You are on page 1of 20

KALRE

ACTIVE LIGHTNING RODS

NFC 17 -102 Annex C 2011 Last version


MECHANICAL TESTING & HUMUD SULFUR TESTING & ESE TESTING
OUR MISSION & OUR VISION

We as KALRE PARATONER have started our initial R&D on lightening protection


systems in 2014 and after achieving the desired quality as per the international standards,
officially established in city of Izmir, Turkey in 2015. Completely committed to excellence
production mentality and enhanced test results have been awarded by the Ministry of
Industry of Turkey, Research and Development Department with Government Promotions.
All our products have also been tested and approved by Internationally
Accredited ICMET Labrotories according the latest version of NFC17-102 Annex-C 2011
standards.

In addition to ICMET, all our products have also been tested and approved by
Mechanical Test, Humus Test as well as ESE Tests wherein our brand has been shifted to
another category in this field. Therefore all KALRE products are being manufactured with
the CE Conformity Certificate. Developing market conditions and our customer demands
forced us to start producing grounding and fluctuation equipments in 2019. Considering the
principle of Brand Permanence depends on the Product Quality, KALRE is devoted himself
to control all processes starting from R&D, design, sample production, fileld tests and bulk
production in to fulfill the customer satisfaction.

Our mission is to follow up the latest Technologies continuously in order to become


a longterm solution partner to our customers and to supply best products.

KALRE
ACTIVE LIGHTNING RODS
1
An ESE lightning rod with an Early Streamer Emission system has as a target
anticipate it to the lightning strike, in order to protect all the rest of the area. The operating
principle is the same as a simple rod, but an additional ionization system getting cover a
greater protection radius.

Creates an upward leader farther away thanks to the extra ionization of the ESE
lightning rod, which is activated by the electromagnetic field produced by the storm.
The ESE attracts the lightning to its tip, then the down-conductors conduct the current
discharge to the grounding system keeping the entire installation protected.

This ionization, allows to the active protection, to have a greater protection radius.
With this methodology we managed to cover not only the structure but also its surroundings
or open areas

It is used in all buildings and facilities in our living area such as schools, hospitals,
factory buildings, base stations, fuel filling and sales stations, airports, stadiums,
apartments, summer residences, mosques, churches and synagogues.

KALRE
ACTIVE LIGHTNING RODS
2
KALRE
ACTIVE LIGHTNING RODS

KARLE ACTIVE LIHTNING RODS

XXX

Working principle: E.S.E (Early Streamer Emission) Our product works with the
electrical field intensity of the atmosphere. It transmits the electric currents formed under
charged, electric atmosphere conditions to the interior and ensures that the ion generator
located inside is charged with these electrical currents. The ion generator ionizes its
surroundings with fast charge and discharges in these conditions, making the atmosphere
more conductive. In this way, it receives the possible lightning discharge and transmits it to
the ground safely

3
TECHNICAL DRAWING

Material is crome 304

TYPE ALR 01 & ALR 02


Exterior material : Chrome 304
Product length : 400 mm.
Product weight : 2.150 gr.
Ion cell height : 116 mm
Ion cell diameter : Ø 145 mm
Capture tip diameter : Ø 22 mm

ALR 01 ALR 02
Leghth : 400 mm Leghth : 400 mm
Material : SS Stainless Steel Material : SS Stainless Steel
Diameter of the ionic cell : 200 mm Diameter of the ionic cell : 200 mm
Diameter of lightning conductor : 20 mm Diameter of lightning conductor : 20 mm
(Transparent-monolith) (Transparent-monolith)
Trigger : Neomidium Trigger : Neomidium
Principle of operation : PDC / PDA (E.S.E) Principle of operation : PDC / PDA (E.S.E)
Standart : N FC 17-102 Standart : N FC 17-102
(2011) Latest version (2011) Latest version
ΔT = 30 μs ΔT = 40 μs
RP (Radius protection) = 71 meter RP (Radius protection) = 84 meter
r(m) : 10 x I (N FC-17-102 Annex C) r(m) : 10 x I (N FC-17-102 Annex C)
1. Protection level 20 m Level I - 48 1. Protection level 20 m Level I - 58
2. Protection level 30 m Level II - 54 2. Protection level 30 m Level II - 65
3. Protection level 45 m Level III - 63 3. Protection level 45 m Level III - 75
4. Protection level 60 m Level IV- 71
KALRE 4. Protection level 60 m Level IV - 84
ACTIVE LIGHTNING RODS
4
TECHNICAL DRAWING

