0 51 0 0 1-8 1-8 DL = 7.4 PSF
4 37 0 43 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 149 126 / 0 0/0 0/0 0/0 23 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 8 0 / -29 0/0 0/0 0/0 37 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 30 0 / -1 0/0 0/0 0/0 31 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5, 3 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.02")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.08/1.00 (2-5:8) , BC=0.09/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.07/1.00 (4-5:8)
5- 2 -166 / 25 0.0 0.0 0.08 (8) 7.81
1- 2 0 / 35 -109.0 -109.0 0.08 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -19 / 31 -109.0 -109.0 0.06 (8) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.09 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.12 (2) (INPUT = 0.90 )


JSI METAL= 0.09 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG5 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:56 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-NXvV0zlo0sOycPc301Vn13pdIJrux?gydMgDYiz606f
10-8 2-0-0 6-4-0
Scale = 1:39.4
3

4-10
5.75 12

4-11-3

4-11-3
T1

4-6-9
2x4
2
1 W1

11-4
B1

5 2x4 4
10-8 2-0-0 6-4-0
2-0-0
2-0-0

TOTAL WEIGHT = 15 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY 2100F 1.8E SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 691 0 691 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 341 0 341 0 0 1-8 1-8 DL = 7.4 PSF
4 16 0 18 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 475 385 / 0 0/0 0/0 0/0 90 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 233 196 / 0 0/0 0/0 0/0 37 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 13 0/0 0/0 0/0 0/0 13 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.00")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.85/1.00 (2-3:1) , BC=0.02/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.40/1.00 (2-3:1)
5- 2 -670 / 0 0.0 0.0 0.01 (8) 7.81
1- 2 0 / 22 -109.0 -109.0 0.04 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -49 / 0 -109.0 -109.0 0.85 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.02 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.37 (2) (INPUT = 0.90 )


JSI METAL= 0.27 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JG6 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:57 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-rjTuEJmQn9WoDZBGZk00aGMvGjB7gSw5s0Pn49z606e
10-8 2-0-0 2-7-2
Scale = 1:26.4
3

4-10
5.75 12

T1

3-1-11

3-1-11
2-9-1
2x4

1 W1

11-4
B1

5
4
2x4
10-8 2-0-0 2-7-2
2-0-0
2-0-0

TOTAL WEIGHT = 10 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 436 0 436 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 188 0 188 0 0 1-8 1-8 DL = 7.4 PSF
4 16 0 18 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 301 239 / 0 0/0 0/0 0/0 62 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 129 108 / 0 0/0 0/0 0/0 21 / 0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 13 0/0 0/0 0/0 0/0 13 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 6.25 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (8) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.00")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.39/1.00 (2-3:1) , BC=0.02/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.22/1.00 (2-3:1)
5- 2 -415 / 0 0.0 0.0 0.01 (8) 7.81
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -27 / 0 -109.0 -109.0 0.39 (1) 6.25 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.02 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.23 (2) (INPUT = 0.90 )


JSI METAL= 0.17 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JGG1 1 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:57 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-rjTuEJmQn9WoDZBGZk00aGMrPj56gKu5s0Pn49z606e
4-10-0
4x6 Scale = 1:44.0
2

12

1-
1-

12
10.75 12

T1

5-8-3
W1
W2
4x6

W4

1-4-4

4-4
1-
W3

8
B1

4
5 3
6x8
2x4 4-10-0 2x4
2-5-0 2-5-0
4-10-0

TOTAL WEIGHT = 29 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
3 - 2 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 1 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 - 3 2x6 DRY No.2 SPF 3 2288 0 2288 0 0 MECHANICAL BOT CH. LL = 0.0 PSF
5 2288 0 2288 0 0 5-8 3-15 DL = 7.4 PSF
ALL WEBS 2x3 DRY No.2 SPF TOTAL LOAD = 44.7 PSF
EXCEPT A SUITABLE HANGER/MECHANICAL CONNECTION IS REQUIRED AT JOINT 3. MINIMUM BEARING
LENGTH AT JOINT 3 = 3-15. SPACING = 24.0 IN. C/C
DRY: SEASONED LUMBER.
GIRDER TYPE: CStdGirder
START DISTANCE = 0-0
UNFACTORED REACTIONS START SPAN CARRIED = 28-0-0
1ST LCASE MAX./MIN. COMPONENT REACTIONS END DISTANCE = 4-10-0
PLATES (table is in inches) JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL END SPAN CARRIED = 28-0-0
JT TYPE PLATES W LEN Y X 3 1606 1125 / 0 0/0 0/0 0/0 481 / 0 0/0 END WALL WIDTH = 3-8
1 TMVW-t MT20 4.0 6.0 1.50 Edge 5 1606 1125 / 0 0/0 0/0 0/0 481 / 0 0/0 APPLIED TO FRONT SIDE OF BOTTOM CHORD.
2 TMVW-t MT20 4.0 6.0 1.75 1.75 - ADDT'L LOADS BASED ON 55 % OF GSL.
3 BMV1+p MT20 2.0 4.0 BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5
4 BMWW+t MT20 6.0 8.0 4.25 3.00 THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
5 BMV1+p MT20 2.0 4.0 BRACING SMALL BUILDING REQUIREMENTS OF PART 9,
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 5.02 FT. NBCC 2015
Edge - INDICATES REFERENCE CORNER OF PLATE MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
TOUCHES EDGE OF CHORD. THIS DESIGN COMPLIES WITH:
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. - PART 9 OF BCBC 2018 , NBC-2019AE
- PART 9 OF OBC 2012 (2019 AMENDMENT)
LOADING - CSA 086-14
TOTAL LOAD CASES: (8) - TPIC 2014

