Professional Documents
Culture Documents
00 HOUSE H - DOOR WINDOW KAYU
00 HOUSE H - DOOR WINDOW KAYU
00 HOUSE H - DOOR WINDOW KAYU
A-202
1 2 3 4 5 6
19506 mm
16400 mm 3105 mm
200 mm 4000 mm 150 mm 10560 mm 300 mm 2130 mm 200 mm
1770 mm
SAUNA 200 mm
677 mm
200 mm
2320 mm
1665 mm
D -0.03
900 mm
200 872 mm
16
W
755 mm
1945 mm
SAUNA
03
900 mm
D
6550 mm
09
1330 mm
400 B
W
COLD PLUNGE
2500 mm
W 02
200 mm
18
1350 mm
1125 mm
5400 mm
MAID QUARTER
COLD PLUNGE
MAID QUARTER
800
D +0.00
855 mm
-1.00 FFE-01
08
4150 mm
A-206 950 mm 5200 mm
800 mm 800 mm 1550 mm
150 mm
150 mm
715
795 mm 2640 mm INDOOR GARDEN
Manhole 600/600 -0.10
To pump room D
LIVING R. MAID BATHROOM
10
2275
2186 mm
1500 mm
-0.20
900
-0.03
FFE-05
+0.00
FFE-06
2775
3510 mm
GARDEN 760 mm
650
200 mm
-0.20
C
384 mm
900 2200 mm
A-203
850
A-201
1800 mm
2000 mm
1000 mm
13620 mm
100
13500 mm
D FOYER
A-205 05 1100 mm
-0.10 700
550 1100 mm 3300 mm
850
4400 mm
9450 mm
700 FFE-07
200 mm
W
D
10841 mm
01
2000 mm
1700 mm
1300 mm
2358 mm
D
1300
1900 mm
-0.03 DINING R. 04
+0.00
200
150
5200 mm
200
PATIO
FFE-25
TOILET
800 mm
1000
-0.18 D
800
06 +0.00
KITCHEN 2400 mm
GARAGE
5715 mm
150
5915 mm
A-204 +0.00
3425
3025 mm
GARAGE
FFE-04
1725 mm
FFE-02 -0.18
1725 mm
STORAGE
+0.00
300
F
540
1200 mm
4162 mm FFE-03
1200 mm
D D
1170
D
03 300 600 380 07 D
02
01
630
990 mm
202 mm
200 mm
G
A-207
A-208
4300 mm 200 mm 850 mm 200
9050 mm
N
LIVING DINING 2700 mm
200 mm 6200 mm
GARDEN 4200 mm
15445 mm GARAGE 200 mm
19851 mm
A-200
© ZXC Studio KEY PROJECT PROJECT NO. DATE DRAWING NO.
1. Drawings indicate design intent only. The Contractor & relevant consultants & /or sub-contractors to ensure all current building regulations, standards, &
HOUSE T 2305 09/11/2023
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-100
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:75 @ A3 For Tender
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD.