Material is crome 304

TYPE ALR 03 & ALR 04


Exterior material : Chrome 304
Product length : 610 mm.
Product weight : 4.200 gr.
Ion cell height : 145,46 mm
Ion cell diameter : Ø 195 mm
Capture tip diameter : Ø 22 mm

ALR 03 ALR 04
Leghth : 600 mm Leghth : 600 mm
Material : SS Stainless Steel Material : SS Stainless Steel
Diameter of the ionic cell : 200 mm Diameter of the ionic cell : 200 mm
Diameter of lightning conductor : 20 mm Diameter of lightning conductor : 20 mm
(Transparent-monolith) (Transparent-monolith)
Trigger : Neomidium Trigger : Neomidium
Principle of operation : PDC / PDA (E.S.E) Principle of operation : PDC / PDA (E.S.E)
Standart : N FC 17-102 Standart : N FC 17-102
(2011) Latest version (2011) Latest version
ΔT = 50 μs ΔT = 60 μs
RP (Radius protection) = 95 meter RP (Radius protection) = 107 meter
r(m) : 10 x I (N FC-17-102 Annex C) r(m) : 10 x I (N FC-17-102 Annex C)
1. Protection level 20 m Level I - 68 1. Protection level 20 m Level I - 79
2. Protection level 30 m Level II - 75 2. Protection level 30 m Level II - 86
3. Protection level 45 m Level III - 86 3. Protection level 45 m Level III - 97
4. Protection level 60 m Level IV - 95
KALRE 4. Protection level 60 m Level IV - 107
ACTIVE LIGHTNING RODS
5
TECHNICAL DRAWING

Material is crome 304

TYPE ALR 05 & ALR 06


Exterior material : Chrome 304
Product length : 610 mm.
Product weight : 4.200 gr.
Ion cell height : 123 mm
Ion cell diameter : Ø 195 mm
Capture tip diameter : Ø 22 mm

ALR 05 ALR 06
Leghth : 600 mm Leghth : 600 mm
Material : SS Stainless Steel Material : SS Stainless Steel
Diameter of the ionic cell : 200 mm Diameter of the ionic cell : 200 mm
Diameter of lightning conductor : 20 mm Diameter of lightning conductor : 20 mm
(Transparent-monolith) (Transparent-monolith)
Trigger : Neomidium Trigger : Neomidium
Principle of operation : PDC / PDA (E.S.E) Principle of operation : PDC / PDA (E.S.E)
Standart : N FC 17-102 Standart : N FC 17-102
(2011) Latest version (2011) Latest version
ΔT = 105 μs ΔT = 145 μs
RP (Radius protection) = 156 meter RP (Radius protection) = 197 meter
r(m) : 10 x I (N FC-17-102 Annex C) r(m) : 10 x I (N FC-17-102 Annex C)
1. Protection level 20 m Level I - 124 1. Protection level 20 m Level I - 164
2. Protection level 30 m Level II - 132 2. Protection level 30 m Level II - 173
3. Protection level 45 m Level III - 145 3. Protection level 45 m Level III - 186
4. Protection level 60 m Level IV - 156
KALRE 4. Protection level 60 m Level IV - 197
ACTIVE LIGHTNING RODS
6
KARLE ACTIVE LIGHTNING RODS PROTECTION RADIUS TABLE

Rp2 = h( 2D-h) + ΔL( 2D+ΔL) h≥5 m

D: Lightning progression is the step of the lightning strike along the path..