CHORDS WEBS (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
MAX. FACTORED FACTORED MAX. FACTORED LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX LIVE LOAD
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC)
FR-TO FROM TO LENGTH FR-TO ALLOWABLE DEFL.(LL)= L/360 (0.19")
1- 2 -1207 / 0 -109.0 -109.0 0.56 (1) 5.02 4- 2 0 / 2078 0.51 (1) CALCULATED VERT. DEFL.(LL) = L/ 999 (0.02")
3- 2 -1332 / 0 0.0 0.0 0.70 (1) 6.98 1- 4 0 / 969 0.24 (1) ALLOWABLE DEFL.(TL)= L/360 (0.19")
5- 1 -1430 / 0 0.0 0.0 0.16 (1) 6.79 CALCULATED VERT. DEFL.(TL) = L/ 999 (0.04")

5- 4 0/0 -837.9 -837.9 0.32 (1) 10.00 CSI: TC=0.70/1.00 (2-3:1) , BC=0.40/1.00 (3-4:1) ,
4- 3 0/0 -837.9 -837.9 0.40 (1) 10.00 WB=0.51/1.00 (2-4:1) , SSI=0.77/1.00 (3-4:1)

DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.00


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING COMP=1.00 SHEAR=1.00 TENS= 1.00
AS PER NBCC 4.1.6.2.(8)
COMPANION LIVE LOAD FACTOR = 1.00

TRUSS PLATE MANUFACTURER IS NOT


RESPONSIBLE FOR QUALITY CONTROL IN THE
TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.84 (2) (INPUT = 0.90 )


JSI METAL= 0.34 (4) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A JK 6 1 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:57 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-rjTuEJmQn9WoDZBGZk00aGM_JjBDgSw5s0Pn49z606e
10-8 1-7-0
Scale: 3/4"=1'
3
5.75 12

2x4

2 T1

1-8-6

1-8-6
1-3-12
1
W1

11-4
B1

4
2x4
10-8 1-7-0
1-7-0
1-7-0

TOTAL WEIGHT = 6 X 6 = 34 lb
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
5 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
1 - 3 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
5 - 4 2x4 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
5 226 0 226 0 0 5-8 1-8 BOT CH. LL = 0.0 PSF
DRY: SEASONED LUMBER. 3 65 0 65 0 0 1-8 1-8 DL = 7.4 PSF
4 13 0 15 0 0 1-8 1-8 TOTAL LOAD = 44.7 PSF

SPACING = 24.0 IN. C/C


SEE MITEK STANDARD DETAIL MSD2015-H FOR CONNECTION TO JOINT(S) 3 , 4
PLATES (table is in inches) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
JT TYPE PLATES W LEN Y X UNFACTORED REACTIONS SMALL BUILDING REQUIREMENTS OF PART 9,
2 TMV+p MT20 2.0 4.0 1ST LCASE MAX./MIN. COMPONENT REACTIONS NBCC 2015
5 BMV1+p MT20 2.0 4.0 JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
5 156 120 / 0 0/0 0/0 0/0 36 / 0 0/0 THIS DESIGN COMPLIES WITH:
3 45 38 / 0 0/0 0/0 0/0 7/0 0/0 - PART 9 OF BCBC 2018 , NBC-2019AE
4 10 0/0 0/0 0/0 0/0 10 / 0 0/0 - PART 9 OF OBC 2012 (2019 AMENDMENT)
- CSA 086-14
BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 5 - TPIC 2014

