Data Sheet PIM 2022

NEW: 2022 Series


Filter Assembly

Features
• 316 Stainless Steel construction
• Accepts Pall 21⁄2 ˝ diameter elements with M3 seals
• Optional bypass valve
• Flows to 110 Lpm (30 gpm)
• Pressures to: 17.9 bar (260 psi)
• Port size: 3⁄4 ˝ and 1˝

Notes and Specifications


Maximum Working Pressure: 17.9 bar (260 psi)
40° C (104° F)
Design Pressure: 13.8 bar (200 psi)
150° C (302° F)
2022 series filter housing
Materials of Construction: 316 stainless steel
Element Construction:
Element Pressure Drop.
Poly-Fine® XLD cartridges All polypropylene construction
For liquids other than water, multiply pressure drop x new
Dynalloy® cartridges Sintered 316 stainless steel
viscosity in cSt x new S.G.
fibers
Dynamesh™ cartridges Woven 316 stainless steel Dynalloy/Dynamesh Series Filter Cartridges
wire cloth 1
.7
Pressure Drop Information .5
Figure 1. .4
Housing pressure drop. .3
03

.2
Housing pressure drop is directly proportional to specific
04

06
gravity. D E
05

.1 RA
Differential Pressure (psid)

G
IA
Flow Rate (Lpm) .07 ED
09

M
0 25 50 75 100
12

.05
8 0.5 .04
.03
0.4 .02
6
40
Differential Pressure (psid)

Differential Pressure (bar)

0.3 .01
1 2 3 4 7 10 20 30 4050 70 100
4
Flow Rate (gpm)
0.2
Poly-Fine® XLD Series Filter Cartridges
2
0.1 0.3
4.5 µm
3.0 µm
0 0 0.25
0 10 20 30
Flow Rate (gpm)
0.3 10 µm
Note: For liquid other than water, multiply the pressure drop
Differential Pressure (psid)

by the specific gravity of the fluid. 0.15

0.1 20 µm

0.05

0
1 2 3 4 5 6
Flow Rate (gpm)
Dimensional Drawings Table 1: Seal Options Table 2: Port Options
Housing Cartridge Seals Code Port
Code Code*
4 3/16 ˝ A12 3/4 ˝ SAE J514 straight thread
1 1/2 ˝ H N Nitrile

B12 3/4 ˝ NPT
Z V Fluoro-
carbon A16 1˝ SAE J514 straight thread
2 5/8 ˝
* Poly-Fine XLD cartridges only B16 NPT
B B

OUTLET

INLET
1 5/16 ˝ Table 3: Filter Cartridge Options
TYP
Cartridge Series Code Rating Rating Method
3 3 µm

PALL
K=13 3/4 ˝ LG Ø3 9/16 ˝ (4) 1/4-20x1/2 ˝
L=23 3/4 ˝ LG
4.5 4.5 µm
1 3/16 ˝ Poly-Fine XLD
TYP
99.9% efficiency
10 10 µm
20 20 µm
03 3 µm
04 4 µm
Dynalloy 05 5 µm Absolute
06 6 µm

REQUIRED SPACE 09 9 µm
NEEDED FOR SHELL
REMOVAL 10 12 µm
K=12-5/8 ˝
L=22-1/2 ˝
40 40 µm
Dynamesh Nominal
Ordering Information 70 70 µm

Assembly P/N: 100 100 µm


H 2022 ++ T
Table 1 Table 2 Table 4 Table 5 Table 6 Table 7
Table 4: Length Options Table 5: Bypass Valve Options
Poly-Fine XLD Cartridge P/N: Housing Element Length Code Valve
Code Code (in)*
XLD - U M3 A 1.7 bar (25 psid)
K 10 10
Table 3 Table 4 Table 1 B 3.4 bar (50 psid)
L 20 20
Dynalloy Cartridge P/N: N Non- bypass
* Nominal length in inches
PSP - S M3*
Table 3 Table 4

*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540- Table 6: Differential Pressure Table 7: Mounting Bracket
456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon
Indicator Options* Options
Code Indicator Code Option
Dynamesh Cartridge P/N: E SST visual with glass 0 none
PWC - S M3* cover
1 Mounting bracket kit
Table 3 Table 4 B SST port plug
*Note: O-ring seals must be ordered separately. Order 2 pieces p/n D10540-
456 for nitrile, 2 pieces p/n D10540-457 for fluorocarbon * Note: Other indicator options
available — contact factory

Industrial Manufacturing Visit us on the Web at www.pall.com/m&e


25 Harbor Park Drive
Port Washington, NY 11050 Pall Corporation has offices and plants throughout the world in locations including: Argentina,
Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland,
Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand, Norway, Poland, Puerto
888.333.7255 toll free Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, United
516.484.3600 phone Kingdom, United States, and Venezuela. Distributors are located in all major industrial areas
516.484.6247 fax of the world.

© Copyright 2006, Pall Corporation. Pall, , are trademarks of Pall Corporation. ® Indicates a Pall
trademark registered in the USA. is a service mark of Pall Corporation.
7500/02 Series Spin-On Filter Assemblies

Description

Flows to 90 gpm (325 L/min) (7500); 150gpm (565 L/min) (7502)


Pressures to 200 psi (14 bar)
Port sizes:
1", 1-1/4" and 1-1/2" (7500)
1-1/2" and 2" (7502)

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Gasket Seal
Spin-On Canister
Mounting Surface
Gray Cast Iron Head
O-Ring Seals
Ultipor® III Element
Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level

Maximum Acceptable Working Pressure:


200 psi (14 bar)

Fatigue Pressure Rating:


200 psi (14 bar)
(100,000 cycles 0-200 psi)

Typical Burst Pressure:


290 psi (20 bar) (Gasket extrusion)

Temperature Range:
Nitrile seals -20°F to 225°F (-29°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
7500:
R length–8 lbs. (3.6 kg)
S length–9 lbs. (4.1 kg)

7502:
R length–20 lbs. (9.1 kg)
S length–22 lbs. (10 kg)

Filter Element Collapse Pressure:


7500–100 psid (7 bar)
7502–100 psid (7 bar)

Caution:
100 psi (7 bar) maximum for 7500/7502 Series non-bypass valve options (prevents possible filter element
collapse)

Dimensional Drawings
Performance
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

7500 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" N/A 0.21 0.18 0.14 0.10

8" 0.23 0.11 0.10 0.07 0.05

7502 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" N/A 0.10 0.09 0.07 0.05

8" 0.12 0.05 0.05 0.04 0.03

7502 series uses two 7500 series elements. Factors above are for flow through both elements in a 7502.

Ordering Information

Assembly P/N: H 750


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 7500 S


Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z* Fluorocarbon

*Non-standard: available for KP media only.

TABLE 2: HOUSING OPTIONS

Code Description

0 Single element

2 Double element

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D* Flange SAE J518c-Code 61

*7502 series only.

TABLE 4: PORT SIZE OPTIONS

Code Size Availability

16 1" 7500

20 1-1/4" 7500

24 1-1/2" 7500/7502

32 2" 7502*

*A & B port styles only.

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ* <1 2.5


KP 3 5

KN 6 7

KS 12 12

KT 25 22

*8" length only

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R 4

S 8

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV - Anti-backflow valve.

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

PL Same as PM but with plastic body

DL Same as DM but with plastic body


© Copyright Pall Corporation

Visit us on the Web at www.pall.com


7400 Series Spin-On Filter Assemblies

Description

Flows to 35 gpm (125 L/min)


Pressures to 250 psi (17 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Gasket Seal
Spin-On Canister
Optional Anti-Back Flow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
Mounting Surface
Gray Cast Iron Head
O-Ring Seal
Ultipor® III Element

Maximum Acceptable Working Pressure:


250 psi (17 bar)

Fatigue Pressure Rating:


250 psi (17 bar)
(60,000 cycles 0-250 psi)

Typical Burst Pressure:


400 psi (28 bar)

Temperature Range:
Nitrile seals -20°F to 225°F (-29°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 4 lbs. (1.8 kg)
S length– 4.6 lbs. (2.1 kg)

Filter Element Collapse Pressure:


7400 series–100 psid (7 bar)

Caution:
100 psi (7 bar) maximum for 7400 Series non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

7400 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 0.82 0.36 0.30 0.22 0.15


8" 0.43 0.19 0.15 0.12

Ordering Information

Assembly P/N: H 7400


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 7400 S


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z* Fluorocarbon

*Non-standard: available for KP media grade in 4" length only.

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

TABLE 3: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12
KT* 25 22

* 4" length only.

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

R 4

S 8

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

PL Same as PM but with plastic body

DL Same as DM but with plastic body


© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8924 Series Filter Assemblies

Description

Featuring Coreless Element Technology

Flows to 75 gpm (284 L/min)


Pressures to 400 psi (27.5 bar)
Port sizes: 1" and 1¼"

Specifications

Maximum Acceptable Working Pressure:


400 psi (27.5 bar)

Fatigue Pressure Rating:


400 psi (27.5 bar)
0-2,000,000 cycles

Typical Burst Pressure:


1500 psi (103.4 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


150 psid (10 bar)

Materials of Construction:
Ductile iron head/cover
Steel tube
Powder coat finish

Dimensional Drawings
Performance

Pressure Drop Information


Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9404 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.29 0.15 0.11 0.08 0.06

13" 0.19 0.09 0.07 0.05 0.04

16" 0.09 0.05 0.04 0.03 0.02

Ordering Information

Assembly P/N: H 8924


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9404 F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread


Table 3: Port Size Options

Code Size

16 1"

20 1 1/4"

Table 4: Filter Element Options

Code x 200 x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 5: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

*Use code in second column for element part no.