For Level I Protection D=20 m


For Level II Protection D=30 m
For Level III Protection D=45 m
For Level IV Protection D=60 m

ΔL (m): V(m/µs).ΔT(/µs) is calculated from the formula


V: It is the velocity of the ions formed around the catch tip uder lightning
conditions to the lightning and V = 1m / µsec in the standards

ΔT: It is the time that lightning rods feel the lightning


ΔL: ΔT It is the distance to capture lightning (i.e. the distance that ions go towards lightning).
h: Active lightning rod height (m))
Rp: Protection radius (m))

KALRE
ACTIVE LIGHTNING RODS
7
KALRE
ACTIVE LIGHTNING RODS
8
KALRE
LIGHTNING COUNTER

KLR 01

Striker X Lightning Event Counter


Display Model Electromechanical display (non re-settable)
Current Tested (10/350 µs) 100 kA
Start Sensitivity (8/20 µs) 1500 A
Current Sample Mode Inductive Probe (Built-in)
Indicator 6 digits
Operating temperature (oC) -20 ~ +85
Enclosure material Plastic
Degree of protection IP 67 (IEC 529)
Dimension of counter (cm) 16 (L) x 9 (W) x 6 (H)
FEATURES
• IP 67 rated enclosure suitable for external application.
• Ease of installation, Striker X can be retro-fitted to any
lightning protection system.
• Non-intrusive and fast acting proximity circuit detects
lightning transient currents.
• Non resettable electro-mechanical counter.
• Can be mounted at any location along the down conductor.

Size : 170 x 82 x 60 mm
Material : Stainless chrome (304) / PVC
Discharge measurement Power : 150 kA
Installation location : Lightning Protection Systems.
Testability : Mechanical
Standard : NF C 17-102 (2011) latest version

KALRE
ACTIVE LIGHTNING RODS
9
KALRE
LIGHTNING COUNTER

KLR 02

Desciption : Testable Lightning Strike Counter


Display Model : Electromecharical display (non resettable)
Current Tested (10/350 µs) : 100 KA
Current Sample Mode : Inductive Probe
Indicator : 6 digits
Operating temperature (°C ) : -20 ~ +90
Enclosure material : Hard Plastic
Degree of protection : IP 67 ( IEC – 529 )
Dimension of counter (cm : Yes
Grounding Bar : Various option

KALRE
ACTIVE LIGHTNING RODS
10
KALRE
ACTIVE LIGHTNING ROD TESTER

KLR 03

In the active lightning, the jump range is the test to control DT.
The purpose of this test is whether this jump interval is short-circuited when the
lightning rod is exposed to lightning current.
(To work when the electric charge in the clouds is 10-20 KV/M)if it has been
short-circuited it will not perform its function as an active lightning rod.

Use: the tester’s cable connects to the socket on the active lightning rods, the button is pressed.
if the red led is lit, the Ion Generator is malfunctioning. It can’t act as an active lightning rod.
The Green generator is solid if the green led is lit.

KALRE
ACTIVE LIGHTNING RODS
11
KALRE
LIGHTNING COUNTER TESTER

KLR 04

KALRE
ACTIVE LIGHTNING RODS
12
KALRE
SURGE ARRESTERS - VARISTOR

KLR 05
PIIIM-275/3+1 Vseries
Connection of potential - free remote monitoring

ok failure » varistor arrester type 2


» 4-pole arrester
» 3-phase power supply network TN-S, TT
» LP Z 1 -2
» Imax 50 kA
» M – spare module
» DS – remote monitor (optional)

4-pole MOV lightning arrester

PIIIM-275/3+1

TN-S TT
TYPE CLASS LPZ +80°C IP
2 II 1 2 -40°C 20 home industry

N L1 L2 L3

123
DS
PE

TN-S

3x230/400V/50Hz

KALRE
ACTIVE LIGHTNING RODS
13
KALRE
ACTIVE LIGHTNING RODS
14
Installation Equipments