BRACING DESIGN ASSUMPTIONS


TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 10.00 FT. -OVERHANG NOT TO BE ALTERED OR CUT OFF.
MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED.
(55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
LIVE LOAD
LOADING
TOTAL LOAD CASES: (9) ALLOWABLE DEFL.(LL)= L/360 (0.19")
CALCULATED VERT. DEFL.(LL) = L/ 999 (0.00")
CHORDS WEBS ALLOWABLE DEFL.(TL)= L/360 (0.19")
MAX. FACTORED FACTORED MAX. FACTORED CALCULATED VERT. DEFL.(TL) = L/ 999 (0.00")
MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX
(LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) CSI: TC=0.07/1.00 (1-2:1) , BC=0.01/1.00 (4-5:8) ,
FR-TO FROM TO LENGTH FR-TO WB=0.00/1.00 (n/a:0) , SSI=0.08/1.00 (2-3:1)
5- 2 -209 / 0 0.0 0.0 0.01 (8) 7.81
1- 2 0 / 22 -109.0 -109.0 0.07 (1) 10.00 DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10
2- 3 -9 / 0 -109.0 -109.0 0.05 (1) 10.00 COMP=1.10 SHEAR=1.10 TENS= 1.10

5- 4 0/0 -18.5 -18.5 0.01 (8) 10.00 COMPANION LIVE LOAD FACTOR = 1.00

AUTOSOLVE RIGHT HEEL ONLY


TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING
AS PER NBCC 4.1.6.2.(8) TRUSS PLATE MANUFACTURER IS NOT
RESPONSIBLE FOR QUALITY CONTROL IN THE
CANTILEVER ANALYSIS HAS BEEN CONSIDERED IN THIS DESIGN TRUSS MANUFACTURING PLANT .

NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.12 (2) (INPUT = 0.90 )


JSI METAL= 0.08 (2) (INPUT = 1.00 )

2023-06-15
JOB NAME TRUSS NAME QUANTITY PLY JOB DESC. ROOF DRWG NO.

09604A KG1 1 3 TRUSS DESC.


TRS Components Ltd., Thorndale, ON, wor Version 8.630 S Apr 6 2023 MiTek Industries, Inc. Thu Jun 15 15:21:58 2023 Page 1
ID:_PcnZJpdZjN?Lz_t7EO0uazRByf-Jw1GRfn2YTefrjmS7SXF6Uu486K_Pi8F5g9Kcbz606d
4-9 3-6-12 3-6-12 3-9-4
10.75 12 Scale = 1:18.6
3x4
5x10 2x4 4x10
2 3 4 5
2x4 5-12 T2 3-4
1
T1

2-0

1-12
W1 W3 W4 W5 W4 W6 W7
1-8-6

W2
1-4-4

1-12

3-4

3-4
B1
1-12
4-8 2-4

9 8 7 6x8
6x10 Provide a 20" long 2x8 vertical scab at
joint 6, two sides, nailed to chord with 4 6
4x4 rows of 3" common nails @ 3" o/c, (30 2x4
nails min) 1-6 bearing.
11-3-6
3-11-6 3-6-12 3-9-4
11-3-6

TOTAL WEIGHT = 3 X 49 = 147 lb


***BEARING UNDERSIZED: 6***
LUMBER DIMENSIONS, SUPPORTS AND LOADINGS SPECIFIED BY FABRICATOR TO BE VERIFIED BY [M]
N. L. G. A. RULES BUILDING DESIGNER DESIGN CRITERIA
CHORDS SIZE LUMBER DESCR. BEARINGS
1 - 2 2x4 DRY No.2 SPF FACTORED MAXIMUM FACTORED INPUT REQRD SPECIFIED LOADS:
2 - 5 2x4 DRY No.2 SPF GROSS REACTION GROSS REACTION BRG BRG TOP CH. LL = 31.3 PSF
6 - 5 2x6 DRY No.2 SPF JT VERT HORZ DOWN HORZ UPLIFT IN-SX IN-SX DL = 6.0 PSF
9 - 1 2x4 DRY No.2 SPF 6 7537 0 7537 0 0 1-6 2-12 BOT CH. LL = 0.0 PSF
9 - 6 2x6 DRY No.2 SPF 9 7537 0 7537 0 0 5-8 2-12 DL = 7.4 PSF
TOTAL LOAD = 44.7 PSF
ALL WEBS 2x3 DRY No.2 SPF
EXCEPT UNFACTORED REACTIONS SPACING = 24.0 IN. C/C
7 - 5 2x4 DRY No.2 SPF 1ST LCASE MAX./MIN. COMPONENT REACTIONS
2 - 8 2x4 DRY No.2 SPF JT COMBINED SNOW LIVE PERM.LIVE WIND DEAD SOIL
6 5289 3704 / 0 0/0 0/0 0/0 1585 / 0 0/0 LOADING IN FLAT SECTION BASED ON A SLOPE
DRY: SEASONED LUMBER. 9 5289 3704 / 0 0/0 0/0 0/0 1585 / 0 0/0 OF 6.00/12

