Professional Documents
Culture Documents
Vintage: 01 / 1
Engineering Center Service Handling Page: 1 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
Document Revision :
Copyright 2002, OTIS GmbH & Co. OHG Berlin. No part of this document may be copied or reproduced in
any form or by any means without the prior written consent of OTIS.
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 2 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
Table of Contents
Vintage: 01 / 1
Engineering Center Service Handling Page: 3 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
Location: Name:
Selftest ( M - 2 - 3 - <GOON>)
EEPROM PROM
Part number ( M - 2 - 4 )
Direction - Up
tcr up
tcr do xxx xxx xxx
I % %2
t
Direction - Down
tcr up xxx xxx xxx
tcr do
I % %2
t
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 4 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
Fan in use
__ : __ : __ ___ ___
3 4 5
SYS: E2P failure SYS: E2P written SYS: E2P Default
FATAL ERROR INFORMATION INFORMATION
6 7 8
SYS: E2P InvPara SYS: ParaConflkt SYS: PckgTst Err
FATAL ERROR FATAL ERROR ERROR
9 10 11
SYS: Power Fail SYS: <24V Supply SYS: <15V Supply
FATAL ERROR FATAL ERROR FATAL ERROR
12 13 14
SYS: Inv-Relay SYS: not all err not used
FATAL ERROR WARNING
15 16 17
SYS: 1LS + 2LS SYS: Int FormErr SYS: ADC Offset
FATAL ERROR FATAL ERROR FATAL ERROR
18 19 20
not used not used not used
21 22 23
INV: >Volt DC INV: >Heat Packg INV: <Volt DC
FATAL ERROR FATAL ERROR FATAL ERROR
24 25 26
INV: Pwr Section INV: >Curr IGBT not used
FATAL ERROR FATAL ERROR
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 5 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
27 28 29
INV: >Curr Motor INV: Temp meas. INV: brake chopp
FATAL ERROR ERROR FATAL ERROR
30 31 32
not used INV: Err undefnd CAN: CAN error
ERROR ERROR
33 34 35
CAN: BusOff CAN: OPB_Init CAN: TxQueueFull
ERROR FATAL_ERROR ERROR
36 37 38
CAN:1/2lsUndefnd MC:EMERGNCY ST M C:Command Lst
FATAL ERROR FATAL ERROR ERROR
39 40 41
M C: FR w/o Learn not used MC:MC + SafetyCh
ERROR FATAL ERROR
42 43 44
MC: Encodr adj? MC: OCSS disabld M C: Chk SW Sig
FATAL ERROR FATAL ERROR FATAL ERROR
45 46 47
M C: Chk DBD Sig M C: Chk RDY Sig M C: Chk BS1/BS2
FATAL ERROR FATAL ERROR FATAL ERROR
48 49 50
not used ALW:NoLoadW Cal ALW:LoadW Sensor
ERROR ERROR
51 52 53
MLS: <Acc Dist MLS: <Dec Dist MLS: Stop in LS
WARNING WARNING WARNING
54 55 56
not used MLS: Inp Error MLS: 1LS Ini Dec
ERROR WARNING
57 58 59
MLS: 2LS Ini Dec MLS: RLV-Count not used
WARNING ERROR
60 61 62
MLS: LV Missed MLS: LV lost MLS: LV Count Err
FATAL ERROR FATAL ERROR WARNING
63 64 65
MLS: LV Trig Err not used not used
WARNING
66 67 68
not used not used DRV:EncoderWarn
WARNING
69 70 71
DRV:Encoder Err not used DRV: >Speed
FATAL ERROR FATAL ERROR
72 73 74
DRV: <Speed not used DRV: Rollb Start
FATAL ERROR WARNING
75 76 77
DRV: Rollb Stop DRV: Encoder Dir DRV: MRO done
WARNING ERROR WARNING
78 79 80
DRV: Overld>Time Overload DRV: Phase Down
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 6 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
FATAL ERROR WARNING FATAL ERROR
81 82 83
DRV: I Overload not used not used
WARNING
84 85 86
not used not used LRN: Learn abort
FATAL ERROR
87 88 89
LRN: < Mag Len LRN: > Mag Len LRN: Mag Len Var
FATAL ERROR FATAL ERROR FATAL ERROR
90 91 92
LRN: <Floor Dist LRN: >Floor Dist LRN: Too many LV
FATAL ERROR FATAL ERROR FATAL ERROR
93 94 95
not used ADJ: EncAdj err ADJ: Auto-Encadj
FATAL ERROR INFORMATION
96 97 98
not logged not logged not logged
99
not logged
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 7 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
2 List of Parameters
Location: _________________________ SW-version: __________________________
Vintage: 01 / 1
Engineering Center Service Handling Page: 8 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
4 Preventive Maintenance
The preventive replacement of spare parts is supported by the Service Tool.
Status = 1 Set = 2 1 = Shows time of use of the package, capacitor bank, fan
and EEPROM
2 = Allows to change the time of use of the spare parts
Be careful when using this feature ! (see chapter 5)
↓
< GO ON >
↓
Abs No. of Runs 0000000 =absolute number
00000000 of runs
↓
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 9 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
< GO ON >
↓
↓
< GO ON >
↓
xxxxx : number of EEPROM E2P Write Cycle
write cycles xxxxx
Status = 1 Set = 2
When the lifetime of a spare part has ended, one or more messages will appear:
CHANGE ”SPAREPART”
<M> <2> <8> lifetime exceed
↓
Part: 4 - AA3
FIELD COMPONENT MANUAL
OTIS No.: GAA26800KFIII_FC1
Vintage: 01 / 1
Engineering Center Service Handling Page: 10 / 10
Berlin MCB III Date: 13-Mar-02
GeN2
< GO ON >
↓
Status = 1 Set = 2
After replacing a spare part, the usage time in the maintenance menu has to be adapted.
Caution!
These parameters should normally not be changed.
These parameters have to be written only if one of the spare parts described above
has been replaced.
↓
< GO ON >
↓
New CB Time? New capacitor bank time
Day: ddd Year: yy of use (after replacement
of defective parts)
↓
< GO ON >
↓
New Fan Time? New fan time of use
Day: ddd Year: yy (0 for new fans)