You are on page 1of 3

Measurement of air flow 4008TAG2A

1 2 3 4 11.0 6.9 7.0 11.1

(Default = same as
Temp into after rad for 0 load
8 7 6 5 fan = 34 conditions) 10.7 7.7 7.1 9.7

Temp
after rad. HIGH
9 10 11 12 = 39 9.2 6.6 6.3 8.7

16 15 14 13 8.8 6.1 7.7 10.2

17 18 19 20 9.1 5.7 7.2 8.7


Average
(from
anemome
24 23 22 21 ter) = 8.0875 M/s 7.0 5.4 7.3 8.9
Radiator face area 2050 mm wide = input field
1590 mm high WIDE
= 3.2595 M2

Volume flow at fan = 25.9388 M3/s

Min.Air flow by technical data 4008-TAG2 22 M3/sec


1350 M3/min

Min.Air flow by technical data 4008-30TAG3 20 M3/sec


1176 M3/min