DESIGN CONSISTS OF 3 TRUSSES BUILT BEARING MATERIAL TO BE SPF NO.2 OR BETTER AT JOINT(S) 6, 9 GIRDER TYPE: CStdGirder
SEPARATELY THEN FASTENED TOGETHER AS START DISTANCE = 0-0
FOLLOWS: BRACING START SPAN CARRIED = 40-0-8
TOP CHORD TO BE SHEATHED OR MAX. PURLIN SPACING = 2.83 FT. END DISTANCE = 11-3-6
CHORDS #ROWS SURFACE LOAD(PLF) MAX. UNBRACED BOTTOM CHORD LENGTH = 10.00 FT OR RIGID CEILING DIRECTLY APPLIED. END SPAN CARRIED = 40-0-8
SPACING (IN) END WALL WIDTH = 1-6
TOP CHORDS : (0.144"X3") NAILS ALL PITCH BREAKS AND PERIMETER CORNER JOINTS MUST BE LATERALLY RESTRAINED. APPLIED TO FRONT SIDE OF BOTTOM CHORD.
1- 2 1 12 TOP - ADDT'L LOADS BASED ON 55 % OF GSL.
2- 5 1 12 TOP LOADING
9- 1 1 12 TOP TOTAL LOAD CASES: (8) THIS TRUSS IS DESIGNED FOR RESIDENTIAL OR
5- 6 2 12 TOP SMALL BUILDING REQUIREMENTS OF PART 9,
BOTTOM CHORDS : (0.144"X3") NAILS CHORDS WEBS NBCC 2015
9- 6 3 6 SIDE(805.9) MAX. FACTORED FACTORED MAX. FACTORED
WEBS : (0.144"X3") NAILS MEMB. FORCE VERT. LOAD LC1 MAX MAX. MEMB. FORCE MAX THIS DESIGN COMPLIES WITH:
2x3 1 6 (LBS) (PLF) CSI (LC) UNBRAC (LBS) CSI (LC) - PART 9 OF BCBC 2018 , NBC-2019AE
2x4 1 6 FR-TO FROM TO LENGTH FR-TO - PART 9 OF OBC 2012 (2019 AMENDMENT)
1- 2 0/0 -109.0 -109.0 0.00 (1) 10.00 8- 3 -215 / 135 0.01 (3) - CSA 086-14
STAGGER NAILS BY HALF THE SURFACE SPACING IN 2- 3 -15006 / 0 -109.0 -109.0 0.42 (1) 2.86 8- 4 0 / 333 0.02 (1) - TPIC 2014
ADJACENT PLIES. 3- 4 -15005 / 0 -109.0 -109.0 0.45 (1) 2.83 7- 4 -505 / 0 0.02 (1)
4- 5 -14693 / 0 -109.0 -109.0 0.41 (1) 2.91 7- 5 0 / 15568 0.83 (1) (55 % OF 41.8 P.S.F. G.S.L. PLUS 8.4 P.S.F. RAIN
TOP - COMPONENTS ARE LOADED FROM THE TOP AND 6- 5 -5381 / 0 0.0 0.0 0.12 (1) 7.44 2- 8 0 / 14319 0.77 (3) LOAD) EQUALS 31.3 P.S.F. SPECIFIED ROOF
MUST BE PLACED ON TOP EDGE OF ALL PLIES FOR 9- 1 -21 / 0 0.0 0.0 0.00 (1) 7.81 9- 2 -5487 / 0 0.26 (1) LIVE LOAD
THE LOAD TO BE TRANSFERRED TO EACH PLY.
9- 8 0 / 1550 -1227.3-1227.3 0.52 (1) 10.00 ALLOWABLE DEFL.(LL)= L/360 (0.38")
SIDE - PLF SHOWN IS THE EQUIVALENT UDL APPLIED 8- 7 0 / 14693 -1227.3-1227.3 0.87 (1) 10.00 CALCULATED VERT. DEFL.(LL) = L/ 951 (0.14")
TO ONE SIDE THAT THE CORRESPONDING NAILING 7- 6 0/0 -1227.3-1227.3 0.42 (1) 10.00 ALLOWABLE DEFL.(TL)= L/360 (0.38")
PATTERN SHALL BE CAPABLE OF TRANSFERING. CALCULATED VERT. DEFL.(TL) = L/ 540 (0.25")
REMAINING PLF MUST BE APPLIED ON THE OPPOSITE
SIDE OR ON THE TOP. TRUSS HAS BEEN CHECKED FOR UNBALANCED LOADING CSI: TC=0.45/1.00 (3-4:1) , BC=0.87/1.00 (7-8:1) ,
AS PER NBCC 4.1.6.2.(8) WB=0.83/1.00 (5-7:1) , SSI=0.52/1.00 (8-9:2)