**Nominal length in inches

Table 6: Bypass Valve Options

Code Description

A 25 psid

B 50 psid

W Non bypass
Table 7: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

S Electrical switch with MS receptacle

B Bleed plug and seal in place of indicator

3 "P" in cover, "S" in head

2 "P" in cover, "L" in head

1 Plastic plug

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8300/04/10/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 300 gpm (1135 L/min)
Pressures to 400 psi (28 bar)
Port sizes: 1-1/2", 2 and 2-1/2"

With Dual Manifold:


Flows to 600 gpm (2270 L/min)
Port Size: 3"

Specifications

Features

T-Handle Easy Service Cover


Bleed Port Plug
O-Ring Seals
Optional Differential Pressure Devices
Anodized Aluminum Alloy-Head, Tube and Cover
Fill Port
Full Flow Fast Response Bypass Valves
Ultipor® III Element
Drain Port and Plug

Maximum Acceptable Working Pressure:


400 psi (28 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
330 psi (23 bar)

Typical Burst Pressure:


2100 psi (145 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
U length– 45 lbs. (20.5 kg)
X length– 92 lbs. (42 kg)

Filter Element Collapse Pressure:


8300/04/14–150 psid (10 bar)
8310–100 psid (7 bar)

Caution:
120 psi (8 bar) maximum for 8300/04/14 Series
80 psi (5.5 bar) maximum for 8310
Series non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8300 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.078 0.034 0.028 0.021 0.014

39" 0.039 0.015 0.012 0.009 0.006

8304 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.101 0.049 0.041 0.031 0.022

39" 0.038 0.018 0.015 0.012 0.008

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT
16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

Ordering Information

Assembly P/N: H 83
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 83 F
Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Option

00 Standard capacity

04 Coreless, standard capacity

10 High capacity

14 Coreless, high capacity

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

24 1-1/2" A, D

32 2" A, D
40 2-1/2" D

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

U 16

X 39

* Use Code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

Y Non-bypass with 16 psid indicator

N Non-bypass with 35 psid indicator

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout


L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Electrical indicators in base only.

Dual Manifold P/N: H 8300-SP2A3


Table1

Mounting Bracket P/N: 1129210

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8110 Series Filter Assemblies

Description

Flows to 40 gpm (145 L/min)


Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Optional Differential Pressure Devices


Gray Cast Iron Head
Painted External Finish
Drawn Steel Bowl
High Strength Fatigue Rated Housing
Full Flow Fast Response Bypass Valve
O-Ring Seals
Ultipor® III Element
Optional Drain Port (Not Shown)

Maximum Acceptable Working Pressure:


600 psi (41 bar)

Fatigue Pressure Rating:


600 psi (41 bar)
(2,000,000 cycles to 600 psi)

Typical Burst Pressure:


2400 psi (165 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 9 lbs. (4.1 kg)
S length– 10 lbs. (4.6 kg)
T length– 11 lbs. (5 kg)

Filter Element Collapse Pressure:


9100–290 psid (20 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9100 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 1.01 0.44 0.36 0.27 0.19

8" 0.53 0.25 0.21 0.16 0.11

13" 0.32 0.14 0.11 0.09 0.06


Ordering Information

Assembly P/N: H 8110


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 9100 F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

TABLE 3: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 5: LENGTH OPTIONS*


Assembly Code Element Code**

R 4

S 8

T 13

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid ± 5

B 50 psid ± 5

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

TABLE 8: OPTIONAL DRAIN PORTS

Code Description

Omit No drain

6 1/4" SAE drain port and plug

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8600/04/06 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 40 gpm (145 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Easy Service Rotolok Ring
Drawn Steel Bowl
Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
High Strength Fatigue Rated Housing
Gray Cast Iron Head
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


600 psi (41 bar)

Fatigue Pressure Rating:


600 psi (41 bar)
(2,000,000 cycles to 600 psi)

Typical Burst Pressure:


2800 psi (193 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 8 lbs. (3.6 kg)
S length– 9 lbs. (4.1 kg)
T length- 11 lbs. (5 kg)

Filter Element Collapse Pressure:


9600–290 psid (20 bar)
9604–150 psid (10 bar)
9606–600 psid (207 bar)

Caution:
120 psi (8 bar) maximum for 8600 Series non-bypass valve options (prevents possible filter element collapse).

Dimensional Drawings
Performance
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600/9604* Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 0.81 0.36 0.29 0.22 0.15

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.07 0.07 0.05

*9604 not available in 4" length.

9606 Series Element P factor (psid/gpm)

Length DS

4" 0.17

8" 0.09

13" 0.05

Ordering Information

Assembly P/N: H 860


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 960 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile
Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

CODE OPTION

0 Standard

4 Coreless

6* High collapse

* 8606 is available with non-bypass valve options and ‘DS’ filter media
only.

TABLE 3: PORT STYLE OPTIONS

CODE PORT STYLE

A SAE J514 straight thread

B NPT tapered pipe thread

TABLE 4: PORT SIZE OPTIONS

CODE SIZE

12 3/4"

16 1"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßX 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DS* 12 10

* 8606 only.
TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use code in second column for element part no.


** Nominal length in inches.
***Not available for 8604 series/9604 element.

TABLE 7: BYPASS VALVE OPTIONS

CODE DESCRIPTION

A 25 psid

B 50 psid

W* Non-bypass

8 25 psid with ABFV**

9 50 psid with ABFV**

V* Non-bypass with ABFV**

* Not available for 8604.


** ABFV– Anti-backflow valve.

TABLE 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual /electrical with DIN connector

B Plug in place of indicator

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


2804 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 45 gpm (170 L/min)
Pressures to 600 psi (41.4 bar)
Port size 1"

Specifications

Maximum Acceptable Working Pressure:


600 psi (41.4 bar)

Fatigue Pressure Rating:


400 psi (27.5 bar)
(106 cycles per NFPA T2.6.1-1991)

Typical Burst Pressure:


2000 psi (140 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)

Filter Element Collapse Pressure:


150 psid (10 bar)

Materials of Construction:
Cast Aluminum Head/Bowl

Fluid Compatibility:
Compatible with petroleum oils.
Not recommended for use with water based fluids.
Fluorocarbon seals are required for industrial phosphate esters, diesters and specified synthetics.

Dimensional Drawings
Performance

Pressure Drop Information


Element Pressure Drop Factor.
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9104 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.53 0.25 0.21 0.16 0.11

Ordering Information

Assembly P/N: H 2804 A 16 S


Table1 Table2 Table3 Table4

Element P/N: HC 9104 F 8


Table2 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: FILTER ELEMENT OPTIONS

Code x 200 x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non bypass

TABLE 4: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

Contact Information
FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8200/04/10/14 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 110 gpm (400 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 1", 1-1/4" and 1-1/2"

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Easy Service Rotolok Ring
Drawn Steel Bowl
Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
High Strength Fatigue Rated Housing
Gray Cast Iron Head
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


600 psi (41 bar)

Fatigue Pressure Rating:


600 psi (41 bar)
2,000,000 cycles

Typical Burst Pressure:


2800 psi (193 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 17 lbs. (7.75 kg)
T length– 20 lbs. (9.1 kg)
U length– 23 lbs. (10.5 kg)

Filter Element Collapse Pressure:


8200–150 psid (10 bar)
9604–150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8200/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" O.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

Ordering Information

Assembly P/N: H 82
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 8200 (8200/10 Housing) F


Table5 Table6 Table1

HC 9604 (8204/14 Housing) F


Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon
TABLE 2: ELEMENT OPTIONS

Code Option*

00 ‘L’ (standard element)

04 ‘L’ (coreless element)

10 ‘T’ (standard element)

14 ‘T’ (coreless element)

* 'L' = L head
'T' = T head

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c–Code 61

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

16 1" A, B

20 1-1/4" A,B,D

24 1-1/2" A,B,D

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*


Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

8 25 psid with ABFV*

9 50 psid with ABFV*

* ABVF-anti-backflow valve available with 8214 model only.

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

1 Machined part with plastic shipping plug

TABLE 9: EJECTOR SPRING OPTIONS

Code Description

N No ejector spring

S Ejector spring
© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8800/10 Series Rotolok Filter Assemblies

Description

Flows to 120 gpm, 454 L/min


Pressures to 600 psi (41 bar)
Port sizes: 1-1/2" and 2"

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Easy Service Rotolok Ring
Drawn Steel Bowl
Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
High Strength Fatigue Rated Housing
Gray Cast Iron Head
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


600 psi (41 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
600 psi (41 bar)

Typical Burst Pressure:


2800 psi (193 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 23 lbs. (10.5 kg)
T length– 25 lbs. (11.4 kg)
U length– 27 lbs. (12.3 kg)

Filter Element Collapse Pressure:


150 psid (10 bar)

Caution:
120 psid (8 bar) maximum for non-bypass valve options
(prevents possible filter element collapse).

Dimensional Drawings
Performance
Element Pressure Drop Factor.
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8800 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.37 0.17 0.14 0.10 0.07

13" 0.23 0.10 0.08 0.06 0.04

16" 0.17 0.08 0.06 0.05 0.03

Ordering Information

Assembly P/N: H 88
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 8800 F


Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals
H Nitrile

Z Fluorocarbon

Table 2: Head Options

Code Head Option

00 'L' Head

10 'T' Head

Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-code 61

Table 4: Port Size Options

Code Size

24 1-1/2"

32 2"

Table 5: Filter Element Options

Code ßx 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code**

S 8

T 13
U 16

* Use code in second column for element part no.


** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid

B 50 psid

W* Non-bypass

8* 25 psid with ABFV

9* 50 psid with ABFV

V* Non-bypass with ABFV

* ABFV- Anti-backflow valve, available for 'T' head units only: 8810.

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Table 9: Auxiliary Ports

Code Auxiliary Port

N Unmachined

B Both† sides

R* Right only†

L* Left only†
* Special order-contact factory.
† Shipping plugs provided only.

Table 10: Ejector Spring Options

Code Description

N No ejector spring

S Ejector spring

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8900/04/10/14 Series Rotolok Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 200 gpm (755 L/min)
Pressures to 600 psi (41 bar)
Port sizes: 2" and 2-1/2"

Specifications

Features

Optional Differential Pressure Devices


Full Flow Fast Response Bypass Valve
Easy Service Rotolok Ring
Drawn Steel Bowl
Optional Anti-Backflow Valve (not shown). Prevents drainage of reservoir or lines where filter is
mounted below fluid level
High Strength Fatigue Rated Housing
Gray Cast Iron Head
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


600 psi (41 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
600 psi (41 bar)

Typical Burst Pressure:


2800 psi (193 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 26 lbs. (12 kg)
T length– 28 lbs. (13 kg)
U length– 30 lbs. (14 kg)

Filter Element Collapse Pressure:


150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor.


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8900 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.30 0.14 0.12 0.09 0.06

13" 0.19 0.09 0.07 0.05 0.04

16" 0.14 0.07 0.05 0.04 0.03

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.36 0.17 0.14 0.10 0.07

13" 0.21 0.10 0.08 0.06 0.04

16" 0.15 0.07 0.06 0.04 0.03

Ordering Information

Assembly P/N: H 89
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 8900 (8900/10 Housing) F


HC 8904 (8904/14 Housing) Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element/Head Options

Code Option*

00 'L' (standard element)

04 'L' (coreless element)

10 'T' (standard element)

14 'T' (coreless element)

"L" = L Head. "T" = T Head.


Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-code 61

Table 4: Port Size Options

Code Size

32 2"

40* 2-1/2"

* D ports only.

Table 5: Filter Element Options

Code ßx 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid

B 50 psid
W* Non-bypass

8* 25 psid with ABFV

9* 50 psid with ABFV

V* Non-bypass with ABFV

* ABFV - Anti-backflow valve, available for 'T' head units only: 8910/14.

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Table 9: Auxiliary Ports

Code Auxiliary Ports

N Unmachined

B Both† sides

R* Right only†

L* Left only†

* Special order-contact factory.


† Shipping plugs provided only.

Table 10: Ejector Spring Options

Code Description

N No ejector spring

S Ejector spring

© Copyright Pall Corporation


Visit us on the Web at www.pall.com
9650/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 85 gpm (309 L/min)
Pressures to 2000 psi (140 bar)
Port sizes: 1" and 1-1/4"

Specifications

Features

Optional Differential Pressure Devices


Ductile Iron Head
Ductile Iron Cover
Steel Tube
Ultipor® III Element
Full Flow Fast Response Bypass Valve

Maximum Acceptable Working Pressure:


2000 psi (140 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
2000 psi (140 bar)
1500 psi (103 bar) with K ports

Typical Burst Pressure:


10,000 psi (690 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 24 lbs. (11 kg)
U length– 35 lbs. (16 kg)

Filter Element Collapse Pressure:


9604–150 psid (10 bar)
9650–290 psid (20 bar)
9651– 3000 psid (207 bar)

Materials of Construction:
Ductile iron head and cover steel tube

DImensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9650/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

16" 0.20 0.09 0.07 0.05 0.04

9651 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

16" 0.25 0.07

Ordering Information

Assembly P/N: H 965


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 96 F
Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon
TABLE 2: ASSEMBLY OPTIONS

Housing Code Element Code Option

0 50 Standard element

1 51 High collapse element

4 04 Coreless element

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

K Manifold mount

TABLE 4: PORT SIZE OPTIONS

Code Size Style Availability

16 1" A, B

20 1-1/4" A,B,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP 3 5

DT 17 15

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

U 16

*Use code in second column for element part no.


**Nominal length in inches.
TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid (9650, 9654)

W Non-bypass (9651 only)

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9020/21/24 Series Filter Assemblies

Description

Featuring Coreless Element Technology

Flows to 20 gpm (75 L/min)


Pressures to 3000 psi (207 bar)
Port size: 3/4"

Specifications

Features

Full Flow Fast Response Bypass Valve


Forged Aluminum Alloy Bowl (Anodized)
Optional Differential Pressure Devices
Extruded Aluminum Alloy Head (Anodized)
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure: 3000 psi (207 bar)

Fatigue Pressure Rating:


(NFPA/T2.6 1 -1974 category 2/90)
R length-1800 psi (124 bar)
S length-1500 psi (103 bar)

Typical Burst Pressure:


15,000 psi (1035 bar)

Temperature Range:
Nitrile seals-45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals-20°F to 250°F (-27°C to 121°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length-3.7 lbs. (1.7 kg)
S length-5 lbs. (2.3 kg)

Filter Element Collapse Pressure:


9020-290 psid (20 bar)
9021-3000 psid (207 bar)
9024-150 psid (10 bar)

Dimensional Drawings
Performance

Pressure Drop Information

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9020 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4" 1.90 0.82 0.54 0.35 0.21

8" 0.96 0.41 0.27 0.18 0.11

9021 Series Element P factor (psid/gpm)

Length DP DT

4" 2.71 0.68

8" 1.35 0.34

9024 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 1.12 0.48 0.31 0.21 0.13

Ordering Information

Assembly P/N: H 902


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 902 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element Options

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)


Table 3: Port Style Options

Code Port Style

A SAE J514 straight thread

L Manifold side mount*

K Manifold mount

*Contact factory for drawings.

Table 4: Port Size Options

Code Size

12 3/4"

TABLE 5: FILTER ELEMENT OPTIONS

CODE ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9021 series only.

Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

*Use code in second column for element part no.


**Nominal length in inches
***Not available for 9024 series

Table 7: Bypass Valve Options


Code Description

B 50 psid-9020/9024 only

W Non bypass 9021 only

Table 8: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9720/24 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 125 gpm (475 L/min)
Pressures to 4500 psi (310 bar)
Port size: 1-1/2"

Specifications

Features

Bleed Valve
Extra Long Threads
Full Flow Fast Response Bypass Valve
Ductile Head and Cap
O-Ring Seals
Heavy Wall Thickness Steel Tube
Ultipor® III Element
Optional Differential Pressure Devices
Drain Port and Plug
Flat Mounting Pad

Maximum Acceptable Working Pressure:


4500 psi (310 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
3000 psi (207 bar)

Typical Burst Pressure:


15,000 psi (1035 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
1-high 61 lbs. (27.8 kg)
2-high 81 lbs. (37 kg)
3-high 101 lbs. (46 kg)

Filter Element Collapse Pressure:


9700–290 psid (20 bar)
8904–150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9700 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT
9" 0.26 0.12 0.10 0.08 0.05

18" 0.12 0.06 0.05 0.04 0.03

27" 0.08 0.04 0.03 0.02 0.02

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.36 0.17 0.14 0.10 0.07

16" 0.15 0.07 0.06 0.04 0.03

26" 0.10 0.04 0.04 0.03 0.02

Ordering Information

Assembly P/N: H 972 24


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9720 (9720 Housing) F


8904 (9724 Housing) Table4 Table5 Table1

Add a "1" suffix to specify a single length element for housing length option "2" or "3". Omit to specify multiple,
single-length stacked elements. Note: Choose from the options in the following tables to compile the
specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

K Manifold mount
TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 5: Length Options*

Assembly Code Element Code**

1 9 (9720)

2 18 (9720)

3 27 (9720)

S 8 (9724)

U 16 (9724)

V 26 (9724)

* Use code in second column for element part no.


** Nominal length in inches.
To stack 9" elements use Pall P/N HBS630-ID5 (reusable).

Table 6: Bypass Valve Options

Code Description

B 50 psid

C 50 psid bypass with reverse flow

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle


V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9850/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 35 gpm (125 L/min)
Pressures to 4061 psi (280 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Optional Differential Pressure Devices


Ductile Iron Head
Forged Steel Bowl
Optional Drain Port and Plug
Full Flow Fast Response Bypass Valve
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


4061 psi (280 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
3500 psi (241 bar)

Typical Burst Pressure:


18,000 psi (1240 bar)

Temperature Range:
Nitrile seals -45°F to 225°F(-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 9.7 lbs. (4.4 kg)
S length– 12.1 lbs. (5.5 kg)
T length– 15.2 lbs. (6.9 kg)

Filter Element Collapse Pressure:


9800– 290 psid (20 bar)
9801– 3000 psid (207 bar)
9804-150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT
4" * 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13

13" 0.58 0.23 0.18 0.13 0.08

*9800 only

9801 Series Element P factor (psid/gpm)

Length DP DT

4" 1.82 0.84

8" 0.90 0.39

13" 0.56 0.17

Ordering Information

Assembly P/N: H 985


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 980 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread


TABLE 4: PORT SIZE OPTIONS

Code Size Port Style

12 3/4" A

16 1" A, B

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9851 only.

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use code in second column for element part no.


** Nominal length in inches.
*** 9850/51 only.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 9850/54 only

W Non-bypass- 9851 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE


OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

TABLE 9: SPECIAL OPTIONS

Code Description

L Indicator location
(left or right when facing inlet port)

R Left is standard

TABLE 10: DRAIN PORT OPTIONS

Code Description

Omit No drain port

P Drain port

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9800/01/04 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 55 gpm (200 L/min)
Pressures to 6000 psi (414 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Ductile Iron Head


O-Ring Seals
Forged Steel Bowl
Drain Port and Plug
Optional Differential Pressure Devices
Bleed Port and Plug
Full Flow Fast Response Bypass Valve
Ultipor® III Element

Maximum Acceptable Working Pressure:


6000 psi (414 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
3500 psi (241 bar)

Typical Burst Pressure:


20,000 psi (1380 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 9.7 lbs. (4.4 kg)
S length– 12.4 lbs. (5.65 kg)
T length– 15.7 lbs. (7.16 kg)

Filter Element Collapse Pressure:


9800– 290 psid (20 bar)
9801– 3000 psid (207 bar)
9804– 150 psid (10 bar)

Dimensional Drawings
Performance
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13

13" 0.58 0.23 0.18 0.13 0.08

*9800 only.

9801 Series Element P factor (psid/gpm)

Length DP DT

4" 1.82 0.84

8" 0.90 0.39

13" 0.56 0.17

Ordering Information

Assembly P/N: H 980


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 980 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals
H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT tapered pipe thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

K Manifold mount

Table 4: Port Size Options

Code Size Port Style

12 3/4" A

16 1" A,B,D,E,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9801 only.
Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

T 13

* Use Code in second column for element part no.


** Nominal length in inches.
***9800/01 series only.

Table 7: Bypass Valve Options

Code Description

B 50 psid-9800/04 only

W Non-bypass- 9801 only

C 50 psid bypass with reverse flow (9800 only)

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 '
P'and '
L'

3 '
P'and '
S'

TABLE 9: MOUNTING BRACKET OPTIONS

Code Description

1 1 mounting bracket

2 2 mounting brackets

- No mounting brackets
© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9660/61/64 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 150 gpm (565 L/min)
Pressures to 6000 psi (414 bar)
Port sizes: 1", 1-1/4" and 1-1/2"

Specifications

Features

Bleed Port and Plug


Multiple Port Options
Ductile Iron Head
Forged Steel Bowl
Optional Differential Pressure Devices
Full Flow Fast Response Bypass Valve
O-Ring Seals
Ultipor® III Element
Drain Port and Plug

Maximum Acceptable Working Pressure:


6000 psi (414 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
3000 psi (207 bar)

Typical Burst Pressure:


20,000 psi (1380 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length– 22 lbs. (10 kg)
S length– 27 lbs. (12.3 kg)
T length– 33 lbs. (15 kg)
U length– 44 lbs. (20 kg)

Filter Element Collapse Pressure:


9600– 290 psid (20 bar)
9601– 3000 psid (207 bar)
9604– 150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9600/9604 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 0.81 0.36 0.29 0.22 0.15

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

* 9600 only.