8 the Terrace, Longshore, London
R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. GA Plan Lvl 1 N XC
SE8 3AU United Kingdom
1 2 3 4 5 6
W
16
200 mm
200 mm
A
SAUNA ROOFTOP
2100 mm
2275 mm
FFE-22
2000 mm
+2.45
GUEST BEDROOM
W
15
2950 mm
GUEST
200 500 4700 mm 3450 mm BEDROOM FFE-21
+3.15 B
4400 mm
500 200
4225 mm
5600 mm
5400 mm
6350 mm 1600 mm 2600 mm
+3.10
1760 mm
320 mm
1418 mm
975 mm 600 mm
150 mm
FFE-23 R:500 mm
1450 mm
3400 mm
1300 mm
3000 mm
FFE-20
GUEST ENSUITE
GUEST
ENSUITE
2100 mm
800 mm
+3.12
5125 mm
1000 mm
ROOF TERRACE
800 mm
FFE-19 W
4425 mm
D D
+3.13 800 540 17
14 15
200 mm
3500 mm
C
3600 mm 310 800 mm 3290 mm
12525 mm
850
2200 mm 850 mm
1800 mm
1800 mm
2000 mm
STAIRS
+3.13
850 mm 100
7750 mm 2300 mm
2800 mm 200 mm
200 mm
200 mm
D
720 mm
940
FFE-11 FFE-18
1900 mm
FFE-12
1680 mm
1900 mm
1900 mm
R:1950 mm
800 mm
MASTER BEDROOM D
800
FFE-24
7125 mm
+3.15 D 13 FFE-17
11
300 800 1700 mm
140
380
E
420
+3.12
5125 mm
4725 mm
4725 mm
STUDIO
420 mm 1290 mm 1100
W D
820
R:500 mm 1400 mm 3000 mm
11 12
1625 mm
STUDIO
2175 mm
FFE-15 +3.15
3045 mm
3025 mm
MASTER ENSUITE
2425 mm
2825 mm
FFE-13
+3.12
825
750 mm 650 mm FFE-16
800 mm
FFE-14
1000 mm
W
630
13
200
200 mm
200 mm
F
4162 mm
1200 mm
W W
990 mm
N
MASTER BEDROOM MASTER ENSUITE STUDIO
13450 mm
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-101
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:75 @ A3 For Tender
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD.
8 the Terrace, Longshore, London
R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. GA Plan Lvl 2 N XC
SE8 3AU United Kingdom
DOORS & WINDOWS
370 mm
400 mm
Steel pole
Hardwood plank
Sliding guide Powder coated
100/18mm [JF-03]
30 mm
Color match to [JF-03]
Hardwood plank
605 mm
100/18mm
575 mm
[JF-03]
60
Custom handle:
Solid Timber [JF-03]
2250 mm
2220 mm
2280 mm
2280 mm
Garage outside
1545 mm
1545 mm
Inner Frame:
steel 30/70 mm
100
-0.18
60 mm
-0.23
60
66 mm Custom handle:
Bottom rail
D-01 Section D-01 Elevation Solid Timber [JF-03]
Scale 1:25 200 mm Scale 1:25
4200 mm 200 mm
inside
100
60
4400 mm
Steel pole
200 mm Inner Frame: Powder coated
Hardwood plank 100/18mm steel 30/70 mm Color match to [JF-03]
[JF-03]
200 68
Custom handle:
Solid Timber [JF-03]
4200 mm 200 mm
outside D-01
Sliding System
Hardware
Gate bolt to side frame and to floor
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-155
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-01 Gate N XC
SE8 3AU United Kingdom
Door leaf:
Bengkirai plank
25x50 mm
40 mm
Frame: Steel hollow Frame: Steel hollow
40
Door leaf: 40x40mm [JF-11] 40x40mm [JF-11]
Bengkirai plank
25x50 mm
2400 mm
2480 mm
2380 mm
2460 mm
2460 mm
MEP Area Garage MEP Area Garden
40 mm
40
25 50 50
40 mm 911 mm 40 mm 40
25 40
991 mm 90 mm
870 mm 90 mm
90 mm
Door Leaf Bengkirai plank 25/50 Door Leaf Bengkirai plank 25/50
40
110
200
500 mm
Hardware Hardware
Lock Lock
991 mm
Garage
Garden
D-03 Plan
D-02 Plan Scale 1:25
Scale 1:25
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-160
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R!