PLATES (table is in inches) DOL LUMBER=1.00 NAIL=1.00 LS BEND=1.10


JT TYPE PLATES W LEN Y X COMP=1.10 SHEAR=1.10 TENS= 1.10
1 TMV+p MT20 2.0 4.0
2 TTWW-l MT20 5.0 10.0 2.00 5.75 COMPANION LIVE LOAD FACTOR = 1.00
3 TMW+w MT20 2.0 4.0
4 TMWW-t MT20 3.0 4.0
5 TMVW-t MT20 4.0 10.0 1.75 3.25 TRUSS PLATE MANUFACTURER IS NOT
6 BMV1+p MT20 2.0 4.0 RESPONSIBLE FOR QUALITY CONTROL IN THE
7 BMWW-t MT20 6.0 8.0 3.25 2.25 TRUSS MANUFACTURING PLANT .
8 BMWWW-t MT20 6.0 10.0 3.25 4.50
9 BMVW1-t MT20 4.0 4.0 1.75 1.75 NAIL VALUES
PLATE GRIP(DRY) SHEAR SECTION
(PSI) (PLI) (PLI)
MAX MIN MAX MIN MAX MIN
MT20 650 371 1747 788 1987 1873

PLATE PLACEMENT TOL. = 0.250 inches

PLATE ROTATION TOL. = 5.0 Deg.

JSI GRIP= 0.90 (7) (INPUT = 0.90 )


JSI METAL= 0.83 (7) (INPUT = 1.00 )

2023-06-15
Truss Hangers – THDS26

A
Materials: See chart
Finish: G90 galvanizing
Codes: CCMC 12885-R
Installation: H
• Use all specified fasteners. See Product Notes, page 10.

D
W
THDS26 Typical THDS26

© Copyright 2013 USP Structural Connectors®


installation
Dimensions (in) Application4 Fastener Schedule5,6 Factored Resistance
Header Joist2 S-P-F (Lbs) S-P-F (kN)
USP Steel Vertical Uplift1 Vertical Uplift1
Stock No. Ref. No. Gauge W H D A Header Joist3 Qty Type Qty Type 100% 115% 100% 115%
(1) 2x6 S-P-F 2x6 S-P-F 18 16d x 2-1/2 10 10d x 1-1/2 2105 1605 9.36 7.14
(2) 2x6 S-P-F 2x6 S-P-F 18 16d x 2-1/2 10 10d x 1-1/2 2330 1605 10.36 7.14
THDS26 -- -- 18 1-5/8 5-1/8 3-1/2 2-7/16
(1) 2x6 S-P-F S-P-F plated truss 18 16d x 2-1/2 10 10d x 1-1/2 3405 1605 15.15 7.14
(2) 2x6 S-P-F S-P-F plated truss 18 16d x 2-1/2 10 10d x 1-1/2 3630 1605 16.15 7.14
1) Calculated using nail resistance values in CSA O86.1-94. Nails considered to be equivalent to toe-nails to end distance.
Uplift values have been increased by 1.15 for short-term loading such as wind.
2) When used in a truss application, the fasteners into the supported member will need to be driven through the truss plate to complete the installation.
 !#!$"" #"#&# (##"$!$"%$"! ' "#
Plated Truss

4) Supporting and supported wood members are to be designed by others. Ensure supporting member can accept all fasteners.
5) Minimum nail embedment shall be 8 nail diameters (typ.).
6) NAILS:' ("! (' ( "! ('  (
New products or updated product information are designated in red font.

Heavy-Duty Truss Hangers – THDH series


Materials: 12 gauge
Finish: G90 galvanizing
Options: See Specialty Options Chart.
THDH412 is available in Triple Zinc.
To order, add TZ to stock number,
as in THDH412-TZ. Drive joist nails into header at 30° Typical THDH double
Codes: Load values are derived from data to 45° to achieve listed loads. shear installation
submitted to various North American
building code evaluators.
2 1/2˝
Installation:
• Use all specified fasteners. See Product Notes, H
page 10.
• Joist nails must be driven in at a 30° to 45° angle
through the joist or truss into the header to achieve W 4˝
listed loads. Standard length “double shear” nails
must be used to achieve listed load values. THDH Typical THDH26-2
installation
See EWP applications page 122
Some model designs
Specialty Options Chart – refer to Specialty Options pages 210 to 211 may vary from
for additional details. illustration shown

Option Skewed1,3 Sloped Seat2,3 Sloped / Skewed1,2,3


Range 4-( 4 4-( 4 %()-'$0
2 1/2˝
Dimple allows
Factored (-%/%.  (-%/%. 30˚ to 45˚
(-%/%.
Resistance  (-%.)%"-/%.  (-%.)%"-/%. nailing
' %+*."+ ,%()+*."+
'+" !-(+%-
H
'.)(+(0' %()-'$0
Ordering
-()+(.-'.&+ -()+(.-'.&+ 1   
1   1  
W D
 $0!' +,0"-!,$0, +-+-!' 3%02,!/%%#(",-'"%"' ('(',"(-!(.-,"%' 
 %()(+,%(),$0!' +,0"-!,%(), +-+-!' 3&2!/"-"('%#(",-'"%,
 %%,%(),$0(+(&"'-"(',+*."+/%.-('#(",-"'%%))%"-"(', THDH26-2
Inverted flange option is not available for THDH models.

continued on next page


166 1-800-328-5934 • www.USPconnectors.com
Handling, Erection and
Bracing of Wood Trusses
Follow these guidelines for safe installation of Wood Trusses.