9601 Series Element P factor (psid/gpm)

Length DP DT

4" 1.04 0.25

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Ordering Information

Assembly P/N: H 966


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9 Table10

Element P/N: HC 960 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)


TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

K Manifold mount (9660/61 only)

Table 4: Port Size Options

Code Size Style Availability

16 1" A,D,E

20 1-1/4" A,D,E

24 1-1/2" A,B,D,K

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9661 only.

Table 6: Length Options*

Assembly Code Element Code**

R*** 4

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.
*** Not available for 9664.
Table 7: Bypass Valve Options

Code Description

B 50 psid-9660/64 only

C 50 psid bypass with reverse flow (9660/64 only)

W Non-bypass- 9661 only

K Non-bypass with reverse flow-9661 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 '
P'and '
L'

3 '
P'and '
S'

TABLE 9: MOUNTING BRACKET OPTIONS

Code Description

1 1 mounting bracket

2 2 mounting brackets

- No mounting brackets

TABLE 10: SPECIAL OPTIONS

Code Description

Y411* Heavy duty ‘B’,‘C’ or ‘K’ valve for highly cyclic applications

3/4" mounting bolt holes for ‘K’ head


Y151
(1/2" bolt holes standard)

* Not available for 9664


© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9900/01/04 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 250 gpm (910 L/min)
Pressures to 6000 psi (414 bar)
Port sizes: 1-1/2" and 2"

Specifications

Features

Bleed Port and Plug


Multiple Port Options
Steel Tube
Ductile Iron Head
Optional Differential Pressure Devices
Full Flow Fast Response Bypass Valve
O-Ring Seals
Ultipor® III Element

Maximum Acceptable Working Pressure:


6000 psi (414 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
3000 psi (207 bar)

Typical Burst Pressure:


15,000 psi (1035 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
T length– 80 lbs. (36.5 kg)
V length– 108 lbs. (49.2 kg)
X length– 134 lbs. (61.1 kg)

Filter Element Collapse Pressure:


9400– 290 psid (20 bar)
9901– 3000 psid (207 bar)
9404– 150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9400/9404 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

13" 0.19 0.09 0.07 0.05 0.04

26" 0.09 0.05 0.04 0.03 0.02

39" 0.06 0.03 0.02 0.02 0.01

9901 Series Element P factor (psid/gpm)

Length DP DT

13" 0.19 0.06

26" 0.10 0.03

39" 0.06 0.02

Ordering Information

Assembly P/N: H 990 Note: For heavy duty valve


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8
(B,C,or K option) add Y128 to
end of part number

Element P/N: HC F
Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Element Code Rating

0 9400 290 psid (standard)

1 9901 3000 psid (high collapse)

4 9404 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS


Code Port Style

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

24 1-1/2"

32 2"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*9901 only.

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

V 26

X 39

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 9900/04 only


C 50 psid bypass with Reverse Flow-9900/04 only

W Non-bypass-9901 only

K Non-bypass with reverse flow-9901 only

N No element no flow- valve 9901 only

Valve options W,K,N require use of 3000 psid collapse element (series
code ending in ‘l’).

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 'P' and 'L'

3 'P' and 'S'

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


4510/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 35 gpm (130L/min)
Pressures to 6500 psi (450 bar)
Port sizes: 3/4" and 1"

Specifications

Features

Optional Differential Pressure Devices


Patented Sealing Interface - Positive sealing with standard O-rings
Forged Steel Bowl
Ductile Iron Head
Full Flow Fast Response Bypass Valve
Sampling or Bleed Port
Ultipor® III Element
Optional ¼" Drain Port

Maximum Acceptable Working Pressure:


6500 psi (450 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1991 category B/90)
5800 psi (400 bar)-Stainless steel indicators required above 3000 psi (207 bar) RFP

Typical Burst Pressure:


23,000 psi (1600 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
R length - 15 lbs. (6.8 kg)
S length - 18 lbs. (8.2 kg)

Filter Element Collapse Pressure:


9800-290 psid (20 bar)
9801-3000 psid (207 bar)
9804-150 psid (10 bar)

Dimensional Drawings
Performance

Pressure Drop Information


Element Pressure Drop Factor.
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cST), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9800/9804 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

4"* 1.83 0.72 0.56 0.40 0.26

8" 0.95 0.37 0.29 0.21 0.13


*9800 series only.

9801 Series Element P factor (psid/gpm)

Length DP

4" 1.82

8" 0.90

Ordering Information

Assembly P/N: H 451 3


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 980 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating
0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

12 3/4"

16 1"

TABLE 5: FILTER ELEMENT OPTIONS

Code x 200 x(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4511 ONLY.
*Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000
psi, stainless steel indicators are necessary. Designate with an 'H' in
model Code (e.g., PH, LH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

R*** 4
S 8

*Use Code in second column for element part no.


**Nominal length in inches.
***Not available for 4514.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid - 4510/14 only

C 50 psid bypass with


reverse flow-4510 only

W Non-bypass - 4511 only

K Non-bypass with reverse


flow - 4511 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 'P' and 'L'

3 'P' and 'S'

Contact Information

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255)

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


4610/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 70 gpm (265 L/min)
Pressures to 6500 psi (450 bar)
Port sizes: 1" and 1-1/4"

Specifications

Features

Optional Differential Pressure Devices


Patented Sealing Interface - Positive sealing with standard O-rings
Forged Steel Bowl
Ductile Iron Head
Full Flow Fast Response Bypass Valve
Sampling or Bleed Port
Ultipor® III Element
Optional ¼" Drain Port

Maximum Acceptable Working Pressure:


6500 psi (450 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1991 category B/90)
5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP

Typical Burst Pressure:


23,000 psi (1600 bar)

Filter Element Collapse Pressure:


290 psid (20 bar) minimum per ISO 2941

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 33 lbs. (15 kg)
T length– 39 lbs. (17.7 kg)

Filter Element Collapse Pressure:


9100–290 psid (20 bar)
9101–3000 psid (207 bar)
9104–150 psid (10 bar)

Dimensional Drawings
Performance
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9100/9104 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.53 0.25 0.21 0.16 0.11

13" 0.32 0.14 0.11 0.09 0.06

9101 Series Element P factor (psid/gpm)

Length DP DT

8" 0.55 0.23

13" 0.34 0.16

Ordering Information

Assembly P/N: H 461 3


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 910 F


Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Code Rating

0 290 psid (standard)

1 3000 psid (high collapse)

4 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS


Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

16 1"

20 1-1/4"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4611 only
*Indicators fatigue rated at 3000 psi. For cyclic pressures above 3000
psi, stainless steel indicators are necessary. Designate with an ‘H’ in
model Code (e.g., PH, DH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

* Use Code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 4610/14 only


C 50 psid bypass with reverse flow-4610 only

W Non-bypass- 4611 only

K Non-bypass with reverse flow-4611 only

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


4710/11/14 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 130 gpm (490 L/min)
Pressures to 6500 psi (450 bar)
Port sizes: 1-1/4" and 1-1/2"

Specifications

Features

Optional Differential Pressure Devices


Patented Sealing Interface - Positive sealing with standard O-rings
Forged Steel Bowl
Ductile Iron Head
Full Flow Fast Response Bypass Valve
Sampling or Bleed Port
Ultipor® III Element
Optional ¼" Drain Port

Maximum Acceptable Working Pressure:


6500 psi (450 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1991 category B/90)
5800 psi (400 bar) Stainless steel indicators required above 3000 psi (207 bar) RFP

Typical Burst Pressure:


23,000 psi (1600 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
T length- 54 lbs. (24.5 kg)
U length- 60 lbs. (27 kg)

Filter Element Collapse Pressure:


9600– 290 psid (20 bar)
9601– 3000 psid (207 bar)
4704– 150 psid (10 bar)

Dimensional Drawings
Performance

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

13" 0.32 0.08

16" 0.25 0.07

Ordering Information

Assembly P/N: H 471 3


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC F
Table2 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61


E Flange SAE J518c-Code 62

TABLE 4: PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

*4711 only.
*Indicators fatigue rated at 3000 psi. For cyclic
pressures above 3000 psi, stainless steel indicators
are necessary. Designate with an ‘H’ in model code
(e.g., PH, DH, etc.).

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

B 50 psid- 4710/14 only

C 50 psid bypass with reverse flow-4710 only

W Non-bypass- 4711 only

K Non-bypass with reverse flow-4711 only


TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8340/70 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 400 gpm (1500 L/min)
Pressures to 400 psi (28 bar)
Port sizes: 3" and 4"

Specifications

Features

8310 or 8314 Assembly (Ultipor® III Element)


Commuter Valve - Built in Design Requires No External Lines. Use to Equalize Pressure During
Element Change
Duplex Check Valve at Outlet - Seals Off-Line Filter to Prevent Backflow; Simplifies Element Change
Ball Type Open Center Transfer Valve - Ensures Continuous Filtration While Changing Elements
Without Shutting Down the Machine

Maximum Acceptable Working Pressure:


400 psi (28 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
330 psi (23 bar)

Typical Burst Pressure:


2100 psi (145 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

8340/8370: U length–165 lbs. (75 kg)


X length– 260 lbs. (118 kg)
8342/8372: X length– 475 lbs. (215 kg)
8343/8373: X length– 680 lbs. (310 kg)
8344/8374: X length– 890 lbs. (405 kg)

Filter Element Collapse Pressure:


8310–100 psid (7 bar)
8314–150 psid (10 bar)

Materials of Construction:
Head, cover, handle, tube, manifold and valve bodies – aluminum alloy.
Center post, core, and internal valve parts – coated carbon steel.

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor*


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

* Based on flow through each housing/element. Divide total flow by


number of housings per side to determine flow per each
housing/element.

Ordering Information

Assembly P/N: H 83
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8

Element P/N: HC 83 F
Table2 Table5 Table6 Table1
Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code* Description

4 10 Conventional

7 14 Coreless

*Nominal length in inches.


Use code in second column for element part no.

TABLE 3: QUANTITY OF HOUSINGS

Code Description

0 2 Housings (1/side)

2 4 Housings (2/side)

3 6 Housings (3/side)

4 8 Housings (4/side)

TABLE 4: PORT SIZE OPTIONS

Code Size

D48 3" flange SAE J518c-Code 61

D64 4" flange SAE J518c-Code 61

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22
TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code**

U 16

X 39

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

Y Non-bypass with 16 psid indicator

N Non-bypass with 35 psid indicator

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 '
P'and '
L'

3 '
P'and '
S'

Electrical indicators in base only.


© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8384/85 Series Service Bypass Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 200 gpm (760 L/min)
Pressures to 400 psi (28 bar)
Port sizes: 2" and 2-1/2" SAE split flange

Specifications

Features

Optional Differential Pressure Device


Changeover Handle with Latching Pin Mechanism
8310 or 8314 Series (Ultipor® III Element)

Maximum Acceptable Working Pressure:


400 psig (28 bar)

Fatigue Pressure Rating:


330 psig (23 bar)
(107 cycles per NFPA T2.6.1-1974)

Typical Burst Pressure:


2100 psig (145 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C) 140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


8314–150 psid (10 bar)
8310–100 psid (7 bar)

Materials of Construction:
Head, cover, handle, tube, manifold and valve bodies – aluminum alloy. Center post, core, and internal valve
parts – coated carbon steel.

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8310/14 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

16" 0.089 0.047 0.040 0.031 0.022

39" 0.034 0.018 0.015 0.012 0.008

Ordering Information

Assembly P/N: H 838 D


Table1 Table2 Table3 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 831 F


Table4 Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.
Table 1: Seal Options

Code Seals

H Buna N

Z Fluorocarbon

Table 2: Housing Series Options

Code Element

4 Coreless (use Code '4' in table 4)

5 Standard (use Code '0' in table 4)

Table 3: Port Size Options

Code Size

32 2" SAE flange

40 2-1/2" SAE flange


Table 4: Element Series Options

Code Options

4 8314 series coreless filter elements

0 8310 series filter elements (with core)

Table 5: Filter Element Options

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

Table 6: Length Options*

Assembly Code Element Code** Dry Weight Maximum

U 16 61 lb.

X 39 82 lb.

* Use code in second column for element part no.


** Nominal length in inches.

Table 7: Bypass Valve Options

Code Description

A 25 psid ± 3 psid bypass

B 50 ± 5 psid bypass

Y Without bypass* 16 psid P indicator

N Without bypass* 35 psid P indicator

1 Without bypass* with P device F or B

*Caution: If non-bypass configuration is selected, do not use in systems with surge pressures over 90 psig
(8385) or 120 psig (8384), in order to avoid possible filter element collapse and containment passing
downstream.

Table 8: Differential Pressure Device Options


Code Description Location

B Plug in place of P device Both

P Visual indicator with thermal lockout Cover

D 'P' type with no thermal lockout Cover

L Electrical switch (SPDT) with 6" leads Base

S Electrical switch with MS receptacle Base

T 'L' type with DIN connector Base

M 'T' type with wiring cap Base

2 'P' and 'L' As above

3 'P' and 'S' As above

Table 9: Handle Orientation Options

Code Handle Orientation

L Handle on left side when facing inlet port

R Handle on right side when facing inlet port

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


8670/71/74 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 50 gpm (190 L/min)
Pressures to 1200 psi (80 bar)
Port sizes: 1-1/4"

Specifications

Features

Non-Welded Construction (Gray Iron Head)


Vent Plugs
Changeover Handle with Latching Pin Mechanism
Filter Element Change Instruction Plate
Forged Steel Bowls
Commuter Valve (To Repressurize Idle Side After Element Change)
O-Ring Seals Throughout
Filter "In-Service" Pointer
Differential Pressure Device (Optional)
Ultipor® III Element
Drain Plug

Maximum Acceptable Working Pressure:


1200 psi (80 bar)

Typical Burst Pressure:


5500 psi (380 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 65 lbs. (29 kg)
T length– 75 lbs. (33.5 kg)
U length– 85 lbs. (38 kg)

Filter Element Collapse Pressure:


9600– 290 psid (20 bar)
9601– 3000 psid (207 bar)
4704–150 psid (10 bar)
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.
Element Pressure Drop Factor.
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Ordering Information

Assembly P/N: H 867


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC F
Table2 Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

Table 1: Seal Options

Code Seals

H Nitrile

Z Fluorocarbon

Table 2: Element Options

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid (high collapse)

4 9604 150 psid (coreless)


Table 3: Port Options

Code Description

A20 1-1/4" SAE J514 straight thread

D20 1-1/4" Flange SAE J518c-code 61

Table 4: Filter Element Options

Code ßX 200 ßx(c) = 1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

* 8671 only.

Table 5: Length Options*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

Table 6: Bypass Valve Options

Code Description

A* 25 psid bypass 8670/8674 only

B 50 psid bypass 8670/8674 only

W Non-bypass 8670 to 120 psi max.


8671 to 1200 psi max.
Not available for 8674.

* A valve-25 gpm max flow.

Table 7: Differential Pressure Device Options


Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M 'T' type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


9685 Series Service Bypass Filter Assemblies

Description

Flows to 65 gpm (250 L/min)


Pressures to 6000 psi (400 bar)
Port sizes: 1-1/4"

Specifications

Features

Ductile Iron Head


Commuter Valve (To Repressurize After Element Change)
Bleed Valve
O-Ring Seals
Ultipor® III Element
Drain Port and Plug
Optional Differential Pressure Device
Stainless Steel Bypass Valve with Nylon Poppet (Not Shown)
Stainless Steel Ball Valve with PTFE Seats (Not Shown)
Change Over Handle with Latching Pin Mechanism
All Non-Stainless Steel Parts Corrosion Protected

Maximum Acceptable Working Pressure:


6000 psi (400 bar)

Fatigue Pressure Rating:


4000 psi (275 bar)

Typical Burst Pressure:


24,360 psi (1680 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 45 lbs. (21 kg)
T length– 50 lbs. (23 kg)
U length– 55 lbs. (25 kg)

Filter Element Collapse Pressure:


9600– 290 psid (20 bar)

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific
gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

Ordering Information

Assembly P/N: H 9685


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC 9600 F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.
TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

D Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

TABLE 3: PORT SIZE OPTIONS

Code Size Style Availability

20 1-1/4" All

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13
U 16

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

L 58 psid

TABLE 7: Differential Pressure Device Options

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Bleed plug and seal in place of indicator

All differential pressure devices for the 9685 set at 44 psid.

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


4740/41/44 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 90 gpm (340 L/min)
Pressures to 6500 psi (450 bar)
Port sizes: 1-1/2"

Specifications

Features

Open Center Transfer Valve 3-Way Ball Type


Low Torque Handle
O-Ring Seals
Optional Differential Pressure Devices
Bleed Valves
Commuter Valve
Ultipor® III Element

Maximum Acceptable Working Pressure:


6500 psi (450 bar)

Fatigue Pressure Rating:


5800 psi (400 bar) with stainless steel indicator

Typical Burst Pressure:


23,200 psi (1600 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 114 lbs. (52 kg)
T length– 120 lbs. (55 kg)
U length– 131 lbs. (60 kg)

Filter Element Collapse Pressure:


9600-290 psid (20 bar)
9601-3000 psid (207 bar)
4704-150 psid (10 bar)

Materials:
–Ductile iron head
–Forged steel bowls

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop


using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific
gravity.

Figure 2. Bypass Valve Pressure


Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to
specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12


13" 0.32 0.08

16" 0.25 0.07

Ordering Information

Assembly P/N: H 474 24


Table1 Table2 Table3 Table4 Table5 Table6 Table7

Element P/N: HC F
Table2 Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

9601 3000 psid


1
(high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT OPTIONS

Code Port Style

A SAE J514 straight thread

D* Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

*D ports rated at 3000 psi (207 bar).

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12
KT 25 22

DP* 3 5

DT* 17 15

* 4741 only.

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

B 50 psid-4740/44 only

W Non-bypass-4741 only

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure
above 3000 psi, stainless steel indicators are necessary. Designate with
an ‘H’ in model code (e.g., PH, DH, etc.).
© Copyright Pall Corporation

Visit us on the Web at www.pall.com


6220 Series Filter Assembies

Description

Flows to 40 gpm (150 L/min)


Pressures to 150 psi (10 bar)
Port size: 1"

Specifications

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Maximum Operating Pressure:


150 psi (10 bar)

Typical Burst Pressure:


1200 psi (83 bar)

Filter Element Collapse Pressure:


290 psid (20 bar) minimum

Fluid Compatibility:
Petroleum oils, water glycols, water-oil emulsions, and HWCF.
Fluorocarbon seals required for industrial phosphate esters, diesters, and specified synthetics. 140°F (60°C)
max in water containing fluids.

Materials of Construction:
Aluminum alloy head, cover and canister

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Element Pressure Drop Factor.


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

6200 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT
4" 1.1 0.56 0.30 0.19 0.14

8" 0.53 0.27 0.15 0.10 0.07

Ordering Information

Assembly P/N: H 6220 A 16 B


Table1 Table2 Table3 Table4

Element P/N: HC 6200 F


Table2 Table3 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: LENGTH OPTIONS*

Assembly Code Element Code** Assembly Dry Wt. (lbs.)

R 4 2.2

S 8 2.4

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 4: P DEVICE OPTIONS

Code P Option H Dim.

G Pressure gauge (0-150 psi) 1.25" (32 mm)

B Plugged 1/8" NPT gauge port supplied 0.5" (12 mm)

8 Electrical absolute pressure switch. 2.7" (69 mm)


Electrical ratings suffix 24 volts DC–24 DC
220 volts AC-220 AC
© Copyright Pall Corporation

Visit us on the Web at www.pall.com


6300 Series Filter Assemblies

Description

Flows to 120 gpm (450 L/min)


Pressures to 250 psi (17 bar)
Port sizes: 1-1/4" and 1-1/2"

Specifications

Maximum Acceptable Working Pressure:


250 psi (17 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
250 psi (17 bar)

Typical Burst Pressure:


1200 psi (83 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 18.5 lbs. (8.4 kg)
T length– 20.0 lbs. (9.1 kg)
U length– 23.5 lbs. (10.7 kg)
V length– 27.0 lbs. (12.3 kg)

Filter Element Collapse Pressure:


150 psid (10 bar)

Caution:
120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
6300 Series Element P factor (psid/gpm)

Length DP DN DS DT

8" 0.29 0.18 0.13 0.09

13" 0.19 0.10 0.08 0.07

16" 0.14 0.08 0.06 0.05

26" 0.11 0.05 0.04 0.03

Ordering Information

Assembly P/N: H 6300


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6300F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"
TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

V 26

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout


LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings.


16 psid with "A" and "8" bypass valve.
35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see
Table 2) except that "A" style secondary port is used with "D" style main
inlet port.

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 3/4"

L Left side* 3/4"

B Both 3/4"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main
inlet port (See Table 2), except that "A" style auxiliary port(s) is used
with "D" style main inlet port.

