You are on page 1of 2

All glass profile system (PSF)

Compatible with 100 mm and 140 mm


LB Compatibility of profile systems
drive systems
SL drive systems are compatible with our profile systems, thereby ensuring a perfect fit with any metal structure design.

SL - ONE DOOR SYSTEM


Single-leaf and bi-parting sliding doors
With side door panel, protection leaf
Full length bottom rail or Cog for easy suspension into support

FOR ALL APPLICATIONS


fixed-point guide profile
Emergency-exit function (redundant)

SL 35
Low-profile frame system (PSA) LB 30 SL 45
Compatible with 100 mm, 140 mm drive
system and 140 mm telescopic configuration Running surface: hard-anodised
Reinforced aluminum track profile
Single-leaf and bi-parting sliding doors Running surface: hard-anodised
Two- and four-leaf telescopic sliding
doors Compact - all glass (PSF) Standard - all glass (PSF) The highly versatile SL sliding door drives provide
With side door panel, protection leaf SL 35-C SL 35-S
205 175 compatibility with practically any application.
Full length bottom rail or fixed point
guide Suitability for door leaf weights of up to 240 kg,
Emergency-exit function (redundant) applications and profile systems

100

140
The drive system for all the Gilgen profile systems
Standard profile system (PSXP) LB 40 Single-leaf and bi-parting sliding doors
Compatible with 100 mm, 140 mm drive
system and 140 mm telescopic configuration Two- and four-leaf telescopic sliding doors
Single-leaf and bi-parting sliding doors With side door panel, glazed overhead panel and
Compact - low-profile frame (PSA) Standard - low-profile frame (PSA) Telescopic - low-profile frame (PSA)
Two- and four-leaf telescopic sliding SL 35-C SL 35-S SL 35-T protection leaf
doors 205 175 100 175
With side door panel, protection leaf PSF, PSA, PSXP, PST profile systems and leaves supplied
Full length bottom rail, with or without by others
drainage / fixed point guide

100
Emergency-exit function (redundant Emergency-exit function (redundant configuration)

140
140
configuration)
Universal interfaces for trouble-free extension of the system
Certified overall system (EN 16361)
RC2 / RC3 break-in prevention design All the features, from lightweight, all glass designs to robust
break-in prevention, are based on standard components
Compact - standard (PSXP) Standard - standard (PSXP) Telescopic - standard (PSXP) Certified overall systems matched to the design of each
Thermally insulated profile system (PST) LB 40
SL 35-C SL 35-S / SL 45-S SL 35-T / SL 45-T (with reinforcement bracket)
Compatible with 100 mm and 140 mm building
205 175 100 175
drive system and 140 mm telescopic PR OVED
configuration AP Gilgen CAN-Bus sensors as well as sensors supplied
45

V
ION


by others
Single-leaf and bi-parting sliding doors ILL S

100
M

U N IT
3 CLE

140

140
Two- and four-leaf telescopic sliding Battery BATPA
doors CY

R
SL

O
High-level thermal insulation / SLI O Carlock running carriage locking integrated in the drive
DIN G D
low „U“ value mechanism
With side door panel, protection leaf - CARLOCK (Standard and Redundant configuration)
Full length bottom rail, with or without
Compact - thermally insulated (PST) Standard - thermally insulated (PST) Telescopic - thermally insulated (PST) - CARLOCK-FS (Fail Safe, Fail Secure, Emergency exit and
drainage / fixed point guide
SL 35-C SL 35-S / SL 45-S SL 35-T / SL 45-T (with reinforcement bracket)
Emergency-exit function (redundant
Rescue access, Longlife)
configuration) 62,5 205 62,5 175 62,5 100 175
FLUVERI multi-point locking automatic / manual (PSXP / PST)
Certified overall system (EN 16361)
RC2 / RC3 break-in prevention design Door and lock monitoring TUWE VdS
©GILGEN | 10/2021 | P 08.01.06

100

140
Air curtain control

140
Control pillar

Member of the Group www.gilgendoorsystems.com


SL drive system Gilgen SL – smart and timeless
Everything at a glance Simple, slimline and functional

Combinations Drive systems


Low-noise design with optimised running carriage
The integrated modular system forms the basis of our customised sliding door solutions
configuration
• Compatible with all door weights and applications
• Carefully matched components (profile system, drive mechanism, operational items, fittings) Running carriage designed to match performance
• Universal interfaces for trouble-free extension of the system Damped carrying roller system for quiet operation
• All the features, from lightweight, all glass designs to robust break-in prevention, are based on standard components
Easy adjustment of counter-pressure roller
• Certified overall systems matched to the design of each building
• Each door application is based on a single system 100 mm Compact 140 mm Standard 140 mm Heavy 140 mm Telescopic 140 mm Telescopic Easy door leaf adjustment
• Low-noise SL 35-C SL 35-S SL 45-S SL 35-T SL 45-T
Universal leaf suspension configuration compatible with all
Motor 150 kg profile systems
Per sliding door leaf (Telescopic 2 x 120 kg, 4 x 75 kg)   −  −
240 kg Automatic opening combines convenience
Per sliding door leaf (Telescopic 2 x 170 kg, 4 x 120kg) − −  −  with personal safety
Integrated CAN-bus sensors guarantee maximum personal
Controls Standard
safety and reliable functioning of the door
• EN 16005-tested
• USB interface for software update
• Gilgen sensor system operating via CAN bus, integrated into the drive casing
  −  − Emergency-exit function conforming to EN 16005 / DIN 18650

• Also compatible with conventional sensor systems


Redundant Safety and security – this future-oriented system offers
• Conforms to Performance Level ““d““ in accordance with EN 13849-1
• Connection of two SL motors also possible for DUAL function
  −  − security, while protecting property and preventing break-ins
Overall solutions tested to EN 16005 standards, with
Universal (standard & redundant) emergency-exit (redundant)
• Reinforced, switching power supply unit for dynamic operation
• Simplified spare parts handling (covering all the functions)
     Break-in prevention functions (RC2 / RC3)

Reliable and durable locking system


Profile systems PSF all glass configuration
10 mm glass    − − Secure unlocking mechanism

PSA narrow framed configuration


6, 8 and 10 mm glass, vertical interlocking     − Simple and intuitive operation whenever a function needs
to be reconfigured
PSXP standard
6 - 24 mm glass, vertical interlocking, EN16361-tested      Easy-to-use touchscreen display

PST thermally insulated AUTOMATIC-OPEN-EXIT-NIGHT-MANUAL-reduced opening


24 - 38 mm glass, double- or triple-glazed, EN16361-tested      Display of simple door information
RC2/RC3 burglar-resistant (PSXP/PST)
24 mm glass, P4A or P5A for PSXP
35 mm glass, double- or triple-glazed, PST
−   − −
Easy planning with myGilgen
Control pillar • Can be combined with PSA, PSF, PSXP, PST myGilgen supports you when it comes to advice, door
• All the control elements directly in the clear opening of the door configurations, price quotations and the processing of orders

   − − F ast and flexible planning of your door-related projects

T he www.mygilgen.com online platform

Optimal Possible − Impossible

You might also like