These guidelines should not be considered to be the only method for erecting and bracing of a roof
system. TPIC disclaims any responsibility for damages arising from the use, application or reliance on
these guidelines.

1. Check Trusses, while they are on the ground.


a) Count trusses to ensure that you have the correct number for the job.
b) Measure trusses for the correct pitch, span and any special details.
c) Check for damage, broken members, loose plates, etc.

2. Erection Procedure,
a) Mark the bearing plates on both walls to the required spacing of trusses,
(Normally 24” O/C).
b) Hoist the trusses to the roof level, taking care not to bend or twist the trusses.
c) If interior walls are available, trusses may be laid flat.
d) If no partitions exist, trusses shorter than 32’ may be inverted and hung from the bearing
plates.
e) Erect Gable or End trusses and install braces to prevent lateral movement,
(See Figure below).
f) Run a string from heel to heel of the end trusses to be used as a guide line.
g) Erect trusses using string to locate heels. Brace each truss as it is erected.
h) Trusses may be marked at one end. Place trusses so that all marked ends are on the same
side of the building.
i) When flat trusses are used, ensure that they are installed with the proper side up.
j) Install temporary bracing with sufficient X-bracing to prevent trusses from buckling
or toppling over. Install permanent bracing.
k) Complete roof by installing roof decking, gable end ladders, etc.

Always provide horizontal restraint for the Top Chords

1
3. Handling Recommendations
Trusses must be in the vertical plane to take advantage of their superior ability to support loads.

The truss erector or the builde r shall take the necessary precautions to ensure that erection
procedures and handling methods do not damage the trusses and thus reduce their load
carrying capacity.

4. Mechanical Handling
Ideally when mechanical means are used, the trusses should be lifted in banded sets and lowered
onto supports.
When this method is used, extreme caution must be exercised when breaking the metal
straps. Trusses may domino, lose lateral stability, or totally collapse, if temporary braces
and supports are not in place before releasing the banding.

Lifting trusses singly should be avoided, but if necessary an appropriate spreader bar should be
used with slings of sufficient strength and placed in a “toed-in” position. The “toed-in” position
will prevent the truss from folding.

If erectors have any doubt, contact the truss supplier immediately.

For spans of 20 feet or less, a single pick up point may be used to lift the truss. A tag line should be used
whenever a truss is lifted to avoid having it swing and do damage.

2
Trusses up to 30 feet in length should be lifted using two pick up points located so that the distance
between them is approximately one-half the length of the truss. The angle between the two cables should
be 60 degrees or less to reduce the tendency for the truss to buckle laterally during the lift. A tag line
should be fastened to one end to prevent the truss from swinging and causing damage to other parts of the
work or to the truss itself.

A spreader bar and short cable slings should be used to lift trusses in the 30 to 60 foot range. The cable
slings may be vertical but it is recommended that they be “toed-in” to prevent the truss from folding
during the lift. Two tag lines should be used to control the raining of trusses of this size.

Trusses above 60 feet in length should be lifted with a strongback 2/3 to 3/4 the length of the truss. The
truss should be securely tied to it at 10 foot intervals or less. For flat trusses, the strongback should be tied
to the top chord. Pitched trusses should be positioned high enough on the strongback to prevent
overturning of the truss. Two tag lines should be used to control the truss during lifting.

3
5. Vertical and Lateral Alignment
ALL TRUSSES ARE LATERALLY UNSTABLE until properly braced. The longer the span the more
care required. Adequate restraint is necessary at all stages of construction.

COMPLETE STABILITY is not achieved until the bracing and decking is completely installed and
properly fastened.

ERECTION, BRACING AND PROCEDURES as well as the safety of the workers are the
responsibility of the erector.

PROBLEMS MAY OCCUR in attempts to realign trusses. Align each truss and place it permanently in
position before it is connected to the bracing system. Once there is a load, even from the weight of the
truss itself, large lateral forces are developed by attempts to realign the trusses. This may break the
bracing system.

When properly aligned, each top chord should


not vary more than 1/2 inch from a straight line. Out-of-plumb installation tolerances

4
THE BRACING SYSTEM should provide COLLAPSE CAN EASILY OCCUR without
support at spacings at no farther apart than a bracing system that will prevent both horizontal
the drawings show for the bridging. Without sway (pictured to the left) or roll over (pictured
proper bracing trusses may not support even above). By rolling on their sides, where they
their own weight. have no strength, the trusses will break or pull the
ends off the bearings.