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


6400 Series Filter Assemblies

Description

Flows to 200 gpm (755 L/min)


Pressures to 250 psi (17 bar)
Port sizes: 1-1/2" and 2"

Specifications

Maximum Acceptable Working Pressure:


250 psi (17 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
250 psi (17 bar)

Typical Burst Pressure:


1200 psi (83 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
S length– 22.5 lbs. (10.2 kg)
T length– 23.7 lbs. (10.8 kg)
U length– 25.0 lbs. (11.3 kg)
V length– 31.0 lbs. (14.1 kg)

Filter Element Collapse Pressure:


150 psid (10 bar)

Caution:
120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
6400 Series Element P factor(psid/gpm)

Length DP DN DS DT

8" 0.26 0.16 0.12 0.08

13" 0.17 0.09 0.07 0.06

16" 0.13 0.07 0.05 0.04

26" 0.10 0.05 0.04 0.03

Ordering Information

Assembly P/N: H 6400


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6400F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

20 1-1/4"

24 1-1/2"
TABLE 4: FILTER Element OPTIONS

Code ßx 200 ßx(c)=1000

DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

S 8

T 13

U 16

V 26

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector


ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator

PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings.


16 psid with "A"and "8" bypass valve.
35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1-1/4"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see
Table 2).

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 1"

L Left side* 1"

B Both 1"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main
inlet port (See Table 2), except that "A" style auxiliary port(s) is used
with "D" style main inlet port.

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


6500 Series Filter Assemblies

Description

Flows to 300 gpm (1135 L/min)


Pressures to 250 psi (17 bar)
Port sizes: 2" and 2-1/2"

Specifications

Maximum Acceptable Working Pressure:


250 psi (17 bar)

Fatigue Pressure Rating:


(NFPA/T2.6.1-1974 category 2/90)
250 psi (17 bar)

Typical Burst Pressure:


1200 psi (83 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:
T length– 26.0 lbs. (11.8 kg)
U length– 30.0 lbs. (13.6 kg)
V length– 35.5 lbs. (16.1 kg)

Filter Element Collapse Pressure:


150 psid (10 bar)

Caution:
120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.
6500 Series Element P factor (psid/gpm)

Length DP DN DS DT

13" 0.14 0.08 0.06 0.05

16" 0.11 0.06 0.04 0.04

26" 0.08 0.04 0.03 0.02

Ordering Information

Assembly P/N: H 6500


Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Element P/N: HC 6500F


Table4 Table5 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: PORT STYLE OPTIONS

Code Port Style

A SAE J514 straight thread

B NPT

D Flange SAE J518c-Code 61

TABLE 3: INLET PORT SIZE OPTIONS

Code Size

32 2"

40 2-1/2"

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000


DP 3 5

DN 6 7

DS 12 12

DT 25 22

TABLE 5: LENGTH OPTIONS*

Assembly Code Element Code**

T 13

U 16

V 26

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

A 25 psid

B 50 psid

W Non-bypass

8 25 psid with ABFV*

9 50 psid with ABFV

V Non-bypass with ABFV

* ABFV- Anti-backflow valve.

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

PM Visual indicator with thermal lockout

DM Visual indicator with no thermal lockout

LL Electrical switch (SPDT) with 6" leads

TL Electrical switch with DIN connector

ML ‘TL’ type switch with matching wiring cap

SL Electrical switch with MS receptacle

BL Plug in place of indicator


PL Same as PM but with plastic body

DL Same as DM but with plastic body

Indicator and switch pressure settings


16 psid with "A"and "8" bypass valve
35 psid with "W," "V," "B," and "9" option.

TABLE 8: SECONDARY PORT OPTIONS

Code Port Option Port Size

S Port machined 1-1/2"

N Non-machined -

Port opposite main inlet in style consistent with main inlet port (see
Table 2).

TABLE 9: AUXILIARY PORT OPTIONS

Code Port Option Port Size

R Right side* 1-1/4"

L Left side* 1-1/4"

B Both 1-1/4"

N Non-machined -

* Left or right side when facing inlet port. Port style consistent with main
inlet port (See Table 2).

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


301/381 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 150 gpm (570 lpm), 301 Series; 300 gpm (1135 lpm), 381 Series
Pressures to 675 psig (46.5 bar)
Port Sizes: 2", 3", and 4"
ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure:


Class 150: 260 psig (18 bar);
Class 300: 675 psig (46.5 bar) at 200°F (93°C)

Temperature Range:
-20°F to 200°F (-29°C to 93°C);
140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


150 psid (10 bar)

Hydrostatic Test Pressure:


Class 150: 390 psig (26.9 bar)
Class 300: 1013 psig (69.8 bar)

Materials of Construction:
Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless
steel 304L valve ball and stem on “D” duplex model
Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve
body, valve ball, and stem on “D” duplex model

Finish:
Interior finish: coated with rust preventative
Permanent cores: tin plated
Exterior finish: two coats of zinc primer on carbon steel option

Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1,
including latest addenda.

Dimensional Drawings
Dimensions (301 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO2 7.88 3.94 19.69 6.00 8.66 5.12 6.63 46.06 59.06

J03 7.88 5.12 20.87 6.00 11.42 6.89 6.63 46.06 59.06

Dimensions (381 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO3 10.00 5.12 25.12 8.00 11.42 6.89 8.63 N/A 61.75

J04 10.00 5.90 25.90 6.00 13.78 7.28 8.63 N/A 61.75

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
301 Series with 8904 Elements

381 Series with 8314 Elements

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.10 0.044 0.037 0.028 0.019

39" 0.062 0.029 0.024 0.018 0.013

8314 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

39" 0.034 0.018 0.015 0.012 0.008

Maximum Clean Element Pressure Drop for Bypass Valves


Calculated clean element pressure drop should not exceed the values listed in the table for the selected
bypass valve option.

Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’


Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Ordering Information

Assembly P/N: H 3
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement
Element P/N: HC 8904F
Table5 Table6 Table1

HC 8314F
Table5 Table6 Table1
Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

01 8904 element

81 8314 element

*Housings accept a single element.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex

TABLE 4: PORT OPTIONS

Code Port Availability

J02 2" ANSI B16.5 class 150 flanges 301 series

J03 3" ANSI B16.5 class 150 flanges 301 and 381 series

J04 4" ANSI B16.5 class 150 flanges 381 series

N02 2" ANSI B16.5 class 300 flanges 301 series

N03 3" ANSI B16.5 class 300 flanges 301 and 381 series

N04 4" ANSI B16.5 class 300 flanges 381 series


TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 301 series only

X 39 301 and 381 series

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid

B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator

P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option
7 Carbon steel

9 304L stainless steel

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


307/387 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 900 gpm (3406 lpm), 307 Series; 1500 gpm (5678 lpm), 387 Series
Pressures to 675 psig (46.5 bar)
Port Sizes: 4" and 6"
ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure:


Class 150: 260 psig (18 bar);
Class 300: 675 psig (46.5 bar) at 200°F (93°C)

Temperature Range:
-20°F to 200°F (-29°C to 93°C);
140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


150 psid (10 bar)

Hydrostatic Test Pressure:


Class 150: 390 psig (26.9 bar)
Class 300: 1013 psig (69.8 bar)

Materials of Construction:
Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless
steel 304L valve ball and stem on “D” duplex model
Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve
body, valve ball, and stem on “D” duplex model

Finish:
Interior finish: coated with rust preventative
Permanent cores: tin plated
Exterior finish: two coats of zinc primer on carbon steel option

Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1,
including latest addenda.

Dimensional Drawings
Dimensions (307 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO4 11.85 5.90 29.60 8.00 13.78 7.28 14.00 50.06 63.06

J06 11.85 11.81 35.50 6.50 23.62 8.46 14.00 59.90 72.90

Dimensions (387 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO6 17.85 11.81 47.50 8.00 23.62 8.46 20.00 N/A 72.75

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
307 Series with 8904 Elements

387 Series with 8314 Elements

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

*8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.014 0.006 0.005 0.004 0.003

39" 0.009 0.004 0.003 0.003 0.002

*8314 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

39" 0.0049 0.0026 0.0021 0.0017 0.0011

*Factors listed above have been adjusted to represent the total number of elements per housing.
Maximum Clean Element Pressure Drop for Bypass Valves
Calculated clean element pressure drop should not exceed the values listed in the table for the selected
bypass valve option.

Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’


Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Ordering Information

Assembly P/N: H 3
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement
Element P/N: HC 8904F
Table5 Table6 Table1

HC 8314F
Table5 Table6 Table1

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

07 8904 element

87 8314 element

*Housings accept 7 elements.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex

TABLE 4: PORT OPTIONS


Code Port Availability

J04 4" ANSI B16.5 class 150 flanges 307 series

J06 6" ANSI B16.5 class 150 flanges 307 and 387 series

N04 4" ANSI B16.5 class 300 flanges 307 series

N06 6" ANSI B16.5 class 300 flanges 307 and 387 series

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 307 series only

X 39 307 and 387 series

* Use Code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid

B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator


P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option

7 Carbon steel

9 304L stainless steel

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


303/383 Series ASME Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 400 gpm (1510 lpm), 303 Series; 700 gpm (2650 lpm), 383 Series
Pressures to 675 psig (46.5 bar)
Port Sizes: 2", 3", 4" and 6" ANSI Flange Connections

Specifications

Maximum Acceptable Working Pressure:


Class 150: 260 psig (18 bar);
Class 300: 675 psig (46.5 bar) at 200°F (93°C)

Temperature Range:
-20°F to 200°F (-29°C to 93°C);
140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


150 psid (10 bar)

Hydrostatic Test Pressure:


Class 150: 390 psig (26.9 bar)
Class 300: 1013 psig (69.8 bar)

Materials of Construction:
Carbon steel option: carbon steel housing, nozzles, and flanges; carbon steel transfer valve body with stainless
steel 304L valve ball and stem on “D” duplex model
Stainless steel option: 304L stainless steel housing, nozzles, and flanges; 316 stainless steel transfer valve
body, valve ball, and stem on “D” duplex model

Finish:
Interior finish: coated with rust preventative
Permanent cores: tin plated
Exterior finish: two coats of zinc primer on carbon steel option

Housings are designed, manufactured, and stamped in accordance with ASME BPVC Section VIII Div. 1,
including latest addenda.