Lightning Arresters and Equipments


Order Code Type Dimension Height
Ø20600CU Copper, Cr-Ni Plated Ø 20mm 60cm
Ø20800CU Copper, Cr-Ni Plated Ø 20mm 80cm
Ø16600P Stainless 304 Ø 16mm 60cm
Ø16800P Stainless 304 Ø 16mm 80cm
Customize production is available upon your needs
EYUAA Lightning Arrester Foot Plate (adjustable)
EYUAS Lightning Arrester Foot Plate (fixed)

Plastic Test Connector


Order Code Type
ETKLM Plastic covered testing connector
Conductor Clamp
Order Code Type
EDKV Screw Wall Clamp ( Single - Pairwise )
EDKL Straight Wall Clamp ( Single - Pairwise )
EDKV EÇKV Screw Roof Clamp
EPLON Plon Clamp ( For I-iron and Angle Iron )
EMK Roof Ridge Clamp ( Single - Pairwise )
EKK Roof Tile Clamp ( Single - Pairwise )
EBİK Conductor Pipe Clamp
EDKL EDT Pole Plate ( Medium – Wall – Corner )

ECKV EPLON EMK EKK EBİK EDT


Earthing Clamps
Order Code Type
ETK Earthing Clamp ( 2mm )
ETK ETK3 Earthing Clamp ( 3mm )
ETK.T Earthing Clamp Single ( 1mm )
ETK.T15 Earthing Clamp Single ( 1,5mm )
ETK.T ETK.T 2 Earthing Clamp Single ( 2mm )
Pole Lock Clamps
Order Code Type
EBTKB Pipe Lock Clamp 2-3” ( Concrete )
EBTKT Pipe Lock Clamp 2-3” ( Brick )
EBTKB EBYUTK Lock Clamp ( Fixing Pipe and Lightning Arresters ) 2-3”

EBTKT KALRE
ACTIVE LIGHTNING RODS
EBYUTK
15
Earthing Materials

Earthing Materials
Order Code Type
ESK-SS Strip Clamp strip/strip 60x60x2mm
ESK-SD Strip Clamp strip/iron 60x60x2mm
ESKB-SS Strip Clamp (Cross) strip/strip 80x80x3mm
ESKB-SD Strip Clamp (Cross) strip/iron 80x80x3mm
EPDB Potential Balance Bus Bar (tin plated) 3x30x1000mm
ETKR Earthing Clamps (carrying the strip on the wall)

ESK-SS ESK-SD ESKB ETKR


Outdoor s Bar
Earthing Bu
Order Code Type
EDTBT Outdoor Earthing Bus B ar ( Equipotential )
EDTB Outdoor Earthing Bus B ar

EDTBT EDTB

KALRE
ACTIVE LIGHTNING RODS
16
Alpek Hardwares and Fixture Consoles

Alpek Hardware Materials


Order Code Type
EOZD Stirrup Iron
EOZM Stirrup Shaft
EJ J-Hook ( for Alpek Hardwares )
EMİPL Roller Insulator Plate ( for Tensioning )
EMİZ Roller Insulator
EJ KAN J-Hook ( for Mounting Disconnectors )

ÖZM – ÖZD EJ EMİZ

EMİPL EJ KAN

Fixture Consoles
Order Code Type
SLS101 Fixture Consoles ( Wall )
SLS102 Fixture Consoles ( Column )
SLS103 Fixture Consoles ( Gooseneck 42x600x1,5mm )
SLS104 Fixture Consoles ( Gooseneck 42x600x1,2mm )
SLS105 Gooseneck Clamp Kit

SLS101 SLS103 – SLS104 SLS102

KALRE
ACTIVE LIGHTNING RODS
17
KALRE
ACTIVE LIGHTNING RODS
18
www.kalreparatoner.com
info@kalreparatoner.com
export@kalreparatoner.com
GSM: +90 533 238 07 61
1. Sanayi Sitesi 2841 Sok. No: 9 Konak İzmir Turkey

You might also like