DSEULTRA
®
STARTING
WITH
QUALITY. SPECIFICATION
DC SUPPLY
CRANKING DROPOUTS
Able to survive 0V for 50mS, providing supply
was at least 10V before dropout and supply
recovers to 5V. This is achieved without the
need for internal batteries. LEDs and backlight
will not be maintained during cranking.
MAGNETIC PICKUP
VOLTAGE RANGE
0.5V RMS minimum
TESTING STANDARDS
DSE4410 & DSE4420
ELECTRICAL SAFETY/
ELECTROMAGNETIC COMPATIBILITY
TO LOAD
DSE4420 ONLY
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
L1 L1
TEMPERATURE (OPERATING)
BS EN 60068-2-2
L2 L2
Test Ab to +70oC 60067-2-2 Hot
Test Ab to -30oC 60068-2-1 Cold
FROM L3 L3
FROM
GENERATOR MAINS VIBRATION
(UTILITY) BS EN 60068-2-6
N N Ten sweeps in each of three major axes
5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn
APPROPRIATE
APPROPRIATE
MAG PICK UP VERSION ONLY
FUSE
FUSE
2 AMP FUSES
2 AMP FUSES
HUMIDITY
BS 2011 part 2.1 60068-2-30
GBCR MBCR
Test Cb Ob Cyclic
93% RH @ 40oC for 48 hours
*
MPU
SHOCK
CON 1 CON 2
DO NOT
BS EN 60068-2-27
CONNECT
THE
Three shocks in each of three major axes
SCREEN
TO ENGINE
15gn in 11mS
15 16 12 13 14 17 18 19 20
U
L1
N
+ -
GEN VOLTS MPU TESTING STANDARDS
USB
SENDER COMMON
FUEL SENDER
4 FET OUTPUTS
PLANT +VE PLANT +VE ENGINE ECU
BATTERY 6 INPUTS
BS EN 61000-6-2
-VE
+VE
1 2 3 4 5 10 11 21 22 23 24 25 26 6 7 8 9 14 12 13 Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for the
FUEL
CONNECT THE
SCREEN TO
Industrial Environment
RECOMMENDED THAT
EMERGENCY STOP BREAKS THE
FUEL AND CRANK OUTPUTS
ENGINE ONLY
USER CONFIGURABLE -VE INPUT E
WL
CHARGE
ELECTRONIC ENGINE VERSION ONLY
FUEL ALT
Hours run counter
* †
Battery volts
MBCR NOTE 2. 120 R TERMINATING RESISTOR
CRANK
MAY BE REQUIRED EXTERNALLY Fail to start/stop
SEE ENGINE MANUFACTURERS LITERATURE Emergency stop
GBCR
Failed to reach loading voltage/frequency
Charge fail
Low DC voltage
BATTERY NEGATIVE MUST BE GROUNDED NOTE 1. THESE GROUND CONNECTIONS MUST BE ON THE EN- CAN diagnostics
GINE BLOCK, AND MUST BE TO THE SENDER BODIES. Mains volts 3 phase (DSE4420 only)
TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm )
FIELD WIRING * NOTE 3. MAINS BREAKER CLOSED OUTPUT SHOULD BE AMF indications (DSE4420 only)
CONFIGURED FOR DE-ENERGISE CLOSE MAINS, AND USE THE
TIGHTENING TORQUE = 0.8Nm (7lb-in) NORMALLY CLOSED CONTACTS OF MBCR.
RELATED MATERIALS
TITLE PART NO’S
DSE4410 Manual 057-092
DSE4420 Manual 057-093
DSE Configuration Suite PC Software Manual 057-101
DSE4410 Installation Instructions 053-056
DSE4420 Installation Instructions 053-057
PENDING
DEEP SEA ELECTRONICS maintains a policy of continuous development and reserves the right to
change the details shown on this data sheet without prior notice. The contents are intended for guidance only.
This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre
from both pre and post-consumer sources, together with 45% virgin ECF fibre.
055-068/11/08 (1)