Dimensional Drawings
Dimensions (303 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO2 10.00 3.94 23.94 8.00 8.66 5.12 10.75 50.06 63.06

J03 10.00 5.12 25.12 8.00 11.42 6.89 10.75 50.06 63.06

J04 10.00 5.90 25.90 8.00 13.78 7.28 10.75 50.06 63.06

Dimensions (383 Series)

Port ‘A’ Simplex ‘B’ Duplex ‘C’ Duplex ‘D’ ‘E’ ‘F’ Duplex ‘G’ ‘L’ V- ‘L’ X-
Size Only Only Only Only Length Length

JO4 14.10 5.90 34.20 8.00 13.78 7.28 16.00 N/A 61.75

J06 14.10 11.81 40.00 8.00 23.62 8.46 16.00 N/A 61.75

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
303 Series with 8904 Elements

383 Series with 8314 Elements

Element Pressure Drop Factor.


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

*8904 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

26" 0.033 0.015 0.012 0.009 0.006

39" 0.021 0.010 0.008 0.006 0.004

*8314 Series Element P factor (psid/gpm)


Length KZ KP KN KS KT

39" 0.011 0.006 0.005 0.004 0.003

*Factors listed above have been adjusted to represent the total number of elements per housing.

Maximum Clean Element Pressure Drop for Bypass Valves


Calculated clean element pressure drop should not exceed the values listed in the table for the selected
bypass valve option.

Bypass ‘E’ ‘F’ ‘D’ ‘A’ ‘B’ ‘W’


Option (5 psid) (12 psid) (18 psid) (25 psid) (50 psid) (non-bypass)

Max. Clean P 1 psid 2 psid 3 psid 4 psid 8 psid 15% of max P

Ordering Information

Assembly P/N: H 3
Table1 Table2 Table3 Table4 Table5 Table6 Table7 Table8 Table9

Replacement
Element P/N: HC 8904F
Table5 Table6 Table1

HC 8314F
Table5 Table6 Table1
Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: HOUSING OPTION*

Code Option

03 8904 element

83 8314 element

*Housings accept 3 elements.

TABLE 3: HOUSING STYLE OPTIONS

Code Style

S Simplex - ports on same side

D Duplex
TABLE 4: PORT OPTIONS

Code Port Availability

J02 2" ANSI B16.5 class 150 flanges 303 series

J03 3" ANSI B16.5 class 150 flanges 303 series

J04 4" ANSI B16.5 class 150 flanges 303 and 383 series

J06 6" ANSI B16.5 class 150 flanges 383 series

N02 2" ANSI B16.5 class 300 flanges 303 series

N03 3" ANSI B16.5 class 300 flanges 303 series

N04 4" ANSI B16.5 class 300 flanges 303 and 383 series

N06 6" ANSI B16.5 class 300 flanges 383 series

TABLE 5: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 6: LENGTH OPTIONS*

Assembly Code Element Code** Availability

V 26 303 series only

X 39 303 and 383 series

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 7: BYPASS VALVE OPTIONS

Code Cracking Pressure

A 25 psid
B 50 psid

D 18 psid

E 5 psid

F 12 psid

W Non-bypass

TABLE 8: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

O No indicator

B Bleed plug and seal in place of indicator

P Visual indicator with thermal lockout

S Electrical switch with MS receptacle

L Electrical switch with 6" leads

V Electrical/visual indicator

TABLE 9: HOUSING MATERIAL OPTIONS

Code Option

7 Carbon steel

9 304L stainless steel

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


2544 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 120 gpm (454 L/min)
Pressures to 500 psi (34.5 bar)
Port sizes: 1-1/4" and 1-1/2"

Specifications

Maximum Acceptable Working Pressure:


500 psi (34.5 bar)

Bypass Valve:
25 psid (1.724 bar)

Seals:
Nitrile–Compatible with petroleum oils, water-oil emulsions and water-glycol

Temperature Range:
-45°F to 225°F (-43°C to 107°C)

Filter Element Collapse Pressure:


150 psid (10 bar)

Materials:
– Aluminum head and nipple
– Aluminum and steel bypass valve
– Carbon steel canister and core assembly

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

2544 Series Element P factor (psid/gpm)

Length KP KN KS KT

9" 0.12 0.08 0.06 0.05

19" 0.06 0.04 0.03 0.02

Ordering Information

Assembly P/N: HH 2544 A


Table1 Table2 Table3 Table4 Table5 Table6

Element P/N: HC 2544F H


Table2 Table3

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: PORT OPTIONS

Code Port Option

A20 1-1/4" SAE straight thread O-ring boss per SAE J514H

A24 1-1/2" SAE straight thread O-ring boss per SAE J514H

B20 1-1/4" NPT

B24 1-1/2" NPT


TABLE 2: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KP 3 5

KN 6 7

KS 12 12

KT 25 22

TABLE 3: LENGTH OPTIONS*

Assembly Code Element Code**

S 9

U 19

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 4: INDICATOR OPTIONS

Code Device

G Pressure gauge (25 psi), other port plugged (1/8" NPT)

8 Pressure switch (15 psi) N.O. S.P.S.T. screw terminals, other


port plugged (1/8" NPT)

2 Pressure gauge (25 psi) and pressure switch (15 psi) N.O.
S.P.S.T. screw terminals

B Port plugs (1/8" NPT)

TABLE 5: SECONDARY PORT OPTIONS

Code Description

OMIT No secondary port

20* 1-1/4" port (same port style as primary port)

* Available only with A24 and B24 primary ports.


TABLE 6: OUTLET OPTIONS

Code Description

OMIT 1-5/8" discharge

D Diffuser with adapter

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


4750/51/54 Series Filter Assemblies

Description

Featuring Coreless Element Technology


Flows to 90 gpm (340 L/min)
Pressures to 6500 psi (450 bar)
Port sizes: 1-1/2"

Specifications

Features

Low Torque Handle


Commuter Valve
Optional Differential Pressure Devices
Bleed Valves
O-Ring Seals
Ultipor® III Element
Open Center Transfer Valve 3-Way Ball Type

Maximum Acceptable Working Pressure:


6500 psi (450 bar)

Fatigue Pressure Rating:


5800 psi (400 bar) with stainless steel indicator

Typical Burst Pressure:


23,200 psi (1600 bar)

Temperature Range:
Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Filter Element Collapse Pressure:


9600– 290 psid (20 bar)
9601– 3000 psid (207 bar)
4704– 150 psid (10 bar)

Materials:
–Ductile iron head
–Forged steel bowls

Dimensional Drawings
Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.


Housing Pressure drop is directly proportional to specific gravity.

Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.

Element Pressure Drop Factor.


Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

9600/4704 Series Element P factor (psid/gpm)

Length KZ KP KN KS KT

8" 0.46 0.20 0.17 0.12 0.09

13" 0.27 0.12 0.10 0.07 0.05

16" 0.20 0.09 0.07 0.05 0.04

9601 Series Element P factor (psid/gpm)

Length DP DT

8" 0.52 0.12

13" 0.32 0.08

16" 0.25 0.07

Ordering Information

Assembly P/N: H 475 24


Table1 Table2 Table3 Table4 Table5 Table6 Table7
Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS

Code Seals

H Nitrile

Z Fluorocarbon

TABLE 2: ELEMENT OPTIONS

Assembly Code Element Code Rating

0 9600 290 psid (standard)

1 9601 3000 psid


(high collapse)

4 4704 150 psid (coreless)

TABLE 3: PORT OPTIONS

Code Port Style

A SAE J514 straight thread

D* Flange SAE J518c-Code 61

E Flange SAE J518c-Code 62

*D ports rated at 3000 psi (207 bar).

TABLE 4: FILTER ELEMENT OPTIONS

Code ßx 200 ßx(c)=1000

KZ <1 2.5

KP 3 5

KN 6 7

KS 12 12

KT 25 22

DP* 3 5

DT* 17 15

* 4751 only.

TABLE 5: LENGTH OPTIONS*


Assembly Code Element Code**

S 8

T 13

U 16

* Use code in second column for element part no.


** Nominal length in inches.

TABLE 6: BYPASS VALVE OPTIONS

Code Description

B 50 psid-4750/54 only

W Non-bypass-4751 only

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS

Code Description

P Visual indicator with thermal lockout

D Visual indicator with no thermal lockout

L Electrical switch (SPDT) with 6" leads

T Electrical switch with DIN connector

M ‘T’ type switch with matching wiring cap

S Electrical switch with MS receptacle

V Combined visual/electrical with DIN connector

B Plug in place of indicator

2 ‘P’ and ‘L’

3 ‘P’ and ‘S’

Note: Above indicators fatigue rated at 3000 psi. For cyclic pressure
above 3000 psi, stainless steel indicators are necessary. Designate with
an ‘H’ in model code (e.g., PH, DH, etc.).

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


Ultipleat SRT Filter Assemblies

Description

Ordering Information

© Copyright Pall Corporation

Visit us on the Web at www.pall.com


Data Sheet IM2035EN

2035 Series
High Pressure Filter Assemblies

Features
• High collapse 4500 psid (310 bard) filter element using
Rigimesh® stainless steel medium
• Flows to 38 lpm (10 gpm)
• Port sizes: 3⁄8" NPT, 1⁄2" NPT
Notes and Specifications
Maximum working pressure:
6,000 psi (413 bar)
Typical burst pressure:
min. 24,000 psi (1655 bar)
Temperature rating:
-10°F (-23°C) to 225°F (107°C)
Materials of Construction:
Head and Body: Stainless Steel
Seal material: PTFE encapsulated fluorocarbon
(Nitrile and Chloroprene also
available)
Filter element
collapse pressure: 4500 psid (310 bard)
Element
construction: Rigimesh all stainless steel (no resin
binders) medium, stainless steel
end caps
Seal Material: Chloroprene, Nitrile,
PTFE encapsulated fluorocarbon

Pressure Drop Information


Housing Pressure Drop Element Pressure Drop
Fluid at 14.3 cSt (75 SUS), 0.88 S.G. Fluid at 14.3 cSt (75 SUS), 0.88 S.G.
Housing pressure drop is directly proportional to specific Correct for other fluids by multiplying new viscosity in
gravity. cSt/14.3 (SUS/75) x new S.G./0.88.
Flow (lpm) Flow (lpm)
0 15 30 45 60 0 10 20 30
50 10
3
/8˝ port
0.6
40 2.8 8
1
0.5
/2˝ port
30 6 0.4

20 1.4 4 NK 0.3
0.2
∆P (psid)

∆P (psid)
∆P (bar)

∆P (bar)

10 2 NJ 0.1

0 0 0 0
0 4 8 12 16 0 2.5 5 7.5 10
Flow (gpm) Flow (gpm)
Dimensional Drawings Part Numbers/Ordering Information
H ◆ 2035 ▼ ■ ● ✖ v ❚ (e.g., HZ2035B06NKRWE1)
FRONT VIEW (1)(2)
Code Seal Code Bypass Valve
◆ Material ✖ Type
.17
1.05 (0.28 with BH plug) H Nitrile W Non-bypass,
P Chloroprene (100 psid
indicator setting
Z PTFE where equipped)
encapsulated
fluorocarbon
v
Code ∆P Device
3.85 Options
Code Type of
▼ Port E visual, 6,000 psi
∅3.97 rated
6.67 B06 3
⁄8" NPT
B08 1
⁄2" NPT 0 No port
BH Plug
Code Filter Media
∅2.97 ■ Grade Options
.33 Code Additional
NK 5 µm ❚ Options
NJ 10 µm Omit None
++ Housing only
1” HEX 1 Mounting
bracket
Code Length assembly
TOP VIEW (1)(2) ● (nominal)
R 4"
3.00
1.102 1.102

4X .375-16 LNC-2B
THREAD .70 DEEP
Rigimesh Element Part Number
2.75 HC2035E ■ 4 ◆ Y923 (e.g., HC2035ENK4ZY923)

.984 .75
Code Filter Media Code Seal
■ Grade Options ◆ Material
INTLET
OUTLET

.984 NK 5 µm(3) H Nitrile


OUTLET INLET
NJ 10 µm(3) P Chloroprene
Z PTFE
encapsulated
fluorocarbon
1.735 1.735

1 Dimensions are in inches.


2 3.0" required for element removal.
3 98% efficiency.