DO NOT permit cutting, drilling or any procedure that may damage the chords or webs.

DO NOT remove webs (even temorarily).

DO NOT make field repairs to damaged trusses without the approval of the manufacturer.

DO NOT overload single or groups of trusses with plywood, roofing or other construction materials or
tools.

DO NOT erect damaged trusses. Should a truss or group of trusses fall to the ground or be damaged what
so ever, do not proceed! Thesite engineer of note must certify that the trusses are satisfactory to erect.
Notify the truss supplier immediately.

6. Temporary Gable End and Top Chord Bracing

Flat Roof Temporary Bracing Pitched Roof Temporary Bracing


5
7. Laminating Girders
All girder trusses that require laminating; two plys or more, must be laminated according to the
instructions on the truss design drawings or as per Appendix B, Tables B.1.1, B.1.2, B.1.3, B.1.4 and
B.1.5 of TPIC Truss Design Procedures manual.

8. Permanent Bracing Specified by the Building Designer


Permanent bracing is designed and specified for the structural safety of the building. It is the
responsibility of the building designer or an authority other than the truss designer to indicate size,
location and attachments for all permanent bracing. Typical applications of permanent bracing to be
specified by the building designer are as follows:

a) Top chord bracing:


If purlins are used, it is recommended that diagonal bracing be applied to the underside of
the top chord as shown below.

6
b) Bottom chord bracing:
This lateral and diagonal bracing is required to maintain the proper truss spacing and to
transfer force due to lateral forces into the side walls, shear walls or other resisting
structural elements.

7
c) Diagonal web bracing:
The diagonal web bracing specified by the building designer is used to hold the trusses in a
vertical position, to maintain the proper spacing, to distribute unequal loading to adjacent
trusses and to transfer lateral forces to the diaphragms and shear walls.

d) Anchoring of permanent lateral web bracing:


Permanent lateral bracing similar to that described in Section 9 must be anchored. It is the
responsibility of the building designer to specify the type of anchor. A typical method of
anchoring the permanent lateral web bracing is illustrated below.

8
9. Permanent Lateral Bracing Specified by the Truss Designer

a) All permanent lateral bracing shown on the truss design drawing must be of the size and
grade as specified and must be fastened at the locations shown using the number and size
of nails as specified on the truss design drawing.

b) Lateral movement of the lateral bracing shall be restrained by permanently installing cross
bracing (as shown in Section 8d) at the ends of each truss run and at intervals not
exceeding 20 feet or as shown on the structural drawings.

c) If it is not possible to install permanent lateral web bracing as specified on the truss design
drawing or if the truss run is less than three trusses of the same kind, a “T” brace shall be
installed as per the truss design drawing or Appendix C, Table C.1.1, of the TPIC Truss
Design Procedures manual.

10. Top Chord Sheathing Plane

a) If plywood sheathing is used, it must be applied with staggered joints and adequate
nailing.
b) If purlins are used, spacing should not exceed the design buckling length of the top chord
and should be adequately attached to the top chord.
c) If Valley Sets, Conventional Framing, Piggyback Trusses, etc., are installed on top of
the main trusses, the full length of the top chords of these trusses must be restrained by
sheathing or purlins spaced as specified on the structural or truss design drawings. Top
chords of trusses must always be restrained from lateral movement.

9
RECOMMENDATIONS
While the recommendations for handling, erection and bracing contained herein are technically sound, it is not
intended that they be considered the only method for erecting and bracing of a roof system. Neither should these
recommendations be interpreted as superior to or a standard.

These recommendations originate from the collective experience of leading technical personnel in the wood truss
industry, but must, due to the nature of responsibilities involved, be presented only as a guide for the use of a
qualified building designer, builder or erection contractor. Thus, the Truss Plate Institute of Canada expressly
disclaims any responsibility for damages arising from the use, application, or reliance on the recommendations and
information contained herein be building designers or by erection contractors.
FOR A COMPLETE PROFESSIONAL JOB READ ALL PRECEEDING INSTRUCTIONS.

The Truss Plate Institute of Canada would like to acknowledge the contribution of the work done
by the Western Wood Truss Association of Alberta in the preparation of this document

10
Truss Plate Institute of Canada TPIC 2014

6.7.5 Truss bracing

6.7.5.1 General
+ , ) ! 3:%
1)& , & %2 2 + 3 / , / 4 /5) / 6 +
& " 7
+ , 8 ! G ! )
9 '
F + , . / ! /' ' ' =:% ('
/" /+ " , 7& + 9 ,
" /+ " , 7 B& + ,

+ , ) )
8 ' 3 8 0' '! " 0'

6.7.5.2 Lateral brace force for wood truss compression webs


8 "
' (E " ; '
8 ; ) G ) '
Note: !

