standard PLC ?
Risk assessment Describe the machine Identify the hazards Evaluate the risks
Define and
evaluate Design the architecture Implement a safety concept and
Risk reduction the safety measures of the safety functions put it into operation
(3-level method)
Risk reduction
START
YES No PLC
Risk reduced appropriately?
NO
needed
2 Technical measures
YES
Risk reduced appropriately?
NO
YES
Risk reduced appropriately?
NO
PL a
Standard MTTFd
components PL b low
medium
high
WELL tried PL c
components !!
PL d
PL e
Standard
components
WELL tried
components !!
??
Intern © Siemens AG 2016
DF FA S MP PLC 2
With Sistema PL can be calculated
STD CPU
STD DI
STD DO
IEC 62061
• applicable for all electrical and electronical systems with any architecture.
• SIL 1 up to 3
• programmable logic controller (PLC etc) have to fulfil IEC 61508
EN ISO 13849-1
• applicable for hydraulic, pneumatic and electromechanical systems without
restrictions.
• applicable for programmable electronic only with restrictions
• certain architecture
• up to PL d resp. SIL 2
• programmable logic controller for PL e (SPS etc) have to fulfil
IEC 61508
• calculation concept of ISO 13849-1 based on predefined architectures