USA
25 Harbor Park Drive
Port Washington, NY 11050
+1 888 333 7255 (toll free in U.S. only) Visit us on the Web at www.pall.com
+1 516 484 3600 phone Pall Corporation has offices and plants throughout the world in locations including:
+1 516 484 6247 fax Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India,
Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands, New Zealand,
United Kingdom Norway, Poland, Puerto Rico, Russia, Singapore, South Africa, Spain, Sweden, Switzerland,
Europa House, Havant Street Taiwan, Thailand, United Kingdom, United States, and Venezuela. Distributors are located in all
Portsmouth PO1 3PD major industrial areas of the world.
Hampshire, England
+44 (0) 23 9230 3303 phone
+44 (0) 23 9230 2507 fax
m&e_sales@pall.com email

© Copyright 2007, Pall Corporation. Pall, , and Rigimesh are trademarks of Pall Corporation. ® Indicates a Pall
trademark registered in the USA. is a service mark of Pall Corporation.

Bulletin #IM2035EN 2/07


2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 1

Data Sheet PM&E 2050/2060/2070-A

2050/2060/2070 Series
High Pressure Filter Assemblies

Features
• Ultipor ® III or Rigimesh® stainless steel media
• Flows to 75 lpm (20 gpm)
• Pressures:
2050 Series: 690 bar (10,000 psi)
2060 Series: 1034 bar (15,000 psi)
2070 Series: 1379 bar (20,000 psi)
• Port sizes: 3/8″, to 3/4″
Notes and Specifications
Maximum Working Pressure:
2050 series: 690 bar (10,000 psi)
2060 series: 1000 bar (14,500 psi)
2070 series: 1379 bar (20,000 psi)
Proof Pressure:
2050 series: 1034 bar (15,000 psi)
2060 series: 1500 bar (21,750 psi)
2070 series: 2068 bar (30,000 psi)
Typical Burst Pressure:
2050 series: 2758 bar (40,000 psi)
2060 series: 3490 bar (50,750 psi) 2050, 2060, and 2070 series filter housings
2070 series: 5516 bar (80,000 psi)
Temperature Range: Nitrile seals: -43˚C to 107˚C
2070 Series
(-45˚F to 225˚F)
Fluorocarbon Seals: Flow (lpm)
-29˚C to 120˚C (–20˚F to 250˚F) 0 10 20 30 40 50 60
60˚C (140˚F) maximum in HWCF 50
3.0
or water glycol fluids with 40
Ultipor III media V06
30 V09 2.0
Filter Element W12
Collapse Pressure: 9020 series: 20 bar (290 psid); 20 V12
P (psid)

P (bar)
9021 series: 207 bar (3000 psid); 1.0
10
310 bar (4500 psid) with Rigimesh
all stainless steel media 0 0
(NK or NJ options) 0 2 4 6 8 10 12 14 16
Materials of Construction: Stainless steel; titanium bowl Flow (gpm)
(2070/71)
Element Construction: Ultipor III: Inorganic fibers impreg-
nated and bonded with epoxy Element Pressure Drop
resins; stainless steel hardware. Multiply actual flow rate times factor to determine pressure drop
Rigimesh: All stainless steel (no with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by
resin binders) multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.
Note: factors are per 1000 lpm and per 1 gpm.
Pressure Drop Information
Figure 1. Housing pressure drop using fluid with 0.9 S.G. 9020 Series Filter Elements — bar/1000 lpm (psid/gpm)
Housing pressure drop is directly proportional to specific gravity.
Length
2050/2060 Series
Code KZ KP KN KS KT
Flow (lpm)
4 34.61 (1.90) 14.94 (0.82) 9.84 (0.54) 6.38 (0.35) 3.83 (0.21)
0 10 20 30 40 50 60 70
50 8 17.49 (0.96) 7.47 (0.41) 4.92 (0.27) 3.28 (0.18) 2.00 (0.11)
3.0
40 9021 Series Filter Elements — bar/1000 lpm (psid/gpm)
V06 B06
30 V09 2.0 Length
20 Code DP DS/NK DT/NJ
Δ P (psid)

Δ P (bar)

1.0 4 49.37 (2.71) 36.54 (0.53) 12.39 (0.68)


10 A, B, C, W
08/12
1 8 24.59 (1.35) 17.24 (0.25) 6.19 (0.34)
0 0
0 2 4 6 8 10 12 14 16 18 20
Flow (gpm)
2050-2060-2070glr1.qxd 12/19/05 2:29 PM Page 2

249.94 mm/9.84 in (R-length)


345.44 mm/13.60 in (S-length)
25.4 mm
Dimensional Drawings ‘H’ Dim. 1.00 in
Ref.

2X
10.31 mm Visual
22.10 mm Ø.406 in indicator 1.19 Hex.
.87 in Explosion 101 mm
INLET OUTLET proof indicator 4 in

95 mm
57.15 mm ‘H’ Dim. 3.75 in
2.25 in 150 Ref. mm Ref. Element change
5.9 Ref. in 104.8 mm
4.125 in
V12 port 111.4 mm
92.20 mm option only Ø4.385 in
Primary port 3.63 in
OUTLET location (2050/51 Mounting dimensions
and 2060/61 only) same as other options.

OUTLET

INLET
24.99 mm
30.23 mm
OUTLET
.984 in

INLET
1.19 in
24.99 mm
.984 in

69.85 mm
2.75 in Secondary port 4 X 3/8-16 UNC 2B Table 4: Filter Element Options Table 5: Length Options
location (2050/51 .70 deep
and 2060/61 only)
27.99 mm Code Bx(c) ≥ Element Housing Element Length (in)*
Ordering Information 1.102 in 1000 Series Code Code
KZ 3 9020 (Ultipor III) R 4 4
Assembly P/N:
KP 5 9020 (Ultipor III) S 8 8
H 20 T
KN 7 9020 (Ultipor III) * Nominal length
Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8
KS 12 9020 (Ultipor III)
Ultipor Element P/N:
KT 22 9020 (Ultipor III)
HC F Y923
DP 5 9021 (Ultipor III)
Table 2 Table 4 Table 5 Table 1
Table 1: Seal Options DS 12 9021 (Ultipor III)
Rigimesh Element P/N:
Code Seals DT 15 9021 (Ultipor III)
HC 9021 E
H Nitrile NK 5 µm* 9021 (Rigimesh)
Table 4 Table 5 Table 1
Z Fluorocarbon NJ 10 µm* 9021 (Rigimesh)

* 98% efficiency
Table 2: Series Options
Table 6: Bypass Valve Options
Housing Code Description Element Code
50 690 bar (10,000 psi) housing with 50 psi Code Valve Housing Series
bypass valve 9020 B 3.4 bar (50 psid ) 2050, 2060, 2070
60 1000 bar (14,500 psi) housing with 50 psi J 10 bar (150 psid ) 2051, 2061, 2071
bypass valve 9020
S 13.8 bar (200 psid ) 2051, 2061, 2071
70 1379 bar (20,000 psi) housing with 50 psi
bypass valve 9020 W Non-bypass, 100 psid indicator 2051, 2061, 2071*

51 690 bar (10,000 psi) 9021 N Non-bypass, 35 psid indicator 2051, 2061, 2071*

61 1034 bar (15,000 psi) 9021 * Note: 2071 series does not have indicator ports
71 1379 bar (20,000 psi) 9021
Table 7: Differential Pressure Indicator Options*
Table 3: Port Options Code Indicator ‘H’ Dim.
W Explosion proof 79 mm (3.1 in)
Code Port Series
E SST visual 28 mm (1.1 in)
A08 1/2″ SAE J514 straight thread 2050/51, 2060/61
0 No indicator port N/A
A12 3/4″ SAE J514 straight thread 2050/51
B SST port plug 3 mm (0.12 in)
B06 3/8″ NPT 2050/51, 2060/61
B08 1/2″ NPT 2050/51, 2060/61 *Notes:
B12 3/4″ NPT 2050/51 1. Select 2 indicator option codes per housing
C08 1/2″ BSP ISO 228 threads 2050/51, 2060/61 2. Enter indicator codes alphabetically; put “0” code after alpha code if applicable
3. 2070/71 series does not have indicator ports; enter “00” in part number
C12 3/4″ BSP ISO 228 threads 2050/51
V06 3/8″ medium pressure threaded 2050/51, 2060/61, 2070 Table 8: Mounting Bracket Options
V09 9/16″ medium pressure threaded 2050/51, 2060/61, 2070 Code Option
V12 3/4″ medium pressure threaded 2050/51, 2060/61, 2070 0 None
W12 3/4″ weld sockets 2050/51 1 Mounting bracket kit

Visit us on the Web at www.pall.com/m&e

New York – USA


+1 516 484 3600 telephone
+1 888 333 7255 toll free
+1 516 625 3825 fax

Portsmouth – UK
+44 (0)23 9230 3303 telephone © Copyright 2005, Pall Corporation. Pall, , Ultipor and Rigimesh are trademarks of Pall Corporation.
+44 (0)23 9230 2507 fax ® Indicates a Pall trademark registered in the USA. is a service mark of
m&e_sales@pall.com Pall Corporation.

You might also like