6.7.6 Top chord bearing guidelines

6.7.6.1 Lumber-on-edge
" 3
. 0' 8 #' ! "# ; ' 8
" ; ; ; '
- ' 5
$
'

6.7.6.2 Lumber-on-flat
! " 3
. 0' 8 #' ! "# ; '8
" ;
; ' - '
5 $
'
Note: & --# 8

7. Joint Design Procedures


7.1 General
8 G $ ! @ !
% ' %3 < & '

7.1.1
8 ) *
+ , ;
+ , ; @
;

C ) (
+- ' ! ,
STANDARD DETAIL MSD2015-H
Issued: SEPTEMBER 22, 2020
Expiry: APRIL 30, 2022

TOE-NAIL CAPACITY DETAILS

LATERAL AND WITHDRAWAL RESISTANCE OF BEARING ANCHORAGE BY TOE-NAILS

Length Diameter LATERAL Resistance per nail WITHDRAWAL Resistance per nail
NAIL TYPE (Lbs.) (Lbs.)
(in) (in) SPF D. FIR SPF D. FIR
3.00 0.144 122 139 30 42
COMMON
3.25 0.144 127 144 32 45
WIRE
3.50 0.160 152 173 38 52
3.00 0.122 96 108 26 36
COMMON
3.25 0.122 97 108 28 40
SPIRAL
3.50 0.152 142 161 36 50
3.25” Gun nail 3.25 0.120 94 105 28 39
Note: If using truss with D. Fir lumber and SPF bearing plate, use tabulated SPF values in table.

Nail type: Common wire Common spiral Common wire Common spiral Gun Nail
Diameter (in.) 0.160 0.152 0.144 0.122 0.120
Length (in.) 3.50 3.50 3.00 3.00 3.25
LUMBER MAXIMUM NUMBER OF TOE-NAILS
2x4 SPF 2 2 3 3 3
2x6 SPF 4 4 4 5 5
2x4 D. FIR 2 2 2 2 2
2x6 D. FIR 3 3 3 4 4

Girder
chord

RAFTER GIRDER
TRUSS 30o

CEILING MEMBER
1/3 nail
length

Top view

Figure 1: Toe-Nailing Rafter / Ceiling Member to Girder Truss

Page 1 of 2
©2020 MiTek Canada Inc., 240 Stirling Crescent, Bradford, Ontario, L3Z 4L5 | (800) 268-3434, www.mitek.ca
STANDARD DETAIL MSD2015-H
Issued: SEPTEMBER 22, 2020
Expiry: APRIL 30, 2022

TOE-NAIL CAPACITY DETAILS

Figure 2: Toe-Nail Anchorage to Bearing Plate for Uplift

Nails are installed at a 30°


angle to vertical, through
member into bearing plate
2x6 Bearing
plate
Top view
Elevation View 30o

1/3 nail
length

2x4 Bearing
plate bearing plate
Top view
Elevation View

NOTES:

1. Rafter and ceiling members may be connected to top and bottom chords of girder truss by toe-nailing the members into
the girder chords (see fig. 1), provided the factored vertical reactions of the supported members do not exceed the
lateral resistance of the toe-nails. Mechanical connectors (hangers) are required if factored vertical reactions exceed
the toe-nail capacity, or if the connection must resist horizontal loads (loads perpendicular to the face of girder or rafter).
2. Trusses, rafters or ceiling members may be anchored to the bearing plate with toe-nails (see fig. 2), provided that the
factored uplift reactions due to wind or earthquake loads do not exceed the withdrawal resistance of the toe-nails.
Mechanical anchors (tie-downs) are required for reactions that exceed the toe-nail withdrawal capacity. Toe-nail
anchorage to bearing plates is NOT permitted if uplift reactions are generated from gravity loads (snow, floor live, dead).

3. Tabulated toe-nail resistances on page 1 are for one toe-nail. Multiply unit values by the
number of nails used in the connection. Maximum number of nails in a connection shall
not exceed the tabulated limits shown on page 1 for a given lumber size /species.
4. Nail values are based on specific gravity of G = 0.42 (SPF) and G = 0.49 (D. Fir).

5. Toe-nails shall be driven at approximately 1/3 the nail length from the edge of the
joist/truss chord and driven at an angle of 30o to the grain of the member.

6. For wind / earthquake loads, tabulated lateral resistances may be multiplied by 1.15
(KD factor). No increases are permitted for tabulated withdrawal resistances.

7. Lumber must be dry (< 19% moisture content) at the time of nail installation.

8. Nail values in this table comply with CSA O86-19, Clause 12.9.

Page 2 of 2
©2020 MiTek Canada Inc., 240 Stirling Crescent, Bradford, Ontario, L3Z 4L5 | (800) 268-3434, www.mitek.ca

You might also like