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-02, D-03 N XC
SE8 3AU United Kingdom
Pivot hinge bolt to lintel beam
Door leaf:
Veneer Plywood [JF-01]
Door leaf:
Door handle:
Veneer Plywood [JF-01]
Solid timber natural finish
Door leaf:
Veneer Plywood [JF-01] Door handle:
Solid timber natural finish
Door handle:
2400
2200 mm
2200 mm
Solid timber natural finish
Foyer Living area
Foyer Garage
D-04 Elevation From Garage D-05 Elevation from Living Area D-05 Section
Scale 1:25
D-04 Section Scale 1:25
Scale 1:25
Scale 1:25
1000 mm
50 950
120
60
Foyer
160 80 160
400 mm
Living Area
Foyer 120
60
100 1200
D-04 D-05
200 mm
80
Door Leaf Veneer Plywood [JF-01] Door Leaf Veneer Plywood [JF-01]
Garage
Insulation fill Insulation fill
1300 mm Pivot hinge Pivot hinge
D-04 Plan D-05 Plan
Scale 1:25 Hardware Scale 1:25 Hardware
Mortice lock, key from outside Mortice lock, key from outside
thumb turn from the inside thumb turn from the inside
Custom solid timber handle Custom solid timber handle
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-165
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-04, D-05 N XC
SE8 3AU United Kingdom
100 mm
Frame:
Duco painted plywood
[JF-06]
Frame:
50 mm
Duco painted plywood
[JF-06]
Door leaf:
Duco painted plywood
[JF-03]
Door leaf: Door leaf:
Duco painted plywood Duco painted plywood
[JF-06] [JF-06]
2200 mm
2200 mm
2200 mm
2200 mm
2200 mm
2150 mm
Toilet Kitchen Storage Outside
D
06
FFL +0.00
50 mm 50 mm 750 mm 50 mm 40
50 750
850 mm
800 mm
D-06 Elevation From Kitchen D-06 Typical Detail D-07 Elevation From Outside D-07 Section
Scale 1:25 Scale 1:25 Scale 1:25 Scale 1:25
850 mm
50 750 mm 50
Toilet
200 mm
Storage
50 mm
Kitchen
D-06 Outside D-07
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-170
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-06, D-07 N XC
SE8 3AU United Kingdom
90 mm
Frame: Frame:
Solid wood natural finish Solid wood duco finish match to [JF-06]
40 mm
50 mm
50 mm
50 mm
50
Door leaf:
Duco painted
plywood [JF-06]
Door leaf:
Solid wood
natural finish (outside)
Veneer plywood [JF-01]
(inside)
2200 mm
2200 mm
2200 mm
2160 mm
2150 mm
2150 mm
2150 mm
2200
2150
Maid Maid Bathroom
Garden Maid's Quarters
Bedroom
FFL +0.00
50 mm 800 mm 50 mm 40 50 mm 700 mm 50 mm
40 mm
900 mm 200 mm 800 mm
D-09 D-10
40 mm
90 mm
150 mm
Veneer plywood [JF-01] (inside) Butt hinge
Hardware
Mortice lock, thumb turn from
Butt hinge
50 mm 700 mm 50 mm inside
Hardware
Door leaf: Mortice Lock, key from outside
Solid wood natural finish thumb turn from inside 800 mm Lever Handle
50 800 mm 50
Lever Handle
900 mm
Maid Bedroom
D-09 Plan D-10 Plan
Scale 1:25 Garden Scale 1:25
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-180
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-09, D-10 N XC
SE8 3AU United Kingdom
Fix panel:
Mirror [JF-15]
300
Solid wood [JF-05]
50 mm
40
50
Door leaf:
Duco painted plywood
[JF-04]
Door leaf:
2500 mm
2500 mm
Mirror [JF-15]
2200 mm
2200 mm
2160 mm
2150 mm
2150 mm
2200
Stairs Master Master Master
Landing Bedroom Bedroom Ensuite
40
50 700 mm 50 160 50 700 mm 50 40
800 mm 200 mm 800 mm 110 mm
D-11 Elevation from Stairs Landing D-11 Section D-12 Elevation from Master Bedroom D-12 Section
Scale 1:25 Scale 1:25 Scale 1:25
Scale 1:25
Door leaf:
D-11 Duco painted plywood [JF-05] D-12
40 720 40 Frame Solid wood [JF-04] Frame Solid wood [JF-04]
310
Door Leaf Duco painted plywood [JF-04] Door Leaf Mirror [JF-15] (outside)
200 mm
16040
40
110
(inside)
Hardware Door leaf:
Mortice lock, key from outside
thumb turn from inside Mirror [JF-15] Butt hinge
50 mm 700 mm 50 mm Hardware
50 mm 700 mm 50 mm Mortice lock, thumb turn from
Lever handle
inside
160 mm 800 mm 800 mm
Lever handle
Stairs Landing
Master
D-11 Plan D-12 Plan Bedroom
Scale 1:25 Scale 1:25
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-185
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-11, D-12 N XC
SE8 3AU United Kingdom
Frame: Frame:
Solid wood finish Solid wood finish
match to [JF-02] match to [JF-05]
40 mm
40 mm
50 mm
50 mm
50 mm
50 mm
Door leaf:
Duco painted plywood
[JF-02] Door leaf:
Duco painted plywood
[JF-05]
2200 mm
2200 mm
2200 mm
2160 mm
2160 mm
2150 mm
2150 mm
2150 mm
2150 mm
Inside Outside
Stairs
Studio
Landing
1000 mm
1000 mm
16040
200 mm
D-13 Elevation From Stairs Landing D-13 Section D-14, D-15 Elevation from outside D-14 Section
Scale 1:25 Scale 1:25 Scale 1:25 Scale 1:25
Stairs Landing
Guest Bedroom
40 mm
D
720 mm
800 mm
14 Guest Ensuite
D
90 800 mm
15
200 mm
40
40 720 mm 40
160
40 mm
40 mm
200 mm
D-13 D-14, D-15
Solid wood finish match to Solid wood finish match to
50 700 mm 50 Frame Frame
[JF-02] [JF-05]
800 mm Door Leaf Duco painted plywood [JF-02] Door Leaf Duco painted plywood [JF-05]
50 mm 700 mm 50 mm
Acoustic treatment Butt hinge
800 mm 90 150
Hardware
Studio Mortice Lock, key from outside
D-13 Plan Butt hinge
D-14,D-15 Plan thumb turn from inside
Scale 1:25 Hardware
Mortice Lock, key from outside Scale 1:25 Stairs Landing
thumb turn from inside
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-185
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-13, D-14, D-15 N XC
SE8 3AU United Kingdom
Fix Panel: Solid wood natural finish
370 mm
370 mm
Door leaf:
Solid wood natural finish
2100 mm
Sauna Garden
2100 mm
750 170
D-16 Gate Plan D-16 Gate Plan
Scale 1:25 880 mm Scale 1:25
D-16
inside Frame -
Pivot system
50 mm
Hardware
Mortice lock
outside
ZXC Studio
other statutory requirements, codes of practice and landlord requirements are implemented with design development & construction.
2. Do not scale from this drawing. All dimensions to be checked on site. ZXCS to be notified of any discrepancies between the drawing and site conditions.
3. Contractor to supply control samples of all finishes prior to procurement/construction for ZXCS approval. CLIENT SCALE STATUS A-195
4. The Contractor is to ensure all materials are fit for purpose and comply to regulations. Tatjana Saphira 1:25 @ A3 CD
5. Refer to Mechanical & Electrical (M&E) consultant’s info for fire safety and M&E layouts & specifications.
REVISION
6. The executive architect/contractor is to satisfy themselves with regards to the structural stability of all design intent information.
DRAWING TITLE DRAWN CHECKED
7. The executive Contractor is to agree any variations with ZXCS/client prior to construction or procurement/manufacture of any materials. ZXC STUDIO LTD. R1
8. To be read in conjunction with all relevant specifications, schedules and drawings. 8 the Terrace, Longshore, London D-16 N XC
SE8 3AU